DWG NO
A4
Item Devices PID 0425 20AA-1
381A6409
Item TG 0983
SH
16
REV
Designation Solenoid valve for VA18-1 control. Characteristics: Normal : 1 to 3 open ; 2 closed. 35 W | 125 VDC Solenoid valve for VA22-1 control. Characteristics: Normal : 1 to 3 open ; 2 closed. 35 W | 125 VDC Compressor Bleed Solenoid Valve Characteristics: Normal : B to C Open ; A closed Fuel pump clutch solenoid Characteristics: Normal : NO 160W(max) | 100-125VDC Gas fuel stop valve solenoid Characteristics: Normal: NO Liquid fuel stop gas solenoid Characteristics: Normal : NO purge fuel liquid solenoid valve Characteristics : Normal : port OH4 closed Solenoid valve for VA13-1 control. Characteristics: Normal : 1 to 3 open ; 2 closed. 35 W | 125 VDC Settings: A Needle-Valve is installed upstream of 20PG-1 in order to adjust VA13-1 Time Opening at 30 seconds. Solenoid valve for VA13-2 control. Characteristics: Normal : 1 to 3 open ; 2 closed. 35 W | 125 VDC Settings: A Needle-Valve is installed upstream of 20PG-1 in order to adjust VA13-1 Time Opening at 30 seconds. Solenoid valve for VA19-1 control. Characteristics: Normal : 1 to 3 open ; 2 closed. 35 W | 125 VDC Torque Converter Fill / Drain Solenoid Valve Characteristics: Normal : NC Turbine compressor IGV solenoid valve Characteristics: Normal : NO Motor Valve Off-Line Compressor Water Wash Characteristics: 92 W | 115 VAC | 50/60 Hz | 1 PH | Fail safe to close Motor Valve Turbine Water Wash Characteristics: 230 W | 115 VAC | 50/60 Hz | 1 PH | Fail safe to close Motor Valve On-Line Compressor Water Wash Characteristics: 92 W | 115 VAC | 50/60 Hz | 1 PH | Fail safe to close Fuel Gaz Vet solenoid Valve Characteristics: Normal : NO 125 VDC Vent Solenoid Valve of inter-valve cavity VA13-1 and VA13-2. Characteristics: Normal : NO 125 W | 125 VDC Solenod valve for Water injection transfer valve VC5-1 Characteristics : Normal : NC Solenod valve for Water Injection Control valve VC4-1 Characteristics : Normal : NO Motor space heater for 88AB-1 Characteristics: 50 W | 230 VAC | 50 Hz | 1 PH | Anti-condensation heater for motor 88BT-1 Characteristics: 0,05 kW | 230 VAC | 50 Hz | 1 PH | Anti-condensation heater for motor 88BT-2 Characteristics: 0,05 kW | 230 VAC | 50 Hz | 1 PH | Cranking Motor Space Heater Characteristics: 180 W | 230 VAC | 50 Hz | 1 PH | Cranking Motor Space Heater Characteristics: 180 W | 230 VAC | 50 Hz | 1 PH | Cranking Motor Space Heater Characteristics: 180 W | 230 VAC | 50 Hz | 1 PH | Accessory compartment heater Characteristics: 18 kW | 230 VAC | 50 Hz | 1 PH | GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO
0425 20AB-1 0417 20CB-1 0424 20CF-1 0418 20FG-1 0418 20FL-1 0424 20PF-100
0477 20PG-1
0918
0477 20PG-2
0918
0442 20TW-2
0983
0442 20TW-3
0953
0422 20VG-1
0911
0477 20VG-2 0462 20WN-2 0462 20WN-4 0425 23AB-1 0436 23BT-1 0436 23BT-2 0421 23CR-1 0421 23CR-2 0421 23CR-3 0436 23HA
0918 A035 A035 1047 Encl. Encl. 0603 0603 0603 1137
g
DRAWN
381A6409
A4
SECTION 01E
SCALE SHEET
16
SIZE
DWG NO
A4
Item Devices PID 0434 23HQ-1 0436 23HT 0416 23QT-1 0416 23QT-2 0421 23TG-1 0417 23TK-1 0417 23TK-2 0436 23VG-1 0436 23VG-2 0462 23WN-1 0421 26CR-1 0421 26CR-2 0421 26CR-3 0436 26HA
381A6409
Item TG 0628 Encl. 0938 0938 0603 1233 1233 1643 1643 A035 0603 0603 0603 1137
SH
17
REV
Designation Heater hydraulic oil pump motor Characteristics: 0,05 kW | 230 VAC | 50 Hz | 1 PH | Acoustic TG enclosure Heater Characteristics: 18 kW | 230 VAC | 50 Hz | 1 PH | Immersion heater Lube Oil Tank Characteristics: 10,2 kW | 400 VAC | 50 Hz | 3 PH | Immersion heater Lube Oil Tank Characteristics: 10,2 kW | 400 VAC | 50 Hz | 3 PH | Turning Gear Motor Space Heater Characteristics: - kW | 230 VAC | 50 Hz | 1 PH | Anti-condensation heater for motor 88TK-2 Characteristics: - kW | 230 VAC | 50 Hz | 1 PH | Anti-condensation heater for motor 88TK-2 Characteristics: - kW | 230 VAC | 50 Hz | 1 PH | Motor space heater for 88VG-1 Characteristics: 0,05 kW | 230 VAC | 50 Hz | 1 PH | Motor space heater for 88VG-2 Characteristics: 0,05 kW | 230 VAC | 50 Hz | 1 PH | Anti-condensation heater for motor 88WN-1 Characteristics: 0,05 kW | 230 VAC | 50 Hz | 1 PH | Stator Winding High Temperature Sensor - Ph1 Characteristics: Non linear RTD type - 2 stable states Stator Winding High Temperature Sensor - Ph2 Characteristics: Non linear RTD type - 2 stable states Stator Winding High Temperature Sensor - Ph3 Characteristics: Non linear RTD type - 2 stable states Thermostat, lower temperature in accessory compartment Characteristics: Normal : NO measure range : 2 to 50C (35,6 to 122F) Thermostat, low temperature in acoustic enclosure Characteristics: Normal : NO measure range : 2 to 50C (35,6 to 122F) Flame detector Flame detector Flame detector Flame detector GT enclosure ventilation damper limit switch Characteristics: Normal : NO Settings: damper open : limit switch activated and contact closed GT enclosure ventilation damper limit switch Characteristics: Normal : NO Settings: damper open : limit switch activated and contact closed 11 stage compressor Bleed Valve Limit Switch Characteristics: Normal : NO Settings: Valve open : limit switch activated, contact closed 11 stage compressor Bleed Valve Limit Switch Characteristics: Normal : NO Settings: Valve open : limit switch activated, contact closed 11 stage compressor Bleed Valve Limit Switch Characteristics: Normal : NO Settings: Valve open : limit switch activated, contact closed 11 stage compressor Bleed Valve Limit Switch Characteristics: Normal : NO Settings: Valve open : limit switch activated, contact closed Liquid fuel stop valve limit switch (bc) Characteristics: Normal: NO Settings: Valve closed : switch actuated, contact closed Liquid fuel stop valve limit switch Characteristics: Normal: NO Settings: Valve opened : switch actuated, contact closed purge fuel liquid valve limit switch VP-1 purge fuel liquid valve limit switch VP-2 VA13-1 Close Position Limit Switch. Characteristics: Normal: NO Settings: Valve closed : switch actuated, contact closed. GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO
0436 26HT 0415 0415 0415 0415 28FD-10 28FD-11 28FD-4 28FD-5
0436 33BT-1
0436 33BT-2
Encl.
0417 33CB-1
1022
0417 33CB-2
1022
0417 33CB-3
1022
0417 33CB-4
1022
0424 33FL-1
0511
g
DRAWN
381A6409
A4
SECTION 01E
SCALE SHEET
17
SIZE
DWG NO
A4
Item Devices PID 0477 33PG-2
381A6409
Item TG 0918
SH
18
REV
Designation VA13-1 Open Position Limit Switch. Characteristics: Normal: NO Settings: Valve open : switch actuated, contact closed VA13-2 Close Position Limit Switch. Characteristics: Normal: NO Settings: Valve closed : switch actuated, contact closed. VA13-2 Open Position Limit Switch. Characteristics: Normal: NO Settings: Valve open : switch actuated, contact closed Torque Converter Solenoid Valve Limit Switch Characteristics: Normal : NO Settings: Switch activated with 20TU-1 de energized - Contact closed Torque Converter Low Torque Limit Switch Settings: Setup at 2 tr (range 0-31 tr) Torque Converter High Torque Limit Switch Settings: Setup at 28 tr (range 0-31 tr) Load compartment ventilation damper limit switch Characteristics: Normal : NO Settings: damper open : limit switch activated and contact closed Limit Switch on Solenoid Valve 20VG-1 Characteristics: See specifications Settings: Valve open :limit switch activated and contact closed Load compartment ventilation damper limit switch Characteristics: Normal : NO Settings: damper open : limit switch activated and contact closed VC4-1 control valve limit switch Characteristics: Normal: NO Settings: Switch actuated and contact closed when control valve full open VC5-1 transfer valve limit switch Characteristics: Normal: NO Settings: Switch actuated and contact closed when control valve full open VC4-1 control valve limit switch Characteristics: Normal: NO Settings: Switch actuated and contact closed when control valve full closed VC5-1 transfer valve limit switch Characteristics: Normal: NO Settings: Switch actuated and contact closed when control valve full closed Vibration Sensor Characteristics: For 25,4 mm/s (1 in/s), 150 4,5 mV peak Vibration Sensor Characteristics: For 25,4 mm/s (1 in/s), 150 4,5 mV peak Vibration Sensor Characteristics: For 25,4 mm/s (1 in/s), 150 4,5 mV peak Vibration Sensor Characteristics: For 25,4 mm/s (1 in/s), 150 4,5 mV peak Vibration Sensor Characteristics: For 25,4 mm/s (1 in/s), 150 4,5 mV peak Vibration Sensor Settings: -10,5 0,5 VDC Vibration Sensor Settings: -10,5 0,5 VDC Vibration Sensor Settings: -10,5 0,5 VDC Vibration Sensor Settings: -10,5 0,5 VDC Break glass unit accessory compartment Characteristics: Normal : NO Break glass unit GT compartment Characteristics: Normal : NO Break glass unit accessory compartment Characteristics: Normal : NO Break glass unit GT compartment Characteristics: Normal : NO Break glass unit load compartment Characteristics: Normal : NO GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO
0477 33PG-3
0918
0477 33PG-4
0918
0422 33VG-11
0911
0436 33VG-2
Encl.
0462 33WN-1
A035
0462 33WN-3
A035
0462 33WN-6
A035
0462 33WN-7 0415 39V-1A 0415 39V-1B 0415 39V-2A 0415 39V-3A 0415 39V-3B 0415 39VS-11 0415 39VS-12 0415 39VS-31 0415 39VS-32 0426 43CP-1 0426 43CP-2 0426 43CP-3 0426 43CP-4 0426 43CP-5
A035 1218 1218 1218 1218 1218 0235 0235 1160 1160 Encl. Encl. Encl. Encl. Encl.
g
DRAWN
381A6409
A4
SECTION 01E
SCALE SHEET
18
SIZE
DWG NO
A4
Item PID 0424 0442 0442 Devices 43FUOP 43TW-1/PB 43TW-2/PB
381A6409
Item TG 1103 1105 1105 1104 1104 1104 1104 1103 1103 1154 1154 1154 1154 1160 1160 1160 1160 Encl. Encl. Encl. Encl. Encl. Encl. Encl. Encl. Encl. Encl. Encl. Encl. 1104 1104
SH
19
REV
Designation valve VP-1 and VP-2 push button Off-Line Water Wash Push button Turbine Water Wash Push button Thermostatic fire detector Accessory compartment Characteristics: Normal : NO Closed : 163 14C (325 25F) Thermostatic fire detector Accessory compartment Characteristics: Normal : NO Closed : 163 14C (325 25F) Thermostatic fire detector Accessory compartment Characteristics: Normal : NO Closed : 163 14C (325 25F) Thermostatic fire detector Accessory compartment Characteristics: Normal : NO Closed : 163 14C (325 25F) Thermostatic fire detector Turbine compartment Characteristics: Normal : NO Closed : 316 14C (600 25F) Thermostatic fire detector Turbine compartment Characteristics: Normal : NO Closed : 316 14C (600 25F) Thermostatic fire detector Turbine compartment Characteristics: Normal : NO Closed : 316 14C (600 25F) Thermostatic fire detector Turbine compartment Characteristics: Normal : NO Closed : 316 14C (600 25F) Thermostatic fire detector Turbine compartment Characteristics: Normal : NO Closed : 316 14C (600 25F) Thermostatic fire detector Turbine compartment Characteristics: Normal : NO Closed : 316 14C (600 25F) Thermostatic fire detector Load compartment Characteristics: Normal : NO Closed : 385 14C (725 25F) Thermostatic fire detector Load compartment Characteristics: Normal : NO Closed : 385 14C (725 25F) Thermostatic fire detector Load compartment Characteristics: Normal : NO Closed : 316 14C (600 25F) Thermostatic fire detector Load compartment Characteristics: Normal : NO Closed : 316 14C (600 25F) Gas detector Gas Auxiliary compartment Characteristics: Range : 0 - 20% LEL Gas detector in Auxiliary Compartment Characteristics: Range : 0 - 20% LEL Gas detector Gas in Auxiliary Compartment. Characteristics: Range : 0 - 20% LEL Gas detector Gas in Gas cabinet Module. Characteristics: Range : 0 - 20% LEL Gas detector Gas in Gas cabinet Module. Characteristics: Range : 0 - 20% LEL Gas detector Gas in Gas cabinet Module. Characteristics: Range : 0 - 20% LEL Gas detector Turbine Compartment Characteristics: Range : 0 - 20% LEL Gas detector Turbine Compartment Characteristics: Range : 0 - 20% LEL Gas detector Turbine Compartment Characteristics: Range : 0 - 20% LEL Gas detector Turbine Compartment ventilation duct Characteristics: Range : 0 - 20% LEL Gas detector Turbine Compartment ventilation duct Characteristics: Range : 0 - 20% LEL Gas detector Turbine Compartment ventilation duct Characteristics: Range : 0 - 20% LEL Emergency Stop Button accessory compartment Characteristics: Normal : NC Emergency Stop Button accessory compartment Characteristics: Normal : NC Liquid fuel pressure upstream of stop valve Characteristics: NORMAL: NO Settings: DEC opened = 35 1 psig INC closed = 40 2 psig
0426 45FA-1A 0426 45FA-1B 0426 45FA-2A 0426 45FA-2B 0426 45FT-1A 0426 45FT-1B 0426 45FT-2A 0426 45FT-2B 0426 45FT-3A 0426 45FT-3B 0426 45FT-8A 0426 45FT-8B 0426 45FT-9A 0426 45FT-9B 0474 45HA-1 0474 45HA-2 0474 45HA-3 0474 45HA-4 0474 45HA-5 0474 45HA-6 0474 45HT-1 0474 45HT-2 0474 45HT-3 0474 45HT-4 0474 45HT-5 0474 45HT-6 0426 5E-1 0426 5E-2
0424 63FL-2
0926
SIZE
CAGE CODE
DWG NO
g
DRAWN
381A6409
A4
SECTION 01E
SCALE SHEET
19
SIZE
DWG NO
A4
Item Devices PID 0434 63HF-1
381A6409
Item TG 0926
SH
20
REV
Designation Hyd.filter diff. press. alarm Characteristics: Normal : NC Settings: Inc open at 4,13 0,2 bar (60 3 psi) Dec close at 2,75 1,03 bar (40 15 psi) Hydraulic Trip Oil Pressure sw gas stop valve Characteristics: Normal: NO Settings: Dec. Open : 1,40 0,07 bar (20 1 psi) (For Information Inc. Close : 1,65 0,14 bar (24 2 psi)) Hydraulic Trip Oil Pressure sw gas stop valve Characteristics: Normal: NO Settings: Dec. Open : 1,40 0,07 bar (20 1 psi) (For Information Inc. Close : 1,65 0,14 bar (24 2 psi)) Hydraulic Trip Oil Pressure sw gas stop valve Characteristics: Normal : NO Settings: Dec. Open : 1,40 0,07 bar (20 1 psig) (For Information Inc. Close : 1,65 0,14 bar (24 2 psi)) Hydraulic Trip Oil Pressure - Liquid Fuel System Characteristics: Normal : NO Settings: (For Information Inc. Close : 1,65 0,14 bar (24 2 psi)) Dec. Open : 1,40 0,07 bar (20 1 psi) Hydraulic Trip Oil Pressure - Liquid Fuel System Characteristics: Normal : NO Settings: (For Information Inc. Close : 1,65 0,14 bar (24 2 psi)) Dec. Open : 1,40 0,07 bar (20 1 psi) Hydraulic Trip Oil Pressure - Liquid Fuel System Characteristics: Normal : NO Settings: (For Information Inc. Close : 1,65 0,14 bar (24 2 psi)) Dec. Open : 1,40 0,07 bar (20 1 psi) Low hydraulic supply press. aux hydl. pump start Characteristics: Normal : NO Settings: Inc closed at 100 3,1 bar (1450 45 psi ) Dec open at 93 1,7 bar (1350 25 psi) Fuel filter differential pressure alarm Characteristics: NORMAL: NC Settings: INC opened = 15 1 psi Pressure switch on VA13-1 & VA13-2 intervalves space. Characteristics: Normal: NC Settings: Increase open at 3,10 0,13 bar (45 2 psi) For information, decrease close at 2,75 0,13 bar (45 2 psi) Pressure switch on liquid fuel purge air. Characteristics: Normal: NO Settings: Increase close at 7 0,25 bar (101 4 psi) For information decrease open at 5,6 0,25 bar (81 4 psi). Low Lube Oil Pressure Alarm Characteristics: Normal : NO Settings: Dec. Open : 2,8 0,07 bar (40,6 1 psig) (For Information : Inc. Close : 3,1 0,14 bar ( 45 2 psig)) Differential pressure switch Main Lube Oil Filter Characteristics: Normal : NC Settings: Inc. Open : 1,03 0,068 bar (15 0,1 psig) (For Information : Dec. Close : 0,9 0,2 bar (13 3 psig)) Torque converter filter differencial pressure Characteristics: Normal : NC Settings: Inc. Open : 1,5 0,2 bar (21,75 3 psi) Low Lube Oil Pressure generator side Characteristics: Normal : NO Settings: Dec. Open : 0,55 0,021 bar (8 0,3 psig) (For Information : Inc. Close :0,62 0,035 bar (9 0,5 psig)) Oil mist eliminator filter high pressure drop alarm Characteristics: Normal : NC Settings: Inc. open : 80 3 mbar (1,16 0,04 psi) Turbine shell and exhaust frame blower discharge pressure switch Characteristics: Normal : NO Settings: Closed above 15 3 inch H2O
0418 63HG-1
0926
0418 63HG-2
0926
0418 63HG-3
0926
0418 63HL-1
0926
0418 63HL-2
0926
0418 63HL-3
0926
0434 63HQ-1
0926
0424 63LF-3
0992
0477 63PG-1
0918
0477 63PL-21
0918T
0416 63QA-2
0926
0416 63QQ-1
0926
0416 63QQ-8
0916
0416 63QT-2A
ALT.
0416 63QV-1
0926
0417 63TK-1
A053
SIZE
CAGE CODE
DWG NO
g
DRAWN
381A6409
A4
SECTION 01E
SCALE SHEET
20
SIZE
DWG NO
A4
Item Devices PID 0417 63TK-2
381A6409
Item TG A053
SH
21
REV
Designation Turbine shell and exhaust frame blower discharge pressure switch Characteristics: Normal : NO Settings: Closed above 15 3 inch H2O Gas cabinet ventilation pressure switch Characteristics: Normal : NO Settings: increase close at 25 3 mm CE Liquid fuel pump (by pass valve) servo valve Gas control valve servo valve High level lube oil tank Characteristics: Normal : NC Settings: Incr. open on high level. See lube oil schematic MLItem 416 for setting Low level lube oil tank Characteristics: Normal : NO Settings: Decr. open on low level. See lube oil schematic MLItem 416 for setting Flow divider magnetic pickup Settings: Gap : 0,20 0,02 mm (0,0078 0,00078 in) Flow divider magnetic pickup Settings: Gap : 0,015 0,002 in Flow divider magnetic pickup Settings: Gap : 0,015 0,002 in Speed Sensor Settings: Air-gap : 1,27 0,127 mm (0,05 0,005 inch) Speed Sensor Settings: Air-gap : 1,27 0,127 mm (0,05 0,005 inch) Speed Sensor Settings: Air-gap : 1,27 0,127 mm (0,05 0,005 inch) Speed Sensor Settings: Air-gap : 1,27 0,127 mm (0,05 0,005 inch) Speed Sensor Settings: Air-gap : 1,27 0,127 mm (0,05 0,005 inch) Speed Sensor Settings: Air-gap : 1,27 0,127 mm (0,05 0,005 inch) Vibration Sensor Settings: -10,5 0,5 VDC Water injection common circuit flow pick-up Settings: 0 0,05 V = 0 GPM 10 0,05 V = 130 GPM Atomizing air booster motor Characteristics: 15 kW | 2925 rpm | 400 VAC | 50 Hz | 3 PH | Cooling air fan motor - Acoustic enclosure Characteristics: 15 kW | 1460 rpm | 400 VAC | 50 Hz | 3 PH | Cooling air fan motor - Acoustic enclosure Characteristics: 15 kW | 1460 rpm | 400 VAC | 50 Hz | 3 PH | Electrical Cranking Motor Characteristics: 1000 kW | 2975 rpm | 6,6 kV | 50 Hz | 3 PH | Flow divider starting motor Characteristics: 0,37 kW | 1400 rpm | 400 VAC | 50 Hz | 3 PH | Air Fan of Accessory compartment heater (auxiliary) hydraulic supply pump motor Characteristics: 15 kW | 2925 rpm | 400 VAC | 50 Hz | 3 PH | Air Fan of Acoustic TG enclosure Heater Auxiliary Lube oil pump motor Characteristics: 90 kW | 3000 rpm | 400 | 50 Hz | 3 PH | Emergency Lube Oil Pump Motor Characteristics: 7,5 kW | 1750 rpm | 125 V | - Hz | DC | Lube Oil Mist Eliminator Motor Characteristics: 7,5 kW | 3000 rpm | 400 VAC | 50 Hz | 3 PH | Turning Gear Electrical Motor Characteristics: 30 kW | 725 rpm | 400 VAC | 50 Hz | 3 PH | Settings: Not applicable Turbine Exhaust Frame Cooling Fan Vent Motor Characteristics: 45 kW | 2900 rpm | 400 VAC | 50 Hz | 3 PH | Turbine Exhaust Frame Cooling Fan Vent Motor Characteristics: 45 kW | 2900 rpm | 400 VAC | 50 Hz | 3 PH | DWG NO
0436 63VL 0424 65FP 0422 65GC 0416 71QH-1 0533 0541 1038
0416 71QL-1 0424 77FD-1 0424 77FD-2 0424 77FD-3 0415 77HT-1 0415 77HT-2 0415 77HT-3 0415 77NH-1 0415 77NH-2 0415 77NH-3 0415 77RP-11 0462 77WN-1T3 0425 88AB-1 0436 88BT-1 0436 88BT-2 0421 88CR-1 0424 88FM 0436 88HA 0434 88HQ-1 0436 88HT 0416 88QA-1 0416 88QE-1 0416 88QV-1 0421 88TG-1 0417 88TK-1 0417 88TK-2
1038 0992 0992 0992 0546 0546 0546 0546 0546 0546 0235 A035 1047 Encl. Encl. 0603 0613 1137 0628 Encl. 1006 1007 A098 0538 1233 1233
SIZE
CAGE CODE
g
DRAWN
381A6409
A4
SECTION 01E
SCALE SHEET
21
SIZE
DWG NO
A4
Item Devices PID 0421 88TM-1 0436 88VG-1 0436 88VG-2 0436 88VL-1 0436 88VL-2 0462 88WN-1 0422 0469 0462 0415 0415 90SR-1 90TV-1 90WN-1 95SP-13 95SP-14
381A6409
Item TG 0605 Encl. Encl. 1605 1605 A035 0541 0540 A035 1214 1214 1213 1213 0926 0559 0559 0559 0557 0559 0557
SH
22
REV
Designation Torque adjuster drive motor Characteristics: 1,5 kW | 3000 rpm | 400 VAC | 50 Hz | 3 PH | Cooling air fan motor Load compartment. Characteristics: 7,5 kW | 1450 rpm | 400 VAC | 50 Hz | 3 PH | Cooling air fan motor Load compartment. Characteristics: 7,5 kW | 1450 rpm | 400 VAC | 50 Hz | 3 PH | Cooling air fan motor - Gas compt. Characteristics: 3 kW | - rpm | 400 VAC | 50 Hz | 3 PH | Cooling air fan motor - Gas compt. Characteristics: 3 kW | - rpm | 400 VAC | 50 Hz | 3 PH | Water injection syst. Pump motor Characteristics: 90 kW | 3000 rpm | 400 VAC | 50 Hz | 3 PH | Speed ratio/stop valve servo valve Inlet Guide Vane Servovalve Servovalve for VC5-1 control valve Spark plug Spark plug Ignition transformer for 95SP-13 Characteristics: 345 VA | 230 VAC | 15 kV | 0,35 kW Ignition transformer for 95SP-14 Characteristics: 345 VA | 230 VAC | 15 kV | 0,35 kW Atomizing air main compressor differential pressure transmitter Settings: 4 0.05 mA for 0 bar 20 0.05 mA for 6 bar (87 psi) Pressure transmitter Settings: 4 mA 0,02 mA for 0,800 bar (23,6 in of Hg), 20 mA 0,10 mA for 1,200 bar (35,4 in of Hg) Pressure transmitter Settings: 4 mA 0,02 mA for 0,800 bar (23,6 in of Hg), 20 mA 0,10 mA for 1,200 bar (35,4 in of Hg) Pressure transmitter Settings: 4 mA 0,02 mA for 0,800 bar (23,6 in of Hg), 20 mA 0,10 mA for 1,200 bar (35,4 in of Hg) Compressor Discharge Pressure Transmitter Settings: 4 0.05 for 0 bar ( 0 psi ) 20 0.05 for 21 bar ( 304.5 psi ) Pressure transmitter Settings: 4 mA 0,02 mA for 0,0000 bar, 20 mA 0,10 mA for 0,0274 bar (11 in of H2O) Fuel Gaz inter-valve Pressure Transmitter Settings: 0 0,05V for 0 bar (0 psi) 5 0,05 V for 34,5 bar (500 psi) Fuel Gaz inter-valve Pressure Transmitter Settings: 0 0,05V for 0 bar (0 psi) 5 0,05 V for 34,5 bar (500 psi) Fuel Gaz inter-valve Pressure Transmitter Settings: 0 0,05V for 0 bar (0 psi) 5 0,05 V for 34,5 bar (500 psi) Exhaust Pressure Transmitter Settings: 4 0,05 mA for 0 bar ( 0 psi) 20 0,1 mA for 35 bar (510 psi) Gas control valve LVDT Settings: 0,7 0,01 VAC for 0 mm Lube Oil header Pressure transducer Settings: 4 0,05 mA for 0 bar (0 psi) 20 0,1mA for 7 bar (101,5 psi) Header end Lube Oil Pressure transducer Settings: 4 0,05 mA for 0 bar (0 psi) 20 0,1mA for 5 bar (72,51 psi) Stop Ratio Fuel Gaz (VSR-1) LVDT Settings: 0.7 0,01 VAC for 0 mm Torque Converter IGV Position Transmitter Settings: 4 0,05 for 0 tr 20 0,05 for 31 tr Inlet Guide Vane LVDT Settings: 0,7 0,01 VAC for 34 Inlet Guide Vane Actuator LVDT (Linear variable displacement transmitter) Settings: 0,7 0,01 VAC for 34 DWG NO
0415 95TR-13 0415 95TR-14 0425 96AD-1 0492 96AP-1A 0492 96AP-1B 0492 96AP-1C 0417 96CD-1C 0492 96CS-1 0422 96FG-2A
0422 96FG-2B
0557
0422 96FG-2C
0557
0416 96QT-2A 0422 96SR-1,2 0421 96TM-1 0469 96TV-1 0469 96TV-2
SIZE
CAGE CODE
g
DRAWN
381A6409
A4
SECTION 01E
SCALE SHEET
22
SIZE
DWG NO
A4
Item Devices PID 0415 96VC-11 0415 96VC-12
381A6409
Item TG 0235 0235
SH
23
REV
Designation Vibration Sensor Settings: -10,5 0,5 VDC Vibration Sensor Settings: -10,5 0,5 VDC water injection skid inlet absolute pressure transmitter Characteristics: 1600 PSI | 0 40 PSI to 0 800 PSI | -40 to +185 F | 10.5 to 36 V CC | 4 20 mA Settings: 4 0,05 mA = 0 bar 20 0,1 mA = 5.5 bar Water injection pump outlet relative pressure transmitter Characteristics: 2030 PSI | 0 1000 PSI to 0 5996 PSI | -22 to +194 F | 12 to 45 V CC | 4 20 mA Settings: 4 0,05 mA = 0 bar 20 0,1 mA = 68,9 bar Water injection pump outlet differential pressure transmitter Characteristics: 2030 PSI | 0 166.8 PSI to 0 1000 PSI | -22 to +194 F | 12 to 45 V CC | 4 20 mA Settings: 4 0,05 mA = 0 bar 20 0,1 mA = 3,45 bar Atomizing air precooler air discharge thermocouple. Characteristics: Type K Atomizing air precooler air discharge thermocouple. Characteristics: Type K Control oil hydraulic accumulator Characteristics: Capacity : 2,5 gal | Nitrogen Settings: 51,7 1 bar (750 15 psi) Control oil hydraulic accumulator Characteristics: Capacity : 2,5 gal | Nitrogen Settings: 51,7 1 bar (750 15 psi) Load compartment temperature Characteristics: PT100 | 100 ohms at 0C | 0,385 ohm / C | Turbine compartment temperature Characteristics: PT100 | 100 ohms at 0C | 0,385 ohm / C | Water injection common circuit accumulator-hale Characteristics: Capacity : 0,264 gal Settings: Precharge : 435 psig Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Main atomizing air compressor. Characteristics: Centrifugal | 2,7kg/s | 6500 rpm Booster Atomizing Air Compressor. Characteristics: Volumetric | 510m3/h | 6200 rpm Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO
0462 96WN-1
A035
0462 96WN-3
A035
0462 96WN-4
A035
0434 AH1-2 0436 AT-LC-1 0436 AT-TC-1 0462 AW-1 0415 BT-J1-1A,1B 0415 BT-J1-2A,2B 0415 BT-J2-1A,1B 0415 BT-J2-2A,2B 0415 BT-J3-1A,1B 0415 BT-J3-2A,2B 0415 BT-TA1-2A,2B 0415 BT-TA1-5A,5B 0415 BT-TA1-8A,8B 0415 BT-TI1-2A,2B 0415 BT-TI1-5A,5B 0415 BT-TI1-9A,9B 0425 CA1 0425 CA2 0415 CT-DA-1 0415 CT-DA-2
0502 0637 0637 A035 0235 0235 0235 0235 0235 0235 0235 0235 0235 0235 0235 0235 0607 1047 0637 0637
g
DRAWN
381A6409
A4
SECTION 01E
SCALE SHEET
23
SIZE
DWG NO
A4
Item Devices PID 0415 CT-IF-1 0415 CT-IF-2 0477 0425 0477 0462 FA3-1 FA4-1 FA6-1 FA90-1
381A6409
Item TG 0637 0637 0918T 0983 1015 A035 0613 1024 1051 1051 0992 0548 0911 0909 A035 A035 A035 A035 0605 0548 1003 0637 0637 0637 0637 ALT./ GEN. ALT./ GEN. 0938 0938 0637 0637 0637 0512 0611 0627 0628 A035 0931 1104 Encl.
SH
24
REV
Designation Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Liquid fuel purge air filter. Atomizing air actuation air filter. Filter on actuation air of fuel gas purge air valves. Strainer on control air supply circuit Flow divider Characteristics: Volumetric | 883 l/min | 1650 Hz | 1650 tr/min HP fuel filter HP fuel filter Hydraulic supply filter Hydraulic supply filter Hydraulic supply filter-liquid fuel servo IGV controller assembly hydraulic oil supply filter Servo hydraulic supply filter of Gas fuel control & stop valve control air Filter 1 air supplied from Compressor discharge Water injection common flow meter Characteristics: Flow range : 16 to 130 GPM Water injection system low pressure strainer Water injection system main filter High pressure strainer downstream flow meter water injection Torque Converter and Reversing Gear Characteristics: Driven at 3000 rpm approximatively Actuator assembly, Inlet Guide Vane System Settings: Actuator operation limits : 32 to 86 Atomizing air precooler. Lube Oil Thermocouple #1 Bearing Drain Characteristics: Type K Lube Oil Thermocouple #2 Bearing Drain Characteristics: Type K Lube Oil Thermocouple #3 Bearing Drain Characteristics: Type K Lube Oil Thermocouple #1 Bearing Drain Characteristics: Type K Lube Oil Thermocouple generator #1 Bearing Drain Characteristics: Type K Lube Oil Thermocouple generator #2 Bearing Drain Characteristics: Type K Lube oil tank resistance temperature detector Characteristics: Type K Lube oil tank resistance temperature detector Characteristics: Type K Lube oil temperature turbine header thermocouple Characteristics: Type K Lube oil temperature turbine header thermocouple Characteristics: Type K Lube oil temperature turbine header thermocouple Characteristics: Type K Gas fuel nozzle Main fuel Pump Characteristics: Volumetric | 870.5 l/min | 68.9 bar | 1550 tr/min Main hydraulic supply pump Characteristics: Volumetric positive displacement 65 l/min (17,1 GPM) |105 bar (1500 psi) | 1422 tr/min (1422 RPM) Auxiliary hydraulic supply pump Characteristics: Volumetric 45,4 l/min (12 GPM) | 105 Bar (1500 psi) |1450 tr/min (1450 RPM) Water injection centrifugal fixed speed pump Air Cleaner Light warning accessory compartment Characteristics: 230 VAC-50/60 Hz Fire alarm : flashing light unit Characteristics: 24VDC GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO
0424 FD1-1 0424 0424 0434 0434 0424 0469 0422 0417 FF2-1 FF2-2 FH2-1 FH2-2 FH3-1 FH6-1 FH7-1 Filtre
0462 FM1-1 0462 FW1-1 0462 FW2-1 0462 FW3-1 0421 HM1 0469 HM3-1 0425 HX1-1 0416 LT-B1D-1A,1B 0416 LT-B2D-1A,1B 0416 LT-B3D-1A,1B 0416 LT-BT1D-1A,1B 0416 LT-G1D 0416 LT-G2D 0416 LT-OT-1A 0416 LT-OT-2A 0416 LT-TH-1A,1B 0416 LT-TH-2A,2B 0416 LT-TH-3A,3B 0422 MG1 0424 PF1 0434 PH1 0434 PH2 0462 PW1-1 0417 Separateur 0426 SLI-1 0426 SLI-1A
g
DRAWN
381A6409
A4
SECTION 01E
SCALE SHEET
24
SIZE
DWG NO
A4
Item Devices PID 0426 SLI-1B 0426 SLI-1C 0426 SLI-2 0426 SLI-2C 0426 SLI-3C 0415 TT-IB-1 0415 TT-WS1A0-1 0415 TT-WS1A0-2 0415 TT-WS1FI-1 0415 TT-WS1FI-2 0415 TT-WS2A0-1 0415 TT-WS2A0-2 0415 TT-WS2F0-1 0415 TT-WS2F0-2 0415 TT-WS3A0-1 0415 TT-WS3A0-2 0415 TT-WS3F0-1 0415 TT-WS3F0-2 0415 TT-XD-1 0415 TT-XD-10 0415 TT-XD-11 0415 TT-XD-12 0415 TT-XD-13 0415 TT-XD-14 0415 TT-XD-15 0415 TT-XD-16 0415 TT-XD-17 0415 TT-XD-18 0415 TT-XD-19 0415 TT-XD-2 0415 TT-XD-20 0415 TT-XD-21
381A6409
Item TG Encl. Encl. 1104 Encl. Encl. 0637 0637 0637 0637 0637 0637 0637 0637 0637 0637 0637 0637 0637 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623
SH
25
REV
Designation Fire alarm : flashing light unit Characteristics: 24VDC Fire alarm : horn and flashing light unit load Characteristics: 24VDC Light warning accessory compartment Characteristics: 230 VAC-50/60 Hz Fire alarm : horn and flashing light unit load Characteristics: 24VDC Fire alarm : horn and flashing light unit load Characteristics: 24VDC Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO
g
DRAWN
381A6409
A4
SECTION 01E
SCALE SHEET
25
SIZE
DWG NO
A4
Item Devices PID 0415 TT-XD-22 0415 TT-XD-23 0415 TT-XD-24 0415 TT-XD-3 0415 TT-XD-4 0415 TT-XD-5 0415 TT-XD-6 0415 TT-XD-7 0415 TT-XD-8 0415 TT-XD-9 0477 VA13-1 0477 VA13-2 0424 VA17-1 0424 VA17-2 0424 VA17-5 0425 VA18-1 0477 VA19-1 0417 VA2-1 0417 VA2-2 0425 VA22-1 0417 VA2-3 0417 VA2-4 0434 VAB1 0434 VAB2 0424 VC3-1 0462 VC4-1 0462 VC5-1 0424 VCK1-1T14
381A6409
Item TG 0623 0623 0623 0623 0623 0623 0623 0623 0623 0623 0918 0918 1026 1026 1026 1070 0918T 1022 1022 0922 1022 1022 0947 0947 0516 A035 A035 0961
SH
26
REV
Designation Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Thermocouple Characteristics: Type K Gas fuel purge air valve. Characteristics: Normal: NC Gas fuel purge air valve. Characteristics: Normal: NC False start drain valve-combustion wrapper Settings: Normal : NO False start drain valve-exhaust frame Settings: Normal : NO False start drain valve-exhaust plenum Characteristics: Normal : NO Atomizing air compressor by pass valve. Characteristics: Normal: NC Liquide fuel purge air valve. Characteristics: Normal : C to L opened ; U closed Compressor Bleed valve 11th stage Characteristics: Normal : NO Compressor Bleed valve 11th stage Characteristics: Normal : NO Booster atomizing air compressor isolating valve. Characteristics: Normal: NO Compressor Bleed valve 11th stage Characteristics: Normal : NO Compressor Bleed valve 11th stage Characteristics: Normal : NO Hydraulic system air bleed valve (main) Hydraulic system air bleed valve (aux.) By pass control valve Characteristics: Normal : NO Stroke : 1,125 in Water injection flow control valve primary circuit Characteristics: Normal: NC Big flow manifold water injection transfer valve Characteristics: Normal: NC Liquid fuel nozzle check valve Characteristics: Normal: NC Cracking press : 8,27 0,34 Bar (120 5 psig) Liquid fuel nozzle purge air check valve. Characteristics: Normal: NC Cracking pressure 0.34 0.07 bar (4.93 1 psi). Hydraulic pump check valve for main pump Hydraulic pump check valve for auxiliary pump Turbine Shell and Exhaust Frame Blower Check Valve Characteristics: Normal : NC Turbine Shell and Exhaust Frame Blower Check Valve Characteristics: Normal : NC GENERAL ELECTRIC COMPANY SIZE CAGE CODE DWG NO
0477 VCK2-1T14 0434 VCK3-1 0434 VCK3-2 0417 VCK7-1 0417 VCK7-2
g
DRAWN
381A6409
A4
SECTION 01E
SCALE SHEET
26
SIZE
DWG NO
A4
Item Devices PID 0422 VGC 0422 VH12 0469 VH3-1 0422 VH5 0434 VM4 0424 VP-1 0424 VP-2 0416 VPR2-1 0434 VPR3-1 0477 VPR44-1 0477 VPR44-2 0477 VPR54-1 0462 VPR62-11 0425 VPR68-1 0462 VPR90-1 0462 VPR90-2 0462 VQE-1 0416 VR1 0434 VR21 0434 VR22 0424 VR27
381A6409
Item TG 0509 0509 0540 0507 1052 0961 0961 1023 0627 0918 0918 0918 A035 0922 A035 A035 A035 1016 0947 0947 0992
SH
27
REV
Designation Gas control valve Characteristics: Normal : NC stroke maxi : 44,5 0,5 mm VGC trip valve Characteristics: Normal : NO Trip relay, hydraulic, IGV VSR security discharge valve Characteristics: Normal : NO Hydraulic filter transfer valve Fuel liquid purge multiport valve Fuel liquid purge multiport valve Bearing header pressure regulator valve Characteristics: Normal : NC Settings: Set point : 1,72 + 0,13 /-0 bar (25 + 2 /-0 psi) Hydraulic supply pump (PH1) compensator Settings: Setting : 1500 +20/-0 psig Filter pressure regulator on actuation air of gas fuel purge air valve. Settings: 2,3 +0/-0,2 bar (33,35 +0/-2,9 psi) Filter pressure regulator on actuation air of gas fuel purge air valve. Settings: 2,3 +0/-0,2 bar (33,35 +0/-2,9 psi) Filter pressure regulator on actuation air of liquid fuel purge air valve. Settings: 3,27 +1,7/-0 bar (47,5 +2,7/-0 psi) Water injection stop valve pressure regulator Characteristics: Normal : NC Settings: 6,9 0.340 bar (100 4,9 psi) Instrumentation air filter pressure regulator on VA22-1 actuation. Settings: 3,79 0,13 bar (55 2 psi) Water injection VC4-1 transfer valve air pressure regulation Settings: Setting: 2 +0.4/-0 bar Water injection VC5-1 transfer valve air pressure regulation Settings: Setting: 2 +0.4/-0 bar Quick exhaust valve Characteristics: Normal : NC Main lube oil pump pressure relief valve Characteristics: Normal : NC Settings: Opening at 6,89 + 0,13/-0 bar (100 + 2/-0 psi) Main hydraulic supply pump pressure relief valve Settings: 1650 20 psi Auxiliary hydraulic supply pump pressure relief valve Settings: Setting : 1650 20 psig Pressure relief valve on liq. fuel piping Characteristics: Normal: NC Settings: Setting : 6 0,2 bar (87 2,9 psi) Main fuel pump pressure relief valve Characteristics: Normal : NC Settings: Setting : 82,7 1,72 bar (1200 25 psi) Fuel oil stop valve Characteristics: Normal : NC Water injection stop valve Characteristics: Normal : NC Fuel gas stop/speed ratio valve Characteristics: Normal : NC | stroke maxi : 88,67 mm ( 3,5 in) Brg header temperature regulator valve Characteristics: Normal: E to B open, C closed. Settings: Starts to open at Oil T = 130 3.6 F. Atmg air precooler air discharge temp.rgltr valve Characteristics: Normal: B to E open, C closed. Settings: T air = 225 3.6 F Resistance thermometer detector Support legs water temperature Characteristics: Platine PT100 | 100 Ohm at 32F | 0,214 Ohm / F | -58 to 500 F Resistance thermometer detector Support legs water temperature Characteristics: Platine PT100 | 100 Ohm at 32F | 0,214 Ohm / F | -58 to 500 F
0424 VR4 0424 VS1 0462 VS2-1 0422 VSR 0420 VTR1
SIZE
CAGE CODE
DWG NO
g
DRAWN
381A6409
A4
SECTION 01E
SCALE SHEET
27