MAGNETIC PARICLE EXAMINATION REPORT
CLIENT PROJECT JOB NO : LINE NO: DRAWING NO : ACCEPTANCE STANDARDS : ASME B31.3, ASME SECTION V Article 7 SURFACE CONDITION MATERIAL : As welded PROCEDURE NO : VIEWING CONDITION : Normal : N/A : : REPORT NO: 01 DATE:
API 5L GR B 283 Gr. C : ASTM
TECHNIQUE: ASME SEC V, Art 7 Wet Spray Method DEMAGNETIZATION TYPE OF EQUIPMENT : PERMENANT MAGNET
MAGNET LIFING POWER : 40 LBS ( 18 KG ) ILLUMINATION TYPE : NATURAL / ARIFICAL
ILLUMINATION LEVEL : 1000 LUX TEMPERATURE DURING TEST : ATM. TEMP CONSUMABLES CONTRAST PAINT MANUFACTURER Magna Flux
TYPE / Brand WCP-2
Batch No
TEST MEDIUM
Magna Flux
7HF
JOINT NO'S:
WELD LOCATION
SIZE & Thk.
WELDER NO.
RESULT
REMARKS: The above welding locations final MPT was carried out and found satisfactory results.
CONTRACTOR
Name: Signature: Date: