Nehon ECG
Nehon ECG
Nehon ECG
Clear viewing 12.1-inch touch panel TFT LCD with swivel screen
Better patient care with swivel screen A flexible arm lets you change the screen angle to the best viewing position to help the care giver.
DESIGN FEATURES
Swivel screen
12.1 inch touch panel TFT LCD with swivel screen lets you change the screen angle to the best viewing position.
Serial comparison
Average waveforms in the latest 5 exams can be compared in the same screen. You can know the changes in time-series basis.
Communication capability
Approximately 400 patients x 10 seconds of 12 lead ECG wave and patient information can be stored. Approximately 2,500 patients x 10 seconds of 12 lead ECG wave and patient information can be stored on a QM-040V flash disk card. Stored data can be transferred to PC via QM-040V or LAN/ Wireless LAN interface with optional QB903E ECG viewer software.
The most recent five minutes of all lead ECG waveforms can be stored in memory. This increases the chance to record important data. To save paper, you can select, analyze and print just the necessary region from 5 minute full disclosure.
You can create files of resting 12-lead ECG and analysis from selected data
Specifications
ECG Input
Input impedance: 10 M Electrode offset tolerance: 400mV Input unit protection: Isolated and defibrillation protected Standard sensitivity: 10 mm/mV 5% Common mode rejection ratio: 110 dB or less Frequency response: 0.05 Hz to 150 Hz, -3 dB (drift filter:off,High-cut filter:150 Hz)
Safety
Safety standard: IEC60601-1 (1988),IEC60601-1 Amendment 1 (1991),IEC60601-1 Amendment 2 (1995),IEC60601-2-25 (1993),IEC60601-2-25 Amendment 1 (1999),IEC60601-1-1 (2000) Type of protection against electric shock: AC power:Class I Battery power:Internally powered equipment Degree of protection against electric shock: Defibrillator proof type CF applied part when input box JC901D is used
Power Requirements
Line voltage: 100 to 127V,220 to 240 V 10% Line frequency: 50/60Hz Power input: ECG-1500K:50 VA,ECG-1550K:150 VA Power saving: Standby mode
Display
Type: Color LCD (with backlight) Display size: 12.1 inch Resolution: 800 x 600 dots Displayed data: Waveform,patient information,recording settings,operation mode
Electromagnetic Compatibility
IEC60601-1-2 Second edition 2001 IEC60601-2-25 Amendment 1:1999
Environment
Main Unit: Operating temperature: 10 to 40C Operating humidity: 25 to 95% RH Operating atmospheric pressure: 70 to 106 kPa Storage temperature: -20 to 65C Storage humidity: 10 to 95% RH (non condensing) Battery: Operating humidity: 45 to 85% RH Storage temperature: 30 days or less:-20 to 50C one year or less:-20 to 30C Storage humidity: 60 days or less:10 to 95% RH more than 60 days:45 to 85% RH Recording paper: Operating humidity:25 to 80% RH Storage temperature:-20 to 50C Storage humidity: 10 to 90% RH
Recorder (ECG-1550K)
Printing process: High resolution thermal print head Printing density: 200 dpi (8 dots/mm) Scanning line density: 1 ms Number of channels: 3,4,6,7,12 Paper speed: 5,10,12.5,25,50 mm/s Recording data: Program type,version,date and time, paper speed,sensitivity,lead name,filter,hospital name, patient information,electrode detachment,noise Recording paper type: 210 mm width,30 m long Zfold (100 m or 300 m Z-fold and roll recording paper set outside the main unit)
ECG Analysis
Program name: ECAPS 12C Analysis patient age: 3 years to adult Finding items: approx.200 Judging items: 5
Performance
Performance standard: IEC60601-2-51(2003)
This device is intended for use only by qualified medical personnel. This brochure may be revised or replaced by Nihon Kohden at any time without notice.
NIHON KOHDEN AMERICA, INC. Icon Street, Foothill Ranch, CA 92610 (800) 325-0283 (949) 580-1555 Fax: (949) 580-1550 www.nkusa.com