Column 1
Column 1
=1.15
Mu=265.32KNm
Pu/fckbD = 1392*103/20*600*600
=0.193
Mu/fckbD2 = 265.32*106/20*600*600*600
=0.0614
Non dimensional Parameters:
Refer Chart:44 of sp16(fy=415 N/mm2) and (d/D=0.10) and read out he value of:
p/fck =0.04
p=20*0.04 =0.8
Asc =(pbD/100) =0.8*600*600/100
=2880mm2
Provide 4 bars of 25mm diameter main bar and 4 bars of 20mm diameter as
distributor(Ast =3218 mm2)
P =(100*3218)/(600*600)
P=0.893
(p/fck) =0.893/20
=0.045
Refer chart -44 in SP16 and read out (Mux1/fckBd2) corresponding to the value of
(Pu/fkBd)= 0.193 and (p/fck)=0.045
(Mux1/fckBd2) =0.065
Mux1 =0.065*20*600*600*600
=280.80KNm
Due to symmetry,Mux1 =Muy1 =280.80KNm
Puz =[0.45fkAc + 0.75fyAS]
=(0.45*20)[(600*600)-3218]+[0.75*415*3218]
=4212.6KNm
Pu/Puz=1392/4212.6
=0.335
Hence,
n=1.3
Check for Safety under biaxial bending
[(Mux/Mux1) n +(Muy/Muy1) n]
=[(174.48/280.80)1.3 +(150.95/280.80)1.3]
=0.984<1
Hence the section is safe under biaxial bending.
Tie Reinforcement
Diameter greater
1. 12/4 = 3
2. 6 mm
Adopt 8 mm dia. Bars
Pitch of ties is least of
1. Least lateral dimension= 600 mm
2. 16 x diameter of bars = 192 mm
3. 48 times dia. of bars
= 384 mm