0% found this document useful (0 votes)
60 views2 pages

System Advisor Model Report

This System Advisor Model report summarizes the key metrics and costs for a proposed 99.9 MW nameplate parabolic trough solar thermal power plant located in Barmer, Rajasthan, India. The plant would have a solar multiple of 1.5, 839,015 square meters of aperture area, and 2 hours of thermal storage. It is estimated to generate 219 GWh annually, have a 25.1% capacity factor, and levelized costs of electricity of 22.59 cents/kWh nominal and 18.25 cents/kWh real. The total installed cost would be $587 million with a per capacity cost of $5,879/kW and an internal rate of return of 3.4

Uploaded by

Vineeth Sivaraj
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
60 views2 pages

System Advisor Model Report

This System Advisor Model report summarizes the key metrics and costs for a proposed 99.9 MW nameplate parabolic trough solar thermal power plant located in Barmer, Rajasthan, India. The plant would have a solar multiple of 1.5, 839,015 square meters of aperture area, and 2 hours of thermal storage. It is estimated to generate 219 GWh annually, have a 25.1% capacity factor, and levelized costs of electricity of 22.59 cents/kWh nominal and 18.25 cents/kWh real. The total installed cost would be $587 million with a per capacity cost of $5,879/kW and an internal rate of return of 3.4

Uploaded by

Vineeth Sivaraj
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

System Advisor Model Report

Physical Trough System Commercial PPA 99.9 MW Nameplate $5,879/kW Installed Cost Barmer, Rajasthan 25.75 N, 71.38 E GMT +5.5

Resource Annual Beam Irradiance: 1971 kWh/m2 System Specifications Solar Multiple: 1.5 Aperture Area: 839015 m2 Total Land Area: 870 acres Gross Capacity: 111 MW ( 100 MW net) Hours of Thermal Storage: 2 Cooling Method: Wet Key Metrics Annual Generation: 219 GWh Capacity factor: 25.1 % LCOE (nominal): 22.59 cents/kWh LCOE (real): 18.25 cents/kWh Internal Rate of Return: 3.4 % Cost Information Total installed: $ 587 million Per capacity: 5879 $/kW

System Advisor Model Standard Report

SAM 2013.1.15 Mon Apr 22 03:27:45 2013

Page 1 of 2

System Advisor Model Standard Report

SAM 2013.1.15 Mon Apr 22 03:27:45 2013

Page 2 of 2

You might also like