CM707

PROGRAMMABLE THERMOSTAT
PRODUCT SPECIFICATION SHEET
The CM707 thermostat is designed to provide automatic time and temperature control of heating systems in villas and apartments. It can be used as part of a system in conjunction with combiboilers, oil-burners and gas fired boilers, circulation pumps, thermal actuators, zone valves and electric heat systems (<5A). The CM707 is designed with the installer in mind and includes a moulded back-plate with trunking guides and wiring breakouts to make installation quick and easy. The CM707 large LCD display, button layout based on the same simple programming philosophy used on our acclaimed CM20 products and the introduction of an OK button makes it easier to install and more user friendly. The unit is ideal for consumers who want reliable precise temperature control from a modern looking, simple to program and easy to use product.

FEATURES
Attractive slim, modern styling makes it ideal for location in any type of home. 7 day heating program. Up to 4 daily independent time and temperature level changes let you set 4 time and temperatures pairs to suit your lifestyle. Temporary programmed temperature override to temporarily override the programmed temperature till the next switch point. Holiday button provides energy savings by reducing the temperature from 1 to 99 days when people are on holiday, returning to normal operation (AUTO or MANUAL) on the day of their return. Room Temperature Enquiry. EEPROM memory holds the user program indefinitely. OFF mode has an integral frost protection setting at minimum 5C (installer adjustable) so that pipes in the house will never freeze in winter. 24...230V 5A resistive, 2A inductive SPDT relay provides compatibility with most domestic central heating systems reducing the need to stock many different models. Battery powered by 2 x AA size (LR6) alkaline cells. Minimum battery life of 2 years with low battery warning indicator. Built-in default heating program.

Surface or wall box mounting options, with trunking guides and wiring breakouts to simplify installation. No installer links or special installer switches on the back of the unit mean no adjustment is required for combi-boilers and most domestic central heating systems. User Set-Up Mode allows extra functions to be set at the discretion of the user:

AM-PM or 24hr time display. Resetting the heating profile to factory default.

Installer Set-Up Mode allows extra functions to be set at the discretion of the installer to match the consumers applications and needs: Pump Exercise. Upper / Lower Set point Limit Adjust. Temperature offset. Minimum ON time. Cycle rate. Proportional Band Width.

Diagnostic Mode to assist in fault finding.

EN0H 8544 UK07 R08/05

CM707 CHRONOTHERM

CONTROLS/ DISPLAY LAYOUT

PRODUCT LAYOUT: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. LCD Screen Battery Low Indicator Time Display Burner On Indicator Day Indicator Temperature Display Temperature Change Buttons Information Enquiry Button Operating Mode Buttons Green OK Button Battery Compartment Battery Cover Holiday Function Button Program Buttons Copy Day Button Day Select Button Time Change Buttons

SPECIFICATIONS
Batteries Battery life Battery replacement Switch type Electrical rating : 2 x 1.5 V IEC LR6 (AA) Alkaline cells : Minimum 2 years : Program retained in EEPROM : SPDT (potential free) : 230 V~, 50...60 Hz, 0.1 A to 5 A resistive 0.1 A to 2 A inductive (0.6 pf) 24 V~, 50...60 Hz, 0.5 A to 5 A resistive 0.5 A to 2 A inductive (0.6 pf) : 24 hour or 12 hour AM/PM format : Typically better than 10 minutes per year : 7 day with 4 daily time and temperature level changes : Time of day - 1 minute Program - 10 minute steps
o

Temperature : 0.5 K (nominal) @ 20 C, 50% load control accuracy 3 K /hour


o

Room Temperature display range Control form Minimum ON time Cycle rate Wiring Wire access Dimensions

: From 0 C to 50 C
o o

: P + I (Proportional + Integral) : 10% of cycle time (min one minute), adjustable to 2 to 5 min (see installer set up) : Selectable by application (see installer set up) : Terminal block capable of accepting 2 wires up to 2.5 mm : Mains wiring rear right. Low voltage wiring rear right. : 133 x 88.5 x 26 mm (w x h x d) 133 x 175 x 26 mm (w x h x d) (flap open) : Operating temperature range 0 to 40 C Shipping and storage temperature range o -20 to 55 C Humidity range 10 to 90% rh, noncondensing
o

Time display Time keeping accuracy Program Time setting resolution

Sensing element : 100K (@ 25 C ) NTC thermistor Temperature setting range : Program : 5 to 35 C in 0.5 C steps o Frost : 5 C or equal to lower limit o o (5 C to 21 C).
o o

Environmental

Approvals

: Designed to meet European EN approvals EN60730-1(Nov 2000), EN55014-1 (1997), EN55014-2 (2000)

EN0H 8544 UK07 R08/05

CM707 CHRONOTHERM

INSTALLER SET-UP
To enter the installer set-up mode: a) Press the OFF button. b) Press and hold the INFO i button and the two program buttons < > together. c) The unit will display the first parameter of installer parameter group category 1 (from n.1 to n.19). or buttons to change the factory d) Press the TEMP setting. The display will flash indicating that a change has been made. e) Press the green OK button to confirm this change and the display will stop flashing. f) Press the + button to go to the next parameter.
Abbreviated Set-Up Description e.g. Cl = Clock Format

g) Press the program button > to go to category 2 in the Installer mode (from n.1 to n.5). h) To exit the installer mode, press the AUTO, MAN or OFF buttons.

Installer Set-up Number (Press + or - to change) e.g. 1 = Clock Format

In Installer set-up we can:


Set-up specific applications Enable special features

Factory Setting or New Choice Press TEMP or to change e.g. 12 = AM/PM Format 24 = 24hr Format

Specific Applications

Setting
Cycle/ Hour Minimum ON time
(in minutes)

What do you need to change?


Note : a. To change Cycle/Hour, please go to parameter n. 2, category 2 in the installer set-up mode. b. To change Minimum ON Time, please go to parameter n. 1, category 2 in the installer set-up mode. No action required 1. Set Minimum ON Time to 4 minutes. 2. Set Cycle/Hour to 3. Set Cycle/Hour to 12. No action required. Set Cycle/Hour to 12.

Heating

Gas Boilers (<30KW) Oil Boiler Thermal Actuator Zone valve Electric heating (for applications <5A)

6 3 12 6 12

1 4 1 1 1

EN0H 8544 UK07 R08/05

CM707 CHRONOTHERM

Special Features
AM-PM/ 24hr Display Pump exercise

Description
Change display format (default 24hr). When enabled the Pump Exercise will switch the relay on for 1 minute at 12:00 if the relay has not been switched on since 12:00 the previous day. While in Holiday mode the Pump Exercise feature, if enabled, will operate. The normal upper temperature limit of 35 C can be o reduced down to 21 C to save the homeowner energy. Useful if the homeowner rents to tenants. The normal lower temperature limit of 5 C can be o increased up to 21 C to protect the inhabitants from cold. Useful if the inhabitants include the elderly, children or disabled. If the thermostat is located in a hot/cold location and cannot be moved because of wiring then the measured/ o displayed temperature can be adjusted by +/- 3 C. Useful if the homeowner wants the reading to match another appliance temperature display. Can be adjusted up to 3 C (default is 1.5 C) to provide better temperature control (less overshoot). Useful for: a. Well insulated homes with over-sized heating systems. b. Air systems with fast response.
o o o o

What to do if we wish this feature


Set parameter n.1, category 1 in the installer set -up mode to 12. Set parameter n.5, category 2 in the installer set -up mode to 1.

Upper Temperature Limit

Set parameter n.6, category 1 in the installer set -up mode to the desired limit. Set parameter n.7, category 1 in the installer set -up mode to the desired limit. Set parameter n.12, category 1 in the installer set -up mode to the desired offset value.

Lower Temperature Limit

Temperature Offset

Proportional Band Width

Set parameter n.13, category 1 in the installer set -up mode to the desired value.

EN0H 8544 UK07 R08/05

CM707 CHRONOTHERM
Parameter Installer Set-Up Number / Abbreviation (Press + or keys to select) Display Category 1: Thermostat Parameters AM-PM / 24hr Display RESET Time / Temperature Program 1:Cl 2:rP 24 1 24 hr clock display Time / Temperature profile set to factory default Changes to 0 when one of the time/temp profiles are changed 35C Upper Temp. Limit 12 0 1 12 hr AM / PM clock display Time / Temperature are as programmed To restore the factory profile set to 1 1 1 Description Display/Setting Description Factory Setting Optional Setting Installer SetUp Category (Press PROG keys < or > to select)

Upper Temperature Limit Lower Temperature Limit Temperature Offset Proportional Band Width

6:uL

35

21 to 34

21C to 34C adjustment in 1C steps

7:LL

5C Lower Temp. Limit

6 to 21

6C to 21C adjustment in 1C steps

12:tO

No offset

-3 to +3

-3C to +3C adjustment in 0.1C steps 1.6C to 3.0C adjustment in 0.1C steps Settings are as modified above To restore the factory profile set to 1

13:Pb

1.5

1.5C Proportional Band

1.6 to 3.0

Reset Parameters to Factory Defaults

19:FS

All settings held are the factory defaults. Changes to 0 when one of the parameter values are changed

0 1

Category 2: System Parameters (You must press the > program key to enter this section) Minimum ON Time 1:Ot 1 1 minute minimum ON time 2 to 5 2 - 2 minutes 3 - 3 minutes 4 - 4 minutes 5 - 5 minutes 3 - 3 cph 9 - 9cph 12 - 12 cph Pump Exercise Enabled 2

Cycle Rate

2:Cr

6 cycles per hour (cph) for gas boilers, zone valves and fancoil Pump Exercise Disabled

3, 9, 12

Pump Exercise

5:PE

EN0H 8544 UK07 R08/05

CM707 CHRONOTHERM

DIMENSIONS

INSTALLATION
LOCATION
The CM707 thermostat is the control element of the heating system and, therefore, MUST be located in a position with good air circulation, at average room temperature and on an inside wall, 1.5 metres above the floor level. Do not position the CM707 thermostat near sources of heat (radiators, hot air vents, TV or lights), near doors or windows, or in direct sunlight.

MOUNTING
The CM707 thermostat can be mounted directly on the wall surface or on to an electrical wall box.

WIRING
The CM707 thermostat is designed for fixed wiring only and must be installed in accordance with the latest l.E.E. regulations. Ensure the wiring connection to the supply is via a fuse rated at no more than 5 amps and a Class "A" switch (having contact separation of at least 3 mm in all poles). IMPORTANT 1. The installer must be a trained service engineer. 2. Disconnect the power supply before beginning installation.

EN0H 8544 UK07 R08/05

CM707 CHRONOTHERM

WIRING

ORDERING SPECIFICATION
Description 7-day programmable thermostat Model CMT707A1003 Logo Honeywell Literature French, Dutch, Italian, Spanish, German, Portuguese. Czech, Polish, Slovakian, Hungarian, Romanian, Russian. Spec Sheet ENOH8544

CMT707A1011

Honeywell

ENOH8544

Honeywell Control Systems Limited Newhouse Industrial Estate Motherwell ML1 5SB United Kingdom

http://europe.hbc.honeywell.com

EN0H 8544 UK07 R08/05