Calculation Flow and Calculator
Calculation Flow and Calculator
0.530
0.500
1.600
2.345
1.575
265
CALCULATED
Pressure load on diaphragm (lb)
Sealing Area, Aa (in2)
Valve/Poppet Area, Ap (in2)
Sealing/Poppet Delta, Adsp (psid)
Diaphragm Area, Ad
Spring Rate (lb/in)
0.812
55.710
0.620
9.24
0.095
150.0
50.0
Flow Calculator
Main Orifice Diameter
Flow Coefficient
Upstream Temperature (F)
Gas Density, Standard (lbm/ft3)
= 0.0749 (Air)
= 0.1034 (Argon)
= 0.0103 (Helium)
= 0.00521 (Hydrogen)
= 0.0724 (Nitrogen)
= 0.0828 (Oxygen)
Gas Constant (ft lb /lbm /R)
= 53.34 (Air)
= 38.65 (Argon)
= 386.0 (Helium)
= 766.4 (Hydrogen)
= 55.15 (Nitrogen)
= 48.28 (Oxygen)
Upstream Gas Ratio of specific heats
0.705
0.55
70
0.0749
53.34
1.400
Spring Information
"A" Spring
"B" Spring
"C" Spring
Psi
0-50
0-125
0-250
Free Length
Rate
1.575
265
1.575
585
1.575 1825
CALCULATED
a, Adsp (psid)
ssure @ Flow
152.79
0.221
0.196
-0.024
3.056
265.00
16.00
320.71
100
#REF!
-0.79
10.00
40.00
20.00%
4.40
354
21,224
0.211
164.70
64.70
530.00
0.53
0.84
32.17
4GDR-500B-V-A
60
50
40
30
20
10
0
0
1,000
2,000
3,000
4,000
5,000
5/18/2000
Nitrogen
68 Degrees Fairenheit
4GDR-500B-V-A
150.0 Psi
50.0 Psi
Set @ 1 SCFM Flow
52.2
Inlet
Outlet
150
150
150
150
150
150
150
150
150
150
Flow (SCFH)
50.0
47.3
46.6
46.0
45.8
45.5
45.1
45.0
45.0
45.0
0
764
1,200
1,620
2,000
2,395
2,825
3,210
2,585
3,880
Flow (SCFM)
10% Droop Line
0.00
45
0
12.73
45
20000
20.00
27.00
33.33
39.92
47.08
53.50
43.08
64.67
6,000
150
150
150
150
150
45.0
45.1
45.3
45.5
46.3
4,210
4,590
4,910
4,175
5,520
70.17
76.50
81.83
69.58
92.00
4GDR-500B-V-B
125
100
75
50
25
0
0
1,000
2,000
3,000
4,000
5,000
5/18/2000
Nitrogen
68 Degrees Fairenheit
4GDR-500B-V-B
200.0 Psi
100.0 Psi
Set @ 1 SCFM Flow
102.2
Inlet
Outlet
200
200
200
200
200
200
200
200
200
200
200
Flow (SCFH)
100.0
96.2
95.2
94.0
93.5
93.2
92.6
92.2
91.8
91.5
91.2
0
655
1,440
1,580
1,935
2,410
2,775
3,225
3,620
3,975
4,350
Flow (SCFM)
10% Droop Line
0.00
90
0
10.92
90
20000
24.00
26.33
32.25
40.17
46.25
53.75
60.33
66.25
72.50
6,000
200
200
200
200
200
90.8
90.5
90.5
90.2
90.0
4,710
5,035
5,340
5,680
5,880
78.50
83.92
89.00
94.67
98.00
4GDR-500B-V-C
200
150
100
50
0
0
5,000
10,000
Outlet
300
300
300
300
300
300
300
300
300
300
Flow (SCFH)
200.0
195.1
193.7
192.7
191.8
191.1
190.4
189.8
189.3
188.8
0
635
1,120
1,560
1,945
2,345
2,710
3,110
3,475
3,845
Flow (SCFM)
10% Droop Line
0.00
180
0
10.58
180
20000
18.67
26.00
32.42
39.08
45.17
51.83
57.92
64.08
15,000
300
300
300
300
300
300
300
300
300
300
300
300
300
188.5
188.1
187.8
187.5
187.1
186.4
186.3
186.4
186.5
186.3
185.0
184.5
183.0
4,150
4,475
4,825
5,100
5,420
5,835
6,270
6,395
6,520
6,895
8,780
9,770
12,950
69.17
74.58
80.42
85.00
90.33
97.25
104.50
106.58
108.67
114.92
146.33
162.83
215.83
0.710
0.687
2.200
3.400
2.750
405
CALCULATED
Pressure load on diaphragm (lb)
Sealing Area, Aa (in2)
Valve/Poppet Area, Ap (in2)
Sealing/Poppet Delta, Adsp (psid)
Diaphragm Area, Ad
Spring Rate (lb/in)
1.585
18.300
0.775
9.24
0.039
150.0
50.0
Flow Calculator
Main Orifice Diameter
Flow Coefficient
Upstream Temperature (F)
Gas Density, Standard (lbm/ft3)
= 0.0749 (Air)
= 0.1034 (Argon)
= 0.0103 (Helium)
= 0.00521 (Hydrogen)
= 0.0724 (Nitrogen)
= 0.0828 (Oxygen)
Gas Constant (ft lb /lbm /R)
= 53.34 (Air)
= 38.65 (Argon)
= 386.0 (Helium)
= 766.4 (Hydrogen)
= 55.15 (Nitrogen)
= 48.28 (Oxygen)
Upstream Gas Ratio of specific heats
0.710
0.55
68
0.0724
55.15
1.400
Spring Information
"A" Spring
"B" Spring
"C" Spring
"D" Spring
Psi
Free Length
Rate
0-50
2.750
405
0-125
2.700 1070
0-200
2.600 1960
0-250
2.400 3400
CALCULATED
a, Adsp (psid)
ssure @ Flow
307.88
0.396
0.371
-0.025
6.158
405.00
15.54
423.30
100
1.50
-0.41
2.71
47.29
5.41%
1.83
150
9,000
0.088
164.70
64.70
528.00
0.53
0.81
32.17
Pressure (PSI)
200
150
100
50
0
0
10
15
Turns
"A"
Number of Turns
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
"A"
0.0
3.0
5.9
9.0
12.1
15.1
18.2
21.4
24.6
27.9
31.3
34.6
37.9
41.5
44.5
48.2
51.8
55.4
58.9
62.8
"B"
0.0
7.7
15.2
22.9
30.6
38.5
46.3
54.3
62.2
70.2
78.3
86.4
94.5
102.6
110.6
118.9
127.2
135.6
143.5
153.5
"B"
"C"
0.0
13.5
28.8
44.4
60.1
75.5
91.1
106.8
123.0
139.8
156.9
173.6
191.2
209.2
227.1
"C"
20
4GDR-1000B-V-A
60
50
40
30
20
10
0
0
5,000
10,000
15,000
Outlet
150
150
150
150
150
150
150
150
150
Flow (SCFH)
50.0
49.9
50.0
49.8
49.9
49.9
49.9
49.7
49.6
0
660
1,110
1,605
1,980
2,420
2,380
3,000
3,525
Flow (SCFM)
10% Droop Line
0.00
45
0
11.00
45
20000
18.50
26.75
33.00
40.33
39.67
50.00
58.75
20,000
150
150
150
150
150
150
150
150
150
150
150
150
150
150
49.7
49.5
49.4
49.3
49.3
49.2
49.2
49.3
49.3
49.3
49.3
49.0
48.5
48.0
3,960
4,265
4,650
5,040
5,330
5,675
5,990
7,550
8,100
8,300
8,450
13,450
14,975
15,739
66.00
71.08
77.50
84.00
88.83
94.58
99.83
125.83
135.00
138.33
140.83
224.17
249.58
262.32
4GDR-1000B-V-B
125
100
75
50
25
0
0
5,000
10,000
15,000
Outlet
200
200
200
200
200
200
200
200
200
200
Flow (SCFH)
100.0
99.2
99.5
99.0
99.0
99.0
99.0
98.9
98.8
98.8
0
680
1,100
1,560
1,950
2,400
2,820
3,250
3,610
3,990
Flow (SCFM)
10% Droop Line
0.00
90
0
11.33
90
20000
18.33
26.00
32.50
40.00
47.00
54.17
60.17
66.50
20,000
200
200
200
200
200
200
200
200
200
200
200
200
200
200
98.5
98.6
98.4
98.4
98.5
98.4
98.4
98.2
98.1
97.9
97.5
97.0
96.5
96.0
4,410
4,630
4,955
5,310
5,700
6,000
6,270
6,440
6,560
6,750
7,600
11,000
12,900
15,500
73.50
77.17
82.58
88.50
95.00
100.00
104.50
107.33
109.33
112.50
126.67
183.33
215.00
258.33
4GDR-1000B-V-C
200
150
100
50
0
0
5,000
10,000
15,000
Outlet
300
300
300
300
300
300
300
300
300
300
Flow (SCFH)
200.0
198.3
198.1
197.7
197.6
197.5
197.5
197.3
197.1
197.0
0
735
1,125
1,600
1,995
2,390
2,760
3,140
3,465
3,810
Flow (SCFM)
10% Droop Line
0.00
180
0
12.25
180
20000
18.75
26.67
33.25
39.83
46.00
52.33
57.75
63.50
20,000
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
197.0
196.9
196.7
196.4
196.3
196.1
195.9
195.9
195.7
195.7
195.0
194.5
194.0
193.5
193.0
192.5
192.0
4,125
4,450
4,760
5,080
5,330
5,700
6,025
6,340
6,500
6,800
7,650
8,800
10,000
10,600
12,100
13,700
15,500
68.75
74.17
79.33
84.67
88.83
95.00
100.42
105.67
108.33
113.33
127.50
146.67
166.67
176.67
201.67
228.33
258.33
Instructions
Fill in Orifice Size. (List of Generant Orifices on sheet 2)
Fill in Discharge Coeficient. (List of Generant Kd on sheet 2)
Fill in Upstream Pressure, Downstream Pressure and Temperature.
Fill in "Yes" for CO2 Applications, or N/A.
Select Gas Density, Gas Constant and Gas Ratio
Read
Calculated Flow in blue boxes
Remarks:
INPUT
CALCULATED
0.05
267.70
14.70
530.00
0.53
1.32
32.17
0.22
13.49
809.24
186.29
11,177.36
N/A
HPRV Data
Orifice Diameter Flow Coeficient Kd Orifice Diameter
Configuration
0 - 1200
1,200 - 2400
HPRV
0.275
0.27
0.250
HPRVA
0.275
0.65
0.250
HPRV
0.515
0.20
0.275
HPRVA
0.515
0.35
0.275
HPRV
0.735
0.45
0.515
Size
1/4"
1/4"
1/2"
1/2"
3/4"
Kd
0.62
0.53
0.54
0.61
0.76
0.76
0.67
0.61
0.48
Kd
0.59
0.59
0.59
0.54
0.42
0.35
0.25
0.12
0.18
Part Number
CV-125
CV-250
CV-375
CV-500
CV-750
CV-1000
CV-1250
CV-1500
CV-2000
Cv
1.71
3.03
3.87
7.38
11.40
14.20
26.80
26.80
51.00
ICV-125
ICV-250
ICV-375
ICV-500
ICV-750
0.35
0.85
1.25
1.75
3.50
Flow Coeficient Kd
N/A
N/A
0.27
0.65
0.20
Generant P/N:
INPUT
Upstream Pressure, P1 (psig)
160
Downstream Pressure, P2 (psig)
150
CV
4.74
Specific Gravity (Water 1.0)
1.00
= 1.00 (Water)
= 0.83 (Hyd Oil,Mil 5606)
= 0.75 (Gasoline)
CALCULATED
Flow (GPM)
Upstream Pressure, P1 (psia)
Downstream Pressure, P2 (psia)
15
175
165
Cv Calculator
Rev A
Generant P/N:
INPUT
CALCULATED
Cv
Temperature (R)
Upstream Pressure, P1 (psia)
Downstream Pressure, P2 (psia)
Cv
1.000
0.200
Flow Coeficient Cd
Diameter
0.595
Area
Diameter
Lift
0.500
0.127
6.4233
530.0
114.700
109.700
17.95
0.8
Area Calculator
For Sharp Edge
0.28
0.200
Pressure Conversion
Rev A
INPUT
Enter Pressure (PSI)
CALCULATED
435.41
INPUT
Enter Inches
CALCULATED
0.3700
Enter Millimeters
3.50
Millimeters
Centimeters
Meters
Feet
9.40
0.94
0.09
0.0308
Inches
INPUT
Enter Degrees Fahrenheit
12,065.31
886.50
306,139.33
30,613.93
30.61
30.00
30,021.77
3,002,177.07
3,002.18
0.138
CALCULATED
70.00
Degrees Celcius
Degrees Kelvin
Degrees Ranken
21.11
294.26
529.60
Gases
INPUT
Enter Flow Rate (SCFM)
CALCULATED
61.58
52.34
49.88
52.96
165.65
233.39
62.81
49.88
58.50
Liquids
INPUT
Enter Flow Rate (GPM)
1.00
60.00
3.79
227.10
Interpolation
INPUT
Enter Scale Low
Enter Scale High
Enter Value Low
Enter Value High
Enter Value Sought
Atm
Psi
torr
Micron
In Hg
CALCULATED
20.00
30.00
2038.00
3524.00
2550.00
Scale Reading
23.45
1.0000
14.7000
0.0013
######
29.92
Area
INPUT
CALCULATED
Enter Diameter
Number of Holes
Percentage Exposed
Pressure
0.228
1
100.00%
100.000
1602.136
Area
0.041
Force
4.083
Flow in Lbs/s
2.00
100
50
10
Cubic Feet
Desired Pressure Psia
Flow Rate SCFM
Calculated
13.37
64.68
4.55
Seat Stress
For Sharp Edge
Orifice Dia
0.410
Seal OD Dia 0.437
Inlet Pressure 50.00
0.4235
0.1409
0.0180
7.84
0.1320
392
SCFH
LPM
LPH
CC/Min
CC/Hr
"=MM/Min"
25.02453
Gal/Hr
L/Min
L/Hr