Saudi Aramco 2741-M-ENG (08/2001)

ENGG CERT PMT OPRNS


YSY

SAUDI ARABIAN OIL COMPANY


CENTRIFUGAL PUMP DATA SHEET FOR HORIZONTAL PUMPS AND VERTICAL IN-LINE PUMPS
BY MANUFACTURER OF PUMPS OR PUMPS PER 31-SAMSS-004
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN N FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.

MMQ

DCO

NOTE: O INDICATES INFORMATION TO BE COMPLETED BY PURCHASER; PURCHASERS REFERENCES


APPLICABLE TO: PUMP MFR SIZE & TYPE SERIAL NO. DRIVER TYPE PROPOSALS PURCHASE AS BUILT

BY MANUFACTURER OF PUMPS PER ASME B 73.1 OR B 73.2

SITE CONDITIONS
INDOOR ON SHORE ELECTRICAL AREA CLASS OUTDOOR COASTAL 1 , DIV. UNDER ROOF OFF SHORE , GROUP 2 IIA

YDH

FLOWSERVE 3K6X416RVM3ST
ELECTRIC MOTOR X12 SEVENTEEN (17) PUMP(S) -G- 0001 to 0017 , , -G-

PERFORMANCE DATA PERFORMANCE


-G-G-G-GRATED SPEED DRIVER NAME PLATE POWER RATING MIN. CONT. STABLE FLOW 59.5 60.77 32.1 2.5 RPM kW

THIS DATA SHEET COVER PUMP MARK NO(S).

1775 55
RPM 100% 120%

DESCRIPTION

PUMPS OF IDENTICAL TYPE & SIZE IN OPERATION -G, -G, DRIVER DATA SHEET GEAR UNIT DATA SHEET N/A
ISSUED FOR CONSTRUCTION

PERFORMANCE AT m TOTAL DIFF. HEAD % EFFICIENCY REQUIRED POWER kW NPSH REQ'D FOR: 3% 1st STAGE ON H2O m 40,000 HRS LIQ'D PUMPED m

NORMAL FLOW 52 74.1 43.8


4.1

OF RATED CAPACITY 45.5 52 74.1 47.8 4.1 71.8 47.5 5.3

LUBE OIL SYST DATA SHEET SAFETY INSTRUCTION SHEET LCC EF N/A $/kW

N/A

SERVICE
PUMP FUNCTION CONTINUOUS ATTENDED INDIVIDUALLY DIESEL LOADING PUMP INTERMITTENT UNATTENDED IN SERIES N/A N/A DOWNSTREAM OF PUMP NO(S) N/A N/A IN PARALLEL -G-G-G-GSTANDY BY

UPSTREAM OF PUMP NO(S)

REV. NO.

LIQUID CHARACTERISTICS
LIQUID PUMPED DIESEL TDS
OC OC

N/A 35 47 0.84 5.51 cp

mg/L

DISCIPLINE ENGINEER CMM DATE: DEC 2010

NORMAL FLOW TEMPERATURE MAX. FLOW TEMPERATURE RELATIVE DENSITY AT NORMAL FLOW TEMP. VISCOSITY AT FLOW TEMP. VAPOR PRESSURE AT NORMAL FLOW TEMP. V.P. AT MAX. FLOW TEMP. TSS NONE N/A PULPY VOL. %

SHUT-OFF HEAD AT ACTUAL IMP. DIAM. m AT MAX. IMP. DIAM. m L/s CAPACITY AT END OF CURVE TOT.DIFF. HEAD AT END OF CURVE m RATIO. SHUT-OFF HEAD/RATED HEAD RATIO. END OF CURVE CAPACITY/RATED L/s MINIMUM CONTINUOUS STABLE FLOW L/s MINIMUM CONTINUOUS THERMAL FLOW s MAXIMUM OPERATING TIME AT SHUT-OFF FIRST CRIT. SPEED; DRY RPM FIRST CRIT. SPEED; WET RPM MAX. ALLOWABLE SPEED RPM MAX. POWER FULL CURVE ACTUAL IMP.DIAM. kW POWER AT SHUT-OFF HEAD kW PERFORMANCE WITH MAX. AND MIN. IMPELLER DIAMETERS TOT.DIFF. HEAD AT RATED CAPACITY EFFICIENCY AT RATED CAPACITY REQUIRED POWER AT RATED CAP. MAX. REQUIRED POWER FULL CURVE / / INTERMEDIATE TRANSMISSION GEAR BOX HYDR. COUPL. SPEED RANGE MAX. 84.5 68 77.5 113

60.2 89.5 107 36.2 15.96 41.1 39.9

JO/EWO

10-007950002

12-18-10

DATE


6990

00

1800 50.2 19.6

PROJECT ENGINEER YDH DATE: DEC 2010

Mpa.s, mm2/s

MIN.
34.67

kPa(abs) kPa(abs) mg/L GRITTY N/A HARD

8 8 UNKNOWN SOFT UNKNOWN

m % kW kW

CERTIFIED
DCO DATE: DEC 2010

66.5 32 34.2

CHARACTER OF SOLIDS: GAS IN FLUID: NONE

RATIO % % OF DRIVER SPEED

CONSTRUCTION AGENCY SHK DATE: DEC 2010

PRINCIPAL CORROSIVES: N/A pH N/A CI mg/L

CONSTRUCTION DATA PUMP TYPE

OPERATIONS
YSY DATE: EDSD VERIFICATION DEC 2010 CONTROL NUMBER

OPERATING CONDITIONS
CAPACITY RATED TOTAL DIFFERENTIAL HEAD NPSH AVAILABLE AT SUCTION FLG. AT RATED CAPACITY AT 120% OF RATED CAPACITY
DATE:

NORMAL L/s RATED L/s m

75.8 75.8 52.0

HORIZONTAL (BET. BRGS) VERT. IN-LINE CASING MOUNT: CENTERLINE FOOT VERT. IN-LINE IN-LINE CASING SPLIT CASING TYPE SELF PRIMING AXIAL DOUBLE VOLUTE DIFFUSOR YES

OVERHUNG INTEGRAL SHAFT FLANGE CENTERLINE CASE SUPPORTED RADIAL SINGLE VOLUTE STAGGER NO CW

m m

9.93(SEE NOTE 2) 9.02(SEE NOTE 2) N/A

VISC. CORR. FACTOR CQ; CH; CE RATED SUCTION PRESSURE MAX. SUCT. PR. AT RATED CAP.

BY:

kPa(abs) kPa(abs) kPa(abs) kPa kPa(abs) kPa(abs)

89.47 255.94 256 429 518.47 684.94

DIR. OF ROT. CCW (VIEWED FROM DRIVER)

REVISION VISION CERTIFICATION

APPROVAL/CERTIFICATION ROVAL/CERTIFICATION REQUIREMENTS,

(DCC) C) NO. 10-00795-0002-045 ______________________________

00

OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE

MAX. SUCT. PR. AT SHUT-OFF TOTAL DIFFERENTIAL PRESSURE RATED DISCHARGE PRESSURE MAX. DISCH. PR. AT RATED CAP.
DATA SHEET FOR

PUMP NOZZLES
SUCTION DISCHARGE SIZE 6.00" 4.00" RATING 150# 150# FACING RF RF LOCATION END TOP

THIS S INDICATES THAT REV. NO.

X12-G-0001 To 0016 + WarehouseSpare 0017 (Total 17 Pumps)

DWG. TYPE

PLANT NO.

INDEX

DRAWING NO.

SHT.NO.

REV.NO.

DIESEL LOADING PUMPS WASEA BULK PLANT WASEA

DAT
SAUDI ARABIA

X12
JO / EWO:

VE-383773 E

10-00795-0002

1 OF 4

00

EDSD/2741-M-1-0801.XLS

Saudi Aramco 2741-M-ENG (07/2000)


ENGG CERT PMT OPRNS
YSY

SAUDI ARABIAN OIL COMPANY


CENTRIFUGAL PUMP DATA SHEET FOR HORIZONTAL PUMPS AND VERTICAL IN-LINE PUMPS
BY MANUFACTURER OF PUMPS OR PUMPS PER 31-SAMSS-004
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN N FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.

MMQ

DCO

NOTE: O INDICATES INFORMATION TO BE COMPLETED BY PURCHASER; CONSTRUCTION DATA (CONT'D) FORCES AND MOMENTS
ALLOWABLE FORCES AND MOMENTS
TOP NOZZLE Fx Fy Fz 6005 N N N Fx Fy Fz SIDE NOZZLE N N N Fx Fy Fz END NOZZLE EACH NOZZLE N N N Mx My Mz

BY MANUFACTURER OF PUMPS PER ASME B 73.1 OR B 73.2

CONSTRUCTION DATA (CONT'D) STUFFING BOX DATA


INBOARD / OUTBORAD

YDH

15568 12721 8006

1526 3465 3465

N.m N.m N.m

12010 14011

INSIDE DIAMETER DEPTH DISTANCE FACE OF STUFFING BOX FLANGE TO NEAREST OBSTRUCTION

mm mm mm

117.6/117.48 76.1 96

ISSUED FOR CONSTRUCTION

QTY. SIZE TYPE MISC CONNECTIONS LUBE OIL INLET LUBE OIL OUTLET SEAL LIQUID INLET SEAL LIQUID DRAIN 01 CASING DRAIN(S) 1/2" FLANGED VENTS COOLING WATER STUFFING BOX BALANCE DRUM DRAIN & VENT INDIVIDUALLY PIPED WITH BLOCK VALVES TO TERMINATE AT EDGE OF BASE PLATE IN COMMON AREA O YES O NO FLANGE RATING in CLASS

DESCRIPTION

IMPELLER DATA
NUMBER OF STAGES ONE mm ACTUAL DIAMETER mm MAXIMUM DIAMETER mm MINIMUM DIAMETER SINGLE / DOUBLE SUCTION cm2 EYE AREA IMPELLER O VANE ANGLE AT IMP. EXIT NUMBER OF VANES m/s ACTUAL PERIPHERAL SPEED m/s MAX.ALLOW.PERIPH.SP'D AT FLOW TEMP. PATTERN NUMBER YES - NO PRECISION CAST mm CUT WATER DIAMETER SPECIFIC SPEED SUCTION SPECIFIC SPEED AT 3% H mm WIDTH. IMPELLER DISCH. YES / NO UNDER / OVER FILING / V-CUT WEARING RINGS: YES NO IMPELLER CASE
YES NO mm mm FIRST STAGE FOLLOW STAGE

341.3 406.4 304.8 SINGLE 172

PRESSURES

MAX. ALLOW. WORK. PRESS. HYDROST. TEST PRESS.

O/

PRESSURES CASE JACKETS COILS DUAL MECH. SEAL

12-18-10

DATE

AT 50 kPa(ga) 1835 kPa(ga) kPa(ga) kPa(ga)

OC

2848


8010

JO/EWO

10-007950002

REV. NO.

00

DISCIPLINE ENGINEER CMM DATE: DEC 2010

SHAFT DATA
SHAFT DIAMETER AT MECH. SEAL SLEEVE SHAFT DIAMETER AT BEARINGS SHAFT DIAMETER AT 1ST STAGE IMPELLER BEARING SPAN STATIC SHAFT DEFLECTION
mm mm mm mm mm

66.67

CLEARANCE

INBOARD OUTBOARD

1st STAGE IMPELLER INLET GEOMETRY

PROJECT ENGINEER YDH DATE: DEC 2010

CERTIFIED
DCO DATE: DEC 2010

SHAFT SEALING
O PACKED STUFFING BOX PACKING MAT'L. PROVIDED WITH LANTERN RING: O YES O NO SEALING ARRANGEMENT THROUGH SEALING FLUSH WITH O MECHANICAL SEAL API CODE DEAD ENDED LIQUID PUMPED FOREIGN LIQUID
N/A

CONSTRUCTION AGENCY SHK DATE: DEC 2010 OPERATIONS YSY DATE: EDSD VERIFICATION DEC 2010 CONTROL NUMBER

GREASE BLEED OFF h

C1A1A CONFIG 1

O O
DATE:

BY:

MAKE MANUFACTURER MAT'L CODE 2CPX2750CCX05 MODEL API CODE MAT'L 3RD LETTER 4TH LETTER 5TH LETTER PIPING FOR PRIMARY SEAL API FIG. D-2 PLAN PIPING FOR THROTTLE BUSHING OR AUXILIARY SEAL API FIG. D-3 PLAN COOLING WATER PIPING, API FIG. D-4 PLAN CYCLONE SEPARATOR FLOW ORIFICE IN SEAL FLUSH SUPPLY LINE SEAL LEAKAGE PIPING WITH ORIFICE BUFFER LIQUID SYSTEM

Dh1

Dh2

Dsl

Dp

11/61 w/65 (See NOTE 5)

Dp Dsl O YES O YES O YES O YES O YES O YES O NO O NO O NO O NO O NO


L/s

= = = = = = =

mm mm (IF APPLICABLE) mm mm mm DEGREES DEGREES

REVISION VISION CERTIFICATION

APPROVAL/CERTIFICATION ROVAL/CERTIFICATION REQUIREMENTS,

(DCC) C) NO. 10-00795-0002-045 ____________________________

OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE

Dh1 Dh2 d p h

00

THIS S INDICATES THAT REV. NO.

METHANOL DRIP SYSTEM REQUIRED: PRESSURE CARTRIDGE DESIGN

kPa(ga); FLOW

O NO
DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.

DATA SHEET FOR

X12-G-0001 to 0016 + Warehouse Spare 0017 (Total 17 Pumps)

DIESEL LOADING PUMP WSASEA BULK PLANT WASEA

DAT

X12

VE-383373 E

SAUDI ARABIA JO :

10-00795-0002

2 of 4

00

EDSD/2741-M-2-0700.XLS

Saudi Aramco 2741-M-ENG (07/2000)


ENGG CERT PMT OPRNS
YSY

SAUDI ARABIAN OIL COMPANY


CENTRIFUGAL PUMP DATA SHEET FOR HORIZONTAL PUMPS AND VERTICAL IN-LINE PUMPS
O INDICATES INFORMATION TO BE COMPLETED BY PURCHASER; BY MANUFACTURER OF PUMPS OR PUMPS PER 31-SAMSS-004
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN N FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.

MMQ

NOTE: CONSTRUCTION DATA (CONT'D) BEARINGS AND LUBRICATION


BEARING TYPE SLEEVE ANTI-FRICTION TILTING PAD LUBRICATION METHOD GREASE RING-OIL CONSTANT LEVEL LUBRICATOR, MAKE OIL BATH WITH EXT'L CIRCULATION FORCED FEED OIL MIST LUBE OIL PIPING TO AND FROM BEARINGS LUBE OIL PIPING UP TO L.O. SYSTEM TERMINATION WITH FLANGED CONNECTIONS AT RADIAL COUPLING PLANE SIGHT FLOW INDICATOR IN EACH RETURN BRANCH MAKE THRUST BEARING LOADS: MAX. ALLOWABLE AXIAL FORCE: DESIGN AXIAL FORCE: RADIAL THRUST

BY MANUFACTURER OF PUMPS PER ASME B 73.1 OR B 73.2

DCO

CONSTRUCTION DATA (CONT'D) COUPLING


MAKE JOHNCRANE MODEL TSKS SIZE 130mm SUPPLIED BY: VENDOR TYPE O DIAPHRAGM O DISC PACK O RIGID ADJUSTABLE O CLOSE COUPLED O ELASTOMERIC HYDRAULIC FIT KEYED SPACER: mm O NO O YES, COUPLING GUARD O PARTIALLY ENCLOSED O COMPLETELY ENCLOSED PUMP SHAFT END CYLINDRICAL TAPERED MOUNT COUPLING HALF: PUMP YES NO DRIVER HALF NO. IF SHIPPED TO DRIVER SUPPLIER YES PILOT BORED COMPLETELY MACHINED

YDH

RADIAL

THRUST

DESCRIPTION

ISSUED FOR CONSTRUCTION

YES YES

NO NO

YES MODEL

NO

BASE PLATE
O O N N O OIL FIELD SKID BASE PLATE SUPPLIED BY VENDOR O GEAR O PUMP TO ACCOMMODATE: O DRIVER O L.O. AND/OR S.O. SYSTEM MOUNTED O ON BASE O OFF BASE DESIGNED FOR INSTALLATION ON: O CONCRETE FOUNDATION O STEEL PLATFORM DRILLED FOR DRIVER O YES O NO O NO GEAR O YES HORIZONTAL ALIGNMENT JACKSCREWS O YES O NO

JO/EWO

10-007950002

LUBRICANTS
O BEARING LUBRICANT OIL PER 26-SAMSS-045 O GREASE PER 26-SAMSS-054

12-18-10

DATE

MATERIALS OF CONSTRUCTION
FLOW OR CAPACITY L/s;L INB. BRG. OUTB. BRG. THRUST BRG. SUPPLY PRESSURE kPa(ga) HEAT REMOVAL kJ MAX. OIL OUTL. TP.
OC

REV. NO.

DISCIPLINE ENGINEER CMM DATE: DEC 2010 PROJECT ENGINEER YDH DATE: DEC 2010

00

TOTAL O PUMP VENDOR O OTHER IN ACCORDANCE WITH DATA SHEET FORM 8004-ENG YES, DRAWING NO. O NO LUBE OIL SYSTEM SUPPLIED BY:

MATERIALS TO BE IN ACC. WITH CODE HKA2 OF STD. DRAWING AC-036821 VENDOR TO COMPLETE FOLLOWING MAT'L LISTING 744CF8M 1. CASING ASTM 2. IMPELLER(S) CF8M ASTM N/A 3. CASE WEAR RINGS ASTM 4. IMPELLER WEAR RINGS ASTM N/A ASTM 5. SHAFT SS316 ASTM 6. SHAFT SLEEVES 7. 8. 9. 10. 11. 12. 13.1 13.2 14. 15. 16. 17. 18. 19. THROAT BUSHINGS INTERSTAGE SLEEVES INTERSTAGE BUSHINGS LANTERN RING (PACKED PUMPS) GLAND / MECH. SEAL FLANGE BEARING BRACKETS NON-WETTED STUDS / NUTS WETTED FASTENERS PIPING: PIPE / FITTINGS BASE PLATE MECH. SEAL SPRINGS MECH. SEAL OTHER METAL PARTS ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM

CERTIFIED
DCO DATE: DEC 2010

COOLING
BEARING COOLING NON-CIRCULATING SYSTEM BY: SHAFT MOUNTED FAN COILS IN BEARING HOUSING EXTERNAL CIRCULATING SYSTEM OIL COOLING BY: LIQ. PUMPED FOREIGN LIQ. STUFFING BOX COOLING PEDESTAL COOLING COOLING PIPING FOR BEARINGS STUF. BOX IN ACCORDANCE WITH API-610. FIG. D-4. PLAN

CONSTRUCTION AGENCY SHK DATE: DEC 2010

JACKETED BEARING HOUSING

OPERATIONS
YSY DATE: DEC 2010 CONTROL NUMBER EDSD VERIFICATION

AIR YES YES PEDESTALS

NONE NO NO SEAL COOLER

NOISE SPECIFICATION

DATE:

BY:

COOLANT DATA

O BRG HSG L/s kPa(ga)


OC OC

STUF BOX

PEDESTAL

SEAL COOLER

MAXIMUM ALLOWABLE SOUND LEVEL BY PURCHASER AT 1 m DISTANCE MANUFACTURER GUARANTEED MAXIMUM PUMP DRIVER OTHER COMPLETE TRAIN

85

dBA dBA dBA dBA

REVISION VISION CERTIFICATION

APPROVAL/CERTIFICATION ROVAL/CERTIFICATION REQUIREMENTS,

(DCC) C) NO. 10-00795-0002-045 ______________________________

00

TOTAL FLOW INLET PRESS. TEMP. INLET TEMP. OUTLET COOLING MEDIUM
DATA SHEET FOR

OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE

THIS S INDICATES THAT REV. NO.

85

dBA

X12-G-0001 TO 0016 + Warehouse Spare 0017 (Total 17 Pumps)

DWG. TYPE

PLANT NO.

INDEX

DRAWING NO.

SHT.NO.

REV.NO.

DIESEL LOADING PUMP WASEA BULK PLANT WASEA

DAT

X12

VE G VE-383773
10-00795-0002

SAUDI ARABIA JO :

3 of 4

00

EDSD/2741-M-3-0700.XLS

Saudi Aramco 2741-M-ENG (07/2000)


ENGG CERT PMT OPRNS
YSY

SAUDI ARABIAN OIL COMPANY


CENTRIFUGAL PUMP DATA SHEET FOR HORIZONTAL PUMPS AND VERTICAL IN-LINE PUMPS
BY MANUFACTURER OF PUMPS OR PUMPS PER 31-SAMSS-004
THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.

MMQ

DCO

NOTE: O INDICATES INFORMATION TO BE COMPLETED BY PURCHASER; UTILITIES


O ELECTRIC POWER AC DC MAIN ELECTRIC DRIVER CONTROLS AND PROTECTION O AIR CONTROLS AND PROTECTION AC AVAILABLE VOLTS 480 PHASE HZ 3/60

BY MANUFACTURER OF PUMPS PER ASME B 73.1 OR B 73.2

INSPECTION AND TESTS


OBSER'D WITN'D O VENDOR'S STANDARD SHOP TEST O AS FOLLOWS HYDROSTATIC TEST O WATER RUNNING TEST AVAILABLE kPa(ga) PERFORMANCE TEST MEASURE P ACROSS STUFFING BOX NPSH TEST DISMANTLING RADIOGRAPHIC INSPECTION IMPELLER DYE PENETRANT EXAMINATION IMPELLER O KEROSENE CERT'D O O O O O O O O O O O O O

YDH

O O O O O O O O O O O O O

O O O O O O O O O O O O O

DESCRIPTION

10-00795ISSUED FOR CONSTRUCTION 0002

AVAIL COOLING WATER

AVAIL kPa(ga) N/A

INLET OC

OUTLET OC

REQ'D OC

DYNAMIC BALANCE IMPELLER(S) DYNAMIC BALANCE ROTOR DYNAMIC BALANCE COUPLING VIBRATION, MEASUREMENTS TESTS TO BE CARRIED WITH: O ACTUAL DRIVER AT O RATED SPEED O MANUFACTURER'S DRIVER O DERATED SPEED:

O TREATED WATER O SEA WATER O WELL WATER O CLOSED LOOP SYSTEM O ONCE THROUGH SYSTEM Motor AmbientTemperature Shallbe50o C,MinimumNo.ofstartsperHr.shallbe3

INSTRUMENTATION & CONTROLS

RPM

DRAWINGS AND OTHER DATA


TEMPERATURE MONITORING YES PROVISIONS ONLY ALARM SETTING SHUTDOWN SETTING
OC OC

JO/EWO

RADIAL BEARINGS O O

THRUST BEARINGS O O

CASING THERMOWELL O O

MANUFACTURER'S DRAWING OR DOCUMENT NO. REQUIRED YES NO DIMENSIONAL DRAWING OF COMPLETELY ASSEMBLED UNIT OPER. & MAINT. INSTRUCTIONS CROSS SECT SECT. DRW DRW. WITH PART NO'S NO'S. MECHANICAL SEAL DRAWING BILLS OF MATERIALS COMPLETED PUMP DATA SHEET AUXILIARY PIPING DWG. CERTIFIED TEST CURVE & DATA RECOMMENDED SPARES LIST INSTR. WIRING DIAGRAM SPEED TORQUE CURVE COLD ALIGNMENT CURVE DATA L. & T. VIBR. ANALYSIS O O O O O O O O O O O O O O O O O O O O O O O O O O

REV. NO.

00

12-18-10

DATE

VIBRATION / DISPLACEMENT MONITORING POSITION TYPE RADIAL BRG'S THRUST BRG. PROXIMITY PROXIMITY O O O O BRG. HSG SEISMIC O O

DISCIPLINE ENGINEER CMM DATE: DEC 2010 PROJECT ENGINEER YDH DATE: DEC 2010

YES PROVISIONS ONLY ALARM / SHUTDOWN m P-P SETTING: mm/s RMS

/ / /

CERTIFIED
DCO DATE: DEC 2010

O SEISMIC O PROXIMITY

O PNEUMATIC O ELECTRICAL O YES O PNEUMATIC MODEL kPa(ga) MODEL CONTR.ORIFICE mm O NO PAINTING

MISCELLANEOUS

CONSTRUCTION AGENCY SHK DATE: DEC 2010

SHAFT SEAL LEAKAGE CONTROL: O ELECTRICAL

O BUYER'S PAINT SPECIFICATION: O VENDOR'S STANDARD:

APCS- 26 (SAES-H-100/101)

OPERATIONS
YSY DATE: DEC 2010 CONTROL NUMBER EDSD VERIFICATION

PRES. SWITCH MAKE PRESSURE SETTING *SHUTDOWN* LEVEL SWITCH MAKE TIME DELAY SETTING

SPECIFICATION

MASSES

DATE: BY:

PUMPS TO BE IN ACCORDANCE WITH: O 31-AMSS-004

PUMP PUMP ROTATING ASSEMBLY CASING (UPPER HALF) BASEPLATE COUPLING DRIVER DRIVER ROTATING ASSEMBLY TOTAL MASS

kg kg kg kg kg kg kg kg

320

O ASME B 73.1 O

O ASME B 73.2

REVISION VISION CERTIFICATION

APPROVAL/CERTIFICATION ROVAL/CERTIFICATION REQUIREMENTS,

(DCC) C) NO. 10-00795-0002-045 ______________________________

OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE

524

1. PUMPS MAY BE SUBJECT TO ON/OFF CYCLING 12 TO 15 CYCLES/HOUR 2. VENDOR TO VERIFY THE NPSH AVAILABLE AGAINST NPSH REQUIRMENTS AND SELECT THE PUMP DESIGN TO ACCOMMODATE THE NPSH AVAILABLE. 3. ALL THE BLANK COLUMN SHALL BE FILLED IN BY THE VENDOR. 4. PROVIDE JACK SCREWS FOR HORIZONTAL ALIGNMENT. 5. This data sheet to be updated after recieving final Vendor Data Sheet

THIS S INDICATES THAT REV. NO.

00

DATA SHEET FOR

X12-G-0001 TO 0016 + WarehouseSpare 0017 (Total 17 Pumps)

DWG. TYPE

PLANT NO.

INDEX

DRAWING NO.

SHT.NO.

REV.NO.

DIESEL LOADING PUMP WASEA BULK PLANT WASEA

DAT

X12

VE-383773 E G V
10-00795-0002

SAUDI ARABIA JO :

4 of 4

00

EDSD/2741-M-4-0700.XLS

NONE O O O O O O O O O O O O O