DIAGNOSTIC CHART FOR CENTRIFUGAL PUMP TROUBLES

(source of document unknown)

PROBLEM
Pump does not deliver water Insufficient capacity delivered Insufficient pressure delivered Pump looses prime after starting Pump requires excessive power Stuffing box leaks excessively Packing has short life Pump vibrates or is noisy Bearings have short life Pump overheats and seizes

POSSIBLE CAUSES
12346111416172223 23456789101316192122282930 51315161921282930 235678101112 1415161718192223252628323336 1223253132333435373839 1112232527313233343536373839 2349102022232425262729343540 414243444546 23252627343540414243444546 142021232627343540

LIST OF POSSIBLE CAUSES


Suction troubles 1. Pump not primed 2. Pump or suction pipe not completely filled with liquid 3. Suction pipe lift too high 4. Insufficient margin between suction pressure and vapor pressure 5. Excessive amount of air or gas in liquid 6. Air pocket in suction line 7. Air leaks in suction line 8. Air leaks into pump through stuffing box 9. Foot valve too small or partially clogged 10. Inlet of suction pipe insufficiently submerged 11. Water seal pipe plugged 12. Seal cage improperly located in stuffing box, preventing sealing fluid entering space to form seal System troubles 13. Speed too low 14. Speed too high 15. Wrong direction of rotation 16. Total head of system higher than design head of pump 17. Total head of system lower than design head of pump 18. Specific gravity of liquid different from design 19. Viscosity of liquid different from design criteria 20. Operation at very low capacity 21. Parallel operation of pumps unsuitable for such operation Mechanical troubles 22. Foreign matter in impeller 23. Misalignment 24. Foundations not rigid 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. Shaft bent Rotating part rubbing on stationary part Bearings worn Wearing rings worn Impeller damaged Casing gasket defective permitting internal leakage Shaft or shaft sleeves worn or scored at the packing Packing improperly installed Incorrect type of packing for operating conditions Shaft running off center because of worn bearings or misalignment Rotor out of balance resulting in vibration Gland too tight resulting in no flow of liquid to lubricate packing Failure to provide cooling liquid to water cooled stuffing box Excessive clearance at bottom of stuffing box between the shaft and casing, causing packing to be forced into pump interior Dirt or grit in sealing liquid, leading to scoring of shaft or shaft sleeves Excessive thrust caused by a mechanical failure inside the pump or by the failure of the hydraulic balancing device, if any Excessive grease or oil in bearing housing or lack of cooling, causing excessive bearing temperature Lack of lubrication Improper installation of antifriction bearings (damage during assembly, incorrect assembly of stacked bearings, use of unmatched bearings as a pair, etc.) Dirt getting into bearings Rusting of bearings due to water getting into housing Excessive cooling of water cooled bearing resulting in condensation in the bearing housing from moisture in the atmosphere

41. 42. 43. 44. 45. 46.

5764 Monkland avenue, Suite 311, Montreal, Quebec, Canada H4A 1E9 Tel: 514.484.PUMP (7867) Fax: 514.484.2294 E-mail: [email protected] Web site: www.fluidedesign.com