Bill of Quantity Grounding Protection: No. Area L W Total Lenght Conductor Number of Rods Meter Meter Meter Ea

This document contains a bill of quantities for grounding and lightning protection systems for 10 buildings. It lists the area, conductor length, number of rods, and number of air terminals for each building. The areas range from 10 to 30 square meters. The total conductor lengths range from 100 to 360 meters. The number of grounding rods ranges from 16 to 52. The number of air terminals ranges from 10 to 18.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views2 pages

Bill of Quantity Grounding Protection: No. Area L W Total Lenght Conductor Number of Rods Meter Meter Meter Ea

This document contains a bill of quantities for grounding and lightning protection systems for 10 buildings. It lists the area, conductor length, number of rods, and number of air terminals for each building. The areas range from 10 to 30 square meters. The total conductor lengths range from 100 to 360 meters. The number of grounding rods ranges from 16 to 52. The number of air terminals ranges from 10 to 18.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Bill Of Quantity Grounding Protection

Conductor No. Area LAREA meter 1 2 3 4 5 6 7 8 9 10 Control Building MCC Building Power Generator Building Mechanical Work Shop E & I Work Shop Warehouse Flammable Building Non Flammable Building Sulfur Building Hazardous Building 30 25 25 10 10 20 20 20 30 30 WAREA meter 20 31 31 20 20 20 20 20 24 30 Total Lenght Conductor meter 200 224 224 260 260 360 360 360 204 200 Number of Rods ea 16 16 16 52 52 56 56 56 16 16

Bill Of Quantity Lightning Protection Conductor


No. Area LAREA meter 1 2 3 4 5 6 7 8 9 10 Control Building MCC Building Power Generator Building Mechanical Work Shop E & I Work Shop Warehouse Flammable Building Non Flammable Building Sulfur Building Hazardous Building 30 25 25 10 10 20 20 20 30 30 WAREA meter 20 31 31 20 20 20 20 20 24 30 Total Lenght Conductor meter 100 224 224 60 60 160 160 160 216 200 Number of Rods ea 16 16 16 100 100 100 16 16 16 16

Air Terminal
No. Area LAREA meter 1 2 3 4 5 6 7 8 9 10 Control Building MCC Building Power Generator Building Mechanical Work Shop E & I Work Shop Warehouse Flammable Building Non Flammable Building Sulfur Building Hazardous Building 30 25 25 10 10 20 20 20 30 30 WAREA meter 20 31 31 20 20 20 20 20 24 30 Number of Air Terminal ea 18 14 14 10 10 12 12 12 16 16 Lenght of Each Air Terminal meter 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5 0,5