Agilent 7890A Gas Chromatograph
Agilent 7890A Gas Chromatograph
Agilent 7890A Gas Chromatograph
All the elements for perfect chemistry. Our measure is your success.
The new Agilent 7890A Gas Chromatograph brings important new separation capabilities and productivity features to the industryleading Agilent GC platform.
2 To learn more about the Agilent 7890A GC, visit www.agilent.com/chem/7890A. Or call toll-free, 800-227-9770 (U.S. and Canada).
Higher Productivity
Faster oven cool down, robust backflush capability, advanced automation features and faster GC/MS oven ramps let you get more done in less time, at the lowest possible cost per sampleall easily incorporated into your existing method.
Easier Operation
Powerful, chromatographer-friendly software simplifies method setup and system operation, and minimizes training time. Practical, time-saving design features speed up and simplify routine maintenance.
Configure the exact system to meet your labs needs today, and easily adapt to changing application and throughput requirements. Page 12
4 To learn more about the Agilent 7890A GC, visit www.agilent.com/chem/7890A. Or call toll-free, 800-227-9770 (U.S. and Canada).
6.624 6.619
6.641
0.97 psi
0.967 psi
0.96 psi
5th-generation EPC and advanced digital electronics set a new benchmark in pressure setpoint precision (to 0.001 psi)improving RTL precision for very-low-pressure applications.
Full electronic pneumatics control makes it fast and easy to set all pressures and flows. Our 5th-generation EPC and digital electronics keep these setpoints constant from run to run, providing superior retention time repeatability.
Not only is one ensured unsurpassed retention time reproducibility in standard applications, but also in multi-dimensional applications such as the heart-cutting example shown here.
Add extra dimensions to your chromatography with Agilent Capillary Flow Technology.
Agilents proprietary Capillary Flow Technology solves a problem chromatographers have been wrestling with for decades: How to make reliable, leak-free capillary connections that can stand up to the temperature extremes of a modern GC oven. These inert, low-mass, low-dead volume devices not only make it easy to make secure connections; they give you the ability to precisely divert your gas flow pneumatically, where and when you want. This opens the door to highly useful techniques that can improve your analytical results, as well as saving time and resources. For example:
Deans Switch
The idea of fluidic switching between two columns, or redirecting effluent, has been around almost since the beginning of GC. But before Capillary Flow Technology, the implementation hasnt been reliable enough for routine use in a GC oven. Deans switching enables two-dimensional GC (heart-cutting) for analysis of trace compounds in complex samples. Flow redirection can also reduce maintenance costs by protecting detectors or columns.
Cut
Automatic Liquid Sampler
QuickSwap
Heres an elegant answer to a common GC/MS problem: Waiting around for a mass spectrometer to vent before you can change out a column or perform routine inlet maintenance. Using a simple, inexpensive QuickSwap device, you can safely disconnect the column without venting, and without losing vacuumin about 30 seconds!
7890A GC
FID1
FID2
Column 1
Column 2
Deans Switch
In this example, the Capillary Flow Deans Switch provides additional selectivity that enables the analysis of unresolved trace components by heart-cutting onto another column having a different stationary phase.
6 To learn more about the Agilent 7890A GC, visit www.agilent.com/chem/7890A. Or call toll-free, 800-227-9770 (U.S. and Canada).
Flow Splitting
Flow splittingsending the sample to multiple detectorscan provide the most information from a sample in a single run, and is especially valuable for analyzing compounds in complex matrices. This technique can help you locate peaks of interest faster, get better integration of target peaks and have higher overall confidence in identifying unknowns.
Strawberry Extract Highlighting Unknowns
TIC
By reversing column flow immediately after the last compound of interest has eluted, you can eliminate long bake-out times for highly retained sample components. Instead, these materials are swept backwards through the column and out the split vent, preventing carryover, contamination, retention time shifts, and MSD source contamination.
Response 1800000 1700000 1600000 1500000 1400000 1300000 1200000 1100000 1000000 900000 800000 700000 600000 500000 400000 300000 200000 Time 5.00 10.00 15.00 20.00
Backflush Region
ECD
FPD (P)
25.00
30.00
35.00
40.00
10
15
20
25
30
Response 1800000 1700000 1600000 1500000 1400000 1300000 1200000 1100000 1000000 900000 800000 700000 600000 500000 400000 300000 200000 Time 5.00 10.00 15.00
Backflushing
Backflushing is an extremely valuable technique that can be implemented with any purged Agilent Capillary Flow device. It can improve the quality of your analysis and save you time and money on every runand as backflush occurs post-run, you dont have to change method conditions for the time during the chromatographic run.
20.00
25.00
30.00
35.00
40.00
ECD
DFPD (P)
5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00
It took additional 33 mins and column to 320OC to remove these high boilers.
Run stopped at 42 min and backflushed at 280OC for 7 mins. Blank run after backflush showing the column was clean.
10
15
20
25
30
35
40
45
50
55
60
65
70
min
Impurities in Hydrocarbons
Ethylene analysis uses 2D GC to combine measurement by ASTM D6159 with a trace analysis of methanol.
This application takes advantage of Agilents Capillary Flow Deans Switch device and the new Back Pressure Regulation (BPR) mode of the 7890A GCs Pneumatic Control Module to improve sensitivity and resolution. Dynamic blending systems make multi-level calibrations of gas samples easy and routine.
2-GC Separation of Oxygenates and Hyrocarbon 2-GC Separation of Oxygenates and Hydrocarbon Impuritiesin Ethylene inin a Single Run Impurities in Ethylene a Single Run
............................................... ...............................................
......
......
10
15
20
25 Min.
10
15
20
25
Min.
8 To learn more about the Agilent 7890A GC, visit www.agilent.com/chem/7890A. Or call toll-free, 800-227-9770 (U.S. and Canada).
TIC Scan
NPD
SIM-ion 245
1 2 3 4 5 6 7 8
With the 7890A GC, all of our data systems provide the same level of support
Whether youre using the GC ChemStation, GC/MSD ChemStation, EZChrom Elite or the enterprise-wide Agilent OL system, you can be confident of complete support for your 7890A GC. Just as with our earlier 6890 hardware platform, each of these systems offers the same ease of use for 7890A method developmentand fully supports Lab Monitor & Diagnostic Software, as well as productivity improvement with ALS overlap and backflush.
10 To learn more about the Agilent 7890A GC, visit www.agilent.com/chem/7890A. Or call toll-free, 800-227-9770 (U.S. and Canada).
Lab Monitor & Diagnostic Software maximizes uptime by heading off problems before they happen.
Agilents innovative Lab Monitor & Diagnostic Software continuously monitors a single or multiple Agilent GC and GC/MSD systems in real time to alert you to GC maintenance needs and instrument problemsbefore your results go bad. The software also keeps track of injections, hours of operation and other user-specified parameters, and lets you know when its time to change out consumables or perform basic upkeep tasks, via popup, email or phone text message. It also makes it quick and easy to perform automated diagnostic routines that help to verify proper instrument performance.
Lab-at-a-Glance feature lets you view the operational status and maintenance needs of a single system or multiple systems lab-wide.
Is it time to change columns or inlet liners? Resource counters and progress bars provide instant visual indication of preventive maintenance needs. So you can be sure youre getting maximum usage from all your consumables.
It even keeps an eye on the results. You can also have the software alert you to perform inlet and/or column maintenance when specified chromatographic attributes fall outside preset windowswithout the need for subjective interpretation or the intervention of a highly skilled chemist.
11
Ready for anything your lab can throw at it. Including the future.
The modular, fully automated Agilent 7890A GC system includes the industrys widest selection of inlets, detectors, columns, consumables and sample introduction choices in fact, everything you need to keep your lab up and running at peak productivity.
Hidden Anode
Looking for the perfect productivity partner for your Agilent 7890A GC?
Add an Agilent 7683 Series Automatic Liquid Sampler. Offering the fastest injection times of any GC autosampler, greater solvent capacity, multiple sampling options, dual simultaneous injection and more, the 7683 ALS is ready to go to work.
Hardstop
12 To learn more about the Agilent 7890A GC, visit www.agilent.com/chem/7890A. Or call toll-free, 800-227-9770 (U.S. and Canada).
High performance Agilent J&W GC columns and supplies to meet every analytical need.
Agilent GC consumables, including our J&W columns, are designed, manufactured and packaged to deliver maximum productivity from your Agilent GC and GC/MSD systems. We strive to provide you with the cleanest, most inert flow path. From our proprietary deactivated inlet liners to our injection-molded inlet gold seal, through the J&W lowbleed columns, your samples are protected from exposure to active sites or outgassed contaminants that can alter your results.
13
High-sensitivity detectors for every sample type Widest selection of inlets to optimize your separations
Split/splitless (SSL) capillary Packed purged injection port (PPIP) Cool on-column (COC) Cool on-column with solvent vapor exit (COC-SVE) Programmable temperature vaporizing (PTV) Volatiles interface (VI) High temperature PTV High pressure gas sample injection LPG direct* Temperature-programmable precolumn* Mass selective (Agilent 5975 Series MSD) Flame ionization (FID) Thermal conductivity (TCD) Micro-electron capture (micro-ECD) Flame photometric, single- or dual-wavelength (FPD) Nitrogen-phosphorus (NPD) Sulfur chemiluminescence (SCD) Nitrogen chemiluminescence (NCD) Atomic emission (AED)* Pulsed flame photometric (PFPD)* Photoionization (PID)* Electrolytic conductivity (ELCD)* Discharge ionization (DID)*
*Available through Agilent Channel Partners Contact Agilent for other custom configurations. A wide variety of additional solutions are available via Agilents channel partners.
14 To learn more about the Agilent 7890A GC, visit www.agilent.com/chem/7890A. Or call toll-free, 800-227-9770 (U.S. and Canada).
15
Research use only. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Agilent Technologies, Inc. 2007 Printed in USA March 16, 2007 5989-5929EN