M/s. REI AGRO LIMITED. 2 X 36 MW CAPTIVE POWER PLANT BOILERS (BG059 & BG060)
TABLE OF CONTENTS
SL. NO. II. DESCRIPTION BOILER MOUNTINGS:
WATER LEVEL GAUGE (BI-COLOUR MULTIPORT) WATER LEVEL GAUGE (TUBULAR) LIQUID LEVEL SWITCH SAFETY VALVE (DRUM & STEAM LINE) SAFETY VALVE (SOOT BLOWER) SAFETY VALVE (DEAERATOR) CONTROL VALVE GANG MOUNTED DOUBLE SOLENOID VALVE SOLENOID OPERATED BUTTERFLY VALVES MOTORISED VALVES START UP VENT VALVE MOTORISED ANGLE TYPE BLOW DOWN VALVES VACUUM RELIEF VALVE REGULATING POWER CYLINDER AIR CYLINDER (ON-OFF) 003 016 027 039 047 051 054 071 077 082 102 105 108 111 130
PAGE NO.
BOILER MOUNTINGS
DATA SHEET
SPECIFICATION
OPERATING DATA:
MAX. WORKING PRESSURE HYDRO TEST PRESSURE MAX. WORKING TEMPERATURE 104 Kg/cm2 (g) 158 Kg/cm2 (g) 315C
SUPPLIERS ADDRESS:
M/S. TYCO VALVES & CONTROLS INDIA PVT. LTD, 3-A, 23-C, 3RD FLOOR, NORTH BOAG ROAD, MAHINDRA APARTMENTS, CHENNAI 600 017 T. NAGAR,
DATA SHEET
SPECIFICATION
M/S. CHEMTROLS SAMIL (INDIA) PVT. LTD. DEAERATOR 2 NOS. LG0001 & LG0002 TUBULAR 1200 MM HP& LP DOSING IBD & CBD TANK 2 NOS. LG0003 & LG0501 TUBULAR 800 MM 2 NOS. LG0005 & LG0006 TUBULAR 800 MM TUBULAR 800 MM LDO TANK 1 X 2 NOS. LG1801
MATERIAL OF CONSTRUCTION: VALVE BODY & BONNET MATL. SPINDLE / SEAT & TIP SAFETY BALL HAND WHEEL GASKET PACKING SS 410 / SS 304 OFF SET TYPE CARBON STEEL / SCREWED SS 316 / SS 316 SS 316 / SS 316 SS 316 / SS 316 SS 316 PRESSED STEEL CAF GRAPHITED
SUPPLIERS ADDRESS:
M/S. CHEMTROLS SAMIL (INDIA) PVT. LTD, PLOT NO.R-587/1 , M.I.D.C, TTC INDUSTRIAL AREA, RABALE, THANE BELAPUR ROAD, NAVI MUMBAI - 400 072.
(BOILER BG059)
DATA SHEET
SPECIFICATION
OPERATING DATA:
MAX. WORKING PRESSURE HYDRO TEST PRESSURE MAX. WORKING TEMPERATURE 10.0 Kg/cm (g) 15.0 Kg/cm (g) 250C 8.0 Kg/cm (g) 15.0 Kg/cm (g) 250C
(BOILER BG059)
DATA SHEET
SPECIFICATION
SUPPLIERS ADDRESS:
M/S. CHEMTROLS SAMIL (INDIA) PVT. LTD, PLOT NO.R-587/1 , M.I.D.C, TTC INDUSTRIAL AREA, RABALE, THANE BELAPUR ROAD, NAVI MUMBAI - 400 072.
IINSTRUCTIIONS & MAIINTAIINANCE MANUAL NSTRUCT ONS & MA NTA NANCE MANUAL
IM/LSF-1/2003 REV. 00
OPERATING CYCLE: Level switch consists of float with magnetic attraction sleeve and switch mechanism. As the liquid rises in the vessel, the same level rises in the float chamber, resulting upward movement of float, moving the attraction sleeve within the non-magnetic enclosure tube, into the field of external magnet. Thus magnet gets attracted towards the enclosure tube, which further causes the switch to actuate, Making an electrical circuit. The reverse function takes place, while the liquid level falls down. As the liquid level falls down, the float pulls attraction sleeve downward out of the magnetic field to a predetermined low level, Breaking an electrical circuit, which causes the magnet to release from the enclosure tube against a tension spring, which in turn deactivates the switch.
The packing cases of level switch must not be kept or stored in upright position to avoid damage of float and switch housing casting, that can be happen due to the accidental falling of the packing cases. The packing cases must be protected from direct sunlight and water. While storing the packing cases, ensure that no heavy items are placed over it, which may cause the damage of chamber, switch housing and cooling fins. Individual pieces should be kept properly or stored in manner to avoid damage while awaiting for installation. Care should be taken not to bend or fall down displacer during unpacking or installation, which may cause change in set point, set at factory. The extension rod is extremely fragile, do not handle it in such a way that any amount of load act on the extension rod.
NOTE: RETIGHTEN FLANGE JOINTS AND TEST FOR LEAK TIGHTENESS PRIOR TO START.
TROUBLE SHOOTING
Usually the first indication of improper operation is failure of level switch unit to function : i.e. pump will not start, signal lamp fails to light etc. When such condition happens while installation or during routine service, check the following causes first, Fuse may be blown. Reset button(s) may need resetting. Power switch may be open. Level switch unit may be faulty. Wiring leading to the instrument may be defective. If through inspection of these conditions fails to locate the trouble, proceed next to check the instrument switch mechanism, Pull/ disconnect switch or disconnect power supply. Remove switch- housing cover.
NOTE: As a matter of good practice, spare switches should be kept on hand at all times. If switch mechanism is operating satisfactorily a test of the complete instrument performance is the next likely step. Reconnect power supply if area is non-hazardous and carefully actuate the switch mechanism manually to determine whether level switch unit will operate. If area is hazardous, check with safety engineer before reconnecting power supply. If switch unit responds to manual actuation test, trouble may be located in the level-sensing portion of the instrument displacer attraction sleeve.
NOTE: Check first to be certain liquid is entering float chamber. A valve may be closed or pipeline blocked.
With liquid in tank, proceed to check level sensing action by removing switch-housing assembly. Inspect attraction sleeve, extension rod and inside of enclosure tube for excessive corrosion, bend or solid built up which could restrict movement, preventing attraction sleeve from reaching the field of magnets. If attraction sleeve is corroded clean it or replace it with new one and if extension rod is bent, it must be replaced. Inspect the displacer for dirt, scale build up or for any damage and be certain it is buoyed in the liquid. If float is found to be filled with liquid or collapsed, it must be replaced immediately. Inspect the chamber and process connection for dirt, corrosion, scale build up or for any damage. Inspect the switch mechanism for any damage such as cracks, corrosion, if there is any damage the switch mechanism must be replaced immediately.
DONTS
Do not move the switch mechanism assembly from their position, set in the factory. Do not leave the switch housing cover off the unit longer than necessary to make routine inspection. Do not make adjustments or replacement without reading instructions carefully. Never use lubricants on pivots of switch mechanism. Do not stretch the displacer spring, which may cause changed in set point, set at factory. Do not operate the switch under defective condition.
DATA SHEET
SAFETY VALVE
DESCRIPTION GENERAL:
MAKE TYPE NOZZLE DISC BONNET TYPE LIFTING LEVER
BODY & BONNET MATERIAL
UNIT
---------
SPECIFICATION
M/S. TYCO SANMAR LIMITED. CONVENTIONAL (SEMI NOZZLE) SA351 GRCF8C INCONEL 718 OPEN PLAIN SA216 GR. WCB (DRUM), SA217 GR. WC9 (STEAM LINE) ALLOY STEEL H.T. AL. PTD
SPRING MATERIAL
OPERATING DATA:
QUANTITY TAG NO. Nos. --
DRUM I
1X2 PSV1201 (BG059) PSV2201 (BG060)
DRUM II
1X2 PSV1202 (BG059) PSV2202 (BG060) HCI-56W-IBR-SPL SATURATED STEAM 104 313.1 40000 45633 5.0 2.5 TO 5.0 IBR ASME SEC-I 50 / 100 J2 BUTTWELD
STEAM LINE
1X2 PSV1203 (BG059) PSV2203 (BG060) HCI-98W-IBR-SPL SUPERHEATED STEAM 93.54 525 20000 22615 5.0 2.5 TO 5.0 IBR ASME SEC-I 40 / 100 H2 BUTTWELD
---
Kscg C Kg/hr
103 312.38 40000 45198 5.0 2.5 TO 5.0 IBR ASME SEC-I 50 / 100 J2 BUTTWELD
OVER PRESSURE BLOW DOWN SIZING CODE CODE VALVE INLET/OUTLET SIZE ORIFICE END CONNECTION INLET
END CONNECTION OUTLET
% % --MM ----
SUPPLIERS ADDRESS:
M/s. TYCO SANMAR LIMITED, NO. 9, CATHEDRAL ROAD, CHENNAI - 600 086.
DATA SHEET
SAFETY VALVE
DESCRIPTION GENERAL:
MAKE TYPE NOZZLE MATERIAL DISC BONNET TYPE LIFTING LEVER BODY & BONNET MATERIAL SPRING MATERIAL --------M/S. TYCO SANMAR LIMITED. CONVENTIONAL (FULL NOZZLE) SA351 GR. CF8M SA565 GR. 616 (SS 422) OPEN PLAIN SA216 GR. WCB CHROME STEEL
UNIT
SPECIFICATION
OPERATING DATA:
QUANTITY TAG NO. MODEL NO. MEDIUM SET PRESSURE TEMPERATURE REQD. RELIEVING CAPACITY
ACTUAL RELIEVING CAPACITY
SOOT BLOWER
NOS. ---Kscg C Kg/hr Kg/hr % % --MM ---1X2 PSV1204 (BG059), PSV2204 (BG060) HSJ-35-IBR SUPERHEATED STEAM 24 350 3500 5147 5.0 2.5 TO 5.0 IBR ASME SEC-I 40 / 80 H FLANGED, ANSI B16.5, 300# RF FLANGED, ANSI B16.5, 150# RF
OVER PRESSURE BLOW DOWN SIZING CODE CODE VALVE INLET / OUTLET SIZE ORIFICE END CONNECTION INLET END CONNECTION OUTLET
SUPPLIERS ADDRESS:
M/s. TYCO SANMAR LIMITED, NO. 9, CATHEDRAL ROAD, CHENNAI - 600 086.
(BOILER BG059)
DATA SHEET
SAFETY VALVE
DESCRIPTION GENERAL:
MAKE TYPE NOZZLE MATERIAL DISC BONNET TYPE LIFTING LEVER BODY & BONNET MATERIAL SPRING MATERIAL --------M/S. TYCO SANMAR LIMITED. CONVENTIONAL (FULL NOZZLE) SA351 GR. CF8M SA479 TP316 OPEN PLAIN SA216 GR. WCB CHROME STEEL
UNIT
SPECIFICATION
OPERATING DATA:
QUANTITY TAG NO. MODEL NO. MEDIUM SET PRESSURE TEMPERATURE REQD. RELIEVING CAPACITY
ACTUAL RELIEVING CAPACITY
DEAERATOR
NOS. ---Kscg C Kg/hr Kg/hr % % --MM --1 PSV-0001 JOS-H-E-15-C-IBR SATURATED STEAM 5.1 158.72 13730 23224 5.0 5.0 IBR ASME SEC-VIII 150 / 200 Q FLANGED, ASME B16.5, 150# RF
CBD TANK
1 PSV-0004 JOS-H-E-25-C-IBR-SPL SATURATED STEAM 8 174.5 1100 1204 5.0 5.0 IBR ASME SEC-VIII 25 / 50 G1 FLANGED, ASME B16.5, 300# RF
OVER PRESSURE BLOW DOWN SIZING CODE CODE VALVE INLET / OUTLET SIZE ORIFICE END CONNECTION INLET
--
SUPPLIERS ADDRESS:
M/s. TYCO SANMAR LIMITED, NO. 9, CATHEDRAL ROAD, CHENNAI - 600 086.
DATA SHEET
UNIT
SPECIFICATION
M/S. FISHER SANMAR LIMITED. 2X2 FCV-1101A & FCV-1101B (BG059) FCV-2101A & FCV-2101B (BG060) 3 HPT BODY GLOBE ANSI CLASS 900 BUTTWELD SCHD. 80 (OD 114.3 X 8.56 MM) SINGLE PORT DOWN 201A CAGE CLASS IV 2 7/8 NIT 50 0.5 EQUAL PERCENTAGE PLAIN SINGLE GRAPHITE PROVIDED WCC STEEL PLUG - 416 SST HD SEAT - 416 SST HD CAGE - 17 - 4 PH H1075
MATERIAL OF CONSTRUCTION
BODY TRIM
ACTUATOR
ACTUATOR TYPE SERIES / SIZE TRAVEL BENCH SET PUSH DOWN TO SUPPLY TO ACTUATOR FAILS VALVE HAND WHEEL ---PSI (g) --PSI (g) --SPRING DIAPHRAGM 667 / 45 1 11 29 CLOSE AIR 6 30 / 0 33 STAYPUT SIDE MOUNTED
DATA SHEET
UNIT
SPECIFICATION
OPERATING PARAMETERS
FLUID FLUID TEMPERATURE FLOW RATE INLET PRESSURE (P1) OUTLET PRESSURE (P2) DIFFERENTIAL PRESSURE (P) (P1-P2) SHUT OFF PRESSURE SPECIFIC GRAVITY (G) Kscg ---C Kg/hr Kscg Kscg Ksc
NOR.
MAX.
MIN.
DESIGN
FEED WATER 200 80000 113.5 97.68 17.82 200 96000 109.5 106.05 3.00 200 24000 127.32 95.26 32.05 200 96000 127.32 124.32 3.00
132.0 0.8650
132.0 0.8650
132.0 0.8650
132.0 0.8650
SUPPLIERS ADDRESS:
M/s. FISHER SANMAR LIMITED, 9, CATHEDRAL ROAD, CHENNAI - 600 086.
DATA SHEET
UNIT
SPECIFICATION
MATERIAL OF CONSTRUCTION
BODY TRIM
ACTUATOR
ACTUATOR TYPE SERIES / SIZE TRAVEL BENCH SET PUSH DOWN TO SUPPLY TO ACTUATOR FAILS VALVE HAND WHEEL ---PSI (g) --PSI (g) --SPRING DIAPHRAGM 657 / 40 3/4 6 14 CLOSE AIR 6 30 / 0 33 STAYPUT SIDE MOUNTED
DATA SHEET
UNIT
SPECIFICATION
OPERATING PARAMETERS
FLUID FLUID TEMPERATURE FLOW RATE INLET PRESSURE (P1) OUTLET PRESSURE (P2) DIFFERENTIAL PRESSURE (P) (P1-P2) SHUT OFF PRESSURE SPECIFIC GRAVITY (G) Kscg ---C Kg/hr Kscg Kscg Ksc
NOR.
MAX.
MIN.
DESIGN
FEED WATER 200 24000 128.82 96.89 31.93 200 28800 127.82 124.82 3.00 200 7200 128.17 96.87 31.30 200 28800 128.82 125.82 3.00
132.0 0.8650
132.0 0.8650
132.0 0.8650
132.0 0.8650
SUPPLIERS ADDRESS:
M/s. FISHER SANMAR LIMITED, 9, CATHEDRAL ROAD, CHENNAI - 600 086.
DATA SHEET
UNIT
SPECIFICATION
MATERIAL OF CONSTRUCTION
BODY TRIM
ACTUATOR
ACTUATOR TYPE SERIES / SIZE TRAVEL BENCH SET PUSH DOWN TO SUPPLY TO ACTUATOR FAILS VALVE HAND WHEEL ---PSI (g) --PSI (g) --SPRING DIAPHRAGM 667 / 40 3/4 15 27 CLOSE AIR 6 30 / 0 33 CLOSE SIDE MOUNTED
DATA SHEET
UNIT
SPECIFICATION
OPERATING PARAMETERS
FLUID FLUID TEMPERATURE FLOW RATE INLET PRESSURE (P1) OUTLET PRESSURE (P2) DIFFERENTIAL PRESSURE (P) (P1-P2) SHUT OFF PRESSURE SPECIFIC GRAVITY (G) Kscg ---C Kg/hr Kscg Kscg Ksc
NOR.
MAX.
MIN.
DESIGN
FEED WATER 200 2118.00 115.00 91.39 23.61 200 2541.60 128.82 125.82 3.00 200 635.40 110.55 91.40 19.15 200 2541.00 128.82 125.82 3.00
132.0 0.8650
132.0 0.8650
132.0 0.8650
132.0 0.8650
SUPPLIERS ADDRESS:
M/s. FISHER SANMAR LIMITED, 9, CATHEDRAL ROAD, CHENNAI - 600 086.
DATA SHEET
UNIT
SPECIFICATION
MATERIAL OF CONSTRUCTION
BODY TRIM
ACTUATOR
ACTUATOR TYPE SERIES / SIZE TRAVEL BENCH SET PUSH DOWN TO SUPPLY TO ACTUATOR FAILS VALVE HAND WHEEL ---PSI (g) --PSI (g) --SPRING & DIAPHRAGM 667 / 34 3/4 18 30 CLOSE AIR 6 30 / 0 33 STAYPUT SIDE MOUNTED
DATA SHEET
UNIT
SPECIFICATION
OPERATING PARAMETERS
FLUID FLUID TEMPERATURE FLOW RATE INLET PRESSURE (P1) OUTLET PRESSURE (P2) DIFFERENTIAL PRESSURE (P) (P1-P2) SHUT OFF PRESSURE SPECIFIC GRAVITY (G) Kscg ---C Kg/hr Kscg Kscg Ksc
NOR.
MAX.
MIN.
DESIGN
SUPERHEATED STEAM 330 3000 96.0 21.0 75.0 330 3500 96.0 21.0 75.0 330 1000 96.0 21.0 75.0 330 3500 96.0 21.0 75.0
104.0 0.828
104.0 0.828
104.0 0.828
104.0 0.828
SUPPLIERS ADDRESS:
M/s. FISHER SANMAR LIMITED, 9, CATHEDRAL ROAD, CHENNAI - 600 086.
(BOILER BG059)
DATA SHEET
UNIT
SPECIFICATION
MATERIAL OF CONSTRUCTION
BODY TRIM
ACTUATOR
ACTUATOR TYPE SERIES / SIZE TRAVEL BENCH SET PUSH DOWN TO SUPPLY TO ACTUATOR FAILS VALVE HAND WHEEL ---PSI (g) --PSI (g) --SPRING & DIAPHRAGM 667 / 34 3/4 18 30 CLOSE AIR 6 30 / 0 33 STAYPUT SIDE MOUNTED
(BOILER BG059)
DATA SHEET
UNIT
SPECIFICATION
OPERATING PARAMETERS
FLUID FLUID TEMPERATURE FLOW RATE INLET PRESSURE (P1) OUTLET PRESSURE (P2) DIFFERENTIAL PRESSURE (P) (P1-P2) SHUT OFF PRESSURE SPECIFIC GRAVITY (G) Kscg ---C Kg/hr Kscg Kscg Ksc
NOR.
MAX.
MIN.
DESIGN
FEED WATER 160 600 6.0 3.0 3.0 160 1000 6.0 3.0 3.0 160 200 6.0 3.0 3.0 160 1000 6.0 3.0 3.0
10.0 0.909
10.0 0.909
10.0 0.909
10.0 0.909
SUPPLIERS ADDRESS:
M/s. FISHER SANMAR LIMITED, 9, CATHEDRAL ROAD, CHENNAI - 600 086.
DATA SHEET
SPECIFICATION
DATA SHEET
SPECIFICATION
QTY. (Nos)
TAG NO.
SCB-1301 (BG059) SCB-2301 (BG060)
SERVICE
FD HEADER OUTLET
BLOCK QTY.
24 1X2
02
PA HEADER OUTLET
24
1X2
03
SA LINE
12
1X2
04
12
1X2
05
24
1X2
SUPPLIERS ADDRESS:
M/s. ROTEX AUTOMATION LIMITED, 987/11, G.I.D.C., MAKARPURA, N.H.8, OPP. S.T. DEPT., VADODARA - 390 010.
DATA SHEET
SPECIFICATION
DATA SHEET
SPECIFICATION
SUPPLIERS ADDRESS:
M/S ELO-MATIC (INDIA) PVT.LTD. NO. 5, MAHALINGA CHETTY II CROSS STREET, MAHALINGAPURAM, CHENNAI - 600 034. NUNGAMPAKKAM,
(BOILER BG059 )
DATA SHEET
SPECIFICATION
M/S. ELO-MATIC (INDIA) PVT.LTD. 1 NO. SOV0001 FOR DEAERATOR OVER FLOW FEED WATER 160C 7.0 Kg/cm (g) 10.0 Kg/cm (g) 174 m/hr 0.91 60.8 540
(BOILER BG059 )
DATA SHEET
SPECIFICATION
SUPPLIERS ADDRESS:
M/S ELO-MATIC (INDIA) PVT.LTD. NO. 5, MAHALINGA CHETTY II CROSS STREET, MAHALINGAPURAM, CHENNAI - 600 034. NUNGAMPAKKAM,
DATA SHEET
MOTORISED VALVES
DESCRIPTION GENERAL DATA:
MAKE QUANTITY APPLICATION MEDIUM TAG NO. TYPE SIZE END CONNECTION RATING BODY MATERIAL TRIM PACKING AND GASKET LEAKGE CLASS OPERATION ALLOWABLE DELTA PRESSURE EDGE PREPARATION ELECTRICAL ACTUATOR MAKE MODEL ACTUATOR WIRING DIAGRAM OPEN/CLOSE TIME SPEED TORQUE RANGE DUTY DUTY CYCLE ENCLOSURE AVERAGE/NOMINAL OUTPUT RATED VOLTAGE RATED FREQUENCY NUMBER OF PHASE ADMISABLE COMBIND VARIATION % KW min. SEC RPM Kg-m ROTORK K600F14A 8205+CLI 21 72 24 TO 62 NON-INCHING S2-15 IP 68 2.5 415 V 10 % 50 Hz 5 % 3 10 ROTARK K30F10A 8205+CLI 10 18 1.3-3.4 NON-INCHING S2-15 IP 68 0.09 415 V 10 % 50 Hz 5 % 3 10 BAR # NB -Nos M/S. KSB PUMPS LIMITED. 1X2 MAIN STEAM STOP VALVE WITH INTEGRAL BYPASS SUPER HEATED STEAM MOV1202A & B (BG059) / MOV2202A & B (BG060) FOR MAIN VALVE GATE 200 BUTTWELD 1500 SA217 WC9 5 GRAPHITED CLASS-IV ELECTRICAL ACTUATOR 159 200NB SCH 120 258 NIL FOR BYPASS VALVE GATE 25 SOCKET WELD 1500 SA182 F22 5 GRAPHITED CLASS-IV
UNIT
SPECIFICATION
DATA SHEET
MOTORISED VALVES
DESCRIPTION
NORMAL CURRENT OLR SET VALUE STARTING CURRENT FULL LOAD SPEED INSULATION CLASS POWER FACTOR (AVERAGE LOAD) AVERAGE LOAD EFFICIENCY ADMISABLE AMBIANT TEMPERATURE TEMPERATURE RISE OVER AMBIENT TEMP. TYPE OF STARTER CABLE ENTRY GEAR BOX LUBRICATION POSITION LIMIT SWITCH TORQUE SWITCHES RATING OF SWITCHES POSITION TRANSMITTER ON-OFF DUTY POSITION TRANSMITTER INCHING DUTY SPACE HEATER THERMOSTAT INTERNAL WIRING CONTROL CIRCUIT DIAGRAM MOTOR SUITABLE FOR ON-OFF/ INCHING MOTOR TYPE AND REFERENCE STANDARD SQURREL CAGE INDUCTION, IS 325 FOR ON-OFF 60 STRATS PER HOUR % DEG. C DEG. C
UNIT
A A A RPM
SPECIFICATION
9.0 12 60 2880 F 0.59 65.00 MINUS 30 TO 70 80 DOL 0.5 0.6 3 2880 F 0.75 33.00 MINUS 30 TO 70 80 DOL 1" BRITISH METRIC (4 NUMBERS) ALPHA SP 68 OR SAE EP80 2 NO + 2 NC (4 NUMBERS) 2 NO + 2 NC (2 NUMBERS) 110V/240V, AC 5A, 0.5A 220V DC NOT REQUIRED NOT REQUIRED 1 NUMBER, 110/240V, AC, 1, 50 Hz 2 NUMBERS ONE EACH WINDING PVC 1.5 mm WITHOUT INTEGRAL STARTER : WD8205
SUPPLIERS ADDRESS:
M/s. KSB PUMPS LIMITED, GUINDY HOUSE, 2ND FLOOR, 95, ANNA SALAI, GUINDY, CHENNAI - 600 032.
(BOILER BG059)
DATA SHEET
MOTORISED VALVES
DESCRIPTION GENERAL DATA:
MAKE QUANTITY APPLICATION MEDIUM TAG NO. TYPE SIZE END CONNECTION RATING BODY MATERIAL TRIM PACKING AND GASKET LEAKGE CLASS OPERATION ALLOWABLE DELTA PRESSURE EDGE PREPARATION ELECTRICAL ACTUATOR MAKE MODEL ACTUATOR WIRING DIAGRAM OPEN/CLOSE TIME SPEED TORQUE RANGE DUTY DUTY CYCLE ENCLOSURE AVERAGE/NOMINAL OUTPUT RATED VOLTAGE RATED FREQUENCY NUMBER OF PHASE ADMISABLE COMBIND VARIATION % KW min. SEC RPM Kg-m ROTORK K300F14A 8205+CLI 18 72 6 TO 15.4 NON-INCHING S2-15 IP 68 1.2 415 V 10 % 50 Hz 5 % 3 10 BAR # NB -Nos M/S. KSB PUMPS LIMITED. 5 ISO. OF BOILER I & II FEED PUMP DELIVERY FEED WATER / STEAM MOV0101 TO MOV0103, MOV0107 & MOV0108 GATE 150 BUTTWELD 900 SA216 WCB 5 GRAPHITED CLASS-IV ELECTRICAL ACTUATOR 155 155 NB. SCH. 80
UNIT
SPECIFICATION
(BOILER BG059)
DATA SHEET
MOTORISED VALVES
DESCRIPTION
NORMAL CURRENT OLR SET VALUE STARTING CURRENT FULL LOAD SPEED INSULATION CLASS POWER FACTOR (AVERAGE LOAD) AVERAGE LOAD EFFICIENCY ADMISABLE AMBIANT TEMPERATURE TEMPERATURE RISE OVER AMBIENT TEMP. TYPE OF STARTER CABLE ENTRY GEAR BOX LUBRICATION POSITION LIMIT SWITCH TORQUE SWITCHES RATING OF SWITCHES POSITION TRANSMITTER ON-OFF DUTY POSITION TRANSMITTER INCHING DUTY SPACE HEATER THERMOSTAT INTERNAL WIRING CONTROL CIRCUIT DIAGRAM MOTOR SUITABLE FOR ON-OFF/ INCHING MOTOR TYPE AND REFERENCE STANDARD SQURREL CAGE INDUCTION, IS 325 1 NUMBER, 110 / 240 V AC, 1, 50 Hz 2 NUMBERS ONE EACH WINDING PVC 1.5 mm WITHOUT INTEGRAL STARTER : WD8205 FOR ON-OFF 60 STRATS PER HOUR NOT REQUIRED DOL 1" BRITISH METRIC (4 NUMBERS) ALPHA SP 68 OR SAE EP80 2 NO + 2 NC (4 NUMBERS) 2 NO + 2 NC (2 NUMBERS) 110 V / 240 V, AC 5A, 0.5A 220V DC NOT REQUIRED % DEG.C DEG.C
UNIT
A A A RPM
SPECIFICATION
3.1 4.5 23 2880 F 0.70 77.0 MINUS 30 TO 70 80
SUPPLIERS ADDRESS:
M/s. KSB PUMPS LIMITED, GUINDY HOUSE, 2ND FLOOR, 95, ANNA SALAI, GUINDY, CHENNAI - 600 032.
(BOILER BG059)
DATA SHEET
MOTORISED VALVES
DESCRIPTION GENERAL DATA:
MAKE QUANTITY APPLICATION MEDIUM TAG NO. TYPE SIZE END CONNECTION RATING BODY MATERIAL TRIM PACKING AND GASKET LEAKGE CLASS OPERATION ALLOWABLE DELTA PRESSURE EDGE PREPARATION ELECTRICAL ACTUATOR MAKE MODEL ACTUATOR WIRING DIAGRAM OPEN/CLOSE TIME SPEED TORQUE RANGE DUTY DUTY CYCLE ENCLOSURE AVERAGE/NOMINAL OUTPUT RATED VOLTAGE RATED FREQUENCY NUMBER OF PHASE ADMISABLE COMBIND VARIATION % KW min. SEC RPM Kg-m ROTORK K600F14A 8205+CLI 26 72 24 TO 62 NON-INCHING S2-15 IP 68 2.5 415 V 10 % 50 Hz 5 % 3 10 BAR # NB -Nos M/S. KSB PUMPS LIMITED. 3 NOS ISOLATION VALVE FOR OPEN AND CLOSE FEED WATER / STEAM MOV0104 TO MOV0106 GATE 200 BUTTWELD 900 SA 216 WCB 5 GRAPHITED CLASS-IV ELECTRICAL ACTUATOR 155 200 NB SCH. 80
UNIT
SPECIFICATION
(BOILER BG059)
DATA SHEET
MOTORISED VALVES
DESCRIPTION
NORMAL CURRENT OLR SET VALUE STARTING CURRENT FULL LOAD SPEED INSULATION CLASS POWER FACTOR (AVERAGE LOAD) AVERAGE LOAD EFFICIENCY ADMISABLE AMBIANT TEMPERATURE TEMPERATURE RISE OVER AMBIENT TEMP. TYPE OF STARTER CABLE ENTRY GEAR BOX LUBRICATION POSITION LIMIT SWITCH TORQUE SWITCHES RATING OF SWITCHES POSITION TRANSMITTER ON-OFF DUTY POSITION TRANSMITTER INCHING DUTY SPACE HEATER THERMOSTAT INTERNAL WIRING CONTROL CIRCUIT DIAGRAM MOTOR SUITABLE FOR ON-OFF/ INCHING MOTOR TYPE AND REFERENCE STANDARD SQURREL CAGE INDUCTION, IS 325 1 NUMBER, 110 / 240 V AC, 1, 50 Hz 2 NUMBERS ONE EACH WINDING PVC 1.5 mm WITHOUT INTEGRAL STARTER : WD8205 FOR ON-OFF 60 STRATS PER HOUR NOT REQUIRED DOL 1" BRITISH METRIC (4 NUMBERS) ALPHA SP 68 OR SAE EP80 2 NO + 2 NC (4 NUMBERS) 2 NO + 2 NC (2 NUMBERS) 110 V / 240 V, AC 5A, 0.5A 220V DC NOT REQUIRED % DEG.C DEG.C
UNIT
A A A RPM
SPECIFICATION
9 12 60 2880 F 0.59 65.0 MINUS 30 TO 70 80
SUPPLIERS ADDRESS:
M/s. KSB PUMPS LIMITED, GUINDY HOUSE, 2ND FLOOR, 95, ANNA SALAI, GUINDY, CHENNAI - 600 032.
(BOILER BG059)
DATA SHEET
MOTORISED VALVES
DESCRIPTION GENERAL DATA:
MAKE QUANTITY APPLICATION MEDIUM TAG NO. TYPE SIZE END CONNECTION RATING BODY MATERIAL TRIM PACKING AND GASKET LEAKGE CLASS OPERATION ALLOWABLE DELTA PRESSURE EDGE PREPARATION ELECTRICAL ACTUATOR MAKE MODEL ACTUATOR WIRING DIAGRAM OPEN/CLOSE TIME SPEED TORQUE RANGE DUTY DUTY CYCLE ENCLOSURE AVERAGE/NOMINAL OUTPUT RATED VOLTAGE RATED FREQUENCY NUMBER OF PHASE ADMISABLE COMBIND VARIATION % KW min. SEC RPM Kg-m ROTORK K600F14A 8205+CLI 26 72 24 TO 62 NON-INCHING S2-15 IP 68 2.5 415 V 10 % 50 Hz 5 % 3 10 BAR # NB -Nos M/S. KSB PUMPS LIMITED. 1 NO ISOLATION VALVE FOR OPEN AND CLOSE FEED WATER / STEAM MOV0201 GATE 150 BUTTWELD 1500 SA 217 WC9 5 GRAPHITED CLASS-IV ELECTRICAL ACTUATOR 155 200 NB SCH. 80
UNIT
SPECIFICATION
(BOILER BG059)
DATA SHEET
MOTORISED VALVES
DESCRIPTION
NORMAL CURRENT OLR SET VALUE STARTING CURRENT FULL LOAD SPEED INSULATION CLASS POWER FACTOR (AVERAGE LOAD) AVERAGE LOAD EFFICIENCY ADMISABLE AMBIANT TEMPERATURE TEMPERATURE RISE OVER AMBIENT TEMP. TYPE OF STARTER CABLE ENTRY GEAR BOX LUBRICATION POSITION LIMIT SWITCH TORQUE SWITCHES RATING OF SWITCHES POSITION TRANSMITTER ON-OFF DUTY POSITION TRANSMITTER INCHING DUTY SPACE HEATER THERMOSTAT INTERNAL WIRING CONTROL CIRCUIT DIAGRAM MOTOR SUITABLE FOR ON-OFF/ INCHING MOTOR TYPE AND REFERENCE STANDARD SQURREL CAGE INDUCTION, IS 325 1 NUMBER, 110 / 240 V AC, 1, 50 Hz 2 NUMBERS ONE EACH WINDING PVC 1.5 mm WITHOUT INTEGRAL STARTER : WD8205 FOR ON-OFF 60 STRATS PER HOUR NOT REQUIRED DOL 1" BRITISH METRIC (4 NUMBERS) ALPHA SP 68 OR SAE EP80 2 NO + 2 NC (4 NUMBERS) 2 NO + 2 NC (2 NUMBERS) 110 V / 240 V, AC 5A, 0.5A 220V DC NOT REQUIRED % DEG.C DEG.C
UNIT
A A A RPM
SPECIFICATION
9 12 60 2880 F 0.59 65.0 MINUS 30 TO 70 80
SUPPLIERS ADDRESS:
M/s. KSB PUMPS LIMITED, GUINDY HOUSE, 2ND FLOOR, 95, ANNA SALAI, GUINDY, CHENNAI - 600 032.
DATA SHEET
SPECIFICATION
DATA SHEET
SPECIFICATION
65.00% MINUS 30 TO 70 DEG.C 70 DEG.C DOL ONE NUMBER 3/4" CABLE GLAND SUTABLE FOR 3C X 6.0 mm CABLE OD, 14+2 mm OR 17+ 2 mm. THREE NUMBER 1" BRITISH METRIC CABLE GLAND SUTABLE FOR 19C X 1.5 mm CABLE OD, NOT EXCEEING 23 mm ALPHA SP 68 OR SAE EP80 2 NO + 2 NC (4 NUMBERS) 2 NO + 2 NC (2 NUMBERS) 110 V / 240 V AC 5A, 0.5A 220 V DC 4-20 mA, 2 WIRE, 24V DC ONE NUMBER 1 PHASE, 50 Hz, 10 WATTS SUITABLE FOR 110/240V, AC INCASE OF ACTUATOR 3 NUMBERS ONE EACH WINDING PVC 1.5 mm WITHOUT IS WITH EPT : BH 9235G
SUPPLIERS ADDRESS:
M/S. BHARAT HEAVY ELECTRICALS LIMITED. COMMERCIAL DEPARTMENT, VALVE DEVISION, TRICHIRAPPALLI 620 014.
DATA SHEET
SPECIFICATION
DATA SHEET
CBD LINE
MINUS 30 TO 70C 70C DOL
IBD LINE
ONE NUMBER 3/4" CABLE GLAND SUTABLE FOR 3C X 6.0 mm CABLE OD, 14+2 mm OR 17+ 2 mm.
CABLE GLAND SIZE - CONTROL CABLE(DOUBLE COMPRESSION TYPE) GEAR BOX LUBRICATION POSITION LIMIT SWITCH TORQUE SWITCHES RATING OF SWITCHES POSITION TRANSMITTER INCHING DUTY SPACE HEATER THERMOSTAT INTERNAL WIRING CONTROL CIRCUIT DIAGRAM MOTOR SUITABLE FOR ON-OFF/ INCHING MOTOR TYPE AND REFERENCE STANDARD OLR SET VALUE
THREE NUMBER 1" BRITISH METRIC CABLE GLAND SUTABLE FOR 19C X 1.5 mm CABLE OD, NOT EXCEEING 23 mm ALPHA SP 68 OR SAE EP80 2 NO + 2 NC (4 NUMBERS) 2 NO + 2 NC (2 NUMBERS) 110V/240V, AC 5A, 0.5A 220V DC 4-20 mA, 2 WIRE, 24V DC ONE NUMBER 1 PHASE, 50 Hz, 10 WATTS SUITABLE FOR 110/240V, AC FOR ACTUATOR WITHOUT IS 3 NUMBERS ONE EACH WINDING PVC 1.5 mm WITHOUT IS WITH EPT : BH 9235G FOR ON-OFF 60 STRATS PER HOUR FOR INCHING 150 STARTS PER HOUR SQURREL CAGE INDUCTION, IS 325
1A
SUPPLIERS ADDRESS:
M/S. BHARAT HEAVY ELECTRICALS LIMITED. COMMERCIAL DEPARTMENT, VALVE DEVISION, TRICHIRAPPALLI 620 014.
(BOILER BG059)
DATA SHEET
SPECIFICATION
M/S. FAINGER ENGG. 1 NO. VRV001 DEAERATOR GLOBE - SELF ACTUATED VRV-40-F-VS6 VACUUM RELIEF IN DEAERATOR STORAGE TANK 15 Ncu.m/hr. (-)45 TO (-) 55 mmwc 40 NB AIR ATM -50 mmwc -50 mmwc 1 CLASS V CARBON STEEL SS 316 TEFLON CARBON STEEL SPRING STEEL STAINLESS STEEL CARBON STEEL 150# FLANGED, ANSI B16.5
SUPPLIERS ADDRESS:
M/S. FAINGER ENGINEERING 6 & 21, APURVA INDL. ESTATE, MAKWANA ROAD, MAROL, ANDHERI (EAST), MUMBAI 400 059.
fainger engineering
An ISO 9001:2000 Company
OPERATION, INSTALLATION VACUUM VALVES Operation: These valves are designed to provide emergency Purging of Air/ Gases from Storage tanks/ Low pressure Vessels. The Pallet is Dead weight or Spring Loaded depending on the Vacuum Settings specified. The valves are factory set to relieve at specified Vacuums. When the level of liquid reduces in the tank, Vacuum is created which is broken by the opening of vacuum port pallet allowing air to enter into the tank. When the desired vacuum set is reached, the Pallet closes the opening and flow of air inside is cut-off. Installation: Remove any protective cover provided on the Process Connection. Mount the Valve to the appropriate inlet and/or outlet flange using gaskets compatible with service conditions. Maintenance: 1. Remove the Cover and Inspect the gasket on the covers. Replace if deteriorated or damaged. 2. Remove any loose dirt or foreign material from the housing interior and exterior. Check inside the stem guide hole of the covers and remove any dirt or accumulation of foreign material from these holes. 3. Withdraw vacuum pallet assemblies and set aside for inspection. Note: identify any weights on the vacuum pallet assemblies for later reinstallation. 4. Inspect the screens that protect the vacuum ports. Clean or replace as necessary. 5. Inspect and clean the machined seating surfaces in the vent housings with a suitable cleaning fluid. Seats should be free of nicks, mars or accumulations of foreign material. Caution: Do not use a file or other sharp tool to clean seating surface. Use Fine Lapping Paste and Glass to Lap the Seating area. Use clean soft cloth for wiping/cleaning lapped surface. & MAINTENANCE MANUAL FOR
fainger engineering
An ISO 9001:2000 Company
6. Inspect the pallet assemblies. If pallets are deteriorated or bent, they must be replaced. 7. Inspect the diaphragm (if provided) material in the pallet assemblies. The diaphragms must be clean, flat and smooth. If the diaphragm material is deteriorated, it must be replaced. Make sure that all nuts and screws on the pallet assemblies are tightened securely. 8. Reinstall vacuum pallet assemblies into their respective openings. Setting weights (if required) should be reinstalled by engaging the hole in the weight on the appropriate pallet assembly stem. 9. Replace the covers and screens. Note: Make sure that the pallet assembly stem positively engages the stem guide hole in the cover. Each pallet assembly must be free to move upwards, with the pallet stem traveling into the stem guide. 10. Replace nuts and tighten to secure covers in position.
DATA SHEET
SPECIFICATION
DATA SHEET
SPECIFICATION
SUPPLIERS ADDRESS:
M/s. INSTRUMENTATION LIMITED, KANJIKODE WEST, PALGHAT - 678 623. KERALA STATE.
DATA SHEET
SPECIFICATION
TAG NO.
MODEL NO. DUTY TYPE PISTON AND ROD CONN. MOUNTING BORE STROKE ACCESSORIES DESIGN CYLINDER TUBE CUSHIONING OPERATING MEDIUM OPERATING PRESSURE OEPRATING TEMPERATURE MIN. OPERATING PRESSURE MAXIMUM SPEED QUALITY OF COMPRESSED AIR COMPRESSED AIR INLET TUBING SIZE COMPRESSED AIR INLET END CONNECTION
ON-OFF (STANDARD) DOUBLE ACTING FORK WITH PIN AND NUT REAR HINGE WITH PIN AND COUNTER HINGE 3 INCH 12 INCH 3 INCH 8 INCH TWO REED SWITCHES AND LEATHER BELLOWS ACCORDING TO ISO 6431 & VDMA 24562 EXTRUDED ALUMINIUM PROFILE AT BOTH ENDS & ADJUSTABLE COMPRESSED AIR 01-10. BAR MINUS 20 TO 70 DEG.C 0.2 BAR 1.5 m/sec FILTERED TO MIN. 50m., DEW POINT 3-5 DEG.C WITH OIL MIST LUBRICATION 1/4" OD SS/COPPER TUBING
DATA SHEET
SPECIFICATION
SUPPLIERS ADDRESS:
M/s. ROTEX MANUFACTURERS & ENGINEERS PVT. LTD, MANPADA ROAD, NEAR BHOPAR VILLAGE, DOMBIVLI (EAST), THANE - 421 204.
DATA SHEET
SPECIFICATION
DATA SHEET
SPECIFICATION
SUPPLIERS ADDRESS:
M/s. ROTEX MANUFACTURERS & ENGINEERS PVT. LTD, MANPADA ROAD, NEAR BHOPAR VILLAGE, DOMBIVLI (EAST), THANE - 421 204.