IP-10 IDU Installation (Rev b.01)
IP-10 IDU Installation (Rev b.01)
IP-10 IDU Installation (Rev b.01)
Part ID: BM-0237-0 Doc ID: DOC-00018797 Rev b.01 January 2009
1-1
Notice
This document contains information that is proprietary to Ceragon Networks Ltd. No part of this publication may be reproduced, modified, or distributed without prior written authorization of Ceragon Networks Ltd. This document is provided as is, without warranty of any kind.
Registered TradeMarks
Ceragon Networks is a registered trademark of Ceragon Networks Ltd. FibeAir is a registered trademark of Ceragon Networks Ltd. CeraView is a registered trademark of Ceragon Networks Ltd. Other names mentioned in this publication are owned by their respective holders.
TradeMarks
CeraMap , PolyView , EncryptAir , ConfigAir , CeraMon , EtherAir , and MicroWave Fiber , are trademarks of Ceragon Networks Ltd. Other names mentioned in this publication are owned by their respective holders.
TM TM TM TM TM TM TM
Statement of Conditions
The information contained in this document is subject to change without notice. Ceragon Networks Ltd. shall not be liable for errors contained herein or for incidental or consequential damage in connection with the furnishing, performance, or use of this document or equipment supplied with it.
Information to User
Any changes or modifications of equipment not expressly approved by the manufacturer could void the users authority to operate the equipment and the warranty for such equipment. Copyright 2008 by Ceragon Networks Ltd. All rights reserved.
Corporate Corporate Headquarters: Ceragon Networks Ltd. 24 Raoul Wallenberg St. Tel Aviv 69719, Israel Tel: 972-3-645-5733 Fax: 972-3-645-5499 Email: [email protected] North American Headquarters: Ceragon Networks Inc. 10 Forest Avenue, Paramus, NJ 07652, USA Tel: 1-201-845-6955 Toll Free: 1-877-FIBEAIR Fax: 1-201-845-5665 Email: [email protected]
www.ceragon.com
European Headquarters: Ceragon Networks (UK) Ltd. 4 Oak Tree Park, Burnt Meadow Road North Moons Moat, Redditch, Worcestershire B98 9NZ, UK Tel: 44-(0)-1527-591900 Fax: 44-(0)-1527-591903 Email: [email protected] APAC Headquarters Ceragon Networks (HK) Ltd. Singapore RO Level 34 Centennial Tower 3 Temasek Avenue Singapore 039190 Tel - + 65 6549 7886 Fax: +65 6549 7011
1-2
Contents
Chapter 1: Installation ................................................................................... 1-4
General ................................................................................................................1-4 Site Requirements ..............................................................................................1-4 Pre-Installation....................................................................................................1-4 Unpacking Equipment at the Site ......................................................................1-5 Installation Requirements ..................................................................................1-5 FibeAir IP-10 Description ...................................................................................1-7 Installing the IDU in a Rack................................................................................1-8 Grounding the IDU............................................................................................1-10 Connecting the IDU ..........................................................................................1-12 TDM Interface Add-on Slots1-12 IP-10 Nodal Design....1-14 Configuring the IDU..........................................................................................1-16
Appendix A: Line Interfaces ....................................................................... 1-17 Appendix B: Connector Pin-Outs ............................................................... 1-21 Appendix C: Protection Information .......................................................... 1-27 Appendix D: Accesories.............................................................................. 1-30 Appendix E: Fan Tray Replacment............................................................. 1-33
1-3
Chapter 1: Installation
General
This chapter provides instructions for the installation of the FibeAir IP-10 IDU at the customer site.
Site Requirements
Must be located indoors. The environment temperature must be between -5 C and +55 C. Easily accessible, but only by authorized personnel. Available power source of -48 VDC, and the site must comply with National Electric Code (NEC) standards. Available management connection (Ethernet or dial-up). No more than 300 m from RFU location. In addition, since the IDU will be connected to the RFU, when considering a site, it is important to check for current and future obstacles on the roof or tower. Possible future obstacles may include trees, new buildings, window cleaners on the roof, snow that may accumulate in front of the antenna, etc. The site should be accessible to certified personnel only. Note about Heat Dissipation: The IP-10 IDU overall heat dissipation is 25W max (~85 BTU/h). Note about Antenna Location: As with any type of construction, a local permit may be required before installing an antenna. It is the owners responsibility to obtain any and all permits.
Pre-Installation
Packing
The equipment is packed at the factory, and sealed moisture-absorbing bags are inserted.
Transportation
The equipment is prepared for public transportation. The cargo must be kept dry during transportation, in accordance with ETS 300 019-1-2, Class 2.3. It is recommended to transport the equipment to the installation site in its original packing case. If intermediate storage is required, the packed equipment must be stored in dry and cool conditions and out of direct sunlight, in accordance with ETS 300 019-1-1, Class 1.2.
1-4
Inspection
Check the packing lists, and ensure that the correct part numbers and quantities of components arrived.
Installation Requirements
Required Tools
The following tools are required to install the IDU: Philips screwdriver (for mounting the IDU to the rack and grounding screw) Flathead small screwdriver (for PSU connector) Sharp cutting knife (for wire stripping) Crimping tool for ground cable lug crimping (optional: if alternative grounding cable is used).
Cables
In addition to the tools mentioned above, the interface connectors and their pin-outs, can be found in the following sections in this guide: Appendix A: Line Interfaces Appendix B: Connector Pin-Outs
1-5
1-6
1-7
As shown in the illustration, four screws, supplied with the installation kit, are used to secure the IDU to the rack.
1-8
IDU Dimensions The following illustration shows the dimensions (in millimeters) of the FibeAir IP-10 IDU.
1-9
A grounding wire is connected below the IDU-RFU interface using a single screw with two washers. IDU Grounding Notes The IDU is suitable for installation in a Common Bonding Network (CBN). Only copper wire should be used. The wire must be at least 6 AWG. Connector and connection surfaces must be plated. Bare conductors must be be coated with antioxidant before crimp connections are made to the screws. FibeAir provides a ground for each IDU, via a one-hole mounted lug onto a single-point stud. The stud must be installed using a UL-listed ring tongue terminal, and two star washers for anti-rotation.
1-10
For antenna ports, lightning protection is used that does not permit transients of a greater magnitude than the following: Open Circuit: 1.2-50us 600V Short Circuit: 8-20us 300A
The ampacity of the conductor connecting the IDU frame to the DC return conductor is equal to, or greater than, the ampacity of the associated DC return conductor.
Power Supply Notes When selecting a power source, the following must be considered: DC power can be from -40.5 VDC to -60 VDC. Recommended: Availability of a UPS (Uninterrupted Power Source), battery backup, and emergency power generator. Whether or not the power source provides constant power (i.e., power is secured on weekends or is shut off frequently and consistently). The power supply must have grounding points on the AC and DC sides.
Caution!
The user power supply GND must be connected to the positive pole in the IDU power supply. Any other connection may cause damage to the system! Power supply grounding should be in accordance with the following illustration:
1-11
Interface Descriptions
The following photo shows the different IDU ports and their functions.
External Alarms (DB9) Engineering order-wire (optional) User Channel (optional) (RJ45)
16 x E1/T1s (optional) Protection Interface (RJ45) 2 x GE combo ports Electrical (RJ45) or Optical (SFP) 5 x FE Electrical (RJ45)
The IDU front panel includes the following auxiliary interfaces: Terminal console Ethernet out-of-band management Ethernet wayside
1-12
Optional: Engineering Order Wire (EOW) User channel (V11, RS232) External alarms Note: The Fast Ethernet interface channels can be logically configured for either Fast Ethernet traffic, or protection, wayside, or management traffic.
The T-cards are field-upgradable, and add a new dimension to the FibeAir IP-10 migration flexibility.
16 x E1/T1 T-Card
1-13
A "blade" can operate as a stand-alone unit at a tail site. The "rack chassis" is also modular, for optimum economical future upgrade, network design flexibility, and efficient installation, maintenance, and expansion. The solution is modular and forms a single unified nodal device, with a common Ethernet Switch, common E1 Cross-Connect, single IP address, and a single element to manage.
1-14
1-15
1-16
1-17
Optional 16xE1/T1
Connector Used with: Interface Type Number of ports Timing mode: Framing Coding Range: Line Impedance Compatible Standards MDR 69-pin Twisted pair E1/T1 16 per unit (optional) Retimed Unframed (full transparency) E1: HDB3 T1: AMI/B8ZS 5m 120 /100 balanced. Optional module for 75 unbalanced ITU-T G.703, G.736, G.775, G.823, G.824, G.828, ITU-T I.432, ETSI ETS 300 147, ETS 300 417, ANSI T1.105, T1.102-1993, T1.231, Bellcore GR-253-core, TR-NWT-000499
10/100BaseT (Ethernet)
Connector: Used with: Protocols supported: Timing mode: Range: Impedance: Shielded RJ-45 UTP Cat 5 Ethernet (10/100BaseT), half or full duplex Retimed 100 m 100
1-18
1-19
1-20
1-21
Pin
1 2 3 4 5 6 7 8 9
Signal
EXT_IN5 EXT_IN4 EXT_IN3 EXT_IN2 EXT_IN1 GND RELAY_1_NO RELAY_1_C RELAY_1_NC
I/O
Input Input Input Input Input GND Output Output Output
Description
External input alarm #5 External input alarm #4 External input alarm #3 External input alarm #2 External input alarm #1 GND Relay #1, normally open pin Relay #1, common pin Relay #1, normally closed pin
Signal
Twisted Pair, In - Rx
Not Connected
Not Connected
1-22
Note that right/left refers to viewing the panel from the front.
16 x E1/T1 Connector
The 16 x E1/T1 connector is a SCSI 68-pin connector.
Label on the Twisted Pair
Ch1 Tx
Pin #
1 35 2 36 3 37 4 38 5 39 6 40 7 41 8 42 9 43 10 44 11
Signal
OUT - TIP1 OUT - RING1 OUT - TIP2 OUT - RING2 OUT - TIP3 OUT - RING3 OUT - TIP4 OUT - RING4 OUT - TIP5 OUT - RING5 OUT - TIP6 OUT - RING6 OUT - TIP7 OUT - RING7 OUT - TIP8 OUT - RING8 OUT - TIP9 OUT - RING9 OUT - TIP10 OUT - RING10 OUT - TIP11
Type
TWISTED PAIR
Ch2 Tx
TWISTED PAIR
Ch3 Tx
TWISTED PAIR
Ch4 Tx
TWISTED PAIR
Ch5 Tx
TWISTED PAIR
Ch6 Tx
TWISTED PAIR
Ch7 Tx
TWISTED PAIR
Ch8 Tx
TWISTED PAIR
Ch9 Tx
TWISTED PAIR
Ch10 Tx Ch11 Tx
1-23
45 12 46
Pin #
13 47 14 48 15 49 16 50 19 53 20 54 21 55 22 56 23 57 24 58 25 59 26 60 27 61 28 62 29 63 30
Signal
OUT - TIP13 OUT - RING13 OUT - TIP14 OUT - RING14 OUT - TIP15 OUT - RING15 OUT - TIP16 OUT - RING16 IN - TIP1 IN - RING1 IN - TIP2 IN - RING2 IN - TIP3 IN - RING3 IN - TIP4 IN - RING4 IN - TIP5 IN - RING5 IN - TIP6 IN - RING6 IN - TIP7 IN - RING7 IN - TIP8 IN - RING8 IN - TIP9 IN - RING9 IN - TIP10 IN - RING10 IN - TIP11 IN - RING11 IN - TIP12
Type
TWISTED PAIR
Ch14 Tx
TWISTED PAIR
Ch15 Tx
TWISTED PAIR
Ch16 Tx
TWISTED PAIR
Ch1 Rx
TWISTED PAIR
Ch2 Rx
TWISTED PAIR
Ch3 Rx
TWISTED PAIR
Ch4 Rx
TWISTED PAIR
Ch5 Rx
TWISTED PAIR
Ch6 Rx
TWISTED PAIR
Ch7 Rx
TWISTED PAIR
Ch8 Rx
TWISTED PAIR
Ch9 Rx
TWISTED PAIR
Ch10 Rx
TWISTED PAIR
Ch11 Rx Ch12 Rx
1-24
64 31 65 32 66
Ch14 Rx
TWISTED PAIR
Pin #
33 67 34 68 17 18 51 52
Signal
IN - TIP15 IN - RING15 IN - TIP16 IN - RING16 SHELL SHELL SHELL SHELL
Type
TWISTED PAIR
Ch16 Rx -
Signal
1-25
Signal
Twisted Pair, In - Rx
Not Connected
Not Connected
Asynchronous RS-232
NC NC NC GND Signal Ground UC_RS232_TXD Transmitted Data UC_RS232_RXD Received Data NC NC
Asynchronous V11
UC_TXD_P UC_TXD_N NC GND Signal Ground NC
I/O
Out Out NC COM
Out
6 7 8
NC UC_RXD_P UC_RXD_N
In In In
1-26
As shown in the illustration above, the protection panel (in the middle) provides the ports used to link the two IP-10 units for protection switching when a system fault occurs.
1-27
Panel Components
The following illustration shows the panel components.
User 16xE1/T1 Open-Ended MDR Connector IDU #1 4 x FE Straight RJ-45 Connectors User FE Open-Ended Cross RJ-45 Connectors
Part Numbers
The part numbers for the MDR cables are as follows: 16 x E1/T1 MDR Connector: WA-0276-0, 0.6 meters User 16 x E1/T1 MDR Connector: WA-0277-0, 5 meters WA-0278-0, 10 meters WA-0309-0, 25 meters Optical splitter used for GbE 1+1 systems (see the following section): AO-0038-0 AO-0039-0 AO-0059-0 AO-0060-0
1-28
Optical Splitter
1-29
Appendix D: Accessories
The following tables list the FibeAir IP-10 accessories.
Cables
Part Number WA-0242-1 WA-0246 WA-0259 WA-0275 WA-0276-0 WA-0277-0 WA-0278-0 WA-0284-0 WA-0309-0 Marketing Model X-WSC-E1/T1 IDU-EXT-ALARMS-CBL-2.5m CBL-16E1-CB-120-75 IDU-UC-CBL-2m IP10-CBL-16IO-PROT-0.6m IP10-CBL-16IO-5M IP-10-CBL-16IO-10M IP10-CBL-16IO-XED-0.6m IP-10-CBL-16IO-25M Marketing Description E1/T1 WSC x-ed cable IDU External Alarms open cable 2.5m 16E1 cable MDR/2xDB44 5m to CB-120-75 User channel cable 2m D-type 9 pin male IP-10 16 I/O port protection cable straight 0.6m IP-10 16 I/O port cable open 5M IP-10 16 I/O port cable open 10M IP-10 16 I/O port crossed cable 0.6m IP-10 16 I/O port cable open 25M
Panels
Part Number EN-0254-0 EN-0256-0 EN-0258-0 EN-0259-0 EN-0262-0 Marketing Model IP10-ETH-16E1-PROT-PANEL IP10-ETH-16T1-PROT-PANEL IP10-16E1-PROT-PANEL IP10-16T1-PROT-PANEL IP10-ETH-PROT-PANEL Marketing Description IP-10 Eth + 16E1 protection panel IP-10 Eth + 16T1 protection panel IP-10 16E1 protection panel IP-10 16T1 protection panel IP-10 Eth only protection panel
1-30
Optical Splitters
Part Number AO-0038-0 Marketing Model GBE-SPL-SM Marketing Description SM/LC Optical Splitter conn. 1300nm 50/5 MM/LC Optical Splitter 62.5/125 2M MM/LC Optical Splitter 62.5/125 1M MM/LC Optical Splitter 62.5/125 0.6M Item Description 1x2 Single mode Fiber Dual Windows Wideband Couplers, 40nm, LC/LC, 1310nm,1m length, PVC 2.0mm cable (yellow), 50/50 coupling ratio. 1x2 multimode mode Fiber Dual Windows Wideband Couplers, 40nm, LC/LC, 850nm,1m length for each port, PVC 2.0mm cable, 50/50 coupling ratio 1x2 multimode mode Fiber Dual Windows Wideband Couplers, 40nm, LC/LC, 850nm,0.5m length for each port, PVC 2.0mm cable, 50/50 coupling ratio 1x2 multimode mode Fiber Dual Windows Wideband Couplers, 40nm, LC/LC, 850nm,0.3m length for each port, PVC 2.0mm cable, 50/50 coupling ratio
AO-0039-0
GBE-SPL-MM-2M
AO-0059-0
GBE-SPL-MM-1M
AO-0060-0
GBE-SPL-MM-0.6M
Optical Cables
Part Number AO-0033-0 Marketing Model OP-SM-CBL-LC-SCDPLX 15M Marketing Description Duplex Optical Cable LC-SC SM 15M Duplex Optical Cable LC-SC SM 3M Duplex Optical Cable LC-SC SM 1m Duplex Optical Cable LC-SC MM 2M Duplex Optical Cable LC-SC MM 10M Duplex Optical Cable LC-LC MM 0.5M Duplex Optical Cable LC-SC SM 10m Item Description Pairs of Fiber Patchcord Single mode- LC/SC, Length:15M, Duplex PVC 2mm cable, with LC connector type on one end and SC connector on the other end. Pairs of Fiber Patchcord Single mode- LC/SC, Length:3M, Duplex PVC 2mm cable, with LC connector type on one end and SC connector on the other end. DUPLEX LC-SC (Tx TO Tx) SM 9/125 YELLOW COLOR R-9D-1-P, 13MM, 1M DUPLEX FIBER OPTIC MM PATCH CORD WITH LC/UPC-SC/UPC (Tx TO Tx) 62.5/125, ORANGE COLOR, 2M, 3MM O.D. DUPLEX FIBER OPTIC MM PATCH CORD WITH LC/UPC-SC/UPC (Tx TO Tx) 62.5/125, ORANGE COLOR, 10M, 3MM O.D. DUPLEX FIBER OPTIC MM PATCH CORD WITH LC/UPC-LC/UPC (Tx TO Tx) 62.5/125 ORANGE COLOR, 0.5M, 2MM O.D. DUPLEX LC-SC (Tx TO Tx) SM 9/125 YELLOW COLOR, 3MM, 10M
AO-0035-0
AO-0041-0
AO-0044-0
AO-0045-0
AO-0048-0
AO-0055-0
1-31
Marketing Description Duplex Optical Cable LC-SC SM 5m Duplex Optical Cable LC-LC MM 3M Duplex Optical Cable LC-LC MM 6M Duplex Optical Cable LC-LC SM 3M
Item Description DUPLEX LC-SC (Tx TO Tx) SM 9/125 YELLOW COLOR, 3MM, 5M DUPLEX FIBER OPTIC MM PATCH CORD WITH LC/UPC-LC/UPC (Tx TO Tx) 62.5/125 ORANGE COLOR, 3M, 2MM O.D. DUPLEX FIBER OPTIC MM PATCH CORD WITH LC/UPC-LC/UPC (Tx TO Tx) 62.5/125 ORANGE COLOR, 6M, 2MM O.D. Pairs of Fiber Patchcord Single mode- LC/LC, Length:3M, Duplex PVC 2mm cable, with LC connector type on one end and LC connector on the other end.
AO-0066-0
AO-0067-0
AO-0071-0
Optical Adaptors
Part Number AO-0042-0 Marketing Model OP-SM-LC-LCADPT-SMPLX Marketing Description Adaptor Female/Female LC-LC Simplex Item Description SM SIMPLEX LC-LC SM ADAPTOR
1-32
1-33