DESCRIPTION: Low voltage slip ring motors, type 2.ZPDI are manufactured according to IEC
standards. Motor frames are welded construction while stator end shields and bearing caps are of
cast iron. The motors are provided with increased power and increased efficiency factor.

STANDARDS: Motors type 2.ZPDI satisfy the following standards:
JUS IEC60034-1, 1994 Rating and performances
IEC 60034-5, 1991 Degree of mechanical protection
JUS IEC 60034-6,1997 Methods of cooling
IEC 60034 7, CODE II, 1992 Mounting arrangements
JUS IEC60034,8, 1972 Terminal markings
IEC 60034-9, 1990 Noise limits
JUS IEC 60034 11, 1992 Built-n thermal protection
JUS IEC 60034-14, 1992 Mechanical vibrations, limit values
IEC 60038, 1983 Standard voltages
IEC 60072, 1991 Mounting dimensions
JUS IEC 60085, 1993 Insulation material classification

The motors carry CE mark as a sign of product conformity to the requirements of all applicably
directives of European Union, especially concerning safety, life health protection, environment
protection and consumer protection:
Low voltage Directive 73/23 EEC, MODIFIED BY 93/68/EEC,
Electromagnetic Compatibility Directive 89/336/EEC modified by 92/31/EEC
Machinery Directive 89/392/EECmodified by 91/368/EEC, 93/44/EEC and 93/68/EEC.
Quality assurance system of SEVER motor factories is certified according to the international
standard JUS ISO 9001.
JUS IEC standards, which are referred to in these brochures, are identical with the corresponding
IEC standards.
VOLTAGE AND FREQUENCY: The motors are produced for the rated supply voltage 3 x 400 V
10 %, 50 Hz. On special request of the standards this motor can operate at supply voltages of
380 to 1000 V and at frequency of 40 to60 Hz.
Rotor voltages are in tolerance 10 %.

OUTPUT: Rated powers given in tables refer to continuous operation (drive type S1), ambient
temperature up to 40 C and altitude up to 1000 m. For special conditions of operation send us
your special inquiry.

SPEED: Rotation speed depends on the number of pole pairs. All motors are manufactured
normally according to the leaflet. Speeds are given in tables at normal frequency, nominal voltage
and rated output. On request the motors are delivered also with larger number of pole pairs, and
for smaller speeds than the given in the leaflet.

MECHANICAL PROTECTION: Motors are constructed as totally enclosed with mechanical
protection IP55, by which is disabled penetration of water jet into it.

MOUNTING ARRANGEMENTS: The motors are designed for the following mounting
arrangements: IM 1001 (IMB3) and IM 3011 (IMV1) for all shaft heights.

TOLERANCE: mechanical dimensions of electric motors and tolerances are in accordance with
the IEC 60072, and they are shown in the following table.

LOW VOLTAGE THREE-PHASE TOTALLY ENCLOSED MOTORS, INCREASED POWER, TYPE 2.ZPDI

2
Term Designation Size Tolerance
Shaft diameter D, DA >50 mm m6
Flange spigot diameter N >450 mm h6
Flange pitchdiameter M >500 mm 1,00 mm
Footfixing dimension A, B
>250 mm
>500 mm
1,0 mm
1,50 mm
Shaft height H >250 mm -1,00 mm

Electrical tolerances for the rated values and performances are in accordance with IEC 60034-1
and are shown in the following table :
Term Designation Dimensions Tolerance
Efficiency
PN 50 kW
PN > 50 kW
-0,15 (1-)
0,10 (1-)
Power factor cos
0,02 Min
07 , 0
,
6
cos 1
Max


Slip s
PN < 1 kW
PN 50 kW
30 %
20 %
Max. torque Tb - 10 %
Moment of
inertia
J 10 %

BEARINGS: Bearing arrangement is designed with additional lubrication during operation with
lithium grease and for temperature up to 40 C. Technical specification for bearing arrangement
are given in the following table:
Period of additional
lubrication [h]
Drive side
Opposite side of
drive end
Grease
quantity
Numberof poles
MOTOR
TYPE

Horizontal
design
Vertical
design
[g] [cm
3
] 4 6 8
2.ZPDI 315 NU 322 C3 6319 C3 7319 B 60/45 75/57
2400/
5200
3700/
8200
4900/
10800
2.ZPDI 355
2.ZPDI 400
NU 324 C3 6322 C3 7322 B 72/55 90/70
2200/
4300
3400/
7500
4400/
9500

COOLING: The motors are made with external surface ventilation (IC 411). The fan is its own
and is independent from the rotation sense because its blades are radial. In the rotor interior
there is an internal fan, which provides circulation of air from the interior, through the closed
channels on the frame..

WINDING INSULATION: the winding stator and rotor are designed in insulation class F, at
which the stator winding is impregnated two times in vacuum (VPI method), and the rotor
winding is impregnated by dipping. This system of insulation is suitable for temperature rise limit
of 105 K above the ambient temperature of 40 C. The motors type 2.ZPDI are designed in a
way that heating satisfies insulation class B, i.e. over temperature of the hottest space in the
motor does not exceed 80 K with ambient temperature of 40 C. .

ROTOR: Rotor is made with winding. The rotor winding is made as a three phase with copper
rods, which are connected by hard soldering, and is made with three terminals to the slip ring.

SLIP RING: Slip ring with three slip paths are on the drive end of the motor. They are made of
nickel-bronze and are isolated from the winding of stator and rotor with special labyrinth rings in
order to prevent against ingress of coal dust into the motor interior..

LOW VOLTAGE THREE-PHASE TOTALLY ENCLOSED MOTORS, INCREASED POWER, TYPE 2.ZPDI

3
BRUSHES AND BRUSHHOLDERS: The brushes are made of metal-graphite; the holders are of
cast brass. The whole assembly is connected with two sheet supports and with insulated bolts. It
is very simple for use through the terminal box. There are six brushes for each motor and three
brush holders. With brush holders there are terminated three cables to the terminal plate of rotor.

TERMINAL BOX: Terminal box is on the top of the motor. The terminals of rotor and stator are
separated by diagonal compartment. The terminals of rotor (3 cables) and stator (6 to12 cables)
are lead to the terminal plate of rotor and stator, where they are connected with the suitable
terminal bolts. In the terminal box there can be located also elements of accessories (heaters,
thermal protection). One of the points is earthed and located in the terminal box (the second on
the housing). Cable head makes cable supply from the network and from the rotor starter, which
may be on the left hand side, right hand side or both sides. Standard position is from the right
hand side. For accessories there are terminated entries with Re turns according to JUS
M.B0.090. The following table shows the basic data of the terminal box:


Terminal screws
Stator Rotor
MOTOR TYPE
Material Material
Permissible
current (A)

Number
of inlets

Dimension
of inlets

Max.cable
diameter
(mm)

Positionof
terminal
box

6 x M16 3 x M12
2.ZPDI 315
E Zn39 E-CuF25
315 / 315 2 75 70
6 x M20 3 x M16
2.ZPDI 355
ECuF25 E-CuF25
630 / 400 2 70 70
12 x M16 3 x M16
2.ZPDI 400
E-CuF25 E-CuF25
800 / 400 2 80 80
ABOVE


SHAFT ENDS: The motors are produced normally with one cylindrical shaft end and with central
box of 60 (with thread acc. to JUS M.A5.212). On special request they can also be delivered with
two cylindrical and with conical ends. For belt transmission it is necessary to consult the producer.
BALANCING AND VIBRATION: the motors are balanced dynamically with half key on the drive
shaft end, in quality which is in accordance with the requirements of IEC60034-14. The limits of
vibration severity are shown in the following table:

Limits of vibration severity in mms-1 forframe size H in mm
Free suspension Grade
Speed range
min-1
255 < H 400
N ! 600 " 3600 3,50
! 600 " 1800 1,80
R
> 1800 " 3600 2,80
! 600 " 1800 1,12
S
> 1800 " 3600 1,80
Standard design is in the degree of vibration strength N, on request we produce motors with
vibration strength degree R and S.








LOW VOLTAGE THREE-PHASE TOTALLY ENCLOSED MOTORS, INCREASED POWER, TYPE 2.ZPDI

4
NOISE: Motors satisfy thee noise level in accordance with IEC 60034-9. Noise level shown in the
below table refers to the no-load motors at 400 V, method of cooling IC 411 and mechanical
protection IP55. Tolerance is +3dB(A). Review is in the table as follows:


Frame size
(shaft height)
Noise level dB
(A)
315 355 400
LpfA (1) 84 85 87
4-pole
LwA(2) 98 99 100
LpfA 75 85 87
6-pole
LwA 89 99 99
LpfA 80 82 84
8-pole
LwA 94 96 98


(1)
LpfA - sound pressure
(2)
LwA - sound power








OVERLOAD CAPACITY: According to JUSIEC 60034-1 motors can be overloaded meaning that
motors heated to an operating temperature can withstand current equal to 1.5 times the rated
current for not less than 2 min. The motors can be overloaded by the torque 1.6 times the rated
one for 15 seconds without stalling or abrupt in speed.

THERMAL PROTECTION: On a special request stator winding of the motor can be protected
thermally by using PTC thermistors according to IEC 60034-11. In each phase of stator winding
there will be built in one thermistor (PTC resistor) for switch-off temperature of 150 C. All three
thermistors are connected in series and two ends are lead out in the terminal box and to the
switching-off unit (delivered on special request). Besides, the motors can be equipped with
additional thermistors for alarm.

HEATERS: The motors can be equipped with heaters as a protection against condensed water.
They could be exposed to danger of water condensation due to sudden and large changes of
temperature during the motor stand still. During the motor operation the heaters must be switched
off. Data of these heaters are shown in the following table:

Frame size
H, mm
Supply voltage
V
Heaters power
W
315 130
355 280
400
115 or 230
280

FINISH PAINTING: Standard finish painting of the motors is performed by protective alkyd paint
RAL 7001. For special climate conditions according to IEC 60721-2-1 painting is performed by
epoxy paint.

PACKING: The motors are packed normally in wooden packing material with fixed rotor in order
to avoid damage of bearing assemblies during transportation.

QUESTIONNAIRE: Please, answer the questions from the attached questionnaire as fully as
possible, to enable offering of induction electric motors, and send it to the producer.



LOW VOLTAGE THREE-PHASE TOTALLY ENCLOSED MOTORS, INCREASED POWER, TYPE 2.ZPDI

5


Power n cos I
N

Mm
Rotor
Mass J
TYPE M
N

Voltage
Current IM B3

kW min-1 % A V10% A kg kgm
2


ns=1500 min -1
2.ZPDI 315 Mk-4 132 1488 94,3 0,90 236 3,4 336 238 1400 5,20
2.ZPDI 315 M-4 160 1489 94,9 0,89 288 3,4 410 235 1560 6,32
2.ZPDI 315 L-4 200 1489 95,1 0,90 355 3,7 490 243 1700 7,90
2.ZPDI 355 L-4 250 1489 95,1 0,92 434 3,1 490 305 2360 11,70
2.ZPDI 355 Ld-4 315 1489 95,3 0,91 546 3,6 630 297 2590 14,30
2.ZPDI 400 Lk-4 355 1490 95,9 0,91 618 3,6 728 290 2830 25,30
2.ZPDI 400 L-4 400 1491 96 0,91 696 4,0 850 278 2982 29,30
2.ZPDI 400 Ld-4 450 1491 96 0,91 744 3,4 948 281 3150 32,90
2.ZPDI 400 Ldd-4 500 1491 96 0,91 870 4,2 1020 288 3420 35,40

ns=1000 min -1
2.ZPDI 315 Mk-6 110 989 94,2 0,87 204 2,6 229 292 1430 6,50
2.ZPDI 315 M-6 132 989 95,4 0,88 238 2,6 271 295 1540 7,90
2.ZPDI 315 L-6 160 990 95,5 0,88 288 2,7 331 291 1660 9,50
2.ZPDI 355 L-6 200 990 95,6 0,90 353 2,5 418 287 2120 14,50
2.ZPDI 355 Ld-6 250 990 95,6 0,90 442 2,5 505 300 2570 17,70
2.ZPDI 400 Lk-6 315 991 96 0,90 554 2,5 536 352 2800 28,20
2.ZPDI 400 L-6 355 991 96 0,90 624 2,8 643 328 3000 33,70
2.ZPDI 400 Ld-6 400 991 96 0,89 711 2,5 706 340 3280 37,00
2.ZPDI 400 Ldd-6 450 991 96,1 0,90 790 2,8 804 332 3570 42,10

ns=750 min -1
2.ZPDI 315 Mk-8 90 740 94,3 0,83 175 2,7 246 222 1380 7,90
2.ZPDI 315 M-8 110 741 94,6 0,84 210 2,7 303 220 1575 9,90
2.ZPDI 315 L-8 132 741 94,7 0,83 255 2,8 360 222 1660 11,60
2.ZPDI 355 L-8 160 742 95,4 0,87 293 2,4 350 275 1900 15,60
2.ZPDI 355 Ld-8 200 742 95,5 0,86 370 2,5 438 275 2140 19,30
2.ZPDI 400 Lk-8 250 742 95,5 0,86 462 2,0 395 388 2600 31,00
2.ZPDI 400 L-8 315 742 95,6 0,86 582 2,0 494 388 2995 38,80
2.ZPDI 400 Ld-8 355 742 95,6 0,86 656 2,1 564 382 3300 44,60
2.ZPDI 400 Ldd-8 400 742 95,7 0,86 738 2,1 635 384 3650 48,70

ns=600 min -1
2.ZPDI 315 Mk-10 75
2.ZPDI 315 M-10 90
2.ZPDI 315 L-10 110
2.ZPDI 355 L-10 132
2.ZPDI 355 Ld-10 160
2.ZPDI 400 Lk-10 200
2.ZPDI 400 L-10 250
2.ZPDI 400 Ld-10 315
2.ZPDI 400 Ldd-10 355
On request !





Protection: IP 55 Voltage: 380 V, 50 Hz
LOW VOLTAGE THREE-PHASE TOTALLY ENCLOSED MOTORS, INCREASED POWER, TYPE 2.ZPDI
2001
6


Power n cos I
N

Mm
Rotor
Mass J
TYPE M
N
Voltage Current IM B3

kW min-1 % A V10% A kg kgm
2


ns=1500 min -1
2.ZPDI 315 Mk-4 132 1489 94,3 0,87 232 3,9 354 225 1400 5,20
2.ZPDI 315 M-4 160 1490 95 0,86 283 3,9 433 222 1560 6,32
2.ZPDI 315 L-4 200 1490 95,1 0,90 337 4,2 516 230 1700 7,90
2.ZPDI 355 L-4 250 1490 95,1 0,91 417 3,5 516 290 2360 11,70
2.ZPDI 355 Ld-4 315 1490 95,1 0,91 524 4,1 664 281 2590 14,30
2.ZPDI 400 Lk-4 355 1491 96 0,90 593 4,1 767 274 2830 25,30
2.ZPDI 400 L-4 400 1492 96 0,90 668 4,5 895 264 2982 29,30
2.ZPDI 400 Ld-4 450 1492 96 0,89 760 3,9 998 267 3150 32,90
2.ZPDI 400 Ldd-4 500 1492 96 0,90 835 4,8 1073 273 3420 35,40

ns=1000 min -1
2.ZPDI 315 Mk-6 110 990 94,2 0,85 198 2,9 241 277 1430 6,50
2.ZPDI 315 M-6 132 990 95,4 0,86 232 2,9 285 280 1540 7,90
2.ZPDI 315 L-6 160 991 95,5 0,86 280 3,0 348 275 1660 9,50
2.ZPDI 355 L-6 200 991 95,6 0,88 343 2,8 440 272 2120 14,50
2.ZPDI 355 Ld-6 250 991 95,7 0,89 424 2,6 531 283 2570 17,70
2.ZPDI 400 Lk-6 315 992 96 0,88 538 2,9 564 333 2800 28,20
2.ZPDI 400 L-6 355 992 96 0,88 606 3,2 677 311 3000 33,70
2.ZPDI 400 Ld-6 400 992 96 0,88 684 2,8 744 321 3280 37,00
2.ZPDI 400 Ldd-6 450 992 96,1 0,88 768 3,2 847 315 3570 42,10

ns=750 min -1
2.ZPDI 315 Mk-8 90 741 94,3 0,79 174 3,0 260 210 1380 7,90
2.ZPDI 315 M-8 110 742 94,5 0,81 207 3,0 320 207 1575 9,90
2.ZPDI 315 L-8 132 742 94,6 0,80 252 3,1 378 210 1660 11,60
2.ZPDI 355 L-8 160 742 95,5 0,85 284 2,7 368 260 1900 15,60
2.ZPDI 355 Ld-8 200 743 95,5 0,83 364 2,8 462 260 2140 19,30
2.ZPDI 400 Lk-8 250 743 95,5 0,85 444 2,2 415 366 2600 31,00
2.ZPDI 400 L-8 315 743 95,6 0,85 560 2,2 520 366 2995 38,80
2.ZPDI 400 Ld-8 355 743 95,6 0,85 630 2,3 594 360 3300 44,60
2.ZPDI 400 Ldd-8 400 743 95,7 0,85 710 2,3 668 362 3650 48,70

ns=600 min -1
2.ZPDI 315 Mk-10 75
2.ZPDI 315 M-10 90
2.ZPDI 315 L-10 110
2.ZPDI 355 L-10 132
2.ZPDI 355 Ld-10 160
2.ZPDI 400 Lk-10 200
2.ZPDI 400 L-10 250
2.ZPDI 400 Ld-10 315
2.ZPDI 400 Ldd-10 355
On request !



Protection: IP 55 Voltage: 400 V, 50 Hz
LOW VOLTAGE THREE-PHASE TOTALLY ENCLOSED MOTORS, INCREASED POWER, TYPE 2.ZPDI

7


TYPE A AA AB AC AG B BA BA BB BD C H HA HB HD K L LC O BE BC
Mk 1661 1816
2.ZPDI 315 M 508 120 630 655 317
457
120 250 700 171 216 315 35 520 823 28 1751 1906 64 128 488
L 508 1851 2006
L 1867 2052
2.ZPDI 355
Ld
630 150 780 735 310 800 220 220 980 134 224 355 35 742 890 35
1997 2182
64 128 488
Lk 1150 1986 2156
L 1250 2086 2236
2.ZPDI 400
Ld
710 150 860 852 360 250 450
1350
134 224 400 40 760 1027 35
2186 2306
75 150 590
Ldd
900
1350 2286 2366




TYPE AC AG AD AG' L LA LC M N P S T O BE LF Z
Mk 1661 1816
2.ZPDI 315 M 630 317 508 205 1751 25 1906 600 550 660 24 6 64 128 874 8
L 1851 2006
L 1867 2052
2.ZPDI 355
Ld
728 310 535 387
1997
25
2182
740 680 800 24 6 64 128 894 8
Lk 1971 2156
L 2051 2236
2.ZPDI 400
Ld
855 360 627
2121 2306
940 880 1000 24 6 75 150 990 8
Ldd
360
2181
28
2366



IM B3 (IM 1001)
IM V1 (IM 3011)
LOW VOLTAGE THREE-PHASE TOTALLY ENCLOSED MOTORS, INCREASED POWER, TYPE 2.ZPDI

8


TYPE D DB E GA F V FB GB XE DA DC EA GC FA VA FD GD XEA
2.ZPDI 315 90 M24 170 95 25 130 22 91,7 M64x4 70 M20 140 74,5 20 105 18 71,4 M48x3
2.ZPDI 355 110 M24 210 116 28 165 25 110,9 M80x4 80 M20 170 85 22 130 22 91,7 M64x4
2.ZPDI 400 110 M24 210 116 28 165 25 110,9 M80x4 90 M24 170 95 25 130 22 91,7 M64x4





LOWVOLTAGE - THREE PHASE TOTALLY ENCLOSED
MOTORS, INCREASED POWER, TYPE 2.ZPDI
Customer:
____________________________________________________________________________
ITEM: _______________________________
Qty: _______________________________
A MOTOR DATA D POWER TRANSMISSION AND STARTING CONDITIONS
1 Motor type: Three phase: Single phase: 1 Coupling type:
2 Rotor type: Squirrel cage: Slip-ring: 2 Starting:
3 Rated output: P = _____________ kW
N 3 Number of consecutive startings:
4 Rated voltage: U = _____________ V Connect: Star
N
Delta Hot state: Cold state:
5 Rated frequency: f = _________________ Hz ___________ per hour ___________ per hour
N
6 Rated speed: n = _________________ rpm ___________ per day ___________ per day
N
7 Insulation class: F B
8 Duty type: S1 S2 S3 S4 S5 S6 S7 S8 S9 S10
ED % E ADDITIONAL REQUESTS FOR MOTOR EXECUTION
starts /h ________________ min __________ J __________ kgm 1 mot
2
Overloading from: _________________ % P
9
N
Standard: ________________ IEC or ________________ Duration: _________________ min
10 Cooling method: ________________ IC 2 Temperature rise: F B
11 Mounting arrengement: IM 3 Request for: vibration level __________ mm/s
12 Protection degree: Motor IP: ______________ Terminal box IP: ______________ noise level _____________ db
13 *Sense of rotation: Left Right Both 4 *Terminal box position:
14 Motor brake: yes no left right On top
Braking moment: ________________ Nm 5 Additional shaft loading sense
Brake voltage: ________________ V/Hz ________________ V,DC axial force radial force
15 No-load regime? (single phase motor) yes no 6 Converter feed operation: yes no
16 Rotor data: U = ____________ V I = ____________ A Converter type: __________________________
2c 2n
Manufacturer: __________________________
B DATA ABOUT THE DRIVEN MACHINE Speed range: from _____ to ___________ rpm
1 Type: 7 Sensor category (mark in lower field):
2 Required power: Taho gen. Encoder Absolute Resolver
3 Required speed: ________ ________ ________
4 Load torque characteristic: Sensor Type: ________________________________
Constant: Squared _________________ or _________________ 8 Flange size: _____________________________ mm
Speed %: 0 25 50 75 100 9 Second shaft end: yes no
Torque Nm: DA= ___________ mm EA= ___________ mm
5 Moment of inertia: J= _________________ kgm 10
2
Other requests and limits:
6 Running machine special data:
F
ADDITIONAL EQUIPMENT, SPARE PARTS AND
DOCUMENTATION
C AMBIENT CONDITIONS
1 Ambient temperature: C 1 Thermal protection: yes no
2 Relative humidity: % Type: ______________________________________________
3 Altitude (above sea level): m
4 Specific ambient conditions: 2 Bearings thermometers yes no
3 Anti-condesation heaters yes no
4 Spare parts yes no
5 Guarantee sheet yes no
6 Language of instruction list:
7 Other requests for packing:
H CUSTOMER
1 Company:
You are kindly requested to provide us with as much data as possible thus enabling us to offer
satisfactorily
2 Adress:
3 City:
4 Country:
5 Person:
6 Telefon / Telefax:
7 DK.00.03.11.002.1 e-mail:
Enquiry Number:
* OBSERVED FROM DRIVE END
HEAD OFFICE AUSTRIA
ATB Austria Antriebstechnik AG
Renngasse 6-8
1010 Wien, Austria
T: +43 1 90 250 - 0
F: +43 1 90 250 110
info atb-motors.com
www.atb-motors.com
@
AUSTRIA
ATB Motorenwerke GmbH
ATB Technologies GmbH
ASIA
ATB Motorentechnik GmbH
BAHREIN
ATB Austria Antriebstechnik
Aktiengesellschaft, Rep. Office Bahrain
BENELUX
ATB BeNeLux B.V.
GERMANY
ATB Antriebstechnik GmbH
ATB Motorentechnik GmbH
Schorch Elektrische Maschinen
und Antriebe GmbH
G.-Bauknecht-Str. 1
8724 Spielberg
T: +43 3577 757-323
F: +43 3577 757-182
info atb-motors.com
Millenium Park 11
6890 Lustenau
T: +43 5577 9010-0
F: +43 5577 9010-110
info atb-motors.com
141 Market Street,
# 07-01 International Factors
Building
Singapore 048944
T: +65 63721174
F: +65 62253524
dennis.tan atbs.com.sg
AlmoayyedTower
21st Floor c/o Regus
Seef District, Manama
Kingdom of Bahrain
T: +973 175 68 160
F: +973 175 67 901
Tasveld 14
8271 RW IJsselmuiden
T: +31 38 443 2110
F: +31 38 443 2111
verkoop nl.atb-motors.com
Silcherstrae 74
73642 Welzheim
T: +49 7182 14-535
F: +49 7182 14 590
info de.atb-motors.com
Helgolnder Damm 75
26954 Nordenham
T: +49 4731 365-0
F: +49 4731 365-159
info de.atb-motors.com
Breite Strae 131
41238 Mnchengladbach
T: +49 2166 925-0
T: +49 2166 925-100
mail schorch.de
@
@
@
@
@
@
@
POLAND
Fabryka Silnikow Elektrycznych Tamel S.A.
RUSSIA
ATB Rus OOO
SERBIA
ATB SEVER DOO SUBOTICA
ATB FOD d.o.o.
SWITZERLAND
ATB Schweiz AG
UK & IRELAND
ATB Laurence Scott Ltd.
ATB Morley Limited
Brook Crompton UK
CANADA
Brook Crompton
ul. Elektryczna 6
33 100 Tarnow
T: +48 14 632 11 00
F: +48 14 632 11 02
officetamel tamel.pl
Petrovka ul. 27
107031 Moscow
T: +7 495 95 66 326
vyacheslav.mikheyev a-tecindustries.com
Magnetna polja 6
24000 Subotica
T: +381 24 665 100
F: +381 24 546 893
sever rs.atb-motors.com
Dorda Vajferta 16
19210 Bor
T: +381 30 423 147
fod fod.co.rs
Industriestrae 28
5600 Lenzburg
T: +41 62 885 70-10
info ch.atb-motors.com
PO Box 25 Hardy Road, Norwich NR1 1JD
Norfolk
T: +44 1603 628 333
hvm.sales laurence-scott.com
Bradford Road
Leeds LS28 6QA
West Yorkshire
T: +44 113 257 1734
sales uk.atb-motors.com
St. Thomas Road, Huddersfield HD1 3LJ
West Yorkshire
T: +44 1484557200
F: +44 1484557201
csc brookcrompton.com
North America
264 Attwell Drive
M9W 5B2 Toronto, Ontario
T: +1 416 675-3844
ramzi.mallouk brookcromptonna.com
@
@
@
@
@
@
@
@
@
Company locations
ATB SEVER DOO SUBOTICA
Magnetna polja 6
24 000 Subotica
Serbia
Tel. +381 24 665-124
Fax +381 24 665-125
www.atb-motors.com
sever . @rs atb-motors.com

You might also like