6 - Comando Console
6 - Comando Console
6 - Comando Console
$ ppdelta 300 all spoippp01 fruni/130801 dlci/*** D ******* (SGO) COMANDOS PARA TESTE PELO TELNET ( SGO ) ******
TELNET 172.201.192.22 LOGIN:SPPAC PASWORD:SPPAC EX: TELNET SPOPDPP03 ENTER LOGIN: E011172 SENHA:MDM
6 - COMANDOS PARA FECHAR LOOP PELA TELNET/CONSOLE: para testes com tecnico GTD na tx ou no cliente local, usando o test set para emular frame
LOCK LP/**** E1/**** CH/**** SET LP/**** E1/**** CH/**** TEST TYPE EXTERNALLOOP,DURA 60 (quando fruni) SE O COMANDO DE CIMA DER ERRO SETAR ESSE: SET LP/**** E1/**** CH/**** TEST TYPE PAYLOADLOOP,DURA 60 (quando fratm) START LP/**** E1/**** CH/**** TEST STOP TEST UNLOCK LP/**** E1/**** CH/****
7 - COMANDOS PARA ENXERGAR LOOP PELA TELNET/CONSOLE: (quando cpcc 72, fechar loop na det ou se no cliente possuir modem gerenciavel acionar LDR/LDL)
LOCK LP/**** E1/**** CH/**** bloqueando a LP dentro do E1 SET LP/**** E1/**** CH/**** TEST TYPE MANU,DURA 60 ==> setando a porta, para o teste manual de 60 minutos START LP/**** E1/**** CH/**** TEST ===> inicia o teste D LP/**** E1/**** CH/**** TEST ==> visualiza a carga do teste ( ou seja visualiza o loop fechado na r.deterministica) STOP TEST LP/ E1/ CH/ TEST ==> pra o teste UNLOCK LP/**** E1/**** CH/**** ==> desbloqueia a porta
SunOS 5.8 login: sppac Password: sppac Last login: Mon Nov 6 11:14:59 from 10.11.4.195 Sun Microsystems Inc. SunOS 5.8 Generic Patch October 2001 You have new mail. CGER > cd /opt/M*NMS/bin CGER > setenv DISPLAY 10.11.4.195:0.0 ( obs:sempre colocar o ip da maquina
que voce esta utilizando ,INICIAR ,EXECULTAR ,DIGITAR :CMD ipconfig VERIF IP ) CGER > nmstool & [1] 270 CGER >
- (OCOOSPP03 FRATM/30103 DL/16) => (SPOPIPP03 ATMIF/131 VCC/0.56) ***COMANDO PARA SABER ENDEREO DO ATMIF PARA ONDE O CIRCUITO DE ACESSO IR APONTAR( USADO O "PRIMARY"): #1675: * SPOPIPP02 L ATMIF/131 UNI ADDR/* AtmIf/131 Uni Addr/39076F0015010109020000000013010000000000,primary AtmIf/131 Uni Addr/39076F001501010902000000000020480D008300,default ok 2006-08-11 16:37:10.51 ------------------------COMANDOS PARA CONFIGURAR:----------------------#ENTRAR NO MODULO OCOOSPP03 ST P #ADICIONAR FRATM OCOOSPP03 ADD FRATM/30103 #CONFIGURAR LMI OCOOSPP03 SET FRATM/30103 LMI PROCEDURES AUTOCONFIGURE #ADICIONAR POSIO NA E1 OCOOSPP03 ADD LP/3 E1/1 CH/3 #CONFIGURAR O CN 3 PARA O TS 3 (IMPORTANTE RELACIONAR O CANAL AO TIME SLOT) OCOOSPP03 SET LP/3 E1/1 CH/3 TS 3 #ATRIBUIR A POSIO AO SERVIO OCOOSPP03 SET FRATM/30103 FRAMER INTERFACENAME LP/3 E1/1 Channel/3 #ADICIONAR O DLCI OCOOSPP03 ADD FRATM/30103 DLCI/16 #CONFIGURAR O DLCI E O EIR OCOOSPP03 SET FRATM/30103 DLCI/16 SP CIR 64000,BC 64000,BE 0 #ADICIONAR SERVIO SIWF
OCOOSPP03 ADD FRATM/30103 DLCI/16 SIWF #ADICIONAR SERVIO SPVC OCOOSPP03 ADD FRATM/30103 DLCI/16 SIWF SPVC #APONTAR O DLCI PARA O VCC DO ATMIF OCOOSPP03 SET FRATM/30103 DLCI/16 SIWF SPVC RDDR 39076F0015010109020000000013010000000000,RCI 0.56 #ADICIONAR O SERVIO DE ENDEREO OCOOSPP03 ADD FRATM/30103 ADDR #CONFIGURAR O ENDEREO (O "x" DEVE SER MINSCULO) OCOOSPP03 SET FRATM/30103 ADDR ADDR x.72511408030103
CONFIGURAR E APONTAR UM FRUNI ----------------------------------------------------------------------------#ENTRAR NO MODULO OCOOSPP03 ST P #ADICIONAR FRUNI OCOOSPP03 ADD FRUNI/30103 #CONFIGURAR LMI OCOOSPP03 SET FRUNI/30103 LMI PROCEDURES AUTOCONFIGURE #ADICIONAR POSIO NA E1 OCOOSPP03 ADD LP/3 E1/1 CH/3 #CONFIGURAR O Ch 3 PARA O TS 3 (IMPORTANTE RELACIONAR O CANAL AO TIME SLOT) OCOOSPP03 SET LP/3 E1/1 CH/3 TS 3 #ATRIBUIR A POSIO AO SERVIO OCOOSPP03 SET FRUNI/30103 FRAMER INTERFACENAME LP/3 E1/1 Channel/3 #ADICIONAR O DLCI OCOOSPP03 ADD FRUNI/30103 DLCI/16 #CONFIGURAR O EIR OCOOSPP03 SET FRUNI/30103 DLCI/16 SP CIR 64000,BC 64000,BE 0 #APONTAR A POSIO PARA COMUNICAR COM OUTRA PONTA OCOOSPP03 SET FRUNI/30103 DLCI/16 DC 72511630040120,DLCI 114
// /