Chemical Engineering September 2012

Download as pdf or txt
Download as pdf or txt
You are on page 1of 88

September 2012

THIN-FILM DRYING

PAGE 40

www.che.com

PAGE 34

New Valve Technology Vacuum Systems Plant Security Cooling Water Reciprocating Compressors Focus on Flowmeters Facts at Your Fingertips: Gas Sparging

Chemical. Petrochemical. Refining.

3rd Annual

November 14 - 15, 2012


ERNEST N. MORIAL CONVENTION CENTER

NEW ORLEANS, LA
Access and Learn About the CPI Building Boom Being Driven by Unconventional Natural-Gas Supplies
A First Look at the Technologies Driving the Future : See, demo and compare leading-edge solutions from 150+ exhibits. Learn objectively about the latest technological breakthroughs for the CPI , In the Chementator Lightning Round, Chemical Engineering editors will interview various technology providers and ask them the questions you really want to know: What makes this different from existing technologies, how does it work, what are the advantages, and so on. Unparalleled Networking Opportunities : Connect with thousands ofattendees across all exhibit floors Numerous events, one trade show: ChemInnovations, Shale EnviroSafe, CLEAN GULF, and Industrial Fire, Safety & Security. Talk one-on-one with CPI leaders and technical experts about the latest and issues technologies and get a glimpse of the future from the people that are shaping it. Four Conference Tracks including Fundamentals, Emerging Issues, Process Design & Optimization, and Controls & Automation.

P R E S E N T E D B Y:

www.cpievent.com

KEYNOTE PRESENTATIONS

The Evolving Shale Landscape, Wednesday, November 14


Two industry experts address the environmental and regulatory issues, as well as the economic impacts of unconventional oil and gas drilling one week following the Presidential election.
Moderator: Rebekkah Marshall, Editor-in-Chief, Chemical Engineering
SPEAKERS:

The Shale Gas Prize and Its Politics: The Risks and Rewards for our Environment
John Hanger, Special Counsel, Eckert Seamans

Shale Gas: A Game Changer Impacts for American Chemistry, Manufacturing & U.S. Economy Martha Gilchrist Moore, Sr. Director for Policy Analysis & Economics, American Chemistry Council

Plant Manager Roundtable, Thursday, November 15


Moderator: Rebekkah Marshall, Editor-in-Chief, Chemical Engineering
PANELISTS:

Jim Armstrong, Operations Manager, Rhodia, Inc. - Baton Rouge Paresh Bhakta*, Site Director, Clear Lake Plant, Celanese Ltd. Jim Hull, Vice President - Manufacturing, Georgia Gulf Chemicals and Vinyls, LLC
* Denotes Invited Panelists

SPECIAL DISCOUNT FOR CHEMICAL ENGINEERING SUBSCRIBERS: REGISTER TODAY at www.cpievent.com with VIP code CHEMENG9 to qualify for Advanced Discounts on the conference!

W ER E EN H A N C I N G T HE

O F S T R E N G T H.

Corzan Industrial Systems get their strength from our science. Thats because The Lubrizol Corporations superior CPVC compounds create every Corzan pipe and tting. With the power of mechanical strength and corrosion resistance, Corzan pipe and ttings exceed the demands of industrial and commercial applications. Plus, every Corzan system has delivered MORE INSIDE for more than 20 years giving you access to Lubrizols unmatched R&D, technical expertise, global capabilities and a network of customers who are industry-leading manufacturers.

Enhance the strength of your next industrial job. Visit corzancpvc.com or call a piping systems consultant at 1.855.735.1431.

The Lubrizol Corporation 2012, all rights reserved. All marks are property of The Lubrizol Corporation, a Berkshire Hathaway Company. GC 121100

Circle 20 on p. 72 or go to adlinks.che.com/40271-20

SEPTEMBER 2012

IN THIS ISSUE

VOLUME 119, NO. 9 COMMENTARY

5 Editors Page
Opinions on ChE education Comments stemming from a recent CE story on education underscore a modern industry challenge: a higher percentage of less experienced engineers

www.che.com COVER STORY

34 Cover Story Condition


Monitoring Methods for Pumps Applying condition monitoring tests to pumps can save costs by optimizing overhaul scheduling NEWS

68 The Fractionation Column Try harder to stay awake A cautionary tale from the FRI technical director on falling asleep during meetings DEPARTMENTS Letters . . . . . . . . . . . 6 Bookshelf . . . . . . . 89 Whos Who . . . . . . . 74 Reader Service . . . . 72 Economic Indicators . . . . . 7576 ADVERTISERS Product Showcase. . 69 Classified Advertising . . . . 7071 Advertiser Index . . . 73 COMING IN OCTOBER Look for: Feature Reports on Batch to Continuous Processing; and Acid Handling; an Environmental Manager article on Safety Considerations for Vacuum Systems; a Solids Processing article on Blending, Segregation and Testing; a Focus on Gas Detection; News articles on Ethylene Feedstocks; and Steam Handling; and more Cover: David Whitcher
3

11 Chementator A commercial
move toward algae farming for CO2 recovery; This osmium-based catalyst is rendered nontoxic by polymer incarceration; Strainhardening test method speeds HDPE pipe testing; A hightemperature Fischer-Tropsch process demonstrated in China; and more

ONLY ON CHE.COM
More recently published books; More flowmeter focus items; New Products; Latest news and more

17 Newsbriefs EPA evaluates


alternatives to a toxic flameretardant chemical; Report on biobased chemicals from algae and other sources; CSB deploys team to Chevron accident; and more

51 Engineering Practice Reciprocating


Compressors: Startup and Capacity Control Methods Procedures and guidelines that will help operators minimize energy consumption and maintenance requirements of compressor systems

18 Newsfront Chemical Plant Security:


Gating More Than the Perimeter Cyber security and physical security are now considered to be interdependent

24 Newsfront An Open-and-Shut Case


Improvements in valve technology allow processors to improve performance while reducing leaks ENGINEERING

59 Environmental Manager Vacuum


Systems: Recommendations for Safe Operation Follow this guidance to ensure that steam-ejector systems, mechanical vacuum pumps and integrated vacuum systems are designed, operated and maintained to ensure process safety EQUIPMENT & SERVICES

33 Facts at Your Fingertips Gas Sparging


This one-page reference guide discusses major considerations in setting up and operating a gas-sparging system

29 Focus on Flowmeters A flowmeter


designed for biogas; A wide choice of power solutions for this flowmeter; Minimize pressure drop with this mass-flow device; This flowmeter has a direct-mount configuration; and more

40 Feature Report Thin-Film Drying


Offers Deep Benefits This continuous drying technology is especially safe and flexible, and offers many benefits, including low operating costs, low space requirements and high specific evaporation capacity

32I-1 New Products (International


edition) A retractable assembly for sterile pH measurements; This new pastillation machine requires less maintenance; Leaks are minimized in this AODD pump; A hygienic actuator that requires less space; Aseptic globe valves for pure steam applications; and more

46 Engineering Practice Cooling-Water


Outlet Temperature This article discusses the evaluation process and tradeoffs that must be considered to optimize recirculating cooling-water systems

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Every single flowmeter I calibrate interrupts my process. There must be a way to verify meters without putting my plant and people at risk.

YOU CAN DO THAT

Verify flowmeter performance in place with Micro Motion Smart Meter Verification. Determining measurement integrity and performance of every meter in line means never stopping your process flow. Emersons Smart Meter Verification for Micro Motion Coriolis meters is the only automatic diagnostic tool that eliminates the need to break process seals, allowing you to avoid potential safety issues and costly process flow interruptions. So to keep your workers safe and your operation running, go to EmersonProcess.com/Verification

The Emerson logo is a trademark and a service mark of Emerson Electric Co. 2011 Emerson Electric Co.

Circle 21 on p. 72 or go to adlinks.che.com/40271-21

Winner of Eight Jesse H. Neal Awards for Editorial Excellence

Editors Page

Published since 1902


An Access Intelligence Publication
PUBLISHER ART & DESIGN

Opinions on ChE education

BRIAN NESSEN
Group Publisher [email protected] EDITORS

DAVID WHITCHER
Art Director/ Editorial Production Manager [email protected] PRODUCTION

REBEKKAH J. MARSHALL
Editor in Chief [email protected]

STEVE OLSON
Director of Production & Manufacturing [email protected]

DOROTHY LOZOWSKI
Managing Editor [email protected]

GERALD ONDREY (Frankfurt)


Senior Editor [email protected]

JOHN BLAYLOCK-COOKE
Ad Production Manager [email protected] AUDIENCE DEVELOPMENT

SCOTT JENKINS
Associate Editor [email protected] CONTRIBUTING EDITORS

SARAH GARWOOD
Audience Marketing Director [email protected]

SUZANNE A. SHELLEY
[email protected]

CHARLES BUTCHER (U.K.)


[email protected]

GEORGE SEVERINE
Fulfillment Manager [email protected]

PAUL S. GRAD (Australia)


[email protected]

JEN FELLING
List Sales, Statlistics (203) 778-8700 [email protected] EDITORIAL ADVISORY BOARD

TETSUO SATOH (Japan)


[email protected]

JOY LEPREE (New Jersey)


[email protected]

GERALD PARKINSON
(California) [email protected] INFORMATION SERVICES

JOHN CARSON
Jenike & Johanson, Inc.

DAVID DICKEY
MixTech, Inc.

CHARLES SANDS
Senior Developer Web/business Applications Architect [email protected] MARKETING

MUKESH DOBLE
IIT Madras, India

HENRY KISTER
Fluor Corp.

JAMIE REESBY
Marketing Director TradeFair Group, Inc. [email protected]

TREVOR KLETZ
Loughborough University, U.K.

JENNIFER BRADY
Marketing Coordinator TradeFair Group, Inc. [email protected] HEADQUARTERS

GERHARD KREYSA (retired)


DECHEMA e.V.

RAM RAMACHANDRAN
(Retired) The Linde Group

88 Pine Street, 5th Floor, New York, NY 10005, U.S. Fax: 212-621-4694 Tel: 212-621-4900 EUROPEAN EDITORIAL OFFICES Zeilweg 44, D-60439 Frankfurt am Main, Germany Tel: 49-69-9573-8296 Fax: 49-69-5700-2484 CIRCULATION REQUESTS: Tel: 847-564-9290 Fax: 847-564-9453 Fullfillment Manager; P.O. Box 3588, Northbrook, IL 60065-3588 email: [email protected] ADVERTISING REQUESTS: see p. 72 For photocopy or reuse requests: 800-772-3350 or [email protected] For reprints: Wrights Media, 1-877-652-5295, [email protected] ACCESS INTELLIGENCE, LLC

DON PAZOUR
Chief Executive Officer

ROBERT PACIOREK
Senior Vice President, Chief Information Officer

ED PINEDO
Executive Vice President & Chief Financial Officer

SYLVIA SIERRA
Senior Vice President, Corporate Audience Development

MACY L. FECTO
Exec. Vice President, Human Resources & Administration

MICHAEL KRAUS
Vice President, Production and Manufacturing

HEATHER FARLEY
Divisional President, Access Intelligence

STEVE BARBER
Vice President, Financial Planning and Internal Audit

GERALD STASKO
Vice President/Corporate Controller 4 Choke Cherry Road, Second Floor Rockville, MD 20850 www.accessintel.com

ast month, we ran a letter from reader, Jason Makansi, commenting on our June story, Chemical Engineering Education Evolution (Chem. Eng., June 2012, pp. 2225), which highlighted, among other things, the need for a more-meaningful connection between academia and industry. Makansis letter was passionate in itself, expressing frustration at the slow pace of progress over the past 30 years or more. Equally passionate was the response that Makansis letter has prompted from the rest of our readership. While each opinion differs somewhat with regard to a solution, it is safe to say that most practicing engineers agree that the typical ChE graduate has always lacked some basic practical skills. In Makansis letter, he illustrates the central problem by explaining that when he graduated with his B.S.Ch.E., he did not know which way to turn a valve, or, for that matter, anything else about an actual process plant. Other readers, such as those whose letters appear on p. 6 of this issue, graduated with similar deficits in their practical know-how, with one admitting that as a newly graduated engineer from a respected university, I didnt even know what a pipe flange was. Of course, this is not the first time that the gap between academia and industry has been raised. Each one of you might have his or her own illustration to offer. I, myself, often lament that the main thing I recall from my process-control class is learning how to perform Laplace Transforms a skill I never had the opportunity to retrieve in practice and probably never will. The question is not whether graduates lack hands-on experience; the question is what should be done about it. For nearly 30 years, Makansis suggestion has been that engineering schools should offer two tracks one for students likely to continue through graduate school and one for students who would be seeking jobs in industry. Meanwhile, one reader, Roger E. Blanton, points out that adding any standalone practical-training courses would exacerbate the difficulty that most students find in completing their ChE degrees in four years. His suggestion is to make more use of summer internships. Another reader, James S. Bloss, essentially makes the argument that nothing should be done about it. In his opinion, the chemical process industries are far too broad to incorporate enough hands-on specifics to make a significant difference, and core lessons in discipline and problem solving can go much farther. In my opinion, all three readers make good points. Problem solving is indeed a foundational skill that can be applied across industries and functions. And, like other readers, I often wonder whatever happened to co-ops?, which used to be a common route for a ChE student bound for industry. Like Makansi, though, I think that the education experience should be more tailored to the students professional goals. A twist on his two-track idea could be an applied-ChE degree option. Meanwhile, I, personally, do not object to longer, five-year programs. After all, I transferred from architecture, where that is an accepted state of affairs. Admittedly, however, not everyone embraces a five-year degree option. So, with that in mind, I think it is important to consider that practical learning does not necessarily mean more coursework. It is more of a distinction in the method of learning itself. If students had more opportunities to turn valves, see heat exchangers and work with actual process control systems, I would argue that absorption of the academic fundamentals would be more rapid in the first place. Rebekkah Marshall
CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Letters
Re: Education needs a reality check...
I would like to pass on a few comments on Jason Makansis letter titled Education needs a reality check, which appeared in the August 2012 edition (p. 6). I too, like Jason, began my now 36-year career not knowing which way to turn a valve but being fully trained in transport phenomena. Did my university fail me? No. My universitys ChE program (B.S.Ch.E. 1976, University of Akron) provided a very essential engineering skill-set: discipline and problem solving. Sure, I would like to see new hires have more practical knowledge, but the engineering field is so broad that I think it is difficult for any university to meet the need of every industry. In my field, power generation, we utilize engineers who excel at transport phenomena and finite element analysis (FEA), as well as engineers who excel in skills developed through the sweat of their brow, such as welding, machining or equipment repair. The common trait I observe is that successful engineers have the knack, a curiosity about how things work and how they can be improved. This is a teachable skill. I know. I was able to teach it to my son, a young electrical engineer. It constantly amazes me how his mind never stops working, investigating and inventing. This is the skill engineering programs need to focus on. James S. Bloss, P.E., Sr. Principal Engineer The Babcock and Wilcox Co., Barberton, Ohio

...internships should ll the gap


I read with great interest Mr. Makansis letter in the August 2012 Chemical Engineering periodical. It struck a chord with me when I recalled that as a newly graduated engineer from a respected university, I didnt even know what a pipe flange was. However, I was fortunate enough to be hired by a world-class air-pollution control equipment manufacturer. There, I quickly learned and became an expert as I was sent out to start up newly installed systems. Im not saying this is ideal, but it is reality. Many students cannot complete an engineering curriculum in four years. Adding any practical training courses would exacerbate that goal. The solution may lie in summer intern jobs where students can gain practical insight into how their education can be applied, and learn about necessary topics not covered in the classroom, like how to turn a valve. In addition, it provides a company an opportunity to try out a potential employee and target those students that fit their organization at graduation. I believe that an engineering degree doesnt provide everything a graduate needs to know to function in our industry, but it is an indicator to an employer that the individual has the capacity to learn. If we work together with educators and provide opportunities to supplement the academic curriculum with real-life experiences in summer positions, we can all win. Roger E. Blanton, P.E., Business Development Manager John Zink Co., LLC,Tulsa, Okla.
Circle 24 on p. 72 or go to adlinks.che.com/40271-24 6 CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Over 50 years of experience


The Larox solid liquid separation equipment is now available from Outotec.

www.outotec.com

Need a new gear for your 1967 HDM Double Planetary Mixer? No problem.
Ross mixers and blenders are engineered to run trouble-free for decades. But if you ever need a replacement part, chances are we have it right here, ready to ship in 48 hours or less. We keep a multi-million dollar inventory of parts in stock from planetary gears to rotors, stators, seals and O-rings for your High Shear Mixer. So, when you need help to keep your production on track, you can count on us. Learn more about the value built into every Ross mixer and blender. Visit www.mixers.com. Or call 1-800-243-ROSS.

Jon Kerr Parts Manager Ross Employee Owner

Scan to learn more.


Free Tag Reader: http://gettag.mobi

Circle 28 on p. 72 or go to adlinks.che.com/40271-28

Bookshelf
Chemical Thermodynamics for Process Simulation. By Jrgen Gmehling, Brbel Kolbe, Michael Kleiber and Jrgen Rarey. Wiley & Sons Inc., 111 River Street, Hoboken, NJ 07030. Web: wiley.com. 2012. 760 pages. $135.00.

Reviewed by David Hill, Chemstations Inc., Houston

he authors of this text are leaders in chemical engineering thermodynamics. Based on their status, I recommended this book in a blog entry before even seeing a review copy and Im glad I did. The book is aimed at both students and professionals who work with process simulators. It assumes a prior understanding of thermodynamics, and is a more advanced text that focuses on how complex thermodynamic situations affect the use and application of process simulation. Many aspects of applied thermodynamics are not explored in undergraduate courses. Users of process simulation are often left to learn this material on their own. Gmehlings book assembles many of these topics in one text, and supplies examples and sample problems. It is more approachable and extensive than the out-of-print

thermodynamics text by Stanley Walas (Phase Equilibria for Chemical Engineering, 1985). In the book, mathematics some quite complex is interspersed with clear explanations of what the mathematics indicates. This is helpful because many practitioners may require a refresher for the mathematics, and many students will not be aware of practical applications that the mathematics can explain. Effective explanations are provided for why there are different models for physical properties and vapor-liquid equilibria (VLE). Background on some of the models and equations is also discussed, as are the strengths and weaknesses of the methods. The explanations of why we have different types of models (activity methods and equations of state) for VLE are very helpful. Many topics that routinely confuse users of process simulators are discussed and explained. There is an excellent explanation on the often confusing concept of reference state of enthalpy. Modeling options for special systems, such as polymer, acetic-acid-water, or formaldehyde-water, are discussed. Both the theoretical basis and practical implications of azeotropes are also well explained, and the book includes one of the best available explanations of residue curve maps. The explanation on how simulators calculate heat of reaction is also very helpful.

NEED TECHNICAL SUPPORT


for your Hot Oil System?
TechTeam can Help Keep Your Hot Oil System Running!

IC NON-TOXDOUS R A NON-HAZ r Fluid


nsfe Heat Tra

Heat Transfer Fluids Filter Systems Cleaning Trouble Shooting


Call Today!

Design Training Start-Up Operations

1-800-225-7440
www.MultiTherm.com
Circle 22 on p. 72 or go to adlinks.che.com/40271-22 8
CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Although English is not the first language for the authors, the text is generally easy to read, despite an occasional clumsy phrase. The texts authors are involved with DDBST products (Dortmund Data Bank, the Dechema database), and contributed heavily to the development of the PSRK (Predictive Soave-Redlich-Kwong) and VolumeTranslated Peng-Robinson (VTPR) models. I felt the book promoted these methods and tools too heavily. That being said, I am a strong proponent of the PSRK VLE model and would agree that these tools and methods are powerful. Sample Mathcad files are available, but it would have been helpful to see the examples in Matlab also. This text explains many of the concepts that my companys technical support group regularly explains to users of our process simulator, and we recommend this book to our customers. Guide to the Business of Chemistry. By the American Chemistry Council, 700 Second St. NE, Washington, D.C. 20002. Web: americanchemistry.com. 2012. e-book. $385.00. Guidelines for Engineering Design for Process Safety, 2nd ed. By the Center for Chemical Process Safety. John Wiley & Sons Inc. 111 River St., Hoboken, NJ 07030. Web: wiley.com. 2012. 440 pages. $125.00.

Practical Spray Technology: Fundamentals and Practice. By Charles Lipp. Lake Innovation LLC, P.O. Box 3596, Lake Jackson, TX 77566. Web: lakeinnovation. com. 2012. $385.00. Practical Thermocouple Thermometry, 2nd ed. By Thomas Kerlin and Mitchell Johnson. The International Society of Automation. 67 Alexander Drive, Research Triangle Park, NC 27709. Web: isa.org. 2012. 181 pages. $89.00. Colour Design: Theories and Applications. Edited by Janet Best. Woodhead Publishing Ltd. 80 High St., Cambridge, CB22 3HJ, UK. Web: woodhead-publishing.com. 2012. 672 pages. $315.00. CRC Handbook of Chemistry and Physics, 93rd ed. Edited by William Haynes. CRC Press, part of Taylor & Francis Group, 6000 NW Broken Sound Parkway, Suite 300, Boca Raton, FL 33487. Web: crcpress.com. 2012. 2,664 pages. $169.95. Scott Jenkins

Think Environmental Protection. Think Cashco Vapor Control.


The full line of Vapor Control System from Valve Concepts has established the industry standard for engineered quality and in-ield adaptability. The engineered modular design enables us to reduce capital outlay costs from 33% to 66% depending on the model. Our vents are engineered to be fully modular in design so they can be converted in design and function in the ield. Any one of our vents can be changed to a pipe away, spring loaded, or even a pilot operated vent without having to buy a whole new unit. Now thats innovation that VCI customers proit from.

www.cashco com
Innovative Solutions

Model 3100/4100

Model 3400/4400

Model 5200

Cashco, Inc. P.O. Box 6, Ellsworth, KS 67439-0006 Ph. (785) 472-4461, Fax: (785) 472-3539

Circle 8 on p. 72 or go to adlinks.che.com/40271-08
CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Process Insight:
The removal of CO2 by liquid absorbents is widely implemented in the ield of gas processing, chemical production, and coal gasiication. Many power plants are looking at post-combustion CO2 recovery to meet environmental regulations and to produce CO2 for enhanced oil recovery applications. The igure below illustrates actual data of fuel consumption in 2005 and an estimate of energy demand for various fuels from 2010 to 2030. The world energy demand will likely increase at rates of 1015% every 10 years. This increase could raise the CO2 emissions by about 50% by 2030 as compared with the current level of CO2 emissions. The industrial countries (North America, Western Europe and OECD Paciic) contribute to this jump in emissions by 70% compared to the rest of the world, and more than 60% of these emissions will come from power generation and industrial sectors.

Optimizing CO2 Capture, Dehydration and Compression Facilities


and constraints. Using the ProMax process simulation software from Bryan Research & Engineering, CO2 capture units can be designed and optimized for the required CO2 recovery using a variety of amine solvents. The following igure represents a simpliied process low diagram for the proposed CO2 Capture Plant. The table below presents the main indings for CO2 capture from the coal ired power plant and the NGCC power plant, each designed to produce about 3307 ton per day (3,000 TPD metric). To produce the same capacity of CO2, only one train with smaller column diameters is required in the case of the coal power plant and two trains with larger column diameters are required in the NGCC Power Plant case. This is mainly

Despite the strong recommendations from certain governments, there are very few actual investments in CO2 capture facilities geared toward reducing greenhouse gas emissions mainly because of the high cost of CO2 recovery from lue gas. CO2 capture costs can be minimized, however, by designing an energy eficient gas absorption process. Based on the indings of recent conceptual engineering studies, HTC Purenergy estimated the production cost to be US$ 49/ton CO2 (US$ 54/ tonne CO2) for 90% CO2 recovery of 4 mole% CO2 content in the lue gas of NGCC power plants. A separate study showed the cost for 90% CO2 recovery of 12 mole% CO2 from a coal ired power plant to be US$ 30/ton CO2 (US$ 33/tonne CO2). The cost of CO2 recovery from coal power plant lue gas is substantially less than that of NGCC power plant lue gas due to the higher CO2 content in the feed. The energy eficiency of a CO2 capture plant depends primarily on the performance of the solvent and optimization of the plant. In traditional lue gas plant designs, MEA was the primary solvent and was limited to 20 wt% to minimize equipment corrosion. Recent developments in controlling corrosion and degradation has allowed an increase in the solvent concentration to about 30 wt% thus decreasing the required circulation and subsequent steam demand. A recent DOE study shows the steam consumption for an existing CO2 plant using 18 wt% MEA (Kerr McGee Process) is 3.45 lb of steam per lb of CO2 for amine regeneration. A modern process that uses 30 wt% MEA is expected to use 1.67 lb of steam per lb of CO2 for amine regeneration. The HTC formulated solvent is a proprietary blend of amines and has a lower steam usage than the conventional MEA solvent. Based on the material and energy balances for the plant designed in the recent study, the reboiler steam consumption is estimated at about 1.47 lb steam/lb CO2 using the proposed formulated solvent without implementing any split low conigurations. This is much less than the reported steam usage for the MEA solvent. The design of a facility to capture 90% of the CO2 from the lue gas of a coal ired power plant is based on the speciied lue gas conditions, CO2 product speciications,

due to processing a larger lue gas with lower CO2 content in the NGCC power plant. Consequently, a substantial reduction in the capital and production cost was reported for the coal ired power plant CO2 recovery facility.

For more information about this study, see the full article at www.bre.com/support/technical-articles/ gas-treating.aspx.

P M

O G

C US

Circle 5 on p. 72 or go to adlinks.che.com/40271-05

Edited by Gerald Ondrey

September 2012
CO shift PSA Fuel gas H2

A high-temperature F-T process demonstrated in China

ynfuels China Technology Co. (Beijing; www.synfuelschina.com.cn) says it has developed a high-temperature slurry Fischer-Tropsch (F-T) process (flowsheet) that produces mainly clean diesel, naphtha and liquefied petroleum gas (LPG) products, with unique features including: high productivity of proprietary catalyst; efficient recovery of reaction heat by producing 2.53.0-MPa(g) steam, which can be used to generate electricity; a uniform temperature distribution in the slurry bed; and easy integration with different synthesis-gas- (syngas) production technologies. To design the F-T catalyst, the company first used quantum chemistry to calculate the molecular energy levels of different crystal faces, and then achieved the desired catalyst structure by strictly controlling the preparation conditions. This approach resulted in high productivity of the catalyst. The companys technology has been successfully applied in the Yitai 160,000-ton/ yr, and the Luan 160,000-ton/yr demonstration coal-to-liquids (CTL) plants, located at Ordos City in the Inner Mongolia Autonomous Region. Features of the Yitai plant include: a uniform temperature distribution across the 5.3-m slurry-bed reactor; the ability to easily separate the catalyst from the wax, and replace it online to ensure the continuous and stable operation of the plant; and the utilization of the F-T heat of reaction by pro-

Tail gas convention Boiler Steam ASU O2 Coal gasification Coal Water Crude syngas Purification CO+H2 Sulfer recovery CO2 removal Tail gas F-T synthesis Low temp oil absorp

Sulfer

LPG

H2

Product upgrading Steam

LPG naphtha diesel

Coal-water slurry prep.

CO2 F-T reaction water treatment Generator Electricty

ducing 3-MPa byproduct steam, which can be used to generate electricity for the power supply of the CTL plant itself. The Luan plants features include: nitrogen from the air-separation unit and hydrogen from the pressure-swing-adsorption (PSA) unit are used for the synthesis of ammonia, which is used to produce urea with the high-purity CO2 from the purification and F-T synthesis units; the fuel gas from the PSA unit is used for integrated gasification combined cycle, improving the total heat efficiency of the plant. Based on its experience with the demonstration plants, Synfuels China is now working on a few large-scale CTL projects.

Artificial photosynthesis
Scientists at Panasonic Corp. (Osaka, Japan; www.pana sonic.com) have developed an arti cial photosynthesis system that utilizes sunlight to convert CO2 to organic materials (mainly formic acid) at what is said to be the highest efficiency yet achieved (0.2%). The efciency level is comparable to that of plants. The keys to the Panasonic system are a nitride semiconductor, which is used as a photo-electrode for the reduction of CO2, and a metal catalyst to accelerate the reaction and increase selectivity. The research was presented at the International Conference on the Conversion and Storage of Solar Energy in July. The company hopes to use the development in a system to capture and converte waste CO2 from incinerators, power plants and other industrial processes.

A commercial move toward algae farming for CO2 recovery


dvanced Algal Technologies (Sydney, Australia; www.advancedalgal.com) has signed a $100-million deal with Fuzhou Xiangli Enterprise Management Consulting (Fuzhou, China) an LED-lighting manufacturer for a license to build 500 algal-farmingconveyor modular units per year. These units will be used to reduce carbon dioxide emissions in manufacturing plants in China. Traditionally, algae have been grown either in open ponds, or in bioreactors (see, for example, Chem. Eng, September 2008, pp. 2225). Both entail serious limitations: open ponds are subject to external conditions such as weather, pollutants and wildlife; bioreactors may require expensive sun tracking equipment and involve problems in harvesting the algae. Meanwhile, bioreactors still rely on contact of the gas bubbles
Note: For more information, circle the 3-digit number on p. 72, or use the website designation.

in the water to dissolve the CO2. In the patented system, developed by Advanced Algal Technologies, the algae are grown on a fabric inside an insulated building, within a precisely controlled environment. The algae can grow to a density of 100 g/m2 per day. The algae are in constant contact with the correct levels of CO2 in the atmosphere of the growing structure, and the use of a wet mat technology provides a high molecular transfer rate of CO2 in solution. The company said the system allows maximum algae yield. For example, a 3,000-m2 warehouse fitted with the system can produce more than 200 ton/d of algae or more than 50,000 L of algal oil and 150 tons of high-protein animal feedstock. Such a facility would consume more than 130,000 ton/yr of CO2.

Ion exchange
The RecoPur system from EcoTec Inc. (Pickering, Ont.; www. eco-tec.com) improves the performance of the ion exchange process for treating produced water at oil drilling locations. The system features an ionexchange resin with ner particles than conventional resins, and resin beds that are

(Continues on p. 12)
11

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

C HEMENTATO R

(Continued from p. 11)


shorter, allowing higher lowrates in a more compact footprint. RecoPur is designed to efficiently remove calcium and magnesium from produced water at oil drilling sites so that the high-salinity water can be used as feed water for once-through steam generators (OTSG) in steam-assisted gravity drainage (SAGD), and other enhanced oil-recovery techniques. The RecoPur system consists of a strong-acid- and weak-acid-cation resin bed that can reduce total hardness from thousands of ppm to less than 0.1 ppm. The ion-exchange system also signiicantly reduces the use of salt for regeneration of the resin.

A step toward the production of fuel for nuclear fusion


asaru Nakamichi, leader of the Blanket Technology Group, Naka Fusion Institute, Japan Atomic Energy Agency (JAEA, Ibaraki, Japan; www.naka.jaea.go.jp) has developed a new fabrication technology that enables the mass-production of beryllium intermetallic compounds (beryllides), which are advanced, efficient neutron multipliers that could be used for nuclear fusion reactors. JEAE is said to be the first to fabricate beryllides with 1-mm dia., and it expects the newly developed technology to be a big step toward establishing fuel-production technology for the nuclear-fusion demonstration (DEMO) reactor. At temperatures higher than 600C, JAEA has found that the beryllide Be12Ti expands by only 3% compared to 50% expansion by Be itself. Also, hydrogen generation from the reaction of steam at high temperatures a potential hazard in fusion reactors is 1,000 times higher with Be compared to Be12Ti. JAEA has optimized the fabrication method at the DEMO Design and R&D Co-

ordination Center of International Fusion Energy Reactor Center (IFERC; Aomori; www.naka.jaea.go.jp), where it has produced ductile and easy-worked beryllides rod, using beryllides raw powders with surfaces cleaned by a plasma sintering method. In the past, such materials prepared by alternative methods have been too fragile and unworkable to make powders. By using the beryllides rod as the electrode in a rotating electrode process, researchers have fabricated the worlds first beryllides fine particles with 1-mm dia. This achievement will contribute to the fuel production test at the International Thermonuclear Experimental Reactor (ITER; naka-www.jaea.go.jp), and also toward establishing a fuel-production technology for the nuclear fusion DEMO reactor. The scientists also believe that this technology could be applied for the fabrication of aluminum-based alloys that are lightweight, and heat and wear resistant, for use as mechanical parts in high-performance automobile engines.

Sans organomercury
The Dow Chemical Company (Dow; Midland, Mich.; www.dow. com) has voluntarily completed a program to replace mercurybased catalysts used in a product portfolio acquired from another company. The results

(Continues on p. 14)

Circle 23 on p. 72 or go to adlinks.che.com/40271-23

Partner with the Best

Sterile ice fog improves control of freeze-drying

Circle 29 on p. 72 or go to adlinks.che.com/40271-29
A01120EN

inde Gases (Murray Hill, N.J.; www.linde-gases.com) has developed a novel cryogenic technology that promotes uniformity in the formation of ice crystals during freezedrying (lyophilization) processes for proteins, vaccines and other injectable pharmaceutical products. Lyophilization involves freezing a solution of the product, then reducing the surrounding pressure to allow the water to sublimate. Because of the high purity of the water and clean production environments used in pharmaceutical products, there is a lack of nucleation points for water to begin freezing, explains Prerona Chakravarty, Manager of Lindes project, known as VeriSeq Nucleation. The solutions become supercooled, which makes controlling the formation of ice crystals difficult, she adds. This lack of control lengthens operating cycles and reduces product yields. The Linde technology uses a proprietary mixing technique to blend liquid nitrogen with ultrapure water to create a mist of fine, sterile ice crystals. The ice fog rapidly spreads throughout the lyophilizing chamber and causes all vials to freeze at the same time and at the desired temperature. Controlling the temperature at which a vial freezes the ice nucleation temperature produces the preferred ice structure within the product, which reduces processing time and minimizes product damage. This can be seen in the top image, which shows the magnified pore structure of a freeze-dried product subjected to VeriSeq Nucleation. The pores are larger and more regular, which leads to improved drying properties. The image on the bottom shows the pore structure of a freeze-dried product without any nucleation control. Lindes VeriSeq Nucleation technology can be retrofitted onto existing dryers, as well as incorporated into new installations, Chakravarty says, and initial customer feedback from early demonstrations of the technology, which was unveiled last June at the Achema 2012 tradeshow, has been positive.

With over 50 independent subsidiaries and more than 220 engineering and sales ofces spread across the world, SAMSON ensures the safety and environmental compatibility of your plants on any continent. To offer the full range of high-quality control equipment used in industrial processes, SAMSON has brought together highly specialized companies to form the SAMSON GROUP.

SAMSON AG MESS- UND REGELTECHNIK Weismllerstrae 3 60314 Frankfurt am Main Germany Phone: +49 69 4009-0 Fax: +49 69 4009-1507 E-mail: [email protected] www.samson.de SAMSON GROUP www.samsongroup.net

C HEMENTATO R
Supply

This new pump system improves efficiency for desalination operations


new hydraulically driven, positive-displacement-pump system can lower the energy requirements for pumping water by 10% in large seawater reverse osmosis (SWRO) desalination plants, where electricity typically represents the largest cost. Recently launched by GE Water & Power (www.ge-energy.com) at the 2012 International Water Week in Singapore, the IPER (integrated pump and energy recovery) system is designed for plants with greater than 1,000-m3/d capacity, where crank-driven positive displacement pumps are not practical because the crankshaft lengths become prohibitively large. Improvements to the conventional centrifugal pumps used for higher capacity SWRO plants have been able to deliver only incremental energy savings. In the IPER system (diagram), the crankshaft is eliminated, and the piston is instead moved by a unique hydraulic-drive system that powers three double-acting pistons at much slower cycle speeds than traditional positive displacement pumps. The system

FSH

Feed FPH RO

Product water

Discharge CDH Patent pending Hydraulic drive

Concentrate FSH = Feed supply header FPH = Feed pressure header CPH = Concentrate pressure header CDH = Concentrate discharge header

(Continued from p. 12)


of the 18-mo program enabled Dow Formulated Systems to remove all organo-mercury catalysts from its polyurethane (PU) elastomer products prior to the E.U.s formal recommendation to phase out these catalysts, and ve years before such compliance is mandated. Dow launched its complete suite of re-engineered PU elastomer products earlier this year. This launch required eight different catalyst packages to replace just one that used a mercurycontaining catalyst. The new Hy-

consists of a hydraulic-pump-drive unit, a water-displacement cylinder, and a sophisticated control unit. GE Water & Power has installed the system in a GE owned-and-operated facility in the Caribbean, and is in discussions regarding future installations. The company is also developing larger IPER units, says Erik Hanson, systems product management leader for water and process technologies at GE Power & Water, including one with a capacity of 2,500 m3/d, anticipated for August 2013 and a 10,000-m3/d unit in the third quarter of 2014.

(Continues on p. 16)

One tough test. One clear winner. CALFLO AF.


TM

Results from Severe Oxidative Stability Test.

A specialty heat transfer uid competitor


No flow, remains completely stuck in tube.

A world leader in industrial lubricants


Flows, but severe build-up of deposits remains in tube.

CALFLO AF
Flows easily, stays cleaner longer.

CALFLO AF delivers longer fluid life and better equipment protection. And more savings to you.
We put CALFLO AF and leading competitors to the test in a challenging Severe Oxidative Stability Test and the results are clear. CALFLO AF provides better oxidative stability for longer fluid life and enhanced equipment protection. That means more savings in operations and maintenance costs. And less worry. Test CALFLO AF, or another product in our line of CALFLO heat transfer fluids, in your operation. And see the results for yourself.

Visit www.calflo.com for the clear facts.


Petro-Canada is a Suncor Energy business
TM

Trademark of Suncor Energy Inc. Used under licence.

Circle 25 on p. 72 or go to adlinks.che.com/40271-25 14
CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

C HEMENTATO R

Strain-hardening test method speeds HDPE pipe testing


test method developed by SABIC (Saudi Basic Industries Corp.; Riyadh, Saudi Arabia; www.sabic.com) scientists drastically reduces the time needed to evaluate slow-crack growth resistance in high-density polyethylene (HDPE) that is used in pressure pipes. The strain-hardening test method allows HDPE producers to speed product development and improve quality control by offering an alternative to traditional approaches for collecting data on the longterm slow-crack growth performance of pressure pipes. Traditional methods, such as the full-notch creep test (FNCT) involve subjecting material samples to constant stress, and crack-inducing liquid and measuring the time to failure, a process that can go on for months. The strainhardening test consists of a tensile test carried out at 80C in a few hours. When a polymer sample is highly stretched, it exhibits strain-hardening, a phenomenon that SABIC scientists have correlated with slow-crack growth in HDPE, so that the slope of the stress/strain curve at very high elongation rate the so-called strainhardening modulus can be used to predict its resistance to slow-crack growth. The beauty of the method is that it can be carried out with non-specialized equipment right in the plant, rather than having to send samples out for testing at special institutes, says Ralph Handstanger, SABIC technical marketing engineer. So far the fundamental connections between strainhardening and crack propagation have been worked out for the assessment and ranking of HDPE raw materials, Handstanger says. There is potential for the application of this approach to pipes and other areas, however.

This silicone coating keeps electrical insulators safe


acker Chemie AG (Munich, Germany; www.wacker. com) has commercialized a solvent-free coating for electrical insulators. Powersil 570 Plus is said to be the worlds first insulator coating based on a patented siliconein-water emulsion technology. Its viscosity displays a strong dependence on its shear rate, which makes it possible for spray applications. The one-component emulsion is applied by spraying and then it cures to form a water-repellent silicone coating. It adheres to ceramic and glass substrates, and passes the 1,000-h salt-fog test per IEC 62217. Porcelain and glass are commonly used to insulate overhead powerlines, but in coastal and industrial areas, salt deposits and dirt can impair the insulating properties, which can lead to electrical discharges or so-called pollution flashovers. To avoid such scenarios, insulators must be cleaned regularly. Silicone coatings maintain the electrical insulating properties, and their hydrophobicity prevents the formation of wet pollution layers. Thus, the typical flashover scenario wet film layer with an increased leakage current, dry band arcing, bridging or individual insulator sheds and finally the electrical flashover is impossible, says Wacker.

serv&care Comprehensive Protection for Your Investment


No matter in what markets you operate: serv&care maximizes the reliability of your plant with competent service solutions. Fast, reliable and backed up by the know-how of the original manufacturer.

GEA Westfalia Separator Group GmbH


Werner-Habig-Strae 1, 59302 Oelde, Germany Phone: +49 2522 77-0, Fax: +49 2522 77-2488 [email protected], www.gea.com
SE-420-1-002

engineering for a better world


Circle 14 on p. 72 or go to adlinks.che.com/40271-14

(Continued from p. 14)

C HEMENTATO R

This osmium-based catalyst is rendered nontoxic by polymer incarceration


rofessor Shu Kobayashi and his research group at The School of Science, University of Tokyo (Japan; www.chem.s.u-tokyo.ac.jp/ users/synorg/index_E.html) have developed an osmium-based catalyst for performing asymmetric syntheses of drug precursors. While showing the same catalytic performance of its predecessor a microencapsulated osmium oxide in a polymer the new catalyst system is not dissolved by solvents, which makes it possible to recover the catalyst for reuse. The new, so-called polymer-incarcerated osmium (PIOS) system is nontoxic, nonvolatile and stable for months in air. The catalyst is made by mixing OsO4 in a styrene-based polymer solution for 72 h. Hexane is then added, which causes the OsO4 to become microencapsulated by the polymer. After removing the solvent, the solids are heated to 110C, which crosslinks

perplast and Diprane products ensure that users can already be conident to have non-mercury catalysts that comply with future REACH requirements, says the company.

the polymer into a matrix in which the OsO4 is bound. The catalyst enables a one-step reaction process instead of the three or four steps required by conventional catalyst technologies. For example, the chemists demonstrated that the PIOS system catalyzes the asymmetric dihydroxylation of alkenes into the corresponding diols with high yields and high enantioselectivities. They also prepared 1-mol quantities of a key intermediate for camptothecin (an anticancer drug) with 97% yield with the catalyst. They also confirmed that osmium was not detected to be absorbed in the organs of PIOS-dosed mice in acute toxicity tests. The researchers are expecting that their achievement on immobilization and stabilization of a toxic system could be applied to other catalyst systems that show high activity but also suffer due to high toxicity.

Phenol recovery
Last month, Rhein Chemie Rheinau GmbH (Mannheim, Germany; rheinchemie.com) was awarded irst prize in this years Responsible Care competition held by the BadenWuerttemberg branch of the German Chemical Industry Assn. (VCI; Frankfurt am Main, Germany; www.vci.de) for a process to recover phenol from mixed wastewater streams generated in the manufacture of a plastics additive. The process removes phenol and recycles it back to the production process, thereby reducing the amount of phenol to be disposed of by around 150 metric tons per year.

Phosphorus recovery
Researchers from the Fraunhofer Institute for Interfacial Engineering and Biotechnology (IGB; Stuttgart, Germany; www.igb.fraunhofer.de) are developing a patented process for the recovery of struvite (magnesium-ammonium phosphate) from sewage sludge. The electrochemical process precipitates struvite (from a solution containing nitrogen and phosphorus) as crystals that can be directly used as a fertilizer, without the need for further processing. The process is now being tested in a mobile pilot plant, which features a 2-m tall electrolytic cell with a sacriicial magnesium anode and a metallic cathode. Water is split into OH at the cathode, and oxidation takes place at the anode to form Mg+2 ions, which migrate through the water and react with PO43 and NH4+ to form struvite. So far, the required power for the process has never exceeded 70 W-h/m3 for all types of wastewater tested, and the researchers have demonstrated that the phosphorous concentration is reduced by 99.7% to less than 2 mg/L, which is lower than the maximum allowable concentration permitted by the German Waste Water Ordinance (AbwV).

A move toward bio-based malic acid . . .


ovozymes A/S (Copenhagen, Denmark; www.novozymes.com) has developed a strain of metabolically engineered Aspergillus oryzae fungus that is capable of producing the four-carbon, dicarboxylic acid compound malic acid. The chemical building block malic acid is used as a flavor enhancer in the food industry, and can be converted into 1,4-butanediol (BDO), which serves as a precursor to many other chemical derivatives used in resins and polymers. Developed

in partnership with Archer Daniels Midland Co. (ADM; Decatur, Ill.; www.adm.com), the robust fungus strain generates high yields of malic acid and has the potential to achieve production economics similar to petroleumderived malic acid, says Novozymes vice president Rasmus von Gottberg. Novozymes is looking to out-license the fungus strain and associated technology to partners who would commercialize the bio-based malic acid and its derivatives.

. . . and acrylic acid . . .


eanwhile, BASF SE (Ludwigshafen, Germany; www.basf.com), Cargill (Minneapolis, Minn.; www.cargill.com) and Novozymes signed a joint R&D agreement to develop an industrial biotechnology-based production process for acrylic acid. Since 2008, Novozymes and Cargill have collaborated to develop microorganisms that con-

vert renewable feedstock into 3-hydroxypropionic acid (3-HP), which is a possible precursor to acrylic acid. BASF has now joined forces to develop a process to convert 3-HP into acrylic acid. BASF plans to first use the bio-based acrylic acid to manufacture superabsorbent polymers, which are used in diapers and other hygiene products.

. . . and butadiene
lso last month, Invista (Wichita, Kan.; www.invista.com) and LanzaTech (Roselle, Ill.; www.lanzatech.com) signed a joint development agreement focused on bio-based butadiene. According to the agreement, Invista and LanzaTech will collaborate on projects to develop one- and two-step technologies to convert carbon monoxide into butadiene.
16

Initial commercialization is expected in 2016. The collaboration will initially focus on the production of butadiene in a twostep process from LanzaTech CO-derived 2,3-butanediol (2,3 BDO). A direct singlestep process will also be developed to produce butadiene directly through a process of gas fermentation.

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

CHEMICAL PRODUCTION SEES DECLINE

Newsbriefs

Cheaper chemicals from algae, farms & forest may be possible, report says

he bio-based materials and chemicals industry needs to tap newer, nonfood sources of biomass and cellulosic material and raise volumes of feedstock before it can emerge as an economically viable alternative to petroleumbased products, according to a Lux Research (Boston, Mass.; www. luxresearchinc.com) report. Currently, the high cost of capital and operations limit bio-based materials and chemicals to a few facilities located where corn and sugarcane are plentiful and inexpensive. Bio-based materials and chemicals manufacturers need syngas [synthesis gas] and sugar to fuel their growth. Gasification and enzymatic hydrolysis are key technologies for securing vast amounts, says Mark Bunger, research director and lead author of the report, Pruning the Cost of Bio-Based Materials and Chemicals. Lux Research analysts studied cost drivers in gasification, enzymatic hydrolysis of cellulose and algae cultivation to find opportunities where new technologies can turn them to profit. Among their findings:

A lgae remains a costintensive loser. In Lux Researchs model, algae cultivation yields a 48% loss, calling into question its long-term prospects. The problem lies in the high capital costs for growing algae at industrial scale S yngas fermentation has great new product potential. The many products of syngas fermentation proven at laboratory scale, or larger, include ethanol, butanol, acetic acid, butyric acid, 2,3-butanediol and methane. Leading startups in this domain include ZeaChem, which is collaborating with Procter & Gamble, and LanzaTech T here is hope for cellulosic biomass, but costs need to fall further. Enzymatic hydrolysis is being commercialized at new facilities like GraalBios plant in Brazil, using the latest enzymes from Novozymes and DSM. However, many parts of the process need to improve, including harvesting and collecting biomass, which adds $15/ton, or $0.21/gal, in costs

verall production of chemicals in the U.S. fell by 0.1% to 86.6% of its 2007 level during July, but the overall decline masked gains in specialty and bulk chemicals, according to data from the U.S. Federal Reserve Board that was analyzed in the August 17 Weekly Chemistry and Economic Report from the American Chemistry Council (ACC; Washington, D.C.; www. americanchemistry.com). U.S. specialty chemical production was up 0.4% in July, said the report, while basic chemical production gained 0.2%. Production fell in agricultural chemicals and consumer products.

EPA identies substitutes for toxic ame-retardant chemical


n an effort to identify possible substitutes for a toxic flame-retardant chemical, known as decabromodiphenyl ether (decaBDE), the U.S. Environmental Protection Agency (EPA; Washington, D.C.; www.epa.gov) has released a draft report on alternatives. This assessment, developed under EPAs Design for the Environment (DfE) program, profiles the environmental and human health hazards on 30 alternatives to

decaBDE, which will be phased out of production by December 2013. DecaBDE is a common flame retardant used in electronics, vehicles and building materials that can bio-accumulate in humans and animals. The technical assessment can help manufacturers identify alternatives to decaBDE. This draft report is the latest in a series of actions the agency is taking to address flame retardants made with bromine.

CSB deploys to re and explosion at Chevron renery


seven-member investigative team from the U.S. Chemical Safety Board (CSB; www.csb.gov) was deployed to the scene of an explosion and fire that occurred August 6 at the Chevron Refinery in Richmond, Calif. The team is headed by Donald Holmstrom, director of the CSBs Western Regional Office in Denver. Board member Mark Griffon accompa-

nied the team. According to company officials, the explosion and fire involved the release of vapor that found an ignition source. Four workers sustained minor injures. CSB chairman Rafael Moure-Eraso said, CSB investigations examine a wide range of safety issues such as effective process safety management and mechanical integrity.

Progress on a waste-to-fuels process reported at ACS meeting


process for converting municipal waste, algae, cornstalks and similar material to gasoline, diesel and jet fuel shows promise in larger plants, the developers reported at the National Meeting & Exposition of the American Chemical Society (ACS; Washington, D.C.;

www.acs.org), which took place in Philadelphia from August 1923. The technology, termed integrated hydropyrolysis and hydroconversion (IH2), was developed by the Gas Technology Institute (GTI; Des Plaines, Ill.; www.gastechnology.org). GTI scientist

Martin Linck anticipates multiple demonstrationscale facilities in operation by 2014. IH2 technology involves the use of internally generated hydrogen and a series of proprietary catalysts, which jump-start chemical reactions that otherwise would

happen slowly or not at all. Linck said it differs from other biofuel technologies in that it produces a finished, ready-to-use liquid hydrocarbon fuel, rather than crude intermediate substances or substances that contain oxygen, which must be processed further.
17

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Newsfront

CHEMICAL PLANT SECURITY: GATING MORE THAN THE PERIMETER


While fences and locks have been helping to secure the CPI for some time, the vulnerability of industrial control systems has only recently been demonstrated in ways that make everyone take notice. Cyber and physical security are now considered interdependent

Traklok

FIGURE 1. TrakLok integrated the physical security of a lock with a sophisticated system that monitors the security of cargo and instantaneously reports security breaches via cellular and satellite networks

t was clear at the recent Chemical Sector Security Summit (Baltimore, Md., July 31-Aug. 1) that awareness of and activity in security for the chemical process industries (CPI) are growing. The annual summit, now in its sixth year, was held at its largest venue ever and brought together about 650 participants from industry, academia and the government to network with other security professionals, share best practices and learn more about chemical security regulations. One of the strong messages from this summit, as well as from additional sources, is that more attention than ever before is being given to cybersecurity of industrial control systems. In fact, in her introductory comments at the summit Suzanne Spaulding, deputy undersecretary for the National Programs and Protection Directorate (NPPD) for the U.S. Dept. of Homeland Security (DHS; Washington, D.C.; www.dhs.gov) emphasized

an increased awareness of the interdependence between cyber and physical security and said that the chemical sector has been a leader to bring together those two disciplines. Meanwhile, in his keynote address at the summit, undersecretary for the NPPD, Rand Beers, spoke of a new appreciation of owners and operators across all sectors, including the chemical sector, for the need for cybersecurity. He said that in the larger picture, security requires teamwork across the government, private sector and the public. That type of teamwork was evident in the mix of participants at the summit. Evidence is also seen in a number of working groups that are collaborative efforts to reduce the risks to industrial control systems. A good example of this is the Industrial Control Systems Joint Working Group (ICSJWG; www.us-cert.gov/control_systems/icsjwg/).

CFATS
The CPI are considered part of the critical infrastructure in the U.S., and as such are regulated by the DHS under the Chemical Facility Anti-Terrorism Standards (CFATS; for details on CFATS see Chemical Plant Security, Chem. Eng., pp. 2123, September 2009). While CFATS continues to be a driver for much of the heightened activity in security, the program itself has recently been confronted by serious challenges. Last year at this time, with strong support in both the House and the Senate, CFATS was poised to be reauthorized by Congress for multiple years (as opposed to the annual reauthorization it had been receiving). However, an internal assessment of the CFATS program in the last months of 2011 brought to light some serious concerns about the management and implementation of the program. A multi-year reauthorization now seems to be unlikely in the foreseeable fu-

18

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

DUPR LOGISTICS, LLC / 201 Energy Parkway Suite 500 / Lafayette, LA 70508 For more information, call 855-686-5478 or email [email protected] www.duprelogistics.com

Circle 11 on p. 72 or go to adlinks.che.com/40271-11

Newsfront
ture. While authorization inspections have resumed as of July 2012, the program is currently facing the possibility of drastic funding cuts. During a Congressional Perspectives panel at the Security Summit, Monica Sanders, council for the House Committee on Homeland Security, shed some light on the CFATS situation. She explained that with a new program like CFATS, you want to have one-year authorizations until the program is mature, at which time it is extended for multiple years. Congress thought that CFATS was at that point, but the late 2011 memo was a game changer, she said, and heavy Congressional oversight is still needed on the CFATS program. The panel members, which also included Chris Schepis, senior professional staff member for the House Committee on Homeland Security; and Jerry Couri, senior professional staff member for the House Committee on Energy and Commerce, seemed to agree that they expected CFATS would face a budget cut. The panel also commented, however, that Congress wants to see CFATS succeed as the kind of program envisioned in 2006 when it was first authorized. While CFATS has been a driver for much of the heightened activity in security over the past few years, the goal of securing the CPI is not dependent on the standard. As Lawrence Sloan, president and CEO of the Society of Chemical Manufacturers & Affiliates (SOCMA; Washington, D.C.; www. socma.com) said in his opening remarks at the summit the reason we meet here is not merely because of the presence of a regulation, but because of a need for mutual collaboration ... industrys commitment to securing its most hazardous chemical products is stronger than ever, as evidenced by the overwhelming presence of so many attendees here today from the private sector. Others who are here who may not fall under CFATS or the Coast Guards MTSA [Maritime Transportation Security Act] program are also here to learn because, whether you are regulated or not, securing your assets and the communities in which you operate makes good business sense.

Thermal Processing Solutions for High Quality Products. Product uniformity, efciency, durability. Bhler AeroDryTM conveyor and uid bed dryers provide these critical elements to ne chemical and polymer processors around the world.

Buhler Aeroglide, 100 Aeroglide Drive, Cary NC 27511 USA, Tel +1 919 851 2000, Fax +1 919 851 6029 [email protected], www.aeroglide.com/chemicals

Physical security
Perimeter security is the first line of defense, says Ryan Loughin, director of Petrochemical & Energy Solutions at Tyco Integrated Security (TycoIS; Boca Raton, Fla.; www.tycois.com), and Tyco Integrated Security offers many solutions including advanced fiber-based technology, thermal imaging/infrared, analytics software and remote video products that help satisfy the CFATS Risk-Based Performance Standards. Indeed, most of CFATS addresses the critical need to physically secure chemical plants, with one of the major goals being to prevent theft and diversion. Diversion is a form of misappro-

Innovations for a better world.

Circle 6 on p. 72 or go to adlinks.che.com/40271-06 20
CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

priation, and refers to the acquisition of a material by means of deception, by someone who should not possess the material. While numerous forms of protection to avoid theft and diversion are employed at CPI sites, Tom Mann, CEO of TrakLok Corp. (Knoxville, Tenn.; www.traklok.com) sees a vulnerability during transportation. Manufacturers of high-value and high-risk products have enormous security at their facilities, says Mann, However, when they ship product, they have had no other options than a padlock and a tracking device. Manns company, TrakLok, has introduced a new truck and container security device (Figure 1) that combines physical security with realtime global monitoring and notification. The lock integrates the physical security of a lock with a sophisticated system that monitors the security of cargo and instantaneously reports security breaches via cellular and satellite networks. TrakLok also offers a geofencing capability prohibiting the lock from opening if it is outside a prescribed area.

to very credible-looking emails, often seemingly from trusted sources. Clicking on the attachment unleashes the malware, which then opens the gates to the sender to access the computer system of the unsuspecting victim. While most of the spear-phishing to date has been directed at information gathering, which in itself is reason to

defend against it, the threat of being able to do more, such as take control of an industrial control system (ICS) is real and has been demonstrated. Most users of ICSs are now aware of the Stuxnet worm, which was a real game changer for ICS security in that it was highly sophisticated and deliberately targeted to attack a

Cybersecurity
Adversaries are becoming more stealth, said Lisa Kaiser, operations lead, CyberSecurity Implementation, ICS-CERT, Office of Cybersecurity and Communications for the DHS, at the 2012 Chemical Sector Security Summit. In addition to the advanced complexity of threats, Kaiser said that there has been more than a 400% increase in the number of reported cyberrelated incidents from 2010 to 2011. This statistic is from the Industrial Control Systems Cyber Emergency Response Team (ICS-CERT) Incidence Response Summary Report1, which shows that the number of reported and identified incidents impacting organizations that own and operate control systems associated with critical infrastructure rose from 41 in 2010 to 198 in 2011. The threats. Kaiser cited an increased use of so-called spear-phishing involving major U.S. corporations including oil-and-gas, and water companies. Spear-phishing is a technique where malware-containing files are attached
1. Available at http://www.us-cert.gov/control_ systems/pdf/ICS-CERT_Incident_Response_ Summary_Report_09_11.pdf

Gorman-Rupp industrial pump packages are designed and pre-assembled to make on-site installation as simple as possible. Our packages are built from proven components that have been engineered to maximize the efciency of the entire package.

Circle 16 on p. 72 or go to adlinks.che.com/40271-16
CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

21

Newsfront
control system (for more on Stuxnet, see Securing the CPI, Chem. Eng., pp. 1720, September 2010; and Cybersecurity for Chemical Engineers, Chem. Eng., pp. 4953, June 2011). New Stuxnet-like malware has since appeared, including Duqu, identified in October 2011 and Flame, identified more recently this year. Even if CPI control systems are not specifically targeted by this type of malware, the fact that Stuxnet was wildly successful opens the door to collateral damage, says Rick Kaun, business manager for the Industrial IT Solutions Group of Honeywell Process solutions (Phoenix, Ariz.; www. becybersecure.com). In addition to spear-phishing through social media like emails, Kaun says that the use of USB sticks and other devices with unknown content in work systems is also a big concern for ICS. Andrew Ginter, director of Industrial Security at Waterfall Security Solutions (Calgary, Alberta, Canada; www.waterfall-security.com) echoes the concerns about collateral damage saying, Thus far the intent [of the malware] is industrial espionage, but it is clear that they are capable of much more. Industrial practitioners should not feel secure because they cannot point to a specific incident of harmful control, says Ginter. He explains further that if someone who shouldnt have access to your control system does, that in itself is unacceptable. The ability for unauthorized remote control has been demonstrated and is a threat. Even without malicious intent, an uninformed hacker who has control can do damage. Security experts. The suppliers of ICSs and security systems for them are continuously working on their arsenals to help prevent against cybersecurity threats. Waterfalls Ginter says that one approach to address advanced threats is to use hardware-enforced one-directional communication (Figure 2) so that information can be shared out of the industrial control network to the business side, but no information can get back to the process control side. Oftentimes ICSs are connected to business networks to help track raw-material and product inventories, schedule mainte22

Protected operations network

Hardware-enforced one-way communications

External business network

TX gateway

RX gateway

Waterfall Security Solutions

FIGURE 2. Unidirectional communication prevents communication from the business network back to the process control network

nance and replacement part ordering and more. Advanced threats can, however, penetrate the firewalls that are used between the business and control systems. Unidirectional gateways are a hardware and software solution that permit the flow of information out of isolated networks, but not back into them. Another tool that has been used in business IT environments but is relatively new to automation control systems is whitelisting. Honeywells Kaun explains that whitelisting means that only predefined applications and processes are allowed on the ICS systems. It protects from unwanted intrusions by allowing only those applications and files that have been placed on an approved list, and everything else is blocked. Anti-virus (AV) solutions on the other hand, are referred to as blacklisting, since they operate differently by blocking what is already known to be bad, but otherwise allowing everything else. Honeywell now offers a fully certified application and whitelisting solution to help combat malware from attacking its Experion Process Knowledge System. The end users of large companies are asking us to implement more security, including AV, whitelisting, firewalls etc., says Graham Speake, principal systems architect for Yokogawa Corp. of Americas (Newnan, Ga.; www. yokogawa.com/us) IA Global Strategic Technology Marketing Center in Dallas, Tex. Some are also looking to have some or all of these services outsourced and managed by the vendor, he says. Notifications of patches for various systems from various vendors can be confusing for end users to coordinate and implement correctly. Part of this, says Speake, is due to the fact that there has not been a definition of

what to put into a patch. There is, however, an ISA99 (International Society of Automation; Research Triangle Park, N.C.; www.isa.org) working group that is addressing this need and preparing a draft standard for patch management in the ICS environment. Speake says that Yokogawa offers users a field service where they will come in and implement upgrades and patches on a regular basis (quarterly, for example). While not yet widespread, this service is particularly useful for small-to-medium size companies who may not have the resources to keep their systems up-to-date. As security measures become more complex, more support will likely be needed. No quick fixes. Security experts agree that the solutions to help thwart cybersecurity threats are not quick fixes. And, that while awareness of the vulnerabilities and threats is increasing, there is still a way to go. Looking forward, Yokogawas Speake says the drive for products and devices that have security designed and built into them will become more intense. It is easier for vendors to build security in than for end users to add it on afterwards. It is the vendors responsibility to enable this security, and then the end user must take responsibility for keeping these products up-to-date and provide or outsource the services needed to monitor the security devices. It [security] is a discipline much like safety and maintenance, emphasizes Honeywells Kaun. The day he drives up to a plant and sees a sign that reads So many days since a cybersecurity incident next to the sign that says So many days since a safety incident is when he will feel that we have reached a good level of awareness. Dorothy Lozowski

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

&
IN-DEPTH SHORT COURSES SOLUTION-BASED CASE STUDIES INNOVATIVE DISCUSSION GROUPS

SYMPOSIUM

28th

USERS SYMPOSIUM

George R. Brown Convention Center, Houston, Tx

HANDS-ON TUTORIALS PIONEERING LECTURES OUTSTANDING EXHIBIT FLOOR

Our Technical Sessions are the best value for your training dollar and are taught by leading industry experts!
Exhibits Open Free to the Public Tuesday & Wednesday 2:30 p.m. - 7:00 p.m. Thursday 9:30 a.m. - 12:00 p.m. For more information
Call 979.845.7417 or email at [email protected] Sponsored by: The Turbomachinery Laboratory Texas A&M University College Station
Circle 31 on p. 72 or go to adlinks.che.com/40271-31

http://turbolab.tamu.edu

Conval

Newsfront News Roundup Equipment

AN OPEN AND SHUT CASE


Improvements in valve technology allow processors to improve performance while reducing leaks

FIGURE 1. Clampseal bellows seal valves allow for zero emissions in applications where packed valves may not reliably contain light gases or hazardous uids

A NOD TO AUTOMATION
n addition to making leak-free, high performance valves, industry experts say actuation is growing considerably. I believe the increase in actuation is related to labor savings in that by automating the systems, users are able to see, from a remote monitoring station, whats going on with the valves whether theyre engaged, on or off, having issues and so on, says Dave Stewart, director of marketing with Hayward Flow Control (Clemmons, N.C.). In a vast refinery or chemical plant that is not automated, this involves a lot of time spent getting to valves in remote areas, but by automating them you save a lot of time. Actuators serve as a way to monitor the status of the valves in a facility and, as more plants and refineries are being updated, actuation is being added. GF Piping Systems Dave Vollaire agrees: Automation is on the rise and we see people moving away from manual systems and using positioners and more feedback devices that reveal the actual position of valves in a system.

hough times are changing, many of the traditional challenges associated with running a chemical processing plant remain the same. For years processors have been asking for leak-proof, high-performance valves, but it is only recently that valve manufacturers are employing new technologies, designs and materials that improve performance and reduce leaks.

Improved Cv values
Traditionally, processors running batches of chemicals or feeds used ball valves because they typically offered the best Cv [valve flow coefficient] values without pressure drop, says Dave Vollaire, product manager for valves and actuation with GF Piping Systems (Tustin, Calif.; www.piping. georgfischer.com) However, one of the drawbacks of ball valves occurs when the line goes dry or chemical is allowed to crystallize. This can jam up the ball valves and cause damage to stems and seats and lead to leakage. To combat this issue, GF Piping now offers a line of diaphragm valves, the Georg Fischer 5 Series manual and pneumatic diaphragm valves, which
24

feature a central union nut, unlike conventional valves that include four metal screws to hold the top assembly on the valve body. This non-corrosive connection is characterized by homogeneous temperature behavior, even surface pressure and a high-pressure rating. In addition, the flow geometry offers double the Cv values. Another way to increase Cv value while decreasing leaks is to replace ball valves with a newer technology. For example, GF Piping also offers a new-generation, cone check valve with a spherical shaped design that offers improved flow characteristics and leak-proof operating performance. The aerodynamic, sphericalshaped cone ensures tight closing and 100% leak-proof operation, says the company, while providing improved Cv values over standard ball-type check valves. An added bonus of this, says Vollaire, is that while most ball valves require about 10 diameters of straight

run pipe after a flow disturbance (like an elbow or pump), this model requires half that, which allows use in smaller areas. Users dont need as many straight runs, and this is a big benefit because typically, in a pipe run, its difficult to find anywhere that is clear and free of obstruction, he says.

Reduced leaks
In most situations in the chemical, petrochemical and petroleum-refining industries, leaks are to be avoided at any and all costs, which is what makes packing integrity so important, says Michael Hendrick, vice president of sales and marketing with Conval (Somers, Conn.; www.conval.com). We make heavy process-industry valves for refineries and large plants that are scrutinized by the Environmental Protection Agency, he says. So this is a big, big issue for our customers and for us. Conval started using graphite packings some time ago because the tem-

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

GF Piping Systems

put an outer valve, like a dummy valve that throttles and closes the valve inside that is carrying the chemical. This type of double containment is especially helpful for lines that carry chemicals overhead, but have the potential to leak, because the secondary pipe contains the chemical leak from falling down.

GFs Double-See (Figure 2) is used as a pressure-rated, double containment system and offers versatile installation options, assembled and tested fittings and a pipe cut-length guidance system that provides a simplified approach to installation. The valve-in-valve design allows full-containment-pressure ratings.

FIGURE 2. The Double-See vinyl piping system provides a pressure-rated double-containment system for transporting hazardous liquids

perature limitations of plastics and rubbers are more restrictive, so the new and improved graphite packings work better, last longer and resist pitting, making them more suitable for critical applications with temperatures over 500F. However, to provide even more leakproof capability, Conval developed the Clampseal Packing System (Figure 1), which puts compression on the packing in an effort to maximize packing life in the demanding high-pressure and high-temperature applications. The uniform, single-piece gland allows the graphite packing to be loaded uniformly with a one-piece gland, which eliminates the potential for stem damage from gland cocking, while the integral gland wrench provides immediate gland/packing adjustment capability. This feature makes it easier to adjust the packing and gives more uniform compression of the packing, which helps reduce leaks, says Hendrick. The Clampseal technology can be found on many of the companys valves, including the new zero-emissions bellows seal valves, which are suitable for applications where packed valves may not reliably contain light gases or hazardous system fluids, due to leakage in the stem/packing seal or stuffing box, wall/packing seal area. Also to prevent leaks of hazardous liquids, many facilities are double containing their valve and piping systems, says Vollaire. This means they run the main carrier line of chemical, and around that line there is a second pipe, Vollaire says. In our case, we
Circle 10 on p. 72 or go to adlinks.che.com/40271-10
CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

25

Red Valve

Equipment News Roundup


Asahi/America

MORE VALVE PRODUCTS


Wafer check valves for critical water applications
These 10- and 12-in. PVC wafer check valves (photo) are installed on the discharge side of pumps to prevent backflow flooding that could damage pump systems. The body, disc and stopper assembly are machined from solid PVC plate stock, which conforms to ASTM D1784 Cell Classification 12454A. This material offers chemical resistance. The valve is easily installed by slip fitting the valve between two mating flanges. The valve body automatically centers on the mating flanges, once the stud pack is installed. A directional flow arrow on the valve body indicates the upstream and downstream sides of the valve. The lack of bolt pattern allows one valve style to accommodate many mating flange

dimensions. Asahi/America, Inc., Malden, Mass. www.asahi-america.com

An inline check valve for backflow prevention


The CheckMates (photo) custom-engineered, all-rubber, uni-body design eliminates backflow, while the elastomer-fabric reinforced-design reduces maintenance. The valve offers low head loss and can open to a near-full pipe diameter to maximize the flow

capacity of the outfall. The valves are available in 472-in. sizes. Tideflex Technologies, a Division of Red Valve Co., Inc., Carnegie, Pa. www.tideflex.com

Hand valves and manifolds for instrumentation applications


Hand valves and two-, three- and fivevalve manifolds in carbon steel (photo, p. 27) provide a solution for natural gas

Circle 9 on p. 72 or go to adlinks.che.com/40271-09 26
CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Hayward Flow Control

Parker Hannifin

transmission lines, and other chemical process industries instrumentation applications that dont require the extreme performance of stainless steel. The products are pressure rated up to 6,000 psig (414 bar) to provide system flexibility when selecting process valves. Designed to work with a variety of fittings, the valves and manifolds feature an external adjustable gland that allows for full adjustment of the stem packing without removal of the valve from the system. Handles are color-coded to quickly and easily identify valve functions. Parker Hannifin Corp., Huntsville, Ala. www.parker.com

Glass-filled PP makes this valve more durable


The platinum GF-PP (glass-filled polypropylene) TB Series ball valves (photo) feature a full port design with true-union threaded or flanged end connections and reversible seats. The valves have a maximum pressure rating of 250 or 150 psi with threaded or flanged ends, and a maximum service temperature of 240F. The platinum GF-PP material provides high impact resistance and is suitable for more robust chemical services, abrasive applications and water distribution. Features include an adjustable seat retainer, double O-ring stems and easy

actuation. Options include handle lockouts, 2-in. square operating nut, stem extensions, pneumatic or electric actuation, manual limit switches and spring return handle. Hayward Flow Control, a Division of Hayward Industries, Clemmons, N.C. www.haywardflowcontrol.com

Improve safety and reliability with this ball valve


The KTM Unibody EB700 Series ball valve is designed and certified to meet the standards and service requirements of the petrochemical, chemical and oil-and-gas industries through improved pipeline integrity, performance and safety characteristics. The one-piece, cast body minimizes potential leak paths, making it safer and more environmentally friendly than split body designs. With dual bodyinsert seals and shaft seals, this valve

Circle 17 on p. 72 or go to adlinks.che.com/40271-17

Rotork Fluid Systems

Equipment News
provides sealing integrity, says the manufacturer. The valves feature a PTFE/PFA co-polymer E seat. The valves in sizes above DN25 (NPS 1) also provide an additional safety feature incorporating cavity self-relieving seats to relieve potential ball cavity over-pressure when the valve is in the closed position. Tyco Flow Control, Princeton, N.J. www.tycoflowcontrol.com

300F. The valve is available in castiron or stainless-steel construction with square or round flanges in sizes 614 in. W.M. Meyer & Sons, Inc., Libertyville, Ill. www.wmwmeyer.com

W.M. Meyer & Sons

This dust-duty valve creates a quality air seal


The Dust Duty Valve (DDV; photo) comes with a robust cast housing designed for greater capacity and is suitable for dust collection. It will service applications where a quality air seal is necessary in light-duty, non-abrasive applications under baghouse, cyclone and dust collections with a maximum pressure differential of 60 in. wc.. The maximum temperature is

Spring-return actuators for infrequently operated valves


The ManPower range of products (photo) reduces installation time and expense since no electrical-, hydraulic- or pneumatic-power supply is required. Suitable for a range of ball, butterfly and plug valves, the scotchyoke actuators are equipped with a compact, self-contained, manually operated hydraulic-power pack. A hydraulic hand pump on the power pack

is used to operate the actuator and compress the failsafe spring, holding the valve in the desired open or closed position until a failsafe signal is received, at which point the spring will immediately drive the valve to the safe position. Failsafe operation can be triggered by electrical signals, highor low-pressure pilots or fire sensors, enabling the successful fulfillment of many ESD (emergency shutdown) and pressure-related protection duties in the oil, gas, petrochemical and pipeline industries. Rotork Fluid Systems, U.K. www.rotork.com Joy LePree

MONITOR VISCOSITY SIMPLY


SENSE MIXER MOTOR HORSEPOWER WITH UNIVERSAL POWER CELL
EASY INSTALLATION Noholesintanksorpipes Awayfromsensitiveprocesses VERSATILE Onesizeadjuststomotors,from smallupto150hp Workson3phase, xedorvariable frequency,DCandsinglephasepower SENSITIVE 10timesmoresensitivethan justsensingamps CONVENIENT OUTPUTS Formeters,controllers,computers 4-20milliamps0-10volts

PROFILING A PROCESS
Powerchangesre ectviscositychanges Goodbatcheswill tthenormalpro lefor thatproduct
POWER DECREASE SHOWS BATCH IS DONE

24 22 20 18 16 14 12 10 8 6 4 2 0

POWER SENSOR

DRY MIX HIGH SPEED

ADD LIQUID LOW SPEED BEGIN HIGH SPEED MIX

MIXER MOTOR

BATCH 1

BATCH 2

BATCH 3

CALL NOW FOR YOUR FREE 30-DAY TRIAL 888-600-3247


WWW.LOADCONTROLS.COM
Circle 19 on p. 72 or go to adlinks.che.com/40271-19 28
CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Emerson Process Management

FOCUS ON

Flowmeters

McCrometer

Endress+Hauser

A owmeter designed for biogas The Proline Prosonic B200 ultrasonic flowmeter (photo) measures flowrate and methane content of wet biogas, landfill or digester gas, and other types of lowpressure, wet or contaminated gas. The company has optimized transit-time ultrasonic technology for biogas applications. The B200s body is made from 316L stainless steel and is suitable for wet, dirty or corrosive gases. The flowmeter is available with either an aluminum or stainless-steel transmitter housing. The instrument can also measure and display direct methane fraction as a function of sound velocity and temperature, without the need for other instruments. The B200 operates in temperatures of 32 to 176F and pressures up to 145 psi. The accuracy of its volume flow is 1.5% of the reading. Endress+Hauser Inc., Greenwood, Ind. www.us.endress.com A wide choice of power solutions for this owmeter The AquaProbe insertion electromagnetic flowmeter range (photo) now has an extended range of power source and transmitter options. The AquaProbe series is designed to be used with this companys WaterMaster and AquaMaster 3 transmitters, and can now be powered with main and battery power, as well as renewable power. The new, renewable power version can draw power from either solar or wind

ABB Measurement

Sierra Instruments

sources. The enhancements make it ideal for clean water applications, the company says. The unit also features intelligent installation technology that performs a selfconfiguration sequence automatically on initial installation. ABB Measurement Products, Warminster, Pa. www.abb.com/measurement
Minimize pressure drop with this mass ow device The SmartTrak 140 (photo) is a mass flow controller for high-performance mass-flow-control applications where minimal pressure drop is a key consideration for cost savings and efficiency. The SmartTrak 140 controls gas mass flow up to 500 standard L/min, with an ultralow pressure drop of 4.5 psid. This level is considerably lower than other available mass flow controllers, which typically offer pressure drop values of 25 psid, the company says. The SmartTrak 140 combines two of this companys existing technologies: its laminar-flow element, sensor and digital electronics, and its low-pressuredrop valve, which has a large flow coefficient. The SmartTrak 140 also offers the ability to set zero, span and full-scale for

ten different gases independently in the field. This company also manufacturers the Chlorine-Trak 760S mass flowmeter, which is specifically designed for costeffective flow measurement in chlorine injection processes found in wastewater treatment applications. Sierra Instruments, Monterey, Calif. www.sierrainstruments.com
This owmeter has a directmount conguration This companys Wafer Cone flowmeter (photo) now has a direct-mount configuration where the transmitter is directly
29

Note: For more information, circle the 3-digit number on p. 72, or use the website designation.

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

The entire shale drilling community will come together in one place to take part in the event focused on environmental, health, safety, and regulatory considerations faced by the industry.

November 14 - 15, 2012


MORIAL CONVENTION CENTER

NEW ORLEANS, LA
Get the answers to these questions from industry experts at Shale EnviroSafe and discover how the CPI is being affected by the rise in shale gas supplies
How is natural gas changing the CPI? What are the latest regulatory considerations? How are costs affecting feedstock? What chemicals are being provided to the unconventional oil & gas industry for fracking?

For a complete conference agenda and list of exhibitors, visit www.ShaleEnviroSafe.com


CO-LOCATED WITH:
22
ND

Organized by:
3rd Annual

ANNUAL
7 TH ANNUAL

Deepwater
PREVENTION & RESPONSE

Focus

Flexim Americas

mounted, eliminating impulse lines. Eliminating impulse lines with the direct mount lowers installation costs, and reduces potential leak points by 50%, the company says. Simple plug-and-play mounting ensures the meter is installed correctly the first time. The advanced Wafer Cone flowmeter is ideal for gas or liquid service in line sizes from 1 to 6 in. The meters flange-less design makes installation fast and easy, while the interchangeable cone accommodates changing flow conditions without the need for recalibration, because cones can be removed and replaced with a cone at a different beta ratio. McCrometer, Hemet, Calif. www.mcrometer.com
DP owmeters that take advantage of the latest HART revision Rosemount Model 3051 pressure transmitter products (photo, p. 29), capable of measuring flow with differential pressure (DP), have been enhanced to take advantage of the latest revisions to the HART communication protocol (HART 7). In addition, the companys range of DP flow and level instruments now feature Power Advisory Diagnostics, a predictive diagnostic tool that allows users to identify electrical loop issues at the instrument or anywhere in the loop before they cause a loss of measurement. Examples of these issues include water or corrosion in the terminal block or junction boxes, wiring problems or a failing power supply. Emerson Process Management, Chanhassan, Minn. www.emersonprocess.com Handle severe duty with this owmeter The 3600 Series Digital Mass Flow instruments (photo) are designed specifically for severe industrial environments.
31

Parker Hannifin

Series 3600 devices are suitable for food and beverage, biotechnology and pharmaceutical and chemical processing applications that require frequent washdown, as well as chemical, petrochemical and industrial process applications where hazardous location certification is required. These stainless-steel flowmeters have digital control electronics that provide unparalleled accuracy, repeatability and control stablilty, as well as watertight construction that meets IP66 guidelines. Parker Hannifin, Hatfield, Pa. www.parker.com
Use this portable owmeter for hazardous areas The Fluxus F608 and G608 portable flowmeters (photo) are specifically engineered for use in hazardous areas. The flowmeter models, which can be used for liquids and gases, have been approved by FM International for use in Class I, Div. II areas. The F608 and the G608 are based on this companys widely used F601 and G601 models. The carbon-fiber housing is highly resistant to impact, as well as oil, water and a host of other liquids. The transducer has been designed for robustness. The portable F608 and G608 feature efficient battery management, and can be set up in less than five minutes, the company says. The units can be used in pipes as small as 0.4 in. (inner dia.) up to 255 in. and in temperature ranges from 40 to 390F. Flexim Americas Corp., Edgewood, N.Y. www.flexim.com

Circle 12 on p. 72 or go to adlinks.che.com/40271-12

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Kral

Focus
These owmeters are optimized with a new sensor system Several series of this companys Volumeter flow measurement system (photo) are being optimized with a new sensor system that increases the maximum temperature for the OMG and OMH Series from 150 to 180C and provides better resolution. The sensor is an all-in-one solution that measures flow amount, flow direction and temperature. Due to to miniaturization and system integration, a single sensor is now sufficient where three sensors used to be required, the company says. The new sensor is designed to make connecting to the Volumeter easier. Kral AG, Lustenau, Austria www.kral.at These Coriolis meters are compact The Sitrans FC430 is a Coriolis flowmeter said to be the most compact flow measurement solution on the market. The digitally

based Sitrans FC430 has a short build-in length, and is suitable for any liquid or gas application in the chemical process industries. The instrument is ideal for multiparameter measurement, and can be used effectively in applications such as fast-filling, batch control, blending and dosing, as well as for measurement of gases or fluids. In addition to the market-leading compactness, the Sitrans FC430 also can perform with 0.1% accuracy, low pressure loss and a stable zero point, the company says. Siemens AG, Industry Sector, Industry Automation Division, Nuremburg, Germany www.siemens.com
This magnetic owmeter is for large sizes The AdMag AXW series of magnetic flowmeters are available in sizes from 20 to 40 in., and are ideal for industrial process lines, water and other basic applications.

The AXW series is designed for outstanding reliability and ease of use, and has a wide selection of liner materials, such as PTFE, hard rubber and polyurethane. The product comes standard with ASME, AWWA, EN, JIS or AS flanges. A submersible version is also available, the company says. The AXW also has a shorter face-toface dimension for a smaller footprint and easier installation. Yokogawa Corp. of America, Newnan, Ga. www.yokogawa.com/us Scott Jenkins

Content Licensing for Every Marketing Strategy


Marketing solutions t for:

Outdoor Direct Mail Print Advertising Tradeshow/POP Displays Social Media Radio & Television

Logo Licensing | Reprints | Eprints | Plaques


Leverage branded content from Chemical Engineering to create a more powerful and sophisticated statement about your product, service, or company in your next marketing campaign. Contact Wrights Media to nd out more about how we can customize your acknowledgements and recognitions to enhance your marketing strategies.

For more information, call Wrights Media at 877.652.5295 or visit our website at www.wrightsmedia.com

Circle 1 on p. 72 or go to adlinks.che.com/40271-01 32
CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Pamas Partikelmess- und Analysesysteme

Endress+Hauser Messtechnik

Almatec Machinenbau

A retractable assembly for sterile pH measurements The Cleanfit CPA875 pH retractable assembly (photo) provides reliable protection against bacterial contamination of processes, thus making it suitable for safe, automated pH measurement in sterile processes. The Cleanfit assembly is made of 1.4435/316L stainless steel with smooth, electropolished surfaces (Ra less than 0.76), and seals manufactured according to U.S. Food and Drug Administration (FDA) class VI. The newly designed rinse chamber and dynamic seal allow movement of the assembly in and out of the process free from interference. For demanding applications and highly toxic chemicals, a double chamber is available as an added safeguard. The new assembly meets all standard regulations for the life sciences and food industries. The Cleanfit can be installed directly in a pipe or on a boiler. Endress+Hauser Messtechnik GmbH & Co. KG, Weil am Rhein, Germany www.endress.com This new pastillation machine requires less maintenance The new Rotoform 4G system (photo) is the latest generation of this well-known solution for granulating a wide range of chemical melts, including sulfur, waxes, resins and agrochemicals. The Rotoform family now numbers ten different models, each meeting the needs of a different sector. System enhancements in the 4G include: a redesigned pneumatic re-feed bar, which is raised to the correct operating position at the touch of a button. Automatic positioning of this heated bar ensures that any surplus material left on the depositor

Sandvik Process Systems

is forced back through a channel in the Rotoform, where it is remixed with product and returned to the production process. Another feature is the new bearing unit, which is fitted with enhanced mechanical seals that improve reliability and reduce maintenance work. A significantly reduced product dead zone also ensures a lower maintenance requirement, says the company. Sandvik Process Systems, Fellbach, Germany www.processsystems.sandvik.com Leaks are minimized in this AODD pump The new E-Series Plastic AODD (airoperated double diaphragm) pumps (photo) feature no mechanical seals or packing, thereby eliminating a critical leak point. Instead, these pumps have a stainless-steel containment ring that creates consistent high-torque compression all the way around the ring, pulling the components tighter together and eliminating a potential leak path. Due to its metal core, the E-Series does not require diaphragm discs, which frequently give rise to

leaks and attract contaminants. The ESeries is available in seven sizes from 6 to 76 mm, with maximum flows to 800 L/min and heads of 5 m dry (9.5 m wet). The pumps handle temperatures to 120C and a maximum solids size of up to 15 mm. Almatec Machinenbau GmbH, Kamp-Lintfort, Germany www.almatec.de Count and analyze particles in small-volume samples The Pamas SBBS laboratory particle analyzer system has been upgraded to be equipped with an optional, small pressure-vessel container (photo) for handling small sample volumes (15 mL) of high-viscosity liquids, such as protein solutions. This new integrated pressure container is used to create either a high pressure or a vacuum atmosphere that is safely enclosed within a locked container. High pressure is used to transport the viscous liquid through the sensor for measurement, whereas the vacuum is used for removing bubbles from the sample. The new, smaller pressure container was developed for applications in the
32I-1

Note: For more information, circle the 3-digit number on p. 72, or use the website designation.

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Afriso-Euro-Index

New Products
Kreyenborg

pharmaceutical industry. Pamas Partikelmess- und Analysesysteme GmbH, Rutesheim, Germany www.pamas.de Boost productivity with this continuous lter-screen changer This company has equipped several plants for the production of blown film with continuous screen changers of the type K-SWE (photo). The screen changers were equipped with a separate control to guarantee smooth and reliable filter change during operation. The retrofit should eliminate production-line shutdowns during filter change and improve filtration results, thereby increasing plant availability and productivity. The K-SWE screen changer enables the exchange of the mesh without interrupting production; conventional blown-film plants use discontinuous screen-changer systems that require the line to shut down for filter changes. Kreyenborg GmbH, Mnster, Germany www.kreyenborg.com Aseptic globe valves for pure steam applications The new GEM 505 (hand-operated; photo) and 555 (pneumatic) angle seat valves were developed for pure steam shutoff valves, and are available in nominal sizes from DN 8 to DN 80. The valves provide an alternative to the valve types that have usually been employed up to now. In contrast to 90-deg turn valves, such as ball valves or butterfly valves, the handwheel does not rise in height when the valve is manually operated, so it is now possible to open the valve slowly and steadily. As a result, the steam does not flow sud32I-2
GEM Wika Alexander Wiegand

denly into the piping system when the valves are opened. The valves also require significantly less maintenance than diaphragm valves, especially at the high temperatures produced by the stream, says the manufacturer. GEM Gebr. Mller Apparatebau GmbH & Co. KG www.gemue.de Detect gas leaks at the source with this handy device The portable GSP3 and GSP3 Flex (photo) gas detectors are designed for fast and reliable detection of leaks of inflammable gases at gas pipes and connections, gas meters, gas burners and gas tanks. The GSP3 Flex is equipped with a flexible gas probe to allow for the detection of leaks in areas difficult to access. The sensor is suitable for detecting methane, propane or butane, and covers the measurement range of 0 to 2,000 ppm (methane) at a sensitivity of 20 to 50 ppm. Afriso-Euro-Index GmbH, Gglingen, Germany www.afriso.de A hygienic actuator that requires less space The MFO actuator (photo) from the proven 812/813 Series is a pneumatic actuator that was specially designed to be compatible with sterile and fine-

ARCA Regler

chemical applications, and is particularly well suited for the tight space requirements associated with prefabricated system components. This diaphragm actuator is said to be the first to integrate the fully welded construction of the actuator chamber as used on piston actuators in sterile processes. The design facilitates extremely small dimensions and maintains a specified diaphragm of 143 cm2. The circular formation of bolts that affix the diaphragm in conventional diaphragm actuators has been eliminated, to provide a smooth, easy-to-clean surface that is free of bolt heads and other sharp edges. ARCA Regler GmbH, Tnisvorst, Germany www.arca-valve.com Measure temperature, even if theres a loss of power The new TGT73 (photo) is the third mechatronic product of the intelliTHERM family a hybrid concept derived from pressure measurement technology. With the new thermometers, temperatures can be precisely controlled and adjusted; in the event of power loss, the analog display guarantees a correct measured value. The

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Circle 30 on p. 72 or go to adlinks.che.com/40271-30

sera ProDos

New Products
Brkert Fluid Control Systems

TGT73 has a scale range from 200 to 600C, with available output signals of 420 mA and 010 V. For its new gas-actuated thermometer available in nominal sizes of 100 and 160 the company has applied for ATEX approval and GOST-R certification. Wika Alexander Wiegand SE & Co. KG, Klingenberg, Germany www.wika.de A transmitter with two more sensor inputs The modular multichannel multiCell transmitter/controller type 8619 is an individually adjustable measuring system with extended functionalities that can be used with a wide range of sensors. This system is now extended with the addition of a new signal input board (photo) that can be used for direct connection of up to two additional flow sensors via the digital inputs and two additional measurement devices of various types via the analog inputs. The plug-in board features two 420-mA signal inputs for any type of transmitter with a suitable output, including pressure, level or analytical devices, such as turbidity, oxygen, free chlorine and ozone. Brkert Fluid Control Systems, Ingelfingen, Germany www.burkert.com A modular dosing system built to match the task The Compact Vertical Dosing (CVD) system (photo) features a modular design that makes it possible to add or replace fittings and components during, or even after commissioning and without cost-intensive modifications. The design includes standardized components (dosing pump, valves and so on) as well as standardized optional accessories, such as pulsa-

tion dampeners and terminal boxes for the electrical components. Safety upgrades, such as collecting basins, splash guards, leakage sensors and diaphragm rupture indicators, ensure the optimal level of protection for the environment, the system and the operator. Three dosing systems are available under the CVD1 designation, with delivery rates of up to 60, 550 and 1,500 L/h. sera ProDos GmbH, Immenhausen, Germany www.sera-web.com Save energy with these laboratory reaction stations Compared with the use of hotplate stirrers or heating mantles, the Stem RS, Stem Omni and Stem Integrity Reaction Stations can reduce energy costs by as much as 90%, says the manufacturer. Equipped for parallel synthesis, these lab-in-a-box alternatives to traditional heating, cooling and stirring systems consume as little as 300 W, making them energy efficient and inexpensive to run. In comparison, hotplate stirrers generally consume between 550 and 950 W, says the company. The three Stem ranges increase laboratory throughput by providing precise control of heating, cooling and stirring, from 30 to 300C. They can accommodate between six and 50 vessels simultaneously, and will run unsupervised. Bibby Scientific Ltd., Stone, U.K. www.bibby-scientific.com

Circle 7 on p. 72 or go to adlinks.che.com/40271-07

Pumps Valves Systems


KSB SuPremE the worlds most efcient magnet-less pump motor.


The new KSB SuPremE-motor generation cuts energy costs by up to 70%*. Already satisfying tomorrows IE4 efficiency requirements (to IEC (CD) 60034-30 Ed. 2), and doing completely without magnetic materials, its total environmental footprint is significantly smaller than that of comparable permanent-magnet synchronous motors and asynchronous motors. The combination of durable materials and robust design gives the new motor unparalleled longevity. Start getting your equipment ready for tomorrow today.
www.none-more-efcient.com * Depending on the load prole, with centrifugal pumps, compared with throttle control and IE2 asynchronous motors Circle 18 on p. 72 or go to adlinks.che.com/40271-18

New Products
Fr. Jacon Shne

Bag unloading is more exible with this system This new Mobile Half-Frame Bulk Bag Unloader (photo) integrates a multipurpose hopper with a flexible screw conveyor to create a unit that can improve plant efficiency by easy repositioning to accommodate alternative bulk-delivery stations as well as manual bag discharge. The bulk bag unloader can be supplied in carbon steel with durable industrial coating, or stainless steel to food, dairy and pharmaceutical standards. The hopper is designed to accept material from either manually dumped sacks or direct overhead bulk bags suspended by a forklift or hoist. During discharge, the screw conveyor transfers material powder, flakes and granular to the downstream process vessels. Flexicon (Europe) Ltd., Herne Bay, Kent, U.K. www.flexicon.co.uk

Flexicon

Two more sizes added to this pipework system Two new diameters extend the diversity of this companys modular-pipework system (photo) for handling bulk goods, dust extraction and exhaust air. Introducing these two new nominal diameters of 280 and 315 mm adds an extra 250 products to the range, which starts at 60 mm, and includes pipes,

segments, bends, branches, spouts, inspection pipes, shutoff valves and more. The quick assembly, lightweight system is available in powder-coated steel, stainless steel and chromenickel steel in wall thicknesses of up to 2 mm. Fr. Jacon Shne GmbH & Co. KG, Porta Westfalica, Germany www.jacob-rohre.de Gerald Ondrey

Mass Flow meters & controllers

meters & controllers


Industrial style, IP65 protected

Get Chemical Engineerings plant cost index to improve plant cost estimatesand delivered in advance of the print edition!
For more than 37 years, chemical process industries professionals- engineers, manager and technicians, have used Chemical Engineerings Plant Cost Index to adjust process plant construction costs from one period to another.
BHT2011-027

This database includes all annual archives (1947 to present) and monthly data archives (1970 to present). Instead of waiting more than two weeks for the print or online version of Chemical Engineering to arrive, subscribers can access new data as soon as its calculated.

Gas flows from 0-1 mln/min to 0-11.000 m3n/h High accuracy, excellent repeatability Analog / RS232 / Profibus-DP / DeviceNetTM IP65 protection, option: ATEX Zone 2 approved NEW: CTA-series for low pressure drop; insensitive to moisture or particulates Outstanding price / performance ratio

Resources included with Chemical Engineerings Plant Cost Index: Electronic notiication of monthly updates as soon as they are available All annual data archives (1947 to present) Monthly data archives (1970 to present) Option to download in Excel format
17817

Innovation - Experience - Excellence

Subscribe today at www.che.com/pci


www.bronkhorst.com - [email protected]

Circle 4 on p. 72 or go to adlinks.che.com/40271-04 32I-6


CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

We know what makes a

GOOD POWDER

To make superior powders, look for a GEA Niro drying system. We specialise in supplying industrial drying systems designed to match your exact product and plant specications, and with more than 10,000 references worldwide our expertise is unsurpassed. Our comprehensive product range includes GEA Niro spray dryers, uid bed systems, spray congealers and the SWIRL FLUIDIZER. At our extensive test facilities, the most experienced test engineers and process technologists in the business will help you move rapidly from idea to product development and protable production.

GEA Process Engineering A/S


Gladsaxevej 305, PO Box 45, DK-2860 Soeborg, Denmark Tel: +45 39 54 54 54, Fax: +45 39 54 58 00 [email protected], www.niro.com

engineering for a better world

GEA Process Engineering

Circle 13 on p. 72 or go to adlinks.che.com/40271-13

Pompetravaini Group, the Heart of the plant Since 1929, the italian Excellence in the world

New name but old tradition at the top of technology:

SB Compressor skid for are gas recovery

Combivac System

SB Compressor

Our commitment is always to stay ahead

Pompetravaini-NSB ag Reinacherstrasse, 129 CH-4053 Basel - Swizterland Pompetravaini Group [email protected] www.pompetravaini.it
Circle 27 on p. 72 or go to adlinks.che.com/40271-27

Ph. +41 61 338 18 18 Fax +41 61 338 18 00 [email protected] www.pompetravaini-nsb.com

Gas Sparging
Department Editor: Scott Jenkins
parging refers to the process of injecting a gas through a diffuser into a liquid phase. It is used in both physical and chemical process applications. In physical process applications, the gas is used to either dissolve gas into liquid (such as aeration and carbonation) or to remove contaminants from the liquid phase (such as oxygen stripping, volatile organic compound stripping and water stripping). In chemical process applications, sparging is used to dissolve reactant gases into a liquid phase for further reaction (such as in hydrogenation, oxidation, fermentation and ozonation reactions). The following information discusses some of the considerations required for setting up a sparging operation and selecting sparging equipment. Spargers (diffusers) come in various sizes, congurations and materials of construction. They are chosen based on the design and operating conditions of the process. Metal spargers are used in high-temperature, corrosive or oxidizing conditions, whereas ceramic spargers are sufcient for mild conditions. The type and conguration of the sparger used depend on factors such as whether a process is continuous or batch, gas owrate, tank size, mechanical agitation, operating pressure and temperature.
Normalized nitrogen flowrate

Mass-transfer rate
The main purpose of a sparger is to increase the gas-to-liquid mass-transfer efciency, which is the ratio of the amount of active gas component (that is dissolved in liquid) to the gas injected. A low efciency will result in an increased gas-injection rate and therefore increased cost to achieve the desired results. The liquid-phase masstransfer resistance primarily controls the gas-to-liquid mass-transfer efciency. The gas-to-liquid mass-transfer rate per unit volume is given by KLa(C* C). In this equation, KL is the liquid-phase masstransfer coefcient that is dependent on the diffusivity, liquid viscosity, temperature, and mixing; a is the interfacial area of gas bubbles in contact with liquid; C* is the saturated concentration of the gas in liquid; and C is the concentration in bulk liquid. As the interfacial area a is increased by sparging small gas bubbles with high surface-tovolume ratio, the gas mass-transfer rate is improved. The mass-transfer driving force (C* C) also has a big impact on the gas dissolution rate as the high-purity gas is used instead of the lower-purity gas. For example, the saturated concentration of oxygen in water from pure oxygen is ve times higher than that from air, resulting in a large increase in the oxygen dissolution rate with pure oxygen.

important design criterion for sparger selection. The actual gas volumetric owrate for exit velocity is calculated using the pressure (P) that is the sum of tank headspace pressure (PHeadspace), liquid head pressure at the sparger (PLiquid), and pressure drop across the sparger element (P). The minimum sparger surface area is based on the gas exit-velocity limit for the process. The exit velocity limit is lowest for the static sparging operation when there is no mechanical agitation of the liquid phase. For agitated tank sparging and dynamic sparging, where liquid has high forced velocity along the sparger surface, the gas exit-velocity limits are signicantly higher, requiring smaller spargers for the same gas ow. The exit-velocity limit for agitated tank sparging and dynamic sparging depends on the impeller speed and liquid velocity, respectively.

120 100 80 60 40 20 0 200 F, 14.7 psi 200 F, 10 psi 150 F, 10 psi 200 F, 7.5 psi

FIGURE 1. Normalized nitrogen gas lowrate for moisture removal from biodiesel

2,500 14.7 psi 2,000 10 psi

Water, ppm

1,500

1,000

500 0 10 20 30 Time, min 40 50 60

FIGURE 2. Moisture concentration in biodiesel with nitrogen gas sparging at 200F

Agitation effects
Apart from using a properly designed sparger, it is important to focus on the mixing of gas and liquid. In chemical process applications, the reactor vessel is often closed so that the unreacted high-purity gases, such as hydrogen or oxygen, are not vented through the system. In these applications, specially designed mixing impellers are used, depending on the operating conditions of the reactor. Typically, one impeller turbine is located above the sparger to shear and disperse the gas bubbles. Agitation at the liquid surface may also be required to entrain the headspace gas into the liquid phase.

Contaminant removal
In physical process applications where a contaminant is removed from the liquid phase, it is important to estimate the gas required for the process, as well as other components volatilized from the liquid phase. Sometimes downstream processing equipment is required to recover the contaminant from the gas phase before venting the sparging gas to the atmosphere.

owrate and vent-gas composition in any sparging application. For example, when a gas is used to remove moisture from biodiesel, the key variables to estimate the gas requirement are temperature, pressure, moisture in inuent gas, biodiesel composition, initial and nal moisture concentration in biodiesel, batch size and batch time. Figure 1 shows the effect of the operating temperature and pressure on the normalized gas owrate to reduce the moisture from 2,000 ppm to 500 ppm in a batch process using pure nitrogen gas (~99.99% purity). The gas- and liquid-phase compositions can be estimated using the vaporliquid equilibrium calculations. Figure 2 shows the calculated moisture concentration in biodiesel at 10-psi and 14.7-psi operating pressures for processes at 200F with 1-h batch time. The moisture concentration in both processes reduces from 2,000 ppm initial concentration to 500 ppm nal concentration after sparging, but the process with 10 psi pressure requires 37% lower gas ow. This reduces the nitrogen consumption, as well as the biodiesel vented with the gas.
Editors note: Content for this edition of Facts at Your Fingertips was contributed by Air Products (Allentown, Pa.; www.airproducts.com).

Sparging equipment selection


There are several important factors to consider when selecting a sparger. The gas exit velocity at the sparger surface is an

Biodiesel example
Many parameters have to be taken into consideration when estimating the gas

Feature Cover Story Report

Condition Monitoring Methods for Pumps


Applying condition monitoring tests to pumps can save costs by optimizing overhaul scheduling
Ray Beebe MCM Consultants Pty Ltd. and Monash University
several condition-monitoring tests for pumps, and discusses how to use these predictive-maintenance methods to estimate the increased power consumption that results from pump wear (Figures 1 and 2). Experience in the field or with an original equipment manufacturer (OEM) may help pump operators determine when to undertake overhauls, but others may not have an idea of how to determine the optimal time, because many pump textbooks, even excellent and widely used ones, have failed to cover the application of condition monitoring to pumps in detail, and information in this area has been lacking until recently [1, 2]. It is hoped that the tools presented in this article will help asset managers and engineers improve management of pump assets to provide capacity for production, as well as improve energy efficiency and minimize greenhousegas emissions. Although the article focuses on pumps, the optimization approach described here can also be applied to other plant equipment where deterioration results in efficiency loss, and where energy consumption can be measured or estimated.

umps are among the most commonly used machines in the chemical process industries (CPI). Condition monitoring tests and predictive maintenance can help pump operators determine when to overhaul pumps in a way that minimizes costs. Despite pumps ubiquity and large energy demands, however, relatively little information is available on how to apply predictive maintenance approaches and condition monitoring to process pumps. Pump overhauls may occur on a fixed time schedule or as a result of a specific breakdown, but neither case necessarily represents the most cost-effective policy. In cases where deterioration in the performance of a centrifugal pump causes a drop in plant production, pump overhaul is readily justified, because the cost of performing the overhaul is usually small compared to the losses from reduced production. However, when pump performance deteriorates due to wear and the only effect is increased power consumption (with no discernable effect on production), the question of when to perform an overhaul becomes important. The right time to overhaul that minimizes cost can be calculated from predictive maintenance test results. The use of condition monitoring methods ensures that pump overhauls aimed at restoring performance are executed when they are actually necessary. This article describes

FIGURE 1. Pump wear, such as that shown on this pump impeller, can lead to reduced pump performance

FIGURE 2. The degree of pump wear is expressed as the percent reduction in total head

Choosing monitoring methods


The extent and specific effects of internal wear in centrifugal pumps vary according to the characteristics of the liquid being pumped, as well as the type of pump and its operating duty. Some pumps last for years, while others last for only months. Pump monitoring methods (where justified) should be chosen that can

detect each of the pump degradation modes that are either experienced or expected. Common pump-monitoring methods include the following: Vibration monitoring and analysis: probably the most widely applied method of condition monitoring for rotating machines in general, and suited to detect such faults as unbalance, misalignment, looseness Sampling and analysis of lubricants for deterioration and wear debris: relevant for bearings and

34

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

18 16

Reduction in head, %

14 12 10 8 6 4 2 0 0 12 10 8 6 4 2 0 0 2 4 6 8 Time since overhaul, years 10 12 500 1,000 Days in service 1,500

Reduction in head at normal flow, %

FIGURE 3. The degradation of pump performance can be shown by the percent decrease in total head at normal-duty low, and can be determined by head-low testing (Top graph, 230 kW; Bottom graph, 5,744 kW)

lubrication system faults Electrical plant tests: relevant for motor condition Visual inspection and non-destructive testing: particularly relevant for pump casing wear Performance monitoring and analysis: relevant for pump internal conditions For critical machinery, the use of more than one method of condition monitoring in combination may be justified. This article demonstrates the use of performance analysis and includes some examples of condition monitoring in practice. An understanding of basic pump performance characteristics is assumed, as is how to measure test data in a repeatable manner. For condition monitoring, repeatability is more important than absolute accuracy.

Head-flow method shows wear


The most useful condition-monitoring method is head-flow measurement, because in addition to pump deterioration, it also detects any changes in system resistance. This method can be used for all pumps where flow (or some repeatable indicator of flow) can be measured. Figure 3 shows the trend in degradation of two pumps over multiple years. The degree of wear is expressed as the percent reduction in total head due to

wear, compared with the pumps new condition, at duty-point flow. This is usually derived from head-flow tests near the duty point, but can also be obtained using the shut-off head test, where this test is allowable. Regular interrogation of the plant historian can be used if a plant has a DCS (distributed control system). Figure 3 (bottom) shows data for a multistage boiler-feed pump (specifically, a constant-speed, four-stage pump; 5,853 rpm; 5,744 kW; 171 kg/s at 20.4 MPa). Data points are extracted every six months from a run of 10 days at a steady load. Performance information such as that shown in Figure 3 can reveal the extent to which a pump has deteriorated, and pumps can be prioritized for overhaul on the basis of their relative wear. The question becomes whether an overhaul of the worst-performing pump is justified economically. (The article will revisit this question and provide a method for helping to make the decision later.) Throttling the pump over its full flow range to obtain data points is not necessary for monitoring. Several points near the normal operating duty point are sufficient to reveal the effects of wear, usually shown by a shift in the head-flow curve towards the zero-flow axis by an amount equal to the internal leakage flow.

A series of test readings at steady conditions, at about 15-s intervals, is sufficient. Average values are plotted. Speed must also be measured for variable-speed pumps, and the headflow data must be corrected to a standard speed using the affinity laws for pump performance. Field tests sometimes yield results that are slightly different from the manufacturers works tests because site conditions for flow and pressure measurement (as required by the various standards for pump testing) are rarely available. It is important to remember that for monitoring, relative changes are more important than absolute accuracy. For condition monitoring, nonintrusive ultrasonic flowmeters are acceptable in many cases. A permanent flowmeter installed as part of a pumps minimum flow protection or for process measurement can be used, as long as the flowmeters long-term condition is considered to be constant. Or, it can be inspected regularly.

Shut-off head method


The shut-off head method can be used for predictive maintenance of pumps. While measuring the head at zero flow is a relatively simple test, it is only possible where it can be tolerated by the pump. This is not the case for high-energy pumps, and for pumps of high specific speed where the power at shutoff is greater than that at the duty point. Pumps have exploded from a buildup of pressure when left running at zero flow. To perform the shut-off head test, read the suction and discharge pressures (when steady) with the discharge valve closed fully for no longer than 30 s or so. To convert the pressure readings into head values, the liquid temperature is also needed to determine the density. Wear on the outer diameters of pump vanes will show readily, because the head-flow curve of a worn pump shifts toward the zero-flow axis. To show wear of the sealing ring, the pump head-flow curve needs to be relatively steep. (Note that if the pump has a rising head-flow curve, internal leakage will initially give rise to an increase in shut-off head).
35

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Cover Story
20 L/S High critical High alarm

14.6

5 L/S J J A S O N 1994 M A M J J A S O N 1995

Pump overhauled

FIGURE 4. Condition monitoring of a high-energy multistage pump can be accomplished by measuring the balancedevice leakoff low. (Note: lows shown are corrected to a standard pump speed)

Leakoff flowrate

Months

Thermodynamic method
Another method of pump monitoring is to measure the temperature rise of the liquid through the pump. This measurement is a reflection of the inefficiency of the pump. Because the differential temperature is small, great care is required to measure it. For example, effects of recirculation at the pump inlet and outlet must be eliminated and thermodynamic tests are not possible at low or zero flow. Pump efficiency can be calculated from the measured data of inlet temperature, the differential temperature and the head. If the efficiency changes over time, comparisons can be made on plots of efficiency versus head. For high-head pumps, an allowance must be made for the isentropic temperature rise, which occurs as a result of pressure increase [2]. Commercially available devices are widely used for the thermodynamic method, especially in the water industry [3]. For the installation of pressure and temperature probes, tappings for measuring suction and discharge must be two pipe diameters away from pump flanges. Tong-type detectors are placed to measure motor power. Pump efficiency is then found from the precise measurement of the head and temperature rise through the pump. By assessing motor losses, the power absorbed by the pump can be computed, and from these data, the pump flow can be found. For condition monitoring, tests at around the normal operating point are usually sufficient. The thermodynamic
36

method would be more attractive economically if no special tapping points were required. Research at Monash University (Gippsland, Australia campus) on high-head pumps using special semiconductor temperature probes on the outside surface of the piping (even when covered with insulation) gave usable results, provided the pump was allowed to run at steady operating conditions for 30 min to allow the piping temperature to stabilize [4]. The empirical expression shown below gives the percent efficiency for pumps at up to 54C. The expression includes a correction for the isentropic temperature rise. Total head is in kPa, and temperatures are in C [5].
100 Temp rise 1 0.003( InletTemp 2 ) + 4,160 Total he ead

Measurement of balance flow


Multistage pumps with their impellers facing in one direction usually have a balance disc or drum arranged such that the final-stage discharge pressure counteracts the axial thrust on the shaft line. Another method for pump condition monitoring is to measure the leakoff from the balance device [6]. The basis of the method is that if increased wear in the annular space of the balance device is evident from increased leakoff flow, then the interstage clearances must also be worn. Because the leakoff line is quite small compared to the pump main flow piping, a permanent flowmeter for this

method is relatively inexpensive. Figure 4 shows an example of using leakoff flow to schedule pump overhauls of boiler-feed pumps at a power plant. Flows are read manually, and trends plotted using a database program. Note that here the balance flow (15 L/s) corresponds to about 10% of the regular duty flow, and consumes about 250 kW of extra power. When added to the likely internal recirculation, this would mean that an even larger proportion of the power absorbed is being wasted. The boiler-feed pumps are variablespeed units, and other tests show that the measured flows must be corrected in direct proportion to the speed. On a set of pumps of a different design at another location, both head-flow and balance flow were measured for some years, but no correlation was found between the two. On still another pump type, of the 11 stages, the head-flow performance was determined to be well below the datum curve. As the pump was dismantled, measurements showed that the interstage clearances were not worn. A condition-monitoring credibility crisis was averted when the balance seat area was reached and found to be severely eroded from water leaking past the valve seat. Balance flow had obviously been very high. For the best monitoring, it is therefore desirable that both head-flow and balance flow should be measured, particularly if the balance area can be separately dismantled in the field.

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

900

Head, m

800 700

Site test n

ew pum

p
A C D

Test points worn pump 600 3,000 2,300

E B

2,000

2,150

200

400 600 Flow, m3/h

800

1,000

FIGURE 5. Head-lowpower characteristics of a new pump differ from the data points for a worn pump. Point C to D shows internal leakage low FIGURE 6. The point that optimizes the time to pump overhaul can be shown graphically

Optimum time to overhaul Cost of overhaul/month Total cost/month Cost/month of energy usage

Time, months

Calculating time to overhaul


The most economically cost-effective time to restore lost pump performance by overhaul varies with the circumstances. If the deterioration of pump performance is constant over time, then operators can conduct a cashflow analysis to ensure that investing in the pump overhaul will yield the required rate of return. This analysis is the same process as that used in deciding on any significant investment in plant improvement. If the deterioration rate is increasing with time, then the optimum time for overhaul occurs when the accumulated cost of the increased electricity consumption equals the cost of the overhaul itself. The method for calculating the optimal time to overhaul can be applied to a number of pump-operating scenarios, which are described as follows: Pump deterioration results in a reduction in plant production: Whenever the cost of the overhaul is small or insignificant compared to the cost of lost plant production, prompt overhaul is usually justified at any convenient window. Pumps that run intermittently to meet a demand: In a pumping installation such as topping-up a water supply tank or pumping liquid out of

a tank or vessel, deterioration will result in the pump taking more time to do its duty. Therefore, the extra service time required of the pump results in increased power consumption, and that can be compared to the cost of conducting the overhaul. Pump deterioration does not affect plant production: In some cases, where a pump is operated at constant speed with throttle-valve control, a deterioration in pump performance may not affect plant performance, at least initially. The internal wear does not cause any loss in production from the plant, because the control valve can open more fully to maintain pump output. Eventually, as wear progresses over time, pump output may not be sufficient to avoid a loss of production. Or the extra power consumed will exceed the motor rating. Figure 5 shows the head-powerflow site-test characteristics of such a pump. Its output is controlled using a throttle control valve. The duty flow is 800 m/h, and the duty point in the new condition is represented in Line A. The power absorbed by the pump is read off the power-flow curve (2,150 kW; Line B). The power-flow curve should ideally be found onsite, but information from the works tests may have to suffice.

After some service, the data points marked on the diagram as Test points worn pump indicate that internal wear has occurred. When worn to this extent, the operating point moves to Point C (the system resistance curve moves lower when the throttle valve is opened further). The increased power required in the worn condition can be estimated by extending from the head-flow curve at constant head from the operating point to Point D, and then dropping straight down to the point where the the powerflow curve intersects for the new condition at constant flow: Point E. Next, follow the arrowed line in Figure 5. It is assumed that the original curve still represents the flow through the impellers. Less flow is leaving the pump to the system due to internal wear. (If the pump was motor-driven, it may be possible to measure the actual power by a test at extra expense). In the example, the power required for this duty in the worn condition is shown in Figure 5 by the projection from the duty flow of 800 m3/h to the test curve to find 640 m of head, then by moving across to the site test new pump curve, and down to the power curve, to find 2,300 kW. The extra electricity consumption is therefore 2,300 2,150 = 150 kW, which is then divided by motor efficiency (90%, in this case), to obtain 167 kW of extra consumption. If the sealing clearances are known (either by previous experience of correlation with measured performance, or if the pump is opened up already), operators can estimate the extra power consumed that will likely be saved as a result of an overhaul [1, 8]. Finding the optimum time for overhaul from head-flow data. For this example (Figure 6), the test points were obtained following 24 months of service (the pump was known to be in new condition at the start). An overhaul would cost $50,000, with electricity costs of $0.10/kWh and with the pump in service for 27% of the time, on average. The increased power consumption is estimated at 167 kW (with motor efficiency included in the total). The test discussed here shows that the rate of increasing cost per month has reached 167 0.10 0.27 720
37

Power, kW

Cost per month, $

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Cover Story
Head, m

120 100

Head a

t 1,660

rpm ( new)

A 80 6 0 B
rpm t 1,490 Power a

C Head at 1,490 rpm (new) Head at 1,660 rpm (worn)


(new)

600 500

= $3,246/mo (using an average month as 720 h). As the time that the pump has been operating now is 24 months, $3,246 24 gives the average monthly cost rate of deterioration as $135/mo. The optimum time for overhaul (T) is calculated [7] from Equation (1). T= 2O C

425 325

400 300

1,000

1,200

1,400 Flow, m3/h

1,600

1,800

FIGURE 7 For variablespeed pumps, the effect of wear on power required for operation is more dramatic than constantspeed pumps

(1) where O = cost of overhaul and C = cost rate of deterioration. This calculation yields an optimum time to overhaul of the pump of 27.2 months. It is better to calculate and plot the average total cost-per-month values for a range of times. Doing so will allow the cost impact of undertaking the repairs at another time (such as at a scheduled plant shutdown), to be seen clearly.

Average cost, month by month


For an example, use the time period of 22 months. The average cost of conducting the overhaul is now $50,000 22 = $2,273/mo. The average cost of extra energy consumed is then ($135 22) 2 = $1,485/ mo. Total average cost per month is the sum of these two figures: $3,578/mo. Since pump wear progresses linearly, the cost per month also is linear and the average can be obtained by dividing by two (at the starting time, the value is zero, and the average over the time period is given by the ending value minus the start value, divided by two). Repeat this calculation for several months (the use of a spreadsheet can be helpful) and look for the minimum total cost, which is at 27.2 months. If plotted as cost per month against time, the resulting curves will show that the cost per month of overhaul drops over time, and the cost of extra energy increases with time. The time value of money could also be taken into account, if required. Usually the total cost curve is fairly flat for 20% or so. The calculations can be easily set up using a spreadsheet. If the overhaul was delayed until the 30-month mark, for example, then the accumulated cost of lost energy would have reached $135 0.5 30 = $60,750. At 27.2 months, the cost is $135 0.5 27.2 = $49,939. The cost
38

of delaying overhaul is thus the difference between the two ($10,811). This calculation is only correct if the wear progresses at a rate that increases uniformly with time. As Figure 3 shows, this is not unusual. Information may not be available to make any other assumption, but decision makers have to start somewhere. Other formulas apply for nonlinear rates of change [7]. Some notes and additional points to consider regarding these calculations are as follows: Some relatively small pumps may never fully justify an overhaul on savings in energy use alone, but the overhaul may be justified on reduced plant-production rate The method does not apply to pumps of high specific speed that show little change, or even a reduction, in power with increased flow If a pump varies in its duty, then the energy usage would be corrected in proportion The cost of electricity to be used here may vary with the power suppliers tariff structure. The cost may be less in stepped blocks with higher consumption levels for the plant, or a peak-demand charge may apply Pump deterioration does not affect production (variable-speed control): In situations where a pump has variable-speed control, and performance deterioration does not (at least initially) affect production, the following steps can be taken. For a pump where the speed is varied to meet its desired duty, the effect of wear on power required is much more dramatic than for the case of a constant-speed, throttle-controlled pump. This is because the power usage increases in proportion to the cube of the speed ratio. Unless the pump output is limited by the pump reaching its maximum speed, or by its driver reaching its highest allowable power output, then

no production will be lost. However, power consumed will increase more dramatically for a given wear state than that for a constant-speed pump. To estimate the power required in the worn state, the head-flow curve must be drawn for the current higher speed in the new condition. Select a head-flow point on the original, newcondition curve, and correct it to the higher speed by multiplying the flow by the speed ratio and multiplying the head by the square of the speed ratio. Repeat this for several other points at flows above regular-duty flow to draw the new condition headflow curve. Follow the same method and calculations as in the previous section to find the time for overhaul at minimum total cost. The operating point is projected from the worn curve to the new curve at the same speed as the worn curve. Figure 7 shows the performance of a variable-speed pump. When new, operation at 1,490 rpm meets the desired duty flow, at operating Point A, requiring 325 kW of power (Point B). After some period of service, internal leakage has increased to the extent that the pump must run at 1,660 rpm to meet the required duty (still Point A). To estimate the power required now, the head-flow curve must be drawn for the higher speed in the new condition. Several head-flow points are selected and corrected to the higher speed. To do this, multiply each flow by the speed ratio, and multiply each matching head by the speed ratio squared. This will result in the head-flow curve at 1,660 rpm in the new condition. Project across from the head at the duty flow (Point A) to meet the headflow curve at 1,660 rpm (new condition; Line C in Figure 7). Projection downward at a constant flow leads to the increased power required at 425 kW. The

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Power, kW

extra power is 31% more. (This pump is driven by a steam turbine, so power consumption cannot be measured). The same calculations as those presented in the previous section are followed to find the time to an overhaul that minimizes total cost.

Using shut-off head test results


The shut-off head test information can also be used to estimate the power used in the worn state, and to perform

the optimization calculations as explained in the above section. Head-power-flow characteristics in the new state are needed as before, and the operating point must be known. Note the power required at the operating point, as before. Make an overlay trace of the headflow curve in the new condition. Place it over the new curve and move to the left horizontally until the curve cuts the head axis at the value of the
rity and Maintenance), September 2527, 2002, Cairns, Australia. 5. Whillier, A. Site testing of high-lift pumps in the South African mining industry. IMechE paper C155/72, Conference on Site testing of Pumps. London, pp. 209217. 6. Karassik, I.J. and others (Eds.). Pump Handbook McGraw-Hill, New York, 2001. 7. Haynes, C.J., and Fitzgerald, M.A. Scheduling Power Plant Maintenance Using Performance Data, ASME Paper 86-JPGC-Pwr-63, 1986. 8. Stepanoff, A.J. Centrifugal And Axial Flow Pumps. John Wiley & Sons. Hoboken, N.J. 1957, and Figure 1-77A of the PDF figures found at www.pumps.org.

shut-off head obtained on the test. The trace is now in the position of the worn head-flow curve, which is being experienced. Exactly the same process as that explained above can be followed. Edited by Scott Jenkins

Author
Ray Beebe (Phone: +61-408178-261; Email: ray.beebe@ monash.edu) works part-time since retiring after a 20-year tenure as a senior university engineering lecturer at Monash University (Gippsland campus, Victoria, Australia) and an engineering consultant with 28 years of experience in the power generation industry. His commitment to sharing knowledge and experience has led to writing and presenting at many conferences and conducting training courses in condition monitoring around the world. His second book gained the George Julius Medal of Engineers Australia for the best publication in mechanical engineering in 2004. His third book, on condition monitoring of steam turbines will be published later this year. He is an active volunteer in rotary and scouting. Beebe received a diploma of mechanical engineering from the Caulfield Institute of Technology, and an M.S. in engineering science from Monash University.

References
1. American National Standards Institute. American National Standard for Centrifugal and Vertical Pumps for Condition Monitoring. ANSI/HI 9.6.5-2000. 2. Beebe, R.S. Predictive maintenance of pumps using condition monitoring. Elsevier, London. 2004. 3. Robertson, M. and others. Continuous Pump Performance Monitoring and Scheduling. IMechE Symposium Energy Savings in Pumps and Pumping, London, 2007. 4. Beebe, R.S. Thermometric testing of highenergy pumps using pipe surface measurements. Paper presented at the 3rd ACSIM (Asia-Pacific Conference on Systems Integ

The Chemical Engineering bookstore offers a variety of industry topics you will come to rely on.

Multidechlorobac
Rapid and sustainable decontamination of soil and groundwater
Environmental Management: Air-Pollution Control Environmental Management: Wastewater and Groundwater Treatment Fluid Handling Gas-Solid and Liquid-Solid Separation Liquid-Liquid and Gas-Liquid Separation Managing Bulk Solids
17792

The safe and validated bacterial culture for the anaerobic degradation of chlorinated ethanes and ethenes in soil and groundwater. Degradation of 100 000 g 1,2-DCA/L in 10 days in the ield!

For a complete list of products, visit the Chemical Engineering bookstore now. http://store.che.com/product/book

Avecom nv Wondelgem Belgium T: +32 9 375 17 14 [email protected]

www.avecom.be
Circle 3 on p. 72 or go to adlinks.che.com/40271-03

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

39

Feature Report

Thin-Film Drying Offers Deep Benefits


This continuous drying technology is especially safe and flexible, and offers many benefits, including low operating costs, low space requirements and high specific-evaporation capacity
Georgios Raouzeos Buss-SMS-Canzler GmbH
ontact agitated dryers are used for drying wet powders, slurries, filter cakes, and applications where off-gases during the drying cycle must be contained. If the applications are also heat-sensitive, such as specialty chemicals, polymers, food products and pharmaceuticals, contact drying must take place at low heating temperatures, at residence times in tune with the tolerance of the product, and occasionally in conjunction with a heated sweep gas (stripping medium). These operating conditions plus the ever-present wall fouling by the product, considerably reduce the effectiveness of commonly used agitated dryers (for instance, paddle dryers and disc dryers) to the extent that they become inefficient. Therefore, there is a strong demand by the chemical process industries (CPI) for a high-performance, continuous agitated dryer. Thin-film drying technology (TFDT) meets these challenges. Instead of a heated sweep gas, thin-film dryers (TFDs) operate at
40

TABLE 1: CLASSIFICATION, MODE AND RANGE OF OPERATION


Classification Mode of operation Continuous Range of operation Batch Heating Operating temperature, pressure, C bars 0 ~ 700 0 ~ 700 0.01 30 0.01 30 Residence time, min 0.15 2 0.15 30

Vertical Horizontal

TABLE 2: SELECTION CRITERIA ACCORDING TO THE CONSISTENCY OF THE FEEDSTOCK


Type of dryer Consistency of feedstock Solution, suspension Slurry Thixotropic paste (pumpable) Pasty (hardly pumpable) Filter cake Crumbly to free flowing Granular (mm range) Very coarse (cm range) Fibrous = Suitable; = Conditional; = Not suitable Vertical Suitability Horizontal

a reduced pressure (0.01 bar or even lower). Retention time, which is normally measured in hours for paddle and disc dryers, is measured in minutes or even in seconds, and the fouling problem a common deficiency of conventional agitated dryers is eliminated or controlled. TFDT is characterized by a low consumption of utilities and consequently of operating costs (1.15 kg saturated steam per 1 kg of evaporated water), compact construction (and hence low space requirements) and high specific evaporation capacity. These major features make TFDT economical. It offers operational flexibility, feedstock adjustability and simple handling. Meanwhile, low product holdup and product containment has earned TFDT the rec-

ognition of safe processing technology. The thin-film principle is widely used for evaporation of temperaturesensitive specialty chemicals, polymers, food products and pharmaceuticals, plus a growing list of other materials (for more, see box entitled Typical applications). Applying this principle to the drying of solids involves only a modification of the well known thin-film evaporation principle to now handle salt solutions, polymer solutions, slurries, semi-solids, press cakes and wet powders from the CPI. Whether a vertical or a horizontal thin-film dryer (TFD) type is appropriate depends on a variety of parameters, which are explained below. Applications for both TFD types are provided as illustrative examples.

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

TYPICAL APPLICATIONS

enerally, thin-film dryers are used for drying crystalline type powders or filter cakes, which tend to agglomerate or adhere to heating surfaces during drying. More specifically, applications for thin-film dryers exist in such areas where the material to be dried is temperature-sensitive or where an auxiliary sweep gas is not satisfactory. A very small sample of applications is shown in the table below, classified according to the type of dryer.

FIGURE 1. Product hold-up in a batch paddle dryer (left) is much larger than that achieved in an h-PTFD

SHORT LIST OF EXAMPLE APPLICATIONS


Type of dryer Application Glycerine separation and recovery Saline effluents and residues Sodium lauryl sulphate in isopropanol Pigments water wet v-TFD h-TFD

FIGURE 2. In this test, product was tested in both an h-PTFD and a batch paddle dryer. The difference was almost a factor of 500

Thin-film dryers are recommended for applications where low heating temperatures and reduced pressures plus high performance are needed. These include pharmaceuticals and polymers.

Drying intermediate pharmaceuticals


Drying intermediate pharmaceutical products is a quality-determining process step. In many occasions the production process of such products follows a batch mode. In the reaction stage of the process it is rather common to use solvents, occasionally also water, as the carrier phase. After crystallization of the intermediate product and mechanical separation of the liquid carrier phase from the solid intermediate, pharmaceutical drying is applied. Batch drying is typical for the pharmaceutical industry. It is often justified with arguments such as, better control of the temperature and better identification of the batches; the latter being imposed by good manufacturing practice (GMP) directive. The batch drying process is characterized by the following steps: Charge the wet filter or centrifuge cake into the dyer Evacuate the process chamber of the dryer to the desired operating pressure; if possible heat up the dryer at the operating temperature simultaneously Dry the charge to its final volatiles content Cool the dryer Discharge the final dry material from the dryer Clean the dryer from the residual material Condition the dryer for the next charge Beside the fact that batch drying demands long residence time (the actual process time), the total time required for the completion of one charge can be as long as 24 hours or even longer. Generally, the drawbacks of batch drying are: 1. Long residence time 2. High energy demand (heating and cooling cycles for each batch cycle) 3. Large drying equipment or a series of small equipment operating in parallel 4. High manpower demand (intensive handling) 5. Intermediate storage of batches is necessary A viable alternative for these applications is a horizontal thin-film dryer that is customized for pharmaceutical applications (h-PTFD), which offers the following advantages: High heat-transfer coefficient leading to high specific drying rates, even at low heating temperatures Extremely short product residence time in the process chamber of the dryer (< 5 min) under mild conditions These features also translate into small economic units. Comparing the product capacity resulting from a conventional batch paddle dryer with the one achieved in an h-PTFD, one can immediately appreciate and acknowledge the fundamental differences (see Figures 1 and 2).

Shear zone

calm film zone

bow wave zone

FIGURE 3. Since h-PTFDs offer perfect mixing, new possibilities for all-in-one processing, such as mixing and reacting open up with the positioning of rotating spray nozzles positioned along the axis of the rotor

FIGURE 4. By splitting the heating jacket into different heating zones and placing multiple feed nozzles along the axis of the dryer, an h-PTFD can maximize process control exibility

Compared to the paddle dryer, an h-PTFD has an extremely short product residence time and a high heat-transfer coefficient. The product residence times of a typical application that was processed in both dryers is shown in Figure 2. Shortening the product residence time up to a factor of 500 has the following effects: Reduction of side reactions Reduction of color changes Furthermore, with rapid and non-destructive drying h-PTFDs open up new possibilities for all-in-one processing. This can be accomplished, for instance, through the provision of rotating spray nozzles positioned along the axis of the rotor (Figure 3). Through such nozzles additional substances can be sprayed on the thin-film. Since this thin-film is extremely turbulent, a perfect mixing of the substances takes place. Therefore, an h-PTFD can allow simultaneous mixing and reaction processes in one single processor. Meanwhile, the maximization of the process control flexibility is achieved through splitting the heating jacket into different heating zones. Last but not least, additional feed nozzles can be placed at different places along the axis of the dryer (Figure 4).

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

41

Feature Report
TABLE 3: SELECTION CRITERIA ACCORDING TO THE VOLATILE COMPONENT CONTAINED IN THE FEED STREAM
Type of dryer Volatile component Water Solvent (low boiling point) Solvent (high boiling point) Vertical Horizontal Suitability

TABLE 4: SELECTION CRITERIA ACCORDING TO THE PRODUCT BEHAVIOR DURING DRYING


Type of dryer Vertical Horizontal Product behavior Suitability Crystallizes during drying Breaks up in particles Pasty phase during drying Sticky / viscous phase Crust forming on surfaces Temperature sensitive Softening at low temperature Melting at low temperature Combustible Dust explosion risk Toxic Abrasive = Suitable; = Conditional; = Not suitable

FIGURES 5 AND 6. Whether of vertical (above) or of horizontal design (below), a TFD consists of a cylindrical body with a heating jacket and a coaxial close-clearance rotor tted in the shell. The rotor is equipped with special elements (blades) and revolves at high speed

TABLE 5: SELECTION CRITERIA ACCORDING TO THE DESIRED FORM OF THE FINAL PRODUCT
Type of dryer Vertical Horizontal Desired form of final product Suitability Powder Fine crystals Coarse crystals Granular Paste Liquid or slurry = Suitable; = Conditional; = Not suitable

Background
Drying is a thermal-separation unit operation whereby, through heating, volatile substances are removed from a single non-volatile material or a mixture of several of them. The final product is relatively or completely free of volatiles. Its consistency can be that of a powder, a granular solid, a paste or even a concentrate of high viscosity. In the majority of industrial applications, the volatile substance is an organic solvent or water and occasionally a mixture of both. Concisely, dryers are classified according to how heat is transferred to the moist material in convective (direct contact), contact (indirect),
42

radiation or infrared, dielectric and freeze dryers. Thin-film drying technology falls into the category of contact agitated dryers and features the following: Low energy consumption Low space requirement High operational flexibility Safe processing of toxic and hazardous feedstocks Once-through process, without the need for recycling Ability to handle feedstocks of nearly any consistency Thin-film dryers are characterized by the following attributes: Gentle treatment of temperaturesensitive products

High heat-transfer rate Short residence time High number of stirred tanks Plug-flow Low product hold-up Continuous operation High turbulence in the thin product layer Environmentally friendly processing of toxic and hazardous substances due to completely closed design

Classification and selection


Tables 1 through 5 provide guidance toward the following: Classification of thin-film dryers, the mode and the range of their operation (Table 1)

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

VERTICAL TFD APPLICATION

he v-TFD is recommended for applications where a liquid feedstock under the effect of vaporization would FC M Sealing spontaneously crystallize. Spontaneous crystallization Exhaust system M Condenser means that no intermediate pasty phase would take place. PCR The case study described below demonstrates the advanFC M Cooling tages of the v-TFD. Feed medium In a specialty chemicals plant, product losses occurred with centrifugation method formerly used as part of purifiHeating Cooling v-TFD cation procedure in the manufacture of dimethyl sulfoxide. medium medium The process specifications required removal of a relatively small amount of inorganic salts from the product. The soHeating lution was to install a v-TFD for the processing step (see Condensate medium figure, right). N2 Normally, a solvent is evaporated and passes out the top of Vacuum the unit while powdered product is collected in the bottom. In the redesigned case, however, the product, dimethyl sulfoxide, is recovered from the top of the dryer and the powder Dry product in the bottom is the material removed. In operation, the feed material enters the top as slurry. A feed-specific distribution system spreads the feed material evenly over the circumference of product yield is enabling the equipment to pay for itself in a relathe thermal section. As the rotor turns and the blades wipe the shell tively short period of time. Maintenance has also been greatly improved, with at least several thousand dollars having been saved. of the unit, the drying process occurs in seconds. The result is that the improvement over the centrifugation method The system operates under vacuum, which along with the short has been dramatic. Product losses have been almost eliminated. residence time minimizes overheating and helps to maintain the Bottoms are in excess of 96% dry. Capital recovery from improved high quality of the dimethyl-sulfoxide solvent being recovered.

Turbulant zone

calm film zone

bow wave zone

FIGURE 3. In the thin ilm principle, a highly agitated bow wave is formed in front of the rotor blades. The turbulence increases as the product passes through the clearance before entering a calming zone situated behind the blades

Selection according to the consistency of the feedstock (Table 2) Selection criteria according to the volatile components contained in the feedstream (Table 3) Selection criteria according to the product behavior during drying (Table 4) Selection criteria according to the desired form of the final product (Table 5)

rotor is equipped with special elements (blades) and revolves at high speed. The blades are designed to evenly spread the material over the entire heated wall. This action forms a thin layer (film) over the heated wall, irrespective of the rheological consistency of the feed material, which is continually renewed and accompanied by intense turbulent flow conditions. The thickness of the layer is defined by the clearance between the rotor blades and the wall. A highly agitated bow wave is formed in front of the rotor blades (Figure 7). The turbulence increases as the product passes through the clearance before entering a calming zone situated behind the blades. As the product conveys along the heated wall, the volatile component evaporates continuously. The minimum clearance between the blades and the dryers wall (blades do not contact the heated wall) prevents fouling of the heating surface, minimizing the resistance to heat transfer, yielding rapid vaporization, promoting plug flow and granting the possibility to precisely control the product temperature.

Operating principle of TFDs Thin-film principle


Whether of vertical (Figure 5) or of horizontal design (Figure 6), a TFD consists of a cylindrical body with a heating jacket and a coaxial closeclearance rotor fitted in the shell. The Both horizontal and vertical types of dryers can be heated electrically, inductively or with steam, hot water or thermal oil. Vertical TFDs. Typically, the drying process in a vertical thin-film dryer (v-

TFD) comprises three distinct zones: the preheating, the slurry and the powder zone. In the preheating zone the product reaches its boiling temperature. Evaporation starts, supersaturation is reached and then solid particles begin to form. In the slurry zone, the concentration of solids increases. In this phase many products tend to form agglomerates, which are crushed under the action of the blades. In the powder zone the solid particles still contain volatile components, but they further vaporize until the drying process completes. For a given v-TFD, the length of each one of the three zones depends on the feedrate, the initial volatiles content and the operating conditions (predominantly pressure and heating temperature). Under steady operating conditions, if the feedrate to the dryer were to increase, the length of the preheating and the slurry zone would also increase. The same effect would happen, if at a constant feedrate the amount of contained volatiles would significantly increase. In either case, the result is that the powder zone decreases, which in turn leads to incompleted drying (higher final volatiles content). Nevertheless, for a well designed v-TFD system, fluctuations of the preheating and slurry zone can be compensated through the adjustment of the operating conditions. The vapors of the volatiles move through the dryer counter-current
43

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Feature Report
400 350

300 250 200 150 100 50 0

5 6 4 Froude number 86 151

Specific loading kg/h*m2

280

FIGURE 8. In a TFD, once the Froude number is higher than 1, the heat transfer coefficient stays practically constant. Similar measurements on a paddle dryer showed that constant heattransfer coefficients are not reached until the Froude number is at least higher than 4. In terms of energy, this means the paddle dryer must turn at a higher RPM with a larger electric motor, higher purchase expenditure and permanently higher operating cost to reach the same heat transfer coefficient as in the TFD

Heat transfer coefficient, W/m2K

1 2 3 4

kg/h 100 200 300 180

rpm 250 250 250 400

Frequency

1 3

100 200 300 Residence time, s

400

to the product flow and condense in an external condenser. As they flow through the dryer toward the vapor exit nozzle, any entrained fine particles re-agglomerate due to the contact with the wet feed. The final product from a v-TFD is usually a free flowing powder. However, other final product forms are possible, such as paste, slurry, melt and so on. The discharge of the final product from a v-TFD depends on its consistency and on the operating conditions. Specialized discharge systems are available. Horizontal TFDs. The horizontal TFD (h-TFD) is usually applied for drying pastes, such as filter or centrifuge cake feedstocks, slurries or crumbly materials. Pumps, screws or other feed devices supply the wet material to the dryer. The rotor is an endless screw. It is fitted with shovel-type blades to move the material, mixing blades to reduce the size of the lumps, and fixed clearance blades to maintain an even distribution while exposing every particle of product to the heating surface. The necessary residence time a parameter defined by the product characteristics or the process specifics or from both is controlled by adjusting the blades configuration of the rotor.

Froude number is the ratio of the centrifugal to the gravitational forces inside the unit. It is defined as follows: Fr = (2 n )2 r g

Comparing performance
Froude number. The performance of TFD can be compared with other agitated dryers by using heat transfer and the Froude number (Fr). The
44

(1) Where n = The number of revolutions of the rotor, 1/s r = radius of the rotor, m g = gravitational acceleration, m/s2 In TFD a proper Froude number is important because it ensures that the material covers the whole heating surface. This is accomplished when the centrifugal force is at least equal to the gravitational force. Figure 8 shows the dependence between U and Fr. The results were obtained with a reference free-flowing, dry material. From the figure, it becomes evident that once the Froude number is higher than 1, the heat transfer coefficient stays practically constant. Furthermore, it has been shown that the value of the heat transfer coefficient depends only on the specific loading of the TFD. Similar measurements on a paddle dryer showed that constant heat-transfer coefficients are not reached until the Froude number is at least higher than 4. In terms of energy, this means the paddle dryer must turn at a higher rotational speed with a larger electric motor, higher purchase expenditure and permanently higher operating cost to reach the same heat transfer coefficient as in the TFD.

FIGURE 9. In this graph of residence time distribution (for a reference material at various operating conditions), of particular importance is Run 4, which shows the mean residence time of 60 s at a speciic load of 195 kg/h-m2. This is a particularly narrow span for a solidshandling piece of equipment

Normally, heat transfer coefficients for free-flowing, dry granular materials in horizontal thin-film dryers are one order of magnitude higher, compared with conventional disc or paddle dryers. For the drying of filter cakes, slurries and very wet powders, TFD is particularly efficient, since Froude numbers greater than 1 can be used effectively. This is because the wet product in the dryer now behaves as a liquid, and accordingly reacts to turbulent conditions. As a result, there is more exposure to the heating wall, plus a greater break-up of the agglomerates as they are made. U-value. The overall heat transfer coefficient is defined as follows: U= Q A T

(2) Where U = Overall heat transfer coefficient, W/m2K Q = Total heat input into the unit, W A = dryer surface area, m2 T = Temperature difference between the heating medium and the boiling point of the volatiles, K Typical U-values in a TFD range from 350 to 750 W/m2K. The relatively high U-values indicate that high heat flux

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

HORIZONTAL TFD APPLICATION

complete h-TFD offers a closed, high-performance system. The figure, right, shows a h-TFD set up for the continuous vacuum drying of a pumpable press cake, which is temperature-sensitive. Briefly, the feed is metered into the unit, and drying occurs as the material is conveyed along the dryer length. The dried product is then discharged through an air lock at timed intervals. The volatiles are condensed and pumped back to the process. Once the dryer temperature and vacuum are established by standard control methods, the remaining operating variable becomes the feedrate, which is dependent only upon the material characteristics and solvent content. With the new drying-system, solvent worth several hundred thousand euros is being recovered on an annual basis. Short residence time of only a few minutes makes it possible to dry the heat-sensitive product at relatively high temperatures, while maintaining high quality. Since the system is completely closed, with no sweeping gas required, no loss of solvent occurs and there is no airborne dust. Hence, a potential air pollution problem has been eliminated. Product hold-up in dryer is less than 10 kg. Energy requirements are low, about 1.1 kg of steam per kg of water and solvent evaporated. Operating costs have been reduced due to the efficient use of energy and labor. Some care is needed in the operation. Close tolerance between rotor blades and wall requires occasional adjustment of rotor blades. The clearance is important for maintaining heat transfer and high throughput.

Cooling medium Filter Wet feed Cooling zone (optional) Condensate pump Vacuum pump

Feed pump

h-TFD

Drying zone Vacuum lock

Dry product

accompanies thin-film drying. The heat flux can be as high as 45 kW/m2, which is similar to a flash dryer. Due to high U-values and high heat fluxes, the residence time in TFD is short. For free-flowing solids the typical drying time is 45 s to 1 min. For viscous products, which can stick to the wall and agglomerate, it ranges from 3 to 5 min. While rotor speed does influence retention time to a degree, this method is not recommended for the regulation of the residence time. Instead, regulation is done by modifying the inner geometry of the rotor without sacrificing either heat transfer performance or materials handling capability. It is evident that product holdup in TFD is low, since just enough material is present to completely cover the heating wall in a thin layer. The product holdup depends on the consistency of the feedstock and its behavior during drying and is determined experimentally. This amount varies, depending on whether the feedstock is a free-flowing or pasty material or a filter cake.

small portion of the total feed, which stays long enough to become degraded, will contaminate the whole product. Owing to the rotor configuration of TFD, the feed pursues a helical path along the heated wall. Every particle of the feed follows in a strict sequence, thereby insuring that the treatment time is about the same for all portions of the feed. Figure 9 shows the residence time distribution of a reference material at various operating conditions. Of particular importance is Run 4, which shows the mean residence time of 60 s at a specific load of 195 kg/h-m2. This is a particularly narrow span for a solidshandling piece of equipment. Because of the three previouslymentioned factors (low holdup, short residence time and minimum back mixing), a TFD is scaled up with a high degree of assurance.

integrity on a case-by-case basis. Press cakes and slurries containing micro-size particles (1 to 5 microns) show a strong tendency to agglomerate and case-harden while drying. This is a natural phenomenon that fouls the heating surface of standard dryers. The elements of a TFD are designed to minimize the agglomerate buildup and to break up any agglomerates that have already been formed.

Concluding remarks
Adapting the thin-film principle to a rotary contact dryer offers the specialty chemicals, polymers, food and pharmaceutical industries a new dryer. Wet feedstocks irrespective of their consistency and hazardous behavior can now be continuously dried under product specific pressure and temperature at high drying rates and without a sweep gas. Edited by Rebekkah Marshall

Particle integrity
Another important advantage of the TFD is retaining particle integrity. It would appear that high shear forces set up by the rotational speed and the narrow clearance would damage the basic structure of free-flowing solids. However, this is negligible as demonstrated from numerous experimental results. It has been proven that crystalline or even amorphous materials exhibit a marginal decrease of their particle size mainly due to abrasion of the edges rather than due to disintegration. For extremely shear-sensitive particles, such as pigments, it is recommended to investigate the particle

Author
Georgios Raouzeos is manager of process and engineering at Buss-SMS-Canzler GmbH, Branch Office Pratteln (10 Hohenrain Str., Pratteln, CH-4133, Switzerland: Phone: +41 61 825 66 32; Fax: +41 61 825 67 66; Email: georgios.raouzeos@sms-vt. com). He has been a professional engineer since 1985, focused on the design of specialized contact-drying industrial systems and of specialized units for the thermal treatment of polymers. He holds a B.S.Ch.E. from University College London (U.K.), and a Ph.D. in chemical engineering from the National Technical University of Athens (Greece). During his professional career, his research interests focused on the development and optimization of specialized dryers and reactors, the latter especially for the synthesis and refining of polymers.

Residence time distribution


In trying to prevent product degradation, it is of no use to secure a short mean residence time for the product in the heated zone if at the same time the residence time distribution is bad. A bad distribution of residence time means that although some of the feed goes through in less than the mean time, a certain portion will stay much longer than the mean time. Even a

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

45

Feature Report Engineering Practice

Cooling Water Outlet Temperature:


Hot t2
1

T1

Exchanger EVALUATING THE BEST MAXIMUM VALUE Cooling tower This article discusses the evaluation Air T t process and tradeoffs Cold that must be considered to optimize FIGURE 1. The components of a typical recirculatingcooling-water system are shown here with the various recirculating cooling-water systems inlet and outlet streams labeled
2

Alejandro Anaya Durand, National University of Mexico Ricardo Gabriel Surez Surez, PEMEX Francisco Javier Pacheco Romn, Mexican Petroleum Institute (IMP) Adriana Shunashi Garca Cornejo, Mexican Petroleum Institute (IMP) Luis Francisco Villalobos Vazquez de la Parra King Abdullah University of Science and Technology (KAUST)
ecirculating cooling-water systems are essential parts of many facilities throughout the chemical process industries (CPI), including petroleum refineries, petrochemical, chemical and nuclear plants, and others. The cooling system shown in Figure 1 is widely used as a safe method for removing heat from various process operations. Typically, the process engineer uses rules of thumb to define the cooling water flowrate, the temperature of the cooling-water return stream to the tower (t2) and the inlet temperature of the cooling water stream to the heat exchanger (t1) [1]. These criteria can be used to obtain quick and reliable estimates, and to optimize both system design and operation. The temperature of the coolingwater return stream to the tower has a direct impact on the water flowrate and the required surface area for the
46

heat exchange equipment. On one hand, for a determined inlet temperature of the cooling water stream to the heat exchanger (t1), the use of a higher temperature of the coolingwater return stream to the tower (t2) can help to decrease the quantity of cooling water that is required. Consequently, the TLMTD value calculated by the heat exchanger design equation [shown below as Equation (2)] decreases and the heat-transfer surface area thus increases (thereby increasing a fixed cost of the system). But this tradeoff is often worthwhile, since the cooling-water pumping costs (an operational cost) also decrease as a result of the reduced water requirements. Efforts to achieve an economic balance between the temperature, the cooling water flowrate, and the required heat exchanger area indicate that the optimal temperature of the cooling-water return stream to the tower (t2) occurs at the point of minimum total cost for cooling water and equipment fixed charges. The purpose of this article is to show that selecting a higher temperature for the return stream to the cooling tower can often be justified, when one considers the impact of higher operational costs (in terms of energy and cooling water) in comparison to the fixed costs related to increased heat exchanger size. Meanwhile, since scale formation is a common issue in cooling tower

systems, this article also discusses how to use the Ryznar Stability Index (RSI) to provide another evaluation of the selected water temperature. The RSI gives a qualitative value of the waters tendency to form scale. Thus, an RSI evaluation guarantees the correct operability of the system with the derived optimumreturn temperature. By using the calculated RSI value, the designer or process engineer can decide whether the calculated optimum return temperature should be used, based on the actual scale-forming tendencies of the water.

The basic equations


The procedure described below can help users to find the optimum temperature for the return stream to the cooling tower (t2). It is based on the method described by Peters [2]. The energy balance in any heat exchanger system is given by Equation (1): Q =wCp(T2 T1 ) Considering the design equation: Q = UAFG LMTD heat (1) exchanger

(2) Where the LMTD is defined using Equation (3): LMTD = (T1 t 2 ) (T2 t1 ) T t ln( 1 2 ) T2 t1

(3) Working out the value of w from Equation (1):

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

290 270 250 230

Solution of Equation (9) to find the optimum exit temperature t2 at the minimum total costs for ordinary range of Z

Z = (T1-T2)/(T2-t1) 8 10 12 14 16 20 22 24 28 32 18 26 30

Y0 =

(T2 t1 )

(T1 t 2 )

(10)

Y0 = (T1-t2) / (T2-t1)

210 190 170 150 130 110 90 70 50 30

UF C H X0 = G W Y C A K F CP Z=

(11)

(T1 T2 ) (T2 t1 )

(12)

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 X0 = (UFGCWHY)/(CAKFCP)

Calculation of the desired (T1t2) values is achieved using a numeric method. But the numeric method can be avoided by using the chart shown in Figure 2.

An example
The goal of this example is to design a counterflow cooling tower to cool 10,000 lb/h of gas, having a Cp of 0.24 Btu/lb, from 200 to 90F, using water that enters the cooling tower at 85F. To do this, we follow the steps described below, to calculate the optimum temperature for the return stream to the cooling tower (t2) for the year 1990 and 2011. For this example, it is assumed that the overall heat-transfer coefficient at the optimum conditions may be taken as 7.8 Btu/(h)(ft2)(F). The heat exchanger is to operate 8,400 h/ yr, and the heat exchanger has a single shell pass and a single tube pass (1-1). Thus, it has a geometrical factor of 1 (Note: This measure depends on the geometrical arrangement of the shell and tube passes in the exchanger and serves as a correction factor that must be used with the log mean temperature difference for a countercurrent heat exchanger to accommodate the fact that the flow of two streams is more complicated than simple countercurrent or concurrent flow. The value of this factor can be obtained from graphs or equations typically reported in the literature). The rest of the required parameters are provided in Table 1. Before carrying out the direct calculation of the optimum temperature for the return stream to the cooling tower (t2) using Equation (9), some values that are required as inputs to this equation must be calculated. The procedure for obtaining these values, which are the parameters from Table 1, is briefly explained next.
47

FIGURE 2. This igure shows the solution of Equation (9) for an ordinary range of Z. With the given known data, X0 and Z are calculated using Equations (11) and (12), respectively. Then, the value of Y0 can be read from this chart, and with this value, the desired value (t2) can be obtained, using Equation (10)

TABLE 1. KEY PARAMETERS USED FOR THE EXAMPLE


Economic information Cooling water costs, $/lb Cost per square foot of heat transfer surface, $/ft2 Chemical Engineering Plant Cost Index (CEPCI)3 19901 1.81x10-5 32.2 357.6 Year 20062 Not calculated 45.0 499.6 2011 3.63x10-5 53.0 588.9

1. The year 1990 was chosen to provide a representative range of time against which the current data could be compared. 2. The year 2006 was used as a reference to obtain the 1990 and 2011 values of the cost per square foot of heat transfer surface material. The price for year 2006 is an average price for a shell-andtube heat exchanger type based on all-stainless-steel construction and may vary depending on the manufacturer [3]. 3. Evaluated monthly by the staff of Chemical Engineering and printed along with historical values of this and other indexes on the last page of each issue.

w=

(4) the annual cost for cooling water is QHyCw. From Equation (4), the operational cost (including the costs of the cooling water and pumping) is expressed using Equation (5): CO = QH yCw Cp(t 2 t1 )

Q Cp(T2 T1 )

T1 t 2 ) T2 t1 CT = + Cp(t 2 t1 ) UFG [ (T1 t 2 ) (T2 t1 )] QH yCw K F C AQ ln( (8) Equation (8) contains the desired variable, which is the temperature of cooling water leaving the heat exchanger (t2). Then, the corresponding optimum exit temperature can be found by differentiating Equation (8) which reflects the annual sum of water costs and fixed charges with respect to t2, or more simply, with respect to the temperature difference (T1t2), and setting the result equal to zero to find the minimum total annual costs. When this is done, Equation (9) is obtained: X0 = ( Z + 1 Y0 2 1 Y0 )( + ln Y0 ) Y0 1 Y0

(5) The fixed costs, which depend on the heat exchanger size, are calculated using Equation (6): (6) Then, by combining the foregoing relations, the total annual cost is expressed according to Equation (7): CT = QH yCw Cp(t 2 t1 ) + AK F C A CF = AK F C A

(7) Substituting the area (A) from Equation (2):

(9)

Wherein:

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

16

Engineering Practice
Ryznar stability index (RSI)

15 14 13 12 11 10 9 8 7 6 5 4 50 60 70 80 90 100 110 120 130 140 150 160 170 180

Cost per square foot of heat-transfer surface material. The costs per square foot of heat transfer surface for 1990 and 2011 were determined, using the Chemical Engineering Plant Cost Index (CEPCI), as shown in Table 1 from the known cost for the year 2006 [3]. The results are shown in Table 1. The calculation is carried out using Equation (13):
CE PCI Value in year A Cost in year A = CE PCI Value in year B cos t in year B

Temperature, F Lake water (very soft) Borehole water (hard) River water (slightly hard) Ground water (very hard)

(13) (CEPCI data is available at www.che. com/pci) For the year 1990: Cost in 1990 =

River water (moderately hard) Surface water (moderately soft)

( 357.6 ) 45 = 32.2 ( ) ( 499.6 ) ( 588.9 ) 45 = 53.0 ( ) ( 499.6 )

FIGURE 3. This plot shows the Ryznar Stability Index (RSI) data versus temperature for different types of water

TABLE 2. PARAMETER VALUES FOR WATER COST CALCULATION


Price of energy for industry in U.S. $/GJ4 Chemical Engineering Plant Cost Index (CEPCI) Cooling water cost coefficient, a (Grassroots plant with q = 10 m3/s, $/m3) Cooling water cost coefficient, b (Grassroots plant), $/m3 1990 2011 1990 2011 5.07 13.19 357.6 556.8

For the year 2011: Cost in 2011 =

Cooling-water costs. The cooling water cost was calculated using Equation (14), which was obtained from Ref. 4: CS ,u = a ( CEPCI ) + b CS , f

0.0000725 0.003

4Calculated with a weighted average of the most common fuels used in U.S. Data obtained from the May 2011 Monthly Energy Review published by the U.S. Energy Information Administration

(14) For year 1990: tained that: Y0 = 15.7 =


5

Table 2 shows the values of the parameters required for Equation (14). The cooling water costs for year 1990 and 2011 were obtained by substituting the values from Table 2 into Equation (14). For year 1990: CS ,u = 0.0000725 ( 357.6 ) + 0.003( 5.07 ) CS ,u = 0.04 $ m 3 = 1.81 10 5 $ / lb For year 2011: CS ,u = 0.0000725 ( 556.8 ) + 0.003(13.19 ) CS ,u = 0.08 $ m 3 = 3.63 10 5 $ / lb Optimum outlet temperature of the water. Finally, once the cost per square foot of heat- transfer surface and the cooling water costs are calculated, these values are substituted in the Equation (9) for both years:
48

X0 =

( 7.8 )(1) (1.81 10 )( 8400 ) = 0.37 ( 32.2 )( 0.1)(1)

UFG CW H Y = C A K F CP

( 200 t2 )
5

Thus, t 2 = 121.5 F From the calculations, it is observed that in 11 years the optimum temperature has increased by 2.5F. This increase is justified for the rise in energy cost over that time period.

(T T2 ) = ( 200 90 ) = 22 Z= 1 (T2 t1 ) ( 90 85 )
It is obtained from Figure 2 that: ( 200 t2 ) Y0 = 16.2 = 5 Thus, t2=119F. For the updated values, year 2011: X0 = UFG CW H Y = C A K F CP

Ryznar Stability Index


Once the optimum temperature has been calculated, users should critically evaluate the use of this particular temperature using the RSI scale index, as mentioned earlier. This reevaluation allows the user to know if at the calculated optimum temperature the likelihood for scale problems in the cooling water system rises (thereby creating potential problems and additional costs). As noted, for a given inlet water, the tendency for a given system to form

( 7.8 )(1) ( 3.62 10 5 )( 8400 ) = 0.45 ( 53.04 )( 0.1)(1)


Z=

(T1 T2 ) = ( 200 90 ) = 22 (T2 t1 ) ( 90 85 )

Once again, from Figure 2, it is obCHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

NOMENCLATURE
Exchanged heat, Btu Flowrate of the cooling water, lb/h Heat capacity, Btu/(lb)(F) Constant overall coefficient of heattransfer determined at optimum conditions, Btu/(h) (ft2)(F) A Area of heat transfer, ft2 FG Geometrical factor (depends on the geometrical arrangement of the shelland-tube passes in the exchanger), dimensionless LMTD Log mean temperature difference driving force over heat exchanger, F T1 Temperature of the hot process stream entering the heat exchanger, F T2 Temperature of the hot process stream leaving the heat exchanger, F t1 Temperature of cooling water entering the heat exchanger, F Q w Cp U t2 Temperature of cooling water leaving the heat exchanger or temperature of the cooling water return stream to the tower, F Operational cost, $/yr Hours the exchanger is operated per year, h/yr Cooling water cost assumed as directly proportional to amount of water supplied, $/lb Annual fixed costs, $/yr Annual fixed charges including maintenance, expressed as a fraction of initial cost for completely installed equipment, dimensionless Installed cost of heat exchanger per square foot of heat-transfer area, $/ ft2 Total annual costs, $/yr Cooling water price for use in Equation (14), $/m3 Fuel price for use in equation (14), $/GJ CEPCI Chemical Engineering Plant Cost Index, which is an inflation parameter for projects in the U.S.5 Cooling water cost coefficient, $/m3 a Cooling water cost coefficient, $/m3 b q Total water capacity, m3/s RSI Ryznar Stability Index, dimensionless pH pH value of studied water T Water temperature, F pHS pH value of water saturated in CaCO3 S Coefficient of the equation to calculate pHS, dimensionless t Coefficient of the equation to calculate pHS, dimensionless D Coefficient of the equation to calculate pHS, dimensionless B Coefficient of the equation to calculate pHS, dimensionless TDS Total dissolved solids, mg/L TH Total hardness as Ca2+, mg/L TAlkalinity Total alkalinity, mg/L

CO Hy Cw CF KF

CA CT CS,u CS,f

5. Calculated with a weighted average of the most common fuels used in the U.S. data obtained from the May 2011 Monthly Energy Review published by the U.S. Energy Information Administration

TABLE 3.TYPICAL WATER ANALYSIS, PPM


Parameter Lake water (VS) 6.3 2 10 33 Surface water (MS) 6.8 38 53 88
SH: Slightly hard

River water (SH) 7.4 90 120 185

River water (MH) 7.5 180 230 332

Borehole water (H) 7.1 250 340 400


H: Hard

Ground water (VH) 7.1 470 559 1,670

pH Total alkalinity Total hardness Total dissolved solids


VS: Very soft

MS: Moderately soft

MH: Moderately hard

VH: Very hard

calcium carbonate scale can be predicted from calculations involving calcium hardness, total alkalinity, total dissolved solids, pH and temperature. The most commonly used indicators are the Langelier Saturation Index (LSI), the Ryznar Stability Index (RSI), and the Puckorius (Practical, Predictive) Scale Index (PSI) [5]. For this article, the RSI was chosen to predict the scale tendencies. The RSI has several advantages over the other techniques: it always gives positive values, provides better estimates of the severity of scaling tendencies [6], and it is not possible for low-hardness and high-hardness waters to have the same value (which can sometimes happen with the LSI [7]). RSI is defined by Equation (15) [8]: RSI = 2 pH s pH (15) Usually, pHs is calculated by the following relation [8]: pH s = 9.3 + S + t D B Where: S = 0.1( log (TDS ) 1) (17) (16)

T + 459.67 t = 13.12 log + 34.55 1.8 (18) D = log (TH ) .04 B = log TAlkalinity

(19) (20)

Some typical values corresponding to different types of water for calculating the parameters S, D and B are shown in Table 3 [9]. For practical purposes, the RSI was calculated considering a wide range of temperatures and the values of the parameters shown in Table 3 for all types of water. The results are presented as a graph in Figure 3. This graph helps one to easily determine the RSI, given a particular type of water and a cooling water temperature. Using the optimum temperatures obtained from the example for year 1990 and year 2011, and considering river water (slightly hard), RSI can be determined easily from Figure 3. For year 1990 and t2 = 119F, the value of RSI according to the graph is 7.5. From Table 4, it is found that with

this RSI value, scale may be dissolved. It is suggested to use the value of 7 > RSI > 6 as a breaking point, instead of using the published value of RSI = 6. Now for year 2011, where the temperature to evaluate for scale-forming tendency is higher, the following exercise analyzes also the effect of the type of water on the RSI value. The results of evaluating the RSI for all types of water, considering t2 = 121.5F, are shown in Table 5. As it can be observed, the optimum temperature obtained for year 2011 is higher than that for year 1990. For both years, comparing the results of the RSI obtained for the same type of water (river water, slightly hard), this temperature increase gives a lower RSI value (7.4). In this case, given the characteristics of the water, scale also may be dissolved, but the RSI value tends to be in the limit of being in chemical balance. For the same example, and considering the case of borehole water that is relatively hard, this increase on the temperature of the cooling water return stream to the tower (t2) is even more convenient, because, according to Table 4, the RSI (6.0) shows that the system is in chemical balance thus, the water is essentially neutral. Hence, operating with a higher cooling water outlet temperature is justified and should provide no additional problems in terms of added scale. Readers should note that the RSI relates only to scaling not to corro49

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Engineering Practice
TABLE 4. CALCIUM CARBONATE SCALING TENDENCIES
Properties Scale may be dissolved RSI 6 Generally in chemical balance Scale may form and precipitate RSI Value > 8.5 >7.5 7.0 6.0 5.0 < 4.5 Interpretation Aggressive scale removal Scale removal expected Essentially neutral. Mild scale formation or removal possible Scale formation anticipated

Authors
Alejandro Anaya Durand (Parque Espaa No. 15b Col. Condesa, C.P. 06140, Mexico, D.F. Phone +52-55035898; Email: aanayadurand@hotmail .com), holds a B.S.Ch.E from the National University of Mexico (UNAM), and an M.S. degree in project engineering from UNAM. He has 48 years of experience in project and process engineering. He retired from Instituto Mexicano del Petroleo in 1998, after holding several top positions. Durand now consults to several engineering companies. He has published more than 250 papers related to engineering and education, and has served as an educator in chemical engineering at several universities throughout Mexico. Durand is a Fellow of the AIChE, a member of Mexicos National Academy of Engineering, and has received many awards in chemical engineering in Mexico. Ricardo Gabriel Surez Surez (Industria #6 Col. Florida Axotla, C.P. 01030, Mxico D.F.; Email: [email protected]) holds a B.S.Ch.E. from the National University of Mexico (UNAM), graduating with honors. He currently works for PEMEX Exploracin y Produccin (PEP) in the technology-monitoring project for the oil & gas industry. Francisco Javier Pacheco Romn (Av. Universidad #2014 Ed. Argentina 503 Col. Copilco, C.P. 04350, Mxico D.F.; Email: francisco. [email protected]) holds a B.S.Ch.E. from the National University of Mexico (UNAM). He graduated with honors. He has professional experience in environmental regulations and has worked as a consultant for the Minister of Environment and Natural Resources of Mexico (SEMARNAT). Currently he works for the Mexican Petroleum Institute (IMP) in the technology-monitoring project for the oil & gas industry. Adriana Shunashi Garca Cornejo (Hidalgo No 5-A, Colonia Axotla, Alvaro Obregn , C.P 01030 , Mxico, D.F., Mxico; Phone: +52 55 18 70 76 40; Email:adrianashunashi. [email protected]) holds a B.S.Ch.E. from the National University of Mexico (UNAM). She graduated with honors. She worked as a trainee in COMEX Mexico. Currently she works for the Mexican Petroleum Institute (IMP) monitoring project for the oil and gas industry. Luis Francisco Villalobos Vazquez de la Parra (Rincon de los Arcos 95, Col. Bosque Residencial del Sur, C.P. 16010, Xochimilco, Mexico, D.F; Phone: 52 55 29 09 52 02; Email: luisfranciscovillalobos@ gmail.com) is studying a masters degree at the King Abdullah University of Science and Technology (KAUST). He holds a B.S.Ch.E. from the National University of Mexico (UNAM). He worked as a trainee in DuPont Mexico.

TABLE 5. RSI VALUES FOR DIFFERENT TYPES OF WATER USING THE 2011 OPTIMUM TEMPERATURE FROM THE EXAMPLE
Lake water (VS) 13.9 Surface water (MS) 9.4 River water (SH) 7.4 River water (MH) 6.2 Borehole water (H) 6.0 Ground water (VH) 5.2

RSI

VS: Very soft MS: Moderately soft SH: Slightly hard MH: Moderately Hard H: Hard VH: Very hard

sivity even though these two troublesome conditions are often loosely correlated. The RSI and other indicators were never intended as measures of corrosive tendencies towards mild steel or other metals. They describe only the waters corrosivity towards an existing calcium carbonate scale [5]. From this exercise, one can see that the optimum tower-inlet temperature increase is justified for the rise in energy cost, but this increase may result in higher scaling problems. To avoid scaling, the temperature may need to be decreased, or the scale problem may need to be managed through the use of additives. One should carry out a cost-benefit analysis for the use of anti-scale additives, to compare with the costs of decreasing temperature.

Final thoughts
With rising energy costs, the prospect of increasing costs for cooling water pumping makes it more attractive to select a higher optimum temperature of the cooling-water return stream to the tower (t2). This tradeoff may mod-

ify the current rules of thumb used for selecting the temperature. According to the example presented in the article, the cooling-tower return temperature should be 121.5F. This is 1.25% higher than the temperature recommended using the existing rules of thumb, which suggested using a temperature of 120F [1]. However, further analysis of the optimum temperature found that, with the given conditions, the water may have a slightly scale-dissolving tendency. Not only does this depend on the water temperature, but also on its chemical characteristics. The RSI calculation for a wide range of critical parameters, such as the pH and the temperature, provides a panoramic view of the impact for different operation conditions. If water has a scale-formation tendency at the optimum temperature, then lowering this temperature or adding an anti-scale additive should be considered for the most cost-effective tower performance. Edited by Suzanne Shelley
5. Cavano, R.R., Understanding Scaling Indices and Calculating Inhibitor Dosages, NACE International, 2005. 6. Ryznar, J.W., A new index for determining amount of calcium carbonate scale formed by water, Journal AWWA, Vol. 36 p. 472, 1944. 7. Ryznar, J.W, An index for determining the amount of calcium carbonate scale formed by a water, Journal AWWA. 8. Moraru, M., Cameni, I., and Chiopescu, A.,The Characterization of Cooling Waters by Using Stability Indexes, Romanian: Petroleum Gas University of Ploiesti, 2010. 9. Roberge, P.R. Handbook of Corrosion Engineering, McGraw-Hill, New York, 2000. 10. U.S. Energy Information Administration, Monthly Energy Review, May 2011.

References
1. Coker, A.K. and Ludwig, E.E., Ludwigs Applied Process Design for Chemical and Petrochemical Plants, Gulf Professional Publishing, U.S., 1995. 2. Peter, M., and Timmerhaus, K., Plant Design and Economics for Chemical Engineers, McGraw Hill, New York, 1958. 3. Ferraro, A., Process Heating For Manufacturing Engineers Who Use Heat Processing Equipment and Supplies, in Heat Exchanger Basics, 2006. Retrieved November 17, 2011, from http://www.process-heating.com/Articles/Feature_Article/8a3a404a85ca9010Vg nVCM100000f932a8c0 4. Ulrich, G.D., and Vasudevan, P.T., How to Estimate Utility Costs, Chem. Eng., Vol. 133 pp. 6669, April 2006.

50

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Feature Report Engineering Practice

Reciprocating Compressors Startup and Capacity Control Methods


Procedures and guidelines that will help operators minimize energy consumption and maintenance requirements of compressor systems
Ali Ghanbariannaeeni Nargan Engineers and Constructors Ghazalehsadat Ghazanfarihashemi Sazeh Consultants
here are two main reasons why compressor capacity regulation is used. The most prevalent reason is to adjust the suction flow to match the process demand. The second reason is to save energy. As a rule, capacity control is determined by the compressor discharge pressure. Compressor capacity-control methods are utilized to maintain a required delivery under variable process conditions [1]. In this article, methods for controlling the capacity of reciprocating compressors are presented in detail. These methods are bypass recycling, unloader valves, clearance pockets, stepless valves and variable-speed drives. The advantages and disadvantages of each method, as well as their applications, are presented. In addition, auxiliary devices and packages used under transient conditions (namely, during startup, shutdown and maintenance) and during normal operation are described. Barring devices (gear), hydro-jacking systems, frame lubrication systems and cylinder lube oil systems are explained. Finally, a recommended procedure for starting up and stopping a reciprocating compressor in single and parallel operation is presented, along with some major points that should be taken into consideration by plant operators. pass can be used. Because of decreasing discharge pressure, the absolute power input would be reduced in this way, although the mass flowrate is increased as shown in Equations (1) and (2). (1)

Capacity control methods


Bypass control. As the name implies, this control method uses an external bypass around the compressor to recycle gas from the compressor discharge to the inlet, or to the atmosphere in the case of an air compressor. The take-off point for the bypass must be downstream of a heat exchanger so that cooled gas will be spilled back to the suction. If there is no exchanger in the discharge, the bypass must branch into the suction line upstream of an exchanger. Alternatively, a cooler may be placed in the bypass line. In any case, the bypass should tie-in upstream of a suction knockout drum so that any condensate resulting from the expansion cannot enter the compressor. Bypass control is preferred over other control methods because of its smoothness, simplicity and low initial costs. It is, however, inefficient because excess compressor capacity is expanded across the control valve in the recycle line. For this reason, this method is commonly accompanied by the use of inlet valve unloaders or clearance pockets, which reduce compressor capacity in discrete predetermined steps [15]. In multistage compressors, a bypass around the first stage or a partial by(2) Where: W = m = Mw = p2/p1 = K = Tin = PD =

Compressor power Rated mass flow Gas molecular weight Compressor ratio Gas specific-heat ratio Gas inlet temperature Compressor piston displacement Q = Compressor flow C = Compressor clearance volume R = Ideal gas constant It must be remembered that a reduction in the flow to the second stage causes a drop of all inter-stage pressures, and consequently it can lead to excessively high-pressure ratios and discharge temperatures in subsequent stages. Moreover, this pressure shifting may cause an overload in the last stage. Thus, there should be a limitation on the maximum by-passed flow in multistage equipment. The minimum capacity that can be obtained depends on the number of compression stages. The more stages used for a given overall compression ratio, the wider the achievable control range. Inlet valve unloaders. Valve unload51

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Engineering Practice
ers are mechanisms that are held open or bypass one or more cylinders inlet valves at each end of double-acting cylinders. This provides complete unloading of one or both ends of the cylinder. For a single-cylinder compressor stage, valve unloaders can achieve three-step unloading that provides nominal cylinder capacities of 100, 50 and 0%; and two-step unloading that provides cylinder capacities of 100 and 0%. Thus, considering two cylinders per compressor, the capacity can be controlled in five stages 100, 75, 50, 25 and 0%. Three-step (100, 50 and 0%) capacity control is used on some general purpose machines, such as air compressors. This method of control requires more cyclic actuation of the unloaders than five-step control. Therefore, three-step control is more detrimental to machine components especially to valves. Standard API 618 [6] introduces three unloader types: finger, plug and port. The finger type unloader is not recommended when other types are viable. Plug type unloaders should be installed on extra suction ports. A minimum number of valve unloader steps should be considered in order to maximize compressor reliability. Unloaders should be pneumatically operated by instrument air and equipped with positioner indication. The unloader actuator should be sized to operate on minimum air pressure as well. Nitrogen purge ports should be provided for all types. The unloader stem packing should be provided with a lantern ring and a nitrogen connection for the purging of leak gas. All purge and vent connections should be piped up to a single purge and vent connection. All lines to and from unloaders are to be AISI 316 L stainless steel [6, 7]. It should be noted that there are some restrictions on actuator sizing at suction pressures higher than 70 barg. Clearance pockets. Cylinder delivered capacity can be reduced by increasing the cylinder clearance volume; this is done by a clearance pocket. There are two types of pockets: fixed and variable. Opening the pocket reduces the cylinders inlet volumetric flow by trapping additional gas in the
52

larger clearance volume at the end of the piston stroke. Consequently, clearance-pocket flow adjustment is frequently applied to the head end only, leading to a maximum of 5060% reduction in the head end capacity and a 2530% overall capacity reduction in a double acting cylinder [8]. Valve unloaders combined with clearance pockets can provide fivestep unloading leading to nominal cylinder capacities of 100, 75, 50, 25 and 0% in a compressor with only one cylinder. This means that 75% capacity is achieved by opening the head-end clearance pocket, 50% load makes use of the crank-end valve unloader, 25% load makes use of the crank-end valve unloader and head-end clearance pocket simultaneously and 0% load is achieved by activating the valve unloaders on both ends of the cylinder. At compression ratios below 1.7, the pocket volume becomes very large relative to cylinder size, thus, it should not be used in this case [2]. Clearance pockets can be arranged for local manual operation, manual/ pneumatic operation, or automatic/ pneumatic operation. However, the automatic/pneumatic type is preferred. Using clearance pockets is usually restricted to services with cylinder inlet pressures less than 70 barg. Stepless capacity control. A stepless capacity control system, known as reverse flow control, can provide a capacity range of approximately 100 to 40% of rated capacity; however, more turndown ratios have become feasible recently. In this system, an unloading device is fitted to each suction valve. At partial loads, the unloading device does not allow the inlet valve to close when the piston is at its bottom dead center position, but rather delays the closing in a controlled way. Consequently, an amount of gas, which can be adjusted, is allowed to return to the compressor inlet manifold before the compression starts. As the piston velocity increases in the compression stroke, it pushes gas in reverse flow back out the inlet valve faster and faster. This creates a larger and larger gas drag force on the inlet valve plate that eventually overcomes the unloader force and closes the inlet valve. Applying this type of control requires

economic justification. In general it is not recommended because of limitations in performance accuracy and fatigue consequences on the valve plate and seat [7]. Inlet throttling. This method of capacity control is not recommended because pressures lower than normal inlet pressures cause higher pistonrod loads and discharge temperatures. Consequently, the mass flow range that can be safely achieved in this regard is normally too low to suit process needs. Variable speed drive. Reciprocating compressors should normally be specified for constant-speed operation in order to avoid excitation of torsional, acoustic and mechanical resonances. When variable-speed drivers are used, all equipment should be designed to run safely throughout the operating speed range, up to and including the trip speed [6]. Gas engine drives, which could operate in a 75 to 100% speed range, make use of variable speed method for flow control. Operation below 75% is normally done by bypass control and inlet valve unloaders or clearance pockets [912]. Startup unloading. Some means of unloading for startup is usually required because drivers lack sufficient torque to accelerate the train rotating parts under positive displacement compression loads. Inlet valve unloaders and external bypasses are the two most commonly used methods for startup unloading. The machine should be capable of starting with operating suction pressure on each stage. An unloading system may be designed to operate automatically on a voltage dip for service continuity where automatic reacceleration of motor driven compressors is required.

Compressor operation modes


Auto mode. In the automatic (auto) mode of operation, the compressor meets the demand of all the main processes, including all cases of operation requested by the equipment datasheet. In some cases, operation with nitrogen is also requested for pre-commissioning, cleaning purposes, testing of the automatic functions and leak testing of other equipment. In this mode, the machine is controlled automatically.

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

When the compression gas is changed, set point values are only adjusted for the new condition with no change in control procedure. Maintenance mode. In this mode, during which the compressor is at standstill, all auxiliary drivers (such as auxilliary oil pump, water pumps, and bypass valves) can be manually started by operators. Off mode. In this mode, all drivers are out of operation, and standby functions are disabled. This mode will be activated only when the compressor is not running; otherwise, selecting the off mode will have no effect on the operation of the compressor. Mode selection between auto, off and maintenance is done within the distributed control system (DCS). A compressor is provided with several local instrument boards (LIBs), with gages for indicating pressure, temperature, flowrate and level of process gas, lubrication oil and other utilities (such as water, air and nitrogen), during compressor operation in all modes. Additionally, the LIB shows whether local motor-control stations are also available for local starting and stopping of auxiliary equipment in maintenance mode. Auxiliary motors also have local motor-control stations located within a few meters from the associated auxiliary-drive motor. Visualization and control of the compressor operation is normally done from a central control room (CCR) station.

Compressor auxiliary systems


Hydro jacking device. For large reciprocating compressors and motors, manufacturers consider adding an additional system to the equipment in order to lessen the breakaway torque in the bearings in transient conditions (startup, shutdown or maintenance). For this purpose, one oil pump is usually added in series after the lubrication pump. A jacking oil pump assures lasting oil film existence between bearing and journal (shaft) surfaces at the instant a rotation commences. Barring device. The compressor should be fitted with a barring device (barring gear), which can be manual, electrical or pneumatic. This device is used only for maintenance, while the compressor is stopped. For compres-

sors with a rated power equal to or greater than 750 kW (1,000 hp), and torque requirement equal to or greater than 1,600 Nm (1,200 ft-lb), either the electrical or pneumatic type should be considered. Manual barring may be achieved by turning the flywheel. The barring device should be designed so that gas forces acting on the pistons cannot cause the compressor either to accelerate or to rotate in the reverse direction. With the barring device engaged, it should not be possible to start the compressor [6]. Manual barring devices should have a locking feature, whereas pneumatic and electrical devices should incorporate appropriate safety switches or measures for interlocking with the main driver. Moreover, a pneumatic system should be equipped with an air-supply inlet filter and oiler, and a four-way control valve for operation in forward or reverse directions. The barring device should be designed to enable barring over the pressurized machine at suction pressure. Before the barring device is enabled to start, the hydro jacking of compressor and main motor have to be started, and the minimum pressure must be obtained. The barring device operates with a local push button (forward and reverse) on the local panel near the motor. The barring device motor works only while one of the push buttons is pressed; release of the button stops the barring device and locks the crank gear. When maintenance is finished, the stopped barring gear must be moved back in the turn wheel free position, which is displayed on the DCS system. Compressor frame lubrication system. A frame lubrication system is pressurized through two electrically driven oil pumps. One is used for normal operation (main pump) and the second is in standby mode as an auxiliary pump for necessary conditions. A crankshaft-driven main pump is allowed per API 618, but for large machines, each oil pump should be individually equipped with an electrical motor. In auto mode, the main oil pump has to be started before starting the compressor main motor. Generally, pre-lubrication time is set for approxi-

mately one minute. When pre-lubrication time has passed, the startup condition Pre-lubrication time passed is activated and displayed on the DCS. When neither the low-lube-oil pressure alarm nor the low low-lube-oil pressure alarm is activated, the hydro jacking pump and subsequently the main motor are permitted to start. During normal operation of the compressor, the standby oil pump should be in auto mode and start automatically when a low-oil-pressure alarm is triggered on the DCS. If the low low-oil-pressure signal lasts more than a specified time (usually 2 s), the compressor main motor should be stopped immediately by a shutdown (trip). Since the compressor is stopped normally, post lubrication is started; this means that the lubrication oil pump will continue to run for a minimum of approximately 2 min. When post lubrication time has passed and the normal stop sequence is accomplished, the oil pump can either be stopped by the operator or continues running. Note that in maintenance mode, the frame oil pump can be started individually. Moreover, the operator can enable the oil heater by pushing a button in the DCS. If the heater is enabled, the temperature of the frame lubrication oil is controlled by the switch controller inside the heater. Note that the crankcase oil temperature should not exceed 70C (160F). For safety reasons, the heater is interlocked and must be switched off when the low low oil level is activated. It should be noted that during compressor operation, the heater shall always be stopped. Compressor cylinder lubrication system. The cylinder lubrication system is pressurized by electrically driven multiple-plunger-type oil pumps (plunger per point) or by the divider block method. However, using a divider block system is not recommended because of complexity and low reliability. The cylinder lubrication system will be started locally if the cylinder oiltank level is fulfilled (above low level). When the pre-lubrication time (approximately 2 min) has elapsed, the compressor start condition cylinder
53

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Engineering Practice
pre lubrication time passed is fulfilled and displayed in the DCS, and the over lubrication time starts. The total time of the cylinder lubrication pumps running without the main motor running is cumulative via cylinder lubrication time. The compressor main motor must be started within the over lubrication time (approximately 5 min) to prevent accumulation of oil in the cylinder. If the total over-lubrication time has elapsed and the main motor is still not running, a compressor main-motorstart inhibit will be activated and an alarm remove oil collected in cylinders before re-start appears on the DCS. Resetting the over lubrication time alarm will be done by slowly rotating the compressor for a number of revolutions (usually two or three) by a barring device to distribute the accumulated lube oil among the compressor cylinders. At this time, the alarm can be reset in the DCS manually. During cylinder barring-over or maintenance operations, the cylinder lubrication should not be activated. At compressor normal stop, post lubrication time starts for approximately 2 min, and the cylinder oil pump switches off automatically afterwards. By pressing the emergency stop, the cylinder oil pump stops immediately and no post lubrication is carried out. The cylinder lubricationoil pumps should run while the compressor main motor is running. In the event of low flow, an alarm will be triggered in the DCS and in the case of low low-flow, compressor trip action will be activated. Moreover, the operator can enable the oil heater by pushing a button in the DCS. If the heater is enabled, the temperature of the cylinder lubrication oil is controlled by a switch controller inside the heater body. The heat density of the heater should be limited to 2.3 W/cm2 (15 W/in.2). A temperature switch prevents overheating. An over temperature switch activates an alarm and switches off the heater. For safety reasons, the heater is interlocked and must be switched off when the low low-oil level is activated. Compressor cooling water system. Minimum cooling water flow to the cylinders and packings is one of the al54

lowed conditions for starting the main motor. As long as low flow is detected during normal running, an alarm will be triggered in the DCS. In a closed cooling cycle, the system is pressurized through two electrically driven water pumps. One pump is used for normal operation (main pump) and the second is in standby mode as an auxiliary for necessary conditions. For the compressor to get a permissive start, it is necessary to run the main water pump in order to deliver a minimum required flow of cooling water. Auxiliary water pumps can be started, as long as the water-pressure or low-flow alarm is activated in the DCS. Main motor purging system. The main-motor purge system is an independent working system. In EExp drivers, the motor becomes explosionproof by pressurizing its cage. The main drive motor should be started only if it has been purged with air for a period of time specified by the motor manufacturer. (Purge time is approximately between 30 to 60 min).

Preparation before starting


Before the compressor is allowed to be started, the following checks and conditions have to be fulfilled in the field: Check if the cooling-water supply valves are open (for inter-stage gasand oil-system coolers). Moreover, the cooling water specifications, such as flowrate, temperature and pressure, should be verified with design conditions by local instrument devices. Check the oil level in the tanks; it has to be above the minimum level on the oil sight glass. Check if the lube oil systems are ready for operation and the manual valves are in the correct position. Drain valves of all process pipes and vessels (including pulsation dampeners, inter-stage coolers and separator drums) have to be checked for the presence of liquid. If liquid is present, it should be drained. Otherwise, liquid would be carried over to the cylinder and damage the compressor when starting the main motor. Check if all utilities including instrument air, hydraulic oil (for highpressure valves actuation) and nitrogen for purging of pressure packings are available.

The main drive motor should be started only if it has been purged and the pre-lubrication time of the crank gear and cylinder have passed. This should be considered at the time of starting the compressor. Check the operability of all voltage circuits and the shut down system. The oil pumps can be started at minimum ambient temperature, whereas the compressor only when the lube oil temperature is above the minimum temperature recommended by the manufacturer (about 15C). Hence, frame and cylinder lubrication heater and tracing system should be on (temperature start permissive of motors). The compressor should be barred over by a barring device (for two to three revolutions) to ensure that liquid is not present in cylinders. Start inter-lock system. Before compressor startup, several parameters (such as level, pressure, temperature and flowrates) are checked and compared with set point values, specified by the compressor manufacturer in the set point list (set point lists include all instrument devices set values specifying alarm or trip signals). Afterwards, compressor start permission can be passed by the DCS and the next step will be executed. Note that interlocks will only prevent the start sequence from continuing, or will interrupt the start sequence unless all specified conditions are fulfilled; interlocks are not trip signals. Depending on the manufacturer and user concerns, an interlock system could be varied, but interlocks (alarm conditions) below are considered in most applications. An alarm is a signal generated automatically from an irregular state, which does not lead to a compressor shutdown. The start sequence will be aborted if an alarm occurs. In other words, an alarm will inhibit the start of the machine as long as it is active. Alarms and warnings do not stop the compressor. Causes of alarms must be investigated and rectified immediately by operators, or else they could cause the machine to trip (shutdowns). The compressor is ready to start if none of the following alarms are active: Low lube-oil tank level Low cylinder oil-tank level

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Low suction pressure High discharge pressure Low packing-purge pressure Low cylinder lube-oil flow Low crank-gear oil pressure Low crank-gear oil temperature High oil-filter differential pressure Bypass valves over stages are opened Barring gear is in safe position (barring gear disengaged) High level in separators Low compressor cooling-system flow Compressor has been barred over for a minimum of 1 min (mandatory if cylinder over-lubrication time has elapsed before) Crank-gear lube-oil pump pre-lubrication time has passed Cylinder pre-lubrication time has passed A trip is an irregular state that requires an immediate and automatic shutdown of the compressor in order to avoid damage to the equipment and personnel. Note that prior to shutdown an alarm will be indicated in the DCS to warn the operators. The following trips commence the normal stop procedure at any time of operation. The compressor is ready to start if none of the following shutdown conditions are active. The start sequence will be aborted if a trip occurs. High high-suction-gas temperature High high-discharge-gas temperature Low low-gas pressure on suction side High high-level in separators High high-main-bearing temperature High high-vibration on compressor casing and rod drop low low-upstream-bearings oil pressure Low low-cylinder lube-oil flow Starting sequence of the compressor in auto mode. Regarding compressor-package control philosophy, it could be started from the DCS or LCS (local control station). After startup, all functions will be carried out through the DCS automatically. Bypass valve controllers should be activated by the operator when the compressor start sequence has been completed successfully. For the compressor starting pro-

cedure to be deemed successful, the position of the manual valves must be as follows: Gas suction isolating valves are open Gas discharge isolating valves are open Blow-off valve and vent valve to safe location, flare, and atmosphere are closed Control valves and isolation valve on separator drain are open Shut-off valves for pressure instruments are open Bypass of separator drain is closed Separator drain valves have been put in auto mode, and their relevant interlocks are activated The preconditions for startup sequence are as follows: 1. All heaters, including oil heaters and the motor space heater, must be switched on. 2. Purge air must be available. If the purge time of the main motor has elapsed, the message purge end is displayed in the DCS. 3. The compressor has been barred over. To do this, first the compressors operating mode should be changed to maintenance mode in the DCS, and the operator in the field should engage the barring device manually. Then, the frame oil pump is started and compressor/motor jacking oil pumps will be started (with delay) afterwards because barring device operation is only possible as long as the hydro-jacking inlet-oil pressure alarm is not activated. At this time, barring over should be enabled from the local panel by pressing two buttons for operation of barring gear in clockwise and reverse direction. It should be noted that, none of prelubrication time, low-oil-temperature, or the lube-oil-pressure alarms should be activated. When barring over time (approximately 5 min) has elapsed, the operator should de-engage the barring device and remove any oil. 4. No low cooling-water-flow alarm. 5. No low-level alarm on interstate separators. 6. No low-level alarm on oil tanks. 7. No high-temperature alarm on the main motor. Permission to start. At this stage,

the frame oil pump is started, and the jacking pumps of the main motor and compressor will be started if prelube time, low oil temperature and low-pressure alarms are not active. Additionally, the following conditions should be satisfied: No low-suction-pressure alarm No high-discharge-pressure alarm Barring device in safe position (disengaged) Next, the cylinder lubrication pump will be started if all preconditions are fulfilled. This will also start the cylinder pre-lubrication timer. If the cylinder pre-lubrication time has elapsed, the compressor start condition cylinder pre-lubrication time passed is fulfilled and will be displayed in the DCS and over-lubrication time starts afterwards. The cylinder lubrication timer should be programmed as a cumulative timer. If it is not reset, it will accumulate the total time of the cylinder lubrication pump running while the main motor is not running up to the over-lubrication time limit. During this time range, it allows multiple startups as long as they are within the over-lubrication time. If the over-lubrication time has elapsed and the main motor is not running, the start-up sequence will be cancelled and an alarm to remove collected oil appears in DCS. Accumulated oil in the cylinders has to be removed by turning the barring device before another starting sequence commencement. Since cylinder lube-pump start is the last step in the start sequence prior to motor starting, impact on plant availability is minimized. If the main motor starts while overlubrication time has not elapsed, motor space heaters and lube oil heaters will be stopped at the same time. Moreover, for approximately 2 min, the low low-pressure trip on the compressor suction will be overridden to allow a stable condition without tripping the machine. After that, the overridden function will be deactivated. The jacking oil pump will be stopped 1 min after a successful start of the compressor. In this position, the compressor is now running at no load condition. In order to obtain the desired discharge pressure for each stage, the bypass valve setting must be per55

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Engineering Practice
formed manually. For this purpose, the first stage bypass valve shall be enabled to control suction pressure automatically. Note that automatic control capability of all bypass valves will have been deactivated during startup. At this time, close the second-stage discharge to first stages discharge bypass valve gradually until the desired second-stage discharge pressure is obtained. For the last stage, the desired pressure is obtained by closing the discharge isolating valve. In this way, the stroke position of the previous bypass valves are slowly adjusted to control pressure between each stage. Thus, the compressor runs in 0% capacity continuously and bypass valve positions are set for 0% capacity (or 100% turndown). It is of high importance to close the bypass valves slowly and gradually to stabilize the conditions and prevent overshooting of discharge pressure. Note that in compressors, which are only started by bypass method, the starting procedure is performed with bypass valves fully open. If an unloader valve also exists, the bypass valves are fully closed and unloader devices open the inlet valves, until compressor reaches the rated speed at 0% capacity. Due to increasing suction-valve temperature in this condition, the compressor is usually run between 5 to 10 min as maximum. After that, the performance step is increased by loading each cylinder chamber in the sequence shown in Table 1 for a compressor with two double-acting cylinders (HE = cylinder head end, CE = crank case cylinder end). After a period of time (adjustable between 5 to 15 min), in each performance step, solenoid valve activation on unloaders will be automatically switched over. This switching prevents increasing the temperature of the suction valve. Moreover, if purchase requisition states that the compressor shall run at 0% capacity for a long time, the compressor should run at 25% step capacity, and total flow is recycled by bypass valve thereafter. Due to unbalance matters, minimum load on each stage could be changed to 50%. Note that compressor mechanical stability must have priority over energy consumption.
56

TABLE 1. LOADING SEQUENCE FOR A COMPRESSOR WITH TWO DOUBLE-ACTING CYLINDERS


For 0% load (X = Loaded; 0 = not loaded) Cylinder A Cylinder B CE HE Time (min) HE CE

Bypass valves

In this section, we investigate Maximum 0 0 0 0 the capacity control procedure of (5-10 min) a reciprocating compressor with For 25% load (X = Loaded): bypass valves in two stages. As a Cylinder A Cylinder B principle rule, each stage is conHE CE CE HE trolled with one bypass valve, X 0 0 0 which is independent of the other 0 bypass valves, but valve set- 5 0 X 0 0 points are adjusted together and 10 0 0 X 0 finalized during the compressor 0 0 0 X commissioning period. Per API 15 recommendation, the maximum 20 Return to 0 Min. predicted discharge temperature For 50% load (X = Loaded): on each stage should not exceed Cylinder A Cylinder B 150C (300F). This limit applies Time (min) HE CE CE HE to all specified operating and load conditions. However, in actual 0 X 0 X 0 designation, this limitation is de- 5 0 X 0 X creased to 135C (275F) by com10 Return to 0 Min. pressor manufacturers. To control discharge tempera- For 75% load (X = Loaded): ture, pressure ratio or differential Cylinder A Cylinder B pressure is a parameter that is Time (min) HE CE CE HE considered as a controlling value. 0 X X X 0 Designers mention relevant set0 X X X tings in the instrument set-point- 5 list document. 10 X X 0 X Figure 1 shows an example of a 15 X 0 X X typical capacity-control diagram. Return to 0 Min. In this figure, PCV is pressure 20 control valve and PT is pressure For 0% load (X = Loaded): transmitter. The main objective of Cylinder A Cylinder B the capacity control is to maintain HE CE CE HE constant suction pressure (PT1). X X X X The capacity of the compressor is No controlled by bypass over the first Limitation stage (PCV1) and bypass over the second stage (PCV2). If compres- increasing again. When suction pressor suction pressure PT1 is decreased, sure is increasing, the bypasses will the first stage bypass valve (PCV1) close in reverse. Rapid valve movement causes rapid could be opened continuously up to a percent of stroke (between 50 to 60%) load change on the compressor. To preuntil suction pressure (PT2) is above vent this from happening, the bypass the setpoint of the minimum suction characteristic is linear and the stroke travel rate is approximately 2 min; pressure in the second stage. If suction pressure (PT1) still falls, however, this rate can be adjusted controller will open the second to first during compressor commissioning. Please note that, in case of higher stage bypass valve PCV2. This bypass valve will open continuously to 100%. capacity requirements, increasing the Now the first stage bypass (PCV1) will suction pressure (PT1) could increase be able to control the main suction pres- the compressor capacity. sure (PT1) with PCV2 in parallel. Thus, the desired pressure is obtained by high- Bypass and unloading valves pressure gas, which is recycled through In most process applications, compresfirst- and second-stage bypass valves. sor capacity control is established by When both valves are fully open, a suction pressure controller acting the compressor will operate in full re- on the bypass valve and step capacity cycle mode, until suction pressure is control (0, 25, 50, 75 and 100%). The

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

PCV1

PCV2

PT1

PT2

Environmental
Cooler 2 Stage 2

Cooler 1 Stage 1

Applications

FIGURE 1. Shown here is a typical setup for capacity control in a two-stage reciprocating compressor using bypass valves (PCV = pressure control valve; PT = pressure transmitter)

TABLE 2. CONDITIONS FOR UP- AND DOWN-STEPPING PARALLEL COMPRESSORS


Up-stepping: Compressor load B (Slave) 25% 25% 50% 75% 100% Down-stepping: Compress or load B (Slave) 25% 25% 50% 75% 100% No Action Downstep B Downstep B Downstep B Compressor load A (Master) 50% Downstep A Downstep B Downstep B Downstep B 75% Downstep A Downstep A Downstep B Downstep B 100% Downstep A Downstep A Downstep A Downstep A Upstep A Upstep A Upstep A Upstep A Compressor load A (Master) 50% Upstep B Upstep A Upstep A Upstep A 75% Upstep B Upstep B Upstep A Upstep A 100% Upstep B Upstep B Upstep B No Action

to m

te Wasn o ey
for example:

choice of the step depends on the setpoints of the bypass valves. Up-stepping is one-step increasing in capacity, for example, 25 to 50% and down-stepping is one step decreasing, for instance, 75 to 50%. The suction pressure controller reaches a balance in opening or closing the bypass valve depending on actually adjusted step load (02550 75100%) and actual flow through the compressor. If the actual bypass flow is smaller than 30% and higher than 5%, no up- or down-stepping action is required in the step capacity control. This means that suction pressure is only controlled by the stage bypass valve in this case. If bypass flow is lower than 1% or for a time duration (approximately 3 min) lower than 5%, bypass flow is very small, and therefore, the suction pressure controller is not able to maintain suction pressure with fully closed bypass. The step capacity control has to make the up-step, increasing the

compressor performance over 25% by adjusting the next higher step. Increasing compressor performance will cause a momentary suction pressure drop. Hence, time delay (1 min) is considered to prevent activation of low or low low-suction-pressure alarms or trips. After a certain time, suction pressure will reach stability again and restore the suction pressure to its normal value. If bypass flow is higher than 35% or for a time duration (approximately 3 min) higher than 30%, bypass flow is very high and the compressor is wasting energy. To avoid unnecessary bypass flow, the step capacity control should perform down-stepping, decreasing the compressor performance by 25%. Decreasing compressor performance will cause a pressure peak in suction. Consequently, a time delay (approximately 1 min) should be considered to prevent activation of high or high high-suction-pressure alarms or trips. After passing a certain time

Sludge drying Glycol recovery Used oil recovery Lubricant recycling

system solutions for evaporation and biopharma Processing Partners:

www.gigkarasek.at www.incontech.com

Circle 15 on p. 72 or go to adlinks.che.com/40271-15

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

57

Engineering Practice
duration, the suction pressure will reach stability again and restore the suction pressure to its normal value. The lowest automatic down-step will be to 25%. The 0% performance step is only used in compressor startup and shutdown sequences. Compressor parallel working. Generally, 10% increasing flowrate is performed by increasing suction pressure, but in many applications, two compressors are needed to send out enough flowrate downstream of the system. For this purpose, one of the compressor controllers will be master and the other the slave. The master takes the control decisions about suction pressure control and up- and down-stepping of the capacity. A slave compressor always follows the master decisions. To start two compressors, when the master machine is stable at 100% capacity, the slave machine should be started in 0% load. Then, during several steps, performance of both are equaled as much as possible. In this regard, in each stage, 25% of master compressor capacity (one step) will be decreased and 25% capacity of slave machine will be increased subsequently. Meanwhile, enough time delay (approximately 1 min) between each step should be considered so that flow stability is obtained at suction of compressors. The conditions for up- and downstep criteria are the same as for single compressor operation and are shown in Table 2. If the operator decides to take out one of the two running compressors, the selected compressor will be stopped with the following automatic steps with a time delay (approximately 1 min): The load of the selected compressor will be decreased by 25%. At the same moment, the load of the compressor that is intended to remain in operation will be increased by 25%. This method will be repeated until the selected compressor is completely unloaded (at 0% capacity). Normal compressor stop. A normal shutdown is manually initiated by the operator from the DCS or LCS, if the compressor needs to be stopped for reasons such as overhauling the machine or unit maintenance. The following actions will be taken automatically afterwards: All bypass valves will be opened by a slow ramp up to fully open position. Note that ramp shall be set slowly enough to avoid over pressurization of lower stages downstream of the bypass valves The hydro jacking pump of the main motor and the compressor will be started The main motor will be stopped, and all control valves will be de-energized and return to their fail position, especially bypass valves, which will be closed The isolating suction valve will be forced closed, and the frame lubeoil pump and cylinder-oil pump will continue to run after post-lubrication time Oil tank heaters and the motor space heater will be enabled At last, the discharge isolating valve will be closed and the compressor will be manually depressurized by relief valves (vent valves) installed in each stage Automatic stop based on trip. The automatic shutdown of the compressor is used to avoid damage of equipment and to ensure personnel safety. This stop sequence is exactly the same as a normal stop, except that the bypass valves are not opened at the first step. Emergency stop. In case of danger, manual actuation of the emergency push buttons, located around the machine or on the emergency shut down (ESD) panel, shall switch off all the electrical consumers (main motor, oil pumps, heaters, solenoid valves on bypass valves and so on). This stop sequence is similar to automatic trip stop except that no post lubrication is needed by frame and cylinder oil pumps. automatic bypass control be provided. For more flexibility of the system, an unloader valve or pocket may be furnished to decrease power loss during turndown capacity. Moreover, if the stepless method is employed, it should be supplemented with a bypass control arrangement. Edited by Gerald Ondrey

References
1. Bloch, Heinz and Soares, Claire, Process Plant Machinery, 2nd ed., Elsevier Science & Technology Books, November 1998. 2. Bloch, Heinz P. and John J. Hoefner, Reciprocating Compressors Operation & Maintenance, Gulf Publishing Co., 1996. 3. Bloch, Heinz P., A Practical Guide To Compressor Technology, 2nd ed., John Wiley and Sons, 2006. 4. Hanlon, Paul C., Compressor Handbook, McGraw-Hill, N.Y., 2001. 5. Chlumsky, Vladamir, Reciprocating and Rotary Compressors, SNTL- Publisher of technical Literature, 1965. 6. Reciprocating Compressor for Petroleum, Chemical and Gas Service Industries, API 618 5th ed., December 2007. 7. Southwest Research Institute, Advanced Reciprocating Compressor Technology, December 2005. 8. Leonard, Stephen M., Fugitive Emissions Control Technology For Reciprocating Compressor Cylinders, Dresser-Rand, Painted Post, N.Y. 9. Giampaolo, Tony, Compressor Handbook: Principles and Practice, the Fairmont Press, 2010. 10. Forsthoffer, W.E., Forsthoffers Best Practice Handbook for Rotating Machinery, Elsevier Science & Technology Books, 2011. 11. Forsthoffer, W.E., Forsthoffers Rotating Equipment Handbooks, Vol. 3, Elsevier Science & Technology Books, 2005. 12. Pichot, Pierre, Compressor Application Engineering, Gulf Publishing Co. 1986.

Authors
Ali Ghanbariannaeeni is a rotating equipment engineer at Nargan Engineers and Constructors Co. (Tehran CO 15 98 98 3116, Iran; Phone: +98-21-88-908-104-8; Fax +98-21-88-91-0173; Email: [email protected] and alighanbariannaeeni@ gmail.com). He is specialized in reciprocating, centrifugal and screw compressors, gas and steam turbines, process pumps, engines and electric machines. He obtained a B.S.M.E. degree from Iran University of Science and Technology (Tehran, Iran). Ghazalehsadat Ghazanfarihashemi is a rotating equipment engineer at Sazeh Consultants Co. (Tehran CO 1587657413, Iran; Phone: +98-21-88-532-156-7; Fax +98-21-88-731-503; Email: [email protected] and ghazanfari.gh@gmail. com). She is specialized in reciprocating and centrifugal compressors, process pumps, engines and electric machines. She obtained B.S.ME. and M.S.M.E. degrees from Sharif University of Technology (Tehran, Iran).

Stopping the compressor


Generally, three compressor-stop methods are considered regarding the permitted overhaul time of compression units and the safety level of the machine for plant protection.
58

Final remarks
Most reciprocating compressors are specified for constant speed operation to avoid excitation of torsional critical speeds. For all constant speed applications, it is recommended that an

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Solids Processing Environmental Manager

PI

Condensate

Follow this guidance to ensure that steam ejector systems, mechanical vacuum pumps and integrated vacuum systems are designed, operated and maintained to ensure process safety
Stanley S. Grossel Process Safety & Design Consultant
his article is the first in a twopart series, in which the types of process vacuum equipment (steam ejector systems and mechanical vacuum pumps) are discussed.1 Emphasis is given on how they are constructed and operate, and how to design associated parts of the systems (such as foundations, suction piping, discharge piping, and so on), to ensure safe operation. Many unit operations including distillation, evaporation, drying, crystallization, filtration, and others are often conducted under vacuum conditions. To achieve the desired vacuum, the following three process- vacuum systems can be used: Steam ejector systems Mechanical vacuum pumps Integrated vacuum systems (which combine steam ejectors and mechanical vacuum pumps) Available capacities and operating ranges for vacuum pumps and vacuum pumping systems that are most often used in process operations throughout the chemical process industries (CPI) are listed in the Table on p. 60 [1]. This article reviews the hazards associated with steam ejector systems and mechanical vacuum pumps, and recommends design and operating practices that can be taken to prevent or mitigate these dangers.
1. Editors note: This is the first half of a twopart article. Part 2 is scheduled to appear in the October 2012 issue.

TI

TI

To seal pot
Gate valve Four-way valve
T

To seal pot

PI Pressure indicator TI Temperature indicator

Steam trap

Piccolo connection

FIGURE 1. Shown here is a schematic of a three-stage steam ejector system with inter-condensers (Reprinted with permission from Ref. 1)

Steam ejector systems


Steam ejector systems are generally categorized into one of four basic types: single-stage, multi-stage noncondensing, multi-stage condensing, and multi-stage with both condensing and non-condensing stages. For many years, steam ejector systems dominated process applications thanks to their simplicity, low purchase cost, good reliability and their ability to be designed for very large capacities (in excess of 1,000,000 acfm) and be operated at very low pressures in the micron range (for instance, sixstage units are routinely designed for suction pressures in the range of 310 microns). They also are available in a variety of materials of construction. Steam ejector systems are ideal for wet-vacuum and highly corrosive applications. As a result, they are still being used instead of mechanical vacuum pumps in applications that require a reliable vacuum system that can tolerate corrosive chemicals, liquid slugs and solids carryover. Safety considerations. In general, there are very few safety problems associated with the operation of steam ejector vacuum systems. However, one safety issue associated with their design is the potential for back-streaming of steam into the process equipment. For instance, steam ejectors normally use a steam bleed to control the suction pressure. If the process

contains a water-reactive chemical (such as acetic anhydride), a steam bleed is not acceptable. If the ejector should backfire, this will push steam back into the process and could result in a possibly violent reaction, which could overpressure the system. To avoid this problem, a nitrogen bleed can be used to control the suction pressure. If the jet should back fire, nitrogen will prevent the steam from reaching the process. However, using nitrogen to control an existing multi-stage ejector may not be technically feasible. If nitrogen is to be used to control a multi-stage jet, the user must indicate this when writing the performance and equipment specifications for the steam ejector. Using nitrogen to control the suction pressure of the first stage that which is closest to the process will affect the design of subsequent stages, and using nitrogen to control suction pressure can significantly affect the design of the inter-condensers. If the back flow of steam or water into the process equipment from the ejector system can cause a serious safety or quality problem, then a liquid separator (a so-called knockout pot) may be installed between the ejector system and the process equipment. Another possible safety problem may result from the loss of the intercondenser cooling medium (usually water), which could lead to overpressure of the system.
59

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Aftercondenser

YZ intercondenser

Vacuum Systems: Recommendations For Safe Operation

Suction

Cooling water supply


PI

Steam supply Condensate

Cooling water return

Environmental Manager

In instances where suction gases, or materials entrained in the suction gases, might freeze inside the ejector, ejectors with external heating jackets can be specified. Instrumentation. It is good engineering practice to provide adequate instrumentation to monitor and control the operation of the steam ejector system. The following instrumentation items are recommended for monitoring and controlling the vacuum system, and to support troubleshooting efforts: Control system for controlling the steam bleed to maintain the desired vacuum level Pressure gage on the main steam- supply line Steam pressure gage on each ejector Suction pressure gage on the inlet to each ejector Vacuum gage to monitor absolute pressure at the process vessel A flowmeter to monitor the water flow to each inter-condenser Temperature gages on the inlet and outlet water lines to and from each shell-and-tube inter-condenser Temperature indicator in the barometric leg from each barometric condenser

TABLE 1. CAPACITY AND OPERATING RANGE FOR VACUUM PUMPS AND VACUUM PUMPING SYSTEMS COMMONLY USED IN PROCESS APPLICATIONS
Type Blind or base pressure Lower limit for process applications Single unit capacity range, ft3/min

Mechanical vacuum pumps


Design options. Mechanical vacuum pumps usually are classified as either wet pumps or dry pumps. The following lists show which mechanical vacuum pumps are wet and which are dry [2]: Wet pumps: Oil-sealed rotary vane (single- and dual-stage) Oil-sealed rotary piston Liquid ring Dry pumps: Rotary claw Rotary lobe (Roots) Rotary scroll Rotary screw Rotary vane Rotary piston Diaphragm Oil-sealed vacuum pumps. Both rotary-vane and rotary-piston vacuum pumps rely on oil for the following functions: To seal the internal clearances be60

Single ejectors One stage 50 torr 75 torr 101,000,000 Two stages 4 torr 10 torr Three stages 800 micron* 1.5 torr Four stages 100 micron 250 micron Five stages 10 micron 50 micron Six stages 1 micron 3 micron Liquid-ring pumps 60F water-sealed: One stage 50 torr 75 torr 318,000 Two stages 20 torr 40 torr Oil-sealed 4 torr 10 torr Air ejector first stage 2 torr 10 torr Rotary-piston pumps One stage 5 micron 100 micron 3800 Two stages 0.001 micron 10 micron Rotary-vane pumps Operated as a dry compres20 torr 50 torr 206,000 sor 0.5 torr 20 torr 50800 Oil-sealed, rough-vacuum pump Oil-sealed, high-vacuum pump: One stage 5 micron 100 micron 3150 Two stages 0.001 micron 10 micron Rotary-lobe blowers: One stage 100 torr** 300 torr 3030,000 Two stages 10 torr** 60 torr Integrated pumping systems Ejector-liquid ring pump 1 micron 3 micron 100100,000 Rotary-blower, liquid-ring 1.0 torr 5 torr 10010,000 pump Rotary-blower, rotary-piston 0.1 micron 0.10 torr*** 10030,000 pump 20 micron 200 10030,000 Rotary-blower, rotary-vane pump micron**** * 1.0 micron = 0.001 torr **Based on intercooled design that uses gas admitted to a trapped discharge pocket to cool the blower ***Based on using a two-stage, rotary-piston pump as the backing pump ****Based on a two-stage, rough-vacuum, rotary-vane design that exhibits a base pressure of approximately 0.5 torr
Source: Ref. 1

tween rotary components and housing to reduce gas slippage To transfer the heat of gas compression away from wear surfaces To lubricate the rotary internals To flush away moisture To inhibit corrosion of internal parts

During operation, an oil-sealed pump compresses the gas to a pressure that is slightly higher than atmospheric to expel it through the exhaust valve. At this pressure, and at an operating temperature of 70100C, active gases readily attack pump bearings, seal materials and the oil. The

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Outlet

Seal 0.0001-in. clearance

Separator baffle with screen Inlet

Discharge

Discharge valve

Oil level view port

Inlet Piston

Rotor Stator

Vanes

Slide pin

Cam

Automatic decanting arrangement

FIGURE 2. Shown here is a schematic of the internals of a rotary-vane vacuum pump (left) and a rotary-piston vacuum pump (right) (Reprinted with permission from Ref. 1)

selection of an appropriate oil for the application is critical for good pump maintenance. This dependency on the oil for internal lubrication is a limiting factor in the use of these types of pumps in the CPI. The integrity of the oil must be maintained to avoid internal damage that could cause contaminant buildup. Particulates in the oil must be filtered out ahead of the vacuum pump, and water or solvent vapors must either be removed ahead of the pump by using pre-condensers, or prevented from condensing within the pump by the use of gas ballasting (air stripping) or oil distillation. For oil-sealed, rotary-vane vacuum pumps, a variety of oils are available, each with very different properties. The sealing oil used in such pumps that are destined for chemical service has several additional requirements. For instance, it must: Be inert to chemical attack by acids, bases, halogens and halogeninduced aging) Be resistant to strong oxidants such as oxygen, chlorine and fluorine Possess good solvent power for problematic, mostly organic constituents of pumped media, such as oligomers, polymers, resins, crystalline decomposition or reaction products Both oil-sealed, rotary-vane and piston vacuum pumps need periodic oil changes. The chief purpose of changing of the oil is to remove particles that either originate from aging of the oil or particles that are generated by the process (such as dust, decomposition products, and other contaminants).

When either an oil-sealed rotaryvane or rotary-piston vacuum pump is improperly installed a hazardous condition can result. The following installation practices will minimize potential problems with these types of oil-sealed vacuum pumps [1]: Foundations. The foundation design will depend on the type and size of the oil-sealed pump. If the pump is inherently balanced, it can be mounted on any floor that is able to support the weight of the pump. However, pumps that are partially balanced, should be installed with vibration mounts or matting between the base and the floor. If the pump is not balanced, the base should be securely fastened to a concrete foundation with anchor bolts and grouting. The pump manufacturer should be consulted when designing the pump foundation. It is always good engineering practice to install flexible, bellows-type connectors in the suction and discharge piping; these can help to isolate the rest of the system from pump vibration. Suction piping. Certain precautions must be taken when installing the suction piping for an oil-sealed vacuum pump. Care must be taken to prevent any backstreaming of pump oil into the process vessel and to prevent process liquids and solids from reaching the pump. Backstreaming of oil is especially significant with larger pumps. Baffles and traps are frequently installed in the suction line to prevent this from happening. Cold traps, knockout pots, wet scrubbers, and bag filters are some of the devices used to protect the pump from

liquids and particulates in the suction stream. The degree of protection necessary will depend on the process application. If the upstream knockout pot is not continuously drained, a high-level sensor should be installed to automatically stop the pump or close an isolation valve to prevent any overflow from the knockout pot from reaching the pump. Oil-sealed vacuum pumps must be protected from flooding if the oil flow does not automatically stop when the pump is shut down. To prevent flooding, a valve can be installed in the suction line to admit air or nitrogen to break the vacuum when the pump stops. This prevents the siphoning of oil from the reservoir when the oil is not being discharged from the pump by the normal pumping action. A zerospeed switch or solenoid valve is used to actuate the air or nitrogen bleed and close the isolation valve. Closing the isolation valve allows the process to remain under vacuum and allows the vacuum in the pump to be broken more quickly. Flooding may be avoided with some oil-sealed pumps by sealing the discharge line using a barometric leg or a discharge check valve. This allows the system to pull a vacuum on the oil reservoir so that oil siphoning stops. A check valve or knockout pot must be installed in the suction line to prevent reverse flow from carrying oil into the process vessel. A knockout pot is recommended for critical applications where carryover of oil into the process vessel might result in a fire or explosion. Discharge piping. Condensable vapors that pass through an oil-sealed pump tend to condense in the discharge line. The discharge piping should slope away from the pump, and a drip-leg or knockout pot should be installed in the discharge line to prevent the backflow of condensate into the pump. Backpressure on the pump should be minimized. Serious mechanical damage can result if the pump is operated against a closed discharge valve. Discharge valves are therefore not recommended unless the pump must discharge into a common exhaust header. If a discharge valve is required, an interlock
61

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Environmental Manager

(that ensures that the exhaust valve is open before the pump can be started) is recommended; in fact, this is a condition of the warranty for some vacuum-pump manufacturers. A fine mist of oil drops is emitted with the exhaust gases that are discharged from an oil-sealed pump. Exhaust filters are normally installed to eliminate this oil mist. The most popular design has removable filter elements and can be mounted anywhere in the discharge line. Units are available that can remove up to 99.9% of the exhausted oil mist. Oil mist filters should not be allowed to become blocked, as hazardous over-pressures could occur. A differential pressure sensor and alarm can be installed on oil mist filters to monitor their operation and detect potential blockages. If the oil mist is contaminated with organic compounds from the process gas, especially if they are toxic, then an activated carbon filter should be installed after the oil mist filter. The activated carbon filter will remove these contaminants by adsorption. Pump cooling. Oil-sealed pumps must be cooled to remove the absorbed heat of compression. Both water- and aircooled models are available. Air-cooled models should be installed in an area that will allow an ample flow of fresh air to reach the pump. The jackets on water-cooled pumps usually contain small clearances that can plug with solids. A strainer or filter should be installed in the cooling water supply line to remove any solids. A regulating valve should be installed in the cooling-water supply line to control the pump operating temperature. A hightemperature cutout switch is sometimes installed to protect the vacuum pump from overheating. Movement of oil and flammable vapor droplets from oil-sealed vacuum pumps has been known to generate a static charge, which could lead to a fire or explosion [3]. To avoid or minimize this potential hazard, it is critical to inert the exhaust stream with nitrogen to eliminate oxygen or reduce it to below the limiting oxygen concentration (LOC). Also, in many cases, it is prudent to use nitrogen to dilute the gas stream upstream of the pump inlet to move it
62

out of the flammable range. It is critical that the nitrogen supply source be free of oxygen. There have been a few instances where the nitrogen supply was compromised, allowing in air that can lead to an explosion [3]. For pyrophoric gases, such as silane, special care must be taken to prevent air or oxygen from entering the system.

Liquid-ring vacuum pumps


Liquid-ring vacuum pumps are widely used in the CPI. They are available as single-stage (one or two impellers in parallel) or two-stage (two impellers in series) units. This type of pump does not require internal lubrication of the impellers, since they do not contact the housing. The sealant liquid, used for both sealing and cooling, can be virtually any liquid that is compatible with the process gas. For instance, water, low-viscosity oils, glycols and many process solvents such as toluene, xylene, methanol, ethanol, propanol, butanol and ethylbenzene have been used as sealants in liquid-ring pumps. Other liquids have also been used, such as ethylene glycol and propylene glycol, and even sulfuric acid. The motor horsepower must be corrected for the sealant viscosity and density (see Reference 1, p. 273). These sealants can be recirculated in a full recovery system that includes a gasliquid separator tank and a heat exchanger to cool the sealant liquid. Even higher vapor-pressure sealants can be used if a low-temperature coolant (such as glycol solution) is used in the heat exchanger to reduce the sealant liquid temperature. This recovery system allows process materials to be collected in the pump and either returned to the process or collected for disposal, thereby minimizing contamination of other liquids or the environment. The most advantageous property of liquid-ring vacuum pumps is the fact that they are nearly isothermal. The liquid in the pump provides an ample heat sink for the removal of the heat of compression. This means that the temperature rise in the casing is very small. It is a function of the characteristics of the sealant fluid used, its temperature, flowrate, and of course, the process gas conditions. The resulting low internal temperatures provide

improved safety, especially when compressing explosive gases and fluids. Generally, internal temperatures in liquid-ring vacuum pumps are the lowest of most mechanical vacuum pumps. Hence, gases exit at almost the same temperature, or in some cases, at a lower temperature than they enter the vacuum pump. Further, since the gases handled are in direct contact with large amounts of sealant liquid, even if touching of internal parts (the rotor with the casing) occurs, the resulting sparks are not hot enough or of sufficient duration to cause explosions or ignition of even the most hazardous gases. This provides a significant safety advantage, especially when handling easily ignitable gas streams. The occurrence of an explosion within liquid-ring vacuum pumps handling flammable vapors is very unlikely as the sealant liquid in the pump casing acts as a hydraulic flame arrester, quenching any flame that may be generated and preventing it from propagating. However, one of the major drawbacks of liquid-ring vacuum pumps is that they must cope with cavitation when running at low inlet pressure. If cavitation is allowed to continue over long periods of time, serious damage can be done to the pump. The amount of cavitation can be affected by the sealant liquid, sealant temperature, impeller speed, blade angle and inlet pressure. For a given pump and sealant liquid, cavitation can normally be suppressed by bleeding air (or nitrogen) into the pump inlet to raise its total pressure above the vapor pressure of the sealant at operating temperatures. All liquid-ring pump units have auxiliary equipment such as a vapor-liquid separator, a sealant recirculation pump, a sealant cooler, and various instrumentation items, relief devices and valving. Some advantages and disadvantages of liquid-ring pumps are summarized below: Advantages: Has a simple design that uses only one rotating assembly Can be fabricated from any castable material Creates minimal noise and vibration

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

In this sector liquid moves outward, draws gas from inlet ports into rotor chambers

In this sector liquid moves inward, compresses gas in rotor chambers

Inlet connections Body Liquid

Rotating liquid compressant

Inlet port

Inlet port

Rotor

In this sector compressed gas escapes at discharge ports

Discharge ports

Discharge connections

Experiences little increase in the temperature of the discharged gas Experiences no damage from liquid or small particles in the process gas Enables simple maintenance and rebuilding Uses a relatively slow rotational speed (1,800 rpm or less), which maximizes operational life Can use any type of liquid for the sealant fluid in situations where co-mingling of the sealant with the process vapor is permissible Has no lubricating liquid in the process equipment to be contaminated Can accommodate both condensable and non-condensable gases while operating as both a vacuum pump and condenser Disadvantages: Mixing of the condensed gas/vapor with the sealing liquid, which requires external equipment to separate them The risk of cavitation requires a portion of the process load to be noncondensable under operating conditions High power consumption requires large motors to form and maintain the liquid ring Achievable vacuum is limited by the vapor pressure of the sealant liquid at the operating temperature The power consumption of a liquidring pump is normally higher than that of other types of mechanical vacuum pumps The proper installation of a liquid-ring vacuum pump is critical to its operation and maintenance. The following recommendations should be followed to ensure proper installation [1, 4]: Foundations and pump checking.

FIGURE 3. This gure shows a crosssectional view (above) and general view of assembly (right) of a liquid-ring vacuum pump (Reprinted with permission from Ref. 1)

Since liquid-ring pumps do not usually create vibration problems, special foundations are not required. Pumps that are about 50 hp or above are best placed on a concrete pad. Smaller units may be mounted on existing floors and skids. On pumps of all sizes, the base should be leveled and the coupling alignment should be checked during installation. On belt-driven models, the sheaves should be aligned and the proper v-belt tensions set according to the manufacturers instructions. After the motor has been wired, the pump rotation must be checked to ensure that the polarity is not reversed. Do not test the polarity without liquid in the pump. Suction piping. A check valve or a valve that closes automatically when the motor is shut down should be installed in the suction line to prevent dumping of the liquid from the pump back into the upstream process vessel in the event of pump failure. This check valve will also serve to prevent any backflow of air into the upstream process vessel. Where protection against backstreaming air is critical due to process requirements, the vent and drain on

the separator should be barometrically sealed. This can be accomplished by discharging to a seal pot or by installing a vertical run in the suction line to serve as a barometric leg between the pump and the process vessel. If the suction line is used as a barometric leg, the vacuum pump discharge must be sealed beneath the liquid level in the separator. A vacuum relief device should be installed in the suction line on pumps that are not automatically controlled. Otherwise, the pump may cavitate during operation at low suction pressures or when it is dead-headed by mistake. The vacuum relief valve should be connected to a supply of inert gas (usually nitrogen) if admitting air to the system is unacceptable. If inlet spray nozzles are used to condense incoming vapors, the nozzles should be located in the suction piping as close as possible to the pump. An enlarged pipe section or a small vessel may be needed to provide contacting space between the spray liquid and incoming vapors. Discharge piping. The pump and discharge piping must be installed to minimize backpressure on the pump.
63

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Environmental Manager

Both the compressed gases and the sealing liquid are discharged through the pump discharge connection, and the discharge piping must be sized for two-phase flow. Piping of the same diameter as the discharge connection will usually be adequate, but a larger line may be required if the distance to the vapor-liquid separator is more than a few feet. The discharge piping should never rise more than 23 ft above the pump before the gas and liquid are separated. The discharge piping should be designed so that it is free to drain after a shutdown. Pump draining. The pump casing should be drained to the shaft level before a liquid-ring pump is started. Starting the pump when it is completely filled with liquid will overload the motor and place undue mechanical stresses on the shaft and rotor. Shaft failure is not uncommon on large liquid-ring pumps operated in this way. A solenoid valve installed in the sealant supply line to the pump is the best way to stop the flow of sealant when the pump is shut down. It will not be necessary to drain any residual liquid from the casing. If sealant is recirculated from the vapor-liquid separator, the sealant will automatically drain to the shaft level if the separator is designed with an overflow nozzle at the pump shaft level. The sealant may be manually drained to the shaft level through a hole drilled in the pump casing or by a drain in the sealant supply line. If the pump is located outdoors or in unheated buildings, it should be completely drained for freeze protection during prolonged shutdowns. Similarly, the pump must never be restarted dry; it must be partially filled with sealant liquid. This may necessitate a bypass around the solenoid valve in the sealant supply line. Sealant piping. There are three possible arrangements for sealant flow to liquid ring pumps: Once-through (no recovery), closed loop (recirculated sealant) and partial recirculation system (partial recovery). Once-through arrangement. A oncethrough installation does not necessarily imply that none of the sealant is recovered; rather, the term simply refers to the absence of any return piping from the vapor-liquid separa64

Edwards Vacuum

FIGURE 4. This is a cutaway view of a rotary-claw type dry vacuum pump, showing all components of the pump

tor drain to the pump-sealant supply connection. This is a common arrangement where conservation or contamination of the seal liquid is not a concern. The line supplying sealant to the pump should contain a shut-off valve followed by a strainer with a blowdown valve to remove particulates. An automatic solenoid valve may be installed in the supply line, interlocked with the pump motors operation, to prevent flow of sealant to the pump in case the motor stops running, (in this case, if the motor stops, the valve closes to prevent the pump casing from filling with liquid). If a solenoid valve is used, a bypass should be installed to allow some sealant to be introduced before starting (when the pump has been completely drained). The sealant flow can be regulated manually or automatically. The manual method regulates the flow by a globe valve (upstream of an orifice), which uses pressure drop across the orifice to set the desired pressure to the pump. The orifice is usually chosen so that the proper flow to the pump is set by maintaining a pressure drop of 5 to 10 psi across the orifice. Automatic control is achieved by using a flow controller to maintain a constant pressure drop if the sealant

supply pressure tends to fluctuate. Closed loop (total recirculated sealant) arrangement. In this arrangement the system is designed to operate as a closed loop with no addition of fresh sealant. Only the vapors that condense in the pump need to be removed from the system. In actual practice, however, some fresh sealant is often continually added to control the concentration of low boilers or other contaminants in the sealant or to make up for evaporative losses from the system. A heat exchanger is installed in this system to remove the heat of compression and condensation from the sealant before it is reintroduced into the pump. The heat exchanger is normally water cooled, but any suitable coolant can be used. Often, the system is provided with a sealant recirculation pump. This allows more flexibility in the design and operation of the vacuum system. The sealant cooler can be designed for a higher pressure drop, which results in better heat transfer and reduced fouling. A recirculation pump must operate at suction pressures that are too high to siphon an adequate flow of sealant from the separator and in operations involving frequent or prolonged evacuation. A recirculation pump is often used for

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

systems in which several vacuum pumps share a common separator. The fresh sealant makeup line is installed in much the same way as for a once-through installation. In addition, a check valve should be installed in the makeup line to prevent reverse flow if makeup supply pressure is lost while the vacuum pump is operating. The recirculation line should contain a strainer and one or more temperature gages. The strainer removes solids that would otherwise accumulate in the sealant. Temperature gages should be installed on both sides of sealant coolers to monitor heat exchanger performance. Partial recirculation (partial recovery) arrangement. A partial recirculation system has no sealant cooler. Fresh solvent makeup is used as the heat sink. A portion of the total sealant flow is supplied as cold makeup and the rest is recirculated from the separator. The fresh and recirculated streams mix and come to some intermediate temperature before entering the vacuum pump. The desired temperature is controlled by varying the ratio between the two streams until a satisfactory temperature is reached. A partial recirculation arrangement can reduce fresh sealant requirements by 50% or more compared with oncethrough systems, depending on the temperature of the fresh stream. The recommendations about piping design and filters given in the section on closed-loop arrangements apply here as well. Potential hazards and options to prevent or mitigate them. Listed below are some potential hazards of liquid-ring vacuum pumps and measures that can be used to prevent or mitigate them [5]: The escape of flammable or toxic vapors from failed mechanical seals can create external hazardous conditions. Liquid-ring vacuum pumps handling non-hazardous vapors usually are provided with single mechanical seals. If these pumps handle flammable or toxic vapors, then double mechanical seals should be installed with seal-welded connections to eliminate leak paths Improper installation, mounting, and alignment of pumps: This can

cause damaging vibration, which can lead to potential seal or other mechanical failures and leakage to the environment of internal fluids (sealant, gas or both) Improper installation of piping can result in external loads on the casing leading to pump failure, or again, leakage of internal fluids to the atmosphere Liquid-ring pumps use seal liquids that are in direct contact with the process gases, and if the gases pumped are flammable or toxic, the discharged gases and sealants will potentially also be hazardous Since seal liquids are in direct contact with the process gases, liquid ring pumps act as mixers in a sense, and any potential reactions between the seal liquid and the process gas must be considered Gases and seal liquids are discharged together and proper separation must be done if the gases are to go to subsequent processes. If gases or vapors condense or dissolve in the seal liquid, consideration must be given to selecting the proper materials of construction for the discharge system to resist attack by any of the gases present in the process gas stream to the pump, or introduced and/or formed in the seal liquid Seal liquids, if recirculated, will become saturated to equilibrium states with the process gases being pumped. As a result, the overflows from a liquid-ring pump system must be treated as a hazardous liquid if the gases are flammable or toxic. Since, in many cases the seal liquid is reused in the system, the concentrations of contaminants can increase with time Since compression in a liquid-ring vacuum pump is essentially isothermal, this means that any vapors or gases exiting will be saturated with the seal liquid and that any potentially hazardous vapors or gases may condense and be discharged as liquids to the discharge system Proper materials of construction must be selected if liquid-ring pumps use seal liquids that are corrosive (such as sulfuric acid) or if the process gases contain corrosive components

Liquid-ring vacuum pumps are not generally built for high pressures and use non-live sealed gasket systems for the most part. This means that if pressure can rise in hazardous systems quickly, the liquid ring system is often the lowest pressure component, and must be protected from the rise or particular design variations made, to ensure that they are resistant to maximum pressures that may occur

Dry vacuum pumps


Dry vacuum pumps have been used since the 1980s, originally in the semiconductor industry, then in the pharmaceutical industry, and now in other chemical process applications. They have several advantages, as follows: No contamination of the process caused by backstreaming of sealing liquids or lubricating oils No contamination of evacuated gas with sealing liquid or lubricant Due to lack of condensation (which is assured because the pump runs hot), the pump can be fabricated of standard, inexpensive cast iron They have a rugged rotor design which is constructed of sturdy cast iron, or ductile iron, without any flimsy rotating components Noncontact design: Timing gears are oil lubricated in a sealed-off end chamber to synchronize the rotors for proper phasing and noncontacting operation High operational speed: Operation at high speeds reduces the ratio of gas slip to displacement, increases net pumping capacity and reduces ultimate pressure. To accomplish this, the rotors are well balanced They can be designed with multiple staging The pump can discharge to the atmosphere They can be used for handling corrosive gases They can be used for handling flammable gases as the pumps are designed for containment of an internal explosion for this service However, they also have the following drawbacks: They cannot handle particulates, nor slugs of liquid They may require a silencer
65

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Environmental Manager
They may discharge gases at high temperatures, in some cases as high as 350400C. Newer designs allow running at lower temperatures and have precise temperature control Some models are difficult to repair or rebuild They may require a gas purge for cooling or to protect the bearings and seals from the process gas Due to the high operating temperature, some process materials such as monomers, may have a tendency to polymerize An excellent overview of dry vacuum pumps is presented by Ryans and Bays [6]. Two types of vacuum pumps that are used in high and ultra-high vacuum applications are the turbomolecular pump and diffusion pump. However, they are not discussed in this article. Edited by Suzanne Shelley

References
1. Ryans, J.L., and Roper, D.L., Process Vacuum System Design and Operation, McGraw-Hill Book Co., New York, N.Y.1986. 2. Chew, A.D., Mechanical Vacuum Pumps, BOC Edwards paper. 3. Private communication (email) of July 8, 2011 from Mark Nichols of Edwards Limited. 4. Aglitz, A., and others, Installing liquid ring vacuum pumps, Chem. Eng., November 1996. 5. Private communication (email) of August 11, 2011 from John Campbell of SIHI Pumps Americas. 6. Ryans, J., and Bays, J., Run clean with dry vacuum pumps, Chem. Eng. Prog., pp. 3241, October 2001. 7. Edwards Ltd., Safety Manual-Vacuum Pump and Vacuum Systems, 2008. 8. NFPA 69, Standard on Explosion Prevention Systems, National Fire Protection Association, Quincy, Mass., 2008.

Author
Stanley S. Grossel is president of Process Safety and Design, Inc. (4 Marble Court, Unit 9, Clifton, N.J. 07013-2212; Phone: 973-779-3668; Email: [email protected]). He provides consulting services related to process safety and loss prevention, storage and handling of bulk solids and powders, air pollution control, and process design of batch plants. Prior to his 1993 retirement, Grossel spent 25 years in the Engineering Dept. of Hoffman-LaRoche, in a variety of roles. He was honored as the only Senior Engineering Fellow ever to be designated by Hoffman-LaRoche. Grossel is a fellow of AIChE, and holds AIChEs Norton Walton/Russell Miller Award for outstanding contributions to loss prevention. He has lectured and been published widely, and has authored major standards and guidelines. Grossel is also a contributor on process safety to the 7th Ed. of Perry's Chemical Engineers Handbook. He holds a B.S.Ch.E. from City College of New York and an M.S.Ch.E. from Drexel Inst. of Technology, and has completed courses toward a doctoral degree.

Acknowledgements
The author wishes to thank J.L. Ryans of Eastman Chemical Co. (Kingsport, Tenn.) for his review of the draft of this article and for his helpful comments and recommendations. I also acknowledge the assistance of the fol-

lowing people who provided technical information that was used in writing this article: Peter N. Lodal (Eastman Chemical Co.), John Campbell (SIHI Pumps Americas), Mark Nichols (Edwards Ltd.), and Eric Johnson (Graham Manufacturing Co.).

SEPTEMBER 2012

CHE.COM

Literature Review
Featuring Brochures and Catalogs of Products and Services for the CPI Visit CE Lit Online at che.com

Precise Density Measurement For Caustics and Acids


The Dynatrol Density System is designed to handle temperatures up to 300 while calculating specific gravity, Baum and percent concentration. Provides exceptional resistance to corrosion from caustics, acids, ammonia, sulfuric acid, hydrochloric acids, and nitric acids. Choose from Tantalum media contact parts or Hastelloy C-276, Carpenter 20, and Stainless Steel. Call 800-231-2062 x19 for a free Catalog today! Or visit www.DynatrolUSA.com
Circle 291 on p. 72 or go to adlinks.che.com/40271-291

EquipNet provides asset management services to world-class chemical companies


Our offerings include asset evaluation and appraisal, site reconfiguration consulting, project management, and sales and marketing. These services yield a large supply of high-quality process equipment and unused MRO parts available for sale at the EquipNet MarketPlace, the largest website of its kind. Contact: John Cote, Managing Director: Chemical (781) 821-3482 x2103 [email protected] www.EquipNet.com/chem
Circle 292 on p. 72 or go to adlinks.che.com/40271-292

66

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

CHEMICAL ENGINEERING WWW.CHE.COM JUNE 2012

66

Now Available in the Chemical Engineering Store:

Process Water and Wastewater Treatment and Reuse Guidebook- Volume 2

This guidebook contains how-to engineering articles formerly published in Chemical Engineering. The articles in Volume 2 provide practical engineering recommendations for process operators faced with the challenge of treating inlet water for process use, and treating industrial wastewater to make it suitable for discharge or reuse. There is a focus on the importance of closed-loop or zero-discharge plant design, as well as the selection, operation and maintenance of membrane-based treatment systems; treating water for use in recirculatedwater cooling systems; managing water treatment to ensure trouble-free steam service; designing stripping columns for water treatment; and more.
Table of Contents Process Water Treatment Challenges and Solutions Water Reuse and Conservation in the CPI Strategies to Minimize Wastewater Discharge Strategies for Water Reuse Wastewater: A Reliable Water Resource Membranes for Process Water Reuse Strategies for Controlling Membrane Fouling Fact at Your Fingertips: Membranes Facts at Your Fingertips: Membrane Congurations Facts at Your Fingertips: Controlling Membrane Fouling Biodegradation and Testing of Scale Inhibitors Keeping Cooling Water Clean Caring for Cooling Water Systems Purifying Coke-Cooling Wastewater Non-Chemical Water Treatment CPI Water and Steam Chemistry Designing Steam Stripping Columns for Wastewater

Order your copy today by visiting store.che.com


20611

Environmental Fractionation Column Manager

Try harder to stay awake

obody would have ever called Denny proactive. He wasnt even reactive. He was barely active in any sense of the word. A majority of his acquaintances would have, in fact, called him inactive. Nevertheless, Denny was on our sales team, albeit the junior member. Dan was the division vice president. If Dan ever smiled, I dont remember it. He wasnt very inspiring. In fact, when he spoke, he usually depressed us, at least until bowling night. Denny, Dan and I went to an oil city to talk to an angry oil company about a highest-cost bid we had submitted. It was my job to convince the oil company engineers that ours was truly the only viable option. It was not my job

Mike Resetarits is the technical director at Fractionation Research, Inc. (FRI; Stillwater, Okla.; www.fri.org), a distillation research consortium. Each month, Mike shares his rst-hand experience with CE readers

to talk cost or price. Our salespeople were instructed to keep the technical experts clean uncontaminated by cost/price negotiations. I was truly convinced that ours was the only option. I gave a one-hour presentation attempting to prove it. Thereafter, the oil company engineers put me through a ringer. I kept my cool. I had most of the answers. I explained my answers to their apparent satisfaction. Then, they said, Now lets talk about your ridiculous price. I turned to Denny, who had been sitting patiently in a corner. Dan and the

RECEIVE FULL ACCESS


to ALL of Chemical Engineerings

Facts at Your Fingertips articles

in one convenient location.

EACH INFORMATION PACKED PDF


article includes graphs, charts, tables, equations and columns on the full chemical engineering processes you deal with on a daily basis. This is the tool you will come to rely on, referring back to the information again and again with just the click of a mouse. Facts at Your Fingertips Topics Include:
Conservation Economics: Carbon Pricing Impacts Distillation Tray Design Burner Operating Characteristics Measurement Guide for Replacement Seals Steam Tracer Lines and Traps Positive Displacement Pumps Low-Pressure Measurement for Control Valves Creating Installed Gain Graphs Aboveground and Underground Storage Tanks Chemical Resistance of Thermoplastics Heat Transfer: System Design II Adsorption Flowmeter Selection Specialty Metals Plus much, much more
17872

68

Receivefull fullaccess accesstoday todayby by visiting visiting Receive www.omeda.com/cbm/facts http://store.che.com/product/facts

Circle XX on p. 60 or go to adlinks.che.com/40270-XX
CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

oil company engineers also turned toward Denny. Denny was fast asleep. In fact, he was past fast asleep and nearly comatose. He was stretched way out in the conference room chair. His arms were hanging almost to the floor. His mouth was wide open and two flies were perched on his lips wondering about todays lunch. In a raised voice, Dan said, Hey, Denny! Denny awoke with a start. He didnt seem as embarrassed as he should have been. Being embarrassed would have been appropriately reactive, but reactive was not Dennys way, as I said previously. Dan asked Denny to review our costing strategy. Dennys response was half-hearted and lacking in details and understanding. It was lunchtime. The oil company engineers let us off the hook. We were led unceremoniously to the main lobby and a taxi. In the taxi, Dan did all the talking. I was talked out; Denny was talked at. Dan fired Denny, recounting all of Dennys previous occasions of non-proactivity and non-reactivity. I looked out the taxi window hoping that the airport would arrive real soon. Luckily, in the airport, we caught three totally different flights. All of us have had occasions where we have nodded off, or nearly nodded off, at meetings or presentations. There are several remedies. Drink more morning coffee. Stand up in the back of the room. Take rest room breaks. Participate more fully in the discussions. Take detailed notes. Stick to a weekend sleep schedule that matches your weekdays. Avoid caffeine during evenings. Fly to overseas meetings one day early. There are some days where sleep is more fun than anything else on your action list. Get more if you can. Mike Resetarits [email protected]

PRODUCT SHOWC ASE


High Accuracy In-Line Viscosity Measurement Dynatrol Systems

FAST and EASY CONTINUOUS READINGS


Operates in a wide range of conditions Excellent success with asphalt, adhesive, paints, primers and other industrial products. Rugged performance with amazing longevity CSA NRTL/C approved for Class 1 Group D Div 1 Microprocessor based - digital accuracy Outstanding repeatability in Newtonian or shear thinning liquids Stands up to harsh industrial environments

Automation Products, Inc. 800-231-2062 713-869-0361 [email protected]


Circle 201 on p. 72 or go to adlinks.ce.com/40271-201 Circle 203 on p. 72 or go to adlinks.ce.com/40271-20 Circle 202 on p. 72 or go to adlinks.ce.com/40271-202

CONSULTING
CRYSTALLIZATION & PRECIPITATION
Dr. Wayne J. Genck Genck International 3 Somonauk Court, Park Forest, IL. 60466 Tel (708) 748-7200 Fax (708) 748-7208 [email protected] http://www.genckintl.com
Design/Scale-up Size Distribution Laboratory Investigations Filtration Troubleshooting Purity Caking Drying Particle Habit Product Micro-Analysis Polymorphism Kinetics Studies

Protect pressure or vacuum instruments from clogging, corrosion and damage.


Compact and Economical, Plast-O-Matic Gauge Guards prevent dangerous leaks and allow dependable instrument readings from full vacuum to 250 psi.

PTFE or FKM diaphragms. PVC, Polypro or PVDF bodies. Available with or without gauges. Gauge Shields for harsh environments.
ACOUSTICAL BUILDING DESIGN COMMISSIONING TESTS

Industrial Seminars Circle 243 on p. 72 or go to adlinks.che.com/40271-243

FERC, EUB, OSHA, NEPA PLANT NOISE CONTOURS

Advertise in the Classified


CONTACT:

NOISE MEASUREMENT, ASSESSMENT, AND CONTROL COMPUTER NOISE MODELING

HFP ACOUSTICAL CONSULTANTS


NOISE CONTROL ENGINEERING
HOUSTON, TEXAS (713) 789-9400 CALGARY, AB (403) 259-6600

Diane Hammes Eric Freer Tel: Tel:512.250.9555 713.343.1904 Fax: 512.213.4855 Fax: 832.251.8963 email: [email protected] email: [email protected]

www.HFPacoustical.com/CE
INDUSTRIAL AND ENVIRONMENTAL SOUND LEVEL SURVEYS REGULATORY COMPLIANCE STUDIES

Circle 249 on p. 72 or go to adlinks.che.com/40271-249

CEDAR GROVE, NJ 07009 (973) 256-3000 Fax: (973) 256-4745 www.plastomatic.com [email protected]

PLAST-O-MATIC VALVES, INC.

Circle 204 on p. 72 or go to adlinks.ce.com/40271-204 CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

69

Intelligen Suite
The Market-Leading Engineering Suite for Modeling, Evaluation, Scheduling, and Debottlenecking of Multi-Product Facilities

SuperPro

SchedulePro

Use SuperPro Designer to model, evaluate, and optimize batch and continuous processes

Migrate to SchedulePro to model, schedule, and debottleneck multi-product facilities

Easy production tracking, conflict resolution and rescheduling

Tracking demand for resources (e.g., labor, materials, utilities, etc.)

Managing inventories for input, intermediate, and output materials

SuperPro Designer is a comprehensive process simulator that facilitates modeling, cost analysis, debottlenecking, cycle time reduction, and environmental impact assessment of integrated biochemical, bio-fuel, fine chemical, pharmaceutical (bulk & fine), food, consumer product, mineral processing, water purification, wastewater treatment, and related processes. Its development was initiated at the Massachusetts Institute of Technology (MIT). SuperPro is already in use at more than 500 companies and 900 universities around the globe (including 18 of the top 20 pharmaceutical companies and 9 of the top 10 biopharmaceutical companies). SchedulePro is a versatile production planning, scheduling, and resource management tool. It generates feasible production schedules for multi-product facilities that do not violate constraints related to the limited availability of equipment, labor, utilities, and inventories of materials. It can be used in conjunction with SuperPro (by importing its recipes) or independently (by creating recipes directly in SchedulePro). Any industry that manufactures multiple products by sharing production lines and resources can benefit from the use of SchedulePro. Engineering companies use it as a modeling tool to size shared utilities, determine equipment requirements, reduce cycle times, and debottleneck facilities.

Visit our website to download detailed product literature and functional evaluation versions of our tools INTELLIGEN, INC. 2326 Morse Avenue Scotch Plains, NJ 07076 USA Tel: (908) 654-0088 Fax: (908) 654-3866 Email: [email protected] Website: www.intelligen.com
Intelligen also has offices in Europe and representatives in countries around the world
Circle 240 on p. 72 or go to adlinks.che.com/40271-240

SOFTWARE

Circle 241 on p. 72 or go to adlinks.che.com/40271-241

GET CONNECTED TODAY

www.che.com
Engineering e-material, e-solutions, e-courses and e-seminars for energy conversion systems:
Physical Properties Steam Approximations Power Cycles Power Cycle Components/Processes Compressible Flow ENGINEERING SOFTWARE Phone/FAX: (301) 540-3605 Web Site: http://www.engineering-4e.com Visit the web site to check out free demos etc.!

Circle 244 on p. 72 or go to adlinks.che.com/40271-244

Circle 242 on p. 72 or go to adlinks.che.com/40271-242

NEW & USED EQUIPMENT


HEAT EXCHANGERS

Liquid Cooled

HIGH SHEAR MIXERS


Worlds Widest Selection, Single Stage to Ultra High Shear!

12 -200 HP batch and inline Free Engineers! trials in your plant Talk Directly with Design Blower Cooling Vent Condensing Many sizes in stock
FOR

Air Cooled

GASES & LIQUIDS!

Ross will beat any major manufacturers quote!


(952) 933-2559 [email protected]

Circle 248 on p. 72 or go to adlinks.che.com/40271-248

1-800-243-ROSS
USA Tel: 631-234-0500 Fax: 631-234-0691

www.highshearmixers.com

WABASH SELLS & RENTS


Boilers
20,000 - 400,000 #/Hr.

Circle 246 on p. 72 or go to adlinks.che.com/40271-246

Diesel & Turbine Generators


50 - 25,000 KW

Gears & Turbines


25 - 4000 HP Air Pre-Heaters Economizers Deaerators Pumps Motors Fuel Oil Heating and Pump Sets Valves Tubes Controls Compressors Pulverizers Rental Boilers & Generators

We stock large inventories of:

ADVERTISE IN THE CLASSIFIED


Contact Diane Hammes Tel: 512-250-9555 Fax: 512-213-4855 Email: [email protected]
Circle 245 on p. 72 or go to adlinks.che.com/40271-245
CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

24/7 Fast Emergency Service

800-704-2002
Phone: 847-541-5600 Fax: 847-541-1279

www.wabashpower.com

wabash

POWER EQUIPMENT CO.

444 Carpenter Ave., Wheeling, IL 60090

Circle 247 on p. 72 or go to adlinks.che.com/40271-247

71

New Product Information September 2012 JustFAXit! or go to www.che.com/adlinks


name Company address City Country\ email | | | | | | | | | | | 14 15 16 17 18 | | | | State/province telephone | | | | | | | | | 29 30 31 32 33 34 | | | | | Zip/postal Code Fax | | | | | | | | 47 48 49 50 51 52 53 54 55 56 57 58 59 | | | | | | title

FREE PRODUCT INFO


(please answer all the questions)

YOUR INDUSTRY 01 Food & beverages 02 wood, pulp & paper 03 inorganic Chemicals 04 plastics, Synthetic resins 05 Drugs & Cosmetics 06 Soaps & Detergents 07 paints & allied products 08 organic Chemicals 09 agricultural Chemicals 10 petroleum reining, Coal products 11 rubber & misc. plastics 12 Stone, Clay, glass, Ceramics 13 metallurgical & metal products
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 101

engineering, Design & Construction Firms engineering/environmental Services equipment manufacturer energy incl. Co-generation other

10 to 49 employees 50 to 99 employees 100 to 249 employees 250 to 499 employees 500 to 999 employees 1,000 or more employees

JOB FUNCTION 20 Corporate management 21 plant operations incl. maintenance 22 engineering 23 research & Development 24 Safety & environmental 26 other EMPLOYEE SIZE 28 less than 10 employees

YOU RECOMMEND, SPECIFY, PURCHASE


(please circle all that apply)

40 41 42 43 44 45 46

Drying equipment Filtration/Separation equipment heat transfer/energy Conservation equipment instrumentation & Control Systems mixing, blending equipment motors, motor Controls piping, tubing, Fittings

pollution Control equipment & Systems pumps Safety equipment & Services Size reduction & agglomeration equipment Solids handling equipment tanks, Vessels, reactors Valves engineering Computers/Software/peripherals water treatment Chemicals & equipment hazardous waste management Systems Chemicals & raw materials materials of Construction Compressors
526 541 556 571 586

106 121 136 151 166 181 196 211

226 241 256 271 286 301 316 331 346 361 376 391 406 421 436 451 466 481 496 511

107 122 137 152 167 182 197 212 227 242 257 272 287 302 317 332 347 362 377 392 407 422 437 452 467 482 497 512 527 542 557 572 587 108 123 138 153 168 183 198 213 228 243 258 273 288 303 318 333 348 363 378 393 408 423 438 453 468 483 498 513 528 543 558 573 588 109 124 139 154 169 184 199 214 229 244 259 274 110 111 112 113 114 116 289 304 319 334 349 364 379 394 409 424 439 454 469 484 499 514 529 544 559 574 589 125 140 155 170 185 200 215 230 245 260 275 290 305 320 335 350 365 380 395 410 425 440 455 470 485 500 515 530 545 560 575 590 126 141 156 171 186 201 216 231 246 261 276 291 306 321 336 351 366 381 396 411 426 441 456 471 486 501 516 531 546 561 576 591 127 142 157 172 187 202 217 232 247 262 277 292 307 322 337 352 367 382 397 412 427 442 457 472 487 502 517 532 547 562 577 592 128 143 158 173 188 203 218 233 248 263 278 293 308 323 338 353 368 383 398 413 428 443 458 473 488 503 518 533 548 563 578 593 129 144 159 174 131 146 161 176 189 204 219 234 249 264 279 294 309 324 339 354 369 384 399 414 429 444 459 474 191 206 221 236 251 266 281 296 311 489 504 519 534 549 564 579 594 130 145 160 175 190 205 220 235 250 265 280 295 310 325 340 355 370 385 400 415 430 445 460 475 490 505 520 535 550 565 580 595 326 341 356 371 386 401 416 431 446 461 476 491 506 521 536 551 566 581 596 132 147 162 177 192 207 222 237 252 267 282 297 312 327 342 357 372 387 402 417 432 447 462 477 492 507 522 537 552 567 582 597 133 148 163 178 193 208 223 238 253 268 283 298 313 328 343 358 373 388 403 418 433 448 463 478 493 508 523 538 553 568 583 598 134 149 164 179 194 209 224 239 254 269 284 299 314 329 344 359 374 389 404 419 434 449 464 479 494 509 524 539 554 569 584 599

100 115 102 117 103 118 104 119

105 120 135 150 165 180 195 210 225 240 255 270 285 300 315 330 345 360 375 390 405 420 435 450 465 480 495 510 525 540 555 570 585 600

if number(s) do not appear above, please write them here and circle:

Fax this page back to 800-571-7730


ADVERTISING SALES REPRESENTATIVES
Jason Bullock, District Sales Manager Chemical Engineering 8325 broadway, Ste. 202/pmb 261 pearland, tX 77581 tel: 281-485-4077; Fax: 281-485-1285 E-mail: [email protected]; Arkansas, Arizona, California, Colorado, Georgia, Kansas, Louisiana, Missouri, New Mexico, Nevada, Oklahoma, Texas, Washington Dan Gentile District Sales Manager tel: 512-918-8075 E-mail: [email protected] Indiana, Illinois, Iowa, Minnesota, Wisconsin Diane Hammes Inside Sales Manager Chemical Engineering; 11000 richmond ave, Suite 690, houston, tX 77042 tel: 713-444-9939 E-mail: [email protected] Product Showcase, Literature Reviews, Classiied Display Advertising

North America Eric Freer, District Sales Manager Chemical Engineering 11000 richmond ave, Suite 690, houston, tX 77042 tel: 713-343-1904 E-mail: [email protected] Alabama, Alaska, Canada, Connecticut, Delaware, Florida, Hawaii, Idaho, Kentucky, Maine, Maryland, Massachusetts, Michigan, Mississippi, Montana, Nebraska, New Hampshire, New Jersey, New York, North & South Carolina, North & South Dakota, Ohio, Oregon, Pennsylvania, Rhode Island, Tennessee, Utah, Vermont, Virginia, Washington, D.C., West Virginia, Wyoming, Latin America International Petra Trautes Chemical Engineering Zeilweg 44 D-60439 Frankfurt am main germany phone: +49-69-58604760 Fax: +49-69-5700-2484 email: [email protected] Austria, Czech Republic, Benelux, Eastern Europe, Germany, Scandinavia, Switzerland, United Kingdom

Dipali Dhar Chemical Engineering 88 pine Street, 5th loor, new York, nY 10005 tel: 718-263-1162 E-mail: [email protected] India Katshuhiro Ishii Chemical Engineering ace media Service inc., 12-6, 4-chome nishiiko, adachi-ku, tokyo 121, Japan tel: 81-3-5691-3335; Fax: 81-3-5691-3336 e-mail: [email protected] Japan

Ferruccio Silvera Chemical Engineering Silvera pubblicita Viale monza, 24 milano 20127, italy tel: 39-02-284-6716; Fax: 39-02-289-3849 E-mail: [email protected]/www. silvera.it Andorra, France, Gibraltar, Greece, Israel, Italy, Portugal, Spain

Rudy Teng Sales Represntative Chemical Engineering; room 1102 #20 aly 199 baiyang road pudong Shanghai 201204 China tel: +86 21 50592439 Fax: +86 21 50592442 mp: +86 13818181202 E-mail: [email protected] Asia-Paciic, Hong Kong, Peoples Republic of China, Taiwan

72

ChemiCal engineering www.Che.Com September 2012

Fill out the form and circle or write in the number(s) below, cut it out, and fax it to 800-571-7730.

go on the web and ill out the online reader service card.

Advertisers Index
Advertiser
Phone number

Page number
Reader Service #

Advertiser
Phone number

Page number
Reader Service #

Advertiser
Phone number

Page number
Reader Service #

Abbe, Paul O.

32

Hytorc

27

Petro-Canada PNC Financial

14 32a-32b

1-800-524-2188 adlinks.che.com/40271-01

1-877GUN-2-GUN adlinks.che.com/40271-17

adlinks.che.com/40271-25 1-877-535-6314 adlinks.che.com/40271-26

Automation Products, Inc.

66

1-800-231-2062 adlinks.che.com/40271-291

* KSB AG Load Controls

32I-5
adlinks.che.com/40271-18

Avecom NV

39

28

* Pompetravaini

32I-8

32 9 375 17 14 adlinks.che.com/40271-03

1-888-600-3247 adlinks.che.com/40271-19

41 61 338 18 18 adlinks.che.com/40271-27

* Bronkhorst - High Tech B.V.

32I-6 10

Micro Motion, Inc. MultiTherm LLC

4 8

Ross, Charles & Son Company

adlinks.che.com/40271-04

adlinks.che.com/40271-21 1-800-225-7440 adlinks.che.com/40271-22

1-800-243-ROSS adlinks.che.com/40271-28

Bryan Research & Engineering

Samson AG

13

1-800-776-5220 adlinks.che.com/40271-05

49 69 4009-0 adlinks.che.com/40271-29

Buhler Aeroglide

20

Myron L Company

12

1-919-851-2000 adlinks.che.com/40271-06

1-760-438-2021 adlinks.che.com/40271-23

* Siemens AG I IA&DT CC Turbomachinery Laboratory

32I-3 23

adlinks.che.com/40271-30 1-979-845-7417 adlinks.che.com/40271-31

* Buss-SMS-Canzler GmbH

32I-4

Outotec Oyj

49 60 33-85-0 adlinks.che.com/40271-07

adlinks.che.com/40271-24

Cashco VCI

1-785-472-4461 adlinks.che.com/40271-08

See bottom of next page for advertising sales representatives' contact information

Clean Harbors

26 Advertiser
Phone number

1-800-422-8998 adlinks.che.com/40271-09

Classiied Index September 2012


Page number
Reader Service #

Corzan HP Piping Systems

1-888-735-1431 adlinks.che.com/40271-20

Advertisers Product Showcase . . . . . . . . . . 69 Computer Software . . . . . . . .70-71 Consulting . . . . . . . . . . . . . . . . . 69 Equipment, New & Used . . . . . 71 Advertiser
Phone number

Applied e-Simulators Software Automation Products, Inc.

71 69

Dickow Pump Company

25

adlinks.che.com/40271-241 1-800-231-2062 adlinks.che.com/40271-201

1-800-880-4442 adlinks.che.com/40271-10

Dupre Logistics

19

1-855-686-5478 adlinks.che.com/40271-11

CU Services LLC

69

Page number
Reader Service #

Emerson Process Management Equipnet Direct

FOURTH COVER 66

1-847-439-2303 adlinks.che.com/40271-202

Intelligen Inc.

70

Engineering Software
1-781-821-3482 Ext. 2103 adlinks.che.com/40271-292

71

1-908-654-0088 adlinks.che.com/40271-240

1-301-540-3605 adlinks.che.com/40271-242

Neuhaus Neotec Plast-O-Matic Valves, Inc.

69 69

adlinks.che.com/40271-203 1-973-256-3000 adlinks.che.com/40271-204

Genck International

69

FCI

31

1-800-854-1993 adlinks.che.com/40271-12

1-708-748-7200 adlinks.che.com/40271-243

* GEA Niro

32I-7

Heat Transfer Research, Inc. HFP Acoustical Consultants

71 69

Ross, Charles & Son Company 71


1-800-243-ROSS adlinks.che.com/40271-246

45 39 54 54 54 adlinks.che.com/40271-13

adlinks.che.com/40271-244 1-713-789-9400 adlinks.che.com/40271-249

GEA Westfalia Separator Group GmbH

Wabash Power Equipment Co.

71

15

1-800-704-2002 adlinks.che.com/40271-247

49 2522 77-0 adlinks.che.com/40271-14

Indeck Power Equipment Co.

71

GIG Karasek GmbH


adlinks.che.com/40271-15

57

1-847-541-8300 adlinks.che.com/40271-245

Xchanger, Inc.

71

1-952-933-2559 adlinks.che.com/40271-248

Gorman-Rupp Company, Mansield Div.

21

1-419-755-1011 adlinks.che.com/40271-16

Send Advertisements and Box replies to: Diane Hammes


Chemical Engineering, 11000 Richmond Ave, Houston, TX 77042 E-mail: [email protected] Tel: 713-343-1885
73

* International Edition

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

People
September WHOS WHO

Nathan

Cooper

Duckworth

Shana'a

Matzen

John Nathan becomes director of operations for Magnetic Products (Highland, Mich.). Intellitect Water (Hants, U.K.) makes two appointments: Mark Duckworth becomes engineering manager in product development; Jo Cooper becomes product and market specialist. CleanTech Biofuels (St. Louis, Mo.) names James E. Russell, an independent consultant who spent 35 years with Science Applications Interna-

tional Corp. (SAIC), to its board of directors. May Shanaa becomes group vice president, technology and growth strategy, for Ashland Specialty Ingredients (Wilmington, Del.). Manfred Baumann, currently the managing director of Gerrescheimer Medical Plastic Systems (Wackersdorf, Germany), assumes international leadership of the companys new sales and engineering center, technical competence center, mold-

making, finance & controlling, IT, human resources, marketing and legal. Oliver Burgel joins the company to become chief production officer. OPX Biotechnologies (Boulder, Colo.) appoints Earl Douglas as vice president and general counsel. Christian Matzen becomes head of sales for packaging systems for Beumer Maschinenfabrik GmbH & Co. KG (Beckum, Germany). Suzanne Shelley

SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE SUBSCRIBE S U B S C SUBSCRIBE R I B E SUBSCRIBE T O SUBSCRIBE SUBSCRIBE SUBSCRIBE
July 2008
6

www. che.c om

Incorp oratin g So Into lids Liquid s

Focus on Ga s De New tection Engine ering Mater Closed ials Liquid Dispen Findin sing g the Right To Fit the Ap Gloves plicatio Facts n at You r Fin Vacuum gertips: Pump s Flowm eter News

Augu st 2008
8

www. che.c om

Sterili
PAG E 34

zation

Written for engineers, by engineers


More and more, business in the Chemical Process Industries (CPI) is not local, its global. To keep up with this rapidly evolving marketplace, you need a magazine that covers it all, not just one country or region, not just one vertical market, but the whole CPI. With editorial ofces in Europe, Asia, and North America, CHEMICAL ENGINEERING is well-positioned to keep abreast of all the latest innovations in the equipment, technology, materials, and services used by process plants worldwide. No other publication even comes close.

PAG

E 34

Heat Hydro

Rever se Osmo sis Transf er Fluids

car Proper bon ties

Facts Lesson System s-Learned s

Focus on Filtrat ion

Preven

at You r Finger tips: Valve s ting Cakin g

The #1 choice of worldwide CPI organizations

To subscribe, please call 1-847-564-9290 or visit [email protected]

www.che.com
74
Chemical Engineering www.che.com September 2012

Economic Indicators

BUSINESS NEWS
PLANT WATCH
Air Products to build worlds largest energy-from-waste facility in the U.K. August 7, 2012 Air Products (Lehigh Valley, Pa.; www.airproducts.com) plans to build and operate a renewable energy plant in the U.K. using advanced-gasification energy-from-waste (EfW) technology.The Tees Valley plant, located at the New Energy and Technology Business Park, near Billingham, Teesside, is said to be the first of its kind in the U.K., and the largest of its kind anywhere in the world with an approximate capacity of 50 MW. Air Products has secured the necessary environmental and planning approvals, and the renewable energy facility is scheduled to enter commercial operation in 2014. Cobalt and Rhodia to build biobutanol demonstration plant in Brazil August 1, 2012 Cobalt Technologies (Cobalt; Mountain View, Calif.; www.cobalttech. com) and Rhodia, a member of the Solvay Group (Brussels, Belgium; www.solvay.com), will begin joint development and operation of a biobutanol demonstration facility in Brazil.This is a step toward the construction of commercial-scale biorefineries using Cobalts technology to convert Brazilian bagasse and other local non-food feedstock into bio-n-butanol. Operational testing at the demonstration plant is expected to be completed by mid-2013. BASF and Sinopec to explore building a world-scale isononanol plant in Maoming July 31, 2012 BASF SE (Ludwigshafen, Germany; www.basf.com) and China Petroleum & Chemical Corp. (Sinopec; www. sinopec.com) have signed a memorandum of understanding (MoU) to jointly explore the possibility of building an isononanol (INA) plant in Maoming Hi-tech Industrial Development Zone, Maoming, China.The final scope of the investment will be determined following the outcome of the joint feasibility study, which is expected by the end of 2012. Under the terms of the MoU, the two parties will evaluate the viability of jointly owning and operating a world-scale facility for the production of INA under a 5050 joint venture (JV) agreement. Novasep invests 3 million to boost its HPAPI manufacturing capabilities July 19, 2012 Novasep (Pompey, France; www.novasep.com) has announced a 3-million ($3.7 million) investment to expand its highly potent, active-pharmaceutical ingredients (HPAPI) manufacturing capabilities at its facility in Le Mans, France. In the new facility, Novasep will be able to perform cryogenic chemistry at 60C in Hastelloy reactors, large-scale HPLC chromatography and drying in confined areas to manufacture antibody-drug conjugates (ADC) toxins at commercial scale.The plant expansion is expected to be fully operational by the beginning of 2013. Uhde Inventa-Fischer to construct a polyamide 6 plant in China July 18, 2012 Uhde Inventa-Fischer (Berlin, Germany and Domat/Ems, Switzerland; www.uhde-inventa-fischer.com) and Changle Highsun Synthetic Fiber Technology Co. have signed a contract for the supply of a polymerization plant to produce high-performance polyamide 6 for textile applications.The multi-line plant will have an overall production capacity of 180,000 metric tons per year (m.t./yr) and will be located in Binhai Industrial Zone, Changle City, Fujian Province, China. Operation of the plant will be based on Uhde InventaFischers High-Performance Polyamide 6 technology (HPPA). Teijin to expand dimethyl terephthalate supply capability July 17, 2012 Teijin Ltd. (Tokyo; www.teijin. co.jp) says it will expand its supply capability for dimethyl terephthalate (DMT), a petrochemical used as a raw material in producing polyethylene terephthalate (PET) and for other specialty chemical applications.The companys existing DMT production facility at the Matsuyama Factory in Ehime Prefecture, Japan, will add a new line that processes DMT into high-purity briquettes. Capital expenditure for the expansion will be approximately one billion yen. Construction will begin in October, with operations scheduled to begin in April 2013. The expansion will enable Teijin to double its annual supply capability for DMT from the current 50,000 tons to 100,000 tons. Linde to construct two air-separation units for Tata Steel July 16, 2012 The Linde Group (Munich, Germany; www.linde.com) will be investing 80 million ($98.8 million) to construct two air-separation units (ASUs) at the Kalinganagar industrial complex in Odisha, India, for Tata Steel Ltd.The two companies recently signed an agreement to this effect.The air separation units are part of a long-term, onsite-gases supply contract for a new integrated steelworks that Tata is currently building in Kalinganagar. Each of the two new ASUs will be capable of producing 1,200 m.t./d of air gases. Once they go onstream in 2014, the units will supply gaseous oxygen, nitrogen and argon.Tatas new blast-furnace-based steel plant is also set to go onstream in 2014. It will initially produce 3 million m.t./yr.The company aims to increase capacity in the medium term to 12 million m.t./yr.

MERGERS AND ACQUISITIONS


Teijin to establish polyester chemical recycling JV in China August 8, 2012 Teijin Ltd. plans to establish Zhejiang Jiaren New Materials Co., Ltd., a JV with Jinggong Holding Group (Shaoxing, Zhejiang Province, China; www. jgsteelgroup.com).Through the JV,Teijin will chemically recycle polyester, as well as manufacture and sell the resulting fibers. The JV to which Teijin will contribute 49% and Jinggong Holding Group will contribute 51% will invest around 6 billion (about $76 million) in the construction of facilities for DMT production, polymerization and fiber spinning.The construction will begin this November, with operations scheduled to begin by the end of March, 2014. AkzoNobel signs agreement to sell its shares in ICI Pakistan July 30, 2012 AkzoNobel (Amsterdam, the Netherlands; www.akzonobel.com) has reached an agreement to sell its 75.81% shareholding in ICI Pakistan Ltd. to the Yunus Brothers Group for $152.5 million (124.4 million).The price is subject to adjustments.The transaction is expected to be completed toward the end of this year, once regulatory approvals have been obtained and the purchaser has completed a legally required tender offer for at least 50 % of the shares in ICI Pakistan held by the other shareholders. Fluor forms joint venture with Brazils Construcap July 23, 2012 Fluor Corp. (Irving,Tex.; www. fluor.com) has formed a new JV with CFPS Engenharia e Projetos, S.A. (Construcap; Sao Paulo, Brazil; www.construcap.com.br), to pursue engineering, procurement and construction management (EPCM) projects in Brazil. Financial terms of the JV were not disclosed. Dorothy Lozowski

FOR ADDITIONAL NEWS AS IT DEVELOPS, PLEASE VISIT WWW.CHE.COM


September 2012; VOL. 119; NO. 9 Chemical Engineering copyright @ 2012 (ISSN 0009-2460) is published monthly, with an additional issue in October, by Access Intelligence, LLC, 4 Choke Cherry Road, 2nd Floor, Rockville, MD, 20850. Chemical Engineering Executive, Editorial, Advertising and Publication Ofces: 88 Pine Street, 5th Floor, New York, NY 10005; Phone: 212-621-4674, Fax: 212-621-4694. Subscription rates: $149.97 U.S. and U.S. possessions, $166.97 Canada, and $269 International. $20.00 Back issue & Single copy sales. Periodicals postage paid at Rockville, MD and additional mailing ofces. Postmaster: Send address changes to Chemical Engineering, Fulllment Manager, P .O. Box 3588, Northbrook, IL 60065-3588. Phone: 847-564-9290, Fax: 847-564-9453, email: [email protected]. Change of address, two to eight week notice requested. For information regarding article reprints, please contact Wrights Media, 1-877-652-5295, [email protected]. Contents may not be reproduced in any form without written permission. Canada Post 40612608. Return undeliverable Canadian Addresses to: PitneyBowes, P .O. BOX 25542, LONDON, ON N6C 6B2 FOR MORE ECONOMIC INDICATORS, SEE NEXT PAGE

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

75

Economic Indicators

2010

2011

2012

DOWNLOAD THE CEPCI TWO WEEKS SOONER AT WWW.CHE.COM/PCI CHEMICAL ENGINEERING PLANT COST INDEX (CEPCI)
650

(1957-59 = 100)

CE Index
Equipment Heat exchangers & tanks Process machinery Pipe, valves & fittings Process instruments Pumps & compressors Electrical equipment Structural supports & misc Construction labor Buildings Engineering & supervision

June '12 Prelim. 585.5 713.9 661.4 666.5 917.7 425.1 927.0 513.7 759.9 322.5 527.2 327.9

May '12 Final 593.8 726.2 683.6 680.1 926.7 428.9 928.1 515.2 763.8 322.9 527.7 328.3

June '11 Final 588.9 718.0 678.0 664.5 904.8 440.9 904.7 510.8 760.7 325.6 519.1 332.6

Annual Index: 2004 = 444.2 2005 = 468.2

600

550

2006 = 499.6 2007 = 525.4


500

2008 = 575.4 2009 = 521.9 2010 = 550.8 2011 = 585.7


400 450

CURRENT BUSINESS INDICATORS


CPI output index (2007 = 100) CPI value of output, $ billions CPI operating rate, % Producer prices, industrial chemicals (1982 = 100) Industrial Production in Manufacturing (2007=100) Hourly earnings index, chemical & allied products (1992 = 100) Productivity index, chemicals & allied products (1992 = 100)

LATEST
Jul. '12 Jun. '12 Jul. '12 Jul. '12 Jul. '12 Jul. '12 Jul. '12 = = = = = = = 87.9 2,065.5 75.9 295.4 95.0 158.7 103.8 Jun. '12 May. '12 Jun. '12 Jun. '12 Jun. '12 Jun. '12 Jun. '12 = = = = = = =

PREVIOUS
87.8 2,116.1 75.8 312.7 94.5 157.1 104.6 May. '12 Apr. '12 May. '12 May. '12 May. '12 May. '12 May. '12 = = = = = = = 87.9 2,132.6 76.0 324.4 94.0 157.6 104.1

YEAR AGO Jul. '11 Jun. '11 Jul. '11 Jul. '11 Jul. '11 Jul. '11 Jul. '11 = = = = = = = 87.6 2,104.6 75.6 338.6 90.4 159.1 108.0

CPI OUTPUT INDEX (2007 = 100)


120 2500

CPI OUTPUT VALUE ($ BILLIONS)


85

CPI OPERATING RATE (%)

110

2200

80

100

1900

75

90

1600

70

80

1300

65

70

1000

60

J F M A M J J A S O N D

J F M A M J J A S O N D

J F M A M J J A S O N D

Current Business Indicators provided by IHS Global Insight, Inc., Lexington, Mass.

CURRENT TRENDS
apital equipment prices, as reflected in the CE Plant Cost Index (CEPCI; top), dropped 0.6% from May to June (the most recent data). Meanwhile, the Current Business Indicators from IHS Global Insight (middle), including the operating rate, changed very little from June to July. Meanwhile, according to the American Chemistry Councils (ACC; Washington, D.C.; www.americanchemistry.com) latest weekly economic report at CE press time, the Organization for Economic Cooperation and Development (OECD) composite leading indicator (CLI) for June and other data continue to point to an easing of economic activity in most major OECD econo-

mies and slowdowns in most major non-OECD economies. The June CLIs for China and India continued to point to a slowdown, and that for Russia suggests that it, too, may be headed toward a slowdown, the ACC report said. Brazil, on the other hand, appeared to be set for a moderate pickup in economic activity. The OECD CLI is designed to provide early signals of turning points between expansions and slowdowns in economic activity. The reading for the OECD countries plus Brazil, China, India, Indonesia, Russian Federation and South Africa showed a 0.1% decline in June, the ACC report said. It was the third consecutive monthly decline.

76

CHEMICAL ENGINEERING WWW.CHE.COM SEPTEMBER 2012

Learn valuable information relevant to your daily work without having to leave your desk!
ChemInnovations and Chemical Engineering Magazine are excited to present eLearning On Demand. This new feature allows you the convenience of watching online courses anytime, anywhere, and at your own pace. 2 hour courses start at $49. Receiving educational training has never been easier! Visit www.cpievent.com/elearning and use promo codeTRIALto view a free trial of ChemInnovations 2011 Keynote Presentation U.S. Oil, Natural Gas, and Natural Gas Liquids (NGL) Outlook and its Impact on the Chemical Industry by 2020.

OUR INDUSTRY EXPERTS COVER DOZENS OF TOPICS INCLUDING:


Global Energy Outlook Regulatory Issues Process, Design and Operations EH & S Equipment Maintenance Equipment Reliability Instrumentation Controls Automation And more

Visit the BRAND NEW eLearning On Demand site and enjoy the luxury of receiving training without leaving the office!

www.cpievent.com/elearning

Our safety experts talk safety. Our operators talk control. But when it comes to keeping our people and plant safe, we all need to speak the same language.

YOU CAN DO THAT


Eliminate uncertainty, reduce your risk with DeltaV SIS. Emersons smart safety instrumented system provides an integrated, intuitive set of engineering tools and software that enables your team to handle configuration, alarms and device health monitoringwhile maintaining the systems separation required by IEC 61511 and 61508 standards. The DeltaV SIS system reduces your training and lifecycle costs by eliminating complex data-mapping and multiple databases while helping to ensure that youre meeting safety compliance. Learn more about safety processes and best practices by downloading the Safety Lifecycle Workbook at: www.DeltaVSIS.com/workbook

The Emerson logo is a trademark and a service mark of Emerson Electric Co. 2012 Emerson Electric Co.