ODIN Meter An Electricity Energy Meter From ABB: Technical Documentation
ODIN Meter An Electricity Energy Meter From ABB: Technical Documentation
ODIN Meter An Electricity Energy Meter From ABB: Technical Documentation
Technical documentation
ODIN Meter
Contents
General description .............................................................................................................. 2 OD4165 direct connection, 3 phase meter up to and including 65 A ............................... 3 OD4110 transformer connection, 3 phase meter ............................................................... 4 Accessories .......................................................................................................................... 5 Wiring diagrams ................................................................................................................... 6 Device dimensions ................................................................................................................ 7 Examples of connections ...................................................................................................... 8
ABB
ODIN Meter
General Description
ODIN Meter is a compact electricity energy meter made for measuring active electrical energy and designed to be mounted on a DIN rail in distribution boards or in standard cabinets. During the development process creating SIMPLICITY was the number one priority. The ODIN Meter shall be perceived as easy to install, use and distribute.
St375010
Examples of this can already be seen on the front of the electricity energy meter, clear marking, strong screws in the connecting terminal and an easy to read display. Enclosed in the carton are easy to understand instructions, which use text and diagrams to describe in detail how the installation should be carried out. The ODIN Meter is certified according to the international standard IEC 61036. The standard covers several technical requirements including climate, mechanics, electronics, EMC and accuracy. Furthermore the ODIN Meter has a national approval from Swedens Test and Research Institute (SP) as a revenue meter. This guarantees the ODIN Meter is highly reliable, has a long life expectancy and maintains its measuring accuracy.
ABB
ODIN Meter
OD4165 direct connection, 3 phase meter up to and including 65 A
Article number 2CMA131024R1000 Technical Data
St375010
Type OD4165
Voltage: Voltage range Max current Start current Power consumption of current circuits Frequency Accuracy of measurement Standard Temperature range Material of front cover Material of back cover Resistance to heat and fire Protection against penetration of dust and water Connection area in the current connecting terminals Pulse output Connection area in the connecting terminal External pulse voltage Max. current Pulse length Pulse frequency Standard LED Pulse frequency Pulse length Display 100 imp/kWh 40 ms LCD with 7 digits without a decimal place, 6 mm 0.5 2.5 mm2 5 40 V DC 100 mA 100 ms 2.5 ms 100 imp/kWh IEC 62053-1 (S0) 3x230/400 V AC -20% to +15% 65 A 25 mA < 3 VA/phase 50/60 Hz Class 2 (2%) IEC 61036 -25 to +55oC Polycarbonate Polycarbonate/glass fibre Equivalent to IEC 695-2-1 IP 20 1 16 mm2
Front view
Direct connection
Type description Wiring diagram
OD4165
LED frequency
St375004
Identification No.
ABB
ODIN Meter
OD4110 connection via external current transformers, 3 phase meter
Article number 2CMA131025R1000 Type OD4110 Voltage (V) 230/400V Pulse output frequency 1 imp./kWh
St375010
Technical Data Voltage: Voltage range Max. current Starting current Power consumption of current circuits Power consumption of voltage circuits Frequency Accuracy of measurement Standard Temperature range Programmable transformer ratios
3x230/400 V AC
-20% to +15% 10 A 15 mA < 0.02 VA/phase < 2 VA/phase 50/60 Hz Class 2 (2 %) IEC 61036 -25 to +55oC 5/5, 75/5, 100/5 150/5, 200/5, 250/5, 300/5, 400/5, 500/5, 600/5, 700/5 750/5, 800/5, 900/5 A/A Polycarbonate Polycarbonate/glass fibre Equivalent to IEC 695-2-1 IP 20 1 16 mm2 0.5 6 mm2
Material of front cover Material of back cover Resistance to heat and fire Protection against penetration of dust and water Connection area in the current connection terminal Connection area in the voltage connection terminal Pulse output Connection area in the connection terminal External pulse voltage Max. current Pulse length Pulse frequency Standard LED Pulse frequency Pulse length Display
0.5 2.5 mm2 5 40 V DC 100 mA 100 ms 2.5 ms 1 imp/kWh IEC 62053-1 (S0)
Front view
LED frequency
St375005
Identification No.
ABB
ODIN Meter
Accessories
Picture No.
2 3
09 809 50
Picture No. 2
45,5
St375003
106 161
Mt375003
Picture No. 3
160
St375001
180
175
ABB
80
92 Mt375001
ODIN Meter
Wiring diagrams
L1 L2 L3
St375006
P1 P1 P1
P1 S1
P2 S2
N PE
2 5 8
St375007
11
20 21
+ -
11
Pulse output
St375008
St375009
ABB
ODIN Meter
Device dimensions
Device dimensions
6.6
7.1
5.7
4,7
O 5.3
O 7.4
85
45
O 4.4
24.8 105
20
63,4
Mt375002
ABB
ODIN Meter
Examples of connections
The electricity meter will function correctly with the neutral connected to either the upper or lower terminal
ABB
ABB Automation Technology Products AB Cewe Box 1005 S-611 29 Nykping, Sweden Phone Int +46 155-29 50 00 Fax Int +46 155-28 81 10