0% found this document useful (0 votes)
120 views2 pages

Tutorial Problems On Mtodule-3

The document contains three power flow analysis problems: 1. For a 5 bus system, calculate the bus admittance (Y) matrix given the line impedance and charging data. 2. For a 3 bus system with two generators, calculate the generator outputs at buses 1 and 2, as well as the voltage magnitude and angle at bus 3. 3. For a 3 bus system with one slack bus, one PV bus, and one PQ bus, calculate the power flow solution given the generator output at bus 2 and the load at bus 3.

Uploaded by

stackzzz
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
120 views2 pages

Tutorial Problems On Mtodule-3

The document contains three power flow analysis problems: 1. For a 5 bus system, calculate the bus admittance (Y) matrix given the line impedance and charging data. 2. For a 3 bus system with two generators, calculate the generator outputs at buses 1 and 2, as well as the voltage magnitude and angle at bus 3. 3. For a 3 bus system with one slack bus, one PV bus, and one PQ bus, calculate the power flow solution given the generator output at bus 2 and the load at bus 3.

Uploaded by

stackzzz
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Tutorial Problems on Module-3 Power Flow Analysis Problem-1 For the system given below, find the Y-Bus

matrix. All line data are in per unit.


G 1 3 G 4

2 G

Table-1: Line Data (all data are in pu) Line Impedance, Line i-j Zij Charging yij 1-2 0.02 + j 0.06 j0.03 1-3 0.08 + j0.24 j0.025 2-3 0.06 + j0.18 j0.02 2-5 0.04 + j0.12 j0.015 3-4 0.01 + j0.03 j0.10 4-5 0.08 + j0.24 j0.025

Problem-2 For the system in the figure below, find the generator outputs at bus-1 and bus-2, in per unit. Also determine the bus-3 voltage magnitude |V3| the corresponding angle 3. Given that both the transmission lines have equal impedances of 0.1 per unit. Other parameters are given alongside the figure.

10

1.050

j 0.1

j 0.1

V3d3

0.9+j 0.4

Problem-3 Consider the system shown in the figure below. Bus #1 and Bus #2 have generators connected to them while Bus #3 has a load connected to it, as shown. We shall consider Bus #1 to be the slack bus. Also we know that Bus #2 is a PV bus and Bus #3 is a PQ bus. It is also given that the generation from Gen-2 is 0.6661 p.u.

G V1=1.0 0 o 1

G PG2 = 0.6661 p.u. |V2 |=1.05 2

3 2.8653+j1.2244 p.u.

All transmission lines admittances are equal, and line charging susceptances are equal, as follows: y12 = -j10; b12 = j0.02; y13 = -j10; b13 = j0.02; y23 = -j10; b23 = j0.02; Find the power flow solution of the given system.