Monitoring Relays
Monitoring Relays
These relays are best suitable for monitoring balanced or unbalanced supplies, either of single phase, 3-phase 3-wire or 3-phase 4 wire loads powered by generators, UPS, stabilizers, inverters, or Mains (by Electricity Boards / Utilities); in AMF panels, PCCs, distribution boards and for power monitoring of individual loads / motors / pumps.
MODELS D1 VCR1, D1 VCR2 VCT D2, VCF D2, D2 VCT1, D1 VCT1, S2 VMR 4, S2 VMR 5, D2 EFR1, F3 EFR 1, OCS D1, S2 CMR2, S2 CMR3, S2 CMR4, OFS D1, S2 FMR1, RPT D2, RPF D2, CBCT, CT
FEATURES
Fixed/adjustable under/Over trip settings for parameters. Fixed/adjustable trip delays and Power On delays Built-in or external power supply Resetting Auto or Manual Output contacts : 1 CO or 2 CO Choice of enclosures (DIN-Rail, Flush) Models with Micro-Controller based design Use of SMD Technology User-friendly LED indications
PROTECTIONS / FUNCTIONS
Under/Over Voltage, Under/Over Current Under/Over Frequency Reverse Power Earth Fault/Ground Fault Earth leakage
Ordering Instructions
Product Family Name Model Name System Supply Voltage & frequency Aux. Supply/Control supply voltage Current input (1A or 5A)
17
D1 VCR1
D1 VCR2
VCT D2
VCF D2
Single Phase Under & Over voltage, Auto Reset, Adjustable under / over voltage settings, 2 CO output relay.
Single Phase Under & Over voltage, Auto Reset, Adjustable under/over voltage settings, 2 CO output relay
3-Phase 3-Wire Under & Over voltage Auto/Manual Reset, Adjustable under/over voltage settings, adjustable trip delay & ON delay, 2 CO output relay
3-Phase 4-Wire Under & Over voltage Auto/Manual Reset, Adjustable under/over voltage settings, adjustable trip delay & ON delay, 2 CO output relay
220/240 VAC,(+20%,-25%), 50/60 Hz3% 2 CO 165 V to 225 V (in step of 15) (2%) 2 CO
Over Voltage
Trip Time Delay Power on Delay Reset Weight Dimensions (mm) Overall (L x W x D) Mounting
2- 5 Sec (Fixed) (UV/OV) Auto Reset 180 gms. 76 x 30.5 x 117.5 68 mm centre to centre / 35 mm rail mounting
3.5 sec. (1.5 sec.) 3 min.( 20 sec) Auto Reset 180 gms. 76 x 30.5 x 117.5 68 mm centre to centre / 35 mm rail mounting
1-10 secs. (adjustable) 1-10 secs. (adjustable) Auto / Manual 450 gms. 76 x 56.5 x 117.5 67 x 46 / 35 mm rail mounting
1-10 secs. (adjustable) 1-10 secs. (adjustable) Auto / Manual 450 gms. 76 x 56.5 x 117.5 67 x 46 / 35 mm rail mounting
OV SET OV RESET
OV SET OV RESET
3 Ph
UV RESET
1 Ph N
UV RESET
UV SET TD 2 to 5sec. TD
TRIP DLY 2 to 5Sec.
UV SET
TD 1 to 10sec.
TD
13
14
2
P.ON DLY= 180 Sec.
Reset DLY= 180 Sec.
Reset DLY= 180 Sec.
13
14
16
17
T on
1 to 10sec.
13
15
13
15
16
18
L N
OFF ON
L O A D
L N
L O A D
R Y B
OFF
ON
L O A D
OFF
R Y B N
D1 VCR1
1
L O A D
OFF
N/V
N/V
D1 VCR2
1
N/V
ON
1 2 3 4 5 6
D1 VCR1
7
8
1 2 3 4 5 6
VCF D2
A/M LINK
N/V
ON
VCT D2
9
A/M LINK
13 14 15
7 8 9 10 11 12
13
7 8 9 10 11 12
14
15
13 14 151617 18
13 14 151617 18
D1 VCT1
D2 VCT1
S2 VMR4
S2 VMR5
US
US
US
3-Phase 3-Wire Under & Over Voltage, Auto reset, Adjustable UV/OV settings, fixed trip delay, 2 CO output relay.
3-Phase 3-Wire and 3-Phase 4-Wire (selectable) Under & Over voltage, Microcontroller based design, Auto/Manual Reset, Adjustable under/over voltage settings, Absolute values for UV/OV, adjustable trip delay & ON delay, 2 CO output relay (or selectable 1CO for UV, 1CO for OV) Failsafe-non-failsafe selectable
3-Phase 3-Wire Under & Over voltage, Microcontroller based design, SMD Technology Auto/Manual Reset, Adjustable under/over voltage settings, Absolute values for UV/OV, adjustable trip delay & ON delay, 2 CO output relay (or selectable 1CO for UV, 1CO for OV) Failsafe-non-failsafe selectable
3-Phase 4-Wire Under & Over voltage, Microcontroller based design, SMD Technology, Auto / Manual Reset, Adjustable under/over voltage settings, Absolute values for UV/OV, adjustable trip delay & ON delay, 2 CO output relay (or selectable 1CO for UV, 1CO for OV) Failsafe-non-failsafe selectable
100-120/220-240/380-440 V AC, 48-63Hz 2 CO 75-115 Unit of 100-120 V AC 165-225 Unit of 220-240 V AC 285-425 Unit of 380-440 V AC
3.51.5 Sec (UV/OV) Auto Reset 200 gms. (Approx). 76 x 30.5 x 117.5 68 centre to centre / 35 mm rail mounting
1-10 Sec (Variable) UV/OV/NF 1-10 Sec (Variable) Auto/ Manual Reset 300 gms (Approx.) 76 X 56.5 X 117.5 67 x 46 / 35 mm rail mounting
1-10 Sec. (Variable) 1-10 Sec (Variable) Auto / Manual Reset 110 gms (Approx.) 90 X 35 X 60 35 mm Rail Mounting
1-10 Sec. (Variable) 1-10 Sec (Variable) Auto / Manual Reset 110 gms (Approx.) 90 X 35 X 60 35 mm Rail Mounting
OV SET
OV SET OV RESET
OV SET OV RESET
OV SET OV RESET
OV RESET
3 Ph
UV SET
UV RESET
3 Ph N
UV RESET
3 Ph
UV RESET
3 Ph N
UV RESET
TD 3.5 sec.
TD
UV SET
TD 1 to 10sec.
UV SET
UV SET
TD
TD 1 to 10sec.
TD
TD 1 to 10sec.
TD
13
14
13
14
16
17
T on
1 to 10sec.
10
11
T on
1 to 10sec.
10
11
T on
1 to 10sec.
13
15
13
15
16
18
10
12
10
12
L O A D
L O A D N
3 or 4 Wire selection link
R Y B
L O A D
R Y B N
L O A D
OFF
DOL STARTER
D2 VCT1
Relay position shown in Power off condition Note: S2 Series - RoHS Product available on request.
19
S2 CMR2
1 Phase Current Monitoring Relay
US
Single phase over current Auto reset, Input 1A or 5 A through CT, Adjustable over current trip settings, Adjustable trip delay, 1 CO output relay
Single phase under & over current Microcontroller based design, SMD technology, Auto/Manual reset, Input 1A or 5 A through CT, Adjustable under / over current trip settings, adjustable trip delay & ON delay, 2 CO output relay (or selectable 1CO for UC, 1CO for OC) Failsafe-non-failsafe mode selectable
Trip setting EF Trip Setting Under Current Over Current Power On Delay Trip Time Delay Resetting Weight Dimensions (mm) Overall (L x W x D) Mounting (L x W) N.A.
50% -140% (adjustable) of CT sec
10% - 100% (Variable) Of CT Sec. 50% - 140% (Variable) Of CT Sec. 1-10 Sec. (Adjustable) 1 Sec. 1-10 Sec. (Adjustable) 1 Sec. Auto / Manual 140 gms 90 X 35 X 60 35 mm Rail Mounting
3.5 secs 1.5 sec (fixed) 1 - 10 secs (adjustable) Auto 250 gms. 76 x 30.5 x 117.5 68mm centre to centre / 35mm rail Mounting
OC Reset
OC Reset UC Reset
Current Input
Current Input
T ON 2 to 5 sec. 13 13 14 15
Td 1 to 10 sec.
7 7 8 10 11 12
T ON 1 to 10 sec.
AUTO RESET
Td 1 to 10 sec.
9 10
L
N
BUSBAR TRIP COIL C.B. RELAY CONTACTS C.T. RELAY COIL FAULT A CIRCUIT TO BE PROTECTED
Interlocking circuit is required for shunt trip coil as shunt coil require pulse only for tripping, incase of contineous power shunt coil burns.
L O A D
L O A D
BATTERY
TRIP COIL
1 2 3
OCS D1
N/V
DOL STARTER ON OFF
AUX. SUPPLY
7 8 9
13 14 15
20
Relay contact position shown in 'Power off' condition Note: S2 Series - RoHS Product available on request. CCS D2 Model Available on request.
F3 EFR1
Earth Fault Relay
S2 CMR3
Ground Fault Relay
S2 CMR4
Earth Leakage Relay
New
US
US
Earth fault/Ground fault monitoring of 3 phase systems Manual Reset, Input 1A or 5A through CBCT, Adjustable earth fault trip setting, adjustable trip delay, 2 CO relay output
Earth fault/Ground fault monitoring of 3 phase systems Manual Reset, Input 1A or 5A through CBCT, Adjustable earth fault trip setting, adjustable trip delay, 2 CO relay output
Earth fault/Ground fault monitoring of 3 phase systems, Microcontroller based design, SMD technology, Manual Reset, Input 1A or 5A through CBCT, Adjustable earth fault trip setting, Adjustable trip delay & ON delay, 2 CO relay output Failsafe-non-failsafe selectable
100-120/220-240/415 V AC 20%, 48-63 Hz 100-120/220 -240 / 415 V AC / 24V DC 20% 1A or 5A (Selectable) CBCT Secondary 2 CO
10% - 100 % (adjustable) of CT sec
Earth leakage monitoring of 3 phase systems, Microcontroller based design, SMD technology, Manual Reset, Input through CBCT, Adjustable trip setting, Adjustable trip delay & ON delay, 2 CO relay output Failsafe-non-failsafe selectable
100-120/220-240/415 V AC 20%, 48-63 Hz 100-110/240 / 415 V AC / 24V DC 20% 300mA CBCT Secondary 2 CO
10% - 100 % (adjustable) of CT sec
24-30 VDC / 110-240 V AC / DC / 380-440 V AC 20% 24/30VDC10%,110/220/230/240VAC/DC 20% 380/415/440VAC 20%, 50Hz
N.A. N.A. N.A. 0.1-1.0 / 1-10 Sec. (Adjustable) Manual / Remote (Selectable) 550gms. 76 x 56.5 x 117.5 67 x 46 / 35 mm rail Mounting
N.A. N.A. N.A. 0.1-1.0 / 1-10 Sec. (Adjustable) Manual / Remote (Selectable) 550gms. 96 x 96 X 80 mm 92 X 92
N.A. N.A. 1 -10 Sec.(Adjustable) 0.1 - 1 Sec.(Adjustable) Manual 140 gms 90 X 35 X 60 35 mm Rail Mounting
N.A. N.A. 1 -10 Sec.(Adjustable) 0.1 Sec to 1 Sec.(Adjustable) Manual 140 gms 90 X 35 X 60 35 mm Rail Mounting
In
Td 13 13 14 15 16 16 17 18
Td
CBCT ( ZCT)
OFF ON
R Y B
N/V
L O A D
L O A D
R Y B
OFF ON
L O A D
N/V
1 2 3 4 5 6
AUX. SUPPLY
D2 EFR1
13 14 15 16 17 18
S2 CMR 4
7 8 9 10 11 12
Relay contact position shown in 'Power off' condition Note: S2 Series - RoHS Product available on request.
21
S2 FMR1
Frequency Monitoring Relay
US
Single phase over frequency, Auto reset, Adjustable over frequency trip settings,' Adjustable trip delay, 1 CO output relay
Single phase under & over frequency, Microcontroller based design, SMD technology, Auto reset, Adjustable under/over frequency trip settings, Adjustable trip delay & ON delay, 2 CO output relay Failsafe-nonfailsafe mode selectable
100-120/220-240/380-440 V AC 20%, 38-72 Hz In Built 1 CO + 1 CO / 2 CO 40 Hz - 60 Hz (Variable) 50 Hz - 70 Hz (Variable) 1 - 10 Sec.(Adjustable) 1 Sec. 1 - 10 Sec.(Adjustable) 1 Sec. Auto / Manual 130 gms 90 X 35 X 60 35 mm Rail Mounting
Supply Voltage System Auxiliary Ext. Input Output contact Trip setting Under Frequency Over Frequency
100-120 / 220-240 / 380-440 V AC 20%, 50Hz / 60 Hz 12 / 24 V DC or Built in 1 CO N.A. 50 Hz - 70 Hz 3.5 secs. 1.5 sec (fixed) 1 - 10 secs. (adjustable) Auto 450 gms. 76 x 30.5 x 117.5 68 centre to centre / 35 mm Rail Mounting
Reverse Power Power On Delay Trip Time Delay Resetting Weight Dimensions (mm) Overall (L x W x D) Mounting (L x W)
OF Reset
OF Reset UF Reset
Freq. Input
Freq. Input
T ON 2 to 5 sec. 13 13 14 15
Td 1 to 10 sec. 7 7 8 10 9 10 11 12
T ON 1 to 10 sec.
AUTO RESET
Td 1 to 10 sec.
L N
L O A D
L O A D
OFF
ON
OFF
ON
N/V
DOL STARTER
N/V
DOL STARTER
OFS D1
13
14
15
22
RPF D2
3-phase 3-wire generators reverse power monitoring Auto/Manual reset, Reverse power (current) trip settings adjustable, ON delay and trip delay adjustable, 2 CO output relay
Single phase or 3-phase 4-wire generators reverse power monitoring Auto/Manual reset, Reverse power (current) trip settings adjustable, ON delay and trip delay adjustable, 2 CO output relay
100-120 / 220-240 / 380-440 V AC 20% Built-in 5A CT Secondary & R,Y, B 2 CO 2% - 20% (adjustable) 1 - 10 secs. (adjustable) 1 - 10 secs. (adjustable.) Auto / Manual 460 gms. 76 x 56.5 x 117.5 67 x 46 / 35 mm Rail Mounting
100-120 / 220-240 / 380-440 V AC 20% Built-in 5A CT Secondary & B, Neutral 2 CO 2% - 20% (adjustable) 1 - 10 secs. (adjustable) 1 - 10 secs. (adjustable) Auto / Manual 460 gms. 76 x 56.5 x 117.5 67 x 46 / 35 mm Rail Mounting
POWER SOURCE
ASYN. MOTOR
POWER SOURCE
ASYN. MOTOR
3 Ph Supply Forward Power Reverse Power Recovery Level Current Tripping Level
RPT D2 / RPF D2
RPT D2 / RPF D2
13 13
14 16 15 16
17
Td 1 to 10 sec.
18
1 to 10 sec.
T ON
LOAD
ASYN. MOTOR
L O A D
RPF D2
A/M LINK
23