Sala Descrição Model RTC ATC RTH ATH Air Flow Sound Dimension Weight Static Pressure Power Supply
kW kW kW kW m^3/h dBA mm kg Pa
ATEN Indoor 4TVX0030B1000AA 9 8.30 10 9.44 1200 45 1280*206*66 34.5 N/A 208-
D 04 Unit 1 2 0 230V~60Hz
SERV Indoor 4TVW0009B1000AA 2.8 2.57 3.2 2.99 557 35 915*290*210 12 N/A 208-
IDOR Unit 5 6 230V~60Hz
CAIX Indoor 4TVW0015B1000AA 4.5 4.13 5 4.67 842 40 1070*315*21 16 N/A 208-
AS Unit 6 4 0 230V~60Hz
TESO Indoor 4TVW0009B1000AA 2.8 2.57 3.2 2.98 557 35 915*290*210 12 N/A 208-
URA Unit 230V~60Hz
RIA
Outd Outdoor 4TVH0055BK000AA 19.1 17.7 21.4 20.2 6000 57 900*1327*32 102 N/A 380-415V
oor Unit 0 3N~60Hz
The information provided by the software is for informational purposes needs to be verified with the IOM manual and that any discrepancy between the software
and IOM should be communicated in writing for further verification.
RTC: Capacidade total de arrefecimento necessária
ATC: Capacidade total de arrefecimento disponível
RTH: Capacidade total de calefação necessária
ATH: Capacidade total de calefação disponível
3.3 Distribuidores de Tubo e Refrigerante
Pipe
Não Longitude Tubo Gás Tubulação Líquido
(1) 8.0m Ø22.2 Ø9.53
(2) 4.0m Ø19.1 Ø9.53
(3) 3.0m Ø15.9 Ø9.53
(4) 8.0m Ø12.7 Ø6.35
(5) 3.0m Ø19.1 Ø9.53
(6) 6.0m Ø12.7 Ø6.35
(7) 10.0m Ø12.7 Ø6.35
Distribuidor
Não Carga kW Modelo
(1) 19.1 TRDK112HP
(2) 10.1 TRDK056HP
(3) 7.3 TRDK056HP
3.4 Esboço
TVR 60Hz R410A
17.7 kW
4TVH0055BK000AA
2.57 kW
Ø12.7,Ø6.35 4TVW0009B1000AA
(7)10.0m TESOURARIA
2.575 kW
Ø12.7,Ø6.35 4TVW0009B1000AA
(4)8.0m SERVIDOR
8.301 kW
Ø15.9,Ø9.53 4TVX0030B1000AA
(3)3.0m ATEND 04
The piping size may be different with the actual situation because of the software's illustration limitation,please confirm
the piping size according to the installation manual before installation.
3.5 Controlador opcional
wire gauge 0.75 mm^2 up to 200m, for larger lengths use 1.1 mm^2
OU-1
PQE
ATEND 04
PQE
SERVIDOR
PQE
CAIXAS
PQE
TESOURARIA
4.AGRUPAR2
Sala Descrição Model RTC ATC RTH ATH Air Flow Sound Dimension Weight Static Pressure Power Supply
kW kW kW kW m^3/h dBA mm kg Pa
ATEN Indoor 4TVX0030B1000AA 9 8.67 10 9.54 1200 45 1670*244*68 34.5 N/A 208-
D 03 Unit 4 5 0 230V~60Hz
ATEN Indoor 4TVX0030B1000AA 9 8.67 10 9.54 1200 45 1670*244*68 34.5 N/A 208-
D 02 Unit 4 5 0 230V~60Hz
Outd Outdoor 4TVH0055BK000AA 18 17.4 20 19.1 6000 57 900*1327*32 102 N/A 380-415V
oor Unit 0 3N~60Hz
The information provided by the software is for informational purposes needs to be verified with the IOM manual and that any discrepancy between the software
and IOM should be communicated in writing for further verification.
RTC: Capacidade total de arrefecimento necessária
ATC: Capacidade total de arrefecimento disponível
RTH: Capacidade total de calefação necessária
ATH: Capacidade total de calefação disponível
4.3 Distribuidores de Tubo e Refrigerante
Pipe
Não Longitude Tubo Gás Tubulação Líquido
(1) 8.0m Ø22.2 Ø9.53
(2) 6.0m Ø15.9 Ø9.53
(3) 6.0m Ø15.9 Ø9.53
Distribuidor
Não Carga kW Modelo
(1) 18 TRDK112HP
4.4 Esboço
4TVH0055BK000AA
(1) 8.674 kW
Ø22.2,Ø9.53 Ø15.9,Ø9.53 4TVX0030B1000AA
(1)8.0m (2)6.0m ATEND 03
TRDK112HP
8.674 kW
Ø15.9,Ø9.53 4TVX0030B1000AA
(3)6.0m ATEND 02
The piping size may be different with the actual situation because
of the software's illustration limitation,please confirm the piping
size according to the installation manual before installation.
4.5 Controlador opcional
wire gauge 0.75 mm^2 up to 200m, for larger lengths use 1.1 mm^2
OU-1
PQE
ATEND 03
PQE
ATEND 02
5.AGRUPAR3
Sala Descrição Model RTC ATC RTH ATH Air Flow Sound Dimension Weight Static Pressure Power Supply
kW kW kW kW m^3/h dBA mm kg Pa
CAS Indoor 4TVX0030B1000AA 9 8.67 10 9.54 1200 45 1670*244*68 34.5 N/A 208-
H Unit 4 5 0 230V~60Hz
ATEN Indoor 4TVX0030B1000AA 9 8.67 10 9.54 1200 45 1670*244*68 34.5 N/A 208-
D 01 Unit 4 5 0 230V~60Hz
Outd Outdoor 4TVH0055BK000AA 18 17.4 20 19.1 6000 57 900*1327*32 102 N/A 380-415V
oor Unit 0 3N~60Hz
The information provided by the software is for informational purposes needs to be verified with the IOM manual and that any discrepancy between the software
and IOM should be communicated in writing for further verification.
RTC: Capacidade total de arrefecimento necessária
ATC: Capacidade total de arrefecimento disponível
RTH: Capacidade total de calefação necessária
ATH: Capacidade total de calefação disponível
5.3 Distribuidores de Tubo e Refrigerante
Pipe
Não Longitude Tubo Gás Tubulação Líquido
(1) 8.0m Ø22.2 Ø9.53
(2) 6.0m Ø15.9 Ø9.53
(3) 6.0m Ø15.9 Ø9.53
Distribuidor
Não Carga kW Modelo
(1) 18 TRDK112HP
5.4 Esboço
4TVH0055BK000AA
(1) 8.674 kW
Ø22.2,Ø9.53 Ø15.9,Ø9.53 4TVX0030B1000AA
(1)8.0m (2)6.0m CASH
TRDK112HP
8.674 kW
Ø15.9,Ø9.53 4TVX0030B1000AA
(3)6.0m ATEND 01
The piping size may be different with the actual situation because
of the software's illustration limitation,please confirm the piping
size according to the installation manual before installation.
5.5 Controlador opcional
wire gauge 0.75 mm^2 up to 200m, for larger lengths use 1.1 mm^2
OU-1
PQE
CASH
PQE
ATEND 01