0% found this document useful (0 votes)
29 views1 page

International Limited: Certificate of Visual Examination and Dpi

This document is a certificate of visual examination and dye penetrant inspection for a TMS Latch Mechanism. It was inspected on July 3, 2012 by Omoyibo Patrick and found to have no defects at the time and deemed fit for use. The inspection was conducted according to various UK standards for lifting equipment and machinery safety at the location of RIG 135, which is owned by Transocean Support Service.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
29 views1 page

International Limited: Certificate of Visual Examination and Dpi

This document is a certificate of visual examination and dye penetrant inspection for a TMS Latch Mechanism. It was inspected on July 3, 2012 by Omoyibo Patrick and found to have no defects at the time and deemed fit for use. The inspection was conducted according to various UK standards for lifting equipment and machinery safety at the location of RIG 135, which is owned by Transocean Support Service.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

JCInternationalLimited

RC.413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND DPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination 03/07/12


Qty

Examiner OMOYIBO PATRICK


TARE WT SWL GROSS WT

Qualifications LEEA, SNT LEVEL II MT, PT & UT


Proof Load Applied Date of next Examination

70330
Identification Number

Description of Equipment

TMS LATCH MECHANISM TH 587/4 1pc

TMS Latch Mechanism (ROV-0186-D-0907-00)

N/A

5 Tonnes

N/A

N/A

02-01-13

LOCATION: SUBSEA WORKSHOP


SPECIFICATION : BS 6971 DPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-030 Penetrant Developer

PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: Transocean Support Service

Address of premises where Test / Examination was held: RIG 135

We hereby certify that on 03/07/12 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OMOYIBO PATRICK Conducting: Examination only

Revision No: 01