Contact Conductance of Typical Surfaces.: Table 2-3

This document contains a table listing the contact conductance of various metal surfaces under different conditions. The table includes the type of metal surface, its roughness, temperature, pressure, and heat transfer coefficient. It also provides data on stainless steel, aluminum, and copper surfaces both grounded and milled, in air and vacuum, with varying roughness and a range of temperatures and pressures.

Uploaded by

bamarpp
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views1 page

Contact Conductance of Typical Surfaces.: Table 2-3

This document contains a table listing the contact conductance of various metal surfaces under different conditions. The table includes the type of metal surface, its roughness, temperature, pressure, and heat transfer coefficient. It also provides data on stainless steel, aluminum, and copper surfaces both grounded and milled, in air and vacuum, with varying roughness and a range of temperatures and pressures.

Uploaded by

bamarpp
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

CHAPTER 2

Steady-State ConductionOne Dimension

Table 2-3 Contact conductance of typical surfaces.


1/hc
Surface type
416 Stainless, ground, air
304 Stainless, ground, air
416 Stainless, ground, with
0.001-in brass shim, air
Aluminum, ground, air
Aluminum, ground, with
0.001-in brass shim, air
Copper, ground, air
Copper, milled, air
Copper, milled, vacuum

Roughness
in m

Temperature,
C

Pressure,
atm

h ft2 F/
Btu

m2 C/W 104

100
45
100

2.54
1.14
2.54

90200
20
30200

325
4070
7

0.0015
0.003
0.002

2.64
5.28
3.52

100
10
100

2.54
0.25
2.54

150
150
150

1225
1225
12200

0.0005
0.0001
0.0007

0.88
0.18
1.23

50
150
10

1.27
3.81
0.25

20
20
30

12200
1050
770

0.00004
0.0001
0.0005

0.07
0.18
0.88

Designating the contact area by

and the void area by

, we may write for the heat