25mm GAP FOR Expansion Joint at 24M. C/C 15 Eq. Parts 14 Eq. Parts 14 Eq. Parts

This drawing shows plans and elevations for a compound wall for Delta Electronics Ltd. in SIPCOT, Sriperumbudur. The wall is 230mm thick brick construction with RCC columns spaced at 6000mm centers. Notes indicate the drawing is the property of Sijcon Architects and must be checked against architectural drawings. Dimensions are in mm unless noted otherwise and the location can be found on site plan drawing DEC-AR-101. The drawing was issued for tender purposes and is stamped as for reference only.

Uploaded by

dox4use
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
258 views1 page

25mm GAP FOR Expansion Joint at 24M. C/C 15 Eq. Parts 14 Eq. Parts 14 Eq. Parts

This drawing shows plans and elevations for a compound wall for Delta Electronics Ltd. in SIPCOT, Sriperumbudur. The wall is 230mm thick brick construction with RCC columns spaced at 6000mm centers. Notes indicate the drawing is the property of Sijcon Architects and must be checked against architectural drawings. Dimensions are in mm unless noted otherwise and the location can be found on site plan drawing DEC-AR-101. The drawing was issued for tender purposes and is stamped as for reference only.

Uploaded by

dox4use
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

File Name:-X:\Drawings 2011\Delta Electronics Chennai Tender\DEC-TEN-110.

Dwg

GENERAL NOTES :THIS DRAWING IS THE PROPERTY OF SIJCON AND NOT TO BE COPIED OR USED WITHOUT OUR PERMISSION 1. ALL DIMENSIONS ARE TO BE CHECKED AND CO-RELATED WITH THE ARCHITECTURAL DRAWINGS AND ANY AMBIGUITY SHALL BE IMMEDIATELY BROUGHT TO THE NOTICE OF THE ARCHITECT BEFORE COMMENCEMENT OF THE WORK. 2. ALL DRAWINGS ARE TO BE READ AND NOT TO BE MEASURED. 3. ALL DIMENSIONS ARE IN MM UNLESS MENTIONED OTHERWISE.

NOTES :1. FOR LOCATION REFER SITE PLAN DRG. NO. : DEC-AR-101.

REVISIONS :NO. DATE REMARKS

25mm GAP FOR EXPANSION JOINT @ 24M. C/C 14 EQ. PARTS

25MM SQUARE BAR

35x25MM TISCO TUBE

15 EQ. PARTS

14 EQ. PARTS

300x300mm R.C.C. COLUMN @ 6000mm C/C

200

2100

1500

PRINTS ISSUED :NOS. DATE NOS. DATE e-mail Client 04/08/11

200 50

600

50x75MM TISCO TUBE TO BE GROUTED IN COPING SAND FACED PLASTER 230mm THK.WALL (TYP.)

NOS. DATE

FOR REFERENCE FOR TENDER FOR ESTIMATION

FOR SUPPLIERS FOR APPROVAL FOR EXECUTION

COMPOUND WALL

2000

2000 6000

2000

PART ELEVATION

OF F

ICE

BL

DG

MA

IN

PL A

NT

25mm GAP FOR EXPANSION JOINT @ 24M. C/C

230 THK. BRICK WALL 300x300mm R.C.C. COLUMN @ 6000mm C/C


W

N
E
S

KEY PLAN

DELTA ELECTRONICS LTD.


AT:SIPCOT (SRIPERUMBUDUR)

6000

For Tender Only

PART PLAN

SIJCON ARCHITECTS CONSULTING ENGINEERS


25, Raopura Society, B/h. Memnagar Fire Station, Navrangpura, Ahmedabad - 380 009. Gujarat, INDIA Phone : +91-79-27911205, 27911017 Fax : 27910926 E-mail : [email protected] Website : www.sijcon.com

COMPOUND WALL
DRG. NO. : TITLE : SCALE : DEALT :

DEC-TEN-110

PLAN & ELEVATION N.T.S. Rajeev


SHEET :

1 0F 1

DRFT. SIGN : CHK. BY : DATE : REV. NO.

16/05/2011
R0