0% found this document useful (0 votes)
111 views1 page

Steel Design: Project Job Number Engineer

The summary analyzes the structural design of a steel frame using AISC-LRFD93 standards. It describes Frame 1 with dimensions of 300cm x 0cm x 0cm and a length of 600cm. The design section is determined to be overstressed under the calculated forces and moments, with an axial force to capacity ratio of 1.345, exceeding the limit of 0.950.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
111 views1 page

Steel Design: Project Job Number Engineer

The summary analyzes the structural design of a steel frame using AISC-LRFD93 standards. It describes Frame 1 with dimensions of 300cm x 0cm x 0cm and a length of 600cm. The design section is determined to be overstressed under the calculated forces and moments, with an axial force to capacity ratio of 1.345, exceeding the limit of 0.950.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SAP2000 Steel Design

Project Job Number Engineer

AISC-LRFD93 STEEL SECTION CHECK Combo : UDSTL2 Units : Kgf, cm, C

Frame X Mid Y Mid Z Mid Length Loc Area IMajor IMinor Ixy Theta

: : : : : : : : : : :

1 300.000 0.000 0.000 600.000 40.000 2.319 3.237 3.237 -1.925 45.000

Design Sect: Design Type: Frame Type : Sect Class : Major Axis : RLLF : SMajor SMinor ZMajor ZMinor : : : :

L.LONG Beam Moment Resisting Frame Non-Compact 0.000 degrees counterclockwise from local 3 1.000 rMajor rMinor rMax rMin : : : : 1.182 1.182 1.492 0.752 AVMajor: AVMinor: E : Fy : 1.210 1.210 2100000.000 2530.000

1.181 1.181 2.128 2.128

DESIGN MESSAGES Error: Section overstressed STRESS CHECK FORCES & MOMENTS Location Pu 40.000 97.711 PMM DEMAND/CAPACITY RATIO Governing Total Equation Ratio (SAM 6-1b) 1.345 AXIAL FORCE DESIGN Axial MOMENT DESIGN Major Moment Minor Moment SHEAR DESIGN Major Shear Minor Shear Vu Force 117.067 0.000 phi*Vn Capacity 1652.658 1652.658 Stress Ratio 0.071 0.000 Status Check OK OK Tu Torsion 0.000 0.000 Mu Moment 2186.821 -2186.821 phi*Mn Capacity 4865.629 2468.631 Cm Factor 1.000 1.000 B1 Factor 1.000 1.000 B2 Factor 1.000 1.000 K Factor 1.000 1.000 L Factor 0.067 0.067 Cb Factor 1.000 Pu Force 97.711 phi*Pnc Capacity 4344.114 phi*Pnt Capacity 5279.324 Mu33 3092.632 P Ratio 0.009 Mu22 0.000 MMajor Ratio 0.449 Vu2 -117.067 MMinor Ratio 0.886 Vu3 0.000 Ratio Limit 0.950 Tu 0.000 Status Check Overstress

SAP2000 v14.0.0 - File:E:\Acuedutos Metalicos\Ac_Huayopata\Estructura 4 SAP rectangular L=7 m de luz\ACUEDUCTO 4 MARAMPAQUI__8m_=160

marzo 26, 2013 16:56