API 650 Tank Design Calculation
API 650 Tank Design Calculation
1 Service : 2 Location :
Equipment No. :
Kirwin
Mfr Ref. No. :
Design Engineer :
Model : 3 Manufacturer : 4 P&ID No. PID115-EPF-01-112A1 Plot Plan No. : 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Shell Diameter : 25 Roof Type : 26
Two
M G
50.00 Ft H 32.00 Ft E L F N1
50.00 Cone
Feet Shell Height : 48" X 48" FLUSH CLEANOUT
E D
N2
32.00
J
Feet
I
Nominal Volume :
11,191
Barrels
Sloped
NOZZLES/CONNECTIONS Qty 2 2 1 1 1 1 1 1 1 1 1 1 1 1 Size 24" 24" 48"x48" 6" 1" 8" 10" 30" 4" 8" 3/4" 3/4" 4" 2"
OPERATING/DESIGN DATA
0.7900
Mark A E F G H I J K L M N1 N2 P D
Service Roof Manway Shell Manway Flush Cleanout MW Stilling Vent Temperature Indicator Outlet Nozzle Fill Nozzle Mixer Manway Water Draw Nozzle Top Center Vent Sample Tap Sample Tap Roof Nozzle Spare
psia 5.5 29 Vapor Pressure @ Max. Operating Temperature Design 30 Flash Point (Closed Cup) : F Operating 31 Negative Pressure 32 Positive Pressure oz/in.2 psig F F Yes Set @ CA, in. 0.1250 0.1250 0.0.3 0.00 1.00 0.50 2.00
33 (Hydro)test Pressure expressed in Psig 34 Minimum Fluid Temperature 35 Maximum Fluid Temperature 36 Emergency Vacuum Design ? 37 38 Component 39 Shell & Bottom 40 Roof 41 Lining/Coating 42 43 Stress Relieve ? 44 45 Code (as appl.): 46 Design Specifications: 47 Tank Insulation ? 48 Insulation Type: 49 Fireproofing ? 50 Remarks 51 52 No Hot Yes for: Material 57370 516 Grade 55
----25 200
oz/in.2
Rating 150# 125# 125# 125# 150# 150# 150# 150# 150# 150# 150# 150# 150# 150# 150# 150#
Others: 100 Yes
CONSTRUCTION/FABRICATION
Internals (attach separate sheet, as req'd): Sump Seismic Zone Radiograph 85 EmptyTank Weight
mph lb
Yes
1. Items marked with an asterisk (*) to be completed by Vendor/Fabricator. 2. Fixed cone roof with internal floating roof.
Approvals
Rev 0 Date Description For Inquiry By Chk. Appr. Rev Date Description By Chk. Appr.
Rev. No.
Sheet
1 of 1
Art Montemayor
FROM ( BOTTOM COURSE) PLATE TO (TOP COURSE) PLATE td = 2.6(D)(H -1)(G)/Sd= 0.174 in. Wall Thickness
Miniumum shell thickness, in inches, td = td / tt = 2.6(D)(H-1)/(St) td = 0.224 in. (Includes Corrosion Allowance) G = design Specific gravity of liquid Sd = allowable Stress for Design condition E = joint efficiency St = allowable stress 516-60 Hydro Test CA = Corrosion Allowance For First Course (Bottom) 516-60 Plate td = 2.6(D)(H -1)(G)/Sd = td =td / tt = 2.6(D)(H-1)/(St) = td = Miniumum shell thickness, in inches = D = Normal tank diameter , in feet = H = depth of tank , in feet = G = design Specific gravity of liquid = Sd = allowable Stress for Design condition E = joint efficiency St = allowable stress516-60 Hydro Test CA = Corrosion Allowance For Second Course 516-60 Plate td = 2.6(D)(H -1)(G)/Sd= td =td / tt = 2.6(D)(H-1)/(St) td = Miniumum shell thickness, in inches D = Normal tank diameter , in feet H = depth of tank , in feet G = design Specific gravity of liquid Sd = allowable Stress for Design condition E = joint efficiency St = allowable stress 516-60 Hydro Test CA = Corrosion Allowance For Third Course 516-60 Plate 0.209 50.00 28 1 21,300 0.85% 24,000 0.0625 0.3750 0.230 50.00 32.00 1 21,300 0.85% 24,000 0.0625 0.5000 0.165 1 23,200 0.85% 24,900 0.0625 0.236 0.189
Page 2 of 8
Art Montemayor
2 5,027 Ft of Shell surface area 2 1,963 Ft of Roof Area (estimated) 2 1,963 Ft of Bottom Floor area
Page 3 of 8
Tank is unanchored, use equations pertaining to unanchored tanks, for seismic loading. DATA GIVEN: Seismic Zone; Zone Coefficient Importance Factor Diameter of Tank Height of Liquid Content (Design) Shell Height Design Specific Gravity Thickness of Bottom PL Under Shell Yeild Strength of Bottom PL Weight of Shell Weight of Roof + Live Load = 107.4 + 210.4 PI()/4(94.5)2 (44.5)(.79)(62.4) Weight of Product CALCULATIONS: Seismic Coefficients: Xs = C1 = D/H = Per Fig. E-2 W1 / Wt = W2 / Wt = Per Fig. E-3 X1 /H = X2 /H = Per Fig. E-4 K = 0.6 Lateral Force Coefficients: T =K (D 0.5 ) =.6 *(94.5 0.5) = If Greater Than 4.5 seconds 3.375 (s/T2) = 3.375*1.5/5.832 = E-3.3 5.83 Seconds 0.149 Seconds 0.375 0.59 X1 = X2 = 16.7 26.3 0.535 0.45 W1 = W2 = 8,231 6,924 19.685 Ft 0.60 2.12 3 0.3 1.0 94.5 44.5 48 0.79 0.3750 36,000 221 317.8 15,386 PSI Kips Kips Kips
Z= I = D= H= Hs = G= tb = Fby = Ws = Wy = Wt =
Page 4 of 8
M = (Z)(I) { (C1)(Ws)(Xs)+(C1)(Wr)(Ht)+(C1)(W)(X)+(C2)(W 2)(X2)} (0.3)*(1.0)[ 0.6(221)(19.685)+ 0.6(317.8)(48.0)+ 0.6(8232)(16.7)+ 0.149(6924)(26.3)] 0.3 2610 9155 82485 27133 36415 Ft-Kips V = (Z)(I) {(C1)(Ws)+(C1)(Wr)(Ht)+(C1)(W)(X)+(C2)(W2)(X2)} (0.3)*(1.0)[ 0.6(221)+ 0.6(317.8)+ 0.6(8232)+ 0.149(6924)] 0.3 132.6 190.68 4939.2 Reistance to Overturning:( E.4.1) API 650
W L = 7.9tb Fby G H (G18)*(G16)*(G14)/(G13)2 )
1031.676
1888 kips
3,333 1125
# / ft
Constant = 3,333 # / ft
# / ft # / ft
Wt + W L = 583.8 / (PI()*94.5) + 4.153 M / D2 (Wt + W L) (G76)/(G13)2(6.12) 36415 b = 1.815+1.273*36415/94.5^2 Max. Longitudinal Compressive Force UnAnchored Longitudinal Compressive Stress 7000 / 6 Allowable Longitudinal Compressive Stress GHD2/t2 1.255 * 106 = Fa=106 (t) / D = Anchorage Not Required 54653 b =
Page 5 of 8
Art Montemayor
FOUNDATION DESIGN:
Max. Overturning Moment Due To Seismic Loads. Compression or Tension Due To Moment: Seismic Base Shear: RINGWALL DESIGN: Use Following Weight Values for Materials Wt. of Steel Wt. Of Compacted Soil Wt. Of Concrete Wall Wt. Of Product in Tank Horizontal Pressure on Ring Wall: F=Kah(g*p*H+1/2 soh)+270 0.3*6.0[(50*44.5+0.5*110*6.0)]+270 Hoop Tension: 1/2FD= 1/2(4869)(94.5) As= 231/24.0 USE - 6 # 9 Bars Ea. Face USE - # 4 Bars at 12" on Center Minimum RingWall Thickness: T = 2W / g *p*h - 2h ( gc - gso) (2)(1100)/50(44.5)-2(6.0)(150-110) W = 1100 230 kips 10 in. 490lb/ft3 110 lb/ft3 150 lb/ft3 50 lb/ft3 36,415 Kips 5.19 kpf 0.27 kips
4,869 kips
12"
Page 6 of 8
Art Montemayor
Concrete Tensile Stress: fct = c(Es)(As)+T / Ac + n (As) .0003(29*106)(10)+231000/(16*72)+(9*10) 318000 1242 .15(3000) Soil Bearing: Try 3'- 6" Footing Weight. of Wall = 1.33*5.0*.150 Weight of Footing = 3.5*1.0*.150 Weight of Fill = 2.17*4.0*.110 1.0 0.525 0.95 2.48 kips kips kips kips 256 psi 450 psi OK
Case 1 Load from Shell + Roof + Live Load = Weight of Wall +Footing + Fill = Bearing Pressure = Case 2 Dead + Live Load + Earthquake Load = P = 3.58 + 5.19 = H= Moment at Base of Footing = 8.77 kips 0.270 kips 1.62 kips 3.58/3.50 1.1 kips 2.48 kips 1.0 kips
.270(6.0)
Page 7 of 8
47" - 3"
12"
10" Pad of Sand Well-Compacted Gravel 95% Compacted 50 / 100 % Passing # 4 Sieve # 4 Bars 12" O/C Each Face
10"
4'-0"
NOTES:
1. Oiled sand to be mixture of sand and liquid asphalt (mc70): 2. Use 10 gallons of asphalt per cubic yard of sand: 3. Top of concrete to be smooth and level with 1/8" +/- in any 30 feet of circumferential length: 4. Maximum Deiation to be less than 1/4" overall:
Page 8 of 8