100% found this document useful (1 vote)
1K views5 pages

Insulation Resistance Test

The document describes an insulation resistance test which measures the resistance between conductors and earth and between conductors using a megger insulation tester. The purpose is to prove the quality of insulating materials and ensure no possibility of earth leakage currents. A direct current voltage of at least twice the normal supply voltage is used, up to a maximum of 500V. The minimum accepted insulation resistance value is 1 megohm. Insulation resistance can vary depending on moisture and dirt levels and may deteriorate over time due to aging or unsuitable operating conditions.

Uploaded by

Moses Torkudzor
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
1K views5 pages

Insulation Resistance Test

The document describes an insulation resistance test which measures the resistance between conductors and earth and between conductors using a megger insulation tester. The purpose is to prove the quality of insulating materials and ensure no possibility of earth leakage currents. A direct current voltage of at least twice the normal supply voltage is used, up to a maximum of 500V. The minimum accepted insulation resistance value is 1 megohm. Insulation resistance can vary depending on moisture and dirt levels and may deteriorate over time due to aging or unsuitable operating conditions.

Uploaded by

Moses Torkudzor
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 5

Insulation Resistance Test

Insulation Resistance Test


Cable under test

Megger Insulation tester

Insulation Resistance between conductors and earth Insulation resistance between conductors

Insulation Resistance Test


Sometimes it is helpful to ground all conductors that are not part of the test. Why? ( Assignment)

Insulation Resistance Test


Purpose of IR is to prove the quality of the insulating materials used in the installation Insulation should be such that there is no possibility of earth leakage currents between conductors conductors and the general mass of earth. The test voltage is d.c not less than twice the normal voltage of the supply (r.m.s value) For test on medium-voltage circuits the test voltage need not exceed 500V d.c. The minimum accepted value of IR is one Megohm.

Insulation Resistance Test


IR value of an installation will not always remain the same. A good deal depends on the amount of moisture and dirt present at the time of testing. Deterioration of the insulation is usually due to: aging unsuitable operation conditions

You might also like