0% found this document useful (0 votes)
71 views12 pages

Group: High Temperature Gas-Cooled Reactor (HTGR) by Micro Simulation Technology

LOGO Groupe E High Temperature Gas-Cooled Reactor (HTGR) by Micro Simulation Technology. Four cases selected for PCTRAN HTR-10 verification from the following paper. Transient key plots are follows: Case I: He Circulator Trip ATWS Case I: Rod Withdrawal from 30% power.

Uploaded by

Singh 10
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
71 views12 pages

Group: High Temperature Gas-Cooled Reactor (HTGR) by Micro Simulation Technology

LOGO Groupe E High Temperature Gas-Cooled Reactor (HTGR) by Micro Simulation Technology. Four cases selected for PCTRAN HTR-10 verification from the following paper. Transient key plots are follows: Case I: He Circulator Trip ATWS Case I: Rod Withdrawal from 30% power.

Uploaded by

Singh 10
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 12

LOGO

Group

E
High Temperature Gas-Cooled Reactor (HTGR) by Micro Simulation Technology.
Zaki Ahmed Abbasi Charanpreet Ramandeep

Contents

1
2 3 4

Introduction

Simulation

Cases

Click to add Title

Transient Verification Runs


Four Cases were selected for PCTRAN HTR-10 verification from the following paper.
Commissioning and Operation Experience and safety Experiments on HTR-10 3rd International Topical Meeting on High Temperature Reactor Technology. October 1-4, 2006,Johannesburg, South Africa.

Transient Verification Runs


Model is brought to Critical. Maintained near 100%Power. Operating Variables are: Toutlet = 703.7C Tinlet = 252.1 C He Circulation flow = 4.28 kg/sec Core Power = 10 MW He Pressure = 2.96 MPa

Design Parameters

Text

Text

Case I: He Circulator Trip ATWS Test


Reactor Started at 100% power steady state. Switch from P to S. Rod Speed set to zero to prevent its movement. The He Circulator is tripped without incurring a reactor scram. The transient key plots are follows:

Case I: He Circulator Trip ATWS

Case I: He Circulator Trip ATWS

Case I: He Circulator Trip ATWS

More Cases
A steady state at 30% power is created for benchmark of three operational transients.
Rod Withdrawal from 30% power. Varying Helium Circulation Rate. Feed water Alterations.

LOGO