CoDeSys Visu V23 E
CoDeSys Visu V23 E
CoDeSys Visu V23 E
Supplement to the User Manual for PLC Programming with CoDeSys 2.3
Copyright 2003, 2004, 2005, 2006, 2007 by 3S - Smart Software Solutions GmbH All rights reserved.
We have gone to great lengths to ensure this documentation is correct and complete. However, since it is not possible to produce an absolutely error-free text, please feel free to send us your hints and suggestions for improving it.
Trademark Intel is a registered trademark and 80286, 80386, 80486, Pentium are trademarks of Intel Corporation. Microsoft, MS, MS-DOS and Intellisense are registered trademarks, Windows is a trademark of Microsoft Corporation.
Publisher 3S - Smart Software Solutions GmbH Memminger Strae 151 DE-87439 Kempten Tel. +49 831 5 40 31 - 0 Fax +49 831 5 40 31 50
Content
Table of Content
1 Advantages of an integrated visualization 2 The Visualization Editor in CoDeSys 2.1 2.2 2.3 2.4 2.4.1 2.4.2 2.4.3 1-1 2-1
Create a new Visualization ................................................................................ 2-2 Visualization Elements, Insert............................................................................ 2-2 Positioning of Visualization Elements... ............................................................. 2-6 Visualization, Configure - Overview ................................................................... 2-9 Visualization Elements, Configure... .................................................................. 2-10 Visualization Object, Configure.......................................................................... 2-53 Image files in the visualization ........................................................................... 2-57 3-1
Static language switching .................................................................................. 3-1 Dynamic Language switching ............................................................................ 3-3 Configuration...................................................................................................... 3-3 XML-File for Dynamic Texts............................................................................... 3-4 Calling up language-dependent Online Help via a visualization element .......... 3-8 4-1 5-1
Overview ............................................................................................................ 5-1 Operation over the keyboard - in online mode................................................... 5-1 'File' 'Print' in online mode.................................................................................. 5-2 Access Protection in multi-client operation ........................................................ 5-2 6-1 7-3
Preconditions ..................................................................................................... 8-1 Status check, Auto-Reload, File error_ini.xml.................................................... 8-1 Editing the WebVisu.htm file .............................................................................. 8-2 Preparing a Web-Visualization in CoDeSys....................................................... 8-4 Configuration and Start of the Web Server ........................................................ 8-4 Calling a Web-Visualization via Internet ............................................................ 8-6 Restrictions and Special Features ..................................................................... 8-7 9-1
Preconditions ..................................................................................................... 9-1 Creating a Target-Visualization.......................................................................... 9-1 Starting the Target-Visualization........................................................................ 9-4 Scan of mouse-clicks and dynamic texts ........................................................... 9-4 Restrictions ........................................................................................................ 9-5 10-1
CoDeSys Visualization
Content
Implicit Variables in the Visualization Example Dll for ActiveX Control Possible Key Combinations
ii
CoDeSys Visualization
XML WebVisualisierung
ST-Code TargetVisualisierung
2. CoDeSys HMI The program CoDeSys HMI, which displays visualizations on a PC without the complete development user interface, also communicates via the programming interface. The configuration of OPC (OPC OLE for Process Control) resp. DDE (DDE Dynamic Data Exchange) interface is not necessary. See chapter7. 3. Web-Visualization Optionally CoDeSys generates a description in XML format from the visualization data, which is loaded to the controller together with a Java-Applet (Applet a program developed in the programming language JAVA, which can be processed by browsers) and which can be displayed via TCP/IP on a browser. Thus the visualization data are available online on various platforms. See chapter 8.
CoDeSys Visualization
1-1
4. Target-Visualization For controllers with integrated display the visualization data can be loaded from the programming system together with the application to the target system. There they get displayed automatically. This solution can be portated with low effort to any devices which are programmable with CoDeSys. See chapter 9. Overview on the functions:
Elements
Rectangle, Ellipse, Rounded rectangle Line, Polygon, Polyline, Curve Bitmap, WMF-file ActiveX Control Button, Table, Histogram, Bar Display, Meter Reference to another visualization (instance) Text display Color changes Visible/Invisible Shift Rotation Scaling Offset on the particular edges of an object (for Bar Display) Button activ/inactiv Current line (only text display) Toggle/tap Boolean value Text input Change of visualization Special actions (Leave visualization, Read/Write receipts, Switch language, call external EXE etc.) Choose line (only text display) Switching language Tooltips for all elements ASCII Import/Export Background Bitmap Master layout Automatic Scaling Drawing operations: Alignment, Order, Grouping Placeholder concept for creating objects with complex graphic elements Programmed visualization expressions
Input possibilities:
Further properties
1-2
CoDeSys Visualization
CoDeSys Visualization
2-1
2.1
2.2
'Bitmap',
'Visualization',
'Button',
'ActiveX-Element',
'Meter', 'Bar Display', 'Histogram', 'Alarm table', 'Trend', 'WMF file'. A check appears in front of the selected command. You can also use the tool bar. The selected element appears pushed down(e.g. ).
If you now go to the editor window with the mouse, you will see that the mouse pointer is identified with the corresponding symbol (e.g. ). Click on the desired starting point of your element and move the pointer with pressed left mouse key until the element has the desired dimensions.
2-2
CoDeSys Visualization
If you want to create a polygon or a line, first click with the mouse on the position of the first corner of the polygon resp. on the starting point of the line, and then click on the further desired corner points. By doubleclicking on the last corner point you will close the polygon and it will be completely drawn respectively the line will be completed. If you want to create a curve (Bezier curves) determine the initial and two other points with mouse clicks to define the circumscribing rectangle. An arc is drawn after the third mouse click. You can then change the position of the end point of the arc by moving the mouse and can then end the process with a double click or add another arc with additional mouse clicks. Furthermore pay attention, to the status bar and the change from select and insert modes. Regard also the possibility of using placeholders and Master layouts. 'Insert' 'Rectangle' Symbol: With the command you can insert a rectangle as an element into your present visualization (see chapter 2.2). 'Insert' 'Rounded Rectangle' Symbol: With the command you can insert a rectangle with rounded corners as an element in your present visualization (see chapter 2.2). 'Insert' 'Ellipse' Symbol: With the command you can insert a circle or an ellipse as an element in your present visualization visualization (see chapter 2.2). 'Insert' 'Polygon' Symbol: With the command you can insert a polygon as an element in your present visualization (see chapter 2.2). 'Insert' 'Polyline' Symbol: With the command you can insert a line as an element into your current visualization (see chapter 2.2). 'Insert' 'Curve' Symbol: With the command you can insert a Bezier curve as an element into your current visualization (see chapter 2.2). 'Insert' 'Pie' Symbol: Use this command to insert a Pie Segment as an element into your current visualization.
CoDeSys Visualization
2-3
While pressing the left mouse button, bring up an area in the desired size. An oval element including a line marking the radius at the 0 position will be displayed. As long as keeping the mouse button pressed you can immediately change size and position of the element by moving the mouse. A little black square is attended to the element, indicating the corner of a virtual rectangle surrounding the element. In order to define the start and end angles of a Pie, select the end point of the radius line on the circular arc by a mouse-click. As soon as you, keeping the mouse button pressed, move the cursor, two small rectangles will be displayed, indicating the two angle positions. As from now those can be selected and moved separately. If you want the angle values get defined dynamically by variables, open the configuration dialog category 'Angle' and enter the desired variable names. You can resize or reshape the element later by either clicking on the centre point, the cursor getting displayed as diagonally crossed arrows, and moving the mouse while keeping the mouse button pressed (or using the arrow keys). Alternatively you can select and move the corner indicating little square outside of the element. In order to move the element to another position, click inside the element to get the cursor being displayed as vertically crossed arrows and then move the cursor. 'Insert' 'Bitmap' Symbol: With the command you can insert a bitmap as an element in your present visualization. (Use, see Visualization Elements, Insert). While pressing the left mouse button, bring up an area in the desired size. The standard dialog box for browsing for a file will be opened. You can use this dialog to select and enter a bitmap file from the local file system. In the configuration dialog of the inserted bitmap you then can define, whether a link to the bitmap file should be stored or the bitmap should be inserted as an element. Alternatively you can specify a project variable to define which bitmap should be used. This allows a dynamic change of bitmaps in online mode. The variable must be entered in the configuration dialog of an already inserted bitmap element and it must contain the name of a bitmap file managed in the project-global bitmap list. For a description on the configuration of a bitmap element please see 2.4.1, category Bitmap. 'Insert' 'Visualization' Symbol: With the command you can insert an existing visualization as an element in your present visualization. (Use, see Visualization Elements, Insert). While pressing the left mouse button, bring up an area in the desired size. A selection list of existing visualizations opens. After you have selected the desired visualization, it will be inserted in the defined area. An inserted visualization will also be named as an instance. 'Insert' 'Button' Symbol: This command is used to insert a button into your current visualization. (Use, see Visualization Elements, Insert). Drag the element to the desired size with the left mouse button held down. If a toggle variable is configured for the button it displays the state of this variable by visually displaying whether it is pressed or not pressed. Conversely, the variable is toggled by pressing" the button. Like for a "Bitmap element also for the filling of a button element an image file can be specified (static or dynamic use). See the description of the configuration dialog for category Bitmap(Kap.2.4.1).
2-4
CoDeSys Visualization
'Insert' 'WMF file' Symbol: This command is used to insert a Windows Metafile. The standard dialog for opening a file will appear, where you can select a file (extension *.wmf). After having closed the dialog with OK the file will be inserted as an element in the visualization. Please regard, that no link to a file will be saved, like it is done when you insert a bitmap, but the elements of the metafile will be inserted as a group. 'Insert' 'Table' Symbol: Use this command to insert a Table element as an element into your current visualization. It is used to display the current values of the elements of an array. While pressing the left mouse button, bring up an area in the desired size. Before the element gets displayed the configuration dialog 'Configure table'' will be opened. Here you will find additionally to the standard categories Tooltip and Security the categories 'Table', 'Columns', 'Rows' and 'Selection' where you can define contents and appearance of the table. 'Insert' 'ActiveX-Element' Symbol: Use this command to insert an ActiveX Control into your current visualization. It can be used later on Windows32 systems in CoDeSys HMI and the CoDeSys Target-Visualization. While pressing the left mouse button, bring up an area in the desired size. It will be inserted as a rectangle with the inscription "Control:". To select a certain ActiveX-Control and to configure the method calls and the display open the dialog 'Configure ActiveX-Control' by a double-click on the element resp. via command 'Extras' 'Configure' (see Chapter 2.4.1, ActiveX-Element). 'Insert' 'Meter' Symbol: Use this command to insert a Meter as an element into your current visualization. It provides a scale which is defined as a sector of a circular arc, and a pointer element. While pressing the left mouse button, bring up an area in the desired size. Before the element gets displayed the configuration dialog Configure Meter will be opened. Here you can define various parameters concerning the display of the element and a preview is available to check the configuration before really inserting the element by confirming the dialog. 'Insert' 'Bar Display' Symbol: Use this command to insert a Bar Display element into your current visualization. It is used to visualize the value of the assigned variable by a bar indicating the value by its length along a horizontal scale. While pressing the left mouse button, bring up an area in the desired size. Before the element gets displayed the configuration dialog 'Configure bar display' will be opened. Here you can define various parameters concerning the display of the element and a preview is available to check the configuration before really inserting the element by confirming the dialog.
CoDeSys Visualization
2-5
'Insert' 'Histogram' Symbol: Use this command to insert a Histogram element into your current visualization. It is used to visualize the elements of an array by bars which are placed side by side each indicating the value of the element by its length. While pressing the left mouse button, bring up an area in the desired size. Before the element gets displayed the configuration dialog 'Configure Histogram' will be opened. Here you can define various parameters concerning the display of the element and a preview is available to check the configuration before really inserting the element by confirming the dialog. 'Insert' 'Alarm table' Symbol: Use this command to insert an alarm table into your current visualization object. While pressing the left mouse button, bring up an area in the desired size. Before the element gets displayed the configuration dialog 'Configure Alarm table' will open. Here you will find additionally to the standard categories Tooltip and Security the categories 'Alarmtable', 'Settings for sorting', 'Columns' and Settings for alarmtable' where you can define contents and appearance of the table. An alarm table can be used to visualize the alarms, which have been defined in the Alarm configuration of the project. 'Insert' 'Trend' Symbol: Use this command to insert a trend element into your current visualization object.. While pressing the left mouse button, bring up an area in the desired size. The configuration (axes, variables, history) is done in the configuration dialog 'Trend'. The trend element, also named oscilloscope element, is used to display variable values within a certain time period. It stores the data in a file on the client and displays them as a graph. As soon as a value changes, a new entry will be made in the file, showing date/time and the new value. The trend element is drawn transparently. So you can assign any desired background (bitmap, color).
2.3
Selecting Visualization Elements The selection mode is activated by default. In order to select an element, click with the mouse on the element. You can also select the first element of the elements list by pressing the <Tab> key and jump to the next by each further keystroke. If you press the <Tab> key while pressing the <Shift> key, you jump backwards in the order of the elements list. In order to select elements, which are placed one upon the other, first select the top level element by a mouse-click. Then do further mouse-clicks while the <Ctrl>+<Shift>-buttons are pressed, to reach the elements in the underlying levels . In order to mark multiple elements, press and hold the <Shift> key and click the corresponding elements, one after another; or, while holding down the left mouse button, pull a window over the elements to be selected. In order to select all the elements, use the 'Extras' 'Select All' command. In the element list (called by 'Extras' 'Element list') you can select an element in the visualization by selecting the respective line.
2-6
CoDeSys Visualization
Changing the Selection and Insert Mode After the insertion of a visualization element, there is an automatic change back into the selection mode. If you want to insert an additional element the same way, you can once again select the corresponding command in the menu or the symbol in the tool bar.
You can also quickly change between the selection mode and the insert mode by pressing the <Ctrl>key and the right mouse button simultaneously. In the insert mode, the corresponding symbol will also appear at the mouse pointer, and the name will also be indicated in black in the status bar. 'Extras' 'Select' This command is used to switch the selection mode on or off. This can also be achieved using the symbol 'Extras' 'Select All' This command allows you to select all visualization elements within the current visualization object. Copying Visual Elements One or more selected elements can be inserted with the 'Edit' 'Copy' command, the <Ctrl>+<C> key combination, or the corresponding copy symbol, and with 'Edit' 'Paste'. A further possibility is to select the elements and to again click in one of these elements with the <Ctrl> key held down. If you now hold the left mouse button down, you can separate the elements thus copied from the original. Modifying Visualization Elements You can select an element which has already been inserted by a mouse click on the element or by pressing the <tab> key. A small black square will appear at each corner of each of the elements, (with ellipses at the corners of the surrounding rectangle). Except in the case of polygons, lines or curves further squares appear in the middle of the element edges between the corner points. or by pressing the right mouse-key while holding down the key at the same time.
With a selected element, the turning point (balance point) is also displayed at the same time. You can then rotate the element around this point with a set motion/angle. The turning point is displayed as a small black circle with a white cross ( button. ). You can drag the turning point with a pressed left mouse
You can change the size of the element by clicking on one of the black squares and, while keeping the left mouse button pressed, controlling the new outline. With the selection of a polygon, you can drag each individual corner using the same technique. While doing this, if you press the <Ctrl>-key then an additional corner point will be inserted at the corner point, an additional corner point will be inserted, which can be dragged by moving the mouse. By pressing the <Shift>+<Ctrl>-key, you can remove a corner point. Dragging Visualization Elements One or more selected elements can be dragged by pressing the left mouse button or the arrow key. Grouping Elements Elements can be grouped by selecting all desired elements and performing the command 'Extras' 'Group'. The group will behave like a single element:
CoDeSys Visualization
2-7
the grouped elements get a collective frame; when dragging the frame, depending on the current configuration all elements will be stretched, compressed or keep their original size; only the group can be moved to another position. the grouped elements get collective properties: inputs only can effect the group and not a single element. Thus the elements also get one collective configuration dialog (category 'group'). The property 'Change color' can not be configured for a group! To redefine a single element of a group, the grouping must be redone by the command 'Extras' 'Ungroup'. The configuration of the group (see Chapter 2.4.1, Group) will be lost in this case.
Note: As soon as you save the project as CoDeSys Version 2.1 or lower, a group of visualization elements will be resolved automatically; that means that the elements of the group will be shown as single elements in the visualization.
'Extras' 'Send to Front' Use this command to bring selected visualization elements to the front. 'Extras' 'Send to Back' Use this command to send selected visualization elements to the back. 'Extras' 'Align' Use this command to align selected visualization elements. The following alignment options are available: Left: the left edge of each of the elements will be aligned to the element that is furthest to the left the same is true for Right / Top / Bottom Horizontal Center: each of the elements will be aligned to the average horizontal center of all elements Vertical Center: each of the elements will be aligned to the average vertical center of all elements 'Extras' 'Elementlist' This command opens a dialog box containing a list of all visualization elements including their number, type and position. The position is given according to the x and y position of the upper left (x1, y1) and the lower right (x2, y2) corner of the element. When one or more items have been selected, the corresponding elements in the visualization are marked for visual control and if necessary the display will scroll to that section of the visualization that contains the elements. Use the To front button to bring selected visualization elements to the front. Use the To behind button to move them to the back. Below the elements list there you find depending on which element is currently selected - one of the following combinations of edit fields where you can modify size and position of the element: If a rectangle, rounded rectangle, ellipse, bitmap, visualization, button or a meta file is currently selected, then next to the text "Rectangle (x1, y1, x2, y2)" there are four edit fields, where the actual x/y positions are shown and can be modified. If a line, polygon or a curve is currently selected, a table will be available showing the actual XPosition and Y-Position of each of the black squares which mark the shape of the element, as soon as it is selected. These values can be edited here.
2-8
CoDeSys Visualization
To set the modified position values in the elements list and in the visualization, press button Set rectangle (in case 1.) resp. Set polygon (in case 2.). Use the Delete button to remove selected visualization elements. Use the Undo and Redo buttons to undo or restore changes that have been made just as you would do with the commands 'Edit' 'Undo' and 'Edit' 'Redo' . In the dialog box, you can observe the changes that are being made. Click on OK to close the dialog box and confirm the changes. Use Configure to get the configuration dialog for the element. Status Bar in the Visualization If a visualization has the focus, the current X and Y position of the mouse cursor in pixels relative to the upper left corner of the image is displayed in the status bar. If the mouse pointer is located on an Element, or if the element is being processed, then the number of the element will be displayed. If you have selected an element to insert, then this element will also appear (for example, Rectangle).
2.4
CoDeSys Visualization
2-9
Placeholders At each location in the configuration dialog where variables or text are entered, a placeholder can be set in place of the respective variable or text. This makes sense if the visualization object is not to be used directly in the program, but is created to be inserted in other visualization objects as an "instance". When configuring such an Instance, the placeholders can be replaced with variable names or with text. See chapter 1 for the placeholder concept.
2.4.1
Please regard the possibility of using Placeholders as well as the special input possibilities which are useful if the visualization should be used in CoDeSys HMI resp. as Target or Web-visualization, that means if the visualization serves as the only user interface for a PLC program (see also: INTERN in category 'Input' of the configuration dialogs, Keyboard usage)
Attention: Dialogs which include the configuration of Colors and Fonts for a visualization element, can look differently depending on the currently selected target system. Possibly instead of the standard dialog there is a dialog with restricted options. This might be reasonable for projects, which are designated for a use in Target-Visualizations. See also below: Colors resp. Text.
'Extras' 'Configure' With this command, the 'Configure element' dialog opens for configuring the selected visualization element (see Select visualization element). You are given the dialog box when you double-click on the element. Select a category in the left area of the dialog box (available categories depending on element type) and fill out the requested information in the right area. This has to be done by activating options resp. by inserting the name of valid variables, whose values should define the property of the element.
Note: Note: There are also configuration dialogs available for a group of elements. Regard that the settings will be valid for the "element" group. If you want to configure the particular elements of the group, you have to resolve the group. If you have defined an element property by a "static" setting as well as dynamically by a variable, then in online mode the variable will overwrite the static value (Example: "Alarm color Inside" can be defined statically in category 'Color' and additionally dynamically in category 'Colorvariables' by a variable). If the setting is controlled by a "normal" project variable as well as by a structure variable, then the value of structure variable also will be overwritten by the "normal" project variable.
Please regard: Meter, Bar Display and Histogram must be re-grouped before !
At locations in the element configuration where variables are operative, the following Entries are possible: Variable names, for which input assistant is available Expressions which are assembled from component accesses, field accesses with constant index, variables and direct addresses. Operators and constants, which can be combined at will with the aforementioned expressions.
2-10
CoDeSys Visualization
x+y 100*PLC_PRG.a TRUE NOT PLC_PRG.b 9*sin(x + 100)+cos(y+100) Function calls are not possible. Invalid expressions result in an error message on login (Invalid Watch expression..."). Examples of invalid expressions: fun(88), a := 9, RETURN. There are two possible ways in the configuration dialogs to write global variables: .globvar" and globvar" are equivalent. The style with a dot (which is that used in the Watch- and Receipt Manager) is not allowed within an assembled expression, however. Regard also the possibility of using Placeholders (Chapter 2.4.1). Angle In the configuration dialog 'Configure Pie' in the Angle category you can each enter a value or a variable defining the start angle and the end angle of the sector element in degrees. The sector will be drawn clockwise from the start angle position to the end angle position.
Example: Enter start angle: "90", end angle: "180"
Shape In the visualization element configuration dialog box, you can select in the Shape category from among Rectangle, Rounded Rectangle, Line and Ellipse respectively Polygon, Line and Curve. The form will change into the size already set.
CoDeSys Visualization
2-11
Text In the dialog for configuring visualization elements, you can specify a text for the element in the Text category. This can be entered directly or/and a variable can be defined which will determine the text string. The usage of placeholders is possible. Also the default settings for font and alignment are done here.
Note: As soon as text parameters are additionally provided dynamically, which means by a system or structure variable (see also below, category 'Text variables' resp. 'Programmability'), the static definitions which are done in the currently opened dialog , will be overwritten ! In case of multiple definition of an element property consider the specific order of precedence concerning according to which a value might be overwritten in online mode by another (see Chapter 2.4.1).
Enter the text in the Content field. With the key combination <Ctrl>+<Enter> you can insert line breaks, with <Ctrl>+<Tab>, tab stops. Besides the input of a pure text string you can use the following formatting sequences: If you include "%s "into the text, then this location, in Online mode, will be replaced by the value of the variable from the Text Output field of the Variables category. You also can use a formatting string, which conforms with the standard C-library function 'sprintf':
Character d,i o x u c s f Argument / Output as Decimal number Unsigned octal number (without leading zero) Unsigned hexadecimal number (without leading 0x) Unsigned decimal number Single character String REAL-values [-]m.<accuracy>; plus- resp. minus-sign defines right (default) resp. left alignment; m defines minimal number of places to be displayed; accuracy defines the number of places behind the comma (default: 6).
Attention: (1) If you want to get displayed a percent sign % combined with one of the formatting strings mentioned above, you must enter "%%". For example: Enter "Rate in %%: %s" to get displayed in online mode "Rate in %: 12" (if the text display variable currently is "12"). (2) Be careful with letter case: capital letters, i.e. %S instead of %s not acceptable."
2-12
CoDeSys Visualization
The value of the variable will be displayed correspondingly in online mode. You can enter any IEC-conforming format strings, which fit to the type of the used variable.
Attention: It is not checked whether the type which is used in the formatting string matches with the type of the variable which is defined in the 'Text Output' field! Example: Input in the 'Content' field: Fill level %2.5f mm fvar1
If you enter "%t ", followed by a certain sequence of special placeholders, then this location will be replaced in Online mode by the system time. The placeholders define the display format, see the following table. Attention: Do not insert any other characters before %t in the 'Content' field (in contrast this is allowed for e.g. "%s", see above)
%a %A %b %B %c %d %H %I %j %m %M %p %S %U %w %W %x %X %y %Y %z, %Z %% Abbreviated weekday name Full weekday name Abbreviated month name Full month name Date and time representation appropriate for locale Day of month as decimal number (01 31) Hour in 24-hour format (00 23) Hour in 12-hour format (01 12) Day of year as decimal number (001 366) Month as decimal number (01 12) Minute as decimal number (00 59) Current locales A.M./P.M. indicator for 12-hour clock Second as decimal number (00 59) Week of year as decimal number, with Sunday as first day of week (00 53) Weekday as decimal number (0 6; Sunday is 0) Week of year as decimal number, with Monday as first day of week (00 53) Date representation for current locale Time representation for current locale Year without century, as decimal number (00 99) Year with century, as decimal number Time-zone name or abbreviation; no characters if time zone is unknown Percent sign
Examples: %t%a %b %d.%m.%y %H:%M:%S -> Display in online mode: Wed Aug 28.08.02 16:32:45
CoDeSys Visualization
2-13
Between the placeholders you can insert any text strings: %Today is %d.%m.%y -> Display in online mode: Today is 28.08.02 Note: If a text string is to be transferred into a translation file, which will then be used in Online mode to enable switching into another national language, it must be delimited at the beginning and end by #. Examples: "#Pump 1#" or else even "#Pump# 1" The second case might for example, in the event of multiple occurrences of the text Pump (Pump 1, Pump 2, etc.), prevent multiple appearances in the translation.
If you include" %<PREFIX>" into the text, you can enter instead of "PREFIX" a certain string, which will serve as an identifier concerning the use of dynamic texts. The prefix will be used together with an ID number, which is to be defined in the 'Variables' category of the configuration dialog in field 'Textdisplay'. The combination references to a certain text, which is defined in a xml-file available for this purpose and listing all possible dynamic texts (see chapter 3.2.2). Thus at run time the text which is indicated by the current ID-Prefix-combination will be displayed. For further information see also the description of 'Settings', category Language (chapter 2.4.2) resp. of the Language switching in a visualization (chapter 3). See there also information on the usage of UnicodeFormat. The configured text will appear online in the prescribed alignment within the element: horizontally left, center or right and vertically top, center or bottom. If you use the Font button, a dialog box for selection of the font will appear. The selection list might be restricted depending on the current target (see note in chapter 2.4.1). Select the desired font and confirm the dialog with OK. With the Standard-Font button you can set the font that is selected in the project options ('Project' 'Options' 'Editor'). If the font is changed there, then this font will be displayed in all elements except in those elements for which another font has explicitly been selected by using the Font button.
Dialog Box for Configuring Visualization Elements (Text Category)
Textvariables In category Textvariables of the dialog for configuring visualization elements you can specify a variable which should dynamically set color and font of that string which is defined in category 'Text'. At best enter the variable name with the aid of the input assistant (<F2>). You can also use components of the structure VisualObjectType to set the text properties. For this see the description of category 'Programability'; there you will find the possible values of the particular structure components and their effect.
Note: If there are corresponding static definitions in category 'Text', these will be overwritten by the dynamic parameter values.
2-14
CoDeSys Visualization
In case of multiple definition of an element property consider the specific order of precedence concerning according to which a value might be overwritten in online mode by another. The parameters of the dialog:
Parameter: Meaning: Example entry of project variable: Example Usage of variable in program: corresponding component of structure VisualObjectType: dwTextColor dwTextFlags ntFontHeight stFontName dwFontFlags
Text color Alignment (right, left, centered...) Font height in Pixel Font name
"plc_prg.var_textcolor" var_textcolor=16#FF00FF Farbe "plc_prg.textpos" ".fonth" "vis1.fontn" textpos:=2 Text right justified fonth:=16; Font height 16 pt fontn:=arial; Arial is used fontchar:=2 Text will be displayed bold
Line width In the dialog for configuring visualization elements, you can choose the line width for an element. As predefined options you find width settings from 1 to 5 pixel, additionally an other value can be entered manually (Other:), or a project variable (Variable for line width:) can be inserted. For the latter the input assistance ((<F2>) can be used.
Note: As soon as the parameter is additionally defined dynamically, i.e. by a structure variable (see below, category 'Programability'), the static setting will be overwritten in online mode.
CoDeSys Visualization
2-15
Colors In the visualization element configuration dialog box, in the Color category you can select primary colors and alarm colors for the inside area and for the frame of your element. Choosing the options no color inside and no frame color you can create transparent elements.
Note: As soon as the parameter is additionally defined dynamically by a variable, the static setting will be overwritten in online mode.
In case of multiple definition of an element property consider the specific order of precedence concerning according to which a value might be overwritten in online mode by another.
Dialog Box for Configuring Visualization Elements (Color Category)
If you now enter a Boolean variable in the Variables category in the Change Color field, then the element will be displayed in the Color set, as long as the variable is FALSE. If the variable is TRUE, then the element will be displayed in its Alarm Color.
Note: The change color function only becomes active, if the PLC is in Online Mode!
2-16
CoDeSys Visualization
If you want to change the color of the frame, then press the Frame button, instead of the Inside button. In either case, the dialog box will open for selection of the color. Here can to choose the desired hue from the primary colors and the user-defined colors. By pressing the Define Colors you can change the user-defined colors. Depending on the target the dialog might offer only a restricted selection of colors. This can be reasonable for creating projects which are intended for Target-Visualizations. In this case the colors are defined via selection lists.
Example of a target specific dialog with restricted color options
Color Variables Here you can enter project variables (e.g. PLC_PRG.color_inside), which should determine the particular property in online mode: These property definitions also or additionally can be programmed with the aid of components of the structure VisualObjectType. Therefore see the description on the "Programability" of a visualization element. There you will find a list of the possible values and their effects.
Note: The variables, entered in the Color Variables dialog, in online mode will overwrite the static values given in the 'Color' category as well as corresponding values given by a structure variable.
In case of multiple definition of an element property consider the specific order of precedence concerning according to which a value might be overwritten in online mode by another. The parameters of the dialog:
Parameter: Description: Example of an entry: Example for using the variable in the program: corresponding component of structure VisualObjectType: dwFillColor dwFillColorAlarm
"plc_prg.var_fillcol" "plc_prg.var_fillcol_a"
'Change color'
variable is TRUE frame color "plc_prg.var_framecol"
Framecolor:
dwFrameColor
CoDeSys Visualization
2-17
Framecolor alarm:
"plc_prg.var_framecol" frame color if the 'Change color' variable is TRUE The current "plc_prg.var_col_off" inside color configuration can be activated (FALSE) resp. deactivated (TRUE) Display of the frame (solid, dotted etc.) "plc_prg.var_linetype"
Fillflags:
var_col_off:=1 dwFillFlags the color definition for the fill color will not be regarded, that for the frame remains valid
Frameflags:
dwFrameFlags
Motion absolute In the visualization element configuration dialog box, in the Motion absolute category, X- or Y-Offset fields variables can be entered. These variables can shift the element in the X or the Y direction, depending on the respective variable value. A variable in the Scale field will change the size of the element linear to its current value. This value, which is used as scaling factor, will be divided by 1000 implicitely, so that it is not necessary to use REAL-variables in order to get a reduction of the element. The scaling always will refer to the balance point. A variable in the Angle field causes the element to turn on its turning point, depending on the value of the variable. (Positive Value = Mathematic Positive = Clockwise). The value is evaluated in degrees. With polygons, every point rotates; in other words, the polygon turns. With all other elements, the element rotates, in such a way, that the upper edge always remains on top. The turning point appears after a single click on the element, and is displayed as a small black circle with a white cross (
Note:
). You can drag the turning point with a pressed left mouse button.
In online mode the variables which are set in the 'Motion absolute' dialog will override the values of structure components which additionally might be used to define the same property ('Programability').
In case of multiple definition of an element property consider the specific order of precedence concerning according to which a value might be overwritten in online mode by another.
2-18
CoDeSys Visualization
Motion relative In the dialog for configuring visualization elements in the Motion Relative category, you can assign variables to the individual element edges. Depending on the values of the variables, the corresponding element edges are then moved. The easiest way to enter variables into the fields is to use the Input Assistant (<F2>). The four entries indicate the four sides of your element. The base position of the corners is always at zero. A new value in the variables, in the corresponding column, shifts the boundary in pixels around this value. Therefore, the variables that are entered ought to be INT variables.
Note: Note: Positive values shift the horizontal edges downward, or, the vertical edges, to the right! In online mode the variables which are set in the 'Motion absolute' dialog will override the values of structure components which additionally might be used to define the same property ('Programmability').
In case of multiple definition of an element property consider the specific order of precedence concerning according to which a value might be overwritten in online mode by another.
Dialog Box for Configuration of Visualization Elements (Motion Relative Category)
CoDeSys Visualization
2-19
Variables
Visualization Element Configuration Dialog Box (Variables Category)
You can enter the variables that describe the status of the visualization elements in the Variable category within the dialog box for configuring visualization elements. The simplest way to enter variables in the fields is to use the Input Assistant.
Note: In online mode the variables which are set in the 'Motion absolute' dialog will override the values of structure components which additionally might be used to define the same property ('Programability'). In case of multiple definition of an element property consider the specific order of precedence concerning according to which a value might be overwritten in online mode by another.
You can enter Boolean variables in the Invisible and Change color fields. The values in the fields determine their actions. If the variable of the Invisible field contains the value FALSE, the visualization element will be visible. If the variable contains the value TRUE, the element will be invisible. Disable input: If the variable entered here is TRUE, all settings of category 'Input' will be ignored. Change color: If the variable which is defined in this field, has the value FALSE, the visualization element will be displayed in its default color. If the variable is TRUE, the element will be displayed in its alarm color. Textdisplay: If you have inserted a "%s" in the Content field of the Text category or if you have included "%s" in the textstring, then the value of the variable which is defined in 'Textdisplay' will be displayed in online mode in the visualization object. "%s" will be replaced by the value. If you have inserted resp. included a "%<PREFIX>" in the Content field of the Text category ("PREFIX" must be a sequence of letters), then the variable resp. the numeric value which is entered here in 'Textdisplay' will be interpreted as an ID, which in combination with the prefix serves as a reference on a text, which is described in a XML-file. This text will be displayed in online mode instead of "%<PREFIX>" in the visualization object. Thus a dynamic modification of the text display is possible. See further information in the description of the dialog 'Settings', category Language (chapter 2.4.2) resp. of the Language switching in a visualization (chapter 3) If you want to edit the value of the variable in Online mode using the keyboard, you can do this via the 'Text input of variable' 'Textdisplay' in the Input category. Tooltip-display: Enter here a variable of type STRING whose value should be displayed in a tooltip for the element in online mode.
2-20
CoDeSys Visualization
Input
Dialog for configuring the visualization elements (Category Input)
Toggle variable: If this option is activated, in online mode you will toggle the value of the variables which are located in the input field by each mouse click on the visualization element. You can obtain input assistance for data entry via <F2>. The value of the Boolean variable changes with each mouse click from TRUE to FALSE and then back to TRUE again at the next mouse click, etc. Tap Variable: If this option is activated, in online mode you can switch the value of the Boolean variable which is located in the input field, between TRUE and FALSE. Place the mouse cursor on the element, press the mouse-key and hold it depressed. If option Tap FALSE is activated, the value is set to FALSE as soon as the mouse key is pressed, otherwise it is set to TRUE at this moment. The variable changes back to its initial value as soon as you release the mouse key. Zoom to Vis...: If this option is activated, you can enter in the edit field the name of a visualization object of the same project to which you want to jump by a mouse-click on the element in online mode. In this case always first the window of the target visualization will be opened before that of the current one will be closed. The following entries are allowed: The name of a visualization object of the current project (see Object Organizer) If a visualization instance that contains placeholders is to be jumped to, the placeholders can be directly replaced by variable names or text when called up. For this purpose, conform to the following syntax: <Visuname>(<Placeholder1>:=<Text1>, <Placeholder2>:=<Text2>,..., <Placeholder n>:=<Textn>). During compilation of the visualization it will be checked, whether the text matches with one of the defined replacement values defined in the placeholder list, if it does not, a warning will be output.
Example: Calling the visualization visu1, whereby the placeholders $var_ref1$ and $var_ref2$ used in visu1 are replaced by the variables PLC_PRG.var1 and PROG.var1 respectively: visu1(var_ref1:=PLC_PRG.var1, var_ref2:=PROG.var1)
If a program variable of the type STRING (e.g. PLC_PRG.xxx) has been entered instead of a visualization object, then this variable can be used to define the name of the visualization object (e.g. ,visu1') which the system should change to when a mouse click occurs (e.g. xxx:= ,visu1). If you issue the command ZOOMTOCALLER" in the Zoom to vis. field, a backward jump into the calling visualization is achieved in Online mode by a mouse click on the element, if such a constellation was configured.
CoDeSys Visualization
2-21
Note:
The implicit variable CurrentVisu (type STRING, for implicit (system) variables see 10) describes the name of the currently opened visualization object. For example it can be used in the application to control which visualization should be opened resp. to see which is the currently opened. Regard that for compiler versions < V2.3.0.7, and if the library SysLibStr.lib is not included in the project, this will only work if the names of the visualization objects are specified in captal letters (see chapter 2.1). Example: CurrentVisu:='PLC_VISU';
Execute program: If this option is activated you can enter ASSIGN- or special "INTERN"-commands in the input field, which will be executed in online mode as soon as you perform a mouse-click on the element. Press button "..." to get the dialog Configure programs where you can select the desired commands (Add) and arrange them in the desired order (Before, After). For example there is a command for language switching in a visualization. See further below chapter 'Special input possibilities for operating versions'.
Note: This feature especially is important if the visualization will be the only operating interface of a system (pure operating version).
Text input of variable 'Textdisplay': If this option is activated, in online mode you can enter text in an edit field in this visualization element. This value upon pressing <Enter> will be written to the variable that appears in the Textdisplay field of the 'Variables' category. Select in the scroll box which kind of input should be possible later in online mode. Text: An edit field will open, where you can enter the value. Numpad resp. Keypad: A window will open showing an image of the numeric resp. alphabetic keypad, where you can enter a value by activating the appropriate key elements. This might be useful if the visualization must be operatable via a touch screen. The range of valid input values can be restricted by defining a minimum and a maximum value in the edit fields Min: and Max:.
Note: In case of using Target-Visualization regard the possibility to get information on user inputs via mouse-clicks by special interface functions and to use that directly in the project. (see chapter 9)
ToolTip The dialog Text for Tooltip offers an input field for text which appears in a text field as soon as the mouse cursor is passed over the object in online mode. The text can be formatted with line breaks by using the key combination <Ctrl> + <Enter>. Security It might be useful that different user groups get different operating possibilities and display of a visualization. This can be reached by assigning different access rights concerning particular visualization elements. You can do this for the eight user groups which are available in CoDeSys (see also 'Project' 'Object' 'Properties' resp. 'Project' 'User Group Passwords'). The access rights can be assigned by activating the appropriate option in the configuration dialog 'Access rights' for a visualization element: The access rights for a visualization element and their effect in online mode: No Access Read Access Full Access
Element will not be visible Element will be visible but not operable (no inputs allowed) Element is not visible and not operable
2-22
CoDeSys Visualization
If you want to assign the access rights also to all other elements of the visualization object, activate option Apply to all visual elements.
Note: Please regard, that the access rights which are set for the visualization object in the 'Project' 'Object' 'Properties' dialog, are independent on those of the particular visualization elements !
Programability The properties of a visualization element can not only be defined by a static setting or by a "normal" project variable, but also by the components of a structure variable, which is exclusively used for programming visualization elements. For this purpose the structure VisualObjectType is available in the library SysLibVisu.lib. Its components can be used to define most of the element properties.
Note: In case of multiple definition of a element property the value of the "normal" project variables will overwrite that of the structure variable and both will overwrite a static definition.
In order to configure the element properties by using a structure variable, do the following: Open the configuration dialog, category 'Programmability' and enter a new, unique (!) variable name in the field Object Name:. For this purpose you must activate the option by a mouse-click in the checkbox. The variable automatically will be declared with type VisualObjectType, a structure which is contained in the library SysLibVisu.Lib. The declaration is done implicitly and not visible for the user. Make sure that the library is included in the library manager. After the next compile the newly assigned structure variable will be available in the project. (Hint: Activate the Intellisense functionality 'List components' in the project options, category Editor, in order to get the structure components in a selection list as soon as the variable name followed by a dot is entered). Example: If you have defined a Object Name "visu1_line" for a visualization element, then you can program the line width of this element by e.g. "visu1_line.nLIneWidth:=4".
CoDeSys Visualization
2-23
The structure VisualObjectType: The following table will show you all components of the structure and references to the corresponding items in the different categories of the configuration dialog: At the beginning of the component name the data type is integrated: n INT dw DWORD b BOOL st STRING
Component (+Data type) Effect Example (the Object Name "vis1" has been defined for the element) Shift element in Xdirection vis1.nXOffset:=val2; (element is set to position X=val2) corresponding entries in configuration dialog:
nXOffset : INT;
vis1.nScale:=plc_prg.scale_var; - Cat. Motion (element size changes linear with change absolute: Scaling of value of plc_prg.scale_var) vis1.anglevar:=15; (element rotates clockwise by 15 ) vis1.visible:=TRUE; (element is invisible) - Cat. Motion absolute: angle - Cat. Color: No color inside + No frame color - Cat.Colorvariables: Fillcolor + Framecolor - Cat. Text: entry at Content'
stTextDisplay : STRING;
bToggleColor : BOOL; color change when toggling between TRUE and FALSE
vis1.bToggleColor:=alarm_var; - Cat. Input: Toggle (As soon as alarm_var gets TRUE, the variable + element gets the color defined via the - Cat. Variables: components dwFillColorAlarm, change color dwFrameColorAlarm resp. via the settings
2-24
CoDeSys Visualization
Effect
Example (the Object Name "vis1" has been defined for the element)
in category 'Colorvariables' or 'Color'. bInputDisabled: BOOL; stTooltipDisplay: STRING; dwTextFlags: DWORD; if FALSE: Inputs in category 'Input' are ignored Text of the tooltip vis1.bInputDisabled:=FALSE; (no input is possible for this elementt) vis1.stTooltipDisplay:='Switch for .....'; - Cat. Variables: Disable Input' - Cat. Text for Tooltip: 'Entry in Content:' - Cat. Text: Horizontal and Vertical options - Cat. Textvariables: Textflags
vis1.dwTextFlags:=24; Text position: (Text will be placed in the center of the 1 left justified element (4 + 20) 2 right justified: 4 centered horizont. 8 top 10 bottom 20 centered vertically Note: Always set a horizontal and a vertical position (addition of values)! Text color (definition of colors see subsequent to this table) vis1.dwTextColor := 16#00FF0000; (Text is blue-colored)
dwTextColor : DWORD;
- Cat. Text: Font | Color - Cat. Textvariables: Textcolor - Cat. Text: Font | Grad' - Cat. Textvariables: Font heigth - Cat. Text: Schrift | Schriftschnitt - Cat. Textvariables: Fontflags
nFontHeight : INT;
vis1.nFontHeight:=16; Font height in Pixel. should be in range 10- (Text height is 16 pt) 96 Font display. Available vis1.dwFontFlags:=10; (Text is displayed blue and cancelled) flags: 1 italic 2 bold 4 underlined 8 cancelled + combinations by adding values vis1.stFontName:=Arial; (Arial is used)
dwFontFlags : DWORD;
- Cat. Text: Schrift | Schriftart - Cat. Textvariables: Fontname - Cat. Line width
nLineWidth : INT;
dwFillColor : DWORD; Fill color (definition of vis1.dwFillColor":=16#00FF0000; - Cat. Color: Color | colors see subsequent (Element ist im "Normalzustand" blau) Inside to this table) - Cat. Colorvariables: Inside dwFillColorAlarm : DWORD; Fill color as soon as bToggleColor gets TRUE, see above) (definition of colors see subsequent to this table) vis1.dwFillColorAlarm:=16#00808 - Cat. Color: Alarm 080; color | Inside (as soon as Variable togglevar gets - Cat. Colorvariables: TRUE, the element will be displayed greyInside Alarm colored) - Cat. Color: Color | Frame - Cat. Colorvariables: Frame
dwFrameColor: DWORD;
Frame color vis1.dwFrameColor:=16#00FF0000; (Frame is blue-colored) (definition of colors see subsequent to this table)
CoDeSys Visualization
2-25
Effect
Example (the Object Name "vis1" has been defined for the element)
dwFrameColorAlarm: DWORD;
Fill color as soon as bFrameColor gets TRUE, see above (definition of colors see subsequent to this table) Color, as defined by the color variables, can be displayed or ignored 0 = show color >0 = ignore setting Display of frame: 0 full 1 dashed ( --- ) 2 dotted ( ) 3 dash-point ( _._._ ) 4 dash-point-point (_.._.. ) 8 blind out line
vis1.dwFrameColorAlarm:=16#0080 - Cat. Color: Alarm color | Frame 8080; (as soon as Variable vis1.bToggleColor gets TRUE, the frame - Cat. Colorvariables: Frame Alarm will be displayed grey-colored)
dwFillFlags: DWORD;
- Cat. Color: No color inside + No frame color - Cat. Colorvariables: Fillflags - Cat. Colorvariables: Frameflags
dwFrameFlags: DWORD;
Defining color values: Example: e1.dwFillColor := 16#00FF00FF; A color is entered as a hex number which is composed of the Blue/Green/Red (RGB) components. The first two zeros after "16#" should be set to in each case, to fill the DWORD size. For each color value 256 (0-255) colors are available. FF Blue component 00 Green component FF Red component
Example for a blinking visualization element:
Define a global variable 'blink1' of type VisualObjectType in the configuration of a rectangle. In a program of function block the value of a component of the structure can be modified. PROGRAM PLC_PRG VAR n:INT:=0; bMod:BOOL:=TRUE; END_VAR (* Blinking element *) n:=n+1; bMod:= (n MOD 20) > 10; IF bMod THEN blinker.nFillColor := 16#00808080; ELSE blinker.nFillColor := 16#00FF0000; END_IF
(* Grau *) (* Blau *)
2-26
CoDeSys Visualization
Table As soon as a table is inserted for the purpose of visualization of an array, the dialog Configure Table will be opened. Besides the categories 'Tooltip' and 'Security' which are also available for other visualization elements, the following categories will be available for configuring display and contents of the table: Regard that the options in the color and font selection dialogs might deviate from the default depending on the current target (see note in chapter 2.4.1). Category Table:
Dialog for the configuration of a Table, Category Table
Do the following table settings: Data array: Insert the name of an array which should be visualized in the table. It is recommended to use the input assistant (<F2>) resp. the Intellisense function. Slider size: Insert here the desired height of the slider which will appear at the bottom of the table element if the display of the array columns exceeds the element width. Column header, Line header: Activate these options if you want to get displayed the titles in the table. The line title reflects the array index (first column of the table), the column title can be defined in category 'Columns'. Category Columns: Here you define the table elements. In the left window you get al list of all elements, which are handled in the array per index. In case of an array of a structure these would be the structure components.
Dialog for the configuration of a Table, Category Columns
CoDeSys Visualization
2-27
Using the arrow button > you can transfer a selected component from the left window to the right window where you define the set of elements to be displayed in the table. Pressing button >> all elements will be transferred at a single blow. In the same manner you can remove elements from an already defined set (<, <<). In order to modify the default settings concerning the display of the table column for one of the elements, perform a double-click on the desired entry in the right part of the window, or press button '...' to open the dialog 'Configure columns':
Dialog for Configuring a Table, Category Columns, Column Properties
Editing the column header and the column width: Initially the edit field Column header will contain an automatically created title (e.g. "PLC_PRG.arr1[INDEX].iNo" in case of an array of structure. for the column representing the structure component "iNo"). which you can change Further on the Column width (number of characters) can be set. Editing configuration parameters for all elements of a column: By default the table fields are displayed as simple rectangles and the entries are not editable. If you however activate button Edit template for the currently marked column, you can modify the parameters of the fields of this column, e.g. the line width, text input etc. The template affects all fields of the current column and can be edited via the known configuration dialog for a visualization element. If you want to configure only one or several particular fields of the column, you can use the following placeholders determining the desired row and column: $ROWCONST$, $COLCONST$, INDEX. (INDEX has the same effect as $ROWCONST$).
Examples for the use of placeholders in column-templates: Example 1: You want to visualize an array "arr1 [0..2] of BOOL" (table with 1 column) and you want, that in online mode by a mouse-click on a table cell the cell gets red-colored and the corresponding array element will be toggled and vice versa. To reach this activate 'Use template' in the configuration dialog for the column and define the template as follows: Category 'Input', Action 'Toggle variable': "PLC_PRG.arr1[INDEX]. Category 'Colors': Alarm color red. Category 'Variables', Action 'Change color': "PLC_PRG.arr1[INDEX]. Example 2: The following template configuration has been created for a table column representing Index 0 of an array:
2-28
CoDeSys Visualization
the field in line 6 (line number, index) is invisible in the field in line 7 no edit field can be opened in all fields of column 0 the color will change to alarm color. The other fields of the column remain in base color. Always entered automatically, but of course changeable is the textdisplay configuration, which combined with the %s entry in category Text effects that the corresponding variable value will be displayed in the table field. Placeholder entries in the configuration fields can be connected with AND resp. OR; Example: "$ROWCONST$=1 OR $ROWCONST$=3" makes that both fields will get the respective setting. The use of the currently configured template can be activated or deactivated: Option Use template. Category Rows:
Dialog for configuring a Table, Category Rows
CoDeSys Visualization
2-29
Category Selection:
Dialog for configuring a Table, Category Selection
Here you can set the following parameters concerning the selection behaviour within the table: Selection color: Press this button to define a color for selected cells. You get the standard dialog for choosing a color or a target-specific color selection list (see note in chapter 2.4.1). Selection type: Define which part of the table will be selected when you perform a mouse-click on one of the table fields in online mode:
Select single cells: Only the cell will be selected. Select only rows: The whole line will be selected. Select only columns: The whole column will be selected. Select rows and columns: The whole column and line will be selected.
Frame around selected cells: A selected cell gets surrounded by a frame. Variable for selection X, Variable for selection Y: Here you each can enter a project variable, which will indicate the X- resp. Y-Index of the selected table cell.
Example: Create a table element visualizing the array of a structure:
Define the following structure: TYPE strucTab : STRUCT iNo: INT; bDigi : BOOL; sText:STRING; byDummy: BYTE; END_STRUCT END_TYPE In PLC_PRG define the following array: arr1:ARRAY [1..5] OF strucTab; and the following variables: selX:INT; selY:INT; Create a visualization object and insert a table element. Configure like follows:: Cat. Table: data array: "PLC_PRG.arr1"
2-30
CoDeSys Visualization
Cat. Columns: (Close the dialog which will open with YES) Transfer the components iNo, bDigi, sText to the right window In the right window perform a double-click on the first entry (PLC_PRG.arr1[INDEX].iNo) and in the dialog which will open, replace the default title by "Number". Confirm with OK and also define new column titles for the other two entries (e.g. "Value" and "Text"). In category 'Spec.Table' enter at 'Variable Selection X': "PLC_PRG.selX" and at Variable Selection "Y: PLC_PRG.selY". Activate option 'Frame around selected cells'. Press button 'Selection color' and choose color 'yellow'. Close the configuration dialog with OK. The table element now should be displayed as shown in the following:
At the left border the numbers of the array index, at the top the titles of the selected structure components. You can modify the column widths by placing the cursor on the separator between two columns and moving the mouse as soon as the cursor appears as a horizontal double-arrow. . In online mode the current values of the array elements will be displayed in the table cells. As soon as you select a table cell by a mouse-click, it will get yellow-colored and surrounded by a frame. Example:
ActiveX-Element The ActiveX-Element serves for displaying a passive ActiveX Control within a visualization. The element is usable on Windows32 based systems in CoDeSys HMI and in the CoDeSys TargetVisualization. The configuration dialog is opened by a double-click on the inserted element and offers three subdialogs, for selecting the control type, for defining method calls and for the configuration of the display: Category Control:
Dialog Configure ActiveX-Element, Category Control
CoDeSys Visualization
2-31
In this dialog you can mark the desired ActiveX Control in the selection list offering all ActiveX Controls which are registered on your computer. Category Methodcalls: Here you configure the method calls for the chosen ActiveX Control:
Dialog Configure ActiveX-Element, Category Methodcalls
Webbrowser: These input fields only can be edited if you are configuring a control element which supports the IWebBrowser interface (e.g. Internet Explorer or Mozilla Browser). In this case CoDeSys can directly call the method Navigate (other method calls must be controlled via a user defined Dll, see below 'Additional Call'). Enter an URL as a parameter value in field Variable for URL(Input as a string between inverted commas) resp. a project variable of type STRING defining an URL. The browser will be called as soon as the variable entered in field Condition for call gets TRUE (rising edge). If no call condition is defined here, in the Target-Visualization the browser will be called in each cycle of the visualization task! Additional Call: Via a user defined Windows-Dll you can define method calls for the ActiveX Control in order to control the behaviour of the control at a call. For this purpose you must enter the path of the Dll in the field at Dll for Call. If you press the button you get the dialog for opening a file where you can browse for a Dll. If the file is in the visualization files directory as defined in the project options, only the file name will be entered, otherwise the complete file path.
Attention: If the Dll is to be used on a runtime system with a Target-Visualization, it must explicitly be copied there. When the Control is called in the Target-Visualization, only the filename contained in the path will be regarded.
The Dll is called as soon as the variable defined below in Condition for call gets TRUE (rising edge). If no condition is specified, in the Target-Visualization it will be called in each cycle of the visualization task! Regard the following when creating an appropriate Dll: The Dll must export a method "ExecuteActiveXCall" with this function prototype:
void ExecuteActiveXCall(IUnknown* pUnk, char* pszId, char* pszParam, char* pszReturnBuffer, int nReturnBufferSize, DWORD* pdwReturnFlag);
2-32
CoDeSys Visualization
The function will be called with the following parameters which can be defined in the configuration dialog:
pszId: pszParam:
string resp. string variable specified in field Methodidentification value specified in field Parameter
The parameter pUnk allows a query of further Com(ActiveX-)interfaces. With these interfaces you can call any Method on your ActiveX-Control with any parameters packed in a string! The parameters pszReturnBuffer, nReturnBufferSize and pdwReturnFlag currently are not used. For an example of a Dll source file see Appendix B. Category Display: In this dialog you can specify the variables defining the position (X-Offset, Y-Offset, see description of configuration category 'Motion absolute')and visibility of the control element (Invisible, see description for configuration category 'Variables'.
Dialog Configure ActiveX-Element, Category Display
Scrollbar The scrollbar element can be used to modify the value of a variable (or vice versa). The slider position will correspond to the value of an assigned variable within a defined value range.
Scrollbars, Example
The user can move the slider in online mode by clicking on the slider and then moving it by moving the mouse - or alternatively by clicking on one of the arrow symbols on the scrollbar, whereby each mouse-click will move the slider (and thus the variable value) by 1 in the
CoDeSys Visualization
2-33
respective direction: If the slider is moved to the right resp. up, the value will be increased, if the slider is moved to the left resp. down, the value will be decreased. A vertical or horizontal display of the scrollbar can be reached by a respective shaping of the element (see 'Insert' 'Scrollbar'). The configuration dialog gets opened by a double-click on the element.
Configuration dialog for Scrollbar
Slider: Enter here the path of the project variable, the value of which should correspond to the slider position between the given Minimum value and Maximum value (e.g. "PLC_PRG.ivar"). So, when the slider gets moved in online mode, the value of the variable will change. Vice versa, if the variable gets modified by any other input the slider would get moved correspondingly. Minimum value, Maximum value: Boundaries for the value range which can be displayed for the variable assigned to the slider. In horizontal scrollbars the minimum value corresponds to the left-most position of the slider, in vertically scrollbars to the bottom-most position. The values can be entered directly or via a project variable (e.g. "0", "200", "PLC_PRG.minvar"). Invisible: The visibility of the element in online mode can be controlled dynamically, if here an appropriate boolean variable is entered, e.g. "PLC_PRG.bScrollbar_vis". A static definition is also possible ("TRUE", "FALSE" resp. "0", "1"). Default: visible. Tooltip-display: If "dynamic texts" should be used for the tooltip text, here the ID of the prefixID-combination must be entered, which uniquely references the desired text in a specific language file (xml-format). You can enter the ID directly (string, e.g. "tt_scrollbar1") or via a project variable of string format which gives the ID (e.g. "PLC_PRG.tt_ID"). Concerning this see the help pages on Tooltip and generally on Language Switching. Meter The dialog for configuring a Meter element will open automatically as soon as you insert the element into a visualization object. A Preview is part of the dialog, immediately showing how the element will look as a result of the currently set parameters: Arrowtype: Define the type of the arrow which will point at the current value on the Meter. Possible types: Normal arrow, Thin arrow, Wide arrow, Thin needle.
2-34
CoDeSys Visualization
Arrow start, Arrow end: Here you define the start and the end positions of the scale on a virtual circular arc in Degrees (angle). (Example: a Start angle of 180 and an End angle of 0 will define a upturned semicircle). Arrow color: This button opens the standard dialog for choosing a color or a target-specific color selection list (see note in chapter 2.4.1). Define the color of the pointer.
Dialog for the configuration of a Meter element
Variable/Scale: This button opens the dialog Configure scale and variable:
Dialog for Configuring the Scale and Variable for a Meter element
Scale start, Scale end: lowest and highest value on the scale, e.g. "-4" and "4". Main scale: Define which intervals on the scale should be marked "with all", that means which should get a scale pitch and a label. If you insert e.g. "2", each second integer value will be indicated. Sub scale: In addition to the main scale (Label + long pitch lines) here you can define a sub-scale which will be displayed as short pitch lines without any labels. Unit: Define here the scale unit, e.g. "cm" or "sec". The unit is indicated by a label at the origin of the pointer.
CoDeSys Visualization
2-35
Scale format (C-Syntax): According to the C-syntax you can define the display format of the scale labels; see the description concerning Category 'Text'. Example: If you insert "%1.1f" the scale values will be indicated by a floating point number with one decimal place before and one after the comma (e.g. "12.0") Variable: Here you can define a variable which is assigned to the pointer position. (e.g. "PLC_PRG.posvar") Font selection: This button will open the standard dialog for defining the font used in the Meter element. Color areas: This button opens the dialog Configure color areas: Here you can define a separate color for each partition of the scale. Begin of area, End of area: Insert here the start and end values of the scale partition which should get the color defined in the following: Color selection: This button opens the standard dialog for choosing a color or a target-specific color selection list (see note in chapter 2.4.1). Confirm your selection with OK, which will close the dialog, and press button Add, whereupon the color and the assigned partition of the scale will be added to the window 'Active areas'. In order to remove an already defined area, select the entry and press Delete. If the option Durable color areas is activated, the defined color ranges will be displayed permanently, otherwise in online mode just that partition of the scale will be colored which contains the current value of the respective value. Label: Depending on which of the options is activated (inside or outside), the scale labels are placed at the inside or the outside of the circular arc of the scale.
Dialog for the configuration of color areas for a Meter
Additional settings: Frame inside, Frame outside: If one or both of these options is/are activated, an inner or outer frame will be added to the scale arc. Additional arrow: In addition to the main pointer a little arrow will indicate the current value directly on the scale. No Scaling: If this option is activated, the inserted element cannot get resized.
2-36
CoDeSys Visualization
Bar Display
Dialog for the configuration of a Bar Display element
This dialog will be opened as soon as you insert a Bar Display element into a visualization object. A Preview is part of the dialog, immediately showing how the element will look as a result of the currently set parameters: Diagram type: Choose one of the options: 'Scale beside bar', 'Scale inside bar' und 'Bar inside scale'. Orientation: Define one of the options: Horizontal or Vertical bar. Running direction: Choose whether the bar should be elongated corresponding to a growing value of the assigned variable in Left Right or in Right Left direction. Bar color: This button opens the standard dialog for choosing a color or a target-specific color selection list (see note in chapter 2.4.1). Define a color for the bar in normal state (no alarm). If option 'Use color areas' (see below) is activated, no entries are possible. Alarm color: This button opens the dialog Configure alarm, where you define at which value the bar will be displayed in alarm color and which is the alarm color: Insert the desired limit value in the edit field and activate one of the Conditions greater than or lower than, in order to define whether values higher or lower than the limit value should set off an alarm. Press button Alarm color to open the standard dialog or a target-specific color selection list (see note in chapter 2.4.1) for choosing the alarm color. Close both dialogs with OK in order to confirm the settings and to return to the main dialog for configuring the bar display. If the option 'Use color ranges' (see below) is activated, no entries are possible. Variable/Scale: This button opens the dialog Configure scale and variable, which corresponds to that used for the Meter element. Element frame: If this option is activated a frame will enclose the bar display. Bar background: If this option is activated, the whole display range will be indicated by a black bar in the background of the current values' bar, otherwise only the current values' bar will be displayed. Use color areas: If this option is activated, any settings defined in the dialogs for 'Bar color' and 'Alarm color' (see above) will not be valid. In this case the color area definitions will be used, which have been made in the dialog 'Configure color areas'. This dialog can be opened by pressing button 'Color areas' (see below). No Scaling: If this option is activated, the inserted element cannot get resized. Color areas: This button opens the dialog Configure color areas where you can define a separate color for each partition of the scale. These definitions will only be valid if the option 'Use color areas' (see above) is activated. Use the dialog as described for the Meter element.
CoDeSys Visualization
2-37
Histogram A histogram element can be used to visualize an array. The values of the array elements will be represented by bars or lines side by side, indicating the current values of the element by their height. The configuration dialog will be opened as soon as you insert a histogram element into a visualization object. A Preview is part of the dialog, immediately showing how the element will look as a result of the currently set parameters: Presentation: Activate one of the options Barchart or Lines. Show horizontal lines: If this option is activated, horizontal lines spanning the diagram will additionally display the scale gradation. No Scaling: If this option is activated, the inserted element cannot get resized. Alarm color: This button opens the dialog Configure alarm, where you define at which value the bar will be displayed in alarm color and which is the alarm color: Insert the desired threshold value in the edit field and activate one of the Conditions greater than or less than, in order to define whether values higher or lower than the limit value should set off an alarm. Press button Alarm color to open the standard or a target-specific (see note in chapter 2.4.1) for choosing the alarm color. Close both dialogs with OK in order to confirm the settings and to return to the main dialog for configuring the histogram.
Dialog for the configuration of a Histogram
Variable/Scale: This button opens the dialog Configure scale and variable, which can be filled like described for the Meter element. Color areas: This button opens the dialog Configure color areas: Here you can define a separate color for each partition of the scale. See the description of the Meter where the same dialog is available. Bar color: This button opens the standard or a target-specific dialog (see note in chapter 2.4.1) for choosing a color. Define a color for the bar in normal state (no alarm). Define which range of the array should be displayed: Arraybegin: First array element to be displayed (Index). Arrayend: Last array element to be displayed (Index). Barwidth: Define the width of the bars in percent by the total width available for one bar.
2-38
CoDeSys Visualization
Example: See in the following picture an example of the online display (bars resp. lines) of a histogram which represents an array arr1 [0..4] of INT. The number of bars appropriately was set to "5", the scale start to "4", the scale end to "24", the main gradation was set to "2", the sub-gradation to "1" and the scale range 0 8 has got assigned another color (dark grey) than the rest of the scale range. Further on the bars should be displayed alarm-colored (blue) as soon as the value of the corresponding array element exceeds "8". You see the array elements arr1[2] and arr1[3] currently being in alarm state:
Alarm table The element 'Alarm table' is used to visualize alarms, which must be defined before in the CoDeSys Alarm configuration. As soon as the element gets inserted in the visualization object, the dialog 'Configure alarm table'. Besides the known categories for configuration of tooltip and security the settings described in the following concerning display and selection in the table can be made. Regard that the options in the color and font selection dialogs might deviate from the default depending on the current target (see note in chapter 2.4.1). Category Alarm table:
Dialog for configuration of a alarm table, category Alarm table
CoDeSys Visualization
2-39
Change alarm group: Press this button to get the selection tree of the alarm configuration, which offers all alarm groups currently defined. Choose the desired group (which even may contain just one alarm).
Note: The name of the alarm group, as it is displayed here (e.g. "System/Alarmgroup1") can be used as PREFIX in a XML-file for dynamic texts in order to get dynamic language switching for the message texts in the alarm table; the associated ID in this must be the number of that line in the Alarm group configuration table, that defines the respective message text.
Priority: Define the priority for which you want to get displayed all alarms. Permissible range: 0 to 255. Alarm classes: Mark a class which you want to get displayed and press button Add to add the class to the list in the window 'Alarm classes'. Do this for all required classes. In order to remove a marked entry from the alarm classes window press button Delete. Activate options Column heading resp. Row heading, if the headings should be displayed in the alarm table. Category Settings for sorting: Define here according to which criteria the alarm table should be sorted: Sort column: Sorting according to Priority, Alarm class, Date/Time or Alarm state Sort order: Ascending or Descending; Example: Ascending according to priority means that the table will start with alarms of priority 0 (if available), followed by higher numbered priorities.
Note: When using in a Target-Visualization this settings are not regarded in the display of the alarm history. There the sorting always is descending according to the date.
Category Columns: Define here, which of the columns (alarm parameters) should be displayed in the alarm table: The parameters are defined -- except for date and time (alarm is coming) and alarm state (see CoDeSys User Manual, Alarm Configuration) in the Configuration of the alarm groups: Bitmap, Date, Time, Expression, Value, Message, Priority, Type, Class, State, Target value (for alarm types DEV+ and DEV-), Deadband.
2-40
CoDeSys Visualization
Using the buttons ">", ">>", you can take single resp. all parameters from the left to the right window. The selection defined in the right window will be displayed in the alarm table. Using the buttons "<" resp. "<<" entries can be removed from the selection. For each column you can open the dialog 'Configure columns' by a double-click on the entry in the right window. In this dialog Column header and Column width can be defined. Category Selection settings for alarm table: Define here some settings for the display for the chosen table fields: Selection color: This button opens the standard dialog for choosing a color. Define the color in which selected fields should be displayed. Row height: Height of the table rows in Pixel. Slider size: Height of the slider (Pixel) at the bottom of the table. Frame around selected rows: If this option is activated, selected table rows will get a frame. Show statusline: If this option is activated, below the alarm table a status bar will be displayed providing the following buttons for the operation in online mode: Acknowledge: All alarm entries marked in the alarm table get acknowledged. Acknowledge all: All alarm entries listed in the alarm table get acknowledged. History: If this button is pressed, instead of the current status of the alarms the table will show a complete list of all events which have occurred up to now (all transitions between any alarm stati). In this list no acknowledgement is possible! Any new events will be added currently. If you have defined a record file, also there you will find this history for all alarm classes, for which the action 'Save' has been activated. Start: cancels Stop (see below) Stop: The current update of the list with newly occurring events will be stopped until it is restarted by pressing button 'Start'.
CoDeSys Visualization
2-41
Acknowledge variables: This option is only available as long as you have not chosen option 'Show statusline' (see above). If it is activated, the functions described above for the status string buttons can get controlled by variables. In order to define these variables, choose a function from the selection list and enter a project variable in the assigned edit field. Thus for example the acknowledgement of all alarms in online mode can be done by a rising edge of the assigned variable.
Note: The Web-Visualization might be configured in a way, that in online mode a tooltip will display the full string of a text entry, which is only partially visible in the alarm table.
Trend The Trend element can be used to log the time dependent behaviour of variable values in the online mode. It can be compared with the trace functionality. The online presentation is done in a diagram, in case of logging to a text file each of the values is written to a separate line. In the dialog for configuring visualization elements in category 'Trend' you can do the following settings:
Dialog for configuration of a Trend element
2-42
CoDeSys Visualization
Curve: X/t, horizontal axis = time axis, vertical axis = scale of values Orientation: Left-right or Right.-left: The latest value will be displayed on the left/right side; Axis: Horizontal Axis:
Dialog for configuration of the horizontal axis in the trend element
Division lines: Activate option 'visible', if vertical division lines should be displayed which are elongating the scale marks. In this case define the 'Scale': The given number defines the interval between the division lines on the horizontal axis. Type (normal ___, dashed _ _ _, dotted ....., dashdotted _ . _ .) and color of the lines can be defined in dialogs which will open when you perform a mouse-click on the corresponding rectangle showing the currently set line type resp. color. Scale: The shown range of the scale is determined by the entry for Duration. If here e.g. " T#20s0ms" is defined, the scale will display a period of 20 seconds. The Main division and the Sub scale division, which will be displayed by the means of long and short marks are to be defined according to the same syntax. Degree of accuracy: Define here (in the standard format for dates, e.g. T#5ms) the interval for displaying the current values of the variables. Legend: Here you define the display of the legend. Via button Font the standard dialog for setting the font will be opened. At Scaling define the distances between the particular letterings on the scale (e.g. T#4ms, if the scale markings should get a lettering each 4 milliseconds. The lettering will contain the time and/or date, depending on which options are activated. The desired format each can be defined in the field 'format'. Variables: Here you can define project variables, which contain the zoom values resp. offset values for the horizontal scale. For example the offset of the display range of the horizontal axis will be set to "10" as soon as the variable assigned here gets value 10. Symbol bar: If option use is activated, at the bottom of the element a horizontal symbol bar will be added, providing buttons for scrolling and zooming in online mode. The simple arrow buttons will move the displayed range along the time axis step by step, the double arrow buttons will shift it to the end resp. start of the record. The zoom buttons allow a zooming of the horizontal
CoDeSys Visualization
2-43
scale step by step. To get a possibility to restore the original settings concerning zoom and offset, define the vertical symbol bar to get the 'home' symbol. Vertical axis:
Dialog for configuration of the vertical axis in the trend element
Division lines: corresponding to the horizontal axis (see above) Scale: Define whether the scale should be displayed at the left or right border of the trend diagram. Choose the Start value (lower end) and End value (upper end) of the scale as well as the Main and Sub scale divisions (longer and shorter markings will be displayed in the here defined distances). Legend: Font and divisions; see above, horizontal axis Variables: see above, horizontal axis Symbol bar: see above, horizontal axis, additionally there is a standard settings concerning zooming and offset of the axes. "home" button for restoring the
Recording: Define here whether the trend should be recorded 'only online', i.e. the time dependent behaviour of the variable values will be displayed using the chosen range of the scale, or whether the record should be saved to history file, which can be configured after pressing the button 'History'. The dialog corresponds to that which is used for the configuration of the alarm log file. Regard: If the target-specific option 'Store trend data in the PLC' is activated (see Target Settings, category Visualization), the path defined here will be ignored and the log file will be stored in the download directory of the PLC. In the log file for each time of measurement a separate line is written which contains the name and the values of all regarded variables. Each line starts with a unique identifier in DWORD format, which is built from the date of measuring. Choose variable: Press this button to get the dialog Variables, where you can configure the variables for which the trend record should be done and how they should be displayed.
2-44
CoDeSys Visualization
Enter a project variable in column Variable (mouse-click on the field will open an edit frame). It is recommended to use the input assistant <F2> or Intellisense function. Color and Line type for the display of the variable in the record you can define by a mouseclick on the corresponding field in column Color (standard dialog for choosing a color resp. by selecting a line type in the corresponding field of column Line type (normal ___, dashed _ _ _, dotted ....., dashdotted _ . _ .).
Dialog for configuration of the variables in the trend element
In column Marker you can define a variable, which will provide the currently recorded value when you use the marker function in online mode. The marker will be displayed as a little grey triangle in the upper left corner of the diagram. If you click on the triangle and keep the mouse-button pressed, you can shift a vertical marker line along the horizontal time axis. The variable defined as 'marker' then will read the corresponding value from the record curve of the associated project variable. Do the settings for all variables you want to record. Via button Add a further line will be added at the end of the list. A line can be deleted by button Delete. Curve configuration: This button opens the dialog Curve configuration. Here some settings concerning the trend curves can be done:
Dialog for doing the curve configuration for the trend element
CoDeSys Visualization
2-45
Curve type: Select one of the options Straight line, Steps or Points. For the first two types the display of Additional points can be defined. For displaying a point a bitmap can be defined, otherwise a filled rectangle (same color as curve) will be used as point symbol. Press the rectangle next to Bitmap to get the standard dialog for selecting a bitmap file. Via Delete the currently set bitmap can be removed from the configuration. Tolerance band: You can define an upper and lower limit value on the vertical axis to be displayed as a tolerance band. For each band a color (Press the color rectangle to get the selection dialog) can be defined. If the bands should be displayed in online mode, activate option Tolerance band as line. If you want the curve to get displayed in the color defined for the respective band as soon as exceeding the tolerance value, activate Curve color outside tolerance like tolerance band. Activate Both or None if you want to activate both or none of the above described display options at a time. Example: Display of a trend element in online mode: 1. Declaration in program PLC_PRG: VAR in: INT; rSinus:REAL; rValue:REAL; rSlider1:REAL; (*for marker function*) rSlider2:REAL; (*fr marker function*) END_VAR 2, Program part of PLC_PRG: n:=n+1; rValue := rValue + 0.01; rSinus:=SIN(rValue)*50 + 50; IF n>100 THEN n:=0; END_IF 3. Configuration of a trend element in a visualization: Orientation Left-Right, History activated Horizontal axis: Division lines: T#2s, Duration: T#10s, Main: T#1s, Sub scale: T#500ms, Degree if accuracy: T#200ms, Legend: Time Format ('hh':'mm':'ss'), Scaling T#2s. Symbol bar activated. Vertical axis: Division lines visible, Scale: 10, dotted, grey; Scale left, Start: 0, End: 100, Main: 10, Sub scale: 5; Legend: 10; Symbol bar activated. Variables: 1. Variable PLC_PRG.rsinus, blue line, Marker: PLC_PRG_TRD.rSlider1; 2. Variable PLC_PRG.n, red line, Marker: PLC_PRG_TRD.rSlider2 Curve configuration: Straight line, no tolerance band Configuration of two display fields for the current record values provided by the marker variables: Rectangle element 1: Category Text: insert "%s" in the Content field; Category Variables: insert in field Textdisplay: PLC_PRG.rSlider1 Rectangle element 2: Category Text: insert "%s" in the Content field; Category Variables: insert in field Textdisplay: PLC_PRG.rSlider2 (Additionally insert a rectangle element at the left border of the rectangle elements 1 and 2, showing the curve color of the corresponding record variable)
2-46
CoDeSys Visualization
The record is running from the left to the right; the latest value is shown on the leftmost position; every 200 milliseconds the current value will be added to the display. The arrow buttons in the symbol bars allow shifting the displayed time range. Using the simple arrow buttons you can shift step by step, using the double arrows you get to the end resp. start of the record. For example: if you go to the start of the record by pressing the double arrows pointing to the left, you get a still display of the former values. If you then move the marker (grey tr upper left corner) along the time axis, you can read the exact values of each of the both recorded variables for each time in the rectangle elements below the diagram. Bitmap You can do the following settings in category 'Bitmap' in the visualization element configuration dialog box: Specify, which image file should be used. This specification can be static or dynamic. If there are entries both in the 'Bitmap' field and in the 'Bitmap Variable' field, then that in the 'Bitmap' field will be ignored: Bitmap: Static definition: You can enter the path of an image file available in the local file system. Via button ... the standard dialog for browsing for a file will be opened, where you can select the desired file. Bitmap variable: Dynamic definition: A project variable of type STRING can be entered here, containing the name of the image file currently to be used. This allows dynamic change of images in online mode, but only works with image files which are entered in the project-global "bitmap list" (see chapter 'Extras' 'Bitmap list'). The string-variable always only must get assigned the file name, even if there is a full path specified in the bitmap list. See in the following example 'stBitmap' as string-variable, which is got assigned various image files that are part of the global bitmap list. CASE nId OF 0: stBitmap := 'background.bmp'; 1: stBitmap := 'deutest.bmp'; 2: stBitmap := 'alarm.bmp'; END_CASE If stBitmap e.g. is declared in object PLC_PRG, it can be entered here in the configuration dialog in field 'Bitmap variable' like follows: PLC_PRG.stBitmap.
CoDeSys Visualization
2-47
Enter the bitmap file and its path in the Bitmap field. You can use the ... button to open the standard Windows Browse dialog box from which you can select the desired bitmap. The following entries affect the frame of the bitmap. By selecting Anisotropic, Isotropic or Fixed you specify how the bitmap should react to changes in the size of the frame. Anisotropic means that the bitmap remains the same size as the frame which allows you to change the height and width of the bitmap independently. Isotropic means that the bitmap retains the same proportions even if the overall size is changed (i.e., the relationship between height and width is maintained). If Fixed is selected, the original size of the bitmap will be maintained regardless of the size of the frame. If the Clip option is selected together with the Fixed setting, only that portion of the bitmap that is contained within the frame will be displayed. If you select the Draw option, the frame will be displayed in the color selected in the Color and Alarm color buttons in the color (default- or target-specific) dialog boxes. The alarm color will only be used if the variable in the Change Color field in the Variable category is TRUE. In the selection list in the lower part of the dialog you can define whether the bitmap should be inserted in the project (Embed) or whether just a link to an external bitmap-file (path as entered above in the 'Bitmap' field) should be created (Remember the Link). It is reasonable to keep the bitmap file in the project directory, because then you can enter a relative path. Otherwise you would enter an absolute path and this might cause problems in case you want to transfer the project to another working environment. Visualization When you insert a visualization as an element in another visualization, you are creating an "instance" (reference) of the visualization. The configuration of this instance can be done in the Visualization category within the visualization element configuration dialog box. Enter the object name for the visualization, which should be inserted, in the Visualization field. Use the ... button to open a dialog box containing the visualizations available in this project. Any visualization may be used with the exception of the current one. The possible settings concerning the visualization frame are the same as described for a bitmap (see above).
2-48
CoDeSys Visualization
The Placeholder button leads to the 'Replace placeholder' dialog. It lists in the 'Placeholder' column all the placeholders which had been inserted in the configuration dialogs of the "mother"-visualization and offers in the 'Replacements' column the possibility of replacing these for the current instance with a definite value. Which replacements are possible in a given case depends on whether a value group was predefined in the 'Extras' 'Placeholder list' dialog in the "mother"-visualization. If this is the case, it will be displayed in a combo box for selection. If nothing was pre-defined, double clicking on the corresponding field in the Replacements column opens an editing field which can be filled in as desired. A further possibility for replacing placeholders in instances occurs directly when you define the call of visualization by an entry into the Zoom to vis. option field in the configuration dialog ('Input' category).
Note: Note: No control of the chronological sequence of replacements is possible! Therefore no placeholders should be replaced with text that also contains placeholders! When using placeholders it is no longer possible to check for invalid entries in the configuration of the visualization element immediately upon compilation of the project. Hence the appropriate error messages are first issued in Online mode (...Invalid Watch expression..).
CoDeSys Visualization
2-49
Mark the first instance of 'visu' and open the configuration dialog of category 'Visualization'. Press button 'Placeholder', so that the placeholder list will be displayed. There replace entry 'FUB' by 'PLC_PRG.inst_1'. Now mark the second instance of 'visu' and (like described for the first one) replace 'FUB' by 'PLC_PRG.inst_2'. Now in online mode the values of the variables which are used to configure the two instances of 'fu' will be visualized in the corresponding instance of 'visu'. Of course the placeholder $FUB$ can be used at all places in the configuration of 'visu' where variables or text strings are entered. Attention: Online behaviour of a visualization instance: If you insert a visualization and then select and configure this instance, it will be regarded as a single object and in online mode will react to inputs correspondingly to its configuration. In contrast: if you do not configure the instance, then in online mode its particular visualization elements will react exactly like those of the original visualization.
Group The configuration dialog for a group of visualization elements (see Chapter 2.3, Grouping elements) offers the same options Anisotropic, Isotropic, Fixed, Draw, Clip, Color and Alarm color in field 'Frame' as that for a Bitmap (see above). For example regard the possibility to keep the size of the single elements of the group even when the frame gets stretched or compressed.
Dialog Box for Visualization Group Configuration
Special input possibilities for operating versions The CoDeSys visualization can target specifically be used with CoDeSys HMI or as Web- or TargetVisualization as a mere operating interface. Then no menus and status and tool bars will be available to the user and no possibility to modify the code. Thus, when a visualization is created with CoDeSys for the purpose of being used as a 'operating version' the principal control and monitoring functions in a project must be assigned to visualization elements thus making them accessible via mouse click or keyboard in Online mode. See in the following some special input possibilities to configure visualization elements for the purpose of being used in CoDeSys HMI. They are available in the configuration dialog for a visualization element: Enter internal commands in the field Execute program in the category Input according to the following syntax (The dialog 'Configure Programs' is available for this purpose): INTERN <COMMAND> [PARAMETER]* The following table shows the available internal commands. Some of them expect to receive several parameters, which are then entered separated by spaces. Optional parameters are enclosed in square brackets. For those commands which require that a Watch list be specified, a placeholder can
2-50
CoDeSys Visualization
be used instead of the direct name. If you enter several commands for one element, these are separated by commas.
Command Equivalent in the Explanation programming version of CoDeSys Assignment A variable or expression gets assigned to another variable.
Example: INTERN ASSIGN PLC_PRG.ivar1:=PROG1.ivar+12;
ASSIGN <Variable>:=<Expression>
<Path executable program> Program call [Path of the file to be opened] 2 LANGUAGEDIALOG
2)
visualization settings The dialog for visualization settings which includes the
category language gets opened.
LANGUAGE <language identifier as used in the currently set language file *.xml, *.vis, *.tlt or *.txt> LANGUAGE DEFAULT
visualization settings, The desired language is set without using the dialog for
Language visualization settings. See chapter 3 , Language switching in the visualization.
visualization settings, For dynamic texts the default language will be used,
Language
which is defined in the currently included xml-file . See chapter 3 , Language switching in the visualization. The next command will not be executed before this time has elapsed. E.g. a delay of 500 ms is necessary between DEFINERECEIPT, READRECEIPT and SAVEWATCH.
A watch list is selected from the receipt manager which enters your name (name) when the command is given. The variables in this watch list are registered and displayed. In the defined watch list the pre-definition of the variables will be replaced by the current values. Regard: The watch list must be defined before via DEFINERECEIPT and a delay of 500 ms must be inserted ( see above: command DELAY) ! The name of a watch list of the receipt manager is expected. The receipt of this watch list will be written. A previous execution of DEFINERECEIPT is not necessary. The receipt will be read into the current watch list which will be stored in a file. Important: call a previous DEFINERECEIPT to define the current receipt ! Important: call a previous DEFINERECEIPT to define the current receipt and insert a delay of 500 ms (see above: command DELAY) !
'Read receipt'
'Write receipts'
LOADWATCH
'Load watch list'+ 'Write The standard window File open' appears, from which a receipt' previously stored receipt can be selected. This receipt will be immediately written into the controller system. A dialog for setting the user group level will open. The eight CoDeSys user group levels are offered for selection. A dialog for changing the user group password will appear. The project will be saved. The program will be exited. The current visualization will be printed out online.
CHANGEUSERLEVEL
cp. 'Project' 'User Group Passwords...' 'File' 'Save' 'File' 'Close' 'File' 'Print'
CoDeSys Visualization
2-51
Command
Equivalent in the Explanation programming version of CoDeSys Call of a help file Depending on which language is set for the visualization, a help file will be called which is entered for that language in the CoDeSys.ini file. (see 'Extras' 'settings') The window for trace recording (Sampling Trace) will be opened. The menu commands Trace Start, Read, Stop, Save, Load which are available in the full version of CoDeSys are available in this window. If there is a CAMs definition available in the project (Resources), the CAM-Editor will be opened. As soon as the editor will be closed again, it will be returned to the visualization. If there is a CNC program list available in the project (Resources), the CNC editor will be opened. As soon as the CNC editor will be closed again, it will be returned to the visualization.
TRACE 1) 2)
CAM 1) 2)
CAMs
CNC 1) 2)
Only for usage in a Web- or Target-Visualization: The following commands can be used to give the write access in online mode on a visualization to a certain client. This is of interest if multiple clients at the same time might modify data on the PLC. Please see HERE for further information. GETWRITEACCESS RELEASEWRITEACCESS GLOBALRELEASEWRITEACCESS Request for write access Deallocation of the write access which has been requested before Global deallocation of the write access
INTERN LINK <HTTP file path> INTERN LINK mailto:<EMail-Adresse> INTERN CONNECT_TO <PLCName>|<Start-Visu>
2-52
CoDeSys Visualization
2.4.2
'Extras' 'Settings' / Display, Frame, Grid, Language When this command is used, a dialog box will open in which you can make certain settings that affect the display and language of a visualization as well as the check of the visualization variables.
Note: The categories Display, Frame and Language also can be edited in the online mode.
Category Display: Enter a zoom factor into the field Zoom of between 10 and 500 % in order to increase or decrease the size of the visualization display.
Setting dialog for visualizations (Category Display)
Category Frame: If Auto-scrolling is selected, the visible portion of the visualization window will move automatically when you reach the edge while drawing or moving a visualization element. If Best fit in Online mode is selected, the entire visualization including all elements will be shown in the window in Online mode regardless of the size of the window. When Include Background Bitmap is selected, the background bitmap will be fitted into the window as well, otherwise only the elements will be considered.
CoDeSys Visualization
2-53
Category Grid: Define here whether the grid points are visible in the offline mode, whereby the spacing between the visible points is at least 10 even if the entered size is smaller than that. In this case the grid points only appear with a spacing which is a multiple of the entered size. If Active is set, the elements will be placed on the snap grid points when they are drawn and moved. The spacing of the grid points is set in the field Size. Category Compile: Per default the used variables get not checked for validity before going online with a project. If you want this check to be done already during a build run of the project (command 'Project ' 'Build' resp. 'Rebuild all'), then activate option Check visualization variables on compile. Invalid variables will be announced by a warning "... invalid watch expression..." in the message window. Category Language: Here you can specify in which national language the text that you assigned to an element in the Text and Text for Tooltip options should be displayed. Additionally the option 'Dynamic Texts' allows a dynamic change of the displayed text. See chapter 3, Language switching in the visualization.
Note: The text display changes only in Online mode!
'Extras' 'Select Background Bitmap' Use this command to open the dialog box for selecting files. Select a file with the extension "*.bmp". The selected bitmap will then appear as the background in your visualization. The bitmap can be removed with the command 'Extras' 'Clear Background Bitmap'. 'Extras' 'Clear Background Bitmap' Use this command to remove the bitmap as the background for the current visualization. You can use the command 'Extras' 'Select Background Bitmap' to select a bitmap for the current visualization. 'Extras' 'Keyboard usage' The use of hotkeys can optimize the pure keyboard operation of a visualization. In the configuration of a visualization object you can define hotkeys which will cause actions like visualization elements do. For example you could define that if visualization 'xy' is active in online mode the hotkey <Strg><F2> will stop the program, which also will happen as soon as element 'z' of visu 'xy' gets an input (by mouse-click or via touch screen). Anyway per default the keys <Tabulator> <Space> <Enter> will work in that way that in online mode each element of a visualization can be selected and activated. The dialog 'Keyboard usage: set possible keystrokes' can be called in the menu 'Extras' or in the context menu:
Dialog 'Keyboard usage: set possible keystrokes'
2-54
CoDeSys Visualization
In column Key a selection list offers the following keys to which an action can get assigned:
VK_TAB VK_RETURN VK_SPACE VK_ESCAPE VK_INSERT VK_DELETE VK_HOME VK_END VK_PRIOR VK_NEXT VK_LEFT VK_RIGHT VK_UP VK_DOWN VK_F1-VK_F12 0-9 A-Z VK_NUMPAD0 VK_NUMPAD9 VK_MULTIPLY VK_ADD VK_SUBTRACT VK_DIVIDE Tab-Key Enter-Key Space-Key Esc-Key Insert-Key Delete-Key Pos1-Key End-Key Bild ()-Key Bild ()-Key Arrow-Key () Arrow-Key () Arrow-Key () Arrow-Key () Function keys F1 to F12 Keys 0 to 9 Keys A to Z Keys 0 to 9 of the numeric keypad Key* of the numeric keypad Key+ of the numeric keypad Key- of the numeric keypad Key of the numeric keypad
In the columns Shift and Ctrl you can add the <Shift>- and/or the <Ctrl>-key to the already chosen key, so that a key combination will result. See Appendix C for which combinations are supported by the particular visualization variants. In column Action you define what should happen as soon as the key (combination) will be pressed. Select the desired action from the list and insert an appropriate expression. See in the following the available actions and valid expressions, corresponding to those which can be set in the configuration dialog of category 'Input':
Action Toggle Tap true Tap false Zoom Exec Text Meaning Toggle variable Tap variable (set to TRUE) Tap variable (set to FALSE) Zoom to Vis. Execute program Text input of variable 'Textdisplay' Expression Variable, e.g."plc_prg.tvar" Program variable, e.g. "plc_prg.svar" Program variable, e.g. "plc_prg.xvar" Name of the visualization object to which you want to jump, e.g. "Visu1" Name of the executable file, e.g. "notepad C:\help.txt" (Notepad will start and open the file help.txt) Number of the element for which the text input is to be configured, e.g. "#2" (Display of element numbers can be switched on in 'Extras' 'Settings'; also see 'Elementlist...')
CoDeSys Visualization
2-55
In column Expression you must enter depending on the type of action either a variable name, a INTERN-command, a visualization name of a text string, exactly like you would do in the configuration dialog of category 'Input' for the corresponding visualization element. Use button Add to add another empty line at the end of the table. Use the Delete button to remove the line where the cursor is positioned currently. OK resp. Cancel will save resp. not save the done settings and close the dialog. The keyboard usage can be configured separately for each visualization object. Thus the same key (combination) can start different actions in different visualization.
Example: The following key configurations have been done for the visualizations VIS_1 and VIS_2: VIS_1:
Shift x x Ctrl Action Toggle Zoom Key A Z Expression PLC_PRG.automatic VIS_2
VIS_2:
Shift Ctrl Action Exec x Zoom Key E Z Expression INTERN LANGUAGE DEUTSCH PLC_VISU
If you now go online and set the focus to VIS_1, then pressing <Shift><A> will cause that variable PLC_PRG.automatic will be toggled. <Ctrl><Z> will cause a jump from Visu1 to VIS_2. If VIS_2 is the active window, pressing key <E> will cause that the language within the visualization will switch to German. <Ctrl><Z> here will cause a jump to visualization PLC_VISU.
Master layout The usage of a "Master layout" in visualizations for example could be used to provide a dialog in various visualizations without the need to explicitly insert it in each of them. Whether and when the dialog will be displayed in online mode could be controlled via a variable which is defined in the master layout configuration for the visibility of the dialog elements. Use as master layout If a visualization is defined as "Master layout", it will be inserted automatically in all other visualizations (if those are not explicitly excluded, see below) and will be available there with all its functions during online mode. It always will be inserted on the front level, if you however it always want to get it in the background, then activate option in background in the properties dialog of the visualization element (see below). A master layout cannot be edited any longer in the visualization where it has been inserted. Modifications of the configuration only can be done in the master layout visualization itself. Appointing a visualization to be the Master layout is done in the Properties dialog, which can be opened for an object currently selected in the Object Organizer via command 'Project' 'Object' 'Properties' (see CoDeSys User Manual, Chapter 4.3). Option Master layout must be activated for this purpose. If prior to this another visualization has been defined to be a master layout, that one will automatically be re-defined to be a "normal" visualization (option Visualization in the Properties dialog. Visualization without master layout Also in the Properties dialog of a visualization object you can define that it should be used as a Visualization without master layout. Use as Web- or Target-Visualization If a project is created for a Web- or Target-Visualization (see Chapter 8 resp. 9), for each visualization object you can define whether it should be used for this purpose or not.
2-56
CoDeSys Visualization
Thereto select the visualization object in the Object Organizer and open the Properties dialog ('Project' Object' 'Properties', see CoDeSys User Manual, Chapter 4.3). If in the Target Settings the options Web- resp. Target-Visualization are activated, in the Properties dialog the corresponding options Use as Web-Visualization resp. as Target-Visualization automatically also will be activated. In order to explicitly exclude the object from the use in a Web- or Target-Visualization deactivate the appropriate option.
2.4.3
'Extras' 'Bitmap list' In the 'Extras' menu which is available when the Visualization editor is active, command 'Bitmap list' opens dialog 'Bitmap list:...". Here you can enter image files, which then can be used in all visualization objects via a project variable defining the content of a "Bitmap" element. This allows a dynamic change of images in online mode - alternatively to the static use of image files, which for this purpose are not to be part of the bitmap list.
Dialog Bitmap list
In order to enter an image file in the bitmap list, use button Add. The standard dialog for browsing for a file will be opened, where you can select an image file (*.bmp, *.tif, *.jpg, regard the supported file formats, see introductional paragraph of chapter 2.4.3!). If the chosen file is in the project directory, only the file name will be added to the list, otherwise the full path. Via button Delete the currently selected entry (click by the right mouse-button) can be deleted.
CoDeSys Visualization
2-57
In order to modify an entry, either edit it directly (click by the left mouse-button on the entry opens the edit frame), of use button Edit to open the standard dialog for browsing for a file. For the latter the entry first must be selected by a click with the right mouse-button. OK saves the current list. Each file name specified in the list now can be assigned to a variable of type STRING, which is entered in the bitmap configuration of a visualization element in order to define the image to be used. Concerning this please see: Chapter 2.4.1, Configuration of visualization elements, category Bitmap.
2-58
CoDeSys Visualization
3.1
In dialog Visualization settings (see chapter 2.4.2) you configure, which language file should be used with the project. In order to choose a translation (*.tlt, *.txt) or a pure visualization language file (*.vis), which contains the texts in the various languages, activate the Language file option and in the input field next to it enter the appropriate file path. Via the opening a file. button you get the standard dialog for
CoDeSys Visualization
3-1
Regarding creating a translation file *.tlt or *.txt, please see 'Project' 'Translate into other languages' (User Manual for CoDeSys). For creating a special language file *.vis see the following steps: Open likewise the Visualization settings dialog, Language category. Choose option Language file. In the associate input field enter where you want to store the file. The extension is .vis. You also can use the dialog 'Open file' by pressing the button. If a language file with the extension .vis is already present, it will be offered to you here. In the input field next to Language you fill in a keyword for the language which is currently used in the visualization, i.e."german" (or "D") then press the button Save. A file with the extension .vis will be created, which now can be edited by a normal text editor. For example you can open the file by NOTEPAD:
Example of a language file for a visualisation (Category Language)
You get a list of the text variables for the language currently used in the visualization. It includes a reference to the title of this list, for example "1=german" as reference to the title [german]. You can extend the list by copying all lines, then replacing the German by English text and setting a new title [english]. Beyond the line 1=german you accordingly have to add 2=english.
3-2
CoDeSys Visualization
3.2
3.2.1
Configuration
You can control dynamically which text (also alarm message text in an alarm table) will be displayed in a visualization element resp. as tooltip of an element in online mode by using prefix-IDcombinations, each pointing to another text defined in a XML-file (see chapter 3.2.2). For this purpose a XML-file describing the text assignments must be linked to the project in the configuration of the visualization (see chapter 2.4.2, Extras Settings). The XML-file must have a certain format. A language code is added to the particular texts, thus later you not only can switch between different text contents but also language switching is supported. In the configuration of a visualization element, for which the text display should be switched dynamically, Prefix and ID are entered (see below) whereby the ID can be provided by a project variable. A default language can be defined via an INTERN command (see chapter 2.4.2, Special input possibilities for operating versions) So in order to get a dynamic text display, the following entries have to be made in the different configuration dialogs of a visualization: 1. Link the XML-file(s) and choose the (start) language: Dialog 'Settings' category Language: Activate option Dynamic texts and press button Add, in order to link one or several XML-files, which are available on your system, to the project. The selected files will be listed in the window below the button. Press button Delete if you want to remove a selected file from the list. If you want to get displayed just those visualization elements, for which a dynamic text replacement is done, then activate option Hide elements, if no text replacement took place. Selecting one of the language identifiers offered in the selection list at field Language will cause the display of those text versions (for the corresponding prefix-ID-combination) which are marked with that language identifier in the XML.-file.
CoDeSys Visualization
3-3
2. Specify the ID in configuration dialog 'Variables' in field 'Textdisplay' resp. Tooltip-display: Enter here a value (number) resp. a project variable which should define the ID of a text (as used in the XML-file). In case of message texts of an alarm table, the ID must match the respective line number in the table. 3. Define the text format in configuration dialog 'Text' resp. Text for Tooltip: In the Content field, insert a placeholder "%<PREFIX>" at that position of the text, where you want to get displayed a dynamic text in online mode. Instead of "PREFIX" you can enter any string matching with a PREFIX-definition used in the XML-textlist. See the description for the 'Text' configuration dialog. For each prefix-ID-combination, which is found in a linked XML-file, the assigned text will be displayed in the visualization element in online mode. If no appropriate entry is found, no replacement will be done.
3.2.2
3-4
CoDeSys Visualization
In the header section of the file a default language and a default font assigned to a language can be defined. The descriptions in the xml-file are enclosed by tag <dynamic-text> and <\dynamic_text> which have to be entered at the beginning resp. end of the file. The language files for dynamic texts can be created in Unicode (UTF-16) or ANSI (ISO-8859-1). This is to be defined via the encoding syntax at the beginning of the xml-file, e.g. " <?xml version='1.0' encoding='UTF-16'?>". For the preconditions for the usage of unicode-able fonts please see the introductory of chapter 3. See a file example at the end of the chapter.
Please note: - Primary formats of the xml-file, which do not use the <dynamic_text>\<\dynamic_text> tags or the header section, will be supported further on! - The Target-Visualization offers an interface for scanning the entries of dynamic textlists. Thus those can be used directly in the program.
File structure: The header section starts with <header> and is closed with <\header>. If you want to define a default language, use entry <default-language>. A default font which is assigned to a certain language, can be defined via entry <default-font>. These entries are optional. If they are missing, the dynamic text in the visualization will be displayed according to the local configuration settings of the visualization.
<header> <default-language> <language> </defaultlanguage> Default language; that means that if there is no text entry available for the currently set language, that text will be used which is found within the same text entry for the default language. If also for the default language no text is found, "<PREFIX> < ID> will be displayed. If multiple XML-files are used, thus providing multiple headers, only that header section will be regarded, which is read at last. So it is reasonable to use only one header section! The language token must correspond to one of those used in the text entries (see below). Note: In online mode the default language can be set explicitly via a visualization element configured with command INTERN LANGUAGE DEFAULT in category Input, Execute program (see chapter 2.4.1, Special input possibilities for operating versions).
CoDeSys Visualization
3-5
<default-font>
<language><language></language>
Default font for <language>: The given font (e.g. "Arial" will automatically be used for all elements, which display dynamic texts in <language>. The language token must correspond to one of those used in the text entries (see below). For the preconditions for the usage of unicode-able fonts please see the introductory of chapter 3.
<font-name><font></font-name> </default-font> <default-font> <language>...... .... </default-font> </header> further default fonts for other languages
The list of assignments Prefix-ID-text starts with <text list> and ends with </text list>. The particular text entries each start with <text prefix> and end with <\text>. A text entry which is assigned to a Prefix-ID-combination must contain the following lines:
<text prefix>= "<PREFIX> id="<ID>" "PREFIX" corresponds to the <PREFIX> used in the visualization element configuration (category Text or Tooltip); In case of a message text to be displayed in an alarm table the path of the respective alarm group in the alarm configuration as from the System node must be specified, e.g. System/Alarmgroup_1. "ID" for normal texts or tooltip texts corresponds to the entry in category 'Variables', Textdisplay or Tooltipdisplay; in case of an of an message text used in an alarm table the number of the line which defines that text in the configuration dialog of the alarm group must be specified. (See the CoDeSYs V2.3 User Manual for CoDeSys for a description on the Alarm Configuration) Use any string as a 'language' identifier (e.g. "english"). This identifier then will be displayed in the 'Settings' dialog, category Language of the visualization element in the selection list at 'Language'; instead of "TEXT" insert any text which then will be displayed instead of the above defined ID-prefix-combination in the visualization element.
</text>
For each prefix-ID-combination at least for one language a text entry must be available. E.g. see in the file example shown below: <deutsch> indicates the start of the german version of a text, </deutsch> terminates the text. Dynamic texts on the one hand can serve to display texts in different languages, but of course on the other hand they also can be used to change the content of a text (same language) display dynamically.
Example for the use of an language xml-file: You want to have two visualization elements, one for visualizing the current machine identification, the other for visualizing an error message according to a currently given error number: (1) Define in PLC_PRG the following variables: ivar of type INT, defining the current machine identification; errnum of type INT defining the current error number.
3-6
CoDeSys Visualization
(2) Configure a visualization element for displaying the current machine identification: a. b. Enter in category Text in the text field: "%<Maschine>" Enter in category Variables at Textdisplay: PLC_PRG.ivar
(3) Configure another visualization element for displaying the error message for the currently occurred error: a. b. Enter in category Text in the text field: "%<Error>" Enter in category Variables at Textdisplay: "PLC_PRG.errnum
(4) Create a xml-file, e.g. with name dynamictextsample.xml, according to the syntax described above, which should look as follows for the current example: <dynamic-text> <header> <default-language>deutsch</default-language> <default-font> <language>deutsch</language> <font-name> Arial </font-name> <font-color>0,0,0</font-color> <font-height>-13</font-height> <font-weight>700</font-weight> <font-italic>false</font-italic> <font-underline>false</font-underline> <font-strike-out>false</font-strike-out> <font-char-set>0</font-char-set> </default-font> <default-font> <language>english</language> <font-name> Arial </font-name> <font-color>0,0,0</font-color> <font-height>-13</font-height> <font-weight>700</font-weight> <font-italic>false</font-italic> <font-underline>false</font-underline> <font-strike-out>false</font-strike-out> <font-char-set>0</font-char-set> </default-font> </header> <text-list> <text prefix="ERROR" id="4711"> <deutsch> Fehler an Position 4711 </deutsch> <english> Error at position 4711 </english> </text> <text prefix="ERROR" id="815"> <deutsch> Fehler an Position 815 </deutsch> <english> Error at position 815 </english> </text> <text prefix="ERROR" id="2000"> <deutsch> <![CDATA[Das ist ein Fehlertext ber mehrere Zeilen]]> </deutsch> <english> <![CDATA[This is a error text over more than one line]]> </english> </text> <text prefix="MASCHINE" id="1"> <deutsch> <![CDATA[Vorschub]]> </deutsch> <english> <![CDATA[Feed rate]]> </english> </text> <text prefix="MASCHINE" id="2"> <deutsch> <![CDATA[Beschleunigung]]> </deutsch> <english> <![CDATA[Acceleration]]> </english> </text> </text-list> </dynamic-text> (5) In the visualization open dialog Settings, category Language: Activate option Dynamic Texts; Add file dynamictextsample.xml, now available on your computer, to the file list.
CoDeSys Visualization
3-7
(6) Go online with the project. (7) In the visualization settings set language to "deutsch". Set PLC_PRG.ivar to "1" and PLC_PRG.errnum to "4711". Now in the visualization elements the following texts should be displayed: "Vorschub" resp. "Fehler an Position 4711". The texts will be displayed in Arial 13. (8) Set PLC_PRG.ivar to 2 and PLC_PRG.errnum to "2000". The texts will change to "Beschleunigung" and "Das ist ein Fehlertext ber mehrere Zeilen. (9) In the visualization settings change the language to "english". Now the following texts will be displayed: "Acceleration" and "This is an error text over more than one line".
(The change of language also could be managed by using the INTERN command 'LANGUAGE' by another visualization element.)
3.3
3-8
CoDeSys Visualization
4 - Placeholder Concept
Placeholder Concept
At each location in the configuration dialog where variables or text are entered, a placeholder can be set in place of the respective variable or text. This makes sense if the visualization object is not to be used directly in the program, but is created to be inserted in other visualization objects as an "instance". When configuring such an Instance, the placeholders can be replaced with variable names or with text (see chapter 2.4.1, Configuring an inserted visualization", there you also find an example for using placeholders). Any string enclosed in two dollar signs ($) is a valid placeholder (e.g. $variable1$, variable$x$). For each placeholder a value group" can be defined as an input specification in the 'Placeholder list' dialog (called from 'Extras' 'Placeholder list'). With one of these values you can replace the placeholder when configuring an instance of the visualization object. A placeholder list will be available in the instance to do those replacements.
'Extras' 'List of Placeholders...' This list is used at two places in CoDeSys: to manage placeholders and to configure them: 1. primarily you use the list when configuring a visualization object, which later should be inserted, which means instanced, in other visualization(s). For this reason you will use placeholders instead of or additionally to variables and strings in the configuration dialogs. You can open the dialog 'Placeholders' by the command 'List of Placeholders' in the 'Extras' menu or in the context menu. The list shows three columns: 2. Column Placeholder will list all placeholders, which are currently used in the configuration of the visualization object. Column Element number shows the elements which contain a placeholder. In column Replacements you can enter one or several strings (text, variable, expression) which you want to get available later when replacing a placeholder during the configuration of an instance of the visualization object. The elements of the selection must be entered separated by commas. If no or an impossible replacement string is specified, then the placeholder can be replaced with any desired text later during the configuration of the visualization's instance.
Placeholder list for input of possible replacements for the placeholders
3. later you use the list of placeholders when configuring an instance of the above mentioned visualization object, that means after this object has been inserted (as an 'instance') in another visualization by the command 'Insert' 'Visualization'. For this purpose do the following to open the dialog: Select the inserted visualization, execute command 'Extras' 'Configure' and press button 'Placeholders' in Category 'Visualization'. In this case the dialog will only contain two columns:
CoDeSys Visualization
4-1
1-
Column Placeholder like described above shows all placeholders which have been defined for the primary visualization object. If additionally a selection of possible replacements had been defined, this list will now be available in column 'Replacement'. Select one of the entries to replace the placeholder in the present instance. If no replacements have been pre-defined then you can manually enter an expression or variable. For this purpose perform a mouse-click on the field in column Replacement to open an editor field.
4-2
CoDeSys Visualization
5
5.1
Before a download of the project regard the current setting of option 'Prevent download of visualization files' in the target settings. This concerns all files which are used in the current visualization will not be downloaded to the target system. Visualization files are only downloaded for Target- or Web-Visualization and can be bitmaps, language files and for Web-Visualization also XML description files. The configuration settings for Display, Frame and Language can also be edited in online mode. As long as a visualization "instance" is not configured explicitly, the particular elements of the instance in online mode will react on inputs like those of the original visualization ("mother" of the instances). When you switch the language ('Extras' 'Settings') this will only effect the display in online mode. A visualization can be printed in online mode. If a visualization is used as Target-Visualization, information on user entries via mouse-clicks can be scanned with the help of special interface functions and thus be used in the project.
5.2
CoDeSys Visualization
5-1
Additional key (combinations) for the online operation can be defined in the configuration dialog 'Keyboard usage'. There also the keys <Tab>, <Space> and <Enter> can get assigned other functions than the above described standards. The individual elements of instances behave in Online mode identically to the corresponding ones in the visualization that is instanced. They will therefore react the same way as individual elements to inputs and operation by mouse and keyboard; the display of tooltips in instances is also elementdependent. When processing the element list, as for instance when jumping from one input element to the next using the tabulator, the processing of all individual elements of a instance proceeds from the location of the instance in the element list before jumping to the next element of the list.
Note: Operation over the keyboard in online mode is of greatest significance, if the visualization should be used with CoDeSys HMI resp. as Target-Visualization or Web-Visualization! In the Web-Visualization a specific setting in webvisu.htm (see chapter 8.3) allows to keep effective the operation over the keyboard even if currently an entry field is opened.
5.3
RELEASEWRITEACCESS GLOBALRELEASEWRITEACCESS
Automatische Rckgabe des Schreibrechts: Wenn whrend des Monitorings festgestellt wird, dass der aktuell schreibberechtigte Client nicht mehr mit der Steuerung verbunden ist, wird die Variable CurrentWriteAccessClientId auf "-1" gesetzt, was bedeutet, dass kein Client mehr Schreibrecht besitzt. Dies kann auch ber die IEC-Applikation erfolgen.
5-2
CoDeSys Visualization
6 - Visualizations in libraries...
Visualizations in libraries...
Visualizations can also be stored in libraries and thus be made available to projects in the form of library POUs. They can be inserted as instances or they can be called up via the command Zoom to vis." in the input configuration of another visualization which is part of the project.
Note: Visualizations used in a project must have unique names. It can cause errors if for instance a visualization from a library is called or referenced which has the same name as one present in the project, because in processing instances or visualization calls in the program first the visualizations in the project, and only thereafter the ones in the loaded libraries will be implemented.
CoDeSys Visualization
6-1
7 - CoDeSys HMI
7-2
CoDeSys Visualization
7 - CoDeSys HMI
CoDeSys HMI
CoDeSys HMI is the run time system needed for the execution of the well known CoDeSys visualisation. This system enables the user to create inexpensive software for operating machines and plants using the visualisations generated in CoDeSys. CoDeSys HMI uses the already existent project file for the visualisation. Of course it is possible to protect the application program with a read-only protection. The masks then appear in the full-picture mode and merely the visualisation starting with the picture PLC_VISU is shown. All the other operational elements of CoDeSys like menus or the object organiser are not visible. By seamlessly integrating the development platform for the visualisation masks into the PLC programming system CoDeSys HMI offers advantages other visualisations simply cannot come up to: A tag list of the variables to be used is not needed. It is possible to work directly with the CoDeSys variables. Variable values in input fields can be modified by expressions (e.g. Variable1+ Variable2 * 12 + 5) A mighty place-holder concept allows the user to create object-oriented masks. This means the user can build modules similar to the CoDeSys function blocks in the visualisation. The CoDeSys functions Sampling Trace and read/write recipe are also available in CoDeSys HMI.
7.1
/visudownload
/visucompactload
CoDeSys Visualization
7-3
7 - CoDeSys HMI
Please regard: Paths containing spaces must be bordered by quotation marks (").
The project will start in full screen mode with the entrance POU. CoDeSys HMI can be operated corresponding to the functions of the visualization elements via keyboard and mouse. If there is no visualization element configured with a corresponding function, CoDeSys HMI at any time can be terminated by pressing <Alt><F4>.
7-4
CoDeSys Visualization
8 - Web-Visualization
Web-Visualization
The Web-Visualization is a target specific application of a CoDeSys visualization. CoDeSys can create XML descriptions of the visualization objects and download them to the PLC. There a Web-Server will provide the PLC data in XML format too and thus can create a continuously updated visualization which can be opened in the Web Browser of any computer which is connected via Internet, independently from the target platform (e.g. useful for remote maintenance purposes). The Web-Server can connect dynamically to several controllers if configured appropriately. For this purpose the PLCHandler will be used as a basic component of the visualization. Visualization elements can be configured in a way that they will effect a connection change to another target system (see chapter 8.7).
8.1
Preconditions
In order make visualization created in CoDeSys available as Web-Visualization, the following preconditions must be fulfilled: The target system must support the functionality; that means that in the target settings the option 'Web-Visualization' must be activated. If defined in the target file, this can be done by the user in the 'General' target settings. A correctly configured WebServer must be started. (see below) In order to get the Web-Visualization displayed on a computer, a Web-Browser (IE-Explorer or Netscape) is required. Operating system: Windows NT/2000, Windows CE, Linux, RTE
Note: Before a download regard the current setting of option Prevent download of visualization files' in the target settings. This concerns all files which are used in the current visualization. Those can be bitmaps, language files and for Web-Visualization also XML description files.
8.2
CoDeSys Visualization
8-1
8 - Web-Visualization
displayed", "too many variables to be monitored" or the like. Also as a reaction on a download or online change of the project an automatic reload of the Web-Visualization might be defined. The time interval for a cyclic status check can be defined in the file WebVisu.htm (PLCSTATEINTERVAL).
Note: A communication failure during the monitoring of the Web-Visualization will not be dumped as an error message, but will be displayed in the status line of the webbrowser.
8.3
The following parameters can be set to control the behaviour of the Web-Visualization: Width, height - Definition of the size of the screen. Regard the possibility to make visible this size already during creating a visualization in CoDeSys (Target Settings: Display width/height in pixel). STARTVISU - Definition of the start POU (Default: PLC_VISU) UPDATETIME - Definition of the monitoring interval (msec) USECURRENTVISU - Definition whether an automatic change to another visualization will be done, as soon as the system variable 'CurrentVisu' (see chapter 2.1) is changed by the PLC program. (For information on implicit variables see 10.) Optionally the file can be extended by the following entries in the APPLET definition part:
<param name="USEFIXSOCKETCONNECTION" value="FALSE|TRUE">
If this parameter is TRUE, a fix socket connection will be used for monitoring; if it is FALSE or if the entry is missing at all, for each monitoring request a new socket will be used. Default: FALSE. Attention: If parameter USEURLCONNECTION (see below) is used, USEFIXSOCKETCONNECTION may not be set TRUE.
<param name="FORCEDLOAD" value="Comma-delimited visualizations list">
The visualizations specified here will be loaded already when the Web-Visualization is loaded, not just when they are opened for the first time. Thus time is saved at later changes of visualizations, because then the data not have to be transferred first by the WebServer. Examples:
<param name="FORCEDLOAD" value="VISU_1, VISU_2, VISU_3 "> <param name="FORCEDLOAD" value="TREND"> <param name="COMPRESSEDFILES" value="FALSE|TRUE">
8-2
CoDeSys Visualization
8 - Web-Visualization
The files to be transferred for the Web-Visualization to the Web-Server can be provided by CoDeSys in a packed format ("<filename>_<extension original format>.zip"). See for details: CoDeSys User Manual CoDeSys_V23_E.pdf, Target Settings / Visualization. If parameter "COMPRESSEDFILES" is set TRUE, the Web-Visualization first will try to load from the Web-Server all needed files which have got appended the extension .zipand to unzip those. If the request for a zip-file fails, it will be tried to load the original file. If parameter "COMPRESSEDFILES" is not available or is configured with value FALSE, any available zip-files will be ignored.
<param name="USEURLCONNECTION" value="URL">
If this parameter is configured, the communication will be done via the specified URLconnection. Per default a simple socket connection is used. Attention: If parameter USEFIXSOCKETCONNECTION (see above) is set TRUE, USEFIXSOCKETCONNECTION may not be used additionally. Example:
<param name="USEURLCONNECTION" value=http://192.168.100.19:8080/webvisu.htm <param name="SELECTION" value="Line widht|RED|GREEN|BLUE">">
Here the line width and color for the display of the current selection can be defined. Syntax: LINEWIDTH|RED|GREEN|BLUE; Example: 4|0|0|255
<param name="ERROR_SENSITIVITY" value="Number of trials to get a file transferred">">
This parameter defines how many trials will be done to get a visualization file transferred from the Web-Server, before an applet error will appear.
<param name="KEYPADINDIALOGS" value="FALSE or TRUE">">
If a touch panel is used for working with the Web-Visualization, this parameter should be set TRUE in order to get an input possibility in any case for each dialog; if applicable via numpad/keypad.
<param name="KEYBOARDUSAGEFROMDIALOGS" value="FALSE or TRUE">">
If this parameter is set TRUE, the keyboard usage is always active, even if a modal dialog - like e.g. the numpad - is currently opened.
<param name="WRITEACCESSLOCK" value="FALSE or TRUE">">
This parameter only should be set TRUE, if the Web-Server supports multi-client processing and if an access lock for various clients is desired. Concerning access control in multi-client operation please see HERE.
<param name="DEFAULTENCODING" value="FALSE or TRUE">">
If this parameter is set TRUE and the language switching is done via ASCII language files, the default encoding - currently set in the system - will be used for the interpretation of the language file.
<param name="ENCODINGSTRING" value="encoding string">">
If the default encoding of the system is not set as desired, you can define here the desired encoding by entering the appropriate string. Examples for encoding strings: German: "ISO-8859-1" Russian: "ISO-8859-5" Japanese: "MS932"
<param name="PLCSTATEINTERVAL" value="Zykluszeit">">
Cycle time in milliseconds according to which the Web-Client will check the PLC status. It will be checked whether the PLC is in Start or Stop status and whether a download has been done.
<param name="ALARMUPDATEBLOCKSIZE" value="Number of alarm states to be updated per cycle">">
This parameter can be set in order to change the update of the alarm states. Due to the fact that not all alarm states can be updated within one cycle, it might be useful to exactly defined the
CoDeSys Visualization
8-3
8 - Web-Visualization
number of alarms which should be updated per cycle. This number can be specified as a numeric value.
<param name="SUPPORTTOOLTIPSINALARMTABLE" value="TRUE oder FALSE">">
If this parameter is set TRUE, the tooltip functionality in the alarm table will be activated. This means: If any text entry in the alarm table cannot be displayed completely, a tooltip will be available showing the full text string as soon as the mouse pointer is moved on the respective table cell.
<param name="TOOLTIPFONT" value="Schrifttyp|Schriftgre">">
This parameter serves to define the font for all tooltips. Syntax: Font|Size; Example: Arial|11.
<param name="FILEOPENSAVEDIALOGFONT" value="Schrifttyp|Schriftgre ">">
This parameter serves to define the font for the File-Open-dialog. Syntax: Font|Size; Example: Arial|11.
<param name="ALARMTABLEFONT" value="NAME|HEIGHT|WEIGHT|CHARSET|ITALIC|HORZ_ALIGN|VERT_ALIGN">">
This parameter serves to define the font for the alarm NAME|HEIGHT|WEIGHT|CHARSET|ITALIC|HORZ_ALIGN|VERT_ALIGN Example: Arial|11|0|0|false|left|center.
<param name="USECURRENTLANGUAGE" value="TRUE oder FALSE">
table.
Syntax:
If this parameter is set TRUE, the current language setting always will be synchronized between Web- and Target-Visualization (via implicit variable CurrentLanguage); i.e. at a language switch caused by an input in one of the both visualization types each in the other type the language will be switched too. (The CoDeSys Visualization currently is not included in this match).
8.4
8.5
8-4
CoDeSys Visualization
8 - Web-Visualization
-u = Web-Server service gets uninstalled -s = Web-Server service gets started -e = Web-Server service gets terminated The configuration of the server can be done by a configuration file or - restricted usable - by parameters added in the command line when calling the server-exe. The definitions given by a configuration file will overwrite those of the command line. The possible parameters:
webserver-port-nr target-port-nr target-ip-address use-file-upload-dir Port, on which the WebServer expects requests of the client (Web-Browser) Port of the runtime system IP-Address of the runtime system If this flag is set to TRUE, additionally the fileupload-directory (see below, file-upload-dir) must be defined, where the *.xml, *.bmp, *.jpg, etc. files of the Web-Visualization are stored on the target system and from where they are uploaded to the browser. Directory for the Web-Visualization files Type of byte-order (true or false): if "false, the data will get swapped (Motorola Byte-Order). Default: 80 Default: 1200 Default: localhost Default: false
file-upload-dir use-intel-byte-order
The following entries refer to the use of a description file for the PLC-Handler in order to be able to use the MultiPLC-functionality. If these entries are missing, automatically the TCP/IP-connection to the above specified target system will be used. plc-description-file Path of the ini-file for the PLCHandler, describing the communication parameters for all PLCs (controllers) to which the WebServer then can connect via Gateway/PLCHandler.(Per default the ini-file is in the same directory as webserver.exe). If the visualization (Web-Client) via INTERNcommand CONNECT_TO tells to which PLC a connection should be established, this connection will be built automatically by the server and will be maintained until the next change. Section containing the entries <plc-entry> for the various PLCs. Entry for a PLC, contains PLC name and directory. Name of the PLC, PLCHandler.ini-file. as defined in the Default:
plc-entries
Default:
Directory of the PLC files; can be defined absolutely or relatively to the file-upload directory (see above). Example: For the example configuration shown below a definition ".\FD" for the plc-directory results in the following location: "C:\Programme\CoDeSysV23\FD"
Please regard: If you define a "file-upload" directory, where the controller can store the visualization download files, then the visualization files will be automatically updated at each download. The advantage of this upload-directory is that the controller is not involved and thus not strained. The Web Server gets the files directly from the directory and by this the data transfer is much quicker. This is especially of impact in case of a big amount of data.
A configuration file for the Web Server must be available in XML-format and it must be named "webserver_conf.xml". It must be found in the directory where the webserver-exe is. If no
CoDeSys Visualization
8-5
8 - Web-Visualization
configuration file is available, the above mentioned default settings will be used (if not changed by parameters added to the call of the server in a command line.) An example configuration in the webserver_conf.xml file could look as follows:
<webserver-configuration> <webserver-port-nr> 8080 </webserver-port-nr> <target-port-nr> 1200 </target-port-nr> <target-ip-address> localhost </target-ip-address> <use-file-upload-dir> true </use-file-upload-dir> <file-upload-dir> C:\Programme\CoDeSysV23\ </file-upload-dir> <use-intel-byte-order> true </use-intel-byte-order> <plc-description-file> PlcHandler.ini </plc-description-file> <plc-entries> <plc-entry> <plc-name> MASTER </plc-name> <plc-directory> .\MASTER </plc-directory> </plc-entry> <plc-entry> <plc-name> FD </plc-name> <plc-directory> .\FD </plc-directory> </plc-entry> <plc-entry> <plc-name> DL </plc-name> <plc-directory> .\DL </plc-directory> </plc-entry> </plc-entries> </webserver-configuration>
Only these parameters can be used in a command line. The others described above, concerning byteorder and multiPLC-functionality must come via the configuration file. Thus a call corresponding to the above shown configuration example would look like follows, whereby the settings for <plc-description-file> and <plc-entries> must be available in a configuration file: > webserver 8080 1200 localhost c:\Programme\CoDeSysV23
Note: The parameter settings in the command line are without any effect, if there is a valid configuration file available.
8.6
http://localhost:8080/webvisu.htm
WebVisu is the default HTML-file. It contains a <applet> tag which will start the WebVisu-Applet so that the desired start page of the visualization will be displayed. Now you can start to operate the visualization.
Note: If the browser accepts cookies (if necessary, activate this option) the current language setting for dynamic texts will be stored and at the next call of the Web-Visualization will be re-used automatically. If the stored language is not available in the newly opened visualization, the default
8-6
CoDeSys Visualization
8 - Web-Visualization
language of this visualization will be used. If no default language is defined, the visualization texts will not be translated until the language gets switched explicitly.
8.7
Accessing variables
Dynamc indexing within an Array Replacing placeholders containing an expression Array1[Index].a is not possible, however Array1[10].a is possible. The diynamic indexing will be realized with CoDeSys 3.0. Placeholder: $abc$ + 5 Replacement: PLC_PRG.n + 500 -> should result in PLC_PRG.n + 500 + 5, this however is not possible in the Web-Visualization. This function will be realized with CoDeSys 3.0. Pointer variables like PLC_PRG.pdw2^ cannot be monitored. This function will be realized with CoDeSys 3.0.
Pointer variables
Others
Transparent bitmaps Transparent bitmaps are not yet supported.
The following features are only suported by the Web-Visualization: INTERN commands
INTERN LINK Via INTERN LINK <URL> a change to another web page can be defined. (Example: "INTERN LINK http://www.3s-software.com") INTERN LINK <webaddress file> opens a PDF file, which must be available on the server. (Example: "INTERN LINK http://localhost:8080/test.pdf ") INTERN LINK <Email address> opens a window for sending an E-Mail. (Example:"INTERN LINK mailto:[email protected]") The target PLC can be changed if the WebServer is configured appropriately with the connection parameters for multiple PLCs (see Configuration and Start of the Web Server). PLC-Name: Name of the PLC, as defined in the ini-file of the PLCHandler. Start-Visu: Name of the visualization which should be displayed at
CoDeSys Visualization
8-7
8 - Web-Visualization
start of the Web-Visualization. As soon as the WebServer gets the request for a PLC-change, it will automatically establish the connection to the respective PLC. The following diagram shows a possible navigation scenario with multiple PLCs:
If the web browser accepts cookies (if necessary, activate this option) the current language setting for dynamic texts will be stored and at the next call of the Web-Visualization will be re-used automatically. See the note in chapter 8.6.
8-8
CoDeSys Visualization
9 - Target-Visualization
Target-Visualization
The Target-Visualization is one of the possible ways to use a CoDeSys Visualization. CoDeSys can create ST code (Structured Text) for the visualization objects of a project. This code can be downloaded to the PLC together with the normal project code.
Note: Before download regard the current setting of option Prevent download of visualization files' in the target settings. This concerns all files which are used in the current visualization. Those can be bitmaps, language files and for Web-Visualization also XML description files.
Thus, if it is supported by the target system and if an appropriate monitor is available, the visualization can be started directly on the PLC computer. It is not necessary any longer that the programming system is running in order to run the visualization. This means a considerable reduction of storage use.
9.1
Preconditions
The target system must support the functionality; that means that in the target settings the option 'Target-Visualization' must be activated. If defined in the target file, this can be done by the user in the 'General' target settings. The library SysLibTargetVisu.lib (external) is required for implementing the visualization functions in the runtime system. Among other things it provides functions for scanning mouse-actions performed by the user and language depending texts from a dynamic textlist, which thus can be directly used in the program. It will be linked to the project as soon as the option 'TargetVisualization' is activated in the target settings. In the runtime system the SysLibTargetVisu.lib also must be implemented. Regard that also the following, implicitly used libraries will be loaded automatically as soon as the option 'Target-Visualization' is activated: SysLibAlarmTrend.lib, SysLibSockets.lib, SysLibFile.lib, SysLibTime.lib, SysLibMem.lib.) Operating system of the PLC computer: Windows NT/2000, Windows CE. The PLC computer needs devices for displaying and operating the visualization (monitor, keyboard etc.).
9.2
Creating a Target-Visualization
1. Create a visualization in CoDeSys. In order to optimize the performance of the visualization, put as many elements, which are static (no movement, no dynamic texts, no dynamic color changes), to the back. Hint: Using 'Extras' 'Elementlist' several or all elements can be "Sent to back" or "Sent to front" in a single blow. (Explanation: All static elements only once will be drawn to a background bitmap. Thus the cyclic repaint time will be reduced. This will be profitable especially for complex polygons or bitmaps.) A further improvement concerning the performance might be reached by switching off the Keyboard usage for tables (see CoDeSys V2.3 User Manual, App. H, Target Settings in Category Visualization). Please regard also: In order to save memory space when later used in a Target-Visualization, the configuration dialogs for visualization elements might offer restricted color- and font options, defined by manufacturer-specific target settings. If there is a visualization object PLC_VISU, the Target-Visualization later will be started with this object. Otherwise it will start with that object which is the first one in the list of visualization objects in the Object Organizer. Consider whether implicit visualization variables in the current project should be handled as remanent variables and add the appropriate declarations in the Global Variables list (see 9.4).
CoDeSys Visualization
9-1
9 - Target-Visualization
Please regard: For target computers running with Windows NT/2000, Windows CE the bitmaps of the visualization will be transferred as files.
2. For each visualization object, which should not be part of the Target-Visualization, deactivate the option 'Target-Visualization' in the Object Properties dialog ('Project' 'Object' 'Properties') in category 'Visualization'. 3. Make sure that the option 'Optimized jumps' is deactivated in the target settings (Target Platform). 4. In the Target Settings in tab 'Visualization' (it depends on the target system, whether the particular options are available in this dialog!) configure that the project should be prepared for use in the Target Visualization: Activate option Target visualization. Regard also the current setting of option Prevent download of the visualization files' in the target settings. This concerns all files which are used in the current visualization. Those can be bitmaps, language files and for Web-Visualization also XML description files. Additionally here you can define whether the user inputs and the re-painting of the visualization elements.... ... should be controlled via VISU-tasks which are generated automatically or via individual programming: Activate option 'Deactivate task generation'. ... should be processed by one or by two POUs resp. tasks: Activate option 'Use VISU_INPUT_TASK'. (Don't get irritated by the term "..._TASK" in this case; this option is also of effect if no VISU_INPUT_TASK is generated. Please see the descriptions in the following table.) Thus, besides the possibility of deactivating the keyboard usage for table, the following configurations are possible: (a) The Target visualization is controlled by VISU-tasks which are generated automatically and which call the POUs MAINTARGETVISU_PAINT_CODE and MAINTTARGETVISU_INPUT_CODE: Deactivate task generation is switched off:
(a1) Use VISU_INPUT_TASK is activated: Automatically two tasks will be generated, each calling a program:
The default settings of the tasks: - VISU_INPUT_TASK: cyclic, priority 14, interval t#200ms. - VISU_TASK: cyclic, priority 15, interval t#50ms. Of course the parameters can be modified. But: VISU_INPUT_TASK always should be processed before VISU_TASK in order to guarantee a useful interaction of user inputs and update of the visualization. The task calling the main program (e.g. PLC_PRG), should at least be processed as often as VISU_INPUT_TASK, ideally even with a higher priority, but it also could be added directly to VISU_INPUT_TASK.
9-2
CoDeSys Visualization
9 - Target-Visualization
(a2)
Use VISU_INPUT_TASK is deactivated: Only task VISU_TASK will be generated automatically, but in this case will include the functionality of VISU_INPUT_TASK. The implicit program POU MAINTARGETVISU_ PAINT_CODE in this case additionally will include the functionality of program MAINTTARGETVISU_INPUT_CODE. This configuration is intended for systems which do not allow multi-tasking. Disadvantageously no differentiated cycle times can be configured for the processing of user inputs and the repainting of the visualization elements, see above.
(b) The Target visualization is not controlled by automatically created tasks; the implicitly available POUs MAINTARGETVISU_PAINT_CODE and MAINTTARGETVISU_INPUT_CODE can be called by the application program resp. can be appended to any task: Deactivate task generation is activated:
(b1) If additionally option Use VISU_INPUT_TASK is activated, both implicit POUs are available and can be called individually resp. can be appended to any task. (Referring to this regard the hints in (a1). n:=n+1; IF n=(n MOD 4) THEN MAINTARGETVISU_INPUT_CODE(); END_IF; MAINTARGETVISU_PAINT_CODE(); Example for calls of the Target-Visulization POUs in the application program: Here in program visu_control the POU which processes the user inputs is only called after each fourth call of the repainting POU - thus reducing the danger of getting disturbed the repainting by another user input. When creating the application program, absolutely pay attention to reduce this danger of incorrect display ! Example for use of any desired task for controlling the Target visualization POUs; here the above shown program visu_control is called by task visu.
If option Use VISU_INPUT_TASK is not activated, only the implicitly available program POU MAINTARGET VISU_PAINT_CODE can be used, but in this case it will additionally include the functionality of MAINTARGET VISU _INPUT_CODE. This POU can be called in the application program resp. can be appended to any task.
CoDeSys Visualization
9-3
9 - Target-Visualization
9.3
9.4
Return value: FALSE No text matching stPrefix and dwID was found. TRUE - A text matching stPrefix and dwID was found. Function GetTextByStringId : BOOL This function - like function GetText - can provide a language depending text from the currently used dynamic textlist. The difference to GetTest is: The ID of the text entry is given as a string in parameter stID instead of a numeric value. Thus it is also possible to use IDs which are defined as strings in the xml-file for the dynamic texts (e.g. Text123).
stResult: STRING(256); nResultLength:INT; stPrefix: STRING; stID: STRING Serves as an IN_OUT parameter and gets assigned the text found by prefix string stPrefix and ID stID. Define here the maximum length of the string stResult, if this is <256 characters. Prefix of the text entry in the currently used dynamic textlist. ID of the text entry in the currently used dynamic textlist.
Return value: FALSE No text matching stPrefix and stID was found. TRUE - A text matching stPrefix and stID was found.
9-4
CoDeSys Visualization
9 - Target-Visualization
Function GetLastMouseDownEvent : BOOL This function provides information on the last performed MouseDown Event. It contains a pointer (pMouseEvent : POINTER TO MOUSEEVENT;) on structure MouseEvent consisting of the following parameters:
dwCounter : DWORD; Number of MouseDown-Events since system start. With this parameters it can be evaluated whether no, one or multiple events have been prompted since the last request. Last mouse position in X/Y-coordinates.
Return value: No return value. Function GetLastMouseMoveEvent : BOOL This function provides information on the last performed MouseMove-Event. It contains a pointer (pMouseEvent : POINTER TO MOUSEEVENT;) on structure MouseEvent, see above:function GetLastMouseDownEvent. Return value: No return value. Function GetLastMouseUpEvent : BOOL This function provides information on the last performed MouseUp-Event. It contains a pointer (pMouseEvent : POINTER TO MOUSEEVENT;) on structure MouseEvent, see above: function GetLastMouseDownEvent. Return value: No return value.
9.5
Restrictions
Regard the following restrictions when using a visualization created in CoDeSys as TargetVisualization: INTERN commands
PRINT EXITPROGRAM TRACE SAVEPROJECT Printout of the current visualization is not possible. This command is not supported. This command for opening the Sampling Trace window is not supported. This function will be taken by the Trend element. This command for saving the project is not usable for the Target-Visualization.
Grafic formats
In the Target-Visualization currently only simple bitmaps are supported. Not yet supported formats: .jpg, .tif, .ico
Texts
Clipping Texts exceeding the borders of an element currently do not get clipped.
Alarm handling
Actions Actions Print and Message currently are not supported. An appropriate warning will be dumped when compiling the project. The sorting within the alarm table, displayed via button 'History', always is according to date. The settings as done in the configuration of the alarm table element are not regarded.
CoDeSys Visualization
9-5
9 - Target-Visualization
Trend
Degree of accuracy The degree of accuracy can be defined for the horizontal axis. This effects that the number of readout points in the "duration" area can vary. The number of readout points results from: Number of readout points = Duration/Degree of accuracy The number of readout points on some devices effects that the cycle time for VISU_TASK exceeds 200 ms, which will lead to a CPU load of 100% !
Others
Slider in table Zoom to vis. The slider for scrolling is not displayed. 'Zoom to vis.' will not work in Target-Visualization, if placeholders are used.
Input on elements behind If a transparent rectangle, polygon or ellipse element lies on another element, the transparent elements subjacent element will be reached by a mouse-click on the transparent area of the overlying element, like it would be positioned behind an inserted visualization reference. This is different to the default behaviour in all other visualization types: There you can click through visualization references, but not through transparent rectangles, polygons etc.
9-6
CoDeSys Visualization
Appendix A
10
APPENDIX
Implicit Variables in the Visualization
Appendix A
Currently usable in
Simula tion Target Visu Web Visu
String[40]
Name of the currently opened visualization. If the name gets changed, a change to another visualization will be done. Note: With compiler versions < V2.3.7.0, and if the library SysLibStr.lib is not included in the project, the name string MUST be defined in capital letters. Name of the previously opened visualization. Is used for the ZOOMTOCALLER functionality. Only set and automatically modified in a TargetVisualization. Currently set language, available in the language file. The language. Only set and automatically modified in a Target-Visualization. Currently set user level 0..7. All passwords which are defined in CoDeSys in "Usergroup passwords.
CurrentCaller
String[40]
CurrentLanguage
String[40]
CurrentUserLeve * CurrentPasswords[0 .. 7] *
x x
x x
x x
x x
CurrentWriteAccessClientId DWORD
ID of the visualization client which currently has the write access on the PLC data (see Kap.5.4). ID of the current visualization client (see Kap.5.4).
CurrentClientId
DWORD
Implicit variables as remanent variables: The implicit variables CurrentLanguage, CurrentUserLevel and CurrentPasswords[0..7] can be declared as remanent variables for the use in a Target-Visualization. For this purpose the variables must be declared explicitly as global variables. This declaration MUST be done in the topmost global variables list in folder 'Global Variables' in the Resources tab. If the declaration is placed in another global variable list, a compile error will occur.
Example: VAR_GLOBAL RETAIN VisuDoExecuteUserlevelInit : BOOL := TRUE; CurrentUserLevel : INT := 0; CurrentPasswords : ARRAY[0..7] OF STRING[20] := 'a','b','c','d','e','f','g','h'; END_VAR
CoDeSys Visualization
10-1
Appendix A
* Regard for the variables CurrentUserLevel, CurrentPasswords[...]: Those must be of the same type (normal, RETAIN, PERSISTENT...)! If they are defined as remanent variables, additionally a variable "VisuDoExecuteUserlevelInit" of type BOOL must be declared as a RETAIN variable in the global variables list, initialized with TRUE (" VisuDoExecuteUserlevelInit : BOOL := TRUE;").
10-2
CoDeSys Visualization
Appendix B
Appendix B
See in the following an example of a source file of a Dll used for an ActiveX-Element in the CoDeSys visualization. This sample dll will only call the methods GoBack or GoForward of the control if this supports the IWebBrowser interface (see chapter 2.4.1, ActiveX-Element). The method is chosen by the parameter pszId.
#include "stdafx.h" #include <unknwn.h> #include <exdisp.h> BOOL APIENTRY DllMain( HANDLE hModule, DWORD ul_reason_for_call, LPVOID lpReserved ) { return TRUE; } extern "C" __declspec (dllexport) void ExecuteActiveXCall(IUnknown* pUnk, char* pszId, char* pszParam, char* pszReturnBuffer, int nReturnBufferSize, DWORD* pdwReturnFlag) { if (strcmp(pszId, "IWebBrowser|GoBack") == 0) { IUnknown* pNewUnk; IWebBrowser* pwb; pUnk->QueryInterface(IID_IWebBrowser, (void**) &pNewUnk); pwb = (IWebBrowser*) pNewUnk; if (pwb) { pwb->GoBack(); pwb->Release(); } } else if (strcmp(pszId, "IWebBrowser|GoForward") == 0) { IUnknown* pNewUnk; IWebBrowser* pwb; pUnk->QueryInterface(IID_IWebBrowser, (void**) &pNewUnk); pwb = (IWebBrowser*) pNewUnk; if (pwb) { pwb->GoForward(); pwb->Release(); } } }
CoDeSys Visualization
10-3
Appendix B
10-4
CoDeSys Visualization
Appendix C
Appendix C
The table below shows all key combinations usable for keyboard usage (see chapter 2.4.2) in the particular visualization variants. The following abbreviations are used: C TV for CoDeSys/CoDeSysHMI for Target-Visualization
WV for Web-Visualization
If an abbreviation is displayed in a column, the corresponding key (combination) is supported by the concerning visualization variant. The comments for the particular lines you find below in a subsequent table.
no modifier VK_TAB VK_RETURN VK_SPACE VK_ESCAPE VK_INSERT VK_DELETE VK_HOME VK_END VK_PRIOR VK_NEXT VK_LEFT VK_RIGHT VK_UP VK_DOWN F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 0 1 2 3 4 C C / TV C / WV C / TV / WV C / TV C / TV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV C / TV / WV C / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV Shift C C / TV C / WV C / TV / WV C / TV C / TV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV C / TV / WV C / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV C / TV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV C / TV / WV C / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV C / TV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV C / TV / WV C / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV K2 K1 Ctrl C C / TV C / WV Shift+Ctrl C C / TV C / WV K4;K5 K3 comment K4
CoDeSys Visualization
10-5
Appendix C
no modifier 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z VK_NUMPAD0 VK_NUMPAD1 VK_NUMPAD2 VK_NUMPAD3 VK_NUMPAD4 VK_NUMPAD5 VK_NUMPAD6 VK_NUMPAD7 VK_NUMPAD8 C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV
Shift C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV
Ctrl C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV
Shift+Ctrl C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV
comment
10-6
CoDeSys Visualization
Appendix C
Shift C / TV / WV C / TV / WV C / TV / WV C / TV / WV C / TV / WV
Ctrl
Shift+Ctrl
comment
C / TV / WV C / TV / WV C / TV / WV C / TV / WV
C / TV / WV C / TV / WV C / TV / WV C / TV / WV
K1 K2 K3 K4 K5
In CoDeSys additionally the online help will be opened In the Web-Visualization and the IExplorer the File Menu will be opened Ctrl/Esc opens start menu , Shift/Ctrl/Esc opens TaskManager Tab and Space have a different function in the Target-Visualization Shift/Space opens the applet configuration
CoDeSys Visualization
10-7
Appendix C
10-8
CoDeSys Visualization
Appendix C
Index
A
Access protection for vizualization 5-2 Access rights in Visualization 2-22 Acknowledge variables 2-39 ActiveX-Element Condition for call 2-32 Configuration 2-31 Dll for Call 2-32, 10-3 Insert 2-5 Method call 2-32 Variable for URL 2-32 Alarm class 2-39 Alarm handling Target.-Visualization 9-5 Alarm handling Web-Visualization 8-7 Alarm table 2-6 Alarm table configuration 2-39 ALARMTABLEFONT 8-4 ALARMUPDATEBLOCKSIZE 8-3 Align 2-8 Angle 2-11 array indexing 8-7 Array 2-27, 2-38 ASSIGN 2-51 COMPRESSEDFILES 8-2 Configuration 2-10 Configuration of a Web-Server 8-4 Configure programs 2-22 Configure Visualization 2-9 Configure visualization elements 2-10 Copying Visualization Elements 2-7 Create visualization 2-2 CurrentCaller 10-1 CurrentClientId 10-1 CurrentClientId 5-2 CurrentLanguage 10-1 CurrentPasswords 10-1 CurrentUserLevel 10-1 CurrentVisu 10-1 CurrentWriteAccessClientId 10-1 CurrentWriteAccessClientId 5-2 Curve 2-3
D
Data array 2-27 Deactivate task generation 9-2 Default font 3-5 Default language 3-5 DEFAULTENCODING 8-3 DEFINERECEIPT 2-51 DELAY 2-51 Display in visualization 2-53 download Web-Visualization 8-1 Dragging Visualization Elements 2-7 dynamic images 2-47 dynamic language switching 3-3 dynamic texts 3-3 dynamic texts.lib 9-4
B
Background Bitmap 2-54 Bar Display 2-5 Bar Display in Visualization 2-37 bitmap 2-57 Bitmap 2-4, 2-47, 2-54 Bitmap configuration 2-47 bitmap list 2-47 Bitmap list 2-57 Bitmap variable 2-47 bitmaps Web-Visualization 8-7 bmp-file 2-57 Button 2-4
E
Elementlist 2-8 Ellipse 2-3 ENCODINGSTRING 8-3 error messages for Web-Visualization 8-1 error_ini.xml file 8-1 ERROR_SENSITIVITY 8-3 Execute program 2-22, 8-7 EXIT 9-5 EXITPROGRAM 2-51, 8-7 Extras Align 2-8 Bitmap list 2-57 Clear Background Bitmap 2-54 Configure 2-10 Elementlist 2-8 Group 2-7 Keyboard Usage 2-54 List of placeholders 4-1 Select 2-7 Select All 2-7 Select Background Bitmap 2-54 Send to Back 2-8 Send to Front 2-8 Settings 2-53 Ungroup 2-8
C
CAM 2-52 CHANGEPASSWORD 2-51 CHANGEUSERLEVEL 2-51 Changing the Selection and Insert Mode 2-7 Check visualization variables on compile 2-54 Clear Background Bitmap 2-54 CNC 2-52 CoDeSys HMI 7-3 CoDeSys HMI Special configuration possibilities in Visualisation 250 CoDeSys HMI 2-50 COLCONST 2-28 Color in visualization elements 2-10 Color Variables in Visualization 2-17 Colors in Visualization 2-16 Columns 2-39
CoDeSys Visualization
Appendix C
F
File Print in online mode 5-2 FILEOPENSAVEDIALOGFONT 8-4 Font Unicode 3-1 Font in visualization elements 2-10 FORCEDLOAD 8-2 Formatting strings 2-12 Frame 2-53
INTERN CONNECT_TO 8-7 INTERN GETWRITEACCESS 2-52, 5-2 INTERN GLOBALRELEASEWRITEACCESS 2-52, 5-2 INTERN LINK 8-7 INTERN LINK 2-52 INTERN RELEASEWRITEACCESS 2-52, 5-2 Invisible scrollbar 2-34
J
jpg-file 2-57
G
GetLastMouseDownEvent 9-5 GetLastMouseMoveEvent 9-5 GetLastMouseUpEvent 9-5 GetText 9-4 GetTextByStringId 9-4 GETWRITEACCESS 2-52 GETWRITEACCESS 5-2 GLOBALRELEASEWRITEACCESS 2-52, 5-2 Grid 2-54 Group configuration 2-50 Grouping visualization elements 2-7, 2-50
K
key combination 10-5 Keyboard operation 5-1 keyboard usage 10-5 Keyboard usage in Visualization 2-54 KEYBOARDUSAGEFROMDIALOGS 8-3 KEYPADINDIALOGS 8-3
L
language 3-3 Language 3-5 LANGUAGE 2-51 LANGUAGE DEFAULT 2-51 language file 3-2 Language in visualization 2-54 language setting in Web-Visualization 8-6 language switching 9-4 language switching 3-1, 3-3 language switching configuration 3-3 LANGUAGEDIALOG 2-51, 8-7 Line width in Visualization 2-15 LINK 2-52 List of placeholders 4-1 LOADWATCH 2-51
H
height of visualization screen 8-2 HELP 2-52 Help file in Visualization 3-8 Hide elements, if no replacement took place 3-3 Histogram 2-6 Histogram configuration 2-38
I
ID 3-3, 3-4 image file formats 2-57 images for dynamic switching 2-57 images in visualization 2-57 Implicit Variables 10-1 INDEX 2-28 Input 2-21 input on transparent elements 9-6 Insert ActiveX-Element 2-5 Alarm table 2-6 Bar Display 2-5 Bitmap 2-4 Button 2-4 Curve 2-3 Ellipse 2-3 Histogram 2-6 Meter 2-5 Pie 2-3 Polygon 2-3 Polyline 2-3 Rectangle 2-3 Rounded Rectangle 2-3 Table 2-5 Trend 2-6 Visualization 2-4 WMF file 2-5 Insert Metafile 2-5 Instance of a visualization 2-10
M
MAINTARGETVISU_INPUT_CODE 9-2 MAINTARGETVISU_PAINT_CODE 9-2 Master layout 2-56 Metafile 2-5 Meter 2-5 Meter element in Visualization 2-34 Method call 2-32 Modifying Visualization Elements 2-7 Motion absolute in Visualization 2-18 Motion relative in Visualization 2-19 MouseEvent 9-5 Mulit-Client Visualization 5-2
O
Object properties 2-56 online change Web-Visualization 8-1 Online Help in visualization 3-8 Online Mode Visualization 5-1 Online Mode 5-1 Operating version 2-50 Operation over the keyboard in online mode 5-1
CoDeSys Visualization
Appendix C
P
Password \* MERGEFORMAT 10-1 Pie 2-3 Placeholder 2-10, 2-49, 8-7 Placeholder Concept 4-1 Placeholder List 4-1 Placeholders in Target-Visualization 9-6 PLC_VISU 8-4, 9-1 PLCSTATEINTERVAL 8-3 pointer variables in Web-Visualization 8-7 Polygon 2-3 Polyline 2-3 Position 2-8, 2-9 PREFIX 3-3, 3-4, 3-6 Prefix-ID-combination 3-4 Prefix-ID-combination 3-3 PRINT 9-5 PRINT 2-51, 8-7 Print in online mode 5-2 Programmability 2-23 Properties of visualization object 2-56
T
Table Target-Visualization 9-6 Table 2-5, 2-27 Table element configuration 2-27 Tap FALSE 2-21 Tap variable 2-21 Target Settings Target-Visualization 9-2 Target-Visualization Activate 9-2 Implicit Variables 10-1 PLC_VISU 9-1 Target-Visualization 2-56, 9-1 Template for table element 2-28 Text 9-5 Text 2-12 Text in Visualization 2-12 textlist 9-4 Textvariables in Visualization 2-14 tif-file 2-57 tlt-Datei 2-51 tlt-file 3-1 tlt-file 3-2 Toggle variable 2-21 ToolTip in Visualization 2-22 Tooltip-display 2-34 TOOLTIPFONT 8-4 TRACE 9-5 TRACE 2-52, 8-7 translation file 3-2 Translation file Visualization texts 2-12 transparent bitmaps 8-7 transparent visualization element 9-6 Trend Target-Visualization 9-6 Trend 2-6, 2-42 Trend configuration 2-42
R
READRECEIPT 2-51 Rectangle 2-3 Reference 2-10 RELEASEWRITEACCESS 2-52, 5-2 reload of Web-Visualization 8-1 Remanent variables for Target-Visualization 10-1 Replace placeholder 2-49 Rounded Rectangle 2-3 ROWCONST 2-28
S
SAVEPROJECT 9-5 SAVEPROJECT 2-51, 8-7 SAVEWATCH 2-51 Scrollbar 2-33 Security in Visualiszation 2-22 Select 2-7 Select All 2-7 Select Background Bitmap 2-54 Selecting elements in Visualization 2-7 Selecting Visualization Elements 2-6 SELECTION 8-3 Send to Back 2-8 Send to Front 2-8 Settings in visualization 2-53 Shape 2-11 Simplified input handling 5-1 Slider 2-34 Slider 2-39 Slider size 2-27 STARTVISU 8-2 static language switching 3-1 Status Bar 2-9 status check for Web-Visualization 8-1 SUPPORTTOOLTIPSINALARMTABLE 8-4 switch images 2-57 SysLibTargetVisu.lib 9-4 SysLibTargetVisu.lib 9-1 System Variables 10-1
U
Unicode 3-1 UPDATETIME 8-2 URL 2-32 URL-connection for Web-Visualization 8-3 Use as master layout 2-56 Use as Target-Visualization 2-56 Use as Web-Visualization 2-56 Use VISU_INPUT_TASK 9-2 USECURRENTVISU 8-2 USEFIXSOCKETCONNECTION 8-2 User level 10-1 USEURLCONNECTION 8-3
V
Variables in Visualization 2-20 vis-Datei 2-51 vis-file 3-1 vis-file 3-2 Visualisation Input possibilities for CoDeSys HMI 2-50 Visualization Compile 2-54 Display 2-53
CoDeSys Visualization
Appendix C
Frame 2-53 Grid 2-54 Insert 2-4 Instance 2-10 Language 2-54 Master layout 2-56 Placeholder 2-10 Visualization as Visualization element 2-48 Visualization Editor 2-1 Visualization Elements 2-2 visualization files 5-1, 9-2 visualization name 2-2 Visualization Object Configure... 2-53 Visualization without master layout 2-56 VisuDoExecuteUserlevelInit 10-2
Web-Visualization Auto-Reload 8-1 language setting 8-6 PLC_VISU 8-4 status check 8-1 WebVisu.htm 8-2 Web-Visualization 2-50, 2-56, 8-1 width of visualization screen 8-2 WMF file 2-5 Write access for visualization clients 5-2 WRITEACCESSLOCK 8-3 WRITERECEIPT 2-51
X
xml-file for dynamic texts 3-4
W
Web Server Configuration and Start 8-4 Configuration file 8-5 File upload directory 8-5 webserver_conf.xml 8-5 WebVisu.htm 8-2
Z
zip-files for Web-Visualization 8-2 Zoom to vis. 9-6 Zoom to Vis. 2-21, 2-49 ZOOMTOCALLER 10-1
CoDeSys Visualization