EL SERIES
Consistent reliability with accuracy. Fixed or variable current sensitivity by Dip Switch selection LED's for visual indication of fault. High Barrier connector at rear for easy termination and safety standards. Tamper proof polycarbonate cover in the front. Test & Reset Facility for testing healthyness of the relay
Applications
F F F F
Frame Leakage protection for L.T. Control panels and switch boards. Earth leakage protection for feeders/motors/generators/transformers/mobile operating equipments. Protection for hazardous sensitive environments like oil refineries/chemical platforms/pulp industries and general electrical distribution. Protection for mining & control engineering
Specifications
F
: 110V, 230V, 415V, 550 VAC 50Hz 48V, 110V & 220V VDC
Variable : 30-300mA, 50-2000mA,300-3000mA,30-3000mA 1-4A, 1-8 Amps, 1-10A, 4-12A. Fixed : 30mA, 100mA, 300mA, 500mA also user specified ranges (sensitivity)
F
Tripping time Variable : 0.15 - 3 Sec Fixed : 100 millisec, 500 millisec, 1 Sec & 3 sec. Core balance current transformer type : Tape wound or Resin cast CBCT-Standard size I.D. Round : 40mm, 65mm, 100mm, 150mm, 200m, 250mm & 300mm Rectangular : User specified : One pair of potential free NO & NC contacts or Two change over potential free NO&NC Contacts : 6 Amps / 230VAC / 28 VDC : Flush / Din
F F
F F F F
Flush : 96mm 96mm 70mm Panel Cutout size : 90 90 + 0.1mm Din : 75 95 75 mm (L H D) (fixing on 35mm din channel) Note : 30-300 mA,50-2000mA & 30 - 3000mA ELR is available upto 150 mm I.D. CBCT Only.
Introduction
Earth Leakage Current give rise to generation of heat and result in progressive failure of insulation, which leads to earth faults sparking flashovers, deterioration of earthing and finally results into catastrophic fires which destroys costly equipments, gadgets and precious lives. It is therefore essential to detect earth leakage current well before they cross the threshold limits and isolate the circuit in the event of leakages. Conventional over current and short circuit protection device are not designed to detect earth leakage currents Make Earth Leakage Relays (ELR) with Core Balance Current Transformer (CBCT) are used to detect the leakage current in an Electrical Power System. ELR transmits a signal to activate the trip coil of the MCCB / ACB / OCB / CONTACTOR in the event of earth leakage, resulting in automatic isolation of the electrical power system. ELR have been widely used and accepted because these have field adaptability and are economic.
TM
Principle of Operation
ELR employs a Core Balance Current Transformer (CBCT) to sense the leakage current. The CBCT is mounted externally and load current carrying cable are passed through the CBCT. Ideally in a leakage free system the incoming and outgoing currents are equal and opposite in direction, which means that the vector sum of three phase currents is zero and can be expressed as : IR + IY + IB = 0 for 3 phase 3 wire system. IR + IY + IB + IN = 0 for 3 phase, 4 wire system. For the above condition the CBCT produces zero resultant magnetic flux keeping the system healthy.
http:www.prokdvs.com e-mail:[email protected]
TM
In case of Earth leakage either due to insulation failure of direct line to ground fault, the vector sum of currents is not zero and therefore generates resultant magnetic flux in the CBCT, and the signal is fed to the electronic circuit of ELR. This signal is compared with internal reference determined by the selected position of the leakage current scale in the front facia of the relay, this engergizes the output when the signal crosses the preset level. The potential free contacts of the relay is connected to the Shunt Trip / NO volt coil of the main trip device like MCCB / OCB / ACB / CONTACTOR etc., Under fault condition the output relay gets activated by cutting off or tripping against Earth Leakage / Faults. It is worthwhile to emphasize that the unequal / unbalanced loading on the phases does not effect the vector sum and as such there is no difficulty in the use of ELR on electrical distribution systems with unbalanced loading.
EARTH LEAKAGE RELAY FOR MINING, CEMENT, PETROLEUM & OIL REFINERIES, STEEL, SHIPPING, PAPER & PULPING INDUSTRIES M-series ELR : make M-series ELR has the following features which are useful in underground mining application. External
TM
termination for healthy indication & fault indication, this feature is help ful in observing the indications at a distance. CBCT test facility is useful in checking the healthyness of the relay including the CBCT. CBCT test is achieved by means of operating the CBCT test-key in front fascia. External test & reset are also brought out so that the relay can be tested externally. Tapping for different auxiliary voltage this feature helps in using the ELR at different supply voltages.
Specification
Aux. Voltage Leakage range Time selection Contacts CBCT Mounting : 0-440V - 550V AC tapings. : 0.03A - 3.0A : 0.15sec - 3sec : Two change over 2NC & 2NO, 6Amps rating, 230V AC, 28VDC : Test Facility : din rail
EARTH LEAKAGE RELAY FOR NON-LINEAR LOADS LIKE UPS, INVERTOR, DRIVES & OTHER APPLICATIONS H-series ELR :
TM
manufactures the most trusted/dependable earth leakage relays for more than 15 years and they are time tested
H series earth leakage are different from other normal leakage relays. The term H denotes harmonics, Prok dvs make H series is suitable for electrically noisy environment. Power distribution systems are becoming non-linear this necessitates the earth leakage detection system to be more effective in handling harmonics & to prevent spurious/nuisance tripping of earth leakage relay due to high frequency harmonics [predominantly 3rd & 4th harmonics ). H series relay achieves the above harmonic discrimination by using a built in attenuation mechanism which effectively prevents harmonics to influence the characteristics quantity (leakage current), hence preventing the nuisance tripping of ELR. The design of H-series CBCT has been modified, CBCT dimensions are different from regular ELR & CBCT.
Wiring diagrams
WIRING DIAGRAM FOR FLUSH MOUNTING E.L.R 3, 415V AC INCOMING
CBCT
CBCT
OUT GOING
RATED VOLTAGE FOR SHUNT TRIP COIL/UVR/OVR (FROM LOAD SIDE) REAR VIEW OF E L R
OUT GOING
NOTE: FOR SHUNT RELEASE CONNECT C & N/O CONTACTS FOR UV RELEASE OR CONTACTOR COIL CONNECT C & N/C CONTACTS ARE SHOWING IN HEALTHY CONDITION
NOTE: FOR SHUNT RELEASE CONNECT C & N/O CONTACTS FOR UV RELEASE OR CONTACTOR COIL CONNECT C & N/C CONTACTS ARE SHOWING IN HEALTHY CONDITION
http:www.prokdvs.com e-mail:[email protected]
TM
SIDE VIEW
RH I n = 300 mA t = 250 ms
FRONT VIEW
RH I n = 100 mA t = 90 ms
TOP VIEW
RH I n = 30 mA t = 0 Sec
Mechanical Dimensions
MECHANICAL DIMENSION OF FLUSH MOUNTING E.L.R MECHANICAL DIMENSION OF DIN MOUNTING E.L.R
TOP VIEW
TOP VIEW
http:www.prokdvs.com e-mail:[email protected]