PTN Huawei
PTN Huawei
PTN Huawei
Product Description
Issue Date
01 2011-06-30
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied.
Issue 01 (2011-06-30)
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Intended Audience
This document describes the OptiX OSN 550 in terms of network application, function, hardware architecture, software architecture, features, and technical specifications. This document is intended for the following engineers: Network planning engineers Data configuration engineers System maintenance engineers
Symbol Conventions
The symbols that may be found in this document are defined as follows. Symbol Description Indicates a hazard with a high level of risk, which if not avoided, will result in death or serious injury. Indicates a hazard with a medium or low level of risk, which if not avoided, could result in minor or moderate injury. Indicates a potentially hazardous situation, which if not avoided, could result in equipment damage, data loss, performance degradation, or unexpected results.
Issue 01 (2011-06-30)
ii
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Symbol
Description Indicates a tip that may help you solve a problem or save time. Provides additional information to emphasize or supplement important points of the main text.
GUI Conventions
Convention Boldface > Meaning Buttons, menus, parameters, tabs, window, and dialog titles are in boldface. For example, click OK. Multi-level menus are in boldface and separated by the ">" signs. For example, choose File > Create > Folder.
Change History
Updates between document issues are cumulative. Therefore, the latest document issue contains all updates made in previous issues.
Issue 01 (2011-06-30)
iii
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Contents
Contents
About This Document.................................................................................................................... ii 1 Product Positioning and Features .............................................................................................. 1
1.1 Product Positioning.................................................................................................................... 1
3.1 System Architecture ..................................................................................................................11 3.2 Hardware Structure ...................................................................................................................12 3.3 Software Architectu re................................................................................................................20 3.3.1 Overview of Software Architecture.......................................................................................21 3.3.2 Communication Protocols and Interfaces ...............................................................................21 3.3.3 Board Software ................................................................................................................22 3.3.4 NE Software ....................................................................................................................22 3.3.5 NMS Software .................................................................................................................23
4.1 Packet-Domain Access Capacity .................................................................................................24 4.2 Service Support........................................................................................................................24 4.2.1 Native Ethernet Services ....................................................................................................25 4.2.2 ETH PWE3 Services .........................................................................................................34 4.2.3 CES Services ...................................................................................................................35 4.2.4 A TM/IMA Services ...........................................................................................................37 4.3 Protection Support....................................................................................................................38 4.3.1 MPLS APS ......................................................................................................................38 4.3.2 PW APS..........................................................................................................................40 4.3.3 LPT................................................................................................................................41 4.3.4 LAG...............................................................................................................................42 4.4 Maintenance............................................................................................................................43 4.4.1 MPLS OAM ....................................................................................................................44 4.4.2 ETH-OAM ......................................................................................................................44 4.4.3 A TM OAM......................................................................................................................46 4.4.4 RMON ...........................................................................................................................46
Issue 01 (2011-06-30)
iv
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Contents
4.4.5 PRBS .............................................................................................................................47 4.4.6 CES Alarm Transmission....................................................................................................47 4.5 Synchronization .......................................................................................................................49 4.5.1 Synchronous Ethernet Clock ...............................................................................................49 4.5.2 CES ACR ........................................................................................................................49
5.1 TDM-Domain Access Capacity ...................................................................................................51 5.2 Service Support........................................................................................................................51 5.3 Protection Support....................................................................................................................52 5.3.1 SNCP .............................................................................................................................52 5.3.2 Ring MSP........................................................................................................................53 5.3.3 Linear MSP .....................................................................................................................55 5.4 Maintenance............................................................................................................................57 5.5 Synchronization .......................................................................................................................58
6.1 Basic Network Topologies..........................................................................................................59 6.2 Typical Application of Hybrid Networking ....................................................................................60 6.3 Typical Application of Pure Packet Networking ..............................................................................61 6.4 Typical Application of TDM Networking ......................................................................................63
7 Security Management................................................................................................................. 65
7.1 Authentication Management .......................................................................................................65 7.2 Authorization Management ........................................................................................................65 7.3 Network Security Management ...................................................................................................66 7.4 System Security Management .....................................................................................................67 7.5 Log Management .....................................................................................................................67
8.1 DCN......................................................................................................................................69 8.2 Equipment Maintenance ............................................................................................................70 8.3 Upgrade Methods .....................................................................................................................72 8.4 License Control........................................................................................................................74
9.1 General Speci fications ...............................................................................................................75 9.2 Packet Performan ce Indicators ....................................................................................................76 9.3 TDM Perfo rmance Indicators ......................................................................................................81 9.4 Power Consumption and Weight of Each Board ..............................................................................82 9.5 Optical Port Specifications .........................................................................................................82 9.6 Electrical Port Specifications ......................................................................................................87 9.7 Auxiliary Port Specifications ......................................................................................................89 9.8 Optical Module Specifications ....................................................................................................91 9.9 Indicator Status Explanation .......................................................................................................93
Issue 01 (2011-06-30)
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Contents
9.10 Safety Certifi cation .................................................................................................................96 9.11 Environmental Specifications ....................................................................................................96 9.11.1 Storage Environment........................................................................................................97 9.11.2 Transportation Environment ..............................................................................................99 9.11.3 Operation Environment .................................................................................................. 101
A.1 Numerics ............................................................................................................................. 114 A.2 A ........................................................................................................................................ 114 A.3 B ........................................................................................................................................ 117 A.4 C ........................................................................................................................................ 118 A.5 D........................................................................................................................................ 121 A.6 E ........................................................................................................................................ 123 A.7 F ........................................................................................................................................ 125 A.8 G........................................................................................................................................ 127 A.9 H........................................................................................................................................ 128 A.10 I ....................................................................................................................................... 129 A.11 J ....................................................................................................................................... 130 A.12 L....................................................................................................................................... 130 A.13 M...................................................................................................................................... 132 A.14 N ...................................................................................................................................... 134 A.15 O ...................................................................................................................................... 135 A.16 P....................................................................................................................................... 136 A.17 Q ...................................................................................................................................... 139 A.18 R ...................................................................................................................................... 139 A.19 S....................................................................................................................................... 141 A.20 T....................................................................................................................................... 145 A.21 U ...................................................................................................................................... 146 A.22 V ...................................................................................................................................... 147 A.23 W...................................................................................................................................... 147
Issue 01 (2011-06-30)
vi
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Figures
Figures
Figure 1-1 Product positioning and typical application of the OptiX OSN 550........................................... 1 Figure 3-1 Block diagram...............................................................................................................11 Figure 3-2 Ventilation design of the OptiX OSN 550 ...........................................................................19 Figure 3-3 General architecture o f software .......................................................................................21 Figure 4-1 Typical application of service model 1 ...............................................................................26 Figure 4-2 Model of VLAN-bas ed E-Line services ..............................................................................27 Figure 4-3 Typical application of service model 1 ...............................................................................29 Figure 4-4 Typical application of service model 2 ...............................................................................29 Figure 4-5 Typical application of service model 3 ...............................................................................30 Figure 4-6 Typical application of service model 4 ...............................................................................30 Figure 4-7 Model of E-LAN services based on the 802.1d bridge...........................................................31 Figure 4-8 Model of E-LAN services based on 802.1q bridge................................................................32 Figure 4-9 Model of E-LAN services based on 802.1ad bridge ..............................................................34 Figure 4-10 E-Line services carried by PWs.......................................................................................35 Figure 4-11 UNI-UNI CES services..................................................................................................36 Figure 4-12 UNI-NNI CES services .................................................................................................36 Figure 4-13 Typical application of ATM PWE3 (in the one-to-one encapsulation mode) .............................37 Figure 4-14 Typical application of ATM PWE3 (in the N-to-one encapsulation mode)................................38 Figure 4-15 Application example of MPLS APS .................................................................................40 Figure 4-16 Application example of PW APS .....................................................................................41 Figure 4-17 Typical application of LPT .............................................................................................42 Figure 4-18 Link aggregation group .................................................................................................43 Figure 4-19 Application of IEEE 802.1ag and IEEE 802.3ah .................................................................45 Figure 4-20 Typical application of ATM OAM ...................................................................................46 Figure 4-21 CES alarm transparent transmission between AC sides ........................................................48 Figure 4-22 CES alarm transparent transmission from the NNI side to the AC side....................................48
Issue 01 (2011-06-30)
vii
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Figures
Figure 4-23 CES ACR clock solution................................................................................................50 Figure 5-1 Application of the SNCP .................................................................................................53 Figure 5-2 Two-fiber unidirectional ring MSP ....................................................................................54 Figure 5-3 Two-fiber bidirectional ring MSP ......................................................................................55 Figure 5-4 1+1 linear MSP .............................................................................................................56 Figure 5-5 1:N linear MSP..............................................................................................................57 Figure 6-1 Hybrid ring network .......................................................................................................60 Figure 6-2 Board configurations on each NE of the Hybrid ring network .................................................61 Figure 6-3 Pure packet network .......................................................................................................62 Figure 6-4 Board configurations on each NE of the pure packet network .................................................62 Figure 6-5 TDM network ...............................................................................................................63 Figure 6-6 Board configurations on each NE of the TDM network .........................................................64 Figure 7-1 Log transmission of the Syslog protocol .............................................................................68
Issue 01 (2011-06-30)
viii
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Tables
Tables
Table 2-1 Overview of the OptiX OSN 550......................................................................................... 3 Table 2-2 OptiX OSN 550 packet fun ctions and features ........................................................................ 5 Table 2-3 OptiX OSN 550 TDM functions and features ......................................................................... 9 Table 3-1 Function units of the OptiX OSN 550..................................................................................11 Table 3-2 Boards that the OptiX OSN 550 supports .............................................................................13 Table 3-3 Description of labels ........................................................................................................19 Table 4-1 Packet-domain access cap acity o f the OptiX OSN 550............................................................24 Table 4-2 Point-to-point transparently transmitted E-Line service model ..................................................25 Table 4-3 Models of VLAN-b ased E-Line servi ces ..............................................................................26 Table 4-4 Models of QinQ-bas ed E-Line Services ...............................................................................27 Table 4-5 Model of E-LAN servi ces based on the 802.1d bridge ............................................................31 Table 4-6 Model of E-LAN servi ces based on 802.1q bridge .................................................................32 Table 4-7 Models of E-LAN servi ces based on 802.1ad bridge...............................................................33 Table 5-1 TDM-domain access capacity of the OptiX OSN 550 .............................................................51 Table 5-2 Service types supported by the OptiX OSN 550 in the TDM domain .........................................51 Table 6-1 Network topologies supported by OptiX OSN 550s and corresponding legends ...........................59 Table 8-1 DCN solutions that the OptiX OSN 550 supports...................................................................69 Table 8-2 Maintenance fun ctions that the OptiX OSN 550 supports ........................................................70 Table 8-3 Upgrade methods available for the OptiX OSN 550 ...............................................................73 Table 9-1 General speci fications of the OptiX OSN 550 .......................................................................75 Table 9-2 OptiX OSN 550 packet fun ctions and features .......................................................................76 Table 9-3 OptiX OSN 550 TDM functions and features ........................................................................81 Table 9-4 Power consumption and weight of boards supported by the OptiX OSN 550...............................82 Table 9-5 Specifi cations of OptiX OSN 550's STM-1 optical ports .........................................................83 Table 9-6 Specifi cations of OptiX OSN 550's STM-4 optical ports .........................................................83 Table 9-7 Specifi cations of OptiX OSN 550's STM-16 optical ports........................................................84
Issue 01 (2011-06-30)
ix
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Tables
Table 9-8 Specifi cations of FE optical ports of the OptiX OSN 550 ........................................................85 Table 9-9 Specifi cations of OptiX OSN 550's GE optical ports ..............................................................86 Table 9-10 Specifi cations of 10GE optical ports of the OptiX OSN 550...................................................86 Table 9-11 Specifications of OptiX OSN 550's E1/T1 electrical ports ......................................................87 Table 9-12 Specifi cations of OptiX OSN 550's E3/T3 electrical ports......................................................88 Table 9-13 Specifi cations of OptiX OSN 550's CES/A TM/IMA service electri cal ports...............................88 Table 9-14 Specifi cations of OptiX OSN 550's Ethernet electrical ports ...................................................89 Table 9-15 Specifi cations of external clock ports supported by the OptiX OSN 550 ...................................89 Table 9-16 Specifi cations of synch ronous data ports supported by the OptiX OSN 550...............................90 Table 9-17 Specifi cations of asyn chronous data ports supported by the OptiX OSN 550 .............................90 Table 9-18 Specifi cations of ord erwire ports supported by the OptiX OSN 550.........................................90 Table 9-19 Outdoor cabinet monitoring ports supported by the OptiX OSN 550........................................91 Table 9-20 SFP/eSFP Optical Modules That the OptiX OSN 550 Supports...............................................91 Table 9-21 XFP Optical Modules That the OptiX OSN 550 Supports ......................................................92 Table 9-22 Definitions of indicators supported by the boards on the OptiX OSN 550 .................................93 Table 9-23 Safety certi fications that the OptiX OSN 550 has passed .......................................................96 Table 9-24 Climate requirements for the storage envi ronment ................................................................97 Table 9-25 Density requirements for mechani cal active substances during storage .....................................98 Table 9-26 Density requirements for chemically active substances during storage......................................98 Table 9-27 Limitations for mech anical stress during storage ..................................................................98 Table 9-28 Climate requirements for the transport ation environment .......................................................99 Table 9-29 Density limitations for mechanically active substances during transportation ........................... 100 Table 9-30 Density limitations for chemically active substances ........................................................... 100 Table 9-31 Mechanical stress requirements for the transportation environment ........................................ 100 Table 9-32 Requirements for temperature and humidity...................................................................... 101 Table 9-33 Other climate requirements ............................................................................................ 102 Table 9-34 Density limitations for mechanically active substances during operation ................................. 102 Table 9-35 Density limitations for chemically active substances ........................................................... 103 Table 9-36 Limitations for mech anical stress during operation ............................................................. 103 Table 11-1 ITU-T recommendations ............................................................................................... 105 Table 11-2 IETF standards ............................................................................................................ 108 Table 11-3 IEEE standards ............................................................................................................ 110 Table 11-4 Environment related standards ........................................................................................ 111
Issue 01 (2011-06-30)
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Tables
Issue 01 (2011-06-30)
xi
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
E1/T1 FE E1/T1 FE
E1/T1 STM-1/ STM-4 E1/T1 TDM netw ork STM-1/ STM-4 FE/ GE FE/ GE Pack et n etwo rk FE/GE
NodeB
BTS
RNC
BSC
Issue 01 (2011-06-30)
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Issue 01 (2011-06-30)
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
2 Quick Referen ce
2
Table 2-1 lists the overview of the OptiX OSN 550. Table 2-1 Overview of the OptiX OSN 550 Item Appearance Description
Quick Reference
This section describes the product overview, including product photos, hardware, software, and functions and features.
Board Packet Function and Feature TDM Function and Feature Switching Capacity Cross-connec t capacity Equipment-L evel Protection
60/40/20 Gbit/s Higher order cross-connect capacity: 20 Gbit/s Lower order cross-connect capacity: 5 Gbit/s 1+1 backup for power supply 1+1 backup between active and standby system control, switching, and timing boards LAG protection of the ports on Ethernet boards Fan protection (The failure of a single fan does not affect the operation of the other fans.)
Issue 01 (2011-06-30)
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
2 Quick Referen ce
Description Intellectual adjustment of the fan speed. When the working temperature of the equipment is lower than the threshold (determined by the measured ambient temperature and the current fan speed), the fan speed automatically reduces to the lowest. Interface Type Clock port Description 120-ohm external clock port, which can work in 2048 kbit/s mode or 2048 kHz mode. Power supply port connecting to one -48/-60 V DC power supply T wo 100/240 V AC power supply ports Network management port Alarm input/output port 64 kbit/s synchronous data or orderwire byte transparent transmission port/19.2 kbit/s asynchronous data or orderwire byte transparent transmission port Orderwire phone port Ethernet NM port/NM serial port, which is connected to the network management system (NMS) Alarm input/output Connector RJ-45
2 mm HM connector
RJ-45
One 64 kbit/s synchronous serial port, and one F2 transparent data port, which transparently transmits one channel of data services.
RJ-45
Used to provide voice communication for operation personnel or maintenance personnel at different workstations.
RJ-45
Issue 01 (2011-06-30)
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
2 Quick Referen ce
Table 2-2 OptiX OSN 550 packet functions and features Item MPLS suppo rt capab ility Description The packet switching unit of the PCX board works with a service board to implement MPLS functions. Setup mode: static LSPs Protection: 1:1 MPLS tunnel APS OAM: Supports MPLS OAM that complies with ITU-T Y.1711. Supports LSP ping and LSP traceroute functions. The packet switching unit of the PCX board works with a service board to implement PWE3 functions. Service categories TDM PWE3 (CES) services ATM PWE3 services ETH PWE3 services Setup mode: static PWs Protection: 1:1 PW APS OAM: Support the ping and traceroute commands of PWs, the virtual circuit connectivity verification (VCCV) command. Supports PW OAM that complies with ITU-T Y.1711. Supports MS-PWs. Service Type Description Maximum Re ceiving Capability FE (electrical port): 36 FE (optical port): 48 Service Port Descriptio n Connector
Servic e
Etherne Supports Native ETH t and ETH PWE3 service services. Format of Ethernet data frames: IEEE
Issue 01 (2011-06-30)
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
2 Quick Referen ce
Item
Description 802.3 and Ethernet 10GE II (optical Jumbo frames port) MTU length: 1518 PCXLX/ bytes to 9600 bytes PCXX: 2 (1620 bytes, by default) MPLS function support VLAN function support. The VLAN IDs range from 1 to 4094. QinQ support Size of a MAC address table: 16 KB (including static entries) GE (optical port) PCXLG/ PCXGA/ PCXGB: 14 GE (electrical port): 12 CES service Service type: 192xE1 point-to-point service Encapsulation types: CESoPSN SAToP Compression of idle timeslots: supported (only for CESoPSN encapsulation) Jitter compensation buffering time: 375 us to 16000 us Packet loading time: 125 us to 5000 us CES ACR: supported Retiming: supported 10GBAS E-LR (LAN) 10GBAS E-LW (WAN) 10GBAS E-ER (LAN) 10GBAS E-EW (WAN) 10GBAS E-ZR (LAN) 10GBAS E-ZW (WAN) 1000Base -LX 1000Base -VX 1000Base -ZX 10/100/100 0BASE-TX 75/120-oh m smart E1 port LC
LC
RJ-45
Anea 96
Issue 01 (2011-06-30)
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
2 Quick Referen ce
Item
Description ATM/I MA service Number of ATM connections: 256 ATM traffic management ATM encapsulation format N-to-one VPC N-to-one VCC One-to-one VPC One-to-one VCC Maximum number of concatenated ATM cells: 31 ATM OAM: F4 (VP layer) and F5 (VC layer) Maximum number of IMA groups: 32 Maximum number of members in an IMA group: 16 192xE1 75/120-oh m smart E1 port Anea 96
Protec tion
MPLS APS
Maximum number of protection groups: 64 Switching duration not more than 100 ms
NOTE MP LS AP S and P W AP S share 64 protection group resources.
PW APS
Maximum number of protection groups: 64 Switching duration not more than 100 ms
NOTE MP LS AP S and P W AP S share 64 protection group resources.
MSTP
Supports the MSTP protocol that generates only the CIST . The MSTP protocol provides functions equivalent to that of the RSTP protocol. Point-point and point-multipoint LPT Switching duration not more than 5s Intra-board LAG and inter-board LAG A maximum of 16 LAGs. Each LAG has a maximum of 8 members. Switching duration not more than 500 ms T unnel OAM and PW OAM Maximum number of MPLS OAM resources: 128
NOTE MP LS OAM and P W OAM share 128 OAM resources.
LPT LAG
Maint enanc e
MPLS OAM
Issue 01 (2011-06-30)
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
2 Quick Referen ce
Item
Description ETH-O AM Supports the following IEEE 802.1ag OAM functions: Management of OAM maintenance points Continuity check (CC) Loopback (LB) Link trace (LT) Supports the following IEEE 802.3ah OAM functions: OAM auto-discovery Link performance monitoring Fault detection Loopback at the remote end Self-loop detection and self-looped port blocking Number of MD/MA/MEP: 64
Maximum number of ATM connections: 256 Supports port-level and service-level RMON functions, in compliance with RFC 2819. Supports four RMON management groups: Ethernet statistics group, Ethernet history group, Ethernet alarm group, and Ethernet history control group. Port level: Basic Ethernet performance Extended Ethernet performance Service level: L2VPN T unnel PW Synchronous Ethernet that complies with ITU-T G.8261 and ITU-T G.8262. Port receiving/transmitting synchronous Ethernet clocks: FE/GE/10GE Input/Output of SSM packets Clock frequency stability (hold-over mode): less than 50 ppb Maximum number of CES ACR clocks: 4 The clock performance complies with the ITU-T G.823 Traffic template. Tributary retiming.
CES ACR
Issue 01 (2011-06-30)
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
2 Quick Referen ce
Item Other s
Description QoS DiffServ Supports simple traffic classification by specifying PHB service classes for service flows based on their QoS information (C-VLAN priorities, S-VLAN priorities, DSCP values, or MPLS EXP values) carried by the packets. Complex traffic classification Supports traffic classification based on C-VLAN IDs, S-VLAN IDs, C-VLAN priorities, S-VLAN priorities, C-VLAN IDs + C-VLAN priorities, S-VLAN IDs + S-VLAN priorities, or DSCP values carried by packets. CAR Provides the CAR function for the traffic flows at ports. Shaping Supports traffic shaping for a specific port, prioritized queue, or traffic flow. Queue scheduling policies SP WRR
SP+WRR
Table 2-3 OptiX OSN 550 TDM functions and features Item Service Description Service Type Re ceiving Capability 26xSTM-1 Service Port Description S-1.1, L-1.1 and L-1.2 optical ports S-4.1, L-4.1 and L-4.2 optical ports S-16.1, L-16.1 and L-16.2 optical ports E1(75/120-oh m)/T1(100-oh m)electrical port Connector LC
SDH service
14xSTM-4
LC
14xSTM-16
LC
PDH service
252xE1/T1
Anea 96
Issue 01 (2011-06-30)
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
2 Quick Referen ce
Item Protection
Description SNCP SNCP at the VC-12/VC-3/VC-4 levels Maximum number of protection groups: 1032 Switching duration not more than 50 ms MSP Ring at the STM-1, ST M-4 and STM-16 levels Maximum number of protection groups: 13 Switching duration not more than 50 ms Linear MSP at the STM-1, STM-4 and STM-16 levels Maximum number of 1+1/1:1 Linear MSP protection groups: 13 Switching duration not more than 50 ms Supported
MSP Ring
Linear MSP
PRBS
Physical layer clocks, including line clocks, tributary clocks, and two-input and two-output external clocks. The port impedance is 120 ohms or 75 ohms (a converter can be used to provide a 75-ohm clock port). Non-synchronization status message (SSM), standard SSM, and extended SSM protocols Tributary retiming Tracing mode, hold-over mode, and free-run mode
Issue 01 (2011-06-30)
10
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
3 Product Architecture
3
3.1 System Architecture
Figure 3-1 Block diagram
Product Architecture
The OptiX OSN 550 is a dual-domain (TDM and packet domains) device. This section describes its function units and the relationship between these units. The OptiX OSN 550 consists of the following function units: service interface unit, timeslot cross-connect unit, packet switching unit, control unit, clock unit, auxiliary interface unit, fan unit, and power supply unit.
VC-4 signal FE/GE E1 (TDM/CES/ATM/IMA) STM-1/4 Ethernet signal Service interface unit
Clo ck unit
Co ntro l unit
Fan unit
NM data
-48 V/-60 V DC
Table 3-1 Function units of the OptiX OSN 550 Function Unit Service interface unit Function Transmits/Receives TDM E1/T1/E3/T3 signals. Transmits/Receives ATM/IMA E1 signals. Transmits/Receives STM-1/4/16 signals. Transmits/Receives Ethernet signals. Performs E1/ATM/Ethernet PWE3 emulation.
Issue 01 (2011-06-30)
11
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
3 Product Architecture
Function Provides the cross-connect function and grooms TDM services. Processes Ethernet services and forwards packets. Processes MPLS labels and forwards packets. Processes PW labels and forwards packets. Performs system communication and control. Configures and manages the system. Collects alarms and monitors performance. Processes overhead bytes. Traces clock sources and provides clock signals for the system. Provides the input/output port for external clocks. Provides the orderwire phone port. Provides the synchronous/asynchronous data port. Provides the external alarm input/output port. Connects to -48 V/-60 V DC power supplies. Connects to 110 to 220 V AC power supplies. Cools the NE.
Control unit
Issue 01 (2011-06-30)
12
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
3 Product Architecture
H D W
SLOT SLOT 10 91 SLOT (PI U) SLOT (PIU) 93 11 SLOT (FAN) SLOT (FA N) 92 9 (PI U) (PIU)
SLOT 7 7 (PCX) SLOT (CS T/CSH) SLOT 5 (EX(EXT) SLOT 5 T) SLOT 3 (EX (EXT) SLOT 3 T) SLOT 1 (EXT ) SLOT 1 ( EXT)
2 3
3 4
Boards
Table 3-2 lists the boards that the OptiX OSN 550 supports. Table 3-2 Boards that the OptiX OSN 550 supports Board Classif ication Board Acron ym Board Name Cross-co nnect, timing and line board Function Service Type Port Type Valid Slot Slots 7 and 8
Supports the 60 Gbit/s packet switching function. Supports the 20 Gbit/s higher
Native Ethernet services Point-to-point transparently transmitted E-Line service VLAN-based E-Line service QinQ-based E-Line
One Ethernet NM port/NM serial port (sharing one RJ45 port) One ST M-1/STM-4/STM-1 6 SFP optical port. The optical port type can be S-1.1, L-1.1, S-4.1, L-4.1, S-16.1, L-16.1, or L-16.2.
Issue 01 (2011-06-30)
13
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
3 Product Architecture
Board Acron ym
Board Name
Function
Service Type
Port Type
Valid Slot
order cross-conn ect capacity, 5 Gbit/s lower order cross-conn ect capacity. Performs system communic ation and control. TNM1 PCXX Cross-co nnect, timing, system control, and line board Supports the 60 Gbit/s packet switching function. Supports the 20 Gbit/s higher order cross-conn ect capacity, 5 Gbit/s lower order cross-conn ect capacity. Performs system communic ation and control. Supports the 40 Gbit/s packet switching function. Supports the 20
service E-LAN service based on IEEE 802.1d bridges E-LAN service based on IEEE 802.1q bridges E-LAN service based on IEEE 802.1ad bridges ETH PWE3 services ST M-1/STM-4/STM -16 services Native Ethernet services Point-to-point transparently transmitted E-Line service VLAN-based E-Line service QinQ-based E-Line service E-LAN service based on IEEE 802.1d bridges E-LAN service based on IEEE 802.1q bridges E-LAN service based on IEEE 802.1ad bridges ETH PWE3 services
One 10GE (XFP) optical port 10GBASE-LR (LAN)/10GBASE-LW (WAN)/10GBASE-ER (LAN)/10GBASE-EW (WAN)/10GBASE-ZR (LAN)/10GBASE-ZW (WAN)
One Ethernet NM port/NM serial port (sharing one RJ45 port) One 10GE (XFP) optical port 10GBASE-LR (LAN)/10GBASE-LW (WAN)/10GBASE-ER (LAN)/10GBASE-EW (WAN)/10GBASE-ZR (LAN)/10GBASE-ZW (WAN)
Slots 7 and 8
TNM1 PCXL G
Native Ethernet services Point-to-point transparently transmitted E-Line service VLAN-based E-Line service
One Ethernet NM port/NM serial port (sharing one RJ45 port) One ST M-1/STM-4/STM-1 6 SFP optical port. The optical port type can be S-1.1, L-1.1, S-4.1,
Slots 7 and 8
Issue 01 (2011-06-30)
14
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
3 Product Architecture
Board Acron ym
Board Name
Function
Service Type
Port Type
Valid Slot
Gbit/s higher order cross-conn ect capacity, 5 Gbit/s lower order cross-conn ect capacity. Performs system communic ation and control. TNM1 PCXG A Cross-co nnect, timing, system control, and line board Supports the 40 Gbit/s packet switching function. Supports the 20 Gbit/s higher order cross-conn ect capacity, 5 Gbit/s lower order cross-conn ect capacity. Performs system communic ation and control. Supports the 20 Gbit/s packet switching function.
QinQ-based E-Line service E-LAN service based on IEEE 802.1d bridges E-LAN service based on IEEE 802.1q bridges E-LAN service based on IEEE 802.1ad bridges ETH PWE3 services ST M-1/STM-4/STM -16 services
Native Ethernet services Point-to-point transparently transmitted E-Line service VLAN-based E-Line service QinQ-based E-Line service E-LAN service based on IEEE 802.1d bridges E-LAN service based on IEEE 802.1q bridges E-LAN service based on IEEE 802.1ad bridges ETH PWE3 services
One Ethernet NM port/NM serial port (sharing one RJ45 port) One GE (SFP) optical port 1000BASE-LX/VX/ZX
Slots 7 and 8
TNM1 PCXG B
One Ethernet NM port/NM serial port (sharing one RJ45 port) One GE (SFP) optical port 1000BASE-LX/VX/ZX
Slots 7 and 8
Issue 01 (2011-06-30)
15
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
3 Product Architecture
Board Acron ym
Function
Service Type
Port Type
Valid Slot
Supports the 20 Gbit/s higher order cross-conn ect capacity, 5 Gbit/s lower order cross-conn ect capacity. Performs system communic ation and control.
VLAN-based E-Line service QinQ-based E-Line service E-LAN service based on IEEE 802.1d bridges E-LAN service based on IEEE 802.1q bridges E-LAN service based on IEEE 802.1ad bridges ETH PWE3 services
TNM1 MD1
CES E1 ATM/IMA E1
75/120-ohm E1 port
Slots 1 to 6
TNM1 EM6T
TNM1 EM6F
Transmits/R eceives FE/GE service signals and works with the packet switching unit to process the received FE/GE service signals.
Native Ethernet services Point-to-point transparently transmitted E-Line service VLAN-based E-Line service QinQ-based E-Line service E-LAN service based on IEEE 802.1d bridges E-LAN service based on IEEE 802.1q bridges E-LAN service based on IEEE 802.1ad bridges ETH PWE3 services Native Ethernet services
Four FE electrical Slots 1 ports: 10/100BASE-TX to 6 T wo GE electrical ports (compatible with FE electrical ports): 10/100/1000BASE-TX Four FE electrical ports: 10/100BASE-TX Provides two ports through the SFP module. The types of SFP module include 1000BASE-LX/VX/ZX . Slots 1 to 6
TNM1 EF8F
8xFE Ethernet
Transmits/R eceives FE
Slots 1 to 6
Issue 01 (2011-06-30)
16
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
3 Product Architecture
Board Acron ym
Function
Service Type
Port Type
Valid Slot
service signals and works with the packet switching unit to process the received FE service signals.
Point-to-point transparently transmitted E-Line service VLAN-based E-Line service QinQ-based E-Line service E-LAN service based on IEEE 802.1d bridges E-LAN service based on IEEE 802.1q bridges E-LAN service based on IEEE 802.1ad bridges ETH PWE3 services
SDH board
TNH2S 2xSTML1D 1 interface board TNH2S 2xSTML4D 4 interface board TNH2S 4xSTML1Q 1 interface board
Transmits/R eceives 2xSTM-1 optical signals. Transmits/R eceives 2xSTM-4 optical signals. Transmits/R eceives 4xSTM-1 optical signals. Transmits/R eceives E1/T1 signals. Transmits/R eceives E3/T3 signals. Provides the system with one orderwire
ST M-1 service
Slots 1 to 6
ST M-4 service
Slots 1 and 6
ST M-1 service
Slots 1 to 6
PDH board
TNH2S 42xE1/T P3D 1 tributary board TNH2P L3T 3xE3/T3 tributary board Auxiliar y interface
E1/T1 service
Slots 1 to 6
E3/T3 service
Slots 1 to 6
Auxiliar y board
TNM1 AUX
Slots 1 to 6
Issue 01 (2011-06-30)
17
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
3 Product Architecture
Board Acron ym
Function
Service Type
Port Type
Valid Slot
phone port, one synchronous data port, one asynchronou s data port, and one 6-input/2-ou tput external alarm port. Provides one N/A -48 V/-60 V DC power supply. Connects to 110-220 V AC power supplies. N/A
TND1P IU
Slots 91 and 92 Slots 2 and 4 Slots 4 and 6 (reco mme nded ) Slot 93
TNF1A PIU
Fan board
TNM1 FAN
Fan board
N/A
N/A
Ventilation Design
The case of the OptiX OSN 550 is densely covered with small air holes. Through these holes, air is let in from the left and out from the right by fans.
Ensure the smooth flow of air inside and around the equipment. Do not block the air inlet and air outlet of the subrack when cabling. Keep the top of subrack clean.
Issue 01 (2011-06-30)
18
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
3 Product Architecture
AIR OUT
AIR IN
Description of Labels
Table 3-3 lists the description of the labels on the chassis and the boards in the chassis. The actual labels may be different depending on the configurations of the chassis and boards. Table 3-3 Description of labels Label Label Name ESD protection label Description Indicates that the equipment is sensitive to static electricity. Indicates the grounding position of the chassis. Indicates that the fan leaves cannot be touched when the fan is rotating. Indicates that you must read the operation instructions before connecting a power cable.
Grounding label
Issue 01 (2011-06-30)
19
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
3 Product Architecture
Label
/QU ALIFICA TION CA RD
Description Indicates that the equipment is qualified. Indicates that the equipment contains certain hazardous substances specified in RoHS. The equipment needs to be recycled after the environment-frien dly use period of 50 years expires. Indicates the product name and certification.
HUAWEI
MADE NC HI A I N
RoHS label
50
DC power
AC power
The communication interfaces on the equipment are mainly Qx interfaces. For the description of the protocol stacks and messages on the Qx interfaces, see ITU-T G.773, ITU-T Q.811, and ITU-T Q.812. 3.3.3 Board Software
This section describes the software architecture of the OptiX OSN 550.
Issue 01 (2011-06-30)
20
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
3 Product Architecture
3.3.4 NE Software The NE software manages, monitors, and controls the running of boards in the NE. In addition, the NE software serves as the service unit for the communication between the NMS and boards. In this manner, the NMS can control and manage the NE. 3.3.5 NMS Software Like other optical transmission equipment, the OptiX OSN 550 is managed by the iManager series NMS.
High Level Communication Module Real-time multi-task operating system Network side Module Equipment Management Module Communication Module NE software Database Management Module
Board Software
Issue 01 (2011-06-30)
21
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
3 Product Architecture
A Qx interface mainly connects a mediation device (MD), Q adaptation (QA), or network element (NE) with an operations system (OS) through the local communication network (LCN). A QA interface is provided at the NE management layer, and an MD and OS are provided at the network management layer. As specified in the Recommendation, a Qx interface is developed in compliance with the Connectionless Network LayerService (CLNS1) based on T CP/IP. A Qx interface supports the remote access of NMS through a modem, and the IP layer uses the Serial Line Internet Protocol (SLIP) accordingly.
3.3.4 NE Software
The NE software manages, monitors, and controls the running of boards in the NE. In addition, the NE software serves as the service unit for the communication between the NMS and boards. In this manner, the NMS can control and manage the NE. In compliance with ITU-T M.3010, the NE software belongs to the element management layer in the telecommunications management network (TMN), and provides NE functions, some coordination functions, and operations system functions at the network element layer. The data communication function (DCF) provides communication functions between the NE and other components (including mediation devices, NMS, and other NEs). Real-time multi-task operating system The real-time multi-task operating system of the NE software is responsible for the management of public resources and supports applications. This system provides an application execution environment that is independent of the processor hardware, to separate applications from the processor. Communication and control module The Communication and control module is the interface module between the NE software and the board software. According to the corresponding communication protocol, the communication and control module achieves the communication between the NE software and the board software. In this manner, the information can be exchanged and the equipment can be maintained. On one hand, the communication and control module issues the maintenance operation commands of the NE software to the boards. On the other hand, it reports the status, alarms, and performance events of the boards to the NE software. Network side (NS) module The network side (NS) module is between the communication module and equipment management module. It converts the data format between the user operation side on the application layer and the NE equipment management layer, and provides security control for the NE layer. The NS module can be subdivided into three submodules in terms of function: Qx interface module, command line interface module, and security management module. Equipment management module The equipment management module (AM) is the kernel of the NE software. It implements NE management, and includes the Manager and the Agent. The Manager sends network management operation commands and receives event information. The Agent responds to the network management operation commands sent by the Manager, performs operations to managed objects, and reports events according to the status change of the managed objects. Communication module
Issue 01 (2011-06-30)
22
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
3 Product Architecture
This module fulfills the message communication function (MCF) of the functional blocks of the transmission network equipment. Through the hardware interface provided by the SCB board, the communication module transmits the OAM&P information and exchanges management information between the NMS and NEs, and between NEs themselves. The communication module consists of network communication module, serial communication module, and ECC communication module. Database management module The database management module is a principal component of the NE software. It consists of the data and the programs. The data, organized by database form, consists of the network database, alarm database, performance database, and equipment database. The program manages and accesses the data in the databases.
Issue 01 (2011-06-30)
23
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
4
Board
Issue 01 (2011-06-30)
24
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
4.2.3
CES Services
CES: By using the PWE3 technology, PWE3 packet headers are added to TDM traffic to create circuit emulation services (CES). PWE3 packet headers carry the frame format information, alarm information, signaling information, and synchronization and timing information of the TDM traffic. The encapsulated PW packets are transmitted over the MPLS tunnel on the PSN. After being decapsulated at the PW egress, the TDM circuit switched service traffic is re-created. On a packet switching network, the transmit and receive ends of a CES service maintain clock synchronization by means of adaptive clock recovery (ACR). 4.2.4 ATM/IMA Services This section provides the definition of ATM PWE3 and describes its purpose.
Service Model
Table 4-2 describes the point-to-point transparently transmitted E-Line service model. Table 4-2 Point-to-point transparently transmitted E-Line service model Service Model Model 1 Encapsulation Type Null (source) Null (sink) Service Direction UNI-UNI Traffic Flow PORT (source) PORT (sink) PORT (source) PORT (sink) Description The source port transparently transmits all the received Ethernet frames to the sink port. The source port processes the incoming Ethernet frames based on its TAG attribute, and then sends the processed Ethernet frames to the sink port. The sink port processes the Ethernet frames based on its TAG attribute, and then exports the processed Ethernet frames.
Model 2
UNI-UNI
In service model 2, ports process the received Ethernet frames according to their TAG attributes. Therefore, service model 2 is not a real transparent transmission model and is not recommended.
Issue 01 (2011-06-30)
25
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Typical Application
Figure 4-1 shows the typical application of service model 1. Figure 4-1 Typical application of service model 1
NE 1 Port 1 Service 1 Servic e 2 Port 2 E-Line E-Line Port 4 Port 3 Transmission Network Port 4 Port 3 NE 2 E-Line E-Line Port 2 Port 1 Service 1 Servic e 2
In service model 1, Ethernet service 1 and Ethernet service 2, which carry no VLAN ID or carry unknown VLAN IDs, are accessed to NE1 through port 1 and port 2 respectively. Port 1 and port 2 transparently transmit Ethernet service 1 and Ethernet service 2 to port 3 and port 4, respectively. Port 3 and port 4 then transmit Ethernet service 1 and Ethernet service 2 to NE2. Service processing on NE2 is the same as on NE1. In service model 2, Ethernet service 1 and Ethernet service 2, which carry no VLAN ID or carry unknown VLAN IDs, are accessed to NE1 through port 1 and port 2 respectively. Port 1 and Port 2 process the incoming packets based on their TAG attributes. Then, Port 1 and Port 2 send Ethernet service 1 and Ethernet service 2 to Port 3 and Port 4 respectively. Port 3 and Port 4 process the incoming packets based on their TAG attributes. Then, Port 3 and Port 4 send Ethernet service 1 and Ethernet service 2 to NE2. Service processing on NE2 is the same as on NE1.
Models of Services
Table 4-3 shows the models of VLAN-based E-Line services. Table 4-3 Models of VLAN-based E-Line services Type of Service VLAN-based E-Line services Encapsulation Mode of Port 802.1Q (source) 802.1Q (sink) Direction of Flow of Service Description of Service Service UNI-UNI The source port processes the incoming Ethernet frames based on its TAG attribute, and then sends the Ethernet frames with a specific VLAN NOTE ID to the sink port. The sink The VLAN ID of port processes the Ethernet the source and the frames based on its TAG VLAN ID of the attribute, and then exports the sink must be the processed Ethernet frames. same. PORT +VLAN (source) PORT +VLAN (sink)
Issue 01 (2011-06-30)
26
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Typical Applications
Figure 4-2 shows the typical application of VLAN-based E-Line services. Service 1 and Service 2 carry different VLAN IDs. Therefore, after the two Ethernet services are accessed to NE1 through Port 1 and Port 2 respectively, they can share the same transmission channel at Port 3. On NE1, Port 1 and Port 2 process the incoming packets based on their own TAG attributes. Then, Port 1 and Port 2 send Service 1 and Service 2 to Port 3. Port 3 processes all the outgoing packets based on its TAG attribute, and then sends Service 1 and Service 2 to NE2. Due to the different VLAN IDs, Service 1 and Service 2 can be transmitted through Port 3 at the same time. NE2 processes Service 1 and Service 2 in the same manner as NE1. Figure 4-2 Model of VLAN-based E-Line services
NE 1 Service 1 VLAN ID: 100 Service 2 VLAN ID: 200 Po rt 1
E-Line
NE 2 Port 1 Po rt 3 Transmission Ne twork Po rt 3 Service 1 VLAN ID: 100 Se rvice 2 VLAN I D: 200
E- Lin e
Port 2
e E- Lin
E-Lin e
Model of Service
Table 4-4 shows the models of QinQ-based E-Line services. Table 4-4 Models of QinQ-based E-Line Services Model of Service Model 1 Encapsulation Mode of a Port Null (source) QinQ (sink) Direction UNI-NNI Flow of Service Description of Service PORT (source) QinQ link (sink) The source port adds the S-VLAN tag that corresponds to the QinQ link to all the Ethernet frames, and then transmits the Ethernet frames to the sink port where the QinQ link is configured.
Issue 01 (2011-06-30)
27
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Direction UNI-NNI
Flow of Service Description of Service PORT (source) QinQ link (sink) The source port accesses only the Ethernet frames that carry C-VLAN tags. It adds the S-VLAN tag that corresponds to the QinQ link to all the Ethernet frames, and then transmits the Ethernet frames to the sink port where the QinQ link is configured. The source port adds the S-VLAN tag that corresponds to the QinQ link to all the Ethernet frames that carry specific C-VLAN tags, and then transmits the Ethernet frames to the sink port where the QinQ link is configured. The source port transmits the Ethernet frames that carry the S-VLAN tag to the sink port where the sink QinQ link is configured. The S-VLAN tag carried in the Ethernet frames corresponds to the source QinQ link. If the source and sink QinQ links correspond to different S-VLAN tags, the S-VLAN tags carried in the Ethernet frames are exchanged.
Model 3
UNI-NNI
Model 4
NNI-NNI
Typical Applications
Figure 4-3 shows the typical application of service model 1. Service 1 and Service 2 include tagged frames and untagged frames. Service 1 is accessed to NE1 through Port 1, and Service 2 is accessed to NE1 through Port 2. Port 1 adds the corresponding S-VLAN tag to Service 1, and Port 2 adds the corresponding S-VLAN tag to Service 2. Then, Service 1 and Service 2 are transmitted to Port 3. Port 3 transmits Service 1 and Service 2 to NE2. NE2 processes Service 1 and Service 2 in the same manner as NE1.
Issue 01 (2011-06-30)
28
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
NE 2 Transmission Network
E- Lin e
E -L in e
Port 3
Port 3
Figure 4-4 shows the typical application of service model 2. Service 1 and Service 2 carry different unknown C-VLAN tags. Service 1 is accessed to NE1 through Port 1, and Service 2 is accessed to NE1 through Port 2. Port 1 adds the corresponding S-VLAN tag to Service 1, and Port 2 adds the corresponding S-VLAN tag to Service 2. Then, Service 1 and Service 2 are transmitted to Port 3. Port 3 transmits Service 1 and Service 2 to NE2. NE2 processes Service 1 and Service 2 in the same manner as NE1. Figure 4-4 Typical application of service model 2
Strip S- VLAN Label C-V LAN C-V LAN Data( 1) Data(2) Add S-VLAN Label S-V LAN(300) S-V LAN(400) C-VLAN C-VLAN Data(1) Data(2)
E -Lin
E -Lin
Add S-V LAN Label S -VLAN(300) S -VLAN(400) C- VLA N C-VLA N Data(1) Data(2)
Figure 4-5 shows the typical application of service model 3. Service 1 and Service 2 carry different C-VLAN tags. Service 1 is accessed to NE1 through Port 1, and Service 2 is accessed to NE1 through Port 2. Port 1 adds the corresponding S-VLAN tag to Service 1, and Port 2 adds the corresponding S-VLAN tag to Service 2. Then, Service 1 and Service 2 are transmitted to Port 3. Port 3 transmits Service 1 and Service 2 to NE2. NE2 processes Service 1 and Service 2 in the same manner as NE1.
Issue 01 (2011-06-30)
29
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Port 2
Add S-VLAN Label S-VLAN(300) S-VLAN(400) C-VLAN( 100) C-VLAN(200) Data(1) Data(2)
Figure 4-6 shows the typical application of service model 4. Service 1 and Service 2 carry a same S-VLAN tag. Service 1 is accessed to NE1 through Port 1, and Service 2 is accessed to NE1 through Port 2. Port 1 changes the S-VLAN tag carried in Service 1 and Port 2 changes the S-VLAN tag carried in Service 2 so that the S-VLAN tags carried in Service 1 and Service 2 are different. Port 3 transmits Service 1 and Service 2 to NE2. NE2 processes Service 1 and Service 2 in the same manner as NE1. Figure 4-6 Typical application of service model 4
Switching S- VLAN Label S- VLA N( 100) S- VLA N( 100) Data( 1) Data(2) S -VLAN(300) S -VLAN(400) Data(1) Data(2)
E- Line
E -Lin e
E -Line
E-Lin e
Port 1 Service 1 S-VLAN ID: 100 Service 2 Port 2 S-VLAN ID: 100
S witching S-VLAN Label S-VLAN(300) S-VLAN(400) Data( 1) Data(2) S-V LA N(100) S-V LA N(100) Data(1) Data( 2)
Issue 01 (2011-06-30)
30
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Model of Service
Table 4-5 shows the model of E-LAN services based on the 802.1d bridge. Table 4-5 Model of E-LAN services based on the 802.1d bridge Type of Service E-LAN services based on the 802.1d bridge Encapsulation Mode of Port Null Tag Attribute Tag-Transparent Type of Logical Port PORT Learning Mode SVL Sub-Switchin g Domain No division of sub-switching domains
Typical Application
Figure 4-7 shows the typical application of the model of service. The transmission network needs to carry the A services accessed from NE2 and NE3. The two A services are converged at the convergence node NE1. The services need not to be isolated. Therefore, an 802.1d bridge is used at NE1 to groom services. Figure 4-7 Model of E-LAN services based on the 802.1d bridge
NE 2
Port 1 User A2
Port 1 User A1
Port 2
Port 1 User A3
Model of Service
Table 4-6 shows the models of E-LAN services based on 802.1q bridge.
Issue 01 (2011-06-30)
31
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Table 4-6 Model of E-LAN services based on 802.1q bridge Type of Service E-LAN services based on 802.1q bridge Encapsulation Mode of Port 802.1q TAG Attribute Type of Logical Port C-Awared PORT +VLAN Learning Mode IVL Sub-Switchin g Domain Sub-switching domains are divided based on VLANs.
Typical Applications
Figure 4-8 shows the typical application of the model of E-LAN services based on 802.1q bridge. The transmission network needs to carry G and H services accessed from NE2 and NE3. Both types of services are converged on NE1. G and H services adopt different VLAN planning. Therefore, 802.1q bridge is used on NEs and sub-switching domains are divided based on VLANs, differentiating and separating the two types of services. Figure 4-8 Model of E-LAN services based on 802.1q bridge
NE 2 VLAN 100 Port 1 User G 2
NE 1
VLAN 100
Port 1
User G 1
VLAN 200 P ort 2 Us er H1 P ort 4 Transm i ss ion Network 802.1q bri dge
P ort 3
802.1q bridge
You can configure VLAN-Based E-Line Services on NE2 and NE3 for service access.
Issue 01 (2011-06-30)
32
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Model of Service
Table 4-7 shows the models of E-LAN services based on 802.1ad bridge. Table 4-7 Models of E-LAN services based on 802.1ad bridge Type of Services E-LAN services based on 802.1ad bridge Encapsulation Mode of Port Tag Attribute Type of Logical Port PORT (The encapsulation mode of the UNI port is Null.) PORT or PORT +C-VLAN (The encapsulation mode of the UNI port is 802.1q.) Learning Mode IVL Sub-Switchin g Domain Sub-switching domains are divided based on S-VLAN tags.
a: When the encapsulation mode of port is 802.1q, the tag attribute must be Tag Aware.
Typical Applications
Figure 4-9 shows the typical application of the model of service. The transmission network needs to carry G and H services accessed from NE2 and NE3. The two types of services are converged on NE1. Since G and H services have a same C-VLAN tag, you need to add different S-VLAN tags to G and H services for service isolation.
Issue 01 (2011-06-30)
33
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
NE 2 SVLAN 300 Port 1 User G 2 CVLAN 100 SVLA N 400 T ransm i ss ion Network Port 3 802.1ad bri dge SVLAN 400 Port 2 User H1 CVLAN 100 P or t 4 Tr ans m is si on Network SVLA N 400 P ort 2 Us er H2 CVLAN 100
Por t 3
NE 1
SVLAN 300
Port 1
User G 1 CVLAN 100
NE 3 SVLAN 300 P ort 1 User G 3 CVLAN 100 P ort 2 Us er H3 CVLAN 100 802.1ad bri dge
802.1ad bridge
Por t 3
You can configure QinQ-Based E-Line Services on NE2 and NE3 for service access.
Issue 01 (2011-06-30)
34
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
The E-Line services of different companies are carried by different PWs and then to the same port on the network side. In this manner, the port resources on the network side are saved and the bandwidth utilization is increased. In the uplink direction of the user side, layered QoS configuration can be performed for data packets. Figure 4-10 E-Line services carried by PWs
NE1
Company A
PSN
NE2
Company A
Company B Company B
City 1
Tunnel PW
Emulation Mode
The OptiX NG-SDH series equipment supports two types of CES services: structure-aware TDM circuit emulation service over packet switched network (CESoPSN) CES and structure-agnostic TDM over packet (SAToP) CES. In the case of CESoPSN CES: The equipment senses the frame format, frame alignment mode, and timeslot information in the TDM circuit. The equipment processes the overheads and extracts the payloads in TDM frames. Then, the equipment loads timeslots to the packet payload in a certain sequence. As a result, the services in each timeslot are fixed and visible in packets. In the case of SAToP CES: The equipment does not sense any format in the TDM signal. Instead, it considers TDM signals as bit flows at a constant rate, and therefore the entire bandwidth of TDM signals is emulated.
Issue 01 (2011-06-30)
35
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Service Type
CES services are classified into UNI-UNI CES services and UNI-UNI CES services by service implementation point. UNI-UNI CES services As shown in Figure 4-11, a single OptiX OSN NE completes access of TDM services. Figure 4-11 UNI-UNI CES services
PSN
BSC
UNI-NNI CES services As shown in Figure 4-12, the OptiX OSN NEs set UNI-NNI CES services. In the case of a UNI-NNI CES service, the OptiX OSN NEs access customer TDM services through E1 ports; CES PWs are created between the OptiX OSN NEs to emulate end-to-end TDM services. Figure 4-12 UNI-NNI CES services
NE NodeB1
NE PSN BSC
Issue 01 (2011-06-30)
36
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Definition
The ATM PWE3 technology emulates the basic behaviors and characteristics of ATM services on a packet switched network (PSN) by using the PWE3 mechanism, so that the emulated ATM services can be transmitted on a PSN.
Purpose
Aided by the ATM PWE3 technology, conventional ATM networks can be connected by a PSN. Specifically, ATM PWE3 allows transmitting conventional ATM services over a PSN by emulating the ATM services. The networking type of ATM PWE3 can be one-to-one or N-to-one depending on the encapsulation type of ATM PWE3 packets. It is obvious that ATM PWE3 helps to transmit ATM services over the PSN, without adding ATM equipment or changing the configuration of the ATM CE equipment. Figure 4-13 Typical application of ATM PWE3 (in the one-to-one encapsulation mode)
PSN PW AC CE1 PE1 AC LSP PE2 CE2
ATM PWE3 1-to-1 ATM PWE3 service 1-to-1 ATM PWE3 service
NodeB
RNC
Issue 01 (2011-06-30)
37
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Figure 4-14 Typical application of ATM PWE3 (in the N-to-one encapsulation mode)
ATM PWE3 N-to-1 ATM PWE3 service N-to-1 ATM PWE3 service
CE3
NodeB
RNC
Issue 01 (2011-06-30)
38
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Definition
MPLS APS is a function that protects MPLS tunnels based on the APS protocol. With this function, when the working tunnel is faulty, the service can be switched to the preconfigured protection tunnel. The MPLS APS function supported by the OptiX OSN 550 has the following features: The MPLS APS provides end-to-end protection for tunnels. The working tunnel and protection tunnel have the same ingress and egress nodes. The protection tunnel in the MPLS APS protection pair does not carry extra traffic. In MPLS APS, the MPLS OAM mechanism is used to detect faults in tunnels, and the ingress and egress nodes exchange APS protocol packets to achieve protection switching.
Purpose
MPLS APS improves reliability for service transmission in tunnels. As shown in Figure 4-15, when the MPLS OAM mechanism detects a fault in the working tunnel, the service is switched to the protection tunnel for transmission.
Issue 01 (2011-06-30)
39
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Protectio n Tunnel
Protection Tunnel
Transit Service
4.3.2 PW APS
This section provides the definition of PW APS and describes its purpose.
Definition
PW APS is a function that protects PWs based on the APS protocol. With this function, when the working PW is faulty, the service can be switched to the preconfigured protection PW. The PW APS function supported by the OptiX OSN 550 has the following features: The PW APS function provides end-to-end protection for PWs. The working PW and protection PW are carried in different tunnels but have the same local and remote PEs. The protection PW in the PW APS protection pair does not carry extra traffic.
Issue 01 (2011-06-30)
40
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
In PW APS, the PW OAM mechanism is used to detect faults in PWs, and the PEs exchange APS protocol packets to achieve protection switching.
Purpose
PW APS improves reliability for service transmission in PWs. As shown in Figure 4-16, when the PW OAM mechanism detects a fault in the working PW, the service is switched to the protection PW for transmission. Figure 4-16 Application example of PW APS
PE2
Protection PW
Protection P W
PE 3 Service
4.3.3 LPT
This section provides the definition of LPT and describes its purpose.
Issue 01 (2011-06-30)
41
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Definition
Link State Pass Through (LPT) detects a fault that occurs at a service access node or on a service network, and then instructs the equipment at both ends of a service network to immediately start a backup network for communication. LPT ensures proper transmission of important data. As shown in Figure 4-17, LPT-enabled NE1 and NE2 will disconnect their access links from router A and router B if access link 1, access link 2, or the service network becomes faulty. As a result, router A and router B will immediately detect the link fault between them, and switch to backup networks for communication. Figure 4-17 Typical application of LPT
Backup network
Service network NE1 Router A Access link 1 Working link Protection link NE2 Access link 2 Router B
Purpose
With the LPT function enabled, access equipment will immediately detect link faults and switch to backup networks timely.
4.3.4 LAG
Link aggregation allows multiple links that are attached to the same equipment to be aggregated together to form a LAG so that the bandwidth increases and the reliability of the links is improved. The aggregated links can be considered as a single logical link. A LAG aggregates multiple physical links to form a logical link that is at a higher rate to transmit data. Link aggregation functions between adjacent equipment. Therefore, link aggregation is not related to the architecture of the entire network. Link aggregation is also called port aggregation because links correspond to ports one to one on an Ethernet network. As shown in Figure 4-18, the LAG provides the following functions: Increased bandwidth A LAG provides users with a cost-effective method for increasing the link bandwidth. Users obtain data links with higher bandwidths by combining multiple physical links into one logical link without upgrading the existing equipment. The bandwidth of the logical
Issue 01 (2011-06-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd. 42
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
link is equal to the sum of the bandwidths of the physical links. The aggregation module distributes the traffic to different links by using the load sharing algorithm, therefore providing the load sharing function for links. Increased availability The links in a LAG dynamically back up each other. When a link fails, the other links in the LAG quickly take over. The process in which link aggregation starts the backup link is associated only with the links in the same LAG, and the links not in the LAG are not involved. Figure 4-18 Link aggregation group
Li nk 1 Li nk 2 E th ernet p ackets Li nk 3 E th ernet p ackets
LAG
4.4 Maintenance
This section describes the maintenance functions and features including MPLS OAM, ETH-OAM, ATM OAM, and RMON in the packet domain. 4.4.1 MPLS OAM The MPLS OAM mechanism supported by the equipment includes tunnel OAM and PW OAM. Tunnel OAM operates at the tunnel layer, and PW OAM operates at the PW layer. Tunnel OAM and PW OAM both provide the complete fault detection and locating mechanism. 4.4.2 ETH-OAM ETH-OAM enhances Ethernet Layer 2 maintenance functions and it strongly supports service continuity verification, service deployment commissioning, and network fault locating. 4.4.3 ATM OAM This section provides the definition of ATM OAM and describes its purpose. 4.4.4 RMON
By using the remote monitoring (RMON), you can transmit network monitoring data between different network sections. 4.4.5 PRBS Certain boards provide the PRBS functional module, which is used for testing and maintaining the network. You can determine whether the working path on a tributary port, in the line direction, or in the cross-connect direction is normal, depending on whether bit errors are detected in a PRBS test. 4.4.6 CES Alarm Transmission
Issue 01 (2011-06-30)
43
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
The OptiX OSN 550 uses the L/M and R fields in the control word to transparently transmit alarms.
Tunnel OAM
Description The tunnel OAM mechanism helps to effectively detect, identify, and locate internal defects at the tunnel layer of an MPLS network. The equipment triggers the protection switching based on the OAM detection status. Therefore, quick fault detection and service protection can be achieved. Objectives and benefits As a key bearer technology for the scalable next generation network (NGN), MPLS provides multi-service capabilities with ensured QoS. In addition, MPLS introduces a unique network layer (tunnel), which may cause some faults. Therefore, an MPLS network must have the OAM capability. By providing a tunnel OAM mechanism independent of any upper layer or lower layer, the tunnel OAM supports the following features: Provides query-on-demand and consecutive detections so that at any moment you can learn whether the monitored LSP has defects. Detects, analyzes, and locates any defect that occurs, and notifies the NMS of the relevant information. Triggers a protection switching immediately after a defect or fault occurs on a link. Monitors the performance events indicating packet loss ratio, delay, and jitter in real time and reports them to the NMS.
PW OAM
Description The PW OAM mechanism helps to effectively detect, identify, and locate internal defects at the PW layer of a network. The equipment triggers the protection switching based on the OAM detection status. Therefore, quick fault detection and service protection can be achieved. Objectives and benefits The equipment performs PW encapsulation on service packets, and then transmits the service packets over tunnels. The network consists of two layers: tunnel and PW. Tunnels use tunnel OAM for maintenance and management, and PWs use PW OAM for maintenance and management. Currently, the equipment can detect the connectivity of a certain PW through ping packets, and then reports the result to the NMS.
4.4.2 ETH-OAM
ETH-OAM enhances Ethernet Layer 2 maintenance functions and it strongly supports service continuity verification, service deployment commissioning, and network fault locating.
Issue 01 (2011-06-30)
44
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Definition
With the continuous development of the Ethernet, especially when LANs evolve to WANs, operators pay more attention to equipment maintainability. Solutions to operations, administration and maintenance (OAM) in the transmission network are required urgently. Therefore, ETH-OAM is developed. ITU-T and IEEE have researches on ETH-OAM. Currently, Huawei Ethernet service processing boards have realized the ETH-OAM function, which complies with IEEE 802.1ag and IEEE 802.3ah. Wherein, IEEE 802.1ag define Ethernet service OAM standards, and IEEE 802.3ah defines Ethernet port OAM standards. As shown in Figure 4-19, the combination of IEEE 802.1ag and IEEE 802.3ah provides a complete Ethernet OAM solution. Figure 4-19 Application of IEEE 802.1ag and IEEE 802.3ah
IEEE 8 02.3ah IEEE 80 2.1ag I EEE 8 02.3ah
P Router 2
CE4
Ethernet service OAM focuses on the maintenance of end-to-end Ethernet links. Based on services, Ethernet service OAM implements end-to-end detection in the unit of "maintenance domain" and performs segmental management on each network segment that is involved in the same service on a network. Ethernet port OAM focuses on the maintenance of point-to-point Ethernet link between two directly-connected devices in Ethernet in the first mile (EFM). Ethernet port OAM does not focus on a specific service. It maintains the point-to-point Ethernet link by performing OAM auto-discovery, link performance monitoring, fault check, remote loopback, and selfloop check.
Purpose
Based on the MAC layer, the ETH-OAM protocol performs OAM operations for the Ethernet by transmitting OAM packets. This protocol is irrelevant to the transmission medium. The OAM packets are processed only at the MAC layer, having no impact on the other layers of the Ethernet. In addition, as a low-rate protocol, the ETH-OAM protocol occupies low bandwidths. Therefore, this protocol does not affect services carried on links. A comparison of ETH-OAM and existing OAM and fault locating methods is provided as follows:
Issue 01 (2011-06-30)
45
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
When a loopback is performed at a port, all packets on the port are looped back. Therefore, the loopback method cannot be used if only a specific service needs to be looped back. ETH-OAM can detect hardware faults. ETH-OAM can detect and locate faults automatically.
Definition
ATM OAM is used for detecting and locating ATM faults, and monitoring ATM performance. In this document, ATM OAM refers to OAM only at the ATM layer and implements various OAM functions by means of specific ATM OAM cells.
Purpose
ATM OAM provides segment-based ATM OAM between the CE and the PE and end-to-end-based ATM OAM between CEs. As shown in Figure 4-20, ATM OAM cells are transmitted and detected between the CE and the PE, or between the CEs to monitor the ATM link. Figure 4-20 Typical application of ATM OAM
CE1 (NodeB)
PE1
P E2
CE2 (RNC)
4.4.4 RMON
By using the remote monitoring (RMON), you can transmit network monitoring data between different network sections. Currently, the management of the Ethernet performance for transmission products is relevantly simple. In the case of the management of Ethernet ports, the management of the performance data of the ports is required. What's more, as the network is becoming complex, a method for managing network sections is required. Thus, the RMON emerges and the RMON should have the following features:
Issue 01 (2011-06-30)
46
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
All statistics data is saved at the agent and the out-of-service operation on the manager is supported. History data is saved for the fault diagnosis. Errors are detected and reported. Detailed data is provided. Multiple management stations are supported. Based on the preceding purposes, the RMON defines a serial of statistic formats and functions to realize the data exchange between the control stations and detection stations that complies with the RMON standards. To meet the requirements of different networks, the RMON provides flexible detection modes and control mechanism. What's more, the RMON provides error diagnosis, planning and information receiving of the performance events of the entire network.
4.4.5 PRBS
Certain boards provide the PRBS functional module, which is used for testing and maintaining the network. You can determine whether the working path on a tributary port, in the line direction, or in the cross-connect direction is normal, depending on whether bit errors are detected in a PRBS test. In the case of E1 services, T1 services or T3 services, the PRBS15 is transmitted. The PRBS function of the board is available in two types: lower-order PRBS function and higher-order PRBS function. Currently, the OptiX OSN equipment supports only the lower-order PRBS function. In the case of the lower-order PRBS function, the PRBS module is integrated with the tributary board. An NE that provides the PRBS function can be used as a simple instrument. You can determine whether a service path is faulty and can determine the location of the fault on fibers or relevant boards between the faulty NEs, depending on the bit errors detected on the NE. The PRBS function module can analyze the local NE and the entire network. Therefore, you can perform a test without using a real instrument during the deployment or fault locating.
Issue 01 (2011-06-30)
47
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
PSN
AC1 NodeB PW LSP AC2
PE1
PE2
RNC
The service alarms on the AC side are transparently transmitted through the PSN as follows: When receiving TDM signals carrying AIS/RAI alarms from AC1 side, PE1 uses the L or M field in the control word to respectively transmit AIS and RAI alarms to PE2. Then, PE2 inserts AIS/RAI alarms into AC2 based on the received L or M field.
The SAToP encapsulation mode does not support the M field, and therefore cannot transparently transmit the RAI alarm.
The fault information on the AC link or port is transmitted through the PSN as follows: When detecting an AC link fault or E1 port fault in AC1, PE1 uses the L or M field in the control word to transmit the fault information to PE2. Then, PE2 inserts alarms into AC2 based on the received L or M fields.
CES Alarm Transparent Transmission from the NNI Side to the AC Side
Figure 4-22 shows the CES alarm transparent transmission from the NNI side to the AC side. Figure 4-22 CES alarm transparent transmission from the NNI side to the AC side
PSN
AC1 NodeB PW LSP AC2
PE1
PE2
RNC
When detecting that packet loss ratio continuously beyond the preset threshold, PE2 inserts the AIS alarm into AC2, and uses the R field in the control word to transmit the information to PE1. Then, PE1 reports the RDI alarm based on the R field, and inserts the RAI alarm into the AC1 side.
Issue 01 (2011-06-30)
48
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
4.5 Synchronization
This section describes synchronization features including synchronous Ethernet clock, and CES ACR in the packet domain. 4.5.1 Synchronous Ethernet Clock
The synchronous Ethernet clock is a technology that extracts the clock from the serial bit stream on the Ethernet line, and transmits data through the extracted clock to realize the transfer of clocks. 4.5.2 CES ACR
This section provides the definition of CES ACR and describes its purpose.
Definition
The synchronous Ethernet clock is a technology of frequency synchronization over the physical layer. The system directly extracts the clock signal from the serial bit stream on the Ethernet line, and transmits the data to each board by using the clock signal to realize the transfer of clock information.
Purpose
As the network is increasingly based on the Ethernet transfer technology, the large-scale network at the carrier-class level requires the synchronous Ethernet to transmit the clock and introduces the networkwide synchronous timing transmission idea of the SDH system to the Ethernet design. Therefore, the clock signal can be transmitted from the core to the edge by using the Ethernet physical layer, to provide ensured timing for various real-time services.
Definition
CES ACR is a function that uses the adaptive clock recovery (ACR) technology to recover clock synchronization information carried by CES packets. In the standard CES ACR solution, the source end (Master) considers the local clock as the timestamp in the Real-time Transport Protocol (R TP) packet header and encapsulates it in the CES packet; the sink end (Slave) recovers the clock according to the timestamp in the packet. In this manner, signal impairment during the transmission is prevented. The OptiX OSN 550 adopts the enhanced timestamp clock solution. That is, clocks can be recovered based on SN in CES packets rather than timestamps in R packet headers. See TP Figure 4-23.
Issue 01 (2011-06-30)
49
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Master
SN
E1
Processing
CE S
CES
Processing
E1
PSN
E1 CES E1
BTS
P E1
PE 2
BSC
Purpose
In the packet domain, CES ACR is mainly used to transparently transmit E1 clocks in the PSN. For details, see CES ACR Clock Transparent Transmission Solution.
Issue 01 (2011-06-30)
50
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
5
Board PCXLX PCXX PCXLG PCXGA PCXGB
Issue 01 (2011-06-30)
51
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
The SNCP scheme, which requires one working subnet and one protection subnet, is to select one service from the dually transmitted services. 5.3.2 Ring MSP
Ring MSP uses the multiplex section overhead (MSOH) bytes K1 and K2 to implement automatic protection switching of services. 5.3.3 Linear MSP The linear MSP uses the K1 and K2 bytes in the multiplex section overhead to realize automatic protection switching. The OptiX OSN equipment supports 1+1 and 1:N linear MSP.
5.3.1 SNCP
The SNCP scheme, which requires one working subnet and one protection subnet, is to select one service from the dually transmitted services. The SNCP scheme, which requires one working subnet and one protection subnet, is to select one service from the dually transmitted services. If the working subnet fails to be connected or if its performance fails to meet certain requirements, the connection of the protection subnet takes over. Figure 5-1 shows the application of the SNCP.
Issue 01 (2011-06-30)
52
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
NE A Pro tection SNC Protection switchin g Working SNC Sou rce end
NE B
Sin k e nd
NE B
Issue 01 (2011-06-30)
53
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
West NE B East
East NE D West
West
East
Protection switching
West
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
the working channel of the faulty fiber to the protection channel of the reverse directional fiber for transmission. Figure 5-3 shows the application of the two-fiber bidirectional ring MSP. After the protection switching, the signal flow of the services from NE A to NE C is NE ANE DNE CNE BNE C, and the signal flow of the services from NE C to NE A is NE CNE BNE CNE DNE A. Figure 5-3 Two-fiber bidirectional ring MSP
West
East
Protection switching
West
Issue 01 (2011-06-30)
55
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
the service is received from the protection channel. Figure 5-4 shows the application of the 1+1 linear MSP. Figure 5-4 1+1 linear MSP
NE A
Working channel
NE B
Protection channel
Protection channel
No extra traffic can be configured in the protection channel in a 1+1 linear MSP group.
Issue 01 (2011-06-30)
56
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Protection s witching NE A Common service 1 ... Working channel N Common service N Protection channel Extra traffic Extra traffic Common service N ... Working channel 1 NE B Common servic e 1
Purpose
The LMSP scheme uses the MSOH bytes K1 and K2 to implement automatic protection switching once the working path fails, and therefore to protect services.
5.4 Maintenance
Certain boards provide the PRBS functional module, which is used for testing and maintaining the network. You can determine whether the working path on a tributary port, in the line direction, or in the cross-connect direction is normal, depending on whether bit errors are detected in a PRBS test. In the case of E1 services, T1 services or T3 services, the PRBS15 is transmitted. The PRBS function of the board is available in two types: lower-order PRBS function and higher-order PRBS function. Currently, the OptiX OSN equipment supports only the lower-order PRBS function. In the case of the lower-order PRBS function, the PRBS module is integrated with the tributary board. An NE that provides the PRBS function can be used as a simple instrument. You can determine whether a service path is faulty and can determine the location of the fault on fibers or relevant boards between the faulty NEs, depending on the bit errors detected on the NE. The PRBS function module can analyze the local NE and the entire network. Therefore, you can perform a test without using a real instrument during the deployment or fault locating.
Issue 01 (2011-06-30)
57
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
5.5 Synchronization
Clock synchronization on the entire network helps to transmit services normally.
Definition
Clock: The electronic circuit in a computer that generates a steady stream of timing pulses.
Purpose
Clock synchronization ensures that all the digital devices on a communications network work at the same nominal frequency, and therefore minimizes the impacts of slips, burst bit errors, phase jumps, jitters, and wanders on digital communications systems. Clock synchronization also minimizes pointer justifications on SDH devices. Therefore, clock synchronization is the precondition and basis for the normal operation of a network.
Issue 01 (2011-06-30)
58
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Ring
Tangent rings
Issue 01 (2011-06-30)
59
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Legend
FE TDM E1
FE NE 1 TDM E1
NE 2 NE 3 FE Node B NE 4
A TM/IMA E1
Packet domain
TDM domain
No de B
BTS
Issue 01 (2011-06-30)
60
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
E1
Packet domain
TDM domain
Node B
BTS
Issue 01 (2011-06-30)
61
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
FE
NE 5
ATM/IMA E 1 GE NE 1 TDM E1 GE NE 4 NE 2
FE GE
NE 3 GE
FE
TDM E 1
Nod e B
BTS
NE 3 PCXGB NE6 EM 6F FE
PCXGB
Node B
BTS
Issue 01 (2011-06-30)
62
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
TDM E1
NE1
TDM E1
TDM E1
BTS
Issue 01 (2011-06-30)
63
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
NE6
E1 E1 NE6
SP3D
NE2
PCXLG PCXLG
NE4
PCXLG PCXLG SP3D
NE6
E1
E1 NE3
PCXLG PCXLG
NE6
SP3D
E1 BTS
Issue 01 (2011-06-30)
64
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
7 Security Management
Security Management
Issue 01 (2011-06-30)
65
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
7 Security Management
By default, five user groups are available with authorities in an ascending order: monitor group, operator group, maintenance personnel group, administrator group, and super administrator group. You can change the group to which a user belongs.
ACL Protocol
The ACL rules are configured to filter the received IP packets. This controls the data traffic on the network and protects against malicious attacks. You can set basic ACL rules or advanced ACL rules, based on the required system security level. For an NE that requires a low security level, you can configure the basic ACL rules so that the NE checks only the source addresses of received IP packets. For an NE that requires a high security level, you can configure the advanced ACL rules. In this case, the NE checks the source addresses, sink addresses, source ports, sink ports, and protocol types of the received IP packets. If both the advanced and basic ACL rules are configured, the NE uses only the advanced ACL rules to check the received IP packets. In addition, the ACL rules support the following operations: Queries of the ACL rules Modification of the ACL rules Deletion of the ACL rules
SSL Protocol
The SSL protocol is used to protect the integrity and security of data.
RADIUS Protocol
RADIUS provides a complete network security solution. After the RADIUS server verifies that the user name and password of a user are valid, the server allows a certain authority for the user, and provides services to the user. The RADIUS server of the carrier manages all the user accounts and user attributes of the OptiX OSN 550. To log in to the OptiX OSN 550, you must apply for a user account to the carrier. When you try to log in to the OptiX OSN 550, the RADIUS server verifies the user name and password that you have entered. If the verification fails, a login error is reported. The OptiX OSN 550 supports the shielding function when being connected to the network port management device. That is, when being connected to the network port on an OptiX
Issue 01 (2011-06-30)
66
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
7 Security Management
OSN 550, the network port management device manages only the connected OptiX OSN 550, and cannot access the other devices that are connected to the OptiX OSN 550 through the ECCs. With this function, even if an OptiX OSN 550 NE in the insecure domain is accessed illegally, the NEs that are connected to the OptiX OSN 550 will not be illegally operated.
Syslog Management
The Syslog service is used for the security management of NEs. Different information is transmitted to the Syslog server in a format compliant with the Syslog protocol so that the maintenance personnel can monitor NEs easily. The OptiX OSN 550 supports the following functions related to the Syslog protocol: Enabling and disabling the Syslog protocol. Setting the transmission mode of the Syslog protocol to UDP (by default) or T CP. Adding or deleting Syslog servers. Configuration of multiple Syslog servers and transmission of logs to multiple servers at the same time. Reporting relevant alarms when the Syslog server fails to communicate with NEs. Figure 7-1 illustrates the log transmission of the the Syslog protocol on a network. To ensure the security of system logs, at least two Syslog servers are required on a transmission network. NEs communicate with Syslog servers by running the IP protocol. NEs communicates with each other in many modes, such as ECC and IP over DCC.
Issue 01 (2011-06-30)
67
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
7 Security Management
NMS
NE C (clie nt)
Syslo g Server B
Syslog Serve r A
NE D
A Syslog server is a work station or server that stores the system logs of all NEs on a network. Forwarding gateway NEs receive system logs from other NEs, and then forward these system logs to Syslog servers. For example, NE A and NE C in Figure 7-1.
When NEs communicate in IP mode, each NE can directly communicate with two different Syslog servers by running the IP protocol. Hence, you need to configure the IP addresses and port numbers of the Syslog servers on an NE. The NE transmits the system log to two Syslog servers by using the automatic routing function of the IP protocol. You need not configure any forwarding gateway NE. When NEs communicate in ECC mode, the NEs that are not directly connected to Syslog servers cannot communicate with Syslog servers. The logs of these NEs need to be transmitted to the gateway NEs that can communicate with Syslog servers directly. Then, the gateway NEs forward the logs to Syslog servers. Therefore, you need to configure forwarding gateway NEs. For example, you can configure NE A as the forwarding NE of NE D.
Issue 01 (2011-06-30)
68
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
8
8.1 DCN
Item Purpose and Benefit
Reliable network management ensures proper running of a network, and therefore transmission of network management data becomes very critical. The data communication network (DCN) is a network management data communication channel, with which users can remotely manage and maintain NEs. Table 8-1 lists the DCN solutions that the OptiX OSN 550 supports. Table 8-1 DCN solutions that the OptiX OSN 550 supports Inband DCN NM information is transmitted on the service channels provided by managed equipment. Therefore, no other equipment and DCN are required. This reduces operating cost. Flexible networking: NM information is encapsulated into Ethernet frames and carries a fixed VLAN ID to get separated from the service data. The NM information is transmitted with services on service channels. Configurable VLAN priorities for inband DCN packets Outband DCN NM information is transmitted on non-service channels. High reliability: Outband DCN uses dedicated maintenance channels. Therefore, the NMC can construct a DCN network with managed equipment in various ways, such as E1 private lines and Ethernet; in addition, you can obtain NM information in time even when faults occur on service channels. HW ECC IP OSI TDM network
Feature
Networking Technology
Application Scenario
Packet network
Issue 01 (2011-06-30)
69
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Outband DCN Channel type: D1-D3 and D4-D12 Running mode: Mode 1: 32 channels of D1-D3 bytes Mode 2: 12 channels of D1-D3 bytes or 6 channels of D4-D12 bytes
Provides audible and visual alarms in case of emergency, assisting the network administrator in taking prompt measures. Provides running status indicators and alarm indicators on each board, assisting the administrator in locating and handling faults promptly. Provides the alarm input and output function, therefore facilitating the collection of equipment alarms. Dynamically monitors the equipment operation and alarm status of all stations on the NMS. Detects alarms and performance of a standby system control board. As for the 15-minute monitoring period, the equipment can store sixteen 15-minute history performance, that is, four hours of 15-minute history performance. As for the 24-hour monitoring period, the equipment can store 6x24-hour history performance, that is, six days of history performance. Monitors the data on a transmission network located in different network segments. RMON is a supplement to simple Ethernet performance management means, and can be used for a wide range of networks.
RMON
Issue 01 (2011-06-30)
70
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Applicati Function on Scenario Upgrade and loading of board software and NE software
Description
Supports in-service upgrades and loading of board software and NE software. Supports remote loading of board software and field programmable gate array (FPGA). Supports error-loading-proof and resumable loading. Measures the input voltage and detects the undervoltage and overvoltage states. Supports the fiber auto-discovery function on the NMS.
Voltage check Automatic search for optical fibers Queries of port impedance Queries of information about optical modules Monitoring the outdoor cabinet Power consumption control
Supports the query of port impedance on the NMS. Allows information about optical modules to be queried on the NMS, including the single-mode/multi-mode, rate level, vendor, production date, and wavelength. Monitors the outdoor cabinet by means of the monitoring port on the AUX board. Computes and reports the system power consumption. Monitors the total system power consumption, and reports alarms if the total system power consumption is about to exceed or is higher than the rated NE power consumption. Detects and monitors the connectivity and performance of service trails by using outband packets. During the process, services are not affected. Complies with IEEE 802.1ag and IEEE 802.3ah. Detects and locates ATM faults, and monitors ATM performance. Detects and locates faults within an MPLS network, and works with MPLS APS to protect services. MPLS OAM mechanisms include tunnel OAM and PW OAM. Tunnel OAM operates at the tunnel layer, and PW OAM operates at the PW layer.
OAM
ETH OAM
Fault locating
Provides the one-click data collection function to collect fault data, which shortens data collection time before service recovery. Users can collect fault data selectively, and can stop a collection process manually. Service boards support inloops and outloops on ports, which facilitates fault locating.
Loopback
Issue 01 (2011-06-30)
71
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Description
If the equipment becomes faulty, the maintenance personnel can use a public telephone network to remotely maintain the OptiX OSN 550 systems. An NE enabled with the PRBS function can be used as a simple instrument that transmits and receives unframed services in order to analyze whether service paths are faulty. An NE enabled with the PRBS function can be used to analyze itself or the entire network. The PRBS function is a substitute for a test instrument during a deployment or fault localization. The system control, switching, and timing boards and service boards support warm and cold resets. Warm resets do not affect services. The system control, switching, and timing boards, service boards, fan boards, and power supply boards support hot swap. Pluggable optical modules can be hot-swapped. Service cables and auxiliary cables can be hot-swapped.
Issue 01 (2011-06-30)
72
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Table 8-3 Upgrade methods available for the OptiX OSN 550 Upgrade Method Definition Package Loading With a software package description file, the software package functions as a logical package of the required software. This logical package can be uploaded to upgrade the entire NE. Package Diffusion With a software package description file, the software package functions as a logical package of the required software. The logical package is diffused and almost synchronously loaded to all NEs on a network. This upgrade method is more efficient. More than one NE needs to be upgraded. The system control board and other boards must support package loading. There is a CF card on the system control board. All the boards on an NE can be upgraded on a unified GUI. There is no need to care about which board to upgrade or which files to update. The software package is diffused. Network load and network bandwidth are both shared. Versions of V100R003C00 and later support this upgrade method. Hot Patch Loading During hot patch loading, new software codes substitute for running software codes, which do not interrupt services but rectify a software defect or implement a new requirement. These new software codes are codes in a hot patch. Services are not interrupted during the upgrade.
Application Scenario
One NE needs to be upgraded. The system control board and other boards must support package loading. There is a CF card on the system control board. All the boards on an NE can be upgraded on a unified GUI. There is no need to care about which board to upgrade or which files to update.
Characteristic
Services are not interrupted during the upgrade. Hot patches decrease the number of product versions, therefore avoiding frequent version upgrades. Hot patches can be loaded remotely. Version rollback is supported after a hot patch is loaded, reducing upgrade risks. Versions of V100R005C01 and later support this upgrade method.
Applicable Version
Issue 01 (2011-06-30)
73
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Issue 01 (2011-06-30)
74
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
9
9.1 General Specifications
Item Description
Technical Specifications
This section describes the chassis dimensions, weight, power consumption, heat consumption, power supply performance, electromagnetic compatibility, and reliability. Table 9-1 lists the general specifications of the OptiX OSN 550. Table 9-1 General specifications of the OptiX OSN 550
Dimensions 88 mm x 442 mm x 220 mm (H x W x D) Weight Power Consumpti on 10 kg Maximum power consumption: 240 W Typical power consumption: 142 W Board configuration for typical power consumption: 2 x PCXLX + 3 x EM6F + 1 x MD1 + FAN + 2 x PIU, as shown in the figure.
SL OT SLO T 10 10 (PIU) S LOT (PI U) SLOT 11 11 SL OT (FAN) SLO T (FAN) 9 9 (PI U) (PIU) SL OT 7 (C ST/CSH ) SLOT 7 (CSH) SL OT 5 (EX T) SL OT 3 (EX T) SLOT 3 (MD1 SLOT 1 (EXT ) SLOT 1 (MD1)
Maximum heat consumption: 819 BTU/h Typical heat consumption: 485 BTU/h DC power supply Rated voltage: -48 V or -60 V Voltage range: -38.4 V to -72 V AC power supply Rated voltage: 110/220 V Voltage range: 100 V to 240 V
Issue 01 (2011-06-30)
75
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Electromag Complies with EMC Class A. netic Compatibili ty Reliability System availability: 0.9999965 Average annual repair rate: < 1.5% Mean time to repair (MTTR): 1 hour Mean time between failures (MT BF): 33.08 years
Issue 01 (2011-06-30)
76
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Item Servic e
Description Service Type Description Maximum Re ceiving Capability FE (electrical port): 36 FE (optical port): 48 10GE (optical port) PCXLX/ PCXX: 2 Service Port Description 10/100BASETX 100Base-FX 10GBASELR (LAN) 10GBASELW (WAN) 10GBASEER (LAN) 10GBASEEW (WAN) 10GBASEZR (LAN) 10GBASEZW (WAN) Connector RJ-45
Etherne Supports Native ETH t and ETH PWE3 service services. Format of Ethernet data frames: IEEE 802.3 and Ethernet II Jumbo frames MTU length: 1518 bytes to 9600 bytes (1620 bytes, by default) MPLS function support VLAN function support. The VLAN IDs range from 1 to 4094.
LC LC
QinQ support GE (optical Size of a MAC port) address table: 16 KB PCXLG/ (including static PCXGA/ entries) PCXGB: 14 GE (electrical port): 12
Issue 01 (2011-06-30)
77
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Item
Description CES service Service type: 192xE1 point-to-point service Encapsulation types: CESoPSN SAToP Compression of idle timeslots: supported (only for CESoPSN encapsulation) Jitter compensation buffering time: 375 us to 16000 us Packet loading time: 125 us to 5000 us CES ACR: supported Retiming: supported ATM/I MA service Number of ATM connections: 256 ATM traffic management ATM encapsulation format N-to-one VPC N-to-one VCC One-to-one VPC One-to-one VCC Maximum number of concatenated ATM cells: 31 ATM OAM: F4 (VP layer) and F5 (VC layer) Maximum number of IMA groups: 32 Maximum number of members in an IMA group: 16 192xE1 75/120-ohm smart E1 port Anea 96 75/120-ohm smart E1 port Anea 96
Protec tion
MPLS APS
Maximum number of protection groups: 64 Switching duration not more than 100 ms
NOTE MP LS AP S and P W AP S share 64 protection group resources.
Issue 01 (2011-06-30)
78
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Item
Description PW APS Maximum number of protection groups: 64 Switching duration not more than 100 ms
NOTE MP LS AP S and P W AP S share 64 protection group resources.
MSTP
Supports the MSTP protocol that generates only the CIST . The MSTP protocol provides functions equivalent to that of the RSTP protocol. Point-point and point-multipoint LPT Switching duration not more than 5s Intra-board LAG and inter-board LAG A maximum of 16 LAGs. Each LAG has a maximum of 8 members. Switching duration not more than 500 ms T unnel OAM and PW OAM Maximum number of MPLS OAM resources: 128
NOTE MP LS OAM and P W OAM share 128 OAM resources.
LPT LAG
Maint enanc e
MPLS OAM
ETH-O AM
Supports the following IEEE 802.1ag OAM functions: Management of OAM maintenance points Continuity check (CC) Loopback (LB) Link trace (LT) Supports the following IEEE 802.3ah OAM functions: OAM auto-discovery Link performance monitoring Fault detection Loopback at the remote end Self-loop detection and self-looped port blocking Number of MD/MA/MEP: 64 Maximum number of ATM connections: 256
ATM OAM
Issue 01 (2011-06-30)
79
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Item
Description RMON Supports port-level and service-level RMON functions, in compliance with RFC 2819. Supports four RMON management groups: Ethernet statistics group, Ethernet history group, Ethernet alarm group, and Ethernet history control group. Port level: Basic Ethernet performance Extended Ethernet performance Service level: L2VPN T unnel PW
Synchronous Ethernet that complies with ITU-T G.8261 and ITU-T G.8262. Port receiving/transmitting synchronous Ethernet clocks: FE/GE/10GE Input/Output of SSM packets Clock frequency stability (hold-over mode): less than 50 ppb Maximum number of CES ACR clocks: 4 The clock performance complies with the ITU-T G.823 Traffic template. Tributary retiming. DiffServ Supports simple traffic classification by specifying PHB service classes for service flows based on their QoS information (C-VLAN priorities, S-VLAN priorities, DSCP values, or MPLS EXP values) carried by the packets. Complex traffic classification Supports traffic classification based on C-VLAN IDs, S-VLAN IDs, C-VLAN priorities, S-VLAN priorities, C-VLAN IDs + C-VLAN priorities, S-VLAN IDs + S-VLAN priorities, or DSCP values carried by packets. CAR Provides the CAR function for the traffic flows at ports. Shaping Supports traffic shaping for a specific port, prioritized queue, or traffic flow. Queue scheduling policies SP WRR SP+WRR
CES ACR
Other s
QoS
Issue 01 (2011-06-30)
80
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
SDH service
14xSTM-4
LC
14xSTM-16
LC
PDH service
252xE1/T1
Anea 96
Protection
SNCP
SNCP at the VC-12/VC-3/VC-4 levels Maximum number of protection groups: 1032 Switching duration not more than 50 ms MSP Ring at the STM-1, ST M-4 and STM-16 levels Maximum number of protection groups: 13 Switching duration not more than 50 ms Linear MSP at the STM-1, STM-4 and STM-16 levels Maximum number of 1+1/1:1 Linear MSP protection groups: 13 Switching duration not more than 50 ms Supported
MSP Ring
Linear MSP
PRBS
Physical layer clocks, including line clocks, tributary clocks, and two-input and two-output external clocks. The port impedance is 120 ohms or 75 ohms (a converter can be used to provide a 75-ohm clock port). Non-synchronization status message (SSM), standard SSM, and extended SSM protocols Tributary retiming Tracing mode, hold-over mode, and free-run mode
Issue 01 (2011-06-30)
81
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Issue 01 (2011-06-30)
82
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Table 9-5 Specifications of OptiX OSN 550's STM-1 optical ports Item Nominal bit rate Optical port type Transmission distance (km) Operating wavelength range (nm) Optical fiber type Launched optical power range (dBm) Receiver sensitivity (dBm) Minimum overload (dBm) Minimum extinction ratio (dB) Value 155520 kbit/s S-1.1 2 to 15 1261 to 1360 Single-mode LC -15 to -8 -28 -8 8.2 L-1.1 20 to 40 1263 to 1360 Single-mode LC -5 to 0 -34 -10 10 L-1.2 60 to 80 1480 to 1580 Single-mode LC -5 to 0 -34 0 10
NOTE Format of optical port type is defined as follows: transmission distance-signal rate.fiber type Explanation for optical port type "S-1.1" is as follows: "S" represents short distance; the first digit "1" represents STM-1 signals; the second digit "1" represents ITU-T G.652 fibers (1310 nm). Explanation for optical port type "L-1.1" is as follows: "L" represents long distance; the first digit "1" represents STM-1 signals; the second digit "1" represents ITU-T G.652 fibers (1310 nm). Explanation for optical port type "L-1.2" is as follows: "L" represents long distance; the first digit "1" represents STM-1 signals; the second digit "2" represents ITU-T G.652 fibers (1550 nm)..
Single-mode LC
Single-mode LC
Single-mode LC
Issue 01 (2011-06-30)
83
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Item Launched optical power range (dBm) Receiver sensitivity (dBm) Minimum overload (dBm) Minimum extinction ratio (dB)
NOTE Format of optical port type is defined as follows: transmission distance-signal rate.fiber type Explanation for optical port type "S-4.1" is as follows: "S" represents short distance; the first digit "4" represents STM-4 signals; the second digit "1" represents ITU-T G.652 fibers (1310 nm). Explanation for optical port type "L-4.1" is as follows: "L" represents long distance; the first digit "4" represents STM-4 signals; the second digit "1" represents ITU-T G.652 fibers (1310 nm). Explanation for optical port type "L-4.2" is as follows: "L" represents long distance; the first digit "4" represents STM-4 signals; the second digit "2" represents ITU-T G.652 fibers (1550 nm).
Issue 01 (2011-06-30)
84
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Item
Value
NOTE Format of optical port type is defined as follows: transmission distance-signal rate.fiber type Explanation for optical port type "S-16.1" is as follows: "S" represents short distance; the first two digits "16" represent STM-16 signals; the third digit "1" represents ITU-T G.652 fibers (1310 nm). Explanation for optical port type "L-16.1" is as follows: "L" represents long distance; the first two digits "16" represent STM-16 signals; the third digit "1" represents ITU-T G.652 fibers (1310 nm). Explanation for optical port type "L-16.2" is as follows: "L" represents long distance; the first two digits "16" represent STM-16 signals; the third digit "2" represents ITU-T G.652 fibers (1550 nm).
-8 8.2
-10 10
-10 10
Issue 01 (2011-06-30)
85
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Table 9-9 Specifications of OptiX OSN 550's GE optical ports Item Nominal bit rate (Mbit/s) Optical port type Optical fiber type Transmission distance (km) Operating wavelength (nm) Mean launched power (dBm) Receiver minimum sensitivity (dBm) Minimum overload (dBm) Minimum extinction ratio (dB) Value 1000 1000BASE-LX Single-mode LC 10 1270 to 1355 -9 to -3 -20 1000BASE-VX Single-mode LC 40 1270 to 1355 -5 to 0 -23 1000BASE-ZX Single-mode LC 80 1500 to 1580 -2 to +5 -23
-3 9
-3 9
-3 9
With different SFP modules, the equipment provides GE optical ports with different types and transmission distances.
Issue 01 (2011-06-30)
86
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Item Mean launched power (dBm) Receiver minimum sensitivity (dBm) Minimum overload (dBm) Minimum extinction ratio (dB)
0.5 6
-1 8.2
-7 9
Complies with ITU-T G.823 and G.824. Complies with ITU-T G.783.
Issue 01 (2011-06-30)
87
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Electrical Port Type Combined jitter Jitter transfer function Port type
1544 kbit/s
2048 kbit/s
Anea 96
Issue 01 (2011-06-30)
88
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
External Clock
Table 9-15 Specifications of external clock ports supported by the OptiX OSN 550 Item External synchronous source Frequency accuracy Pull-in or pull-out range Noise generation Noise toleration Noise transfer Transient response and holdover performance Performance 2048 kbit/s (in compliance with ITU-T G.703) or 2048 kHz (in compliance with ITU-T G.703) Complies with ITU-T G.813
Issue 01 (2011-06-30)
89
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Orderwire Ports
Table 9-18 Specifications of orderwire ports supported by the OptiX OSN 550 Item Transmission channel Orderwire type Pair in each direction Impedance (ohm) Performance Bytes E1 and E2 in the SDH overhead Addressing call One symmetrical pair 600
Issue 01 (2011-06-30)
90
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
34060298
Optical transceiver, eSFP, 1310 EM6F/PCXLG/PCX nm, 1.25 Gbit/s, -5 dBm, 0 dBm, GA/PCXGB -23 dBm, LC, SM, 40 km Optical transceiver, eSFP, 1550 EM6F/PCXLG/PCX nm, 1.25 Gbit/s, -2 dBm, 5 dBm, GA/PCXGB -23 dBm, LC, SM, 80 km Optical transceiver, SFP, Tx 1310 nm/Rx 1490 nm, 1.25 Gbit/s, -9 dBm, -3 dBm, -19.5 dBm, LC, SM, 10 km Optical transceiver, SFP,Tx1490 nm/Rx1310 nm, 1.25 Gbit/s, -3 dBm, -9 dBm, -19.5 dBm, LC, SM,10 km Optical transceiver, eSFP, 1310 nm, STM-1, -15 dBm, -8 dBm, -31 dBm, LC, SM, 15 km Optical transceiver, eSFP, 1310 nm, STM-1, -5 dBm, 0 dBm, -37 dBm, LC, SM, 40 km EM6F/PCXLG/PCX GA/PCXGB
34060360
34060470
34060475
EM6F/PCXLG/PCX GA/PCXGB
34060276
EF8F
34060281
EF8F
Issue 01 (2011-06-30)
91
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Name
Specification Optical transceiver, eSFP, 1550 nm, STM-1, -5 dBm, 0 dBm, -37 dBm, LC, SM, 80 km Optical transceiver, eSFP(industry), 1310 nm, ST M-1, -15 dBm, -8 dBm, -31 dBm, LC, SM, 15 km Optical transceiver, eSFP(industry), 1310 nm, ST M-1, -5 dBm, 0 dBm, -37 dBm, LC, SM, 40 km Optical transceiver, eSFP(industry), 1550 nm, ST M-1, -5 dBm, 0 dBm, -37 dBm, LC, SM, 80 km Optical transceiver, eSFP, Tx 1310 nm/Rx 1550 nm, ST M-1, -15 dBm, -8 dBm, -32 dBm, LC/PC, SM, 15 km Optical transceiver, eSFP, Tx 1550 nm/Rx 1310 nm, ST M-1, -15 dBm, -8 dBm, -32 dBm, LC/PC, SM, 15 km Optical transceiver, eSFP, Tx 1310 nm/Rx 1550 nm, ST M-1, -5 dBm, 0 dBm, -32 dBm, LC/PC, SM, 40 km Optical transceiver, eSFP, Tx 1550 nm/Rx 1310 nm, ST M-1, -5 dBm, 0 dBm, -32 dBm, LC/PC, SM, 40 km
34060307
EF8F
34060308
EF8F
34060309
EF8F
34060363
EF8F
34060364
EF8F
34060328
EF8F
34060329
EF8F
Table 9-21 provides the specifications for 10-Gigabit small form-factor pluggable transceiver (XFP) optical modules on the OptiX OSN 550. Table 9-21 XFP Optical Modules That the OptiX OSN 550 Supports Part Number 34060313 Name Specification Applicable Board PCXLX/PCXX
9.95 Gbit/s to Optical transceiver, XFP, 1310 10.71 Gbit/s XFP nm, 9.95 Gbit/s to 10.71 optical module Gbit/s, -6 dBm, -1 dBm, -14.4 dBm, LC, SM, 10 km
Issue 01 (2011-06-30)
92
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Name 9.95 Gbit/s to 11.1 Gbit/s XFP optical module 9.95 Gbit/s to 11.1 Gbit/s XFP optical module
Specification Optical transceiver, XFP, 1550 nm, 9.95 Gbit/s to 11.1 Gbit/s, -1 dBm, 2 dBm, -15 dBm, LC, SM, 40 km Optical transceiver, XFP, 1550 nm, 9.95 Gbit/s to 11.1 Gbit/s, 0 dBm, 4 dBm, -24 dBm, LC, SM, 80 km
34060361
PCXLX/PCXX
Table 9-22 lists the definitions of indicators supported by the boards on the OptiX OSN 550. Table 9-22 Definitions of indicators supported by the boards on the OptiX OSN 550 Indicator ST AT State On (green) On (red) Off Meaning The board is working properly. The board hardware is faulty. The board is not working or created. There is no power supplied to the system. When the board is being powered on or reset, the software is being loaded. When the board is being powered on or reset, the board software is in BIOS boot state. Applicable Board PCX (PCXLX/PCXX/PC XLG/PCXGA/PCX GB)/MD1/EM6T/E M6F/EF8F/SL1D/S L4D/SL1Q/SP3D/P L3T/AUX PCX (PCXLX/PCXX/PC XLG/PCXGA/PCX GB)/EM6T/EM6F
PROG
Blinks on (green) and off at 100 ms intervals Blinks on (green) and off at 300 ms intervals
Blinks on (red) and When the board is being off at 100 ms powered on or reset, the intervals BOOT ROM self-check fails. On (green) The upper layer software is being initialized.
Issue 01 (2011-06-30)
93
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Indicator
State On (red)
Meaning When the board is being powered or reset, the memory self-check fails or loading upper layer software fails. When the board is running, the logic file or upper layer software is lost. The pluggable storage card is faulty. The software is running normally. The clock is normal. The clock source is lost or is switched. The system/service is working properly. A critical or major alarm occurs in the system/services. A minor or remote alarm occurs in the system/services. For the PCX board, there is no power supplied to the system. The board is standby under 1+1 protection. For the service board, no service is configured.
Applicable Board
PCX (PCXLX/PCXX/PC XLG/PCXGA/PCX GB) PCX (PCXLX/PCXX/PC XLG/PCXGA/PCX GB)/MD1/EM6T/E M6F/EF8F/SL1D/S L4D/SP3D/AUX
ACT
On (green)
The board is active under 1+1 protection. The board is already activated under no protection. The board is standby under 1+1 protection. The board is not activated under no protection. The GE port is connected correctly, and is not receiving or transmitting data. The GE port is receiving or transmitting data.
Off
LINK1/LIN K2
On (green)
EM6F
Blinking (yellow)
Issue 01 (2011-06-30)
94
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Indicator
State Off
Meaning The GE port is connected correctly or is abnormal. The optical port on the board reports the R_LOS alarm. The optical port on the board receives too strong power. The optical port on the board receives too weak power. The optical port on the board reports the MS_RDI alarm. The optical port on the board is not reporting the R_LOS alarm. The port is physically connected (link up) but is not receiving or transmitting data The port on the board receives too strong power.
Applicable Board
LOS/LOS1/ LOS2
On (red) Blinking (red) three times every second Blinking (red) one time every second Blinking (red) three times every second Off
L/A
On (green)
Blinking (red) three times every second, 300 ms on and 300 ms off Blinking (red) three times every second, 300 ms on and 700 ms off Blinking (orange)
The port is normal (link up) and is receiving and transmitting data. The optical fiber is disconnected from the port or the port is abnormal (link down/LOS). Power is being supplied. Power is off or power supplies are connected incorrectly. The fan board is working properly. The fan board is faulty. The fan board is not powered on or is not installed. FAN PIU
Off
PWR
On (green) Off
FAN
Issue 01 (2011-06-30)
95
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
State On (red)
Issue 01 (2011-06-30)
96
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
This section provides the requirements on the operation environment for the OptiX OSN 550.
Climate
Table 9-24 lists the climate requirements for the storage environment. Table 9-24 Climate requirements for the storage environment Item Altitude Atmospheric pressure Temperature Temperature change rate Relative humidity Solar radiation Heat radiation Wind speed Range 4000 m 70-106 kPa -40C to +70C 1C/min 5% to 100% 1120 W/s2 600 W/s2 30 m/s
Waterproofing Requirements
Requirements for storing equipment on site: Generally, the equipment must be stored indoors. No water should remain on the floor or leak into the equipment crate. The equipment should be placed away from areas where water leakage is possible (for example, do not place near automatic fire-fighting extinguishing and heating systems. Ensure all the following four conditions if the equipment is stored outdoors: The crate is intact. Proper rain-proofing measures are taken to prevent water from entering the crate. No water is on the ground where the crate is placed and water is not seeped into the crate. The carton is not exposed to direct sunlight.
Biological Environment
Avoid multiplication of microbes (such as eumycete and mycete). Control and exclude rodents (such as mice).
Air Cleanliness
The air must be free from explosive, electric-conductive, magnetic-conductive or corrosive dust.
Issue 01 (2011-06-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd. 97
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Table 9-25 lists the density limitations for mechanically active substances during storage. Table 9-25 Density requirements for mechanical active substances during storage Mechanical Active Substance Suspended dust Precipitable dust Sand particles Content 5.00 mg/m3 20.0 mg/m h 300 mg/m 3
Table 9-26 lists the density requirements for chemically active substances. Table 9-26 Density requirements for chemically active substances during storage Chemically Active Substance SO2 H2 S NO2 NH3 CL2 HCL HF O3 Content 0.30 mg/m3 0.10 mg/m3 0.50 mg/m3 1.00 mg/m3 0.10 mg/m3 0.10 mg/m3 0.01 mg/m3 0.05 mg/m3
Mechanical Stress
Table 9-27 lists the limitations for mechanical stress during storage. Table 9-27 Limitations for mechanical stress during storage Item Sinusoidal vibration Sub-Item Displacement Acceleration Frequency range Static load Static pressure Range 1.5 mm 5 m/s2 2-9 Hz 9-200 Hz
Static pressure = Product weight x (Maximum number of stacked layers that is specified on the product package - 1) x 5 x 9.8 (N)
Issue 01 (2011-06-30)
98
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Item
Sub-Item
Range
NOTE Static load is the pressure from the upside that the packaged equipment can tolerate when equipment is stacked in the specified manner.
Climate
Table 9-28 lists the climate requirements for the transportation environment. Table 9-28 Climate requirements for the transportation environment Item Altitude Aire pressure Temperature Temperature change rate Relative humidity Solar radiation Heat radiation Wind speed Range 4000 m 70-106 kPa -40C to +70C 1C/min 5% to 100% 1120 W/s2 600 W/s2 30 m/s
Waterproofing Requirement
Ensure the following conditions are met when transporting the equipment: The crate is intact. Proper rain-proofing measures are taken on the vehicle to prevent water from entering the crate. No water is present in the vehicle.
Biological Environment
Avoid multiplication of microbes (such as eumycete and mycete). Keep rodents such as mice away.
Issue 01 (2011-06-30)
99
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Air Cleanliness
The air must be free from explosive, electric-conductive, magnetic-conductive or corrosive dust. Table 9-29 lists the density limitations for mechanically active substances during transportation. Table 9-29 Density limitations for mechanically active substances during transportation Mechanically Active Substance Suspended dust Precipitable dust Sand particles Content No requirement 3.0 mg/m2 h 100 mg/m 3
Table 9-30 lists the density limitations for chemically active substances. Table 9-30 Density limitations for chemically active substances Chemically Active Substance SO2 H2 S NOx NH3 CL2 HCL HF O3 Content 1.00 mg/m3 0.50 mg/m3 1.00 mg/m3 3.00 mg/m3 0.50 mg/m3 0.03 mg/m3 0.10 mg/m3
Mechanical Stress
Table 9-31 lists the mechanical stress requirements for the transportation environment. Table 9-31 Mechanical stress requirements for the transportation environment Item Random vibration Sub-Item Acceleration spectral density Frequency range Range 1 m 2/s3 5-20 Hz -3 dBA 20-200 Hz
Issue 01 (2011-06-30)
100
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Item Impact
Sub-Item Response spectrum I (weight of sample > 50 kg) Response spectrum II (weight of sample 50 kg)
Drop
Weight (kg) < 10 < 15 < 20 < 30 < 40 < 50 < 100 > 100
Height (m) 1.0 1.0 0.8 0.6 0.5 0.4 0.3 0.1 Static pressure = Product weight x (Maximum number of stacked layers that is specified on the product package - 1) x 5 x 9.8 (N)
Static load
Static pressure
NOTE Impact response spectrum: maxi mum acceleration response curve that the equipment generates when struck with the stipulated impact. Static load is the pressure from the upside that the packaged equipment can tolerate when equipment is stacked in the specified manner.
Climate
Table 9-32 and Table 9-33 list the climate requirements for the operation environment of the OptiX OSN 550. Table 9-32 Requirements for temperature and humidity Working Temperature Long-term operating temperature: -5C to +55C Extended operating temperature: -5C to +65C Relative Humidity 5% to 95%
Issue 01 (2011-06-30)
101
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Working Temperature
Relative Humidity
NOTE The temperature and humidity values are tested at 1.5 m above the floor and 0.4 m in front of the equipment. Extended operating indicates that the successive operating time of the equipment does not exceed 4 hours, and the accumulated operating time per year does not exceed 90 days.
Table 9-33 Other climate requirements Item Altitude Air pressure Temperature change rate Solar radiation Heat radiation Wind speed Range 4000 m 70-106 kPa 30C/h 700 W/s2 600 W/s2 5 m/s
Biological Environment
Avoid multiplication of microbes (such as eumycete and mycete). Keep rodents such as mice away.
Air Cleanliness
The air must be free from explosive, electric-conductive, magnetic-conductive or corrosive dust. Table 9-34 lists the density limitations for mechanically active substances during operation. Table 9-34 Density limitations for mechanically active substances during operation Mechanically Active Substance Dust particle Suspended dust Precipitable dust Sand particles Content 3x10 5 /m3 0.2 mg/m3 1.5 mg/m .h 20 mg/m 3
Table 9-35 lists the density limitations for chemically active substances.
Issue 01 (2011-06-30)
102
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
9 Technical Specifications
Table 9-35 Density limitations for chemically active substances Chemically Active Substance SO2 H2 S NH3 CL2 HCL HF O3 NOx Content 0.30 mg/m3 0.10 mg/m3 1.00 mg/m3 0.10 mg/m3 0.10 mg/m3 0.01 mg/m3 0.05 mg/m3 0.50 mg/m3
Mechanical Stress
Table 9-36 lists the limitations for mechanical stress during operation. Table 9-36 Limitations for mechanical stress during operation Item Sinusoidal vibration Sub-Item Velocity Acceleration Frequency range Non-steady impact Impact response spectrum Range 5 mm/s 5-62 Hz 2 m/s 62-200 Hz
NOTE Impact response spectrum: maxi mum acceleration response curve that the equipment generates when struck with the stipulated impact.
Issue 01 (2011-06-30)
103
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
10
Energy Conservation
The OptiX 550 complies with RoHS directive (2002/96/CE) and WEEE directive (2002/95/CE)
The OptiX OSN 550 adopts a variety of technologies to reduce equipment energy. Uses an easy scheme for board design. Replaces ordinary chips with ASIC chips that require low power consumption. Uses highly efficient power modules.
Environmental Protection
The is designed according to the requirements of environmental protection. The product complies with RoHS directive. The equipment is amply packaged while materials as conserved. The size of the package containing the equipment and accessories is at most three times the size of the net equipment. The product is also designed for easy unpacking. All hazardous substances contained in the packaging decompose easily. Every plastic component that weighs over 25 g is labeled according to the standards of ISO 11469 and ISO 1043-1 to ISO 1043-4. All components and packages of the equipment are provided with standard labels for recycling. Plugs and connectors are easy to find, and the associated operations can be performed by using simple tools. All the attached materials, such as labels, are easy to remove. Certain types of identifying information, such as silkscreens, are printed on the front panel or subrack.
Issue 01 (2011-06-30)
104
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
11 Standard Compliance
11
11.1 ITU-T Recommendations
Table 11-1 ITU-T recommendations Recommendation ITU-T G.664 ITU-T G.702 ITU-T G.703 ITU-T G.704 ITU-T G.706 ITU-T G.707 ITU-T G.773 ITU-T G.774 ITU-T G.774.1 ITU-T G.774.2 ITU-T G.774.3 ITU-T G.774.4 Description
Standard Compliance
This section provides the ITU-T Recommendations that the OptiX OSN 550 complies with.
Optical safety procedures and requirements for optical transport systems Digital hierarchy bit rates Physical/electrical characteristics of hierarchical digital interfaces Synchronous frame structures used at 1544, 6312, 2048, 8448 and 44,736 kbit/s hierarchical levels Frame alignment and cyclic redundancy check(CRC) procedures relating to basic frame structures defined in Recommendation G.704 Network node interface for the synchronous digital hierarchy(SDH) Protocol suites for Q-interfaces for management of transmission systems Synchronous digital hierarchy(SDH) management information model for the network element view Synchronous Digital Hierarchy(SDH) performance monitoring for the network element view Synchronous digital hierarchy(SDH) configuration of the payload structure for the network element view Synchronous digital hierarchy(SDH) management of multiplex-section protection for the network element view Synchronous digital hierarchy(SDH) management of the sub-network connection protection for the network element view
Issue 01 (2011-06-30)
105
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
11 Standard Compliance
Recommendation ITU-T G.774.5 ITU-T G.774.6 ITU-T G.774.7 ITU-T G.774.9 ITU-T G.774.10 ITU-T G.775
Description Synchronous digital hierarchy(SDH) management of connection supervision functionality(HCS/LCS) for the network element view Synchronous digital hierarchy(SDH) unidirectional performance monitoring for the network element view Synchronous digital hierarchy(SDH) management of lower order path trace and interface labeling for the network element view Synchronous digital hierarchy(SDH) configuration of linear multiplex section protection for the network element view Synchronous digital hierarchy(SDH) configuration of linear multiplex section protection for the network element view Loss of Signal(LOS), Alarm Indication Signal(AIS) and Remote Defect Indication(RDI) defect detection and clearance criteria for PDH signals Common equipment management function requirements Vocabulary of terms for synchronous digital hierarchy(SDH) networks and equipment Synchronization layer functions Characteristics of synchronous digital hierarchy(SDH) equipment functional blocks Synchronous digital hierarchy(SDH) management Architecture of transport networks based on the synchronous digital hierarchy(SDH) Generic functional architecture of transport networks Characteristics of transport equipment - Description methodology and generic functionality Generic protection switching - Linear trail and sub-network protection Definitions and terminology for synchronization networks Timing characteristics of primary reference clocks Timing requirements of slave clocks suitable for use as node clocks in synchronization networks Timing characteristics of SDH equipment slave clocks(SEC) Error performance of an international digital connection operating at a bit rate below the primary rate and forming part of an integrated services digital network Controlled slip rate objectives on an international digital connection
ITU-T G.7710 ITU-T G.780 ITU-T G.781 ITU-T G.783 ITU-T G.784 ITU-T G.803 ITU-T G.805 ITU-T G.806 ITU-T G.808.1 ITU-T G.810 ITU-T G.811 ITU-T G.812 ITU-T G.813 ITU-T G.821
ITU-T G.822
Issue 01 (2011-06-30)
106
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
11 Standard Compliance
Recommendation ITU-T G.823 ITU-T G.825 ITU-T G.826 ITU-T G.828 ITU-T G.829 ITU-T G.831 ITU-T G.832 ITU-T G.841 ITU-T G.842 ITU-T G.957 ITU-T G.958 ITU-T G.7043/Y.1343 ITU-T G.8010 ITU-T G.8011 ITU-T G.8011.1 ITU-T G.8011.2 ITU-T G.8012 ITU-T G.8021 ITU-T G.8110 ITU-T G.8110.1 ITU-T G.8121 ITU-T G.8112 ITU-T G.8131
Description The control of jitter and wander within digital networks which are based on the 2048 kbit/s hierarchy The control of jitter and wander within digital networks which are based on the synchronous digital hierarchy(SDH) Error performance parameters and objectives for international, constant bit rate digital paths at or above the primary rate Error performance parameters and objectives for international, constant bit rate synchronous digital paths Error performance events for SDH multiplex and regenerator sections Management capabilities of transport networks based on the synchronous digital hierarchy(SDH) Transport of SDH elements on PDH networks - Frame and multiplexing structures Types and characteristics of SDH network protection architectures Inter-working of SDH network protection architectures Optical interfaces for equipments and systems relating to the synchronous digital hierarchy Digital line systems based on the synchronous digital hierarchy for use on optical fiber cables Virtual concatenation of Plesiochronous Digital Hierarchy (PDH) signals Architecture of Ethernet layer networks Ethernet over Transport - Ethernet services framework Ethernet private line service Ethernet virtual private line service Ethernet UNI and Ethernet over transport NNI Characteristics of Ethernet transport network equipment functional blocks MPLS layer network architecture Application of MPLS in the transport network Characteristics of transport MPLS equipment functional blocks Interfaces for the transport MPLS (T-MPLS) hierarchy Protection switching for transport MPLS (T-MPLS) networks
Issue 01 (2011-06-30)
107
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
11 Standard Compliance
Recommendation ITU-T G.8261 ITU-T G.8262 ITU-T G.8264 ITU-T Y.1541 ITU-T Y.1710 ITU-T Y.1730 ITU-T Y.1711 ITU-T Y.1720 ITU-T I.610 ITU-T Y.1291
Description Timing and synchronization aspects in packet networks Timing characteristics of synchronous Ethernet equipment slave clock (EEC) Timing distribution through packet networks Network performance objectives for IP-based services Requirements for OAM functionality for MPLS networks Requirements for OAM functions in Ethernet based networks and Ethernet services Operation & Maintenance mechanism for MPLS networks Protection switching for MPLS networks B-ISDN operation and maintenance principles and functions An architectural framework for support of quality of service (QoS) in packet networks
Issue 01 (2011-06-30)
108
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
11 Standard Compliance
Standard RFC 4221 RFC 4377 RFC 4378 RFC 3032 RFC 3443 RFC 3916 RFC 3985 RFC 4197 RFC 4385 RFC 4446 RFC 0826 RFC 3270 RFC 4448 RFC 4553 RFC 5085 RFC 5086 RFC 4717 RFC 4816 RFC 4385 RFC 5254 draft-ietf-pwe3-seg mented-pw-03
Description Multiprotocol label switching (MPLS) management overview Operations and management (OAM) requirements for multi-protocol label switched (MPLS) networks A framework for multi-protocol label switching (MPLS) operations and management (OAM) MPLS label stack encoding Time to live (TTL) processing in multi-protocol label switching (MPLS) networks Requirements for pseudo-wire emulation edge-to-edge (PWE3) Pseudo wire emulation edge-to-edge (PWE3) architecture Requirements for edge-to-edge emulation of time division multiplexed (TDM) circuits over packet switching networks Pseudowire emulation edge-to-edge (PWE3) control word for use over an MPLS PSN IANA allocations for pseudowire edge to edge emulation (PWE3) Ethernet address resolution protocol Multi-protocol label switching (MPLS) support of differentiated services Encapsulation methods for transport of Ethernet over MPLS networks Structure-agnostic time division multiplexing (TDM) over packet (SAT oP) Pseudo wire virtual circuit connectivity verification (VCCV) Structure-Aware Time Division Multiplexed (TDM) Circuit Emulation Service over Packet Switched Network (CESoPSN) Encapsulation Methods for Transport of Asynchronous Transfer Mode (ATM) over MPLS Networks Pseudowire Emulation Edge-to-Edge (PWE3) Asynchronous Transfer Mode (ATM) Transparent Cell Transport Service Pseudowire emulation edge-to-edge (PWE3) control word for use over an MPLS PSN Requirements for Multi-Segment Pseudowire Emulation Edge-to-Edge (PWE3) Segmented pseudo wire
Issue 01 (2011-06-30)
109
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
11 Standard Compliance
Standard
Description
draft-ietf-pwe3-ms-p Requirements for inter domain pseudo-wires w-requirements-03 draft-ietf-pwe3-ms-p An architecture for multi-segment pseudo wire emulation w-arch-02 edge-to-edge RFC 3644 RFC 2212 RFC 2474 RFC 2475 RFC 2597 RFC 2698 RFC 3246 RFC 3270 Policy quality of service (QoS) Information model Specification of guaranteed quality of service Definition of the differentiated services field (DS Field) in the IPv4 and IPv6 headers An architecture for differentiated services Assured forwarding PHB group A two rate three color marker An expedited forwarding PHB (Per-hop behavior) Multi-protocol label switching (MPLS) support of differentiated services
Issue 01 (2011-06-30)
110
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
11 Standard Compliance
IEC 61000-4-3
IEC 61000-4-4
Issue 01 (2011-06-30)
111
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
11 Standard Compliance
Description Safety of laser products Dimensions of mechanical structures of the 482.6 mm (19 in) series
Issue 01 (2011-06-30)
112
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
A
A.1 A.2 A.3 A.4 A.5 Numerics A B C D A.6 E A.7 A.8 A.9 F G H
A.10 I A.11 J
A.12 L A.13 M A.14 N A.15 O A.16 P A.17 Q A.18 R A.19 S A.20 T A.21 U A.22 V A.23 W
Issue 01 (2011-06-30)
113
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
A.1 Numerics
1+1 prote ction An architecture that has one normal traffic signal, one working SNC/trail, one protection SNC/trail and a permanent bridge. At the source end, the normal traffic signal is permanently bridged to both the working and protection SNC/trail. At the sink end, the normal traffic signal is selected from the better of the two SNCs/trails. Due to the permanent bridging, the 1+1 architecture does not allow an extra unprotected traffic signal to be provided. IEEE 802.3 Physical Layer specification for a 100 Mb/s CSMA/CD local area network. IEEE 802.3 Physical Layer specification for a 100 Mb/s CSMA/CD local area network over two pairs of Category 5 unshielded twisted-pair (UTP) or shielded twisted-pair (STP) wire. An Ethernet specification that uses the twisted pair cable with the transmission speed as 10 Mbit/s and the transmission distance as 100 meters. An architecture that has N normal service signals, N working SNCs/trails, and one protection SNC/trail. It may have one extra service signal. Pulse per second, which, strictly speaking, is not a time synchronization signal. This is because 1PPS provides only the "gauge" corresponding to the UTC second, but does not provide the information about the day, month, or year. Therefore, 1PPS is used as the reference for frequency synchronization. On certain occasions, 1PPS can also be used on other interfaces for high precision timing. Reshaping, Retiming, Regenerating.
100BASE-T 100BASE-TX
10BASE-T
1PPS
3R
A.2 A
ABR AC ACAP Available Bit Rate Alternating Current A channel configuration method, which uses two adjacent channels (a horizontal polarization wave and a vertical polarization wave) to transmit two signals. The process in which the standby cross-connect board automatically takes the place of the active one. If there are two cross-connect boards on the SDH equipment, which are in hot back-up relation of each other, the operation reliability is improved. When both the cross-connect boards are in position, the one inserted first is in the working status. Unplug the active board, the standby one will run in the working status automatically. When the active cross-connect board fails in self-test, the board is pulled out, the board power supply fails or the board hardware operation fails, the standby cross-connect board can automatically take the place of the active one.
Issue 01 (2011-06-30)
114
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
add/drop multiplexer
Network elements that provide access to all or some subset of the constituent signals contained within an ST M-N signal. The constituent signals are added to (inserted), and/or dropped from (extracted) the STM-N signal as it passed through the ADM. See add/drop multiplexer The information structure which provides adaptation between the higher order path layer and the multiplex section layer. It consists of an information payload (the higher order VC) and a AU pointer which indicates the offset of the payload frame start relative to the multiplex section frame start. One or more administrative units occupying fixed, defined positions in an STM payload. An AUG consists of AU-4s. A user who has authority to access all the Management Domains of the product. He or she has access to the whole network and to all the management functionalities. The time to live before an object becomes invalid. Alarm Indication Signal A message reported when a fault is detected by a device or by the network management system during the process of polling devices. Each alarm corresponds to a recovery alarm. After a recovery alarm is received, the status of the corresponding alarm changes to cleared. A function wherein an alarm generated on the device side is immediately and automatically reported to the NMS. After an alarm is reported, an alarm panel prompts, and the user can view the details of the alarm. The cable for generation of visual or audio alarms. An alarm management method. Alarms are detected and reported to the NMS system, and whether the alarm information is displayed and saved is decided by the alarm filtering status. An alarm with the filtering status set to "Filter" is not displayed and saved on the NMS, but is monitored on the NE. A function that indicates the alarm status of an NE. On the cabinet of an NE, there are four indicators in different colors indicating the current alarm status of the NE. When the green indicator is on, the NE is powered on. When the red indicator is on, a critical alarm is generated. When the orange indicator is on, a major alarm is generated. When the yellow indicator is on, a minor alarm is generated. The ALM alarm indicator on the front panel of a board indicates the current status of the board. A code sent downstream in a digital network as an indication that an upstream failure has been detected and alarmed. It is associated with multiple transport layers.
alarm indication
Issue 01 (2011-06-30)
115
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Alarm inversion
For the port that has already been configured but has no service, this function can be used to avoid generating relevant alarm information, thus preventing alarm interference. The alarm report condition of the NE port is related to the alarm inverse mode (not inverse, automatic recovery and manual recovery) setting of the NE and the alarm inversion status (Enable and Disable) setting of the port. When the alarm inversion mode of NE is set to no inversion, alarms of the port will be reported as usual no matter whatever the inversion status of the port is. When the alarm inversion mode of the NE is set to automatic recovery, and the alarm inversion state of the port is set to Enabled, then the alarm of the port will be suppressed. The alarm inversion status of the port will automatically recover to "not inverse" after the alarm ends. For the port that has already been configured but not actually loaded with services, this function can be used to avoid generating relevant alarm information, thus preventing alarm interference. When the alarm inverse mode of the NE is set as "not automatic recovery", if the alarm inversion status of the port is set as Enable, the alarm of the port will be reported. An alarm management method. Alarms that are set to be masked are not displayed on the NMS or the NMS does not monitor unimportant alarms. The significance of a change in system performance or events. According to ITU-T recommendations, an alarm can have one of the following severities: Critical, Major, Minor, Warning. An alarm management method. Alarms that are set to be suppressed are not reported from NEs any more. See Automatic laser shutdown See Automatic Protection Switching Pertaining to, being, or characteristic of something that is not dependent on timing. A protocol for the transmission of a variety of digital signals using uniform 53 byte cells. A transfer mode in which the information is organized into cells; it is asynchronous in the sense that the recurrence of cells depends on the required or instantaneous bit rate. Statistical and deterministic values may also be used to qualify the transfer mode. See Asynchronous Transfer Mode See Automatic Transmit Power Control Reduction of signal magnitude or signal loss, usually expressed in decibels. See Administrative Unit See Administrative Unit Group An optional function of the IEEE 802.3u Fast Ethernet standard that enables devices to automatically exchange information over a link about speed and duplex abilities..
Alarm Masking
Alarm Se verity
Issue 01 (2011-06-30)
116
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Automatic laser shutdown Automatic Protection Switching Automatic Transmit Power Control
A technique (procedure) to automatically shutdown the output power of laser transmitters and optical amplifiers to avoid exposure to hazardous levels. Capability of a transmission system to detect a failure on a working facility and to switch to a standby facility to recover the traffic. A method of adjusting the transmit power based on fading of the transmit signal detected at the receiver.
A.3 B
backplane An electronic circuit board containing circuits and sockets into which additional electronic devices on other circuit boards or cards can be plugged. A periodic operation performed on the data stored in the database for the purposes of database recovery in case that the database is faulty. The backup also refers to data synchronization between active and standby boards. A range of transmission frequencies that a transmission line or channel can carry in a network. In fact, it is the difference between the highest and lowest frequencies the transmission line or channel. The greater the bandwidth, the faster the data transfer rate. Backward Defect Indicator See Bit Error Rate Used to measure the bit error rate (BER) of signals during transmission. The binding strap is 12.7 mm wide, with one hook side (made of transparent polypropylene material) and one mat side (made of black nylon material). A method of error monitoring. With even parity an X-bit code is generated by equipment at the transmit end over a specified portion of the signal in such a manner that the first bit of the code provides even parity over the first bit of all X-bit sequences in the covered portion of the signal, the second bit provides even parity over the second bit of all X-bit sequences within the specified portion, and so on. Even parity is generated by setting the BIP-X bits so that there is an even number of 1s in each monitored partition of the signal. A monitored partition comprises all bits which are in the same bit position within the X-bit sequences in the covered portion of the signal. The covered portion includes the BIP-X. An incompatibility between a bit in a transmitted digital signal and the corresponding bit in the received digital signal. Ratio of received bits that contain errors. BER is an important index used to measure the communications quality of a network. See Building Integrated T iming Supply
backup
bandwidth
BIP
Issue 01 (2011-06-30)
117
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
A parallel path with several serial paths bundled together. It improves the data throughput capacity. See Bridge Protocol Data Unit Board Protection Switching A device that connects two or more networks and forwards packets among them. Bridges operate at the physical network level. Bridges differs from repeaters because bridges store and forward complete packets, while repeaters forward all electrical signals. Bridges differ from routers because bridges use physical addresses, while routers use IP addresses. The data messages that are exchanged across the switches within an extended LAN that uses a spanning tree protocol (STP) topology. BPDU packets contain information on ports, addresses, priorities and costs and ensure that the data ends up where it was intended to go. BPDU messages are exchanged across bridges to detect loops in a network topology. The loops are then removed by shutting down selected bridges interfaces and placing redundant switch ports in a backup, or blocked, state. The process of sending packets from a source to multiple destinations. All the ports of the nodes in the network can receive packets. A means of delivering information to all members in a network. The broadcast range is determined by the broadcast address. Base Station Controller Base Station Subsystem A function which integrates some simple WDM systems into products that belong to the OSN series. That is, the OSN products can add or drop several wavelengths directly. In the situation of multiple synchronous nodes or communication devices, one can use a device to set up a clock system on the hinge of telecom network to connect the synchronous network as a whole, and provide satisfactory synchronous base signals to the building integrated device. This device is called BIT S. Backbone WDM System
BWS
A.4 C
cabling cable trough captive nut CAR CAS CBR The method by which a group of insulated conductors is mechanically assembled or twisted together. The trough which is used for cable routing in the cabinet. See Floating nut See committed access rate Channel Associated Signaling See Constant Bit Rate
Issue 01 (2011-06-30)
118
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
CBS CCDP CCM CDR CDVT Cell Delay Variation Tolerance Centralized alarm system CE S CFM Chain network channel
Committed Burst Size Co-Channel Dual Polarization Continuity Check Message Clock and Data Recovery See Cell Delay Variation Tolerance This parameter measures the tolerance level a network interface has to aggressive sending (back-to-back or very closely spaced cells) by a connected device, and does not apply to end-systems. The system that gathers all the information about alarms into a certain terminal console. See circuit emulation service Connectivity Fault Management One type of network that all network nodes are connected one after one to be in series. A telecommunication path of a specific capacity and/or at a specific speed between two or more locations in a network. Channels can be established through wire, radio (microwave), fiber or a combination of the three. The amount of information transmitted per second in a channel is the information transmission speed, expressed in bits per second. For example, b/s, kb/s, Mb/s, Gb/s, and T b/s. Committed Information Rate A combination of two transmission channels permitting transmission in both directions between two points. A function with which the E1/T1 data can be transmitted through ATM networks. At the transmission end, the interface module packs timeslot data into ATM cells. These ATM cells are sent to the reception end through the ATM network. At the reception end, the interface module re-assigns the data in these ATM cells to E1/T1 timeslots. The CES technology guarantees that the data in E1/T1 timeslots can be recovered to the original sequence at the reception end. Common and Internal Spanning Tree CoS is a rule for queuing. It classifies the packets according to the service type field or the tag in packets, and specifies different priorities for them. All the nodes in DiffServ domain forwards the packets according to their priorities. A device that sends requests, receives responses, and obtains services from the server. Also called frequency synchronization. The signal frequency traces the reference frequency, but the start point does not need to be consistent. The method to keep the time on each node being synchronized with a clock source in a network.
Issue 01 (2011-06-30)
119
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Cell Loss Priority See Configuration Management A traffic control method that uses a set of rate limits to be applied to a router interface. CAR is a configurable method by which incoming and outgoing packets can be classified into Quality of Service (QoS) groups, and by which the input or output transmission rate can be defined. A process that combines multiple virtual containers. The combined capacities can be used a single capacity. The concatenation also keeps the integrity of bit sequence. A command file defining hardware configurations of an NE. With this file, an NE can collaborate with other NEs in an entire network. Configuration data is the key factor for normal running of an entire network. A network management function defined by the International Standards Organization (ISO). It involves installing, reinitializing & modifying hardware & software. To set the basic parameters of an operation object. An extra intra-network or inter-network traffic resulting in decreasing network service efficiency. A reference point where the output of a trail termination source or a connection is bound to the input of another connection, or where the output of a connection is bound to the input of a trail termination sink or another connection. The connection point is characterized by the information which passes across it. A bidirectional connection point is formed by the association of a contradirectional pair. A kind of service categories defined by the ATM forum. CBR transfers cells based on the constant bandwidth. It is applicable to service connections that depend on precise clocking to ensure undistorted transmission. A process in which multiple channels of low-rate signals are multiplexed into one or several channels of required signals. It refers to the speed and capability for a group of networking devices to run a specific routing protocol. It functions to keep the network topology consistent. A service that provides enhancements to an underlying service in order to meet the specific requirements of users. Used to protect optical fibers. See Class of Service Central Processing Unit See Cyclic Redundancy Check An alarm not handled or not acknowledged after being handled.
Concatenation
Configuration Data
Convergence
Issue 01 (2011-06-30)
120
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Performance data stored currently in a register. An NE provides two types of registers, namely, 15-minute register and 24-hour register, to store performance parameters of a performance monitoring entity. The two types of registers stores performance data only in the specified monitoring period. A procedure used in checking for errors in data transmission. CRC error checking uses a complex calculation to generate a number based on the data transmitted. The sending device performs the calculation before transmission and includes it in the packet that it sends to the receiving device. The receiving device repeats the same calculation after transmission. If both devices obtain the same result, it is assumed that the transmission was error free. The procedure is known as a redundancy check because each transmission includes not only data but extra (redundant) error-checking values.
A.5 D
Data Communication Ne twork Digital Data Ne twork DC DCC DCD DCE DCN DDF DDN De fect Delay Measurement A communication network used in a TMN or between TMNs to support the data communication function. A high-quality data transport tunnel that combines the digital channel (such as fiber channel, digital microwave channel, or satellite channel) and the cross multiplex technology. Direct Current Data Communication Channel Data Carrier Detect Data Circuit-terminal Equipment See Data Communication Network See Digital Distribution Frame See Digital Data Network A limited interruption in the ability of an item to perform a required function. The time elapsed since the start of transmission of the first bit of the frame by a source node until the reception of the last bit of the loopbacked frame by the same source node, when the loopback is performed at the frame's destination node. A process applied to a composite signal formed by multiplexing, for recovering the original independent signals, or groups of these signals.
Demultiplexing
Issue 01 (2011-06-30)
121
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
De vice se t
A collection of multiple managed devices. By dividing managed devices into different device sets, users can manage the devices by using the U2000 in an easier way. If an operation authority over one device set is assigned to a user (user group), the authority over all the devices in the device set is assigned to the user (user group), thus making it unnecessary to set the operation authority over all the devices in a device set separately. It is recommended to configure device set by geographical region, network level, device type, or another criterion. A marker in the header of each IP packet that prompts network routers to apply differentiated grades of service to various packet streams. It is specified by the DiffServ policy proposed by the IETF (Internet Engineering Task Force). This allows Internet and other IP-based network service providers to offer different levels of service to customers. A service architecture that provides the end-to-end QoS function. It consists of a series of functional units implemented at the network nodes, including a small group of per-hop forwarding behaviors, packet classification functions, and traffic conditioning functions such as metering, marking, shaping and policing. A type of equipment used between the transmission equipment and the exchange with transmission rate of 2 to 155 Mbit/s to provide the functions such as cables connection, cable patching, and test of loops that transmitting digital signals. A signal in which information is represented by a limited number of discrete states number of discrete states (for example, high and low voltages) rather than by fluctuating levels in a continuous stream, as in an analog signal. In the pulse code modulation (PCM) technology, the 8 kHz sampling frequency is used and a byte contains 8 bits in length. Therefore, a digital signal is also referred to as a byte-based code stream. Digital signals, with simple structures and broad bandwidth, are easy to shape or regenerate, and are not easily affected by external interference. A board-level port protection technology used to detect unidirectional fiber cuts and to negotiate with the opposite end. Once a link down failure occurs on a port or a hardware failure occurs on a board, the services can automatically be switched to the slave board, achieving 1+1 protection for the inter-board ports. See Distributed Link Aggregation Group See Delay Measurement See Dual Node Interconnection A logical subscriber group based on which the subscriber rights are controlled. See Differentiated Services Code Point Digital Subscriber Line Digital Subscriber Line Access Multiplexer
DiffSe rv
Issue 01 (2011-06-30)
122
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
DSR DTE DTR Dual Node Inte rconnection DVB-ASI DVMRP DWDM
Data Set Ready Data T erminal Equipments Data T erminal Ready DNI provides an alternative physical interconnection point, between the rings, in case of an interconnection failure scenario. Digital Video Broadcast- Asynchronous Serial Interface Distance Vector Multicast Routing Protocol Dense Wavelength Division Multiplexing
A.6 E
E-AGGR Ear bracket ECC EFM E-LAN ElectroStatic Discharge E-Line Embe dded Control Channel EMS encapsulation See Ethernet aggregation A piece of angle plate with holes in it on a rack. It is used to fix network elements or components. See Embedded Control Channel Ethernet in the First Mile A type of Ethernet service that is based on a multipoint-to-multipoint EVC (Ethernet virtual connection). The sudden and momentary electric current that flows between two objects at different electrical potentials caused by direct contact or induced by an electrostatic field. A type of Ethernet service that is based on a point-to-point EVC (Ethernet virtual connection). A logical channel that uses a data communications channel (DCC) as its physical layer, to enable transmission of operation, administration, and maintenance (OAM) information between NEs. Element Management System A technology for layered protocols, in which a lower-level protocol accepts a message from a higher-level protocol and places it in the data portion of the lower-level frame. Protocol A's packets have complete header information, and are carried by protocol B as data. Packets that encapsulate protocol A have a B header, an A header, followed by the information that protocol A is carrying. Note that A could equal to B, as in IP inside IP. A path protocol which connects the host with various control units in a storage system. It is a serial bit stream transmission protocol. The transmission rate is 200 Mbit/s. A part, device, subsystem, functional unit, equipment, or system that can be considered individually. See Ethernet over Dual Domains See Ethernet Private Line
Issue 01 (2011-06-30)
123
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
EPLAN Equipment Serial Number ESCON ESD ESD jack ESD wrist strap ESN Ethe rnet
See Ethernet virtual private LAN service A string of characters that identify a piece of equipment and ensures correct allocation of a license file to the specified equipment. It is also called "equipment fingerprint". See Enterprise System Connection See ElectroStatic Discharge Electrostatic discharge jack. A hole in the cabinet or shelf, which connect the shelf or cabinet to the insertion of ESD wrist strap. Used to prevent the ElectroStatic Discharge (ESD) when you touch or operate a device or component. See Equipment Serial Number A LAN technology that uses Carrier Sense Multiple Access/Collision Detection. The speed of an Ethernet interface can be 10 Mbit/s, 100 Mbit/s, 1000 Mbit/s or 10000 Mbit/s. An Ethernet network features high reliability and is easy to maintain. A type of Ethernet service that is based on a multipoint-to-point EVC (Ethernet virtual connection). The Ethernet alarm group periodically obtain the statistics value to compare with the configured threshold. If the value exceeds the threshold, an event is reported. A type of boards. EoD boards bridge the PSN and TDM networks, enabling Ethernet service transmission across PSN and TDM networks. A type of Ethernet service provided by SDH, PDH, ATM, or MPLS networks. This service is carried over a dedicated bridge and point-to-multipoint connections. A type of Ethernet service that is provided with dedicated bandwidth and point-to-point connections on an SDH, PDH, ATM, or MPLS server layer network. A type of Ethernet service provided by SDH, PDH, ATM, or MPLS networks. This service is carried over a shared bridge and point-to-multipoint connections. A type of Ethernet service provided by SDH, PDH, ATM, or MPLS networks. This service is carried over a shared bridge and point-to-point connections. European Telecommunications Standards Institute See Ethernet virtual private line See Ethernet virtual private LAN service An operation to check whether the protection switching protocol functions properly. The protection switching is not really performed.
Ethe rnet aggregation Ethe rnet Alarm Group Ethe rnet over Dual Domains Ethe rnet Private LAN service Ethe rnet Private Line Ethe rnet virtual private LAN service Ethe rnet virtual private line ETSI EVPL EVPLAN Exe rcise Switching
Issue 01 (2011-06-30)
124
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
This command exercises ring protection switching of the requested channel without completing the actual bridge and switch. The command is issued and the responses are checked, but no working traffic is affected. The number of the subnet that an NE belongs to, for identifying different network segments in a WAN. The physical ID of an NE is comprised of the NE ID and extended ID. The traffic that is carried over the protection channels when that capacity is not used for the protection of working traffic. Extra traffic is not protected.
Extende d ID
extra traffic
A.7 F
Failure If the fault persists long enough to consider the ability of an item with a required function to be terminated. The item may be considered as having failed; a fault has now been detected. A feature in which for any link specified in a ring network, the source node is provided with certain bandwidth capacities if the data packets transmitted by the source node are constrained by the fairness algorithm. An algorithm designed to ensure the fair sharing of bandwidth among stations in the case of congestion or overloading. A failure to implement the function while the specified operations are performed. A fault does not involve the failure caused by preventive maintenance, insufficiency of external resources or intentional settings. See Fiber Channel See frequency diversity See fiber distributed data interface Forward Defect Indicator See Frame Delay Variation Fast Ethernet Code used to select/activate a service feature (for example, forwarding, using two or three digit codes preceded by * or 11 or #, and which may precede subsequent digit selection). See forwarding equivalence class See Forward Error Correction A kind of fiber used for connections between the subrack and the ODF, and for connections between subracks or inside a subrack.
Fairness
Issue 01 (2011-06-30)
125
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Fiber Channel
A high-speed transport technology used to build storage area networks (SANs). Fiber channel can be on the networks carrying ATM and IP traffic. It is primarily used for transporting SCSI traffic from servers to disk arrays. Fiber channel supports single-mode and multi-mode fiber connections. Fiber channel signaling can run on both twisted pair copper wires and coaxial cables. Fiber channel provides both connection-oriented and connectionless services. A new generation connection protocol which connects the host to various control units. It carries single byte command protocol through the physical path of fiber channel, and provides higher rate and better performance than ESCON. A device installed at the end of a fiber, optical source or receive unit. It is used to couple the optical wave to the fiber when connected to another device of the same type. A connector can either connect two fiber ends or connect a fiber end and a optical source (or a detector). A standard developed by the American National Standards Institute (ANSI) for high-speed fiber-optic local area networks (LANs). FDDI provides specifications for transmission rates of 100 megabits (100 million bits) per second on networks based on the token ring network. General name of optical fiber and cable. It refers to the physical entities that connect the transmission equipment, carry transmission objects (user information and network management information) and perform the transmission function in the transmission network. The optical fiber transmits optical signal, while the cable transmits electrical signal. The fiber/cable between NEs represents the optical fiber connection or cable connection between NEs. The fiber/cable between SDH NEs represents the connection relationship between NEs. At this time, the fiber/cable is of optical fiber type. See Fiber Connect First In First Out Floating nuts (or as they are more correctly named, 't ee nuts') have a range of uses but are more commonly used in the hobby for engine fixing (securing engine mounts to the firewall), wing fixings, and undercarriage fixing. An aggregation of packets that have the same characteristics. On the network management system or NE software, flow is a group of classification rules. On boards, it is a group of packets that have the same quality of service (QoS) operation. See Frame loss ratio For normal traffic signals, switches normal traffic signal to the protection section, unless an equal or higher priority switch command is in effect or SF condition exists on the protection section, by issuing a forced switch request for that traffic signal. A bit error correction technology that adds the correction information to the payload at the transmit end. Based on the correction information, the bit errors generated during transmission are corrected at the receive end.
Fiber Connect
Fiber Connector
fibe r/cable
Flow
Issue 01 (2011-06-30)
126
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
A class-based forwarding technology that classifies the packets with the same forwarding mode. Packets with the same FEC are processed similarly on an MPLS network. The division of FECs is flexible, and can be a combination of the source address, destination address, source port, destination port, protocol type, and VPN. Field Programmable Gate Array A frame, starting with a header, is a string of bytes with a specified length. Frame length is represented by the sampling circle or the total number of bytes sampled during a circle. A header comprises one or a number of bytes with pre-specified values. In other words, a header is a code segment that reflects the distribution (diagram) of the elements pre-specified by the sending and receiving parties. A measurement of the variations in the frame delay between a pair of service frames, where the service frames belong to the same CoS instance on a point to point ETH connection. A ratio, is expressed as a percentage, of the number of service frames not delivered divided by the total number of service frames during time interval T, where the number of service frames not delivered is the difference between the number of service frames arriving at the ingress ETH flow point and the number of service frames delivered at the egress ETH flow point in a point-to-point ETH connection. An operating condition of a clock, the output signal of which is strongly influenced by the oscillating element and not controlled by servo phase-locking techniques. In this mode the clock has never had a network reference input, or the clock has lost external reference and has no access to stored data, that could be acquired from a previously connected external reference. Free-run begins when the clock output no longer reflects the influence of a connected external reference, or transition from it. Free-run terminates when the clock output has achieved lock to an external reference. A diversity scheme in which two or more microwave frequencies with a certain frequency interval are used to transmit/receive the same signal and selection is then performed between the two signals to ease the impact of fading. File Transfer Protocol A full-duplex, or sometimes double-duplex system, allows communication in both directions, and, unlike half-duplex, allows this to happen simultaneously. Land-line telephone networks are full-duplex, since they allow both callers to speak and be heard at the same time. A good analogy for a full-duplex system would be a two-lane road with one lane for each direction.
FPGA frame
Free-run mode
FTP full-duplex
A.8 G
Gain The difference between the optical power from the input optical interface of the optical amplifier and the optical power from the output optical interface of the jumper fiber, which expressed in dB.
Issue 01 (2011-06-30)
127
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Gateway IP
When an NE accesses a remote network management system or NE, a router can be used to enable the TCP/IP communication. In this case, the IP address of the router is the gateway IP. Only the gateway NE requires the IP address. The IP address itself cannot identify the uniqueness of an NE. The same IP addresses may exist in different TCP/IP networks. An NE may have multiple IP addresses, for example, one IP address of the network and one IP address of the Ethernet port. A network element that is used for communication between the NE application layer and the NM application layer. Gigabit Ethernet A framing and encapsulation method which can be applied to any data type. It has been standardized by ITU-T SG15. See Generic Framing Procedure See Gateway Network Element Global Positioning System Global System for Mobile Communications Generic Traffic Shaping Graphic User Interface
Gateway Ne twork Element GE Generic Framing Procedure GFP GNE GPS GSM GTS GUI
A.9 H
half-duplex A transmitting mode in which a half-duplex system provides for communication in both directions, but only one direction at a time (not simultaneously). Typically, once a party begins receiving a signal, it must wait for the transmitter to stop transmitting, before replying. A connection mode in which a fiber jumper is used to connect the input optical interface to the output optical interface of a board to achieve signal loopback. High level Data Link Control See High Definition-Serial Digital Interface signal Header Error Control A type of QoS that controls the traffic of users and performs the scheduling according to the priority of user services. HQoS has an advanced traffic statistics function, and the administrator can monitor the usage of bandwidth of each service. Hence, the bandwidth can be allocated reasonably through traffic analysis. High definition video signal transported by serial digital interface.
Issue 01 (2011-06-30)
128
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
The confirmed alarm that has been saved in the memory and other external memories. The performance data that is stored in the history register or that is automatically reported and stored on the NMS. Higher Order Path Higher Order Path Termination See Hierarchical Quality of Service
A.10 I
IC IDU IEEE IETF IF IGMP IGMP Snooping Integrated Circuit Indoor Unit Institute of Electrical and Electronics Engineers Internet Engineering Task Force Intermediate Frequency See Internet Group Management Protocol A multicast constraint mechanism running on a layer 2 device. This protocol manages and controls the multicast group by listening to and analyzing Internet Group Management Protocol (IGMP) packets between hosts and Layer 3 devices. In this manner, the spread of the multicast data on layer 2 network can be prevented efficiently. See Inverse Multiplexing over ATM A control unit in the IMA protocol. It is a logical frame defined as M consecutive cells, numbered 0 to M-l, transmitted on each of the N links in an IMA group. The maximum amplitude of sinusoidal jitter at a given jitter frequency, which, when modulating the signal at an equipment input port, results in no more than two errored seconds cumulative, where these errored seconds are integrated over successive 30-second measurement intervals. A mechanism used to reduce the optical power of all the amplifiers in an adjacent regeneration section in the upstream to a safety level if the system detects the loss of optical signals on the link. If the fiber is broken, the device performance degrades, or the connector is not plugged well, the loss of optical signals may occur. With IPA, maintenance engineers will not be hurt by the laser sent out from the slice of broken fiber. The area for the interface boards on the subrack. The cables and optical fibers which are used for interconnecting electrical interfaces and optical interfaces within the cabinet.
Issue 01 (2011-06-30)
129
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Inte rnet Group Management Protocol Inverse Multiplexing over ATM IP IP address
One of the TCP/IP protocols for managing the membership of Internet Protocol multicast groups. It is used by IP hosts and adjacent multicast routers to establish and maintain multicast group memberships. A technique that involves inverse multiplexing and de-multiplexing of ATM cells in a cyclical fashion among links grouped to form a higher bandwidth logical link whose rate is approximately the sum of the link rates. Internet Protocol A 32-bit (4-byte) binary digit that uniquely identifies a host (computer) connected to the Internet for communication with other hosts in the Internet by transferring packets. An IP address is expressed in dotted decimal notation, consisting of decimal values of its 4 bytes, separated by periods (,), for example, 127.0.0.1. The first three bytes of an IP address identify the network to which the host is connected, and the last byte identifies the host itself. A technology that enables a DCC channel to carry TCP/IP protocol packets. The IP over DCC technology provides the TCP/IP protocol without using any extra overheads or service resources to ensure interconnection of management channels. See Intelligent power adjusting Intermedia System-Intermedia System Integrated Services Digital Network International Standard Organization Internet Service Provider Internal Spanning Tree International Telecommunication Union Telecommunication Standardization
IP ove r DCC
A.11 J
Jitter jitte r tolerance Short waveform variations caused by vibration, voltage fluctuations, and control system instability. Jitter tolerance is defined as the peak-to-peak amplitude of sinusoidal jitter applied on the input ATM-PON signal that causes a 1 dB optical power penalty at the optical equipment.
A.12 L
Label A short identifier that is of fixed length and local significance. It is used to uniquely identify the FEC to which a packet belongs. It does not contain topology information. It is carried in the header of a packet and does not contain topology information. See Link Aggregation Control Protocol
LACP
Issue 01 (2011-06-30)
130
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
See link aggregation group Local Area Network Link Access Procedure-SDH A component that generates directional optical waves of narrow wavelengths. The laser light has better coherence than ordinary light. The fiber system takes the semi-conductor laser as the light source. A concept used to allow the transport network functionality to be described hierarchically as successive levels; each layer being solely concerned with the generation and transfer of its characteristic information. A data forwarding method. In a LAN, a network bridge or 802.3 Ethernet switch transmits and distributes packet data based on the MAC address. Since the MAC address is at the second layer of the OSI model, this data forwarding method is called Layer 2 switch. See Loopback Loopback Message Loopback Reply Lucent Connector See Link Capacity Adjustment Scheme Liquid Crystal Display Local Craft Terminal A permission that the vendor provides for the user with a specific function, capacity, and duration of a product. A license can be a file or a serial number. Usually the license consists of encrypted codes. The operation authority granted varies with the level of the license. In the topology view, a link is used to identify the physical or logical connection between two topological nodes. A link is used to connect signaling points (SPs) and signaling transfer points (STPs) and transmit signaling messages. A method of bundling a group of physical interfaces together as a logical interface to increase bandwidth and reliability. For related protocols and standards, refer to IEEE 802.3ad. An aggregation that allows one or more links to be aggregated together to form a link aggregation group so that a MAC client can treat the link aggregation group as if it were a single link. LCAS in the virtual concatenation source and sink adaptation functions provides a control mechanism to hitless increase or decrease the capacity of a link to meet the bandwidth needs of the application. It also provides a means of removing member links that have experienced failure. The LCAS assumes that in cases of capacity initiation, increases or decreases, the construction or destruction of the end-to-end path is the responsibility of the network and element management systems.
Layer
laye r 2 switch
Link
Link Aggregation Control Protocol link aggregation group Link Capacity Adjustment Scheme
Issue 01 (2011-06-30)
131
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Logical Link Control See Loss Measurement When the switching condition is satisfied, this function disables the service from being switched from the working channel to the protection channel. When the service has been switched, the function enables the service to be restored from the protection channel to the working channel. Loss of Frame Loss of Multiframe A troubleshooting technique that returns a transmitted signal to its source so that the signal or message can be analyzed for errors. The loopback can be a inloop or outloop. Loss of Signal Loss measurement, a method used to collect counter values applicable for ingress and egress service frames where the counters maintain a count of transmitted and received data frames between a pair of MEPs. A lower performance limit which when exceeded by a performance event counter will trigger a threshold-crossing event. Lower Order Path Link State Pass Through Label Switched Path Label Switching Router Link Trace
LO F LO M Loopback
A.13 M
MA MAC Maintenance Association Maintenance Domain See Maintenance Association Medium Access Control TThat portion of a Service Instance, preferably all of it or as much as possible, the connectivity of which is maintained by CFM. It is also a full mesh of Maintenance Entities. The network or the part of the network for which connectivity is managed by connectivity fault management (CFM). The devices in a maintenance domain are managed by a single Internet service provider (ISP). See Metropolitan Area Network Switches normal traffic signal to the protection section, unless a failure condition exists on other sections (including the protection section) or an equal or higher priority switch command is in effect, by issuing a manual switch request for that normal traffic signal.
Issue 01 (2011-06-30)
132
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Mapping Marking-off template MBS MCF MCR MD Mean launched power MEP Metropolitan Area Ne twork
A procedure by which tributaries are adapted into virtual containers at the boundary of an SDH network. A quadrate cardboard with four holes. It is used to mark the positions of the installation holes for the cabinet. Maximum Burst Size Message Communication Function Minimum Cell Rate See Maintenance Domain The average power of a pseudo-random data sequence coupled into the fiber by the transmitter. Maintenance End Point A network that interconnects users with computer resources in a geographic area or region larger than that covered by even a large LAN but smaller than the area covered by an WAN. The term is applied to the interconnection of networks in a city into a single larger network (which may then also offer efficient connection to a wide area network). It is also used to mean the interconnection of several local area networks by bridging them with backbone lines. The latter usage is also sometimes referred to as a campus network. Management Information Base Maintenance Intermediate Point MOdulator-DEModulator Maintenance Point Maintenance Point Identification See Multiprotocol Label Switching Multiplex Section Multiplex Section Adaptation See Multiplex Section Overhead See Multiplex Section Protection Multiplex Section Termination Multiple Spanning Tree Instance See Multi-service transmission platform See Multiple Spanning Tree Protocol Maximum T ime Interval Error Maximum Transmission Unit
MIB MIP MO DEM MP MPID MPLS MS MSA MSOH MSP MST MSTI MSTP MSTP MTIE MTU
Issue 01 (2011-06-30)
133
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
A technology that uses short tags of fixed length to encapsulate packets in different link layers, and provides connection-oriented switching for the network layer on the basis of IP routing and control protocols. It improves the cost performance and expandability of networks, and is beneficial to routing. A platform based on the SDH platform, capable of accessing, processing and transmitting TDM services, ATM services, and Ethernet services, and providing unified management of these services. A process of transmitting data packets from one source to many destinations. The destination address of the multicast packet uses Class D address, that is, the IP address ranges from 224.0.0.0 to 239.255.255.255. Each multicast address represents a multicast group rather than a host. A protocol that can be used in a loop network. Using an algorithm, the MSTP blocks redundant paths so that the loop network can be trimmed as a tree network. In this case, the proliferation and endless cycling of packets is avoided in the loop network. The protocol that introduces the mapping between VLANs and multiple spanning trees. This solves the problem that data cannot be normally forwarded in a VLAN because in STP/RSTP, only one spanning tree corresponds to all the VLANs. The overhead that comprises rows 5 to 9 of the SOH of the STM-N signal. See SOH definition. A function, which is performed to provide capability for switching a signal between and including two multiplex section termination (MST ) functions, from a "working" to a "protection" channel. A procedure by which multiple lower order path layer signals are adapted into a higher order path or the multiple higher order path layer signals are adapted into a multiplex section.
A.14 N
NE NE Explorer See network element The main operation interface, of the network management system, which is used to manage the telecommunication equipment. In the NE Explorer, the user can query, manage and maintain the NE, boards, and ports on a per-NE basis. An NE contains both the hardware and the software running on it. One NE is at least equipped with one system control and communication(SCC) board which manages and monitors the entire network element. The NE software runs on the SCC board. The interface at a network node which is used to interconnect with another network node. A part of an Ethernet or other network, on which all message traffic is common to all nodes, that is, it is broadcast from one node on the segment and received by all others.
network element
Issue 01 (2011-06-30)
134
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Normal Link Pulse Network Management System See network node interface Network Parameter Control Non Real-T ime Variable Bit Rate Non Return to Zero code Network Service Access Point Network T ime Protocol
A.15 O
OA OADM OAM OAM auto-discove ry See Optical Amplifier See Optical Add/Drop Multiplexer Operations, Administration and Maintenance In the case of OAM auto-discovery, two interconnected ports, enabled with the Ethernet in the First Mile OAM (EFM OAM) function, negotiate to determine whether the mutual EFM OAM configuration match with each other by sending and responding to the OAM protocol data unit (OAMPDU). If the mutual EFM OAM configuration match, the two ports enter the EFM OAM handshake phase. In the handshake phase, the two ports regularly send the OAMPDU to maintain the neighborhood relation. See Optical Channel Protection See Optical Distribution Frame Outdoor Unit Out-of-frame Second Overhead Access Function Optical Line Terminal The capability of many programs and operating systems to display advice or instructions for using their features when so requested by the user. Optical Network Unit Out of Frame A device that can be used to add the optical signals of various wavelengths to one channel and drop the optical signals of various wavelengths from one channel. Devices or subsystems in which optical signals can be amplified by means of the stimulated emission taking place in a suitable active medium.
Issue 01 (2011-06-30)
135
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Optical attenuator
A passive device that increases the attenuation in a fiber link. It is used to ensure that the optical power of the signals received at the receive end is not extremely high. It is available in two types: fixed attenuator and variable attenuator. In an optical transmission link that contains multiple wavelengths, when a certain wavelength goes faulty, the services at the wavelength can be protected if the optical channel protection is configured. A component normally attached to an optical cable or a piece of apparatus to provide frequent optical interconnection/disconnection of optical fibers or cables. A frame which is used to transfer and spool fibers.
Optical Channel Protection Optical Connector Optical Distribution Frame Optical Inte rface Optical Time Domain Re flectometer orderwire OSI OSN OSPF O TDR O TU Optical transponder unit Output optical power Ove rhead
A component that connects several transmit or receive units. A device that sends a very short pulse of light down a fiber optic communication system and measures the time history of the pulse reflection to measure the fiber length, the light loss and locate the fiber fault. A channel that provides voice communication between operation engineers or maintenance engineers of different stations. Open Systems Interconnection Optical Switch Node Open Shortest Path First See Optical T ime Domain Reflectometer See Optical transponder unit A device or subsystem that converts the accessed client signals into the G.694.1/G.694.2-compliant WDM wavelength. The ranger of optical energy level of output signals. Extra bits in a digital stream used to carry information besides traffic signals. Orderwire, for example, would be considered overhead information.
A.16 P
Paire d slots pass-through T wo slots of which the overheads can be passed through by using the bus on the backplane. The action of transmitting the same information that is being received for any given direction of transmission.
Issue 01 (2011-06-30)
136
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Path
A performance resource object defined in the network management system. The left end of a path is a device node whose port needs to be specified and the right end of a path is a certain IP address which can be configured by the user. By defining a path in the network management system, a user can test the performance of a network path between a device port and an IP address. The tested performance may be the path delay, packet loss ratio or other aspects. Peak Burst Size Personal Computer Pulse Code Modulation Peak Cell Rate See Plesiochronous Digital Hierarchy See Power distribution unit See provider edge The memory space for performance event counts, including 15-min current performance register, 24-hour current performance register, 15-min historical performance register, 24-hour historical performance register, UAT register and CSES register. The object of performance event monitoring is the board functional module, so every board functional module has a performance register. A performance register is used to count the performance events taking place within a period of operation time, so as to evaluate the quality of operation from the angle of statistics. A limit for generating an alarm for a selected entity. When the measurement result reaches or exceeds the preset alarm threshold, the performance management system generates a performance alarm. A connection between two ATM end hosts. The connection consists of PVPs between the ATM end hosts and their respective switches, and SVPs between the switches. Protection Ground A cable which connects the equipment and the protection grounding bar. Usually, one half of the cable is yellow, whereas the other half is green. Protocol Independent Multicast-Sparse Mode Peak Information Rate Qualifying two time-varying phenomena, time-scales, or signals in which corresponding significant instants occur at the same rate, any variations in rate being constrained within specified limits. Note: Corresponding significant instants are separated by time intervals having durations which may vary without limit. A multiplexing scheme of bit stuffing and byte interleaving. It multiplexes the minimum rate 64 kit/s into the 2 Mbit/s, 34 Mbit/s, 140 Mbit/s, and 565 Mbit/s rates.
Issue 01 (2011-06-30)
137
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
PLL Pointer
Phase-Locked Loop An indicator whose value defines the frame offset of a virtual container with respect to the frame reference of the transport entity on which this pointer is supported. Packet Over SDH A direct current power distribution box at the upper part of a cabinet, which supplies power for the subracks in the cabinet. A unit that performs AC or DC power distribution. Point-to-Point Protocol See Pseudo Random Binary Sequence Primary Reference Clock In the hierarchy of signaling system No.7, when the upper layer applies for services from the lower layer or the lower layer transmits services to the upper layer, the data is exchanged between the user and the service provider. The data transmitted between adjacent layers is called primitive. A line, such as a subscriber cable and trunk cable, which are leased by the telecommunication carrier and are used to meet the special user requirements. A specific path that is part of a protection group and is labeled protection. A specific service that is part of a protection group and is labeled protection. In the NMS, the protection subnet becomes a concept of network level other than multiplex section rings or path protection rings. The protection sub-network involves NEs and fiber cable connections. The user interface, of the NMS, which is used to manage protection in the network. A device that is located in the backbone network of the MPLS VPN structure. A PE is responsible for managing VPN users, establishing LSPs between PEs, and exchanging routing information between sites of the same VPN. A PE performs the mapping and forwarding of packets between the private network and the public channel. A PE can be a UPE, an SPE, or an NPE. Packet Switched Power Spectral Density A sequence that is random in a sense that the value of an element is independent of the values of any of the other elements, similar to real random sequences.
POS Powe r box Powe r distribution unit PPP PRBS PRC Primitive
Private Line
Issue 01 (2011-06-30)
138
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Pseudo Wire
An emulated connection between two PEs for transmitting frames. The PW is established and maintained by PEs through signaling protocols. The status information of a PW is maintained by the two end PEs of a PW. An end-to-end Layer 2 transmission technology. It emulates the essential attributes of a telecommunication service such as ATM, FR or Ethernet in a packet switched network (PSN). PWE3 also emulates the essential attributes of low speed time division multiplexing (TDM) circuit and SONET/SDH. The simulation approximates to the real situation. See Permanent Virtual Connection See Pseudo Wire See Pseudo Sire Emulation edge-to-edge
PVC PW PWE3
A.17 Q
QinQ A layer 2 tunnel protocol based on IEEE 802.1Q encapsulation. It add a public VLAN tag to a frame with a private VLAN tag to allow the frame with double VLAN tags to be transmitted over the service providers backbone network based on the public VLAN tag. This provides a layer 2 VPN tunnel for customers and enables transparent transmission of packets over private VLANs. See Quality of Service A commonly-used performance indicator of a telecommunication system or channel. Depending on the specific system and service, it may relate to jitter, delay, packet loss ratio, bit error ratio, and signal-to-noise ratio. It functions to measure the quality of the transmission system and the effectiveness of the services, as well as the capability of a service provider to meet the demands of users.
A.18 R
Rapid Spanning Tree Protocol RDI Re ceiver Sensitivity Re ference clock REG Regeneration An evolution of the Spanning Tree Protocol, providing for faster spanning tree convergence after a topology change. The RSTP protocol is backward compatible with the STP protocol. Remote Defect Indication The minimum acceptable value of average received power at point R to achieve a 1 x 10 -12 BER (The FEC is open). A kind of stable and high-precision autonous clock providing frequencies for other clocks for reference. A piece of equipment or device that regenerates electrical signals. The process of receiving and reconstructing a digital signal so that the amplitudes, waveforms and timing of its signal elements are constrained within specified limits.
Issue 01 (2011-06-30)
139
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Regenerator section overhead Remote optical pumping amplifier Resilient Packet Ring RF RFA RFI ring network RNC ROPA route
The regenerator section overhead comprises rows 1 to 3 of the SOH of the STM-N signal. A remote optical amplifier subsystem designed for applications where power supply and monitoring systems are unavailable. The ROPA subsystem is a power compensation solution to the ultra-long distance long hop (LHP) transmission. A network topology being developed as a new standard for fiber optic rings. Radio Frequency Request For Announcement Request for Information A type of network topology in which each node connects to exactly two other nodes, forming a circular pathway for signals. Radio Network Controller See Remote optical pumping amplifier The path that network traffic takes from its source to its destination. In a TCP/IP network, each IP packet is routed independently. Routes can change dynamically. A device on the network layer that selects routes in the network. The router selects the optimal route according to the destination address of the received packet through a network and forwards the packet to the next router. The last router is responsible for sending the packet to the destination host. Can be used to connect a LAN to a LAN, a WAN to a WAN, or a LAN to the Internet. Rendezvous Point See Resilient Packet Ring A asynchronous transfer mode that does not involve hand-shaking signal. It can communicate with RS232 and RS422 of other stations in point-to-point mode and the transmission is transparent. Its highest speed is 19.2kbit/s. The specification that defines the electrical characteristics of balanced voltage digital interface circuits. The interface can change to RS232 via the hardware jumper and others are the same as RS232. See Rapid Spanning Tree Protocol Radio Transmission Node Receiver
route r
RP RPR RS232
RS422
RSTP RTN RX
Issue 01 (2011-06-30)
140
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
A.19 S
S1 byte A byte to transmit network synchronization status information. On an SDH network, each NE traces hop by hop to the same clock reference source through a specific clock synchronization path, realizing synchronization on the entire network. If a clock reference source traced by an NE is missing, this NE will trace another clock reference source of a lower level. To implement protection switching of clocks in the whole network, the NE must learn about clock quality information of the clock reference source it traces. Therefore, ITU-T defines S1 byte to transmit network synchronization status information. It uses the lower four bits of the multiplex section overhead S1 byte to indicate 16 types of synchronization quality grades. Auto protection switching of clocks in a synchronous network can be implemented using S1 byte and a proper switching protocol. Storage Area Network Square Connector Sustainable Cell Rate See space diversity See Signal Degrade See Standard definition See Synchronous Digital Hierarchy Serious Disturbance Period See Standard definition-Serial Digital Interface signal SDH Equipment Clock The portion of a SONET transmission facility, including terminating points, between (i) a terminal network element and a regenerator or (ii) two regenerators. A terminating point is the point after signal regeneration at which performance monitoring is (or may be) done. A function of establishing a replacement connection by network without the network management connection function. When a connection failure occurs, the replacement connection is found by the network elements and rerouted depending on network resources available at that time. The ECC channel realized by means of serial port. A network device that provides services to network users by managing shared resources, often used in the context of a client-server architecture for a LAN. A measure that ensures that the services can be received at the receive end. Severely Errored Second Synchronous Equipment Timing Source
Self-healing
Issue 01 (2011-06-30)
141
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
settings SF Signal Fail SFP SHDSL Side Mode Suppression Ratio signal cable Signal Degrade Signal Fail Simple Network Management Protocol
Parameters of a system or operation that can be selected by the user. See Signal Fail A signal indicating that associated data has failed in the sense that a near-end defect condition (non-degrade defect) is active. See Small Form-Factor Pluggable Single-line High speed Digital Subscriber Line The Side Mode Suppression Ratio (SMSR) is the ratio of the largest peak of the total source spectrum to the second largest peak. Common signal cables cover the E1 cable, network cable, and other non-subscriber signal cable. SD is a signal indicating the associated data has degraded in the sense that a degraded defect (e.g., dDEG) condition is active. SF is a signal indicating the associated data has failed in the sense that a near-end defect condition (not being the degraded defect) is active. A network management protocol of T CP/IP. It enables remote users to view and modify the management information of a network element. This protocol ensures the transmission of management information between any two points. The polling mechanism is adopted to provide basic function sets. According to SNMP, agents, which can be hardware as well as software, can monitor the activities of various devices on the network and report these activities to the network console workstation. Control information about each device is maintained by a management information block. Angle-bars on which shelves and chassis may slide and be supported within a cabinet or shelf. A specification for a new generation of optical modular transceivers.
slide rail Small Form-Factor Pluggable SMSR SNC SNCMP SNCP SNCP node
See Side Mode Suppression Ratio SubNetwork Connection See Subnetwork connection multipath protection See SubNetwork Connection Protection Set the SNC node on the protection sub-network to support sub-network connection protection that spans protection sub-networks. The SNCP node of the ring sub-network can support electric circuit dually feed and selectively receive a timeslot out of the ring, thus implementing sub-network connection protection. The SNCP node is generally set on the node on the line board with the path protection type of the dual fed and selectively received. See Subnetwork Connection T unnel Protection See Simple Network Management Protocol
SNCTP SNMP
Issue 01 (2011-06-30)
142
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Signal Noise Ratio A diversity scheme that enables two or more antennas separated by a specific distance to transmit/receive the same signal and selection is then performed between the two signals to ease the impact of fading. Currently, only receive SD is used. STP is a protocol that is used in the LAN to remove the loop. STP applies to the redundant network to block some undesirable redundant paths through certain algorithms and prune a loop network into a loop-free tree network. Synchronous Physical Interface See Synchronization Status Message Synchronization Supply Unit A video format with the resolution below 720p. Standard definition video signal transported by serial digital interface.
SPI SSM SSU Standard definition Standard definition-Serial Digital Inte rface signal Statistical multiplexing
A multiplexing technique whereby information from multiple logical channels can be transmitted across a single physical channel. It dynamically allocates bandwidth only to active input channels, to make better use of available bandwidth and allow more devices to be connected than with other multiplexing techniques. SDH standard for transmission over optical fiber at 622.08 Mbit/s. See Spanning Tree Protocol A number used to differentiate network sections in a sub-network conference. A sub-network ID consists of the first several digits (one or two) of a user phone number. An order wire phone number consists of the sub-network ID and the user number. A type of smaller networks that form a larger network according to a rule, for example, according to different districts. This facilitates the management of the large network. The technique used by the IP protocol to determine which network segment packets are destined for. The subnet mask is a binary pattern that is stored in the client machine, server or router matches with the IP address. The only difference is that SNCP is of 1+1 protection and SNCMP is of N+1 protection. That is, several backup channels protect one active channel in SNCMP. A function, which allows a working subnetwork connection to be replaced by a protection subnetwork connection if the working subnetwork connection fails, or if its performance falls below a required level.
subnet
subnet mask
Issue 01 (2011-06-30)
143
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
SNCTP provides a VC-4 level channel protection. When the working channel is faulty, the services of the entire VC-4 path can be switched over to the protection channel. A part used to support and fix a cabinet on the antistatic floor. It is made of welded steel plates and is used to block up the cabinets to facilitate floor layout and cabling. Before the whole set of equipment is grounded, insulation plates must be installed under the supports, and insulating coverings must be added to the expansion bolts to achieve good insulation performance. An attribute set to determine whether an NE monitors the alarm. Under suppression status, NE will not monitor the corresponding alarm conditions and the alarm will not occur even when the alarm conditions are met. Switching Virtual Connection A priority of a board that is defined for protection switching. When several protected boards need to be switched, a switching priority should be set for each board. If the switching priorities of the boards are the same, services on the board that fails later cannot be switched. Services on the board with higher priority can preempt the switching resources of that with lower priority. It refers to the period of time between the start of detecting and the moment when the line is switched back to the original status after protection switching occurs in the MSP sub-network. A message that carries quality levels of timing signals on a synchronous timing link. Nodes on an SDH network and a synchronization network acquire upstream clock information through this message. Then the nodes can perform proper operations on their clocks, such as tracing, switching, or converting to holdoff, and forward the synchronization information to downstream nodes. A transmission scheme that follows ITU-T G.707, G.708, and G.709. It defines the transmission features of digital signals such as frame structure, multiplexing mode, transmission rate level, and interface code. SDH is an important part of ISDN and B-ISDN. It interleaves the bytes of low-speed signals to multiplex the signals to high-speed counterparts, and the line coding of scrambling is used only for signals. SDH is suitable for the fiber communication system with high speed and a large capacity since it uses synchronous multiplexing and flexible mapping structure. A clock providing timing services to connected network elements. This would include clocks conforming to Recommendations G.811, G.812 and G.813.
Suppression state
Synchronous source
Issue 01 (2011-06-30)
144
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
A.20 T
Tandem Connection Monitor TCM TCP/IP TDM TIM Timeslot Time Synchronization TM TMN ToS TPS Trail management function In the SDH transport hierarchy, the TCM is located between the AU/TU management layer and HP/LP layer. It uses the N1/N2 byte of POH overhead to monitor the quality of the transport channels on a transmission section (TCM section). See T andem Connection Monitor See T ransmission Control Protocol/Internet Protocol Time Division Multiplexing Trace Identifier Mismatch Continuously repeating interval of time or a time period in which two devices are able to interconnect. Also called the moment synchronization, time synchronization means that the synchronization of the absolute time, which requires that the starting time of the signals keeps consistent with the UTC time. Terminal Multiplexer Telecommunications Management Network See Type of Service See T ributary Protection Switch A network level management function of the network management system. This function enables you to configure end-to-end services, view graphic interface and visual routes of a trail, query detailed information of a trail, filter, search and locate a trail quickly, manage and maintain trails in a centralized manner, manage alarms and performance data by trail, and print a trail report. A transmitter and receiver housed together in a single unit and having some circuits in common, often for portable or mobile use. Common name for the suite of protocols developed to support the construction of worldwide internetworks.
Transceive r Transmission Control Protocol/Inte rnet Protocol transparent transmission Tray Tributary loopback Tributary Protection Switch
A process during which the signaling protocol or data is not processed in the content but encapsulated in the format for the processing of the next phase. A component that can be installed in the cabinet for holding chassis or other devices. A fault can be located for each service path by performing loopback to each path of the tributary board. There are three kinds of loopback modes: no loopback, outloop, and inloop. A function that uses a standby tributary processing board to protect N tributary processing boards.
Issue 01 (2011-06-30)
145
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Tributary unit
An information structure which provides adaptation between the lower order path layer and the higher order path layer. It consists of an information payload (the lower order VC) and a TU pointer which indicates the offset of the payload frame start relative to the higher order VC frame start. One or more Tributary Units, occupying fixed, defined positions in a higher order VC-n payload is termed a Tributary Unit Group (TUG). TUGs are defined in such a way that mixed capacity payloads made up of different size Tributary Units can be constructed to increase flexibility of the transport network. Time To Live Tributary Unit See T ributary Unit Group A channel on the packet switching network that transmits service traffic between PEs. In VPN, a tunnel is an information transmission channel between two entities. The tunnel ensures secure and transparent transmission of VPN information. In most cases, a tunnel is an MPLS tunnel. A field in an IP packet (IP datagram) used for quality of service (QoS). The TOS field has 8 bits in length, which is divided into five subfields.
Type of Service
A.21 U
UART UAS UBR underfloor cabling UNI Unprotecte d Universal Asynchronous Receiver/Transmitter Unavailable Second Unspecified Bit Rate The cables connected cabinets and other devices are routed underfloor. See User-to-Network Interface Pertaining to the transmission of the services that are not protected. The services cannot be switched to the protection channel if the working channel is faulty or the service is interrupted, because protection mechanism is not configured. A sub-network without any protection mechanism. The purpose of such configuration is to provide the basic data of trail protection for subsequent trail management. An operation to report some or all configuration data of an NE to the NMS. The configuration data then covers the configuration data stored at the NMS side. Uninterruptible Power Module TThe critical value that can induce unexpected events if exceeded. Uninterruptible Power Supply
Issue 01 (2011-06-30)
146
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
Cables or fibers connect the cabinet with other equipment from the top of the cabinet. Any entity external to the network which utilizes connections through the network for communication. A person or other entity authorized by a subscriber to use some or all of the services subscribed to by that subscriber. The interface between user equipment and private or public network equipment (for example, ATM switches). Universal T ime Coordinated
A.22 V
VB VBR VC VC VCG VCI Virtual Container Virtual Bridge Variable Bit Rate Virtual Concatenation See Virtual Container Virtual Concatenation Group Virtual Channel Identifier The information structure used to support path layer connections in the SDH. It consists of information payload and path overhead (POH) information fields organized in a block frame structure which repeats every 125 or 500 s. A logical grouping of two or more nodes which are not necessarily on the same physical network segment but which share the same IP network number. This is often associated with switched Ethernet. A system configuration, where the subscriber is able to build a private network via connections to different network switches that may include private network capabilities. See Virtual local area network Virtual Path Virtual Path Identifier See Virtual Private Network
Virtual local area network Virtual Private Ne twork VLAN VP VPI VPN
A.23 W
Wait to Restore WAN Wande r The number of minutes to wait before services are switched back to the working line. Wide Area Network The long-term variations of the significant instants of a digital signal from their ideal position in time (where long-term implies that these variations are of frequency less than 10 Hz).
Issue 01 (2011-06-30)
147
OptiX OSN 550 Multi-Service CPE Optical Transmission System Product Description
A washer is a thin flat ring of metal or rubber which is placed over a bolt before the nut is screwed on. A technology that utilizes the characteristics of broad bandwidth and low attenuation of single mode optical fiber, uses multiple wavelengths as carriers, and allows multiple channels to transmit simultaneously in a single fiber. Data for describing the wavelength protection structure. Its function is similar to that of the protection subnet for SDH NEs. The wavelength path protection can work only with the correct configuration of the wavelength protection group. See Wavelength Division Multiplexing Weighted Fair Queuing A tool for fiber routing, which acts as the corrugated pipe. A path allocated to transport the normal traffic. Weighted Random Early Detection See Wait to Restore
Issue 01 (2011-06-30)
148