FibeAir IP-10

IDU Installation Guide

Part ID: BM-0237-0 Doc ID: DOC-00018797 Rev b.01 January 2009

1-1

Notice
This document contains information that is proprietary to Ceragon Networks Ltd. No part of this publication may be reproduced, modified, or distributed without prior written authorization of Ceragon Networks Ltd. This document is provided as is, without warranty of any kind.

Registered TradeMarks
Ceragon Networks is a registered trademark of Ceragon Networks Ltd. FibeAir is a registered trademark of Ceragon Networks Ltd. CeraView is a registered trademark of Ceragon Networks Ltd. Other names mentioned in this publication are owned by their respective holders.

TradeMarks
CeraMap , PolyView , EncryptAir , ConfigAir , CeraMon , EtherAir , and MicroWave Fiber , are trademarks of Ceragon Networks Ltd. Other names mentioned in this publication are owned by their respective holders.
TM TM TM TM TM TM TM

Statement of Conditions
The information contained in this document is subject to change without notice. Ceragon Networks Ltd. shall not be liable for errors contained herein or for incidental or consequential damage in connection with the furnishing, performance, or use of this document or equipment supplied with it.

Information to User
Any changes or modifications of equipment not expressly approved by the manufacturer could void the users authority to operate the equipment and the warranty for such equipment. Copyright 2008 by Ceragon Networks Ltd. All rights reserved.

Corporate Corporate Headquarters: Ceragon Networks Ltd. 24 Raoul Wallenberg St. Tel Aviv 69719, Israel Tel: 972-3-645-5733 Fax: 972-3-645-5499 Email: [email protected] North American Headquarters: Ceragon Networks Inc. 10 Forest Avenue, Paramus, NJ 07652, USA Tel: 1-201-845-6955 Toll Free: 1-877-FIBEAIR Fax: 1-201-845-5665 Email: [email protected]

www.ceragon.com

European Headquarters: Ceragon Networks (UK) Ltd. 4 Oak Tree Park, Burnt Meadow Road North Moons Moat, Redditch, Worcestershire B98 9NZ, UK Tel: 44-(0)-1527-591900 Fax: 44-(0)-1527-591903 Email: [email protected] APAC Headquarters Ceragon Networks (HK) Ltd. Singapore RO Level 34 Centennial Tower 3 Temasek Avenue Singapore 039190 Tel - + 65 6549 7886 Fax: +65 6549 7011

FibeAir IP-10 IDU Installation Guide

1-2

Contents
Chapter 1: Installation ................................................................................... 1-4
General ................................................................................................................1-4 Site Requirements ..............................................................................................1-4 Pre-Installation....................................................................................................1-4 Unpacking Equipment at the Site ......................................................................1-5 Installation Requirements ..................................................................................1-5 FibeAir IP-10 Description ...................................................................................1-7 Installing the IDU in a Rack................................................................................1-8 Grounding the IDU............................................................................................1-10 Connecting the IDU ..........................................................................................1-12 TDM Interface Add-on Slots1-12 IP-10 Nodal Design....1-14 Configuring the IDU..........................................................................................1-16

Appendix A: Line Interfaces ....................................................................... 1-17 Appendix B: Connector Pin-Outs ............................................................... 1-21 Appendix C: Protection Information .......................................................... 1-27 Appendix D: Accesories.............................................................................. 1-30 Appendix E: Fan Tray Replacment............................................................. 1-33

FibeAir IP-10 IDU Installation Guide

1-3

Chapter 1: Installation
General
This chapter provides instructions for the installation of the FibeAir IP-10 IDU at the customer site.

Site Requirements
Must be located indoors. The environment temperature must be between -5 C and +55 C. Easily accessible, but only by authorized personnel. Available power source of -48 VDC, and the site must comply with National Electric Code (NEC) standards. Available management connection (Ethernet or dial-up). No more than 300 m from RFU location. In addition, since the IDU will be connected to the RFU, when considering a site, it is important to check for current and future obstacles on the roof or tower. Possible future obstacles may include trees, new buildings, window cleaners on the roof, snow that may accumulate in front of the antenna, etc. The site should be accessible to certified personnel only. Note about Heat Dissipation: The IP-10 IDU overall heat dissipation is 25W max (~85 BTU/h). Note about Antenna Location: As with any type of construction, a local permit may be required before installing an antenna. It is the owners responsibility to obtain any and all permits.

Pre-Installation
Packing
The equipment is packed at the factory, and sealed moisture-absorbing bags are inserted.

Transportation
The equipment is prepared for public transportation. The cargo must be kept dry during transportation, in accordance with ETS 300 019-1-2, Class 2.3. It is recommended to transport the equipment to the installation site in its original packing case. If intermediate storage is required, the packed equipment must be stored in dry and cool conditions and out of direct sunlight, in accordance with ETS 300 019-1-1, Class 1.2.

FibeAir IP-10 IDU Installation Guide

1-4

Inspection
Check the packing lists, and ensure that the correct part numbers and quantities of components arrived.

Unpacking Equipment at the Site


A single FibeAir system (1+0) is shipped in 5 crates. Upon delivery, make sure that the following items are included: Two indoor units and accessories Two outdoor units For 13-38 GHz systems, verify that there is a high RFU and low RFU. One CD with a management user guide. Unpack the contents and check for damaged or missing parts. If any part is damaged or missing, contact your local distributor.

Installation Requirements
Required Tools
The following tools are required to install the IDU: Philips screwdriver (for mounting the IDU to the rack and grounding screw) Flathead small screwdriver (for PSU connector) Sharp cutting knife (for wire stripping) Crimping tool for ground cable lug crimping (optional: if alternative grounding cable is used).

Cables
In addition to the tools mentioned above, the interface connectors and their pin-outs, can be found in the following sections in this guide: Appendix A: Line Interfaces Appendix B: Connector Pin-Outs

FibeAir IP-10 IDU Installation Guide

1-5

Requirements for North America


Restricted Access Area: DC powered equipment should only be installed in a Restricted Access Area. Installation Codes: The equipment must be installed according to country national electrical codes. For North America, equipment must be installed in accordance to the US National Electrical Code, Articles 11016, 110-17 and 110-18, and the Canadian Electrical Code, Section 12. Overcurrent Protection: A readily accessible Listed branch circuit overcurrent protective device, rated 15 A, must be incorporated in the building wiring. CAUTION: This equipment is designed to permit connection between the earthed conductor of the DC supply circuit and the earthing conductor at the equipment. Grounded Supply System: The equipment shall be connected to a properly grounded supply system. All equipment in the immediate vicinity shall be grounded the same way, and shall not be grounded elsewhere. Local Supply System: The DC supply system is to be local, i.e. within the same premises as the equipment. Disconnect Device: A disconnect device is not allowed in the grounded circuit between the DC supply source and the frame/grounded circuit connection.

FibeAir IP-10 IDU Installation Guide

1-6

FibeAir IP-10 Description


FibeAir IP-10 is Ceragon's comprehensive high capacity migration-to-IP network solution. The innovative IP10 was designed as a native Ethernet microwave radio platform that can integrate smoothly in any network, while providing a broad range of software-configurable licensed channel schemes. IP-10 follows in the tradition of Ceragon's Native2, which allows your network to benfit from both native TDM and native Ethernet using the same radio. Flexible bandwidth sharing between the TDM and Ethernet traffic ensures optimal throughput for all your media transfer needs. IP-10 features a flexible design capable of addressing all network migration scenarios. With its Native2 capability for optimal traffic delivery, and modular architecture for all sites (Tail, Chain, Agg3, Agg2), this state-of-the-art radio platform offers the best approach to IP migration for advanced networks. With the widest capacity range (10-500 Mbps) for all capacity needs, advanced Adaptive Code Modulation for the best spectrum utilization, and a scalable system that ensures future-proof network expansion, IP-10 is the ideal solution for risk-free migration. Some of the important points that place IP-10 at the top of the wireless IP market include: Supports all licensed bands, from 6 to 38 GHz Supports channel bandwidths of from 7 MHz to 56 MHz Supports throughputs of from 10 to 500 Mbps per radio carrier (QPSK to 256 QAM) Incorporates advanced integrated Ethernet switching capabilities In addition, using unique Adaptive Code & Modulation (ACM), your network benefits from non-stop, dependable capacity deliverance.

FibeAir IP-10 IDU

FibeAir IP-10 IDU Installation Guide

1-7

Installing the IDU in a 19"/ETSI Rack


Warning! The intra-building port(s) of the equipment or subassembly is suitable for connection to intra-building or exposed wiring or cabling only. The intra-building port(s) of the eqiupment or subassembly MUST NOT be metallically connected to interfaces that connect to the OSP or its wiring. These interfaces are designed for use as intra-building interfaces only and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.
The FibeAir IP-10 IDU is installed in a standard 19" ETSI rack as shown in the following illustration.

As shown in the illustration, four screws, supplied with the installation kit, are used to secure the IDU to the rack.

FibeAir IP-10 IDU Installation Guide

1-8

IDU Dimensions The following illustration shows the dimensions (in millimeters) of the FibeAir IP-10 IDU.

FibeAir IP-10 IDU Installation Guide

1-9

Grounding the IDU


The following illustration shows how the IDU is grounded to the rack.

Single Point Stud Grounding Wire

A grounding wire is connected below the IDU-RFU interface using a single screw with two washers. IDU Grounding Notes The IDU is suitable for installation in a Common Bonding Network (CBN). Only copper wire should be used. The wire must be at least 6 AWG. Connector and connection surfaces must be plated. Bare conductors must be be coated with antioxidant before crimp connections are made to the screws. FibeAir provides a ground for each IDU, via a one-hole mounted lug onto a single-point stud. The stud must be installed using a UL-listed ring tongue terminal, and two star washers for anti-rotation.

FibeAir IP-10 IDU Installation Guide

1-10

For antenna ports, lightning protection is used that does not permit transients of a greater magnitude than the following: Open Circuit: 1.2-50us 600V Short Circuit: 8-20us 300A

The ampacity of the conductor connecting the IDU frame to the DC return conductor is equal to, or greater than, the ampacity of the associated DC return conductor.

Power Supply Notes When selecting a power source, the following must be considered: DC power can be from -40.5 VDC to -60 VDC. Recommended: Availability of a UPS (Uninterrupted Power Source), battery backup, and emergency power generator. Whether or not the power source provides constant power (i.e., power is secured on weekends or is shut off frequently and consistently). The power supply must have grounding points on the AC and DC sides.

Caution!
The user power supply GND must be connected to the positive pole in the IDU power supply. Any other connection may cause damage to the system! Power supply grounding should be in accordance with the following illustration:

FibeAir IP-10 IDU Installation Guide

1-11

Connecting the IDU


This section describes how the IDU interfaces are connected for a 1+0 system. The interfaces include line, system (IDU-RFU), and management ports. For interface specifications, see Appendix A - Line Interfaces and Cables. For connector pin-outs, see Appendix B - Connector Pin-Outs. For a list of accessories, see Appendix D - Accessories. Note: For a 1+1 system, a protection panel is used, as described in Appendix C - Protection Information.

Interface Descriptions
The following photo shows the different IDU ports and their functions.

IDU Front Panel


TDM interfaces add-on slot Fans drawer

External Alarms (DB9) Engineering order-wire (optional) User Channel (optional) (RJ45)

16 x E1/T1s (optional) Protection Interface (RJ45) 2 x GE combo ports Electrical (RJ45) or Optical (SFP) 5 x FE Electrical (RJ45)

RFU interface (N-Type)

GND Power -48V DC

The IDU front panel includes the following auxiliary interfaces: Terminal console Ethernet out-of-band management Ethernet wayside

FibeAir IP-10 IDU Installation Guide

1-12

Optional: Engineering Order Wire (EOW) User channel (V11, RS232) External alarms Note: The Fast Ethernet interface channels can be logically configured for either Fast Ethernet traffic, or protection, wayside, or management traffic.

TDM Interface Add-on Slots:


FibeAir IP-10 Release 2 supports TDM interface expansion cards ("T-cards") for: 16 x E1s/T1s (32 total per unit) STM-1/OC-3 (terminal mux for up to 63 E1s or 84 T1s) Supported TDM Expansion Card Types

The T-cards are field-upgradable, and add a new dimension to the FibeAir IP-10 migration flexibility.
16 x E1/T1 T-Card

FibeAir IP-10 IDU Installation Guide

1-13

IP-10 Nodal Design


IP-10 design for the nodal solution is based on a "blade" approach. Viewing the unit from the rear, each IDU can be considered a "blade" within a nodal enclosure.

A "blade" can operate as a stand-alone unit at a tail site. The "rack chassis" is also modular, for optimum economical future upgrade, network design flexibility, and efficient installation, maintenance, and expansion. The solution is modular and forms a single unified nodal device, with a common Ethernet Switch, common E1 Cross-Connect, single IP address, and a single element to manage.

FibeAir IP-10 IDU Installation Guide

1-14

Nodal Design Types


The following types of nodal enclosures are supported:

Modular Rack Chassis


The nodal enclosure is a scalable unit. Each enclosure can be added to another enclosure for modular rack installation.

FibeAir IP-10 IDU Installation Guide

1-15

IDU-ODU/RFU Coax Cable


The Coax Cable that connects between the IDU and the ODU/RFU should be terminated with N-type male connectors. Important! Make sure that the inner pin of the connector does not exceed the edge of the connector. The cable should have a maximum attenuation of 30 dB at 350 MHz.

Configuring the IDU


After the system is installed and tested, and antenna alignment is performed, the next step is IDU setup and configuration. Setup procedures are performed using the FibeAir IP-10 CLI (Command Line Interface) or Web Based Management. For an explanation of the CLI, see the FibeAir IP-10 CLI Guide. For an explanation of the Web Based Management, see the FibeAir IP-10 Web Based Management Guide.

FibeAir IP-10 IDU Installation Guide

1-16

Appendix A: Line Interfaces


This section provides a description of the FibeAir main channel, wayside channel, and order wire channel interfaces. The interfaces are located on the FibeAir IDU front panel. The following interface terms should be noted: For connectors or signals labeled TX, the signals are sent from FibeAir. For connectors or signals labeled RX, the signals are sent to FibeAir.

Main Channel Interfaces


Main channel interfaces include the following:

Gigabit Ethernet (Optical)


1000Base-SX (Multi Mode) Wavelength: Receptacle: Connector: Max Segment Length: Cable Type: 850 nm MSA compliant, SFP (Small Form Factor Pluggable Ports) LC 220 m (1351 ft), 500 m (1650 ft) For Max Segment = 220 m: 62.5 m MMF For Max Segment = 500 m: 50 m MMF 1000Base-LX (Single Mode) Wavelength: Receptacle: Connector: Max Segment Length: Cable Type: 1350 nm MSA compliant, SFP (Small Form Factor Pluggable Ports) LC 550 m (1805 ft), 5000 m (16404 ft) For Max Segment = 550 m: 62.5 m MMF, 50 m MMF For Max Segment = 5000 m: 10 m SMF

FibeAir IP-10 IDU Installation Guide

1-17

Gigabit Ethernet / Fast Ethernet (Electrical)


100/1000BaseT (Twisted Pair Cable) Connector: Max Segment Length: Cable Type: RJ-45 Up to 100 m (328 ft) per IEEE802.3 Compatible with shielded and unshielded twisted pair category 5 cables.

Optional 16xE1/T1
Connector Used with: Interface Type Number of ports Timing mode: Framing Coding Range: Line Impedance Compatible Standards MDR 69-pin Twisted pair E1/T1 16 per unit (optional) Retimed Unframed (full transparency) E1: HDB3 T1: AMI/B8ZS 5m 120 /100 balanced. Optional module for 75 unbalanced ITU-T G.703, G.736, G.775, G.823, G.824, G.828, ITU-T I.432, ETSI ETS 300 147, ETS 300 417, ANSI T1.105, T1.102-1993, T1.231, Bellcore GR-253-core, TR-NWT-000499

Wayside Channel Interface


The wayside channel is used as an auxiliary audio or data channel.

10/100BaseT (Ethernet)
Connector: Used with: Protocols supported: Timing mode: Range: Impedance: Shielded RJ-45 UTP Cat 5 Ethernet (10/100BaseT), half or full duplex Retimed 100 m 100

FibeAir IP-10 IDU Installation Guide

1-18

Protection Channel Interface


Protection
Connector: Used with: Protocols supported: Timing mode: Range: Impedance: Shielded RJ-45 UTP Cat 5 Ethernet (10/100BaseT), half or full duplex Retimed 100 m 100

Management Channel Interface


Out-of-Band Management
Connector: Used with: Protocols supported: Timing mode: Range: Impedance: Shielded RJ-45 UTP Cat 5 Ethernet (10/100BaseT), half or full duplex Retimed 100 m 100

Order Wire Channel Interface


The Order Wire is used for audio transmission for testing or maintenance purposes. The specifications for this channel are as follows:
Termination Type: Frequency band (KHz) Input impedance (ohms) Output impedance (ohms) Headset stereo plug, 2.5 mm 0.3-3.4 ~2000 32

FibeAir IP-10 IDU Installation Guide

1-19

User Channel Interface


The user channel is a CVSD audio channel that delivers 64 Kbps, via an RJ-45 connector. The interface can be used for one of the following: Asynchronous RS-232 Asynchronous V-11 Co and Contra Directional

FibeAir IP-10 IDU Installation Guide

1-20

Appendix B: Connector Pin-Outs


General
This appendix provides pin-outs for FibeAir IDU connectors, including the following: External Alarms Connector Protection/Wayside/Management Connector Power Connector 16 x E1/T1 Connector Ethernet 10/100/1000 Connector Ethernet 10/100 Connector User Channel Connector

FibeAir IP-10 IDU Installation Guide

1-21

External Alarms Connector Pin-Out


The External Alarms connector is a D-type 9-pin connector.

Pin
1 2 3 4 5 6 7 8 9

Signal
EXT_IN5 EXT_IN4 EXT_IN3 EXT_IN2 EXT_IN1 GND RELAY_1_NO RELAY_1_C RELAY_1_NC

I/O
Input Input Input Input Input GND Output Output Output

Description
External input alarm #5 External input alarm #4 External input alarm #3 External input alarm #2 External input alarm #1 GND Relay #1, normally open pin Relay #1, common pin Relay #1, normally closed pin

Protection/Wayside/Management Connector Pin-Out


The Protection/Wayside/Management connector is an RJ-45, 8-pin, female type connector.
RJ-45 Male Connector Pin
1 2 3 6 4 5 7 8

Signal

Twisted Pair, Out - Tx

Twisted Pair, In - Rx

Not Connected

Not Connected

FibeAir IP-10 IDU Installation Guide

1-22

Power Connector Pin-Out


The power connector pin-out is as follows:
Left Pin (#1) -48V (return current) Right Pin (#2) 0V

Note that right/left refers to viewing the panel from the front.

16 x E1/T1 Connector
The 16 x E1/T1 connector is a SCSI 68-pin connector.
Label on the Twisted Pair
Ch1 Tx

Pin #
1 35 2 36 3 37 4 38 5 39 6 40 7 41 8 42 9 43 10 44 11

Signal
OUT - TIP1 OUT - RING1 OUT - TIP2 OUT - RING2 OUT - TIP3 OUT - RING3 OUT - TIP4 OUT - RING4 OUT - TIP5 OUT - RING5 OUT - TIP6 OUT - RING6 OUT - TIP7 OUT - RING7 OUT - TIP8 OUT - RING8 OUT - TIP9 OUT - RING9 OUT - TIP10 OUT - RING10 OUT - TIP11

Type
TWISTED PAIR

Ch2 Tx

TWISTED PAIR

Ch3 Tx

TWISTED PAIR

Ch4 Tx

TWISTED PAIR

Ch5 Tx

TWISTED PAIR

Ch6 Tx

TWISTED PAIR

Ch7 Tx

TWISTED PAIR

Ch8 Tx

TWISTED PAIR

Ch9 Tx

TWISTED PAIR

Ch10 Tx Ch11 Tx

TWISTED PAIR TWISTED PAIR

FibeAir IP-10 IDU Installation Guide

1-23

45 12 46

OUT - RING11 OUT - TIP12 OUT - RING12 Ch12 Tx TWISTED PAIR

Pin #
13 47 14 48 15 49 16 50 19 53 20 54 21 55 22 56 23 57 24 58 25 59 26 60 27 61 28 62 29 63 30

Signal
OUT - TIP13 OUT - RING13 OUT - TIP14 OUT - RING14 OUT - TIP15 OUT - RING15 OUT - TIP16 OUT - RING16 IN - TIP1 IN - RING1 IN - TIP2 IN - RING2 IN - TIP3 IN - RING3 IN - TIP4 IN - RING4 IN - TIP5 IN - RING5 IN - TIP6 IN - RING6 IN - TIP7 IN - RING7 IN - TIP8 IN - RING8 IN - TIP9 IN - RING9 IN - TIP10 IN - RING10 IN - TIP11 IN - RING11 IN - TIP12

Label on the Twisted Pair


Ch13 Tx

Type
TWISTED PAIR

Ch14 Tx

TWISTED PAIR

Ch15 Tx

TWISTED PAIR

Ch16 Tx

TWISTED PAIR

Ch1 Rx

TWISTED PAIR

Ch2 Rx

TWISTED PAIR

Ch3 Rx

TWISTED PAIR

Ch4 Rx

TWISTED PAIR

Ch5 Rx

TWISTED PAIR

Ch6 Rx

TWISTED PAIR

Ch7 Rx

TWISTED PAIR

Ch8 Rx

TWISTED PAIR

Ch9 Rx

TWISTED PAIR

Ch10 Rx

TWISTED PAIR

Ch11 Rx Ch12 Rx

TWISTED PAIR TWISTED PAIR

FibeAir IP-10 IDU Installation Guide

1-24

64 31 65 32 66

IN - RING12 IN - TIP13 IN - RING13 IN - TIP14 IN - RING14 Ch13 Rx TWISTED PAIR

Ch14 Rx

TWISTED PAIR

Pin #
33 67 34 68 17 18 51 52

Signal
IN - TIP15 IN - RING15 IN - TIP16 IN - RING16 SHELL SHELL SHELL SHELL

Label on the Twisted Pair


Ch15 Rx

Type
TWISTED PAIR

Ch16 Rx -

TWISTED PAIR SHIELD SHIELD SHIELD SHIELD

Ethernet 10/100/1000 Connector Pin-Out


The Ethernet 10/100/1000 connector is an RJ-45, 8-pin, female type connector.
RJ-45 Female Connector Pin
1 2 3 6 4 5 7 8

Signal

Twisted Pair (Tx & Rx)

Twisted Pair (Tx & Rx)

Twisted Pair (Tx & Rx)

Twisted Pair (Tx & Rx)

FibeAir IP-10 IDU Installation Guide

1-25

Ethernet 10/100 Connector Pin-Out


The Ethernet 10/100 connector is an RJ-45, 8-pin, female type connector.
RJ-45 Female Connector Pin
1 2 3 6 4 5 7 8

Signal

Twisted Pair, Out - Tx

Twisted Pair, In - Rx

Not Connected

Not Connected

User Channel Connector Pin-Out


The user channel connector is an RJ-45 connector.
Pin
1 2 3 4

Asynchronous RS-232
NC NC NC GND Signal Ground UC_RS232_TXD Transmitted Data UC_RS232_RXD Received Data NC NC

Asynchronous V11
UC_TXD_P UC_TXD_N NC GND Signal Ground NC

I/O
Out Out NC COM

Out

6 7 8

NC UC_RXD_P UC_RXD_N

In In In

FibeAir IP-10 IDU Installation Guide

1-26

Appendix C: Protection Information


General
This appendix provides information about the FibeAir IP-10 protection equipment.

Protection Patch Panel


In IP-10 protection configurations, a protection patch panel is used to connect the units and provide protection switching.

As shown in the illustration above, the protection panel (in the middle) provides the ports used to link the two IP-10 units for protection switching when a system fault occurs.

FibeAir IP-10 IDU Installation Guide

1-27

Panel Components
The following illustration shows the panel components.
User 16xE1/T1 Open-Ended MDR Connector IDU #1 4 x FE Straight RJ-45 Connectors User FE Open-Ended Cross RJ-45 Connectors

IDU #1 16xE1/T1 MDR Connector

IDU #2 16xE1/T1 MDR Connector

IDU #2 4 x FE Straight RJ-45 Connectors

User Optical GbE LC/LC Connector

Part Numbers
The part numbers for the MDR cables are as follows: 16 x E1/T1 MDR Connector: WA-0276-0, 0.6 meters User 16 x E1/T1 MDR Connector: WA-0277-0, 5 meters WA-0278-0, 10 meters WA-0309-0, 25 meters Optical splitter used for GbE 1+1 systems (see the following section): AO-0038-0 AO-0039-0 AO-0059-0 AO-0060-0

FibeAir IP-10 IDU Installation Guide

1-28

GbE Optical Splitter


The following illustration shows the rear side of the IP-10 protection panel, with the optical splitter.

Optical Splitter

The optical splitter is an LC/LC female adapter.

FibeAir IP-10 IDU Installation Guide

1-29

Appendix D: Accessories
The following tables list the FibeAir IP-10 accessories.

Cables
Part Number WA-0242-1 WA-0246 WA-0259 WA-0275 WA-0276-0 WA-0277-0 WA-0278-0 WA-0284-0 WA-0309-0 Marketing Model X-WSC-E1/T1 IDU-EXT-ALARMS-CBL-2.5m CBL-16E1-CB-120-75 IDU-UC-CBL-2m IP10-CBL-16IO-PROT-0.6m IP10-CBL-16IO-5M IP-10-CBL-16IO-10M IP10-CBL-16IO-XED-0.6m IP-10-CBL-16IO-25M Marketing Description E1/T1 WSC x-ed cable IDU External Alarms open cable 2.5m 16E1 cable MDR/2xDB44 5m to CB-120-75 User channel cable 2m D-type 9 pin male IP-10 16 I/O port protection cable straight 0.6m IP-10 16 I/O port cable open 5M IP-10 16 I/O port cable open 10M IP-10 16 I/O port crossed cable 0.6m IP-10 16 I/O port cable open 25M

Panels
Part Number EN-0254-0 EN-0256-0 EN-0258-0 EN-0259-0 EN-0262-0 Marketing Model IP10-ETH-16E1-PROT-PANEL IP10-ETH-16T1-PROT-PANEL IP10-16E1-PROT-PANEL IP10-16T1-PROT-PANEL IP10-ETH-PROT-PANEL Marketing Description IP-10 Eth + 16E1 protection panel IP-10 Eth + 16T1 protection panel IP-10 16E1 protection panel IP-10 16T1 protection panel IP-10 Eth only protection panel

FibeAir IP-10 IDU Installation Guide

1-30

Optical Splitters
Part Number AO-0038-0 Marketing Model GBE-SPL-SM Marketing Description SM/LC Optical Splitter conn. 1300nm 50/5 MM/LC Optical Splitter 62.5/125 2M MM/LC Optical Splitter 62.5/125 1M MM/LC Optical Splitter 62.5/125 0.6M Item Description 1x2 Single mode Fiber Dual Windows Wideband Couplers, 40nm, LC/LC, 1310nm,1m length, PVC 2.0mm cable (yellow), 50/50 coupling ratio. 1x2 multimode mode Fiber Dual Windows Wideband Couplers, 40nm, LC/LC, 850nm,1m length for each port, PVC 2.0mm cable, 50/50 coupling ratio 1x2 multimode mode Fiber Dual Windows Wideband Couplers, 40nm, LC/LC, 850nm,0.5m length for each port, PVC 2.0mm cable, 50/50 coupling ratio 1x2 multimode mode Fiber Dual Windows Wideband Couplers, 40nm, LC/LC, 850nm,0.3m length for each port, PVC 2.0mm cable, 50/50 coupling ratio

AO-0039-0

GBE-SPL-MM-2M

AO-0059-0

GBE-SPL-MM-1M

AO-0060-0

GBE-SPL-MM-0.6M

Optical Cables
Part Number AO-0033-0 Marketing Model OP-SM-CBL-LC-SCDPLX 15M Marketing Description Duplex Optical Cable LC-SC SM 15M Duplex Optical Cable LC-SC SM 3M Duplex Optical Cable LC-SC SM 1m Duplex Optical Cable LC-SC MM 2M Duplex Optical Cable LC-SC MM 10M Duplex Optical Cable LC-LC MM 0.5M Duplex Optical Cable LC-SC SM 10m Item Description Pairs of Fiber Patchcord Single mode- LC/SC, Length:15M, Duplex PVC 2mm cable, with LC connector type on one end and SC connector on the other end. Pairs of Fiber Patchcord Single mode- LC/SC, Length:3M, Duplex PVC 2mm cable, with LC connector type on one end and SC connector on the other end. DUPLEX LC-SC (Tx TO Tx) SM 9/125 YELLOW COLOR R-9D-1-P, 13MM, 1M DUPLEX FIBER OPTIC MM PATCH CORD WITH LC/UPC-SC/UPC (Tx TO Tx) 62.5/125, ORANGE COLOR, 2M, 3MM O.D. DUPLEX FIBER OPTIC MM PATCH CORD WITH LC/UPC-SC/UPC (Tx TO Tx) 62.5/125, ORANGE COLOR, 10M, 3MM O.D. DUPLEX FIBER OPTIC MM PATCH CORD WITH LC/UPC-LC/UPC (Tx TO Tx) 62.5/125 ORANGE COLOR, 0.5M, 2MM O.D. DUPLEX LC-SC (Tx TO Tx) SM 9/125 YELLOW COLOR, 3MM, 10M

AO-0035-0

OP-SM-CBL-LC-SCDPLX 3M OP-SM-CBL-LC-SCDPLX 1M OP-MM-CBL-LCSC-DPLX 2M OP-MM-CBL-LCSC-DPLX 10M OP-MM-CBL-LCLC-DPLX 0.5M OP-SM-CBL-LC-SCDPLX 10M

AO-0041-0

AO-0044-0

AO-0045-0

AO-0048-0

AO-0055-0

FibeAir IP-10 IDU Installation Guide

1-31

Part Number AO-0057-0

Marketing Model OP-SM-CBL-LC-SCDPLX 5M OP-MM-CBL-LCLC-DPLX 3M OP-MM-CBL-LCLC-DPLX 6M OP-SM-CBL-LC-LCDPLX 3M

Marketing Description Duplex Optical Cable LC-SC SM 5m Duplex Optical Cable LC-LC MM 3M Duplex Optical Cable LC-LC MM 6M Duplex Optical Cable LC-LC SM 3M

Item Description DUPLEX LC-SC (Tx TO Tx) SM 9/125 YELLOW COLOR, 3MM, 5M DUPLEX FIBER OPTIC MM PATCH CORD WITH LC/UPC-LC/UPC (Tx TO Tx) 62.5/125 ORANGE COLOR, 3M, 2MM O.D. DUPLEX FIBER OPTIC MM PATCH CORD WITH LC/UPC-LC/UPC (Tx TO Tx) 62.5/125 ORANGE COLOR, 6M, 2MM O.D. Pairs of Fiber Patchcord Single mode- LC/LC, Length:3M, Duplex PVC 2mm cable, with LC connector type on one end and LC connector on the other end.

AO-0066-0

AO-0067-0

AO-0071-0

Optical Adaptors
Part Number AO-0042-0 Marketing Model OP-SM-LC-LCADPT-SMPLX Marketing Description Adaptor Female/Female LC-LC Simplex Item Description SM SIMPLEX LC-LC SM ADAPTOR

FibeAir IP-10 IDU Installation Guide

1-32

Appendix E: Fan Tray Replacement


Fan Tray Replacment Procedure
If it is necessary to replace the fan tray in the IDU, replace it as follows: 1. Remove the current fan tray by releasing the safety screw and removing the tray. 2. Insert the new fan tray entirely in its place and tighten the safety screw.

FibeAir IP-10 IDU Installation Guide

1-33