Control Measures Report

This document summarizes control measurements from an area on April 2, 2014. It includes the killing line speed, air chiller speed, washing water pressure, scalding steam pressure, and temperatures in various areas of the facility. Measurements were taken every 2 hours between 8 AM and 10 PM. The standard limits and notes section provides guidelines on temperature ranges and corrective actions needed. One unit was noted as not working and needing defrost, but was not yet fixed.

Uploaded by

Yasser Hassan
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
40 views4 pages

Control Measures Report

This document summarizes control measurements from an area on April 2, 2014. It includes the killing line speed, air chiller speed, washing water pressure, scalding steam pressure, and temperatures in various areas of the facility. Measurements were taken every 2 hours between 8 AM and 10 PM. The standard limits and notes section provides guidelines on temperature ranges and corrective actions needed. One unit was noted as not working and needing defrost, but was not yet fixed.

Uploaded by

Yasser Hassan
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 4

Control MeasuresReport

AREA Date 4/2/2014 80 Killing Line Speed Air Chiller Speed Washing Water Presure Scalding Steam Presure Scalding
Air Chiller Chicken inside temp
Fresh Store Truck Fresh Store Blast Frezer frozen store near to B.Freezer Frozen Store NO 1 Frozen Store NO 2 Receving Area Processing Area Portion Area Packaging Area Ladies packing Loading Area

unit

Standard limits min max

TIME
8.00 10.00 12.00 2.00 4.00

notes

bird/min bird/min Bar Bar C C C C C C C C C C C C C C C

80 80 0.5 0.5 53
-0.5 2
0 0 -35 -16 -16 -16 15 15 2 2 2 2

85

80

80

80

80

80

85 PresureParameters 1 1 ` 60
4
4 4 4 -40 -20 -20 -20 24 24 10 10 10 10 59.1 -0.9 STILL 0.7 OFF -14.2 -17 -10 -17.8 23.1 23 11.4 11 OFF N COMMENTS 59 6.3 9 1.9 OFF -2.6 -17.6 -10 -17.9 22.5 23.2 3.5 8 OFF N 58.9 9 10.7 2 7 -8.8 -19.2 -8.8 -15.6 21.1 22.3 4 9 OFF N 59 8.7 10.1 1.9 10 -3 -14.1 -9.5 -15.9 21.3 22.2 8 6 OFF N ONE UINT DOESN,T WORK ALWAYS NEED DEFROST NOT FIXED YET NOT FIXED YET

1- Temperature should be recorder every 2 hours 2- chilled product temp +3C corrective action if more then +4 C 3- frozen product temp. -18C corrective action if more then -16C