History Background Document: IP 15-8-2 Sample Transport and Sample Conditioning Systems For Process Stream Analyzers
History Background Document: IP 15-8-2 Sample Transport and Sample Conditioning Systems For Process Stream Analyzers
IP 15-8-2
Page 1 of 1 Rev. 2 June 1999
5.1 5.2 5.3 5.4 5.5 5.6 5.7 8.1 8.11 9.10 10.1 10.2 11.1 11.2 11.3 11.4 11.7 11.8 11.10 11.12
Minimizes risk of hydrocarbon spill or release. Minimizes risk of hydrocarbon spill or release. Minimizes risk of hydrocarbon spill or release. Minimizes risk of ammonia release. Minimizes risk of hydrocarbon release due to possible mechanical damage to the sample tubing. Minimizes risk of process fluid release. Minimizes risk of process fluid release. In combination with analyzer shelter ventilation requirements, intended to keep any hydrocarbon or toxic releases inside enclosed analyzer shelters remain below LEL and TLV limits. Minimizes risk of hydrocarbon release. Minimizes risk of hydrocarbon release and provides personnel safety. Minimizes release of hydrocarbon and toxic materials to the ambient environment. Minimizes release of hydrocarbon and toxic materials to the ambient environment. Minimizes risk of process fluid release. Minimizes risk of process fluid release. Minimizes risk of process fluid release. Minimizes risk of process fluid release. Provides protection against personnel injury. Provides personnel protection from toxic vapors and minimizes release of hydrocarbon and toxic materials to the ambient environment. Minimizes risk of process fluid release due to possible mechanical damage to the sample tubing. Minimizes risk of process fluid release.
[H] [H] [H] [H] [H] [H] [H] [H] [H] [H]
12.1.a. Minimizes risk of process fluid release. 13.1 13.3 14.3 14.4 Needed in order to assess whether all electrical equipment is safe to operate in specified hazardous area environment. Intended to provide personnel safety. Minimizes risk of process fluid release. Minimizes risk of process fluid release.
Notes: (1) (2) Each paragraph to identify the Purpose Code(s) of the corresponding paragraph number of the applicable International Practice (IP). The symbol [ H] is used to denote all History Background Paragraphs which are for INFORMATION ONLY.
THIS INFORMATION FOR AUTHORIZED COMPANY USE ONLY EXXON RESEARCH AND ENGINEERING COMPANY FLORHAM PARK, N.J.