SEENOPEX INSPECTION SERVICES

Inspection Report for Drill Collar According To DS-1


Customer: Well Name & Location: Connection & OD Size: IDC IDC WORK SHOP NC50 & 6 3/4" Date Of Service : Seenopex Work Order Dimensional (3) 16/08/203 IDC-167 III Min bevel width Min counter bore depth Category
1

SPX-IMS-F-063
/32

18/32 3-5

Condition Serial No.

Pin

Box
Pin Tong

Body
Overall (ft) Box Tong

BB cly

Bevel

C 1010 C 751 C 1641 C 1272

ACC ACC ACC ACC

ACC ACC ACC ACC

ACC ACC ACC ACC

6 5/8" 6 5/8" 6 5/8" 6 3/4"

3" 3" 3" 3"

4 23/32" 4 23/32" 4 23/32" 4 23/32"

1" 1" 1" 1"

6 3/8" 6 3/8" 6 3/8" 6 3/8"

6 5/8" 6 5/8" 6 5/8" 6 3/4"

5 10/32" 5 10/32" 5 10/32" 5 10/32"

4 5/8" 4 5/8" 4 5/8" 4 5/8"

8" 8" 8" 8"

6 3/8" 6 3/8" 6 3/8" 6 3/8"

Bevel

SRG

SRG

Body

CB

BB

Box

OD

OD

Pin

ID

20 3/4" 18" 15" 19"

28 1/8" 20 3/8" 32 1/4" 31 1/2"

29' 1" 28' 2" 28' 10" 29' 2"

Result: Remarks
OD EGR GT G (good)

04 Joints Were Found Acceptable (Ready To Use).

Abbreviations:
Outside Diameter Diameter Elevator Groove Recess Galled Thread 100-90 % Coating Colors Code: ID SGR TP F (fair) Red Inside Diameter Length Slip Groove Recess Thread Pitting 75-90 % Coating Short T. Joint SRG CR SP P (poor) Yellow Stress Relief Groove Width Crack Seal Pitting Less than 75 % Coating 2 Class
nd

CB B TD E Orange

Counter Bore Depth Bent Thread Damage Nil 3 Class


rd

BB NP. PC SD

Bore Back Not Present Premium Class Seal Damage

FB NA. RF M WT

Float Bore Not Applicable Reface Mashed Wall Thickness Need Hard Banding

Blue

Re-cut Conn.

Green

Inspector:

OSAMA ALI

Supervisor:

Mostafa Hassan