Lap Joint Between Plate: Design Strength of Plate (TDN) 233.798 KN An 792

The document provides information to design the lap joint between two steel plates under eccentric loading and tension conditions. It includes the plate dimensions, bolt properties, formulas to calculate the design strength of the plate and bolts in shear, bearing and tension. It then calculates the direct force, bending moment and tensile force in the extreme bolt due to eccentric loading. The calculated forces are compared to the design strength of the bolts to check if the design is safe.

Uploaded by

brintopv
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
42 views15 pages

Lap Joint Between Plate: Design Strength of Plate (TDN) 233.798 KN An 792

The document provides information to design the lap joint between two steel plates under eccentric loading and tension conditions. It includes the plate dimensions, bolt properties, formulas to calculate the design strength of the plate and bolts in shear, bearing and tension. It then calculates the direct force, bending moment and tensile force in the extreme bolt due to eccentric loading. The calculated forces are compared to the design strength of the bolts to check if the design is safe.

Uploaded by

brintopv
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 15

LAP JOINT BETWEEN PLATE

Width of Plate (b)=

Thickness of Plate (t)=


12
24
pitch (p)

660

2.00

Number of bolt perpanticular to force in one line(N)=


Total number of bolt(n)=

edge distance (e)

55

50

Diameter of Hole (do)


Diameter of bolt (d)

Ultimate stress of Material (fu)=


Ultimate stress of bolt (fub)=

22.0
20.0

number of shear plane in shank (ns)

0.0

Design strength of plate

0.9 * An * fu
Tdn = ------------------------1.25
An = Net effective area
fu
t
b
N

[ b N d0 ] * t

= Ultimate tensile stress of material or plate in N/mm2


= Thickness of plate
= width of plates.
=Number of bolt perpanticular to force, do= Hole dia

Design Strength of Plate (Tdn)= 233.798 KN

Design Strength of bolts


a

shear capacity of bearing bolts in a joint

An = 792

mm2

410.0
400.0

N/mm2
N/mm2

Vdsb =

Fub *
-----------------------------((3)^(1/2))*1.25

{ (n*Anb)+(ns*Asb)}
Anb=

Asb=

Design strength in shear (Vdsb)= 1,085.99 KN


b

0.78* 3.14*d^2
--------------------------4
3.14 * d * d
---------------------------4

Anb = 244.92

design strength in bearing


Vnpb= 2.5 * Kb * d * t * fu

Design strength in bearing (Vnpb)= 401.472 KN

Design strength of joint =

kb = .51

233.7984 KN

mm2

Asb = 314.00

mm2

eccentric loading

ECCENTRIC LOADING

Load in KN

300

Thickness of Plate (t)=


350
12
pitch (p)

7.60

Distance from centre of beam to load position


Total number of bolt in one raw (n)=

edge distance (e)

55

Diameter of Hole (do)


Diameter of bolt (d)

Ultimate stress of Material (fu)=


Ultimate stress of bolt (fub)=
24

22.0
20.0

Total number of bolt=

50
Number of bolt as per calculation

a
b

N/mm2
2
N/mm

410.0
400.0

70
275

12
it should be even
r=

Design Strength of bolts


a

shear capacity of bearing bolts in a joint


Vdsb =

Fub *
-----------------------------((3)^(1/2))*1.25

{ (n*Anb)+(ns*Asb)}
Anb=

Asb=

Design strength in shear (Vdsb)= 45.27


b

KN

0.78* 3.14*d^2
--------------------------4
3.14 * d * d
---------------------------4

Anb = 245.04

mm2

design strength in bearing


Vnpb= 2.5 * Kb * d * t * fu

Design strength in bearing (Vnpb)= 63.5664 KN

kb = .51

Page 3

283.77

eccentric loading

ECCENTRIC LOADING
DIRECT FORCE (F1) = 12500

BENDING FORCE (F2) = 35786.5

N
r=
Sum of (r^2)=
COS O=

283.77
832600.0
0.24668

RESULTANT FORCE ON EXTREME BOLT =

40.7

KN

4148.8 Kg

DESIGN CAPACITY OF BOLT =

45.3

KN

4617.7 Kg

Page 4

eccentric loading

DESIGN IS SAFE

Page 5

TENSION

TENSION LOADING IN BOLT

Diameter of bolt (d)

Ultimate stress of bolt (fub)=


Yield stress of bolt (fyb)=

8.0

Design Strength of bolts


a

TENSION CAPACITY
Tnb =
=

0.9 * Fub * Anb


-----------------------------1.25
2258
N

or

Tnb =

which one is smaller

Fyb * Asb
-----------------------------1.10
2,193.60
N

Anb=

Asb=

Design strength = 2.19

KN

0.78* 3.14*d^2
--------------------------- =
4
3.14 * d * d
---------------------------- =
4

223.24 Kg

Page 6

39.21
50.27

80.0
48.0

N/mm2
N/mm2

TENSION

Page 7

TENSION

Page 8

TENSION

bolt

Page 9

TENSION

Page 10

TENSION

Page 11

ECCENTRIC LOADING +TENSION

ECCENTRIC LOADING

Load in KN

600

Thickness of Plate (t)=


300
14

9.00

Distance from centre of beam to load position


Total number of bolt(n)=

edge distance (e)

50

50

Pitch(p)

Diameter of Hole (do)


Diameter of bolt (d)

bolt

22.0
20.0

60
55
it is multiple of 10

Ultimate stress of Material (fu)=


Ultimate stress of bolt (fub)=
Yield stress of bolt (fyb)=
Number of bolt as per calculation

N/mm2
N/mm2
N/mm2

410.0
400.0
240.0
14

r=

Design Strength of bolts


a

shear capacity of bearing bolts in a joint


Vdsb =

Fub *
-----------------------------((3)^(1/2))*1.25

{ (n*Anb)+(ns*Asb)}
Anb=

Asb=

Design strength in shear (Vdsb)= 45.27


b

KN

0.78* 3.14*d^2
--------------------------4
3.14 * d * d
---------------------------4

Anb = 245.04

design strength in bearing


Vnpb= 2.5 * Kb * d * t * fu

Page 12

mm2

0.00

ECCENTRIC LOADING +TENSION

Design strength in bearing (Vnpb)= 97.416


b

KN

kb = .66

Design tension capacity

Tnb =

0.9 * Fub * Anb


-----------------------------1.25
70.57

or

Fyb * Asb
-----------------------------1.10

Tnb =

KN

68.55

Design strength in tension (tdb)= 68.55

KN

Design strength of one bolt= 45.27

KN

Anb=

0.78* 3.14*d^2
--------------------------- =
4

Asb=

3.14 * d * d
---------------------------- =
4

KN

245.04

mm2

314.2

mm2

ECCENTRIC LOADING
h=
h/7=
y =

M
M'= ..................................................................
y
2h
1 '+'
................... ..................
y 2
21

M'=
y
Tb

M' * y
Tensile force in extreme bolt due to bending moment Tb= ................................................

Tensile force in extreme bolt due to bending moment=

48.8307 KN

Page 13

830.0
118.57
4577.16
2260666.14
155166082
711.43
48830.65

mm2
mm2
N-mm
N

ECCENTRIC LOADING +TENSION

DIRECT FORCE (F1) =


2
21428.57
checking= ...................
45270

2
48830.65
........................
68550

21428.57

0.7315

Design Safe