0% found this document useful (0 votes)
19 views1 page

Certificate of Visual Examination and Mpi

This document is a certificate of visual examination and magnetic particle inspection (MPI) for elevator bails with identification numbers JRB5 A and JRB5 B. The inspection was conducted on July 8, 2011 by Ezekiel Fwangshak, a level II MT, PT, and UT qualified examiner. The inspection followed API RP 7K specifications using wet visible and black magnetic ink contrast methods and found no defects in the load bearing areas, declaring the bails fit for use.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
19 views1 page

Certificate of Visual Examination and Mpi

This document is a certificate of visual examination and magnetic particle inspection (MPI) for elevator bails with identification numbers JRB5 A and JRB5 B. The inspection was conducted on July 8, 2011 by Ezekiel Fwangshak, a level II MT, PT, and UT qualified examiner. The inspection followed API RP 7K specifications using wet visible and black magnetic ink contrast methods and found no defects in the load bearing areas, declaring the bails fit for use.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

JCI

JC International Limited

RC 413243

PPI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O Box. 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. Date of Examination Examiner Qualifications

46671 Identification Number

07/08/2011

EZEKIEL FWANGSHAK

SNT LEVEL II MT, PT & UT

Description of Equipment: ELEVATOR BAIL

S/N: JRB5 A JRB5 B

METHOD: All the accessible critical areas were cleaned to bare metal and inspected based on the specification and the test procedure stipulated below.

LOCATION: RIG FLOOR


SPECIFICATION : API RP 7K MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Load Bearing Areas RESULTS: No defect as at the time of inspection fit for use. Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

Jack Ryan

We hereby certify that on 07/08/2011 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: EZEKIEL FWANGSHAK