The Effect of Sensor Placement on Measured Distal Tibial Accelerations During Running

J Appl Biomech. 2023 Apr 27;39(3):199-203. doi: 10.1123/jab.2022-0249. Print 2023 Jun 1.

Abstract

Inertial measurement units (IMUs) attached to the distal tibia are a validated method of measuring lower-extremity impact accelerations, called tibial accelerations (TAs), in runners. However, no studies have investigated the effects of small errors in IMU placement, which would be expected in real-world, autonomous use of IMUs. The purpose of this study was to evaluate the effect of a small proximal shift in IMU location on mean TAs and relationships between TAs and ground reaction force loading rates. IMUs were strapped to 18 injury-free runners at a specified standard location (∼1 cm proximal to medial malleolus) and 2 cm proximal to the standard location. TAs and ground reaction forces were measured while participants ran at self-selected and 10% slower/faster speeds. Mean TA was lower at the standard versus proximal IMU location in the faster running condition (P = .026), but similar in the slower (P = .643) and self-selected conditions (P = .654). Mean TAs measured at the standard IMU explained more variation in ground reaction force loading rates (r2 = .79-.90; P < .001) compared with those measured at the proximal IMU (r2 = .65-.72; P < .001). These results suggest that careful attention should be given to IMU placement when measuring TAs during running.

Keywords: IMU; accelerometer; gait mechanics; tibial shock.

MeSH terms

  • Acceleration*
  • Biomechanical Phenomena
  • Foot
  • Humans
  • Lower Extremity
  • Tibia*