Ii2Geexiaiict6: Device Group Ignition Prote-Ction Class Temperature Class Explosion Group Category Identifier

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

ATEX General information

According to 94/9/EC, a device that is to be used in an environment at risk of explosion may only be brought into the market if it satisfies the standards specified in the norm. Compared with the previous directives, it must be noted that the specification refers not only to electrical but also to mechanical equipment (e.g. cylinders). Devices are divided into categories and groups to accurately define the conditions of use. This definition is marked on the device and may appear as follows:

Example:

II 2G EEx ia IIC T6
Category
(see page 12.001)

Device group Device group

Identifier

Ignition protection class

Explosion group

Temperature class

There are 2 groups of devices. Devices of Group I, Category M are for use in underground mines and their above ground equipment, which are at risk from firedamp and/or inflammable dusts. (This is not given further coverage in this document). All other areas at risk of explosion are combined in Device Group II.

Identifier
EEx defines that this is an electrical device.

Ignition protection class


This defines which measures are used to ensure explosion protection. The following ignition protection classes are used by AIRTEC: m = Encapsulation, ia = Intrinsic safety, c = Safe by design Other ignition protection classes are defined in EN 50014: 1997. The abbreviations are currently under review discussion. It should be noted that devices in ignition protection class ia may only be supplied from circuits that are certified to be intrinsically safe.

Explosion group
Device group II is sub-divided into Explosion Groups A, B or C. This classification is dependent on the typical material properties of the gases and vapors that occur. The hazard level of materials increases from Explosion Group IIA to IIC. The requirements for the devices increase accordingly. If a device is approved for IIC, it can be used for all other explosion groups. Alternatively, the chemical formula or the name of the material can be stated here.

Temperature class
It must be ensured that the ignition temperature of an inflammable material is not reached during operation. For this purpose, the maximum surface temperature of a device must be less than the minimum ignition temperature. For this reason, the maximum surface temperature of equipment for use with inflammable gases, vapors or mists is specified in temperature classes. For dusty environments, the maximum surface temperature is specified in C. Temperature class T1 T2 T3 T4 T5 T6 12.000 Maximum permissible surface temperature of the equipment (C) 450 300 200 135 100 85

Subject to change

ATEX General information


Category
The categories define which zones the devices may be used in. The classification states how frequently and in what concentration the ignitable mixture occurs. Furthermore, differentiation is made as to whether the hazard is due to gases, vapors and mists or due to dust.

Example of zone classification in gas Ex area.

Category 1
For devices, which guarantee a very high level of safety. Intended for the case where an atmosphere at risk of explosion is to be expected frequently or continuously. Devices in this category can also be used in Category 2 and 3.

Inflammable gases, vapors or mists


Zone 0 equivalent to Category 1G Area in which an atmosphere at risk of explosion as a mixture of air and inflammable gases, vapors or mists is continuously or frequently present or present for long periods.

Inflammable dusts
Zone 20 equivalent to Category 1D Area in which an atmosphere at risk of explosion in the form of a cloud of inflammable dust contained in the air is continuously or frequently present or present for long periods.

Category 2
For devices, which guarantee a high level of safety. Intended for the case where an atmosphere at risk of explosion is to be expected. Devices in this category can also be used in Category 3.

Inflammable gases, vapors or mists


Zone 1 equivalent to Category 2G Area in which an atmosphere at risk of explosion as a mixture of air and inflammable gases, vapors or mists can form occasionally during normal operation.

Inflammable dusts
Zone 21 equivalent to Category 2D Area in which an atmosphere at risk of explosion in the form of a cloud of inflammable dust contained in the air can form occasionally during normal operation.

Category 3
For devices, which guarantee a normal level of safety. Intended for the case where an atmosphere at risk of explosion is to be expected rather infrequently and, if so, for only short periods.

Inflammable gases, vapors or mists


Zone 2 equivalent to Category 3G Area in which an atmosphere at risk of explosion as a mixture of air and inflammable gases, vapors or mists does not normally occur at all or only for short periods during normal operation.
Subject to change

Inflammable dusts
Zone 22 equivalent to Category 3D Area in which an atmosphere at risk of explosion in the form of a cloud of inflammable dust contained in the air does not normally occur at all or only for short periods during normal operation. 12.001 1 2

ATEX
The following AIRTEC products are available in explosion-proof design for Device Group II in accordance with 94/9/EC. The following list is intended to provide an overview. Attention must be paid to the Operating Instructions and Declaration of Conformity before commissioning. These can be provided on request.

Electrically operated valves


Series Functions Classification Special features Valves are equipped with special actuators. Dimensional changes and technical data can be seen in the following pages. T Medium 10 C + 50 C T amb 10 C + 50 C Catalogue page 4.040 4.080 4.110 4.110 4.110 4.150 4.150 4.150 5.020 4.180 5.040 4.120 4.160 5.060 5.080 5.100

MS-18 310 II 2GD c T5 T 100 C M-04 310, 311, 320, 510, 511, 520, 530, 533, (II 3GD nA T5 T95 C 534 on request) M-05 310, 311, 320, 510, 511, 520, 530, 533, 534 ME-05 311, 320, 511, 520 MO-05 311 M-07 310, 311, 320, 510, 511, 520, 530, 533, 534 M0-07 311 ME-07 311, 320, 520 MG-07 510, 520, 530, 533 MN-06 310, 311, 320, 510, 511, 520, 530, 533 M-06 310, 311, 511 M-22 310, 510, 511, 520, 530, 533 KN-05 310, 311, 510, 520, 530, 533, 534 KM-09 510, 520, 530, 533, 534 KM-10 510, 520, 530, 533, 534 KME-10 520, 530 MI-01 510, 511, 520, 530, 533 MI-02 510, 520, 530, 533 MI-03 510, 520, 530, 533

Pneumatically operated valves


Series Functions P-04 P-05 P-06 P-07 P-12 L-25 L-28 PI-01 PI-02 PI-03 Example order Catalogue number page 311, 511, 530, 533, 534 II 2GD c T5 T 100 C Compressed air in P-04-311-ATEX accordance with 310, 311/2, 320, 510, 511, 3.060 ISO 8573-1: 2001 P-05-310-ATEX 520, 530, 533, 534 Class 74310, 311, 320, 510, 511, 520, P-06-310-ATEX T Medium 530, 533 10 C + 50 C 310, 311/2, 320, 510, 511, T amb P-07-310-ATEX 3.080 520, 530, 533, 534 10 C + 50 C 310, 311, 320, 510, 511, 520, P-12-310-ATEX 3.100 534 310, 311, 320, 510, 520 L-25-310-ATEX 3.020 310, 311, 320, 510, 511, 520 L-28-310-ATEX 3.040 510, 511, 520 PI-01-510-ATEX 510, 520, 530, 533, 534 PI-02-510-ATEX 510, 520, 530, 533, 534 PI-03-510-ATEX Classification Special features

Other series can be provided on request. 12.002


Subject to change

ATEX
Speed regulation plates for valves acc. to NAMUR
Series MN-063-DR MN-065-DR Classification II 2G c T5 10 C Tamb 50 C Operating conditions Example order number Catalogue page 5.026

Compressed air in accordance MN-063-DR-ATEX with ISO 8573-1: 2001 Klasse 74T Medium 10 C + 50 C T amb 10 C + 50 C

The following accessories are approved for the valves: Manifolds: R-281/n, R-283/n, R-181/n,R-183/n, Brackets: R-141/n, R-143/n, RF-05, RF-07 Modular manifolds: Hollow bolt: H-281, H-283, R-183, H-183, H-143, HI-143, HI-183 Blind plates: R-281-V, R-283-V, R-181-V, R-183-V, RF-09-V, RF-10-V, R-141-V, RF-04-V, RF-C-07-V, R-143-V, MG-07-V Seal plate:

R-281-W, R-181-W, R-141-W RF-09/n, RF-10/n, RF-19-E, RF-09-E1, RF-10-E1, RF-09-E2, RF-10-E2, RF-09-Z1, RF-10-Z1, RF-09-Z1, RF-10-Z1, RF-09-Z4, RF-10-Z4, RF-24, RF-C/n RF-19-01

Cylinders
Series XL Classification Operating conditions Example order number Catalogue page 8.020

II 2GD c T4 T 135 C Compressed air in accordance with XL-040-320-000-ATEX ISO 8573-1: 2001 Class 74At V i 1 m/s Class 744 T Medium 20 C + 50 C / T amb 20 C + 60 C Max permissible energy l 32 0,1 J, l 40 and 50 0,2 J, in the end positions: l 63 0,5 J, l 80 0,9 J, l 100 1,2 J, l 125 5 J

The following accessories are approved for the cylinders: Flexible coupling FK Rod eye FO and RO up to Vmax 1 m/s Rod clevis FD and RD Piston rod nut FE and RL

Cylinder fixings XLB- l -01, XLB- l -02, XLB- l -03, XLB- l -04, XLB- l -05, XLB- l -06, XLB- l -07, XLB- l -08, XLB- l -09, XLB- l -10, XLB- l -12

Rodless cylinders
Series ZX Classification II 2G T6 T 85 C, 10 C Tamb 60 C Operating conditions Compressed air in accordance with ISO 8573-1: 2001 Klasse 74V max 1 m/s T Medium 10 C + 50 C T amb 10 C + 60 C Example order number ZX-25-S-0500-01ATEX Catalogue page 9.140

The following accessories are approved for the cylinders: Head mount ZXB--01 Trunnion mount Head mount tall ZXB--02

ZXB--10

Proximity Sensors
Series ZS Classification II 3 GD EEx nA II T4 X IP 67 T 110 C Order number ZS-7300 ZS-7301 Catalogue page 8.221 1 2

Subject to change

12.003

Electrically operated valves in -proof design

Valves from the MS-18, M-05, M-07, MN-06 and KN-05 ranges can be provided in explosion proof design in accordance with 94/9/EC (ATEX) for device group II. For this purpose, special valves are equipped with alternative electrical equipment. The dimensional changes of these components, which are mounted on the valve housing, can be seen on the following pages. The valves are supplied in an assembled state, complete with valve, as the approval relates both to the electrical and the mechanical components. Individual parts may only be supplied for replacement purposes. When ordering, the number of the required design must be added to the valve order number, or the required version must be noted in the item text. Example 1: M-05-510-HN- Ex037-24V= Example 2: M-05-510-HN Solenoid valve 5/2-way G 1/8, explosion proof design Ex037 Control voltage 24V=. The specified technical boundary conditions are to enable the user to make a selection. The operating instructions for the valve and the electrical equipment must be taken into account before putting into operation. These are included with each valve and we would be pleased to send them to you on request by quoting Order No. 54- ATEX-01. Version Ignition protection class Classification Rated voltage Rated current Rated power Cable length Medium Temperature range Ambient Medium min. max. Ex037 Encapsulated with casting compound II 2G EEx m IIC T5 II 3D IP 65 T95 C 24 V DC 136 mA 3.3 W 230 V AC 14 mA 3.1 VA Ex038 Intrinsically safe II 2G EEx ia IIC T6 Supply only from certified intrinsically safe circuits with the following maximum values: U P 28 V I P 115 mA P P 1.6 W

3 m standard Compressed air in accordance with ISO-8573-1 : 2001 10 C + 50 C (with battery fitted 10 C + 50 C max. + 40 C) 10 C + 50 C Please observe the minimum valve operating pressure. 10 bar 8 bar

Pressure range

Order numbers for coils as spare parts Coils must only be used with the armature tubes provided for the intended purpose. Item number 23-SP-037-012-03 23-SP-037-012-05 23-SP-037-012-10 23-SP-037-027-03 23-SP-038-912 Voltage 24 V DC 24 V DC 24 V DC 230 V AC 24 V DC Cable length 3m 5m 10 m 3m Ignition protection class Encapsulated with casting compound Encapsulated with casting compound Encapsulated with casting compound Encapsulated with casting compound Intrinsically safe

12.004

Subject to change

Electrically operated valves in -proof design


Dimensional changes compared with standard valves due to Ex-specific components
MS-18 Ex037 MS-18 Ex038

1 = pressure inlet 2 = outlet 3 = exhaust

(7) = manual override (8) = solenoid coil can be repositioned 360

1 = pressure inlet 2 = outlet 3 = exhaust

(7) = manual override (8) = solenoid coil can be repositioned 360

M-05 Ex037

M-05 Ex038

(7) = manual override

(8) = solenoid coil can be repositioned 4 x 90

(7) = manual override

(8) = solenoid coil can be repositioned 4 x 90

M-07 Ex037

M-07 Ex038

1 2
(7) = manual override (8) = solenoid coil can be repositioned 4 x 90 (7) = manual override (8) = solenoid coil can be repositioned 4 x 90

Subject to change

12.005

Electrically operated valves in -proof design


Dimensional changes compared with standard valves due to Ex-specific components
MN-06 Ex037 MN-06 Ex038

(7) = manual override

(8) = solenoid coil can be repositioned 4 x 90

(7) = manual override

(8) = solenoid coil can be repositioned 4 x 90

M-22 Ex037

M-22 Ex038

(7) = manual override

(8) = solenoid coil can be repositioned 4 x 90

(7) = manual override

(8) = solenoid coil can be repositioned 4 x 90

KN-05 Ex037

KN-05 Ex038

(7) = manual override

(8) = solenoid coil can be repositioned 4 x 90

(7) = manual override

(8) = solenoid coil can be repositioned 4 x 90

12.006

Subject to change

You might also like