Grade Beam Details For Stub Columns
Grade Beam Details For Stub Columns
1.
EXTERIOR WALL
SPAN IN
metre
Up to 3.0 m
3.0 to 3.50m
I-STOREY
Size in mm Reinft
230 x 300
3-10 #
Size in
mm
230 x 300
230 x 300
3-10 #
230 x 400
230 x 300
3-12 #
3.6 to 4.20m
8
Stirrups
II-STOREY
Reinft
3-12 #
Size in
mm
230 x 400
3-12 #
230 x 400
III-STOREY
Reinft
3-12 #
3-16 #
230 x 400
230 x 450
2-16 #
3-16 #
+
1-12 #
mm # 2 Legged Stirrups @ 250mm C/c
2. INTERIOR WALL
SPAN IN
metre
Up to 3.0 m
I-STOREY
Size in mm Reinft
230 x 300
3-10 #
230 x 300
3-12 #
230 x 400
2-16 #
+
1-12 #
230 x 450
3-16 #
230 x 400
3-12 #
230 x 450
3-16 #
230 x 450
4-16 #
Stirrups
3-12 #
Size in
mm
230 x 400
III-STOREY
Reinft
Size in
mm
230 x 400
3.0 to 3.50m
3.6 to 4.20m
II-STOREY
Reinft
3-16 #