Wind Load Calculations
Wind Load Calculations
: : : :
: : : :
Building Type
Length (o/o) Width (o/o) Width module Bay spacing Clear eave height Max. eave height Roof slope () Wt. of sheet & purline Dead Load (DL)
=
= = = = = = = = = 39.00 m 26.00 m 7.80 11.00 11.00 5.71 m m m DEAD LOAD (DL) 10.00 Kg/m 0.08 KN/m COLLATERAL LOAD
= =
= =
= =
= 39 m/s = Vbxk1xk2xk3 k1 = probability factor (risk coefficient) = 1 k2 = terrain, height and structure size factor = 0.98 k3 = topography factor = 1 Vz = 38.22 m/s
Terrain Category 2
Class B
= pz =
Encloser condition of the building = Enclosed Internal pressure coeff.(Cpi) = 0.20 h/w = 0.42 = h/w<=1/2 l/w = 1.50 = 1<l/w<=3/2 External pressure coeff.(Cpe) : Wind Angle () 0 degree 90 degree
Table 4 Coeff. For Wall Left Right 0.70 -0.25 -0.50 -0.50
Table 5 Coeff. For Roof Left Right -0.9350 -0.40 -0.80 -0.80
WIND LOAD DIAGRAMS:~ Wind Across the Ridge (With -Ve Cpi) -0.74 -5.02 KN/m -0.20 Wind Across the Ridge (With +Ve Cpi) -1.14 -7.759 KN/m -0.60 KN/m -4.10
-1.37KN/m
-6.84 KN/m
-4.10 KN/m
KN/m 0.00 -0.30 Note: 1) Values within the circles are the UDL 2) -Ve value means, load applied away from structure.