Steel Design: Project Job Number Engineer

The summary analyzes the steel section of a frame member and finds it to be overstressed. Key details include: - The frame member is located at X=14,300, Y=7,875, Z=1,377 with a length of 2,854m. - The design section is an L-75x75x6 brace. - The stress check shows the governing ratio is 0.379, exceeding the limit of 1.000, resulting in an error message of overstress. - Moment, axial force, shear, and torsion calculations are provided but the member is found to be over capacity in the governing ratio check.

Uploaded by

Rodrigo Speller
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
45 views

Steel Design: Project Job Number Engineer

The summary analyzes the steel section of a frame member and finds it to be overstressed. Key details include: - The frame member is located at X=14,300, Y=7,875, Z=1,377 with a length of 2,854m. - The design section is an L-75x75x6 brace. - The stress check shows the governing ratio is 0.379, exceeding the limit of 1.000, resulting in an error message of overstress. - Moment, axial force, shear, and torsion calculations are provided but the member is found to be over capacity in the governing ratio check.

Uploaded by

Rodrigo Speller
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SAP2000 Steel Design

Project
Job Number
Engineer

AISC-ASD89 STEEL SECTION CHECK


Combo : D+L
Units : KN, m, C

Frame
X Mid
Y Mid
Z Mid
Length
Loc

:
:
:
:
:
:

62
14,300
7,875
1,377
2,854
0,000

Design Sect:
Design Type:
Frame Type :
Sect Class :
Major Axis :
RLLF
:

Area
IMajor
IMinor
Ixy
Theta

:
:
:
:
:

8,640E-04
0,000
0,000
0,000
45,000

SMajor
SMinor
ZMajor
ZMinor

:
:
:
:

L-75x75x6
Brace
Moment Resisting Frame
Non-Compact
0,000 degrees counterclockwise from local 3
1,000

8,677E-06
8,677E-06
1,563E-05
1,563E-05

rMajor
rMinor
rMax
rMin

:
:
:
:

0,023
0,023
0,029
0,015

AVMajor:
AVMinor:
E
:
Fy
:

4,500E-04
4,500E-04
199947978,80
248211,284

DESIGN MESSAGES
Error: Section overstressed
STRESS CHECK FORCES & MOMENTS
Location
P
0,000
-2,253

M33
0,259

M22
0,000

V2
0,566

V3
0,000

T
0,000

PMM DEMAND/CAPACITY RATIO


Governing
Total
Equation
Ratio
(H1-3)
0,379

P
Ratio
0,094

MMajor
Ratio
0,093

MMinor
Ratio
0,192

Ratio
Limit
1,000

Status
Check
OK

AXIAL FORCE DESIGN


Axial

P
Force
-2,253

fa
Stress
2607,353

Fa
Allowable
27780,723

Ft
Allowable
148926,770

M
Moment
0,183
-0,183

fb
Stress
12995,665
28620,804

Fb
Allowable
139179,873
148926,770

Fe
Allowable
68598,960
27780,723

V
Force
0,566
0,000

fv
Stress
1258,481
0,000

Fv
Allowable
99284,514
99284,514

Stress
Ratio
0,013
0,000

MOMENT DESIGN
Major Moment
Minor Moment

Cm
Factor
1,000
1,000

K
Factor
1,000
1,000

L
Factor
1,000
1,000

Cb
Factor
1,000

SHEAR DESIGN
Major Shear
Minor Shear

SAP2000 v14.0.0 - File:C:\Users\Rodrigo\Desktop\Estrutura

Status
Check
OK
OK

T
Torsion
0,000
0,000

dezembro 30, 2013 1:27