AMD Athlon™ 64 Processor
AMD Athlon™ 64 Processor
51 March 2006
rights reserved.
The contents of this document are provided in connection with Advanced Micro Devices, Inc. (AMD) products. AMD makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. The information contained herein may be of a preliminary or advanced nature and is subject to change without notice. No license, whether express, implied, arising by estoppel or otherwise, to any intellectual property rights is granted by this publication. Except as set forth in AMDs Standard Terms and Conditions of Sale, AMD assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. AMDs products are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or in any other application in which the failure of AMDs product could create a situation where personal injury, death, or severe property or environmental damage may occur. AMD reserves the right to discontinue or make changes to its products at any time without notice.
Trademarks AMD, the AMD Arrow logo, AMD Athlon, AMD Sempron, AMD Turion, and combinations thereof are trademarks of Advanced Micro Devices, Inc. HyperTransport is a licensed trademark of the HyperTransport Technology Consortium. Other product names used in this publication are for identification purposes only and may be trademarks of their respective companies.
Contents
1 AMD Athlon 64 Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 1.1 Ordering Part Number Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 1.2 AMD Athlon 64 Processor BIOS Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 1.3 AMD Athlon 64 Processor Thermal/Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 30 AMD Athlon 64 FX Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 2.1 Ordering Part Number Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 2.2 AMD Athlon 64 FX Processor BIOS Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 2.3 AMD Athlon 64 FX Processor Thermal/Power Specifications . . . . . . . . . . . . . . . . . . . . . . . 56 AMD Sempron Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 3.1 Ordering Part Number Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 3.2 AMD Sempron Processor BIOS Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 3.3 AMD Sempron Processor Thermal/Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 AMD Turion 64 Mobile Technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 4.1 Ordering Part Number Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 4.2 AMD Turion 64 Mobile Technology BIOS Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 77 4.3 AMD Turion 64 Mobile Technology Thermal/Power Specifications . . . . . . . . . . . . . . . . . . 80 AMD Athlon 64 X2 Dual Core Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 5.1 Ordering Part Number Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 5.2 AMD Athlon 64 X2 Dual Core Processor BIOS Specifications . . . . . . . . . . . . . . . . . . . . . . 87 5.3 AMD Athlon 64 X2 Dual Core Processor Thermal/Power Specifications . . . . . . . . . . . . . . 91 MTOPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Contents
List of Figures
Figure 1. AMD Athlon 64 Processor Ordering Part Number Example . . . . . . . . . . . . . . . . . . . . . .8 Figure 2. AMD Athlon 64 FX Processor Ordering Part Number Example . . . . . . . . . . . . . . . . . .49 Figure 3. AMD Sempron Processor Ordering Part Number Example . . . . . . . . . . . . . . . . . . . . .60 Figure 4. AMD Turion 64 Mobile Technology Ordering Part Number Example . . . . . . . . . . . . .75 Figure 5. AMD Athlon 64 X2 Dual Core Processor Ordering Part Number Example . . . . . . . . .84
List of Figures
List of Tables
Table 1: Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Table 2: AMD Athlon 64 Processor Part Definition Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Table 3: AMD Athlon 64 Processor L2 Cache Size Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Table 4: AMD Athlon 64 Processor Temperature Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Table 5: AMD Athlon 64 Processor Operating Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Table 6: AMD Athlon 64 Processor Package Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Table 7: AMD Athlon 64 Processor Model Number Options . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Table 8: AMD Athlon 64 Processor Thermal Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Table 9: AMD Athlon 64 Processor BIOS Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Table 10: AMD Athlon 64 Processor Thermal/Power Specifications . . . . . . . . . . . . . . . . . . . . . .30 Table 11: AMD Athlon 64 FX Processor Part Definition Options . . . . . . . . . . . . . . . . . . . . . . . . .49 Table 12: AMD Athlon 64 FX Processor L2 Cache Size Options . . . . . . . . . . . . . . . . . . . . . . . . .50 Table 13: AMD Athlon 64 FX Processor Temperature Options . . . . . . . . . . . . . . . . . . . . . . . . . .50 Table 14: AMD Athlon 64 FX Processor Operating Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 Table 15: AMD Athlon 64 FX Processor Package Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 Table 16: AMD Athlon 64 FX Processor Model Number Options . . . . . . . . . . . . . . . . . . . . . . . .50 Table 17: AMD Athlon 64 FX Processor Thermal Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 Table 18: AMD Athlon 64 FX Processor BIOS Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . .52 Table 19: AMD Athlon 64 FX Processor Thermal/Power Specifications . . . . . . . . . . . . . . . . . . .56 Table 20: AMD Sempron Processor Part Definition Options . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 Table 21: AMD Sempron Processor L2 Cache Size Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 Table 22: AMD Sempron Processor Temperature Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 Table 23: AMD Sempron Processor Operating Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 Table 24: AMD Sempron Processor Package Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 Table 25: AMD Sempron Processor Model Number Options . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 Table 26: AMD Sempron Processor BIOS Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 Table 27: AMD Sempron Processor Thermal/Power Specifications . . . . . . . . . . . . . . . . . . . . . . .68 Table 28: AMD Turion 64 Mobile Technology Part Definition Options . . . . . . . . . . . . . . . . . . . .75 Table 29: AMD Turion 64 Mobile Technology L2 Cache Size Options . . . . . . . . . . . . . . . . . . . .76 Table 30: AMD Turion 64 Mobile Technology Temperature Options . . . . . . . . . . . . . . . . . . . . .76 Table 31: AMD Turion 64 Mobile Technology Operating Voltage . . . . . . . . . . . . . . . . . . . . . . . .76 Table 32: AMD Turion 64 Mobile Technology Package Options . . . . . . . . . . . . . . . . . . . . . . . . .76 Table 33: AMD Turion 64 Mobile Technology Model Number Options . . . . . . . . . . . . . . . . . . .76 Table 34: AMD Turion 64 Mobile Technology Power Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . .76 Table 35: AMD Turion 64 Mobile Technology BIOS Specifications . . . . . . . . . . . . . . . . . . . . . .77
List of Tables
Table 36: AMD Turion 64 Mobile Technology Thermal/Power Specifications . . . . . . . . . . . . . .81 Table 37: AMD Athlon 64 X2 Dual Core Processor Part Definition Options . . . . . . . . . . . . . . . .84 Table 38: AMD Athlon 64 X2 Dual Core Processor L2 Cache Size Options . . . . . . . . . . . . . . . .84 Table 39: AMD Athlon 64 X2 Dual Core Processor Temperature Options . . . . . . . . . . . . . . . . . .85 Table 40: AMD Athlon 64 X2 Dual Core Processor Operating Voltage . . . . . . . . . . . . . . . . . . . .85 Table 41: AMD Athlon 64 X2 Dual Core Processor Package Options . . . . . . . . . . . . . . . . . . . . .85 Table 42: AMD Athlon 64 X2 Dual Core Processor Model Number Options . . . . . . . . . . . . . . . .85 Table 43: AMD Athlon 64 X2 Dual Core Processor Power Limit . . . . . . . . . . . . . . . . . . . . . . . . .85 Table 44: AMD Athlon 64 X2 Dual Core Processor Thermal Profile . . . . . . . . . . . . . . . . . . . . . .86 Table 45: AMD Athlon 64 X2 Dual Core Processor BIOS Specifications . . . . . . . . . . . . . . . . . .87 Table 46: AMD Athlon 64 X2 Dual Core Processor Thermal/Power Specifications . . . . . . . . . .91 Table 47: Composite Theoretical Performance (CTP) Calculations . . . . . . . . . . . . . . . . . . . . . . . . .95
List of Tables
Revision
3.51 3.47 3.43 3.41 3.37 3.29 3.25
Description
Added three AMD Turion 64 Mobile Technology OPNS: TMSMT32BQX4LD, TMSMT34BQX5LD, and TMSMT37BQX5LD. Added OPNs across all processor brands. Added new Section 5 AMD Athlon 64 X2 Dual Core Processor. Added new Section 6 MTOPS. Added OPN for model 4000+ desktop Added FX-55 OPN. Added desktop OPNs for models 3000+, 3200+, and 3500+. Documented TCONTROL max parameter for all OPNs. Removed chapters 3, 4, and 6. Added AMD Sempron Processor and Mobile AMD Sempron Processor chapters. Removed model 3100+ 62W OPN. Added DTR Model 3700+ OPN. Added model 3400+ 62W mobile OPN. Added rev CG 89W model 3500+, 3700+, and 3800+ OPNs. Added FX-53 939 pin package OPN. Added one decimal precision to some IDD numbers. Updated document references. Added rev CG 35W models 2700+ and 2800+. Removed rev CG 35W OPN. Corrected model number formatting for DTR OPNs. Added rev CG 35W model 2700+ OPN. Added rev CG model 2800+, 3000+, and 3200+ 89W OPNs. Added FX-53 940 pin package OPN. Corrected note for C3 state on all Power/Thermal Specification tables. Added package drawing references for lidless parts in OPN decode section. Added rev CG entries for existing rev C0 parts. Corrected Max FID code for model 3200+ 62W mobile OPN. Updated FX-51 Halt/Stop Grant power number. Revised IDD Max and TDP for Intermediate P-state #2 for 754 pin lidless package Rev C0 DTR Model 3200+. Added model 3400+ DT and DTR parts. Added model 2800+, 3000+, and 3200+ 62W Mobile parts. Added model 3000+ desktop part. General clean up. Updated S3 I/O power for non-FX parts. Fixed mobile OPN example. Added thermal resistance specifications for all OPNs. Changed min P-state information to N/A in Table 8, and removed unreleased entries from Table 4 and Table 14. Initial public release.
May 2004 April 2004 April 2004 March 2004 March 2004
January 2004
3.11
January 2004 December 2003 November 2003 September 2003 September 2003
The following sections contain thermal/power and related BIOS specifications for AMD Athlon 64 processors. Each column in the BIOS and thermal/power tables represents a specific Ordering Part Number (OPN). Section 1.1 provides an example of the OPN structure for this processor family. For all other electrical specifications for the processor, refer to the AMD Athlon 64 Product Data Sheet, order #24659. For power management BIOS requirements, refer to the BIOS and Kernel Developers Guide for AMD Athlon 64 Processors and AMD Opteron Processors, order #26094.
Part Definition: AP= Rev C0 (see Table 2) L2 Cache Size: 5= 1 Megabyte (see Table 3) Case Temperature: P= 70oC (see Table 4) Operating Voltage: E= 1.50 V (see Table 5) Package: A= 754 pin lidded OPGA (see Table 6) Model Number: 3200: see Table 7 Brand: AMD Athlon 64 Desktop
Figure 1. AMD Athlon 64 Processor Ordering Part Number Example Table 2: AMD Athlon 64 Processor Part Definition Options
Part Definition
AP AR AS AW AX BI BN BP BW
Revision
Rev C0 Rev CG Rev CG Rev CG Rev CG Rev D0 Rev E4 Rev E3 Rev E6
Package Drawing
Lidded Lidded D1 D1 Lidded D1 D1 D2 D2
Revision
Rev E6 Rev E6 Rev E4
Package Drawing
Lidded D1 D1
Note: Refer to the AMD Functional Data Sheet, 754 Pin Package, order #31410 or AMD Functional Data Sheet, 939 Pin Package, order #31411, as appropriate for package drawings.
Cache Size
256 KB 512 KB 1 MB
Temperature
Variable 69oC 70oC 65oC
Operating Voltage
Variable 1.50 V 1.40 V 1.35 V
Package
754 Pin Lidded OPGA 939 Pin Lidded OPGA
754 Pin Lidded OPGA 512 KB 754 Pin Lidded OPGA 512 KB 754 Pin Lidded OPGA 1 MB 754 Pin Lidded OPGA 512 KB 754 Pin Lidded OPGA 256 KB 754 Pin Lidded OPGA 1 MB 754 Pin Lidded OPGA 512 KB 754 Pin Lidded OPGA 1 MB 939 Pin Lidded OPGA 512 KB 939 Pin Lidded OPGA 512 KB 939 Pin Lidded OPGA 512 KB 939 Pin Lidded OPGA 512 KB 939 Pin Lidded OPGA 1 MB 939 Pin Lidded OPGA 512 KB 939 Pin Lidded OPGA 1 MB
Power Power (Thermal Profile A) (Thermal Profile B) 20.6 W 20.6 W 26.5 W 26.5 W 32.4 W 32.4 W 38.2 W 38.2 W 44.1 W 44.1 W 50.0 W 50.0 W 55.9 W 55.9 W 61.8 W 61.8 W 67.6 W 67.0 W 73.5 W N/A 79.4 W N/A 85.3 W N/A
Note: The thermal profile is used to define the relationship between Tcase max and device specific Thermal Design Power for Rev E processors specified in this document with Variable indicated by the Case Temperature OPN character.
10
3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
11
Parameter/OPN Model Number CPUID 8000_0001h EBX [11:6] (BrandID) CPUID 8000_0001h EAX [31:0] (CPUID) FID/VID Status MaxVID Field FID/VID Status MaxFID Field FID/VID Status StartVID Field FID/VID Status StartFID Field L2 Cache Size Max HyperTransport Frequency Max P-State VID Code VID_VDD Thermal Design Power Intermediate P-State #1 VID Code / VID_VDD Thermal Design Power Intermediate P-State #2 VID Code / VID_VDD Thermal Design Power Intermediate P-State #3 VID Code / VID_VDD Thermal Design Power Intermediate P-State #4 VID Code / VID_VDD Thermal Design Power Intermediate P-State #5 VID Code / VID_VDD Thermal Design Power Intermediate P-State #6 VID Code / VID_VDD Thermal Design Power Min P-State VID Code / VID_VDD Thermal Design Power
Notes 1 1 2 2 2 2
ADA3400AEP5AP 3400+ 04h 00000F48h 00h 0Eh 02h 0Eh 1 MB 800 MHz 2200 MHz 02h 1.500 V 89.0 W 2000 MHz 06h 1.400 V 70.0 W N/A
3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
12
3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
13
3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
14
Parameter/OPN Model Number CPUID 8000_0001h EBX [11:6] (BrandID) CPUID 8000_0001h EAX [31:0] (CPUID) FID/VID Status MaxVID Field FID/VID Status MaxFID Field FID/VID Status StartVID Field FID/VID Status StartFID Field L2 Cache Size Max HyperTransport Frequency Max P-State VID Code VID_VDD Thermal Design Power Intermediate P-State #1 VID Code / VID_VDD Thermal Design Power Intermediate P-State #2 VID Code / VID_VDD Thermal Design Power Intermediate P-State #3 VID Code / VID_VDD Thermal Design Power Intermediate P-State #4 VID Code / VID_VDD Thermal Design Power Intermediate P-State #5 VID Code / VID_VDD Thermal Design Power Intermediate P-State #6 VID Code / VID_VDD Thermal Design Power Min P-State VID Code / VID_VDD Thermal Design Power
Notes 1 1 2 2 2 2
ADA2800AEP4AX 2800+ 04h 00000FC0h 00h 0Ah 02h 0Ah 512 KB 800 MHz 1800 MHz 02h 1.500 V 89.0 W N/A
ADA3000AEP4AX 3000+ 04h 00000FC0h 00h 0Ch 02h 0Ch 512 KB 800 MHz 2000 MHz 02h 1.500 V 89.0 W 1800 MHz 06h 1.400 V 67.0 W N/A
ADA3200AEP4AX 3200+ 04h 00000FC0h 00h 0Eh 02h 0Eh 512 KB 800 MHz 2200 MHz 02h 1.500 V 89.0 W 2000 MHz 06h 1.400 V 69.0 W 1800 MHz 0Ah 1.300 V 50.0 W N/A
3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
15
#VALUE! 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
16
3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
17
3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
18
3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
19
Parameter/OPN Model Number CPUID 8000_0001h EBX [11:6] (BrandID) CPUID 8000_0001h EAX [31:0] (CPUID) FID/VID Status MaxFID Field FID/VID Status StartFID Field L2 Cache Size Max HyperTransport Frequency Max P-State FID/VID Status MaxVID Field FID/VID Status StartVID Field VID Code VID_VDD Thermal Design Power Intermediate P-State #1 VID Code / VID_VDD Thermal Design Power Intermediate P-State #2 VID Code / VID_VDD Thermal Design Power Intermediate P-State #3 VID Code / VID_VDD Thermal Design Power Intermediate P-State #4 VID Code / VID_VDD Thermal Design Power Intermediate P-State #5 VID Code / VID_VDD Thermal Design Power Intermediate P-State #6 VID Code / VID_VDD Thermal Design Power Min P-State VID Code / VID_VDD Thermal Design Power
Notes 1 1 2 2
ADA3500DAA4BN 3500+ 04h 00020F71h 0Eh 0Eh 512 KB 1000 Mhz 2200 MHz 06h 04h 08h 06h 08h 06h 1.350 V 1.400 V 67.0 W 2000 MHz 08h 1.350 V 64.7 W 1800 MHz 1.300 V 0Ah 54.8 W N/A
ADA3700DAA5BN 3700+ 04h 00020F71h 0Eh 0Eh 1 MB 1000 Mhz 2200 MHz 06h 04h 08h 06h 08h 06h 1.400 V 1.350 V 85.3 W 2000 MHz 08h 1.350 V 83.0 W 1800 MHz 0Ah 1.300 V 70.4 W N/A
ADA4000DAA5BN 4000+ 04h 00020F71h 10h 10h 1 MB 1000 Mhz 2400 MHz 06h 04h 08h 06h 06h 08h 1.350 V 1.400 V 85.3 W 2200 MHz 08h 1.350 V 83.0 W 2000 MHz 1.300 V 0Ah 70.6 W 1800 MHz 0Ch 1.250 V 59.6 W N/A
2, 6 2, 6 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
20
2, 6 2, 6 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
N/A
21
Parameter/OPN Model Number CPUID 8000_0001h EBX [11:6] (BrandID) CPUID 8000_0001h EAX [31:0] (CPUID) FID/VID Status MaxFID Field FID/VID Status StartFID Field L2 Cache Size Max HyperTransport Frequency Max P-State FID/VID Status MaxVID Field FID/VID Status StartVID Field VID Code VID_VDD Thermal Design Power Intermediate P-State #1 VID Code / VID_VDD Thermal Design Power Intermediate P-State #2 VID Code / VID_VDD Thermal Design Power Intermediate P-State #3 VID Code / VID_VDD Thermal Design Power Intermediate P-State #4 VID Code / VID_VDD Thermal Design Power Intermediate P-State #5 VID Code / VID_VDD Thermal Design Power Intermediate P-State #6 VID Code / VID_VDD Thermal Design Power Min P-State VID Code / VID_VDD Thermal Design Power
Notes
ADA3800DAA4BP 3800+ 04h 00020FF0h 10h 10h 512 KB 1000 MHz 2400 MHz 06h 04h 08h 06h 08h 06h 1.350 V 1.400 V 85.3 W 2200 MHz 08h 1.350 V 83.0 W 2000 MHz 0Ah 1.300 V 70.6 W 1800 MHz 0Ch 1.250 V 59.6 W N/A
1 1 2 2
2, 6 2, 6 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
22
Parameter/OPN Model Number CPUID 8000_0001h EBX [11:6] (BrandID) CPUID 8000_0001h EAX [31:0] (CPUID) FID/VID Status MaxVID Field FID/VID Status MaxFID Field FID/VID Status StartVID Field FID/VID Status StartFID Field L2 Cache Size Max HyperTransport Frequency Max P-State VID Code VID_VDD Thermal Design Power Intermediate P-State #1 VID Code / VID_VDD Thermal Design Power Intermediate P-State #2 VID Code / VID_VDD Thermal Design Power Intermediate P-State #3 VID Code / VID_VDD Thermal Design Power Intermediate P-State #4 VID Code / VID_VDD Thermal Design Power Intermediate P-State #5 VID Code / VID_VDD Thermal Design Power Intermediate P-State #6 VID Code / VID_VDD Thermal Design Power Min P-State VID Code / VID_VDD Thermal Design Power
Notes 1 1 2 2 2 2
ADA3000DIK4BI 3000+ 04h 00010FF0h 04h 0Ah 06h 0Ah 512 KB 1000 MHz 1800 MHz 06h 1.400 V 67.0 W N/A
ADA3200DIK4BI 3200+ 04h 00010FF0h 04h 0Ch 06h 0Ch 512 KB 1000 MHz 2000 MHz 06h 1.400 V 67.0 W 1800 MHz 08h 1.350 V 56.0 W N/A
ADA3500DIK4BI 3500+ 04h 00010FF0h 04h 0Eh 06h 0Eh 512 KB 1000 MHz 2200 MHz 06h 1.400 V 67.0 W 2000 MHz 08h 1.350 V 56.0 W 1800 MHz 0Ah 1.300 V 46.0 W N/A
3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
23
Parameter/OPN Model Number CPUID 8000_0001h EBX [11:6] (BrandID) CPUID 8000_0001h EAX [31:0] (CPUID) FID/VID Status MaxFID Field FID/VID Status StartFID Field L2 Cache Size Max HyperTransport Frequency Max P-State FID/VID Status MaxVID Field FID/VID Status StartVID Field VID Code VID_VDD Thermal Design Power Intermediate P-State #1 VID Code / VID_VDD Thermal Design Power Intermediate P-State #2 VID Code / VID_VDD Thermal Design Power Intermediate P-State #3 VID Code / VID_VDD Thermal Design Power Intermediate P-State #4 VID Code / VID_VDD Thermal Design Power Intermediate P-State #5 VID Code / VID_VDD Thermal Design Power Intermediate P-State #6 VID Code / VID_VDD Thermal Design Power Min P-State VID Code / VID_VDD Thermal Design Power
Notes
ADA3000DAA4BP 3000+ 04h 00020FF0h 0Ah 0Ah 512 KB 1000 MHz 1800 MHz 06h 04h 08h 06h 08h 06h 1.350 V 1.400 V 67.0 W N/A
ADA3200DAA4BP 3200+ 04h 00020FF0h 0Ch 0Ch 512 KB 1000 MHz 2000 MHz 06h 04h 08h 06h 08h 06h 1.400 V 1.350 V 67.0 W 1800 MHz 1.350 V 08h 64.7 W N/A
ADA3500DAA4BP 3500+ 04h 00020FF0h 0Eh 0Eh 512 KB 1000 MHz 2200 MHz 06h 04h 08h 06h 08h 06h 1.350 V 1.400 V 67.0 W 2000 MHz 08h 1.350 V 64.7 W 1800 MHz 0Ah 1.300 V 54.8 W N/A
1 1 2 2
2, 6 2, 6 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
24
Parameter/OPN Model Number CPUID 8000_0001h EBX [11:6] (BrandID) CPUID 8000_0001h EAX [31:0] (CPUID) FID/VID Status MaxFID Field FID/VID Status StartFID Field L2 Cache Size Max HyperTransport Frequency Max P-State FID/VID Status MaxVID Field FID/VID Status StartVID Field VID Code VID_VDD Thermal Design Power Intermediate P-State #1 VID Code / VID_VDD Thermal Design Power Intermediate P-State #2 VID Code / VID_VDD Thermal Design Power Intermediate P-State #3 VID Code / VID_VDD Thermal Design Power Intermediate P-State #4 VID Code / VID_VDD Thermal Design Power Intermediate P-State #5 VID Code / VID_VDD Thermal Design Power Intermediate P-State #6 VID Code / VID_VDD Thermal Design Power Min P-State VID Code / VID_VDD Thermal Design Power
Notes
ADA3000DAA4BW 3000+ 04h 00020FF2h 0Ah 0Ah 512 KB 1000 MHz 1800 MHz 04h 06h 06h 08h 06h 08h 1.350 V 1.400 V 67.0 W N/A
ADA3200DAA4BW 3200+ 04h 00020FF2h 0Ch 0Ch 512 KB 1000 MHz 2000 MHz 06h 04h 08h 06h 08h 06h 1.350 V 1.400 V 67.0 W 1800 MHz 08h 1.350 V 64.7 W N/A
ADA3500DAA4BW 3500+ 04h 00020FF2h 0Eh 0Eh 512 KB 1000 MHz 2200 MHz 06h 04h 08h 06h 08h 06h 1.400 V 1.350 V 67.0 W 2000 MHz 08h 1.350 V 64.7 W 1800 MHz 0Ah 1.300 V 54.8 W N/A
1 1 2 2
2, 6 2, 6 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
25
2, 6 2, 6 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
26
Parameter/OPN Model Number CPUID 8000_0001h EBX [11:6] (BrandID) CPUID 8000_0001h EAX [31:0] (CPUID) FID/VID Status MaxFID Field FID/VID Status StartFID Field L2 Cache Size Max HyperTransport Frequency Max P-State FID/VID Status MaxVID Field FID/VID Status StartVID Field VID Code VID_VDD Thermal Design Power Intermediate P-State #1 VID Code / VID_VDD Thermal Design Power Intermediate P-State #2 VID Code / VID_VDD Thermal Design Power Intermediate P-State #3 VID Code / VID_VDD Thermal Design Power Intermediate P-State #4 VID Code / VID_VDD Thermal Design Power Intermediate P-State #5 VID Code / VID_VDD Thermal Design Power Intermediate P-State #6 VID Code / VID_VDD Thermal Design Power Min P-State VID Code / VID_VDD Thermal Design Power
Notes
ADA3800DAA4BW 3800+ 04h 00020FF2h 10h 10h 512 KB 1000 MHz 2400 MHz 06h 04h 08h 06h 08h 06h 1.350 V 1.400 V 85.3 W 2200 MHz 08h 1.350 V 83.0 W 2000 MHz 0Ah 1.300 V 70.6 W 1800 MHz 0Ch 1.250 V 59.6 W N/A
1 1 2 2
2, 6 2, 6 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
27
1 1 2 2
2, 6 2, 6 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
28
Notes: 1 CPUID extended function 8000_0001h fields are used by BIOS in uniquely associating a given processor to the Pstates that are valid for that processor. Refer to the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094. 2 FIDVID Status Register, M SR C001_0042h. 3 The VID_VDD voltage is the VID[4:0] requested VDD supply level. Refer to the appropriate functional data sheet for details. 4 Thermal Design Power (TDP) is measured under the conditions of Tcase M ax, IDD M ax, and VDD=VID_VDD, and include all power dissipated on-die from VDD, VDDIO, VLDT, VTT, and VDDA. 5 Implementation of this P-state is optional in BIOS. 6 StartVID and M axVID are programmed during device manufacturing with part-specific values for Rev E and later processors, and can have one or more valid options. All valid options for StartVID, M axVID, and VID_VDD will be specified for the corresponding OPN. For information on the relationship of StartVID and M axVID to VID_VDD refer to the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094. Contact your FAE for more info on TDP specifications.
29
3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
30
Parameter/OPN Tcase Max Tcontrol Max Tambient Thermal Resistance (case-amb) Max P-S tate VID_VDD IDD Max Thermal Design Power Intermediate P-State #1 VID_VDD IDD Max Thermal Design Power Intermediate P-State #2 VID_VDD IDD Max Thermal Design Power Intermediate P-State #3 VID_VDD IDD Max Thermal Design Power Intermediate P-State #4 VID_VDD IDD Max Thermal Design Power Intermediate P-State #5 VID_VDD IDD Max Thermal Design Power Intermediate P-State #6 VID_VDD IDD Max Thermal Design Power Min P-State VID_VDD IDD Max Thermal Design Power Halt/S top Grant IDDC1 Max @ Max P-State IDDC1 Max @ Min P-State I/O Power S3 I/O Power
Notes 1 2
3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
ADA3400AEP5AP 70C 70C 42C 0.31C/W 2200 MHz 1.500 V 57.8 A 89.0 W 2000 MHz 1.400 V 48.4 A 70.0 W N/A
N/A
N/A
N/A
N/A
31
3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
32
3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
N/A
N/A
33
Parameter/OPN Tcase Max Tcontrol Max Tambient Thermal Resistance (case-amb) Max P-S tate VID_VDD IDD Max Thermal Design Power Intermediate P-State #1 VID_VDD IDD Max Thermal Design Power Intermediate P-State #2 VID_VDD IDD Max Thermal Design Power Intermediate P-State #3 VID_VDD IDD Max Thermal Design Power Intermediate P-State #4 VID_VDD IDD Max Thermal Design Power Intermediate P-State #5 VID_VDD IDD Max Thermal Design Power Intermediate P-State #6 VID_VDD IDD Max Thermal Design Power Min P-State VID_VDD IDD Max Thermal Design Power Halt/S top Grant IDDC1 Max @ Max P-State IDDC1 Max @ Min P-State I/O Power S3 I/O Power
Notes 1 2
3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
ADA2800AEP4AX 70C 70C 42C 0.31C/W 1800 MHz 1.500 V 57.8 A 89.0 W N/A
N/A
ADA3000AEP4AX 70C 70C 42C 0.31C/W 2000 MHz 1.500 V 57.8 A 89.0 W 1800 MHz 1.400 V 46.0 A 67.0 W N/A
N/A
N/A
ADA3200AEP4AX 70C 70C 42C 0.31C/W 2200 MHz 1.500 V 57.8 A 89.0 W 2000 MHz 1.400 V 48.0 A 69.0 W 1800 MHz 1.300 V 37.0 A 50.0 W N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
34
3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
N/A
N/A
35
3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
N/A
N/A
N/A
36
3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
N/A
N/A
N/A
37
3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
N/A
N/A
N/A
N/A
38
14 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
39
14 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
N/A
N/A
N/A
N/A
N/A
40
14 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
N/A
N/A
41
Parameter/OPN Tcase Max Tcontrol Max Tambient Thermal Resistance (case-amb) Max P-S tate VID_VDD IDD Max Thermal Design Power Intermediate P-State #1 VID_VDD IDD Max Thermal Design Power Intermediate P-State #2 VID_VDD IDD Max Thermal Design Power Intermediate P-State #3 VID_VDD IDD Max Thermal Design Power Intermediate P-State #4 VID_VDD IDD Max Thermal Design Power Intermediate P-State #5 VID_VDD IDD Max Thermal Design Power Intermediate P-State #6 VID_VDD IDD Max Thermal Design Power Min P-State VID_VDD IDD Max Thermal Design Power Halt/S top Grant IDDC1 Max @ Max P-State IDDC1 Max @ Min P-State I/O Power S3 I/O Power
Notes 1 2
3 9 4, 9 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
ADA3000DIK4BI 65C 70C 42C 0.34C/W 1800 MHz 1.400 V 45.8 A 67.0 W N/A
N/A
ADA3200DIK4BI 65C 70C 42C 0.34C/W 2000 MHz 1.400 V 45.8 A 67.0 W 1800 MHz 1.350 V 39.3 A 56.0 W N/A
N/A
N/A
ADA3500DIK4BI 65C 70C 42C 0.34C/W 2200 MHz 1.400 V 45.8 A 67.0 W 2000 MHz 1.350 V 39.3 A 56.0 W 1800 MHz 1.300 V 33.2 A 46.0 W N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
42
14 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
43
14 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Thermal Design Power 4 Min P-S tate VID_VDD 3 IDD M ax Thermal Design Power 4 Halt/S top Grant IDDC1 M ax @ M ax P-State 5 IDDC1 M ax @ M in P-State 6 I/O Power 8, 12 7 S3 I/O Power 7, 9, 12 The notes for this table appear on page 48.
44
14 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3
N/A
N/A
N/A
N/A
Thermal Design Power 4 Min P-S tate VID_VDD 3 IDD M ax Thermal Design Power 4 Halt/S top Grant IDDC1 M ax @ M ax P-State 5 IDDC1 M ax @ M in P-State 6 I/O Power 8, 12 7 S3 I/O Power 7, 9, 12 The notes for this table appear on page 48.
45
14 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3
N/A
N/A
Thermal Design Power 4 Min P-S tate VID_VDD 3 IDD M ax Thermal Design Power 4 Halt/S top Grant IDDC1 M ax @ M ax P-State 5 IDDC1 M ax @ M in P-State 6 I/O Power 8, 12 7 S3 I/O Power 7, 9, 12 The notes for this table appear on page 48.
46
14 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
N/A
N/A
N/A
N/A
47
Notes: 1. Tcase max is the maximum case temperature specification which is a physical value in degrees Celsius. This value is programmed into Rev D and later processors. Refer to the appropriate functional data sheet, and the THERM TRIP Status Register in the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094. 2. Tcontrol max (maximum control temperature) is a non physical temperature on an arbitrary scale that can be used for system thermal management policies. Tcontrol max represents the value at which the processor has reached Tcase max when measuring the thermal diode with a dual sourcing current temperature sensor. Refer to the appropriate functional data sheet, and the THERM TRIP Status Register in the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094. 3. The VID_VDD voltage is the VID[4:0] requested VDD supply level. Refer to the appropriate functional data sheet for details. 4. Thermal Design Power (TDP) is measured under the conditions of Tcase M ax, IDD M ax, and VDD=VID_VDD, and include all power dissipated on-die from VDD, VDDIO, VLDT, VTT, and VDDA. 5. Assumes Tcase max, max P-state VID_VDD, clock divider set to 32. 6. Assumes 50C, min P-state VID_VDD, clock divider set to 32. 7. Assumes 35C, VDD, VDDA, and VLDT supplies are off, VDDIO and VTT are powered, memory in selfrefresh mode and DDR SDRAM interface tri-stated except CKE pins. Refer to the appropriate functional data sheet for complete VDDIO and VTT power supply specifications. 8. Thermal Design Power dissipated by the processor VDDIO, VTT, VLDT, and VDDA power planes only. 9. Thermal Design Power dissipated by the processor VDDIO and VTT power planes only. 10. Refer to the AM D Athlon 64 Processor Desktop Power Roadmap, order #26882, for IDD M ax and Thermal Design Power requirements for future processor revisions. 11. Implementation of this P-state is optional in BIOS. 12. Assumes VDDIO = 2.6 V and VTT = VDDIO / 2. Refer to the appropriate functional data sheet for complete VDDIO and VTT power supply specifications. 13. Tcase max is programmed during device manufacturing with part-specific values for Rev E and later processors, and can be any valid Tcase max value in the range specified for the corresponding OPN. 14 Thermal Design Power (TDP) and IDD max for Rev E and later processors are the limits at the highest Tcase max in the specified range for the corresponding OPN. Products will conform to the TDP and IDD M ax limits at all valid voltages. The relationship of Tcase max and Thermal Profile to TDP for a specific device is defined in Table 8.
48
The following sections contain thermal/power and related BIOS specifications for AMD Athlon 64 FX processors. Each column in the BIOS and thermal/power tables represents a specific Ordering Part Number (OPN). Section 2.1 provides an example of the OPN structure for this processor family. For all other electrical specifications for the processor, refer to the AMD Athlon 64 FX Product Data Sheet, order #30431. For power management BIOS requirements, refer to the BIOS and Kernel Developers Guide for AMD Athlon 64 Processors and AMD Opteron Processors, order #26094.
Part Definition: AK= Rev C0 (see Table 11) L2 Cache Size: 5= 1 Megabyte (see Table 12) Case Temperature: P= 70oC (see Table 13) Operating Voltage: E= 1.50 V (see Table 14) Package: C= 940 pin lidded CPGA (see Table 15) Model Number: FX51: 2200 MHz (see Table 16) Brand: AMD Athlon 64 Desktop
Figure 2.
Revision
Rev C0 Rev CG Rev CG Rev E4
49
Cache Size
1 MB
Temperature
70oC 63oC Variable
Operating Voltage
1.50 V Variable
Package
940 Pin Lidded CPGA 939 Pin Lidded OPGA
Frequency
2200 MHz 2400 MHz 2600 MHz 2800 MHz
50
Tcase Max 49C 51C 53C 55C 57C 59C 61C 63C 65C 67C 69C 71C
Power (Thermal Profile G) 40.9 W 50.0 W 59.1 W 68.2 W 77.3 W 86.4 W 95.5 W 104.0 W N/A N/A N/A N/A
51
3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
52
Parameter/OPN M odel Number CPUID 8000_0001h EBX [11:6] (BrandID) CPUID 8000_0001h EAX [31:0] (CPUID) FID/VID Status MaxVID Field FID/VID Status MaxFID Field FID/VID Status StartVID Field FID/VID Status StartFID Field L2 Cache Size Max P-S tate VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #1 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #2 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #3 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #4 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #5 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #6 VID Code / VID_VDD Thermal Design Power Min P-State VID Code / VID_VDD Thermal Design Power
Notes 1 1 2 2 2 2
ADAFX53DEP5AS FX53 24h 00000F7Ah 00h 2Ah 02h 10h 1 MB 2400 M Hz 02h 1.500 V 89.0 W N/A
ADAFX55DEI5AS FX55 24h 00000F7Ah 00h 2Ah 02h 12h 1 MB 2600 MHz 02h 1.500 V 104.0 W N/A
3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
53
2, 6 2, 6 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
54
Notes: 1 CPUID extended function 8000_0001h fields are used by BIOS in uniquely associating a given p rocessor to the Pstates that are valid for that p rocessor. Refer to the BIOS and Kernel Develop ers Guide for AM D Athlon 64 and AM D Op teron Processors, order# 26094. 2 FIDVID Status Register, M SR C001_0042h. 3 The VID_VDD voltage is the VID[4:0] requested VDD sup p ly level. Refer to the ap p rop riate functional data sheet for details. 4 Thermal Design Power (TDP) is measured under the conditions of Tcase M ax, IDD M ax, and VDD=VID_VDD, and include all p ower dissip ated on-die from VDD, VDDIO, VLDT, VTT, and VDDA. 5 Imp lementation of this P-state is op tional in BIOS. 6 StartVID and M axVID are p rogrammed during device manufacturing with p art-sp ecific values for Rev E and later p rocessors, and can have one or more valid op tions. All valid op tions for StartVID, M axVID, and VID_VDD will be sp ecified for the corresp onding OPN. For information on the relationship of StartVID and M axVID to VID_VDD refer to the BIOS and Kernel Develop ers Guide for AM D Athlon 64 and AM D Op teron Processors, order# 26094. Contact y our FAE for more info on TDP sp ecifications. 7 Thermal Design Power (TDP) sp ecifications for dual core p rocessors assume equivalent P-states (Voltage and frequency ) and equivalent Tcase conditions for both cores. Refer to the BIOS and Kernel Develop ers Guide for AM D Athlon 64 and AM D Op teron Processors, order# 26094, for details on P-state op eration for dual core p rocessors.
55
3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
56
Parameter/OPN Tcase Max Tcontrol Max Tambient Thermal Resistance (case-amb) Max P-S tate VID_VDD IDD Max Thermal Design Power Intermediate P-State #1 VID_VDD IDD Max Thermal Design Power Intermediate P-State #2 VID_VDD IDD Max Thermal Design Power Intermediate P-State #3 VID_VDD IDD Max Thermal Design Power Intermediate P-State #4 VID_VDD IDD Max Thermal Design Power Intermediate P-State #5 VID_VDD IDD Max Thermal Design Power Intermediate P-State #6 VID_VDD IDD Max Thermal Design Power Min P-State VID_VDD IDD Max Thermal Design Power Halt/S top Grant IDDC1 Max @ Max P-State IDDC1 Max @ Min P-State I/O Power S3 I/O Power
Notes 1 2
3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
ADAFX53DEP5AS 70C 70C 42C 0.31C/W 2400 MHz 1.500 V 57.4 A 89.0 W N/A
ADAFX55DEI5AS 63C 63C 40C 0.22C/W 2600 MHz 1.500 V 67.4 A 104.0 W N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
57
14 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
58
Notes: 1. Tcase max is the maximum case temperature specification which is a physical value in degrees Celsius. This value is programmed into Rev D and later processors. Refer to the appropriate functional data sheet, and the THERM TRIP Status Register in the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094. 2. Tcontrol max (maximum control temperature) is a non physical temperature on an arbitrary scale that can be used for system thermal management policies. Tcontrol max represents the value at which the processor has reached Tcase max when measuring the thermal diode with a dual sourcing current temperature sensor. Refer to the appropriate functional data sheet, and the THERM TRIP Status Register in the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094. 3. The VID_VDD voltage is the VID[4:0] requested VDD supply level. Refer to the appropriate functional data sheet for details. 4. Thermal Design Power (TDP) is measured under the conditions of Tcase M ax, IDD M ax, and VDD=VID_VDD, and include all power dissipated on-die from VDD, VDDIO, VLDT, VTT, and VDDA. 5. Assumes Tcase max, max P-state VID_VDD, clock divider set to 32. 6. Assumes 50C, min P-state VID_VDD, clock divider set to 32. 7. Assumes 35C, VDD, VDDA, and VLDT supplies are off, VDDIO and VTT are powered, memory in selfrefresh mode and DDR SDRAM interface tri-stated except CKE pins. Refer to the appropriate functional data sheet for complete VDDIO and VTT power supply specifications. 8. Thermal Design Power dissipated by the processor VDDIO, VTT, VLDT, and VDDA power planes only. 9. Thermal Design Power dissipated by the processor VDDIO and VTT power planes only. 10. Refer to the AM D Athlon 64 Processor Desktop Power Roadmap, order #26882, for IDD M ax and Thermal Design Power requirements for future processor revisions. 11. Implementation of this P-state is optional in BIOS. 12. Assumes VDDIO = 2.6 V and VTT = VDDIO / 2. Refer to the appropriate functional data sheet for complete VDDIO and VTT power supply specifications. 13. Tcase max is programmed during device manufacturing with part-specific values for Rev E and later processors, and can be any valid Tcase max value in the range specified for the corresponding OPN. 14 Thermal Design Power (TDP) and IDD max for Rev E and later processors are the limits at the highest Tcase max in the specified range for the corresponding OPN. Products will conform to the TDP and IDD M ax limits at all valid voltages. The relationship of Tcase max and Thermal Profile to TDP for a specific device is defined in Table 17.
59
The following sections contain thermal/power and related BIOS specifications for AMD Sempron processors. Each column in the BIOS and thermal/power tables represents a specific Ordering Part Number (OPN). Section 3.1 provides an example of the OPN structure for this processor family. For all other electrical specifications for the processor, refer to the AMD Sempron Product Data Sheet, order #31804. For power management BIOS requirements, refer to the BIOS and Kernel Developers Guide for AMD Athlon 64 Processors and AMD Opteron Processors, order #26094.
Part Definition: AX= Rev CG (see Table 20) L2 Cache Size: 3= 256 KB (see Table 21) Case Temperature: P= 70oC (see Table 22) Operating Voltage: I= 1.40 V (see Table 23) Package: A= 754 pin lidded OPGA (see Table 24) Model Number: 3100: 1800 MHz (see Table 25) Brand: AMD Sempron Desktop
Figure 3.
Revision
Rev CG Rev D0 Rev E6
Package Drawing
Lidded Lidded Lidded
60
Cache Size
256 KB 128 KB
Temperature
70oC 69oC
Operating Voltage
1.40 V
Package
754 Pin Lidded OPGA
Model Number
2600+ 2800+ 3000+ 3100+ 3300+ 2500+ 3400+
754 Pin Lidded OPGA 128 KB 754 Pin Lidded OPGA 256 KB 754 Pin Lidded OPGA 128 KB 754 Pin Lidded OPGA 256 KB 754 Pin Lidded OPGA 128 KB 754 Pin Lidded OPGA 256 KB 754 Pin Lidded OPGA 256 KB
61
3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
N/A
62
Parameter/OPN M odel Number CPUID 8000_0001h EBX [11:6] (BrandID) CPUID 8000_0001h EAX [31:0] (CPUID) FID/VID Status MaxVID Field FID/VID Status MaxFID Field FID/VID Status StartVID Field FID/VID Status StartFID Field L2 Cache Size Max P-S tate VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #1 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #2 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #3 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #4 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #5 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #6 VID Code / VID_VDD Thermal Design Power Min P-State VID Code / VID_VDD Thermal Design Power
Notes 1 1 2 2 2 2
S DA2600AIO2BA 2600+ 22h 00010FC0h 04h 08h 06h 08h 128 KB 1600 M Hz 06h 1.400 V 59.0 W N/A
S DA2800AIO3BA 2800+ 22h 00010FC0h 04h 08h 06h 08h 256 KB 1600 MHz 06h 1.400 V 59.0 W N/A
S DA3000AIO2BA 3000+ 22h 00010FC0h 04h 0Ah 06h 0Ah 128 KB 1800 M Hz 06h 1.400 V 59.0 W N/A
3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
63
Parameter/OPN M odel Number CPUID 8000_0001h EBX [11:6] (BrandID) CPUID 8000_0001h EAX [31:0] (CPUID) FID/VID Status M axVID Field FID/VID Status M axFID Field FID/VID Status StartVID Field FID/VID Status StartFID Field L2 Cache Size Max P-S tate VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #1 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #2 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #3 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #4 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #5 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #6 VID Code / VID_VDD Thermal Design Power Min P-S tate VID Code / VID_VDD Thermal Design Power
Notes 1 1 2 2 2 2
S DA3100AIO3BA 3100+ 22h 00010FC0h 04h 0Ah 06h 0Ah 256 KB 1800 M Hz 06h 1.400 V 59.0 W N/A
S DA3300AIO2BA 3300+ 22h 00010FC0h 04h 0Ch 06h 0Ch 128 KB 2000 M Hz 06h 1.400 V 59.0 W 1800 M Hz 08h 1.350 V 48.8 W N/A
3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
64
Parameter/OPN M odel Number CPUID 8000_0001h EBX [11:6] (BrandID) CPUID 8000_0001h EAX [31:0] (CPUID) FID/VID Status M axVID Field FID/VID Status M axFID Field FID/VID Status StartVID Field FID/VID Status StartFID Field L2 Cache Size Max P-S tate VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #1 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #2 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #3 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #4 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #5 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #6 VID Code / VID_VDD Thermal Design Power Min P-S tate VID Code / VID_VDD Thermal Design Power
Notes 1 1 2 2 2 2
S DA2500AIO3BX 2500+ 26h 00020FC2h 04h 06h 06h 06h 256 KB 1400 M Hz 06h 1.400 V 59.0 W N/A
3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
N/A
N/A
65
Parameter/OPN M odel Number CPUID 8000_0001h EBX [11:6] (BrandID) CPUID 8000_0001h EAX [31:0] (CPUID) FID/VID Status M axVID Field FID/VID Status M axFID Field FID/VID Status StartVID Field FID/VID Status StartFID Field L2 Cache Size Max P-S tate VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #1 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #2 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #3 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #4 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #5 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #6 VID Code / VID_VDD Thermal Design Power Min P-S tate VID Code / VID_VDD Thermal Design Power
Notes 1 1 2 2 2 2
S DA2600AIO2BX 2600+ 26h 00020FC2h 04h 08h 06h 08h 128 KB 1600 M Hz 06h 1.400 V 59.0 W N/A
S DA2800AIO3BX 2800+ 26h 00020FC2h 04h 08h 06h 08h 256 KB 1600 M Hz 06h 1.400 V 59.0 W N/A
S DA3000AIO2BX 3000+ 26h 00020FC2h 04h 0Ah 06h 0Ah 128 KB 1800 M Hz 06h 1.400 V 59.0 W N/A
3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
66
Parameter/OPN M odel Number CPUID 8000_0001h EBX [11:6] (BrandID) CPUID 8000_0001h EAX [31:0] (CPUID) FID/VID Status M axVID Field FID/VID Status M axFID Field FID/VID Status StartVID Field FID/VID Status StartFID Field L2 Cache Size Max P-S tate VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #1 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #2 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #3 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #4 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #5 VID Code / VID_VDD Thermal Design Power Intermediate P-S tate #6 VID Code / VID_VDD Thermal Design Power Min P-S tate VID Code / VID_VDD Thermal Design Power
Notes 1 1 2 2 2 2
S DA3100AIO3BX 3100+ 26h 00020FC2h 04h 0Ah 06h 0Ah 256 KB 1800 M Hz 06h 1.400 V 59.0 W N/A
S DA3300AIO2BX 3300+ 26h 00020FC2h 04h 0Ch 06h 0Ch 128 KB 2000 M Hz 06h 1.400 V 59.0 W 1800 M Hz 08h 1.350 V 49.6 W N/A
S DA3400AIO3BX 3400+ 26h 00020FC2h 04h 0Ch 06h 0Ch 256 KB 2000 M Hz 06h 1.400 V 59.0 W 1800 M Hz 08h 1.350 V 49.6 W N/A
3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 5 3 4 3 4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
67
3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
N/A
N/A
N/A
N/A
N/A
68
Parameter/OPN Tcase M ax Tcontrol M ax Tambient Thermal Resistance (case-amb) Max P-S tate VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #1 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #2 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #3 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #4 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #5 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #6 VID_VDD IDD M ax Thermal Design Power Min P-S tate VID_VDD IDD M ax Thermal Design Power Halt/S top Grant IDDC1 M ax @ M ax P-State IDDC1 M ax @ M in P-State I/O Power S3 I/O Power
Notes 1 2
3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4
S DA2600AIO2BA 69C 70C 42C 0.45C/W 1600 M Hz 1.400 V 40.6 A 59.0 W N/A
S DA2800AIO3BA 69C 70C 42C 0.45C/W 1600 M Hz 1.400 V 40.6 A 59.0 W N/A
S DA3000AIO2BA 69C 70C 42C 0.45C/W 1800 M Hz 1.400 V 40.6 A 59.0 W N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
69
Parameter/OPN Tcase M ax Tcontrol M ax Tambient Thermal Resistance (case-amb) Max P-S tate VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #1 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #2 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #3 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #4 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #5 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #6 VID_VDD IDD M ax Thermal Design Power Min P-S tate VID_VDD IDD M ax Thermal Design Power Halt/S top Grant IDDC1 M ax @ M ax P-State IDDC1 M ax @ M in P-State I/O Power S3 I/O Power
Notes 1 2
3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
S DA3100AIO3BA 69C 70C 42C 0.45C/W 1800 M Hz 1.400 V 40.6 A 59.0 W N/A
N/A
S DA3300AIO2BA 69C 70C 42C 0.45C/W 2000 M Hz 1.400 V 40.6 A 59.0 W 1800 M Hz 1.350 V 34.5 A 48.8 W N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
70
Parameter/OPN Tcase M ax Tcontrol M ax Tambient Thermal Resistance (case-amb) Max P-S tate VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #1 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #2 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #3 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #4 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #5 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #6 VID_VDD IDD M ax Thermal Design Power Min P-S tate VID_VDD IDD M ax Thermal Design Power Halt/S top Grant IDDC1 M ax @ M ax P-State IDDC1 M ax @ M in P-State I/O Power S3 I/O Power
Notes 1 2
3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4
S DA2500AIO3BX 69C 70C 42C 0.45C/W 1400 M Hz 1.400 V 40.6 A 59.0 W N/A
N/A
N/A
N/A
N/A
N/A
71
Parameter/OPN Tcase M ax Tcontrol M ax Tambient Thermal Resistance (case-amb) Max P-S tate VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #1 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #2 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #3 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #4 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #5 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #6 VID_VDD IDD M ax Thermal Design Power Min P-S tate VID_VDD IDD M ax Thermal Design Power Halt/S top Grant IDDC1 M ax @ M ax P-State IDDC1 M ax @ M in P-State I/O Power S3 I/O Power
Notes 1 2
3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4
S DA2600AIO2BX 69C 70C 42C 0.45C/W 1600 M Hz 1.400 V 40.6 A 59.0 W N/A
S DA2800AIO3BX 69C 70C 42C 0.45C/W 1600 M Hz 1.400 V 40.6 A 59.0 W N/A
S DA3000AIO2BX 69C 70C 42C 0.45C/W 1800 M Hz 1.400 V 40.6 A 59.0 W N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
72
Parameter/OPN Tcase M ax Tcontrol M ax Tambient Thermal Resistance (case-amb) Max P-S tate VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #1 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #2 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #3 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #4 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #5 VID_VDD IDD M ax Thermal Design Power Intermediate P-S tate #6 VID_VDD IDD M ax Thermal Design Power Min P-S tate VID_VDD IDD M ax Thermal Design Power Halt/S top Grant IDDC1 M ax @ M ax P-State IDDC1 M ax @ M in P-State I/O Power S3 I/O Power
Notes 1 2
3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 11 3 4 3 4 5 6 8, 12 7 7, 9, 12
S DA3100AIO3BX 69C 70C 42C 0.45C/W 1800 M Hz 1.400 V 40.6 A 59.0 W N/A
N/A
S DA3300AIO2BX 69C 70C 42C 0.45C/W 2000 M Hz 1.400 V 40.6 A 59.0 W 1800 M Hz 1.350 V 35.1 A 49.6 W N/A
S DA3400AIO3BX 69C 70C 42C 0.45C/W 2000 M Hz 1.400 V 40.6 A 59.0 W 1800 M Hz 1.350 V 35.1 A 49.6 W N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
73
Notes: 1. Tcase max is the maximum case temperature specification which is a physical value in degrees Celsius. This value is programmed into Rev D and later processors. Refer to the appropriate functional data sheet, and the THERM TRIP Status Register in the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094. 2. Tcontrol max (maximum control temperature) is a non physical temperature on an arbitrary scale that can be used for system thermal management policies. Tcontrol max represents the value at which the processor has reached Tcase max when measuring the thermal diode with a dual sourcing current temperature sensor. Refer to the appropriate functional data sheet, and the THERM TRIP Status Register in the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094. 3. The VID_VDD voltage is the VID[4:0] requested VDD supply level. Refer to the appropriate functional data sheet for details. 4. Thermal Design Power (TDP) is measured under the conditions of Tcase M ax, IDD M ax, and VDD=VID_VDD, and include all power dissipated on-die from VDD, VDDIO, VLDT, VTT, and VDDA. 5. Assumes Tcase max, max P-state VID_VDD, clock divider set to 32. 6. Assumes 50C, min P-state VID_VDD, clock divider set to 32. 7. Assumes 35C, VDD, VDDA, and VLDT supplies are off, VDDIO and VTT are powered, memory in selfrefresh mode and DDR SDRAM interface tri-stated except CKE pins. Refer to the appropriate functional data sheet for complete VDDIO and VTT power supply specifications. 8. Thermal Design Power dissipated by the processor VDDIO, VTT, VLDT, and VDDA power planes only. 9. Thermal Design Power dissipated by the processor VDDIO and VTT power planes only. 10. Refer to the AM D Athlon 64 Processor Desktop Power Roadmap, order #26882, for IDD M ax and Thermal Design Power requirements for future processor revisions. 11. Implementation of this P-state is optional in BIOS. 12. Assumes VDDIO = 2.6 V and VTT = VDDIO / 2. Refer to the appropriate functional data sheet for complete VDDIO and VTT power supply specifications.
74
Figure 4. AMD Turion 64 Mobile Technology Ordering Part Number Example Table 28: AMD Turion 64 Mobile Technology Part Definition Options
Part Definition
LD
VID Voltage
Revision
Package Drawing
B4
Note: Refer to the AMD Functional Data Sheet, 754 Pin Package, order #31410, for package drawings. Refer to the BIOS and Kernel Developers Guide for AMD Athlon 64 Processors and AMD Opteron Processors, order #26094, for information on translating VID Codes to Standard or Low Power Mobile Voltages.
75
Cache Size
1 MB 512 KB
Temperature
95oC
Operating Voltage
1.20 V
Package
754 Pin Lidless OPGA
Power Limit
25 W
76
4, 5 6 7 4, 5 6 7 4, 5 6 7 4, 5 6 7 4, 5 6 7 4, 5 6 7 4, 5 6 4, 5 6
N/A
N/A
N/A
N/A
77
Notes TMS MT34BQX5LD M T34 1 1 2 2 2 2 3, 4, 5 0Bh 00020F42h 08h 0Ah 16h 00h 0.850 V 1 MB 1800 M Hz 0Ah 1.200 V 24.0 W 1600 M Hz 0Ch 1.150 V 19.9 W N/A 18h
4, 5 6 7 4, 5 6 7 4, 5 6 7 4, 5 6 7 4, 5 6 7 4, 5 6 7 4, 5 6 4, 5 6
N/A
N/A
N/A
N/A
N/A
N/A
N/A
78
Notes: 1. CPUID extended function 8000_0001h fields are used by BIOS in uniquely associating a given processor to the Pstates that are valid for that processor. Refer to the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094. 2. FIDVID Status Register, M SR C001_0042h. 3. BIOS programs the AltVID setting into Function 3: Offset D8h. Not all systems are AltVID capable. Refer to the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094 for further details. 4. The VID_VDD voltage for Low Power M obile parts corresponds to 0 load (0 Amp IDD) conditions for the VID[4:0] requested VDD supply level. Refer to the AM D Functional Data Sheet, 754 Pin Package, order #31410, for details. 5. Refer to the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order #26094, for information on translating VID Codes to Standard or Low Power M obile Voltages. 6. Thermal Design Power (TDP) for Low Power M obile parts is measured under the conditions of Tdie M ax, IDD M ax, and VDD=VDD_dc Typ, and include all power dissipated on-die from VDD, VDDIO, VLDT, VTT, and VDDA. Contact your Field Application Engineer for more information on TDP specifications. 7. Implementation of this P-state is optional in BIOS.
79
80
N/A
N/A
N/A
N/A
800 M Hz 0.900 V 0.889 V 6.19 A 7.9 W 6.10 A 1.46 A 2.2 W 0.83 A 360 mW 0.850 V 0.64 A 360 mW 250 mW
81
N/A
N/A
N/A
N/A
N/A
N/A
N/A
800 M Hz 0.900 V 0.888 V 6.42 A 7.9 W 6.10 A 1.46 A 2.2 W 0.83 A 360 mW 0.850 V 0.64 A 360 mW 250 mW
800 M Hz 0.900 V 0.888 V 6.42 A 7.9 W 6.10 A 1.46 A 2.2 W 0.83 A 360 mW 0.850 V 0.64 A 360 mW 250 mW
82
Notes: 1. The VID_VDD voltage for Low Power M obile parts corresponds to 0 load (0 Amp IDD) conditions for the VID[4:0] requested VDD supply level. Refer to the AM D Functional Data Sheet, 754 Pin Package, order #31410, for details. 2. The VDD_dc Typical Voltage is calculated using the following formula: VDD_dc Typ = VID_VDD 1.83 mV/A * IDD M ax. Refer to the AM D Functional Data Sheet, 754 Pin Package, order# 31410, for complete VDD specifications. 3. Thermal Design Power (TDP) for Low Power M obile parts is measured under the conditions of Tdie M ax, IDD M ax, and VDD=VDD_dc Typ, and include all power dissipated on-die from VDD, VDDIO, VLDT, VTT, and VDDA. Contact your Field Application Engineer for more information on TDP specifications. 4. Assumes Tdie max, max P-state VDD_dc Typ +25 mV, clock divider set to 512. 5. Assumes 50C, min P-state VID_VDD, clock divider set to 512. 6. Assumes 35C, min P-state VID_VDD, clock divider set to 512, HyperTransport links disconnected, memory in self-refresh mode, DDR SDRAM interface tri-stated except clocks and CKE pins. 7. Assumes 35C, AltVID, clock divider set to 512, HyperTransport links disconnected, memory in self-refresh mode, DDR SDRAM interface tri-stated except CKE pins. Not all systems are AltVID capable. Refer to the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094 for further details. 8. BIOS programs the AltVID setting into Function 3: Offset D8h. Not all systems are AltVID capable. Refer to the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094 for further details. 9. Assumes 35C, VDD, VDDA, and VLDT supplies are off, VDDIO and VTT are powered, memory in self-refresh mode and DDR SDRAM interface tri-stated except CKE pins. 10. Thermal Design Power dissipated by the processor VDDIO, VTT, VLDT, and VDDA power planes only. 11. Thermal Design Power dissipated by the processor VDDIO and VTT power planes only. 12. Implementation of this P-state is optional in BIOS. 13. Assumes VDDIO = 2.5 V and VTT = VDDIO / 2. Refer to the AM D Functional Data Sheet, 754 Pin Package, order# 31410 for complete VDDIO and VTT power supply specifications.
83
The following sections contain thermal/power and related BIOS specifications for AMD Athlon 64 X2 Dual Core processors. Each column in the BIOS and thermal/power tables represents a specific Ordering Part Number (OPN). Section 5.1 provides an example of the OPN structure for this processor family. For power management BIOS requirements, refer to the BIOS and Kernel Developers Guide for AMD Athlon 64 Processors and AMD Opteron Processors, order #26094.
Figure 5. AMD Athlon 64 X2 Dual Core Processor Ordering Part Number Example Table 37: AMD Athlon 64 X2 Dual Core Processor Part Definition Options
Part Definition
BV CD
Revision
Rev E4 Rev E6
Package Drawing
Lidded Lidded
Note: Refer to AMD Functional Data Sheet, 939 Pin Package, order #31411 for package drawings.
Table 38: AMD Athlon 64 X2 Dual Core Processor L2 Cache Size Options
OPN Character
5 6
Cache Size
1 MB 2 MB
84
Temperature
Variable
Operating Voltage
Variable
Package
939 Pin Lidded OPGA
Table 42: AMD Athlon 64 X2 Dual Core Processor Model Number Options
Package Cache Size Frequency
2200 MHz 2400 MHz 2000 MHz 2200 MHz 2400 MHz
Model Number
4400+ 4800+ 3800+ 4200+ 4600+
939 Pin Lidded OPGA 2 MB 939 Pin Lidded OPGA 2 MB 939 Pin Lidded OPGA 1 MB 939 Pin Lidded OPGA 1 MB 939 Pin Lidded OPGA 1 MB
Power Limit
Standard
85
Tcase Max 49C 51C 53C 55C 57C 59C 61C 63C 65C 67C 69C 71C
Power Power (Thermal Profile O) (Thermal Profile P) 35.0 W 21.9 W 45.0 W 28.1 W 55.0 W 34.4 W 65.0 W 40.6 W 75.0 W 46.9 W 85.0 W 53.1 W 95.0 W 59.4 W 105.0 W 65.6 W 110.0 W 71.9 W N/A 78.1 W N/A 84.4 W N/A 89.0 W
Note: The thermal profile is used to define the relationship between Tcase max and device specific Thermal Design Power for Rev E processors specified in this document with Variable indicated by the Case Temperature OPN character.
86
N/A
N/A
87
1 1 2 2
2, 6 2, 6 3 4, 7 5 3 4, 7 5 3 4, 7 5 3 4, 7 5 3 4, 7 5 3 4, 7 5 3 4, 7 3 4, 7
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
88
2, 6 2, 6 3 4, 7 5 3 4, 7 5 3 4, 7 5 3 4, 7 5 3 4, 7 5 3 4, 7 5 3 4, 7 3 4, 7
N/A
N/A
N/A
N/A
89
Notes: 1 CPUID extended function 8000_0001h fields are used by BIOS in uniquely associating a given processor to the Pstates that are valid for that processor. Refer to the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094. 2 FIDVID Status Register, M SR C001_0042h. 3 The VID_VDD voltage is the VID[4:0] requested VDD supply level. Refer to the appropriate functional data sheet for details. 4 Thermal Design Power (TDP) is measured under the conditions of Tcase M ax, IDD M ax, and VDD=VID_VDD, and include all power dissipated on-die from VDD, VDDIO, VLDT, VTT, and VDDA. 5 Implementation of this P-state is optional in BIOS. 6 StartVID and M axVID are programmed during device manufacturing with part-specific values for Rev E and later processors, and can have one or more valid options. All valid options for StartVID, M axVID, and VID_VDD will be specified for the corresponding OPN. For information on the relationship of StartVID and M axVID to VID_VDD refer to the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094. Contact your FAE for more info on TDP specifications. 7 Thermal Design Power (TDP) specifications for dual core processors assume equivalent P-states (Voltage and frequency) and equivalent Tcase conditions for both cores. Refer to the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094, for details on P-state operation for dual core processors.
90
14 3 4, 15 11 3 4, 15 11 3 4, 15 11 3 4, 15 11 3 4, 15 11 3 4, 15 11 3 4, 15 3 4, 15 5, 16 6, 16 8, 12 7 7, 9, 12
N/A
N/A
N/A
N/A
N/A
91
14 3 4, 15 11 3 4, 15 11 3 4, 15 11 3 4, 15 11 3 4, 15 11 3 4, 15 11 3 4, 15 3 4, 15 5, 16 6, 16 8, 12 7 7, 9, 12
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
92
14 3 4, 15 11 3 4, 15 11 3 4, 15 11 3 4, 15 11 3 4, 15 11 3 4, 15 11 3 4, 15 3 4, 15 5, 16 6, 16 8, 12 7 7, 9, 12
N/A
N/A
N/A
N/A
93
Notes: 1. Tcase max is the maximum case temperature specification which is a physical value in degrees Celsius. This value is programmed into Rev D and later processors. Refer to the appropriate functional data sheet, and the THERM TRIP Status Register in the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094. 2. Tcontrol max (maximum control temperature) is a non physical temperature on an arbitrary scale that can be used for system thermal management policies. Tcontrol max represents the value at which the processor has reached Tcase max when measuring the thermal diode with a dual sourcing current temperature sensor. Refer to the appropriate functional data sheet, and the THERM TRIP Status Register in the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094. 3. The VID_VDD voltage is the VID[4:0] requested VDD supply level. Refer to the appropriate functional data sheet for details. 4. Thermal Design Power (TDP) is measured under the conditions of Tcase M ax, IDD M ax, and VDD=VID_VDD, and include all power dissipated on-die from VDD, VDDIO, VLDT, VTT, and VDDA. 5. Assumes Tcase max, max P-state VID_VDD, clock divider set to 32. 6. Assumes 50C, min P-state VID_VDD, clock divider set to 32. 7. Assumes 35C, VDD, VDDA, and VLDT supplies are off, VDDIO and VTT are powered, memory in selfrefresh mode and DDR SDRAM interface tri-stated except CKE pins. Refer to the appropriate functional data sheet for complete VDDIO and VTT power supply specifications. 8. Thermal Design Power dissipated by the processor VDDIO, VTT, VLDT, and VDDA power planes only. 9. Thermal Design Power dissipated by the processor VDDIO and VTT power planes only. 10. Refer to the AM D Athlon 64 Processor Desktop Power Roadmap, order #26882, for IDD M ax and Thermal Design Power requirements for future processor revisions. 11. Implementation of this P-state is optional in BIOS. 12. Assumes VDDIO = 2.6 V and VTT = VDDIO / 2. Refer to the appropriate functional data sheet for complete VDDIO and VTT power supply specifications. 13. Tcase max is programmed during device manufacturing with part-specific values for Rev E and later processors, and can be any valid Tcase max value in the range specified for the corresponding OPN. 14 Thermal Design Power (TDP) and IDD max for Rev E and later processors are the limits at the highest Tcase max in the specified range for the corresponding OPN. Products will conform to the TDP and IDD M ax limits at all valid voltages. The relationship of Tcase max and Thermal Profile to TDP for a specific device is defined in Table 44. 15 Thermal Design Power (TDP) specifications for dual core processors assume equivalent P-states (Voltage and frequency) and equivalent Tcase conditions for both cores. Refer to the BIOS and Kernel Developers Guide for AM D Athlon 64 and AM D Opteron Processors, order# 26094, for details on P-state operation for dual core processors. 16 IDDC1 specifications for dual core processors assume equivalent Voltage, clock divisor, and Tcase conditions for both cores.
94
MTOPS
Table 47 shows the Composite Theoretical Performance (CTP) calculations ("Calculations") for AMD Athlon 64, AMD Athlon 64 FX, AMD Athlon 64 X2 Dual Core and AMD Sempron microprocessors. The Calculations are stated in Millions of Theoretical Operations Per Second (MTOPS) and are based upon a formula in the United States Department of Commerce Export Administration Regulations 15 CFR 774 (Advisory Note 4 for Category 4). All Calculations contained herein are subject to change without notice. AMD makes no representation or warranty as to the accuracy or reliability of such Calculations. THESE CALCULATIONS ARE PROVIDED "AS IS" WITH NO WARRANTIES WHATSOEVER, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY, NONINFRINGEMENT, FITNESS FOR ANY PARTICULAR PURPOSE OR ANY WARRANTY OTHERWISE ARISING OUT OF AMD PROVIDING OR ANY PARTY'S USE OF THE CALCULATIONS. Furthermore, AMD shall have no liability for any losses or damages including direct, indirect, special or consequential, such as but not limited to, loss of anticipated profits or other economic loss occurring in connection with use of the Calculations. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted herein. Table 47: Composite Theoretical Performance (CTP) Calculations
Fre quency MTO PS Single -Core MTO PS Dual-Core
800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000
2,467 3,084 3,700 4,317 4,934 5,550 6,167 6,784 7,400 8,017 8,634 9,250
4,667 5,834 7,000 8,167 9,334 10,500 11,667 12,834 14,000 15,167 16,334 17,500
MTOPS
95