0% found this document useful (0 votes)
105 views1 page

Ajuste de Parámetros Especiales: Variador de Frecuencia Powerflex 400

This document provides descriptions and default settings for various parameters of a PowerFlex 400 variable frequency drive. It lists the basic display group parameters including output frequency, motor nameplate voltage and hertz, minimum and maximum frequency, start and stop modes, and speed reference. It also lists advanced program parameters such as PID reference selection, proportional gain, setpoint, preload, auto restart tries, delay, and whether to start at power up.

Uploaded by

Andres Zuñiga
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
105 views1 page

Ajuste de Parámetros Especiales: Variador de Frecuencia Powerflex 400

This document provides descriptions and default settings for various parameters of a PowerFlex 400 variable frequency drive. It lists the basic display group parameters including output frequency, motor nameplate voltage and hertz, minimum and maximum frequency, start and stop modes, and speed reference. It also lists advanced program parameters such as PID reference selection, proportional gain, setpoint, preload, auto restart tries, delay, and whether to start at power up.

Uploaded by

Andres Zuñiga
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

Ajuste de parmetros especiales

Variador de frecuencia PowerFlex 400 Parmetro Descripcin Ajuste Referencia

Basic Display group b001 Output freq Basic Program P031 P032 P033 P034 P035 P036 P037 P038 P042 Motor NP Volts Motor NP Hertz Motor OL Current Minimun frequency Maximun frequency Start Source Stop mode Speed reference Auto mode Terminal Block T055 T073 T074 T075 T076 Relay Out 1 Sel Analog In 2 sel Analog In 2 lo Analog In 2 Hi Analog In 2 loss 0 1 0% 100% 2 Advanced Program A152 A154 A157 A159 A163 A164 A165 PID Ref Sel PID Prop Gain PID Setpoint PID Preload Auto restart tries Auto restart delay Start at power up 3 3.45 66% 30 Hz 9 15 1 Tries to restart time to try restart Enable Analog Input 2 Stop Ready/fault Current mode (4-20mA) 230V 60 Hz 35 A 20 Hz 65 Hz 2 1 3 3 Two wires Coast stop Analog In 2 Auto/manual Solo visualizacin