Read these instructions carefully before use and keep them for future reference. The original
instruction is in Italian. All non-Italian instructions are translations of the original instruction.
Information and specifications on this manual could be uncorrect or could have printing errors.
Specifications are subject to change without notice.
Version: R1-11-13
NORME CE
EC RULES (STANDARD EC)
NORMAS DE LA CE
⎬
Direttiva Basso Voltaggio
Low Voltage Directive 2006/95/CE
Directiva de baja tensión
⎬
Direttiva EMC Compatibilità Elettromagnetica
EMC electromagnetic compatibility directive 2004/108/CE
EMC directiva de compatibilidad electromagnética
⎬
Norme armonizzate europee nell’ambito della direttiva
European harmonized standards underdirective 2006/42/CE
Las normas europeas armonizadas conforme a la directiva
Danger!
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Warning!
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
⎘ Cross reference - An instance which refers to related information elsewhere in the same
document
2
purpose of use METERING pump is intended for chemical dosing.
AND SAFETY
Use the pump in accordance with the data and specifications printed on the label.
Do not modify or use in a manner inconsistent with the provisions of the operating manual.
Keep the pump protected from sun and water. Avoid water splashes.
In emergencies the pump should be switched off immediately. Disconnect the power
cable from the power supply.
When using pump with aggressive chemicals observe the regulations concerning the
transport and storage of aggressive fluids.
Manufacturer is not liable for any unauthorized use or misuse of this product that may
cause injury, damage to persons or materials.
Pump must be accessible at all times for both operating and servicing. Access must
not be obstructed in any way.
Pump and accessories must be serviced and repaired by qualified and authorized
personnel only.
3
Environmental Work area
safety Always keep the pump area clean to avoid and/or discover emissions.
Recycling guidelines
EWC code: 16 02 14
Distributor
Spare parts For spare parts orders or any other communication, refer to the pump’s label.
Code (CODE) and serial number (S / N) uniquely identify the pump.
4
Transportation and A not suitable transportation or storage can cause damages.
storage
Use origianal box to pack the pump.
Although packed, always protect the unit against humidity and the action of
chemicals.
Before return the dosing pump to the manufacturer Repair service, drain the chemical
from pump head and rinse it. Refer to ⎘ Shutdown procedure.
Fill the PRODUCT SERVICE REPAIR FORM and send it with the dosing pump.
Repair service is not accepted if PRODUCT SERVICE REPAIR FORM is missing.
Included into
package
QUANTITY CONTENT K PLUS K CL PLUS K CO PLUS
n. 4 ø6 dibbles ⚫ ⚫ ⚫
4,5 x 40 self tapping
n. 4 ⚫ ⚫ ⚫
screws
n. 1 5 X 20 delayed fuse ⚫ ⚫ ⚫
level probe with axial
n. 1 ⚫ ⚫
foot filter (PVDF)
0,3 bar injection valve
n. 1 ⚫ ⚫ ⚫
(PVDF)
m2 delivery hose (PVDF) ⚫ ⚫ ⚫
m2 suction hose (PE) ⚫ ⚫ ⚫
venting hose (PVC 4x6
m2 ⚫ ⚫ ⚫
transparent)
m 2,5 input signal cable ⚫
n.1 operating manual ⚫ ⚫ ⚫
5
DESCRIPTION
K PLUS K PLUS is a constant or proportional dosing pump with level control for chemical feeding into water.
In Constant dosing mode pump doses a constant quantity regularly as configured by the user.
In Proportional dosing mode pump doses a quantity proportionally to an input signal, digital (voltage
NSF/ANSI 61 free contact) or current (mA).
Flow rate is determined by the stroke length and by the stroke speed. The stroke length is adjustable
from 0 to 100% using the stroke length adjustment knob. However dosing accuracy is guarantee
within an adjustment range from 30% to 100%.
K CL PLUS K CL PLUS works in constant mode and has got level control.
6
Fig. 3. K PLUS - KA PLUS
K PLUS- detail on pump head with manual
venting
Venting knob
Delivery valve
To manual
venting hose
6 5 4 3 2 1
Suction valve
D D
Delivery
B
valve B
A Progettato da
Massimo_F
Controllato da Modificato da Data
16/11/2010
Toll. Gen.
0.05
A Suction valve
Materiale:
Edizione Foglio
A3emec 00 1/1
6 5 4 3 2 1
Power supply
7
Features
Power Supply Fuse
230 VAC (180-270 VAC) - 50/60 Hz 1A
115 VAC (90-135 VAC) - 50/60 Hz 500 mA
24 VAC (20-32 VAC) - 50/60 Hz 2A
12 VDC (10-16 VDC) 2A
Environment temperature..........................10 ÷ 45°C (55 ÷ 113°F) - 50/60 Hz
Chemical temperature...............................0 ÷ 50°C (32 ÷ 122°F) - 50/60 Hz
Transportation and storage temperature....10 ÷ 50°C (55 ÷ 122°F) - 50/60 Hz
Installation class .......................................II
Pollution level...........................................2
Audible noise............................................73,4 dbA (silenced: 70,4 dbA; ultrasilenced: 69,4 dbA)
Protection degree......................................IP 65
Max installation height..............................1,5 m
Capacity ...................................................⎘ Table 1 and 2
1802 0,06 2 0,000016 0,53 0,06 0,19 180 18 261 2.7 1.45 4x6 4x6 L
1504 0,11 4 0,000029 1,06 0,11 0,37 180 15 217 2.7 1.45 4x6 4x6 L
1005 0,14 5 0,000037 1,32 0,14 0,46 180 10 145 2.7 1.45 4x6 4x6 L
0808 0,22 8 0,000058 2,11 0,22 0,74 180 8 116 2.7 1.45 4x6 4x6 L
0510 0,28 10 0,000074 2,64 0,28 0,93 180 5 72 2.7 1.45 4x6 4x6 L
0501 0,28 1 0,000008 0,3 0,03 0,09 180 5 72 2.7 1.45 4x6 4x6 L
0218 0,50 18 0,00013 4,76 0,50 1,67 180 2 29 2.7 1.45 6x8 6x8 M
1801 0,03 1 0,000008 0,26 0,03 0,09 180 18 261 2.7 1.45 4x6 4x6 LA
1503 0,08 3 0,000021 0,79 0,08 0,28 180 15 217 2.7 1.45 4x6 4x6 LA
103.5 0,10 3,5 0,000026 0,92 0,10 0,32 180 10 145 2.7 1.45 4x6 4x6 LA
085.5 0,15 5,5 0,000040 1,45 0,15 0,51 180 8 116 2.7 1.45 4x6 4x6 LA
057.5 0,21 7,5 0,000055 1,98 0,21 0,69 180 5 72 2.7 1.45 4x6 4x6 LA
0213 0,37 13 0,000098 3,43 0,37 1,20 180 2 29 2.7 1.45 6x8 6x8 MA
8
Tab. 2. Capacity (compressed air model)
CAPACITY
Flow cc per Max
stroke * pressure Delivery
Modello Suction Pump
min max Min Max hose
K AC PLUS hose head
cc/h l/h GPH GPH min max (PVDF)
bar PSI
Manual Max cc/stroke ( ⎘ Construction Materials and Technical info) are referred to cc/stroke with
stroke length stroke length knob on 100%.
adjustment
The stroke length knob adjusts the pump capacity. Press and rotate the knob when the pump is powered.
Note:if knob isn’t on 100% position then the pump will dose at pressure greater than the one
declared on label.
Materials ✓ : standard
✗: options available
9
INSTALLATION
How to install 5 steps to install and start-up the pump:
metering pump
1. Pump location
2. Piping connections (hoses, level probe, injection valve)
3. Wirings
4. Pump priming
5. Programming and start-up
Safety equipment
Use safety equipment according to the company regulations. Use this safety
equipment within the work area:
• Helmet
• Safety goggles (with side shields)
• Protective shoes
• Protective gloves
• Gas mask
Pump location Pump must be installed on a stable support at a max 1,5 mt height from tank’s bottom.
Injection point must be higher than tank to avoid accidental chemical injection.
8
1
Max 1,5 mt
11
PIPING CONNECTIONS
Foot filter / Level Level probe is assembled with a foot filter that avoid sediments priming probles.
probe Install level probe on the bottom of the tank.
(included only in Connect BNC level probe to the pump BNC input.
some models)
Warning: If there is a mixer installed into tank, install a suction lance instead of
level probe / foot filter.
STEP 5
STEP 4
STEP 3
INSERT PROBE
WITH N.O. CONTACT
UNTIL TO HEAR
A CLICK
STEP 2
INSERT FLOATER
STEP 1
12
Suction hose Suction piping should be as short as possible and installed in vertical position to
connection avoid air bubbles suction.
Completely unscrew tightening nut from pump’s head and remove assembling components: tightening
nut, holding ring and pipe holder.
Assembly as shown in fig. 5.
Insert hose into pipe holder until it reaches the bottom. Lock hose on pump’s head by screwing
down the tightening nut.
Suction hose
Threading nut
Holding ring
Pipe holder
Completely unscrew tightening nut from pump’s head and remove assembling components: tightening
nut, holding ring and pipe holder.
Assembly as shown in fig.6.
Insert hose into pipe holder until it reaches the bottom. Lock hose on pump’s head by screwing
down the tightening nut.
Delivery hose
Threading nut
Holding ring
Pipe holder
13
Injection valve Injection valve must be installed on plant from water’s input.
Injection valve will open at pressure greater than 0,3 bar.
On request 1, 2, 3, 4 or 5 bar injection valve are available.
8 7 6 5
Venting hose Insert one side of venting hose into discharge connector as shown in fig 8.
E
Fig. 8. Manual venting pump head model (K PLUS).
to delivery hose
Venting knob
To suction hose
During calibration procedure (“TEST”) insert venting hose into BECKER test-tube.
8 7 6 5
14
KA PLUS self Refer to fig. 9 for delivery and venting hose.
venting pump Assembling procedures are the same described before.
head connection
Fig. 9. Self-venting models pump head: IA, LA, MA, (KA PLUS).
To delivery hose
D
To suction hose
8 7 6 5
15
WIRING
Preliminary The electrical wirings should be carried out by AUTHORIZED AND
checks QUALIFIED PERSONNEL only in accordance with local regulations.
3. Install a relay switch. Do not install it in parallel with heavy inductance load (for
example: engines). See fig. 10.
P - Dosing pump
R - Relay
I - Switch or safety device
E - Electrovalve or inductance load
A - Power supply
4. Verify peak Amps. 115 or 230 VAC pumps do not use motor overload protection.
Power supply
12 VDC connect the pump to a 55 Ah-12VDC battery
24 VDC connect the pump to a 200W stabilized power supply (verify
peak Amps)
5. Verify level probe “BNC” is connected as described in ⎘ “Foot filter / Level probe”..
16
Pump’s wiring Connect external signal “BNC”to pump “INPUT”.
This signal can be:
- water meter input
- mA signal input.
6 5 4 3 2 1
C C
B B
Edizione Foglio
A3emec 00 1/1
Power supply 6 5 4 3 2 1
Level alarm output If present, connect level alarm (blue and brown wires).
(option) Level alarm is free contact and not fuse protected output.
Max load relay output: 2A 250VAC.
17
PRIMING
Chemical feeding must be stopped during backwash cycles and periods of noflow
as these conditions may introduce the potential for chemical overdosing. Not
doing so may result in elevated chemical concentrations and hazerdous gas intro-
duction into the pool or spa.
Never operate any pumping system with a blocked suction and discharge.
You must take all necessary measures to avoid this condition.
Safety equipment
Use safety equipment according to the company regulations. Use this safety
equipment within the work area:
• Helmet
• Safety goggles (with side shields)
• Protective shoes
• Protective gloves
• Gas mask
For viscous liquids, to facilitate priming: insert a 20 cc syringe on venting pipe and suck;
When syringe is almost full close the discharge valve turning the knob..
18
CONTROL PANEL
K PLUS K CL PLUS K CO PLUS
Keyboard
function PROGRAMMING MODE ENTER/EXIT
K PLUS
- STROKE FREQUENCY ADJUSTMENT (yellow labelled scale 0-100%) or
- DIVIDER MULTIPLIER FACTOR ADJUSTMENT N (grey labelled scale N: 1-10)
K CO PLUS / K CL PLUS
- STROKE FREQUENCY ADJUSTMENT (yellow labelled scale 0-100%) WITH CONSTANT 0-100% PROGRAM
- DIVIDER FACTOR ADJUSTMENT N (grey labelled scale N: 1-10) WITH CONSTANT 0-10% PROGRAM
PROGRAMMS LED
19
LEVEL led Red level led blinks in different ways described in the table
20
PROGRAMMING THE PUMP
Start/shutdown Connet power supply cable and start the pump with ON/OFF key.
Led will be on the last program set (default setting: ).
In OFF mode led will blink once every 2 seconds on the last program set (default setting: ).
If you do not press any key, after 30 seconds pump will esc from programming mode.
1
Not available on K CO PLUS and K CL PLUS models.
21
mA mode Current from an external device (BNC input) drives the pump that doses proportionally according to
the minimum and maximum set (0-20 mA or 4-20 mA).
To set press SCROLL until mA led turn on (red for 0-20 mA; green for 4-20 mA) and confirm with P
key.
STROKE FREQUENCY ADJUSTMENT (yellow labelled scale 0-100%) acts on injection per minutes.
CONSTANT mode Pump doses at a constant rate set with stroke length adjustment knob.
To set press SCROLL until CONSTANT led turn on and confirm with P key.
... there is not an external signal, and you have to dose a certain amount
To choose if...
of product regularly.
STROKE FREQUENCY ADJUSTMENT (yellow labelled scale 0-100%) acts on injection per minutes.
CONSTANT with Pump doses at a constant rate set with stroke length adjustment knob but this rate is divided by a
divider mode factor up to 10.
To set press SCROLL until CONSTANT and DIV 1÷10 led turn on together, then confirm with P key.
... there is not an external signal, and you have to dose a certain amount
To choose if...
of product regularly but pump capacity is too high
DIVIDER FACTOR ADJUSTMENT KNOB (grey labelled scale 1-10%) set the divider factor 1-10 to
reduce pump capacity.
22
MULT 1÷10 External pulses are multiplied by a value set by multiplier FACTOR ADJUSTMENT KNOB.
mode
To set press SCROLL until MULT 1÷10 led turn on, then confirm with P key.
... an external signal produces low pulses number. This working mode
To choose if...
multiplies pulses from 1 to 10 to dose the correct product amount.
multiplier FACTOR ADJUSTMENT KNOB (grey labelled scale 1-10) set the multiplier factor 1-10 to
increase pump capacity.
DIV 1÷10 External pulses are multiplied by a value set by DIVIDER FACTOR ADJUSTMENT KNOB.
DIV 10÷100
DIV 100÷1000 To set press SCROLL until DIV 1÷10 or DIV 10÷100 or DIV 100÷1000 led turn on, then confirm
mode with P key.
... an external signal produces high pulses number. This working mode
To choose if...
divides pulses to dose the correct product amount.
DIVIDER FACTOR ADJUSTMENT KNOB (grey labelled scale 1-10) set the divider factor to reduce
pump capacity:
• from 1 to 10 if in DIV 1÷10 mode
• from 10 to 100 if in DIV 10÷100 mode
• from 100 to 1000 if in DIV 100÷1000 mode
23
TROUBLESHOOTING
If the problem can not be solved, please contac after-sales service or return the dosing pump to the manufacturer.
Repair service Before return the dosing pump to the manufacturer Repair service, drain the chemical
from pump head and rinse it. Refer to ⎘ Shutdown procedure.
If there is the possibility that residual corrosive liquid into pump head could cause
damages, declare it on REPAIR FORM.
Fill the PRODUCT SERVICE REPAIR FORM and send it with the dosing pump.
Repair service is not accepted if PRODUCT SERVICE REPAIR FORM is missing.
24
Fuse replacement Make sure that the product is isolated from the power supply and cannot be powered
procedure by mistake.
Main board Make sure that the product is isolated from the power supply and cannot be powered
replacement by mistake.
procedure
25
Main board Fig. 12. Main board scheme
L N COIL
- OPTION
N.O.
C
N.C.
input
+ level -
26
MAINTENANCE
Maintenance In order to ensure the requirements of potable drinking water treated and the
schedule maintenance of the improvements as declared by the manufacturer, this equipment
must be checked at least once a month.
OPERATOR PROTECTION
Use safety equipment according to the company regulations.
Use this safety equipment within the work area during installation, service and
when handling chemicals:
• protective mask
• protective gloves
• safety goggles
• ear plugs or hear muffs
• further security device, if necessary.
Maintenance Shutdown the dosing pump before any maintenance operation ⎘ Shutdown
inspection procedure.
Three-month inspections
Perform these tasks every three months:
• Check that the tightenings.
• Check the mechanical seal if the pump has been left idle.
Annual inspections
Perform these inspections one time each year:
• Check the pump capacity (as per nameplate).
• Check the pump pressure (as per nameplate).
• Check the pump power (as per nameplate).
27
f the pump performance does not satisfy your process requirements, and the process requirements
have not changed, then perform these steps:
1. Disassemble the pump.
2. Inspect it.
3. Replace worn parts.
OPERATOR PROTECTION
Use safety equipment according to the company regulations.
Use this safety equipment within the work area during installation, service and
when handling chemicals:
• protective mask
• protective gloves
• safety goggles
• ear plugs or hear muffs
• further security device, if necessary.
Shutdown the dosing pump before any maintenance operation or before long downtimes.
Disconnect power and ensure it cannot be restarted.
28
Delivery curves Flow rate indicated is for H2O at 20°C at the rated pressure.
Dosing accuracy ± 2% at constant pressure ± 0,5 bar.
bar
bar
bar
bar
bar
29
0501: l/h 1 bar 5 0218: l/h 18 bar 2
Pump head mod. I Pump head mod. M
l/h l/h
bar
bar
30
Fig. 14. K A PLUS delivery curves
bar bar
bar bar
bar bar
31
32
33
Dimensions
Fig. 15. Dimensions
COMPATIBILITY TABLE
Chemical Solenoid driven metering pumps are widely used to dose chemical fluids and it is important that the
compatibility most suitable material in contact with fluid is selected for each application. This compatibility table serves
table
as a useful help in this respect. All the informations in this list are verified periodically and believed to
be correct on the date of issuance. All the informations in this list are based on manufacturer’s data
and its own experience but since the resistance of any material depends by several factors this list is
supplied only as an initial guide, in no way manufacturer makes warranties of any matter respect to
the informations provided in this list.
Product Formula Ceram. PVDF PP PVC SS 316 PMMA Hastel. PTFE FPM EPDM NBR PE
Amines R-NH2 1 2 1 3 1 - 1 1 3 3 1 1
1
Calcium Hypochlor.(Chlor.ted Lime): WQA test was based on 1% Calcium Hypochlorite solution.
34
Hose resistance Hose features are very important for a reliable dosage. Every pump’s model is made to work in the
table best way using selected hoses according to pump’s capacity / model. Information reported here are
intended for standard use only. For extended information ask to hose’s manufacturer.
35
36
MOD 7.5 B1 Q
Ed. 1 - rev. 0 21/02/2012
PRODUCT SERVICE REPAIR FORM
ENCLOSE THE PRESENT FORM TO THE DELIVERY NOTE
DATE .............................................
SENDER
Company name.............................................................................................................................................
Address .................................................................................................................................................
Phone no. .................................................................................................................................................
Contact person.............................................................................................................................................
OPERATING CONDITIONS
Location/installation description ...................................................................................................................
...................................................................................................................................................................
Chemical .................................................................................................................................................
Start-up (date)............................................. Running time (approx. hours).....................................................
remove all the LIQUID INTO THE Pump HEAD AND dry IT BEFORE packaging in its original box.
DESCRIPTION OF PROBLEM
MECHANICAL
Wear parts..................................................................................................................................
Brekage/other damages..............................................................................................................
Corrosion....................................................................................................................................
Other..........................................................................................................................................
ELECTRICAL
Connections, connector, cables....................................................................................................
Operating controls (keyboard, display, etc.)..................................................................................
Elettronics...................................................................................................................................
Other..........................................................................................................................................
LEAKS
Connections................................................................................................................................
Pump head.................................................................................................................................
Not or Inadequate function/other
..................................................................................................................................................
..................................................................................................................................................
..................................................................................................................................................
TABLES
Tab. 1. Capacity (manual and self venting models).................... 8
Tab. 2. Capacity (compressed air model).................................... 9
Tab. 3. Keys functions............................................................... 19
Tab. 4. Led LEVEL..................................................................... 20
Tab. 5. Led ProgramS............................................................ 20
Tab. 6. Programs menu............................................................. 21
Tab. 7. Guide to troubleshooting............................................... 24
Tab. 8. Chemical compatibility table.......................................... 34
Tab. 9. Hoses features............................................................... 35
39
When dismantling a pump please separate material types and send them according to local recycling disposal requirements.
We appreciate your efforts in supporting your local Recycle Environmental Program.
Working together we’ll form an active union to assure the world’s invaluable resources are conserved.
40