SITE CONDITIONS
INDOOR ON SHORE ELECTRICAL AREA CLASS OUTDOOR COASTAL 1 , DIV. UNDER ROOF OFF SHORE , GROUP 2 IIA
YDH
FLOWSERVE 3K6X416RVM3ST
ELECTRIC MOTOR X12 SEVENTEEN (17) PUMP(S) -G- 0001 to 0017 , , -G-
1775 55
RPM 100% 120%
DESCRIPTION
PUMPS OF IDENTICAL TYPE & SIZE IN OPERATION -G, -G, DRIVER DATA SHEET GEAR UNIT DATA SHEET N/A
ISSUED FOR CONSTRUCTION
PERFORMANCE AT m TOTAL DIFF. HEAD % EFFICIENCY REQUIRED POWER kW NPSH REQ'D FOR: 3% 1st STAGE ON H2O m 40,000 HRS LIQ'D PUMPED m
LUBE OIL SYST DATA SHEET SAFETY INSTRUCTION SHEET LCC EF N/A $/kW
N/A
SERVICE
PUMP FUNCTION CONTINUOUS ATTENDED INDIVIDUALLY DIESEL LOADING PUMP INTERMITTENT UNATTENDED IN SERIES N/A N/A DOWNSTREAM OF PUMP NO(S) N/A N/A IN PARALLEL -G-G-G-GSTANDY BY
REV. NO.
LIQUID CHARACTERISTICS
LIQUID PUMPED DIESEL TDS
OC OC
mg/L
NORMAL FLOW TEMPERATURE MAX. FLOW TEMPERATURE RELATIVE DENSITY AT NORMAL FLOW TEMP. VISCOSITY AT FLOW TEMP. VAPOR PRESSURE AT NORMAL FLOW TEMP. V.P. AT MAX. FLOW TEMP. TSS NONE N/A PULPY VOL. %
SHUT-OFF HEAD AT ACTUAL IMP. DIAM. m AT MAX. IMP. DIAM. m L/s CAPACITY AT END OF CURVE TOT.DIFF. HEAD AT END OF CURVE m RATIO. SHUT-OFF HEAD/RATED HEAD RATIO. END OF CURVE CAPACITY/RATED L/s MINIMUM CONTINUOUS STABLE FLOW L/s MINIMUM CONTINUOUS THERMAL FLOW s MAXIMUM OPERATING TIME AT SHUT-OFF FIRST CRIT. SPEED; DRY RPM FIRST CRIT. SPEED; WET RPM MAX. ALLOWABLE SPEED RPM MAX. POWER FULL CURVE ACTUAL IMP.DIAM. kW POWER AT SHUT-OFF HEAD kW PERFORMANCE WITH MAX. AND MIN. IMPELLER DIAMETERS TOT.DIFF. HEAD AT RATED CAPACITY EFFICIENCY AT RATED CAPACITY REQUIRED POWER AT RATED CAP. MAX. REQUIRED POWER FULL CURVE / / INTERMEDIATE TRANSMISSION GEAR BOX HYDR. COUPL. SPEED RANGE MAX. 84.5 68 77.5 113
JO/EWO
10-007950002
12-18-10
DATE
6990
00
Mpa.s, mm2/s
MIN.
34.67
m % kW kW
CERTIFIED
DCO DATE: DEC 2010
66.5 32 34.2
OPERATIONS
YSY DATE: EDSD VERIFICATION DEC 2010 CONTROL NUMBER
OPERATING CONDITIONS
CAPACITY RATED TOTAL DIFFERENTIAL HEAD NPSH AVAILABLE AT SUCTION FLG. AT RATED CAPACITY AT 120% OF RATED CAPACITY
DATE:
HORIZONTAL (BET. BRGS) VERT. IN-LINE CASING MOUNT: CENTERLINE FOOT VERT. IN-LINE IN-LINE CASING SPLIT CASING TYPE SELF PRIMING AXIAL DOUBLE VOLUTE DIFFUSOR YES
OVERHUNG INTEGRAL SHAFT FLANGE CENTERLINE CASE SUPPORTED RADIAL SINGLE VOLUTE STAGGER NO CW
m m
VISC. CORR. FACTOR CQ; CH; CE RATED SUCTION PRESSURE MAX. SUCT. PR. AT RATED CAP.
BY:
00
MAX. SUCT. PR. AT SHUT-OFF TOTAL DIFFERENTIAL PRESSURE RATED DISCHARGE PRESSURE MAX. DISCH. PR. AT RATED CAP.
DATA SHEET FOR
PUMP NOZZLES
SUCTION DISCHARGE SIZE 6.00" 4.00" RATING 150# 150# FACING RF RF LOCATION END TOP
DWG. TYPE
PLANT NO.
INDEX
DRAWING NO.
SHT.NO.
REV.NO.
DAT
SAUDI ARABIA
X12
JO / EWO:
VE-383773 E
10-00795-0002
1 OF 4
00
EDSD/2741-M-1-0801.XLS
MMQ
DCO
NOTE: O INDICATES INFORMATION TO BE COMPLETED BY PURCHASER; CONSTRUCTION DATA (CONT'D) FORCES AND MOMENTS
ALLOWABLE FORCES AND MOMENTS
TOP NOZZLE Fx Fy Fz 6005 N N N Fx Fy Fz SIDE NOZZLE N N N Fx Fy Fz END NOZZLE EACH NOZZLE N N N Mx My Mz
YDH
12010 14011
INSIDE DIAMETER DEPTH DISTANCE FACE OF STUFFING BOX FLANGE TO NEAREST OBSTRUCTION
mm mm mm
117.6/117.48 76.1 96
QTY. SIZE TYPE MISC CONNECTIONS LUBE OIL INLET LUBE OIL OUTLET SEAL LIQUID INLET SEAL LIQUID DRAIN 01 CASING DRAIN(S) 1/2" FLANGED VENTS COOLING WATER STUFFING BOX BALANCE DRUM DRAIN & VENT INDIVIDUALLY PIPED WITH BLOCK VALVES TO TERMINATE AT EDGE OF BASE PLATE IN COMMON AREA O YES O NO FLANGE RATING in CLASS
DESCRIPTION
IMPELLER DATA
NUMBER OF STAGES ONE mm ACTUAL DIAMETER mm MAXIMUM DIAMETER mm MINIMUM DIAMETER SINGLE / DOUBLE SUCTION cm2 EYE AREA IMPELLER O VANE ANGLE AT IMP. EXIT NUMBER OF VANES m/s ACTUAL PERIPHERAL SPEED m/s MAX.ALLOW.PERIPH.SP'D AT FLOW TEMP. PATTERN NUMBER YES - NO PRECISION CAST mm CUT WATER DIAMETER SPECIFIC SPEED SUCTION SPECIFIC SPEED AT 3% H mm WIDTH. IMPELLER DISCH. YES / NO UNDER / OVER FILING / V-CUT WEARING RINGS: YES NO IMPELLER CASE
YES NO mm mm FIRST STAGE FOLLOW STAGE
PRESSURES
O/
12-18-10
DATE
OC
2848
8010
JO/EWO
10-007950002
REV. NO.
00
SHAFT DATA
SHAFT DIAMETER AT MECH. SEAL SLEEVE SHAFT DIAMETER AT BEARINGS SHAFT DIAMETER AT 1ST STAGE IMPELLER BEARING SPAN STATIC SHAFT DEFLECTION
mm mm mm mm mm
66.67
CLEARANCE
INBOARD OUTBOARD
CERTIFIED
DCO DATE: DEC 2010
SHAFT SEALING
O PACKED STUFFING BOX PACKING MAT'L. PROVIDED WITH LANTERN RING: O YES O NO SEALING ARRANGEMENT THROUGH SEALING FLUSH WITH O MECHANICAL SEAL API CODE DEAD ENDED LIQUID PUMPED FOREIGN LIQUID
N/A
CONSTRUCTION AGENCY SHK DATE: DEC 2010 OPERATIONS YSY DATE: EDSD VERIFICATION DEC 2010 CONTROL NUMBER
C1A1A CONFIG 1
O O
DATE:
BY:
MAKE MANUFACTURER MAT'L CODE 2CPX2750CCX05 MODEL API CODE MAT'L 3RD LETTER 4TH LETTER 5TH LETTER PIPING FOR PRIMARY SEAL API FIG. D-2 PLAN PIPING FOR THROTTLE BUSHING OR AUXILIARY SEAL API FIG. D-3 PLAN COOLING WATER PIPING, API FIG. D-4 PLAN CYCLONE SEPARATOR FLOW ORIFICE IN SEAL FLUSH SUPPLY LINE SEAL LEAKAGE PIPING WITH ORIFICE BUFFER LIQUID SYSTEM
Dh1
Dh2
Dsl
Dp
= = = = = = =
Dh1 Dh2 d p h
00
kPa(ga); FLOW
O NO
DWG. TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
DAT
X12
VE-383373 E
SAUDI ARABIA JO :
10-00795-0002
2 of 4
00
EDSD/2741-M-2-0700.XLS
MMQ
DCO
YDH
RADIAL
THRUST
DESCRIPTION
YES YES
NO NO
YES MODEL
NO
BASE PLATE
O O N N O OIL FIELD SKID BASE PLATE SUPPLIED BY VENDOR O GEAR O PUMP TO ACCOMMODATE: O DRIVER O L.O. AND/OR S.O. SYSTEM MOUNTED O ON BASE O OFF BASE DESIGNED FOR INSTALLATION ON: O CONCRETE FOUNDATION O STEEL PLATFORM DRILLED FOR DRIVER O YES O NO O NO GEAR O YES HORIZONTAL ALIGNMENT JACKSCREWS O YES O NO
JO/EWO
10-007950002
LUBRICANTS
O BEARING LUBRICANT OIL PER 26-SAMSS-045 O GREASE PER 26-SAMSS-054
12-18-10
DATE
MATERIALS OF CONSTRUCTION
FLOW OR CAPACITY L/s;L INB. BRG. OUTB. BRG. THRUST BRG. SUPPLY PRESSURE kPa(ga) HEAT REMOVAL kJ MAX. OIL OUTL. TP.
OC
REV. NO.
DISCIPLINE ENGINEER CMM DATE: DEC 2010 PROJECT ENGINEER YDH DATE: DEC 2010
00
TOTAL O PUMP VENDOR O OTHER IN ACCORDANCE WITH DATA SHEET FORM 8004-ENG YES, DRAWING NO. O NO LUBE OIL SYSTEM SUPPLIED BY:
MATERIALS TO BE IN ACC. WITH CODE HKA2 OF STD. DRAWING AC-036821 VENDOR TO COMPLETE FOLLOWING MAT'L LISTING 744CF8M 1. CASING ASTM 2. IMPELLER(S) CF8M ASTM N/A 3. CASE WEAR RINGS ASTM 4. IMPELLER WEAR RINGS ASTM N/A ASTM 5. SHAFT SS316 ASTM 6. SHAFT SLEEVES 7. 8. 9. 10. 11. 12. 13.1 13.2 14. 15. 16. 17. 18. 19. THROAT BUSHINGS INTERSTAGE SLEEVES INTERSTAGE BUSHINGS LANTERN RING (PACKED PUMPS) GLAND / MECH. SEAL FLANGE BEARING BRACKETS NON-WETTED STUDS / NUTS WETTED FASTENERS PIPING: PIPE / FITTINGS BASE PLATE MECH. SEAL SPRINGS MECH. SEAL OTHER METAL PARTS ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM ASTM
CERTIFIED
DCO DATE: DEC 2010
COOLING
BEARING COOLING NON-CIRCULATING SYSTEM BY: SHAFT MOUNTED FAN COILS IN BEARING HOUSING EXTERNAL CIRCULATING SYSTEM OIL COOLING BY: LIQ. PUMPED FOREIGN LIQ. STUFFING BOX COOLING PEDESTAL COOLING COOLING PIPING FOR BEARINGS STUF. BOX IN ACCORDANCE WITH API-610. FIG. D-4. PLAN
OPERATIONS
YSY DATE: DEC 2010 CONTROL NUMBER EDSD VERIFICATION
NOISE SPECIFICATION
DATE:
BY:
COOLANT DATA
STUF BOX
PEDESTAL
SEAL COOLER
MAXIMUM ALLOWABLE SOUND LEVEL BY PURCHASER AT 1 m DISTANCE MANUFACTURER GUARANTEED MAXIMUM PUMP DRIVER OTHER COMPLETE TRAIN
85
00
TOTAL FLOW INLET PRESS. TEMP. INLET TEMP. OUTLET COOLING MEDIUM
DATA SHEET FOR
85
dBA
DWG. TYPE
PLANT NO.
INDEX
DRAWING NO.
SHT.NO.
REV.NO.
DAT
X12
VE G VE-383773
10-00795-0002
SAUDI ARABIA JO :
3 of 4
00
EDSD/2741-M-3-0700.XLS
MMQ
DCO
YDH
O O O O O O O O O O O O O
O O O O O O O O O O O O O
DESCRIPTION
INLET OC
OUTLET OC
REQ'D OC
DYNAMIC BALANCE IMPELLER(S) DYNAMIC BALANCE ROTOR DYNAMIC BALANCE COUPLING VIBRATION, MEASUREMENTS TESTS TO BE CARRIED WITH: O ACTUAL DRIVER AT O RATED SPEED O MANUFACTURER'S DRIVER O DERATED SPEED:
O TREATED WATER O SEA WATER O WELL WATER O CLOSED LOOP SYSTEM O ONCE THROUGH SYSTEM Motor AmbientTemperature Shallbe50o C,MinimumNo.ofstartsperHr.shallbe3
RPM
JO/EWO
RADIAL BEARINGS O O
THRUST BEARINGS O O
CASING THERMOWELL O O
MANUFACTURER'S DRAWING OR DOCUMENT NO. REQUIRED YES NO DIMENSIONAL DRAWING OF COMPLETELY ASSEMBLED UNIT OPER. & MAINT. INSTRUCTIONS CROSS SECT SECT. DRW DRW. WITH PART NO'S NO'S. MECHANICAL SEAL DRAWING BILLS OF MATERIALS COMPLETED PUMP DATA SHEET AUXILIARY PIPING DWG. CERTIFIED TEST CURVE & DATA RECOMMENDED SPARES LIST INSTR. WIRING DIAGRAM SPEED TORQUE CURVE COLD ALIGNMENT CURVE DATA L. & T. VIBR. ANALYSIS O O O O O O O O O O O O O O O O O O O O O O O O O O
REV. NO.
00
12-18-10
DATE
VIBRATION / DISPLACEMENT MONITORING POSITION TYPE RADIAL BRG'S THRUST BRG. PROXIMITY PROXIMITY O O O O BRG. HSG SEISMIC O O
DISCIPLINE ENGINEER CMM DATE: DEC 2010 PROJECT ENGINEER YDH DATE: DEC 2010
/ / /
CERTIFIED
DCO DATE: DEC 2010
O SEISMIC O PROXIMITY
MISCELLANEOUS
APCS- 26 (SAES-H-100/101)
OPERATIONS
YSY DATE: DEC 2010 CONTROL NUMBER EDSD VERIFICATION
PRES. SWITCH MAKE PRESSURE SETTING *SHUTDOWN* LEVEL SWITCH MAKE TIME DELAY SETTING
SPECIFICATION
MASSES
DATE: BY:
PUMP PUMP ROTATING ASSEMBLY CASING (UPPER HALF) BASEPLATE COUPLING DRIVER DRIVER ROTATING ASSEMBLY TOTAL MASS
kg kg kg kg kg kg kg kg
320
O ASME B 73.1 O
O ASME B 73.2
524
1. PUMPS MAY BE SUBJECT TO ON/OFF CYCLING 12 TO 15 CYCLES/HOUR 2. VENDOR TO VERIFY THE NPSH AVAILABLE AGAINST NPSH REQUIRMENTS AND SELECT THE PUMP DESIGN TO ACCOMMODATE THE NPSH AVAILABLE. 3. ALL THE BLANK COLUMN SHALL BE FILLED IN BY THE VENDOR. 4. PROVIDE JACK SCREWS FOR HORIZONTAL ALIGNMENT. 5. This data sheet to be updated after recieving final Vendor Data Sheet
00
DWG. TYPE
PLANT NO.
INDEX
DRAWING NO.
SHT.NO.
REV.NO.
DAT
X12
VE-383773 E G V
10-00795-0002
SAUDI ARABIA JO :
4 of 4
00
EDSD/2741-M-4-0700.XLS
NONE O O O O O O O O O O O O O