Optix RTN 600 Microwave Acceptance Test
ACCEPTANCE TEST DATA MICROWAVE RADIO SYSTEM OPTIX RTN 600
STATION A STATION B
: :
______________________________ ______________________________
Provided by: ___________________ Approved by:___________________
Date:__________________ _ Date:__________________ _
Optix RTN 600 Microwave Acceptance Test
CONTENT :
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15.
Visual Check Configuration Check Loop Back Test (Local and remote) Receive Power Level Result Protection Switching Test Interference Check Power Voltage Check Clock Setting Check Network Configuration Ethernet Service Connectivity Terminal Inventory Check Browse Alarm Check ATPC Test BER Test Measurement Attachment BER Test Result
Optix RTN 600 Microwave Acceptance Test
1)
Visual Check
1) Serial Number Station: A _________________________________________ UNIT IDU ODU 1 ODU 2(*) Hybrid(*) Antenna (*) Fit only applicable Cell and if equipped Station: B _________________________________________ UNIT IDU ODU 1 ODU 2(*) Hybrid(*) Antenna (*) Fit only applicable Cell and if equipped 2Antenna Antenna Station:A ___________________ Station: B ___________________ Diameter (M) Height (M) Polarization Vertical Horizontal Vertical Horizontal Item Check 3) 4) 5) 6) 7) Check the physical Out-door installation. Check the Radio indoor equipment installation. Indoor Cable rack and structure installation. Labeling. Grounding cable installation OK NOK Serial No Serial No
Optix RTN 600 Microwave Acceptance Test
2)
Configuration Check
Station A Set-Up Transmitted frequency Received frequency Frequency Plan (*) Sub Band Transmitted power requested dBm Channel 1 (MHz) (MHz) (MHz) dBm dBm Channel 2 (MHz) (MHz) (MHz) dBm Channel 1 (MHz) (MHz) (MHz) Channel 2 (MHz) (MHz) (MHz)
(*) Only in case of Frequency plan setting Station B Set-Up Transmitted frequency Received frequency Frequency Plan (*) Seb Band Transmitted power requested (*) Only in case of Frequency plan setting
3. Loop Back Test (Local and remote)
Loop Back Test Station A Station B Local Tributary OK NOK Local Tributary OK NOK
4. Receive Power Level Result
Item Rx level in link budget Rx Level Tx Power (**) if Applicable Station A ODU 1 dBm dBm dBm ODU 2 (**) dBm dBm dBm ODU 1 dBm dBm dBm Station B ODU 2 (**) dBm dBm dBm
5. Protection Switching Test
System Type : 1+1HSB 1+1FD 1+1SD Site Station A Station B Switching Result OK NOK NA(*) OK NOK NA(*)
Optix RTN 600 Microwave Acceptance Test
(*) if the configuration only 1+0 This test includes BER Test measurement to check the following: No errors on F/D and S/D Protection Switching Test Errors on HSB Protection Switching Test.
6. Interference Check
Item Receive Level (*) (*) Receive power level <-80db no interference affect on link -79dB<receive power level <-74dB, refer to BER test, no error in BER test no interference affect on link Receive power level >-74dB interference on link. (**) If applicable Station A (Tx Off on B) ODU 1 ODU 2 (**) Station B (Tx Off on A) ODU 1 ODU 2 (**)
7. Power Voltage Check
Station name Station A Station B Power Supply Voltage [+ [+ ] Volt ] Volt
8. Clock Setting Check
Site Station A Station B Clock Setting Result OK NOK NA OK NOK NA
9. Network Configuration
NE ADDRESS Station Name Name : NE ID IP Address Net Mask Station A Name : Station B
10. Ethernet Service Connectivity
Site Station A Station B (*)If board not available on IDU Ethernet Test Result OK NOK NA(*) OK NOK NA(*)
Optix RTN 600 Microwave Acceptance Test
11. Terminal Inventory Station A
Equipment Checking PXC PXC SCC EOW IF1 IF1 IF1 IF1 SL1 SD1 PO1 PH1 PD1 FAN SDE SLE Slot Position Board Style Board Barcode
Station B
Equipment Checking PXC PXC SCC EOW IF1 IF1 IF1 IF1 SL1 SD1 PO1 Slot Position Board Style Board Barcode
Optix RTN 600 Microwave Acceptance Test
PH1 PD1 FAN SDE SLE
12. Browse Alarm Check
Check Item Alarm test, including ODU and IDU sections Station A OK NOK Station B OK NOK
13. ATPC Test tem Check
Tx nominal power (dBm) ATPC Range - PTX Min Value (dBm) ATPC Range - PTX Max Value (dBm) ATPC Rx Threshold - Low Power (dBm)
Station A
Station B
14. BER Test Measurement
SETUP No errors (*) Main Channel OK NOK
(*) Value applicable in normal propagation condition (*) All Background BER Test, applicable only in normal propagation condition for 30-60min
15. Stick printed copy of BER test result.
Attachment BER Test Result at the site for 30-60min
Optix RTN 600 Microwave Acceptance Test
24h Performance test by NMS in NMC/NOC (Test to be done after ATP)