Power TF
Power TF
Power TF
W E
T R A N S F O R M
T H E
N A T I O N ' S
P O W E R
INTRODUCTION
Technical Associates Ltd. (TAL) is one of the Top Ten manufacturers of Power Transformers in India. Manufacturing Capacity: 11,000 MVA p.a. Range: Single phase / Three phase transformers up to 200 MVA, 220 KV: o o o o Generator Transformers Station Transformers Auto Transformers System Transformers
Additional infrastructure available to manufacture 765 KV Class transformers. More than 400 Power Transformers already delivered & successfully commissioned for various customers in India. All delivered transformers successfully type tested from accredited 3rd party test houses (as per IEC 60076 and IS 2026). In-house design team of highly experienced engineers uses CAD techniques for development and continuous improvement of reliable, cost-effective transformers in conformance with IS, IEC or ANSI standards. Designs for Power Transformer take care of Electro-magnetic, Electro-mechanical & Thermal aspects based on individual customer needs. Software based design techniques ensure structural strength, short circuit withstand capacity, lighting impulse withstand capacity, short duration overload, noise disturbances and vibration. Special software is used for optimization of material cost and labour. Sophisticated and calibrated testing equipments for in-house Routine and Type Tests. Strict Quality control for incoming stock, process monitoring and finished products using SQC techniques. Installation, commissioning and repairing of Power and Distribution Transformers by trained and experienced engineers backed by timely supply of spares.
Core-Coil Assembly
Core Building
TESTING
Documented in-process checks ensure low lead times and process reliability. Fully computerized automatic testing facilities for all routine tests as per IS, IEC, ANSI. Tests on each Power Transformer include: o o o o o Turns ratio check Polarity check No load current and loss measurement Percentage impedance and load loss measurement Induced over voltage test, separate source voltage withstand test o o o Insulation resistance measurement Winding resistance measurement Pressure test for detection of oil leakage
Computerized Test Bench
Impulse testing facilities from Haefely (Switzerland) (1600 KVp, 160 KJ & 99 KVp, 45 KJ) installed upgradeable for testing of 400 KV transformers. In-house Temperature rise test plant. PD measurement facility. DGA for Oil analysis. Short-circuit test at Independent accredited Laboratories as per customers' requirement.
Impulse Testing Lab
QUALITY
TAL Quality Policy We, at Technical Associates Ltd., are committed to achieve total satisfaction of our customers by: Effectively implementing and continually improving the Quality System. Delivering on time, products conforming to agreed specifications at competitive prices. Collectively and individually striving to do things right-the first time and every time-both in personal life as well as at the workplace. Continuous up-gradation of technology and active involvement of all employees and associates in productivity improvement.
SERVICES
TAL also undertakes installation and commissioning of Power Transformers of its own make on customer request for the same. TAL service team consists of experienced Engineers having expertise of installation, commissioning and repairing. We also offer comprehensive maintenance of all TAL installations. Our service is backed by supply of spares and components in shortest time as per customer needs. TAL also undertakes specialized service activities which include: Repair of Power Transformers up to 400 KV and Turnkey Execution of Power Projects.
Height 2800 3500 Height 4200 4500 4800 4800 Height 4300 5200 3400 5000 5600 6000
Dimension (mm) Length Breadth 5460 4150 5600 4200 5600 3900 5900 4200 Dimension (mm) Length Breadth 5460 4150 6300 3900 5800 2500 6300 5000 6600 5620 7500 5100
Dimension (mm) Length Breadth Height 10000 4800 7840 12500 7600 9200
Note : The above figures are indicative only. Customised transformers in Intermediate sizes can be built as per specification with ON LOAD / OFF LOAD tap changer.
10000
1U
2300 (MIN.)
I.V. BUSHINGS 145 KV,800A.
1V
2300 (MIN.)
H.V. BUSHINGS 245 KV,800A.
1W
AIR CELL
R19 60
2U
1350 (MIN.)
2V
1350 (MIN.)
2W
R19 60
R350
NEUTRAL BUSHING 36 kV, 1000A.
R350
R350
2500
M. BOX
1000
*
G.L. G.L.
PROPS 4NOS.
BSI
QUALITY MANAGEMENT
014
FM 561794
An ISO 9001:2008 Company
Lucknow Plant (Corporate Office) 8th Km., Faizabad Road, Ismailganj, Lucknow 226 016 Phone: +91 (522) 4053600 Fax : +91 (522) 4053601
Sitarganj Plant B-7, Eldeco Sidcul Industrial Park, Sitarganj, U.S.Nagar, Uttarakhand - 262405 Phone: +91 (594) 8256032 Fax : +91 (594) 8256031