Bul81 - Spillway Shockwaves and Air Entrainement
Bul81 - Spillway Shockwaves and Air Entrainement
Bul81 - Spillway Shockwaves and Air Entrainement
4
of the Committee on Hydraulics for Dams,
with the assistance from W. H. Hager (Switzerland)
Original text in English-French translation par Y. Le May
NOTICE – DISCLAIMER :
The information, analyses and conclusions referred to herein are the sole
responsibility of the author(s) thereof.
This document has been drafted with the greatest care but, in view of the
pace of change in science and technology, we cannot guarantee that it
covers all aspects of the topics discussed.
Chairman/President
USA/Etats-Unis J. J. CASSIDY
Sub-Committee 1/Sous-Comite 1
Spain/Espagne J. A. HERRERAS
(coordinatorI coordinateur)
Brazil/Bresil A. RICOY DE OLIVEIRA
Chine/China SHEN CHONGGANG
France/France S. ALAM
Norway/Norvege D.K.LYSNE
Portugal/Portugal F. OLIVEIRA LEMOS
USSR/URSS V. M. SEMENKOV
Sub-Committee 2/Sous-Comite 2
USA/Etats-Unis J. J. CASSIDY
(coordinatorI coordinateur)
Netherlands/Pays-Bas P. KOLKMAN
Japan/ Japon M. HINO
USA/Etats-Unis A. H. MAKARECHIAN
Sub-Committee 3/Sous-Comite 3
Finland/Finlande M. AUTII (coordinator/coordinateur)
Canada/Canada M. DROUIN
Czechoslovakia/Tchecoslovaquie V. MATOUSEK
Denmark/Danemark H. MAI
Sweden/Suede L. BILLFALK
Sub-Committee 4/Sous-Comite 4
Germany/ Allemagne J. GIESECKE
(coordinatorI coordinateur)
Belgium/Belgique F. ZWAENEPOEL
Czechoslovakia/Tchecoslovaquie K. HAINDL
Switzerland/Suisse D. VISCHER
Sub-Committee 5/Sous-Comite 5
Finland/Finlande P. REITER (coordinator/coordinateur)
Australia/ Australie J. WINTON
Great Britain/Grande-Bretagne P.A. BACK
Spain/Espagne L. BERGA
South Africa/ Afrique du Sud A. ROOSEBOOM
2
SOMMAIRE CONTENTS
AVANT-PROPOS FOREWORD
l. INTRODUCTION l. INTRODUCTION
3
TABLE DES MATIERES
AVANT-PROPOS .................................................................................................................... 11
I. INTRODUCTION ............................................................................................................ 12
References ...... .. ........ .. .. ...... ...... .. .. ........ .. .. ...... ...... .. .... .. ...... .. ...... .. .. ...... .. ...... .. ...... .. .. ...... .. .. .. 22
4
TABLE OF CONTENTS
FOREWORD .......................................................................................................................... 11
I. INTRODUCTION ............................................................................................................ 13
References .... .. .. .. ............ ...... ...... .................... ...... .................................................... ........... 22
4. SPILLWAY AERATORS.................................................................................................. 95
4.1. Introduction ................................................................................................................ 95
4.2. Bottom Aeration .. ...... ...... .. .. ........ .. ...... .. .... ...... .. .......... ........ ...... .. ...... .. ...... .. ........ .. .. .. 97
4.3. Air Detrainment .......................................................................................................... 107
4.4. Design of Aerators .... ........ .. .. ........ .. ...... ...... ........ .. ...... .. ...... .. ...... .. ...... .. ...... .. .. .... .... .. I 09
4.5. Notation ...................................................................................................................... 113
4.6. References .................................................................................................................... 114
5
LISTE DES FIGURES
6
LIST OF FIGURES
Fig. 34. - Uniform aerated flow. a) Effect of air concentration on friction factor. b) Air
concentration distribution.
7
Fig. 35. --- Profil de la surface libre pour un ecoulement aere graduellement varie.
Fig. 36. - Zones de basse pression dues a des irregularites de surface et degats de surface.
Fig. 37. - Ecoulement a proximite d'un aerateur.
Fig. 38. - Dispositifs d'alimentation en air pour des deflecteurs.
Fig. 39. - Vue laterale d'un aerateur de coursier.
Fig. 40. - Aerateur de fond avec interface air-eau.
Fig. 41. - Representation graphique des equations (4.2) et (4.7).
Fig. 42. - Profil en long d'un coursier s'adaptant a la topographie.
Fig. 43. - Aerateur pour une forme concave de radier.
8
Fig. 35. - Free surface profile for gradually varied aerated flow.
Fig. 36. - Local low pressure zones due to surface irregularities and surface damage.
Fig. 37. - Flow in .the vicinity of aerator.
Fig. 38. - Air supply systems for chute flow deflectors.
Fig. 39. - Side view at chute aerator.
Fig. 40. - Bottom aerator with air-water interface.
Fig. 41. - Graphical display of eq. (4.2) and (4.7).
Fig. 42. - Longitudinal chute profile with adaptation to topography.
Fig. 43. - Aerator for concave bottom geometry.
9
A VANT-PROPOS
FOREWORD
Spillways and bottom outlets constitute a significant percent of the total cost of
major dams. Their proper design is, thus, very important from the standpoint of
economy as well as safety. This Bulletin, which considers the hydraulic concepts of
design for high-velocity flow, aeration, cavitation and shock waves, has been
prepared as a general design guideline for use of engineers engaged in the design of
bottom outlets and steep spillway chutes.
The comprehensive review, presented in this Bulletin, was performed by
Subcommittee No. 4 of the Committee on Hydraulics which was established in 1987.
The working group of the Subcommittee, which developed the successive drafts for
this Bulletin, was formed by the representatives of the German and Swiss National
Committees.
We wish to thank W. H. Hager, Switzerland, who carefully wrote the basis of
the four chapters; thanks are also due to the members of the Subcommittee who
contributed strongly to the development of the Bulletin. In addition we wisk to thank
the eight National Committees who provided comments on the initial draft, the
incorporation of which provided definite improvements.
J. J. Cassidy J. Giesecke
Chairman, Committee Coordinator,
on Hydraulics for Darns Subcommittee No. 4
11
1. INTRODUCTION
(*) Les chiffres entre crochets renvoient a la liste des references de chaque chapitre.
12
1. INTRODUCTION
Two major parts of a dam are the spillway and the energy dissipator. The
spillway controls the overflow, particularly during periods of floods and conveys the
water away from the dam. The energy dissipator, on the other hand, receives the flow
at the foot of the dam and returns it safely back to the adjacent river or lake.
Between the spillway crest and the dissipator lies a certain region to be
connected by appropriate means. Two major points are of concern here : 1) due to
large differences of elevation between spillway crest and original river the kinetic
energy at the foot of the dam may be large and velocities can be of the order of 30
to 50 ms~ 1 ; 2) the horizontal reach between the two elements is small when the flow
is guided over the dam crest and falls through the air on an impact basin. The
distance can amount to hundreds of meters when the flow is in a spilling channel.
The latter is also referred to as spillway with stress on the word way where the
spilling occurs, or better to a chute. This connecting element will be considered
herein.
13
a)
- ~-J~ -
~-
Le chapitre 2 est consacre aux ondes de choc qui constituent des perturbations
stationnaires a la surface libre d'un ecoulement torrentiel. Le terme « onde de choc »
tire son origine de la dynamique des gaz et, en hydraulique, le terme « ondes
transversales » est plus approprie. La Fig. 2 donne des exemples caracteristiques de
formation d'ondes transversales. Dans Jes deux cas, ces ondes prennent naissance a
l'extremite aval des piles de l'evacuateur de crue et se manifestent sur une grande
longueur du coursier. Comme on le verra plus loin, ces ondes stationnaires sont
provoquees par toutes perturbations situees sur le coursier, telles que changement de
direction, retrecissements et elargissements, OU meme piles (Fig. 3). Le chapitre 2
aborde brievement la question des ondes transversales et indique Jes possibilites de
reduire Jes ondes de hauteur excessive.
14
Fig. 1
Concepts of spillway chutes.
Conception des coursiers d'evacuateurs de crue.
a) Smooth boundary roughness, combined with a} Faible rugosite des parois : ecoulement a
high-velocity chute flow and terminal energy grande vitesse sur le coursier et dissipateur
dissipator. d'energie ii /'extremite du coursier.
b) Rough chute bottom, combined with highly b) Coursier en forme de gradins (forte rugosite) ·
turbulent cascade flow and partial terminal ecoulement tres turbulent et dissipation
energy dissipation. d'energie reduite au pied.
15
a)
Fig. 2
Development of cross-waves in chutes of Itaipu Dam (Brazil/Paraguay).
Formation d'ondes transversales sur /es coursiers de /'evacua/eur de crue du harrage d'/taipu
( Bresi l/ Paraguayj.
a) Downstream view (VA W D 6200). a) Vue d'aval (VAW D 6200).
b) Upstream view (YAW D 4249). h) Vue d'amon/ (VAW D4249}.
16
'
Fig. 3
Development of cross-waves due to piers and gate chambers
(ASCE Task Committee, 1961) [II].
Formation d'ondes transversales dues aux piles et aux chamhres des vannes
(ASCE, 1961) [llj
17
Le chapitre 3 traite de l'entrainement d'air nature! dans Jes ecoulements sur Jes
coursiers. Etant donne que Jes publications sur ce sujet sont tres abondantes et
qu'aucune synthese n'existe jusqu'a maintenant, un bref aperyu general historique
sera presente sur cette question. Une distinction est faite entre la zone evolutive,
)'aeration naissante, l'ecoulement aere graduellement varie et I'ecoulement uni-
forme, par analogie avec Jes courbes de remous d'un ecoulement non aere dans un
canal. Des termes en seront tires pour Jes caracteristiques d'un ecoulement varie
intervenant dans I'etude d'un coursier : profondeur du melange air-eau, concentra-
tion moyenne de l'ecoulement air-eau, courbes de remous modifiees, ... Les meca-
nismes de I'entrainement d'air sont egalement examines. La Fig. 4 montre un
ecoulement entierement aere sur un coursier et indique la configuration de surface
agitee et tres aeree. Les photographies de la Fig. 5, publiees par Hickox en 1945 [4],
donnent un exemple d'ecoulement aere sur un coursier.
Fig. 4
Surface pattern of aerated chute flow, exposure time I 0 '
(according to Straub and Lamb, 1953) [IO].
Surface d'un ecoulement aere sur w1 coursier, temps d'exposition JO ' s
(d'apres Straub et Lamb, 1953) [JO}.
18
In chapter 3, the natural air entrainment in chute flow is discussed. Since the
literature on this topic is quite extensive, and no systematic review exists, a historical
summary is presented. Distinction between the developing region, incipient aeration,
gradually varied aerated flow and uniform flow is made, much in analogy to
backwater curves in non-aerated channel flow. Expressions are derived for various
flow characteristics involved in chute design, such as the mixture flow depth, the
average concentration of air-water flow and the modified backwater curves. The
mechanisms of air entrainment are also discussed. Fig. 4 shows a fully aerated chute
flow and reveals the rough and highly porous surface pattern. An example of aerated
chute flow is presented with reference to photographs originally published by
Hickox in 1945 [4] (Fig. 5).
Fig. 5
Aerated flow on steep chute. Norris Dam Spillway
where the effect of incipient aeration is well seen both for :
Ecoulement aere sur un coursier a forte pente. Evacuateur de crue du barrage Norris,
ou /'on voit bien la naissance de /'aeration dans /es deux cas :
Chapter 4 concludes the present study with spillway aerators. Such elements
were found adequate to counter cavitation damage. The aerator supplies the bottom
layer of chute flow with additional air, resulting in a sort of shock-absorber [12]. The
concrete surface is thus protected from damage. The problem of increasing the
channel side walls to account for the bulkage of the air-water mixture is also
19
murs lateraux du canal pour tenir compte du gonflement du melange air-eau. Le
chapitre presente des methodes pour l'etude des conduits d'alimentation en air et
pour !'estimation de la quantite d'air entrainee suivant la geometrie de l'aerateur. On
donne egalement des informations sur la perte d'air le long du couriser, ainsi que des
criteres pour determiner !'emplacement des aerateurs. La Fig. 6 represente un
aerateur dans un canal vitre et montre que l'entrainement d'air a partir d'aerateurs
de fond est un phenomene de « cisaillement ».
La vue d'un ecoulement sur un coursier est tres impressionnante (Fig. 7).
L'ecoulement est contr6le sur le seuil de l'evacuateur puis evacue par le coursier. A
l'extremite des piles des vannes, l'ecoulement commence souvent a entrainer de I' air,
l'eau devenant « blanche ». Suivant la pente du coursier et la valeur du debit evacue,
ce phenomene peut se produire plus a l'aval. Une fois l'ecoulement aere, un bruit
effrayant, des embruns et des rafales de vent se manifestent. L'energie de cette masse
d'air et d'eau, tres turbulente, doit etre efficacement dissipee dans un bassin
d'amortissement situe au pied du barrage.
Ow= 107.21/s
Fr= 7.36
,:\p=0
13 =fimax
Fig. 6
Chute aerator in a laboratory channel (VAW, 33173/12).
Aerateur d'un coursier en canal vitre (VAW 33173/12).
20
discussed. The chapter introduces procedures for designing both the air supply ducts
and determining the quantity of air entrained by a certain aerator geometry.
Guidance is given with regard to the loss of air along the chute, and criteria for
aerator positioning. Fig. 6 shows a lab aerator and stresses the fact that air
entrainment by bottom aerators is a shearing phenomenon.
A tail water view of a chute is very impressive (Fig. 7). The flow is controlled by
a spillway crest and then directed along the chute. At the end of gate walls, the flow
often starts to entrain air, that is the water becomes " white ". Depending on the
slope of chute and the discharge, this process may be shifted more downstream.
Once the flow is aerated, it is accompanied by a tremendous noise, spray
development and gusty winds. The energy of this highly turbulent mass of air-water
mixture must then be calmed down and be effectively dissipated by an appropriate
stilling basin located at the toe of dam.
........
Fig. 7
21
REFERENCES
l. CASSIDY J. J. and ELDER R. A. (1984): "Spillways of high dams". Developments
in Hydraulic Engineering 2, 159-182. P. Novak ed. Elsevier Applied Science
Publishers, London and New York.
2. FALVEY H. T. (1990) : "Cavitation in chutes and spillways". Water Resources
Technical Publication Engineering Monograph 42. US. Dept. Interior, Bureau of
Reclamation, Denver.
3. GUMENSKY D. B. (l 949) : " Air entrained in fast water affects design of training
walls and stilling basins ". Civil Engineering 19 ( 12), 35-37; 93.
4. HICKOX G. H. ( 1945) : " Air entrainment on spillway faces ". Civil Engineering
15 ( 12), 562-563.
5. ICOLD (1987) : "Spillways for dams". !COLD Bulletin 58, Paris.
6. LOCHER F. A. and Hsu S. T. (1984) : " Energy dissipation at high dams ".
Developments in Hydraulic Engineering, Vol. 2, 183-238, P. Novak ed. Elsevier
Applied Science Publishers, London and New York.
7. NOVAK P. and CABELKA J. (1981): "Models in Hydraulic Engineering". Pitman,
Bosten.
8. SORENSEN R. M. (l 985) : " Stepped spillway hydraulic model investigation ".
Journal of Hydraulic Engineering ASCE l l l (12), 1461-1472; 113 (8), 1095-1097.
9. STEPHENSON D. (1988): "Stepped energy dissipators ".The Internal. Symposium
on Hydraulics for High Dams, Beijing, 1228-1235.
JO. STRAUB L. G. and LAMB 0. P. (1953). " Experimental studies of the air
entrainment in open channel flow ". V. JAHR Congress Minneapolis, 425-437.
11. Task Committee on Air Entrainment in Open Channels (1961)." Aerated flows
in open channels ". Proc. ASCE, J. Hydraulics Division 87 (3), 73-86; 87 (6),
221-231.
12. VISCHER D. ( 1985). " Die Schu13rinnenbeliiftung als Ma13nahme gegen
Kavitationserosion ". Osterreichische Wasserwirtschaft 37 (3/4), 117-123.
13. VITTAL N. and POREY P. D. (1987)." Design of cascade stilling basins for high
dam spillways ". Journal of Hydraulic Engineering ASCE, 113 (2), 225-237.
22
2. ONDES DE CHOC SUR LES COURSIERS
2.1. INTRODUCTION
Le nombre de Froude local
IF = V/c (2.1)
ou : V est la vitesse locale,
C, Ja vitesse de propagation OU ceJerite des ondes de surface, joue Un role
important dans Jes ecoulements a surface libre en canal. Pour un ecoulement
unidimensionnel, la celerite depend uniquement de la geometrie de la section
transversale et peut etre exprimee comme suit :
C = Vg A/Bs (2.2)
A, surface de la section transversale,
B" largeur en surface,
g, acceleration de la pesanteur.
Dans le cas d'un canal rectangulaire de largeur b et de surface transversale
A = bh, ou h est la profondeur de l'ecoulement, !'equation (2.2) donne :
C=Vg·h
Dans le cas d'un ecoulement peu profond bidimensionnel, la celerite peut
changer dans Jes directions transversale et longitudinale suivant la surface locale de
l'ecoulement.
Lorsque la vitesse locale est egale a la celerite, l'ecoulement est qualifie de
critique et IF= I. Lorsque IF< I, l'ecoulement est fluvial; lorsque IF> I, l'ecou-
lement est torrentiel. Le nombre de Froude dans la dynamique des fluides est
analogue au nombre de Mach en aerodynamique.
Les ecoulements fluvial et torrentiel ont un comportement tout a fait different,
en ce qui concerne l'etude mathematique du probleme. L'ecoulement avec IF < I a
un comportement elliptique, c'est-a-dire que des problemes aux limites doivent etre
resolus. Au contraire, l'ecoulement avec IF > I a un comportement hyperbolique
entrainant des particularites du type ondes. Ces dernieres constituent des problemes
caracteristiques le long du canal dans Jes deux directions, amont et aval. Chaque
obstacle dans le canal - par exemple, pile, deviation ou jonction de mur - cree une
perturbation distincte le long de courbes caracteristiques bien definies. Les perturba-
tions provoquent des ondes stationnaires a la surface de l'eau : creux ou - ce qui
est plus dangereux - surelevations. De telles ondes sont appelees ondes transversa-
les ou - par analogie avec la dynamique des gaz - ondes de choc. Dans Jes
ecoulements permanents, ces ondes ne se deplacent pas sauf pour Jes variations
turbulentes, et necessitent une revanche supplementaire. II y a done lieu de recher-
cher des moyens permettant de reduire de telles ondes.
Dans ce qui suit, la formation d'ondes transversales sera examinee, tout
d'abord, pour Jes deviations de mur de faible convergence dans un canal infiniment
large. La notion d'onde transversale sera introduite et Jes caracteristiques a l'amont
et a l'aval de l'onde seront determinees. Le cas du canal de largeur finie sera ensuite
examine et la forme des ondes de surface sera etudiee.
24
2. SHOCK WAVES IN CHUTES
2.1. INTRODUCTION
Open channel flows are significantly influenced by the local Froude number :
IF = V/c (2.1)
where : V is the local velocity and
c the propagation velocity or celerity of shallow water waves. The celerity
of a one-dimensional flow depends solely on the cross-sectional geometry
and may be expressed as
c = Vg AIB, (2.2)
A is the cross-sectional area, B, the surface width and g the gravitational
acceleration.
Flows where the local velocity is equal to the celerity are referred to as critical,
and IF = I. When IF < I, a flow is subcritical, and supercritical flows occur if
IF > I. The Froude number in fluid dynamics is analogous to the Mach number in
aerodynamics.
Subcritical and supercritical flows behave quite differently as regards the
mathematical solution process. Flows with IF < I behave elliptically, that is
boundary value problems must be solved. In contrast, flows for which IF > I are
hyperbolic problems that involve wave-type features. The latter are typical marching
problems both in the forward and backward directions. Each obstacle in the channel
- such as a pier, a wall deflection or a junction - creates a distinct perturbation
along well defined curves which are referred to as characteristics. The perturbations
result in standing water surface waves that are either troughs or - more
dramatically - wave peaks. Such waves are also termed cross-waves or - according
to gas dynamics - shock waves. For steady flow, these waves do not move except
for turbulent fluctuations, and demand additional freeboard. Means to reduce
cross-waves are thus of engineering concern.
In the following, the development of cross-waves will be first outlined for small
converging wall deflections in an infinitely wide channel. The notion of cross-wave
is introduced and quantities up- and downstream of a cross-wave shall be related.
Then, a channel of finite width is considered, and the pattern of surface waves is
studied.
25
On poursuivra par l'etude des retrecissements des canaux, en forme d'enton-
noir, d'eventail ou de tuyere. Cette derniere forme de retrecissement ne sera
d'ailleurs pas examinee. Les retrecissements en forme d'entonnoir sont efficaces
pour des rapports de contraction relativement eleves, c'est-a-dire lorsque la largeur
aval n'est pas inferieure a la moitie de la largeur amont (a l'entonnement). Pour des
rapports de contraction plus petits, comme dans le cas des entrees d'evacuateurs de
crue, le retrecissement en forme d'eventail est recommande.
Une autre disposition a examiner est l'elargissement du canal, bien qu'il attire
beaucoup mains !'attention que le retrecissement. La methode d'etude classique sera
presentee et !es resultats d'essais sur modele seront examines. Des ecoulements dans
des elargissements peuvent se produire sur des coursiers !ors de manreuvre de vannes
ma! equilibree ou dans des zones de transition entre pente raide et pente mains raide
d'un coursier.
...
V1
-7
"" ."-/ /v1n
~t
I< --
-,
~
--......
....-...
I
a)
th1
-V1
i - --
V2
--.-
-l\1
26
Next, channel contractions of funnel-shaped, fan-shaped, and nozzle-shaped
geometries are discussed. The latter will not be considered further. Funnel-shaped
contractions are efficient for relatively large contraction ratios, that is when the
downstream width is not less than half of the approaching width. For smaller
contraction ratios, as may typically occur at spillway entrances, the fan-shaped
contraction is recommended.
Rouse and Chow [6, 28] considered parallel supercritical flow in a wide
rectangular channel whose bottom slope is such that wall friction is compensated
(uniform flow). At a certain point, the wall is deflected towards the flow by the angle
+ 0 (Fig. 8 a). The wall deflection causes a perturbation of flow along a straight
curve whose deviation from the original direction of flow is p. P is referred to as
shock angle, and the corresponding curve as cross-wave. The shock angle Pis always
larger than the wall deflection 0.
Fig. 8
a) Wall deflection and notation for cross-wave. a) Deviation d'un mur et notation relative a
l'onde transversale.
b) Cross-wave in laboratory channel. b) Onde transversale dans un canal en
laboratoire.
27
En designant respectivement par Jes indices (I) et (2) Jes positions a l'amont et
a l'aval de l'onde stationnaire, !'application du principe des quantites de mouvement
et de !'equation de continuite donne [6J :
(2.4)
h2 = tg ~ (2.5)
h1 tg (~ - 8)
(2.6)
OU:
IF1 = V1/(gh1)112 (2.7)
est le nombre de Froude de l'ecoulement entrant et
y = h2lh1 (2.8)
est le rapport des profondeurs de l'ecoulement.
Le systeme d'equations a ete etabli en supposant que l'eau etait peu profonde,
c'est-a-dire que la pression etait hydrostatique et que Jes distributions des vitesses
etaient uniformes.
Pour des parametres donnes h 1, V1et 8, on peut calculer h 2, ~et IF2. Le systeme
d'equations ne conduit pas a des solutions precises, mais ii existe un graphique [15)
permettant d'obtenir les valeurs recherchees.
Dans le cas OU IF1 sin~ > I, I' equation (2.4) peut etre remplacee par !'equation
approchee suivante [10] :
(2.9)
~ = e+ 3_ IF11 (2.10)
2i/2
Pour~ < n/4 (45°) et IF 1 > 2, Jes valeurs caracteristiques tirees de !'equation
(2.10) presentent un ecart inferieur a 2° par rapport a la valeur exacte. De plus, on
peut representer le nombre de Froude aval IF2 par !'equation approchee :
(2.11)
28
Let indices (I) and (2) denote locations upstream and downstream of the
standing wave, respectively. The application of the momentum principle and the
continuity equation yields [6] :
(2.4)
hz = tg ~ (2.5)
h1 tg (~ - 0)
IF}= y- 1
[ IF 12 - /y (Y - l)(Y + 1) 2] (2.6)
in which
IF 1 = V/(gh 1) 112 (2.7)
is the approaching Froude number and
(2.8)
is the ratio of flow depths.
The set of equations was derived assuming shallow water, that is hydrostatic
pressure and uniform velocity distributions.
For given parameters h 1, V1 and 0, one may compute h 2, ~and IF 2 • The system
of equations cannot be solved explicitly but Ippen [15] prepared a diagram from
which the unknown quantities may be determined graphically.
For the case IF 1 sin ~ > l, Eq. (2.4) may be approximated by [IO] :
,;- l
Y = v 2 IF1 ·sin ~ - - (2.9)
2
(2.1 l)
29
Les equations (2.4) a (2.6) ont ete verifiees experimentalement par Ippen et
Harleman [17]. Pour I < Y < 2, on a observe des ressauts ondules tandis que Jes
fronts des ondes transversales etaient raides pour y > 2 et le passage de h1 a h2
presque brutal. Pour Y > 2, le present systeme d'equations concordait bien avec Jes
observations.
Exemple 2.1
Soit un coursier dont la pente du radier est S = 7 %, le debit unitaire (par metre
0
et !'on a :
VI = q/hl = 20 ms-I
IF 1 = Vil(gh 1) 112 = 7,37
2) L'angle de l'onde transversale p = 9,5°, d'apres !'equation (2.10).
3) La profondeur de l'ecoulement a l'aval de l'onde transversale est determinee
comme suit :
Y = 1,22 d'apres !'equation (2.9)
d'ou h 2 = 1,22 x 0,75 m = 0,915 m
4) Le nombre de Froude IF 2 = 6,6, d'apres !'equation (2.11); l'ecoulement aval
reste done torrentiel.
Une application du mur de deviation est le canal presentant un changement de
direction brusque mais faible. La Fig. 9 represente un canal dont le nombre de
Froude de l'ecoulement a l'entree IF 1 > 2. Aux points A et B, le canal change de
direction d'un angle 0. Au point A, le changement de direction rentre dans
l'ecoulement : la deviation du mur est qualifiee de « positive » et la profondeur de
l'ecoulement augmente. L'ecoulement est identique a celui precedemment examine
(Fig. 8). Au contraire, la deviation du mur au point B est « negative » et une onde
negative se forme avec diminution de la profondeur de l'ecoulement. Cette onde est
differente de l'onde positive du fait que le changement de profondeur est progressif
et non brutal.
30
Eqs. (2.4) to (2.6) were experimentally verified by lppen and Harleman [17]. For
< Y < 2, undular jumps were observed whereas the fronts of cross-waves for
Y > 2 were sharp, and the transition from h 1 to h 2 almost abrupt. For Y > 2, the
present system of equations compared well with observations.
Example 2.1
Given a chute of bottom slope S0 = 7 %, discharge per unit width q = 15 m2 s- 1,
roughness coefficient n = 0.011 sm- 113 • What is the flow depth downstream of a wall
deflection of e = 4°, if the approaching flow is uniform?
and thus
VI = q/hl = 20 ms-I
and IF 1 = V/(gh 1) 112 = 7.37
2) Angle of cross-wave p = 9.5° according to Eq. (2.10).
3) Flow depth downstream from cross-wave :
Fig. 9
Wall deflection and streamline pattern in a channel of finite width.
Deviation d'un mur et representation des /ignes de courant dans un canal de largeur finie.
( - ) Positive wave. ( - ) Onde positive.
(- - -) Negative wave. (- - -) Onde negative.
31
La zone a l'amont des ondes transversales, c'est-a-dire a gauche de ACB dans
la Fig. 9, n'est pas influencee par le changement de direction et Jes lignes de courant
restent paralleles au canal d'entree. Dans Jes zones ACE et BCD, Jes lignes de
courant sont paralleles aux murs du canal aval et Jes profondeurs de l'ecoulement
augmentent et diminuent respectivement.
Le point C est !'intersection des deux ondes transversales. Toutes deux pene-
trent dans des zones perturbees, mais aboutissent - en raison de !'inversion - a la
zone d'etat initial. II en resulte que Jes caracteristiques dans la zone CDEF sont
egales a h 1 et IF 1• Cependant, Jes lignes de courant ont devie de 2 8 par rapport a
la direction de l'ecoulement initial.
A l'aval de la ligne DFE, une inversion se produit de nouveau : Jes lignes de
courant deviennent paralleles aux murs. La profondeur de l'ecoulement augmente
dans la zone DFH et diminue dans la zone EFG. Le long du mur AEG, la surface
s'eleve tout d'abord brusquement puis tombe au-dessous de la profondeur initiale h 1•
L'ecoulement devient ainsi agite dans le canal, ce qui necessite des murs plus hauts
que ceux de la zone d'entree. Une partie importante de l'etude des coursiers porte
sur la reduction des sommets des ondes en vue d'obtenir un ecoulement presque
uniforme.
a)µv
32
The domain upstream of the cross-waves, that is on the left of ACB in Fig. 9,
is not influenced by the change of direction, and the streamlines remain parallel to
the approaching channel. In the two zones ACE and BCD, the streamlines are
parallel to the walls of the downstream channel, and the flow depths have increased
and decreased, respectively.
Point C is the intersection of two cross-waves. Both waves continue into
perturbed domains, but lead - due to inversion - to the domain of original state.
As a result, the characteristics in CDEF are equal to h 1 and IF 1• However, the
streamlines are deflected by 2 8 relative to the original flow direction.
Downstream from the curve DFE, inversion occurs again, and the streamlines
become parallel to walls. The flow depth increases in domain DFH, and decreases
in domain EFG. Along the wall AEG, the surface first rises suddenly, and then falls
below the initial depth h 1• The flow in the channel thus becomes tumbling and walls
higher than in the approaching zone are needed. An important consideration in the
design of chutes is the reduction of wave peaks to obtain almost uniform flow.
- boundary layers and curvature effects may locally modify the computational
model;
- slope effects and wall friction are not considered, and
- discharges other than the design discharge do not satisfy the conditions for
wave elimination.
These implications can only be accounted for when large physical models are
used or the flow is modelled numerically by an approach accounting for streamline
curvature effects. The basic methods of wave reduction should guide the more
involved modelling techniques.
The most effective means in reducing cross-waves is based on the principle of
wave interference. According to this principle, a negative wave is produced to
compensate for an identical positive wave. For example, a positive wall deflection
in a channel of finite width according to Fig. 10 a) is associated with an increase of
flow depth h 2 > h 1• In Fig. 10 b) the inverse is shown which leads to a decrease of
downstream flow depth.
Fig. 10
Principle of wave interference applied to channel of finite width.
Principe de /'interference d'ondes applique a un canal de largeur finie.
a) Increasing flow depth and IF 1 > IF,. a) Augmentation de la profondeur de /'ecoule-
ment et IF, > IF,.
b) Decreasing flow depth and IF 1 < IF,. b) Diminution de la profondeur de /'ecoulement et
IF, < IF,.
33
2.4. DEVIATION INFINIMEMENT PETITE D'UN MUR
tg~ d8
2
dh = (: ) (2.12)
1 (2.13)
8 - 8 1 = v'3·arctg [ v'3 !)112] -
(IF2 _
arctg [
(IF2 _
]
!)1/2
60°
40°
e-a1
20°
IF
0
1 3 5 7 9 11
34
2.4. INFINITESIMAL WALL DEFLECTION
The wall deflection 0 was previously assumed finite. For 0 -. O one may
consider the functions h and V as continuous. According to von Karman (37] the
following relation holds between flow depth and local velocity :
(~ ) tg~ d0
2
dh = (2.12)
(2.13)
e- e I = i/3. arctg [
(IF2 -
i/3 1)112] - arctg [
(IF2 -
I
1)112
]
is obtained for the function 0 (IF), where 0 1 = 0 (IF 1) in [rad] corresponds to the
integration constant depending on the approaching Froude number IF 1. For IF > 2
the approximation
holds better than 5 % (Fig. 11 ). For IF > 4, Eq. (2.14) can even be simplified to :
2
= - (2.15)
IF
Fig. 11
Angle of wall deflection (8 - 8 1) as a function
of local Froude number IF according to Eq. (2.13).
Angle de deviation d'un mur (e - e 1) en fonction
du nombre de Froude local IF, d'apres /'equation (2.13).
Approximations : (- - -) Eq. (2.14), Approximations : (- - -) equation (2.14),
( ... ) Eq. (2.15). (. ..) equation (2.15).
35
Pour de grandes valeurs de IF, l'effet de la variation de la profondeur de
l'ecoulement est faible et on peut admettre la vitesse constante V = V 1 au lieu de
H = H 1• Dans ce cas, la profondeur locale d'ecoulement h varie comme suit (22]
(2.16)
, IF 1 = -V1-
OU
Vgh1
Une deviation de mur positive + 8 conduit a une augmentation de profondeur
d'ecoulement h/h 1 > I. Des applications des methodes de von Karman et de Knapp
sont donnees dans le paragraphe 2.7.
l
I
I
I I
a) b) c)
+ +
36
For large IF the effect of variation in flow depth is small and one may assume
constant velocity V = V1 instead of H = H 1• Then, the local flow depth h varies as
(22] :
h
- =
IF2 · 2
I ·Sill (2.16)
h1
Fig. 12
Channel contraction.
Rerrecissement de canal.
a) Funnel. a) Entonnoir.
b) Fan. b) Eventail.
c) Nozzle. c) Tuyere.
37
Le retrecissement en forme d'eventail presente le mm1mum de deviations
elementaires et correspond ainsi a la forme optimale du point de vue geometrique.
En ce qui concerne le retrecissement en forme de tuyere, !'arc amont aura un rayon
plus petit que l'arc aval. Les retrecissements en forme d'entonnoir et en forme
d'eventail seront examines ci-apres.
Fig. 13
Schematic flow pattern in channel contraction according
to lppen and Dawson (1951) [ 16].
Representation schematique de /'ecoulement dans un retrecissement de canal,
d'apres lppen et Dawson (1951) [16}
38
The fan-shaped contraction has the mm1mum sum of elementary wall
deflections, and thus corresponds to the optimum shape from the geometric point
of view. As regards the nozzle-shaped contraction, the radius of the upstream arc
should be chosen much smaller than the second radius. In what follows, the
funnel- and the fan-shaped contractions will be considered.
A C,D
G)
®
a) + L1 L2--
L
•h2 ,----
b)
+h1
~-
____ J
Fig. 14
b
Design of funnel-shaped contraction according
to lppen and Dawson (1951) [16].
Conception d'un retrecissement de canal en forme d'entonnoir,
d'apres lppen et Dawson (1951) [16]
a) Plan view. a) Vue en plan.
b) Longitudinal section with surface profile b) Coupe longitudinale avec pro/ii de surface le
along(-) walls and (- - -) channel axis. long des murs ( - ) et dans /'axe (- - -) du
canal.
39
La Fig. 14 represente une nette amelioration de l'ecoulement, resultant d'un
choix correct de !'angle de retrecissement. Si l'onde transversale positive est dirigee
exactement vers le point D, !'interference des ondes se produit comme decrit
precedemment. L'ecoulement qui en resulte dans le canal aval n'a pratiquement pas
de perturbations de surface. II s'ensuit que seul l'ecoulement dans la zone (2) n'est
pas axial; la Fig. 14 b) represente des profils caracteristiques de surface, le long des
murs lateraux et le long de l'axe du canal.
Le cas represente par la Fig. 14 a fait l'objet d'etudes complementaires par
Harrison [l l] et Sturm [32]. D'apres Hager et Bretz [1 O], !'angle de retrecissement 8
peut etre determine par la formule approchee suivante
si 8 < lOo.
Pour de plus grandes valeurs de 8, Jes resultats devront etre verifies vis-a-vis de
!'engorgement, etant donne que IF 3 peut etre proche de l'ecoulement critique. Un
ressaut hydraulique se produit alors dans le retrecissement. De tels phenomenes sont
a ecarter dans tous les cas et on doit assurer une transition progressive de IF 1 a IF3 •
La conception sera basee sur une valeur minimale du nombre de Froude ava1 IF 3 >
2, de fa<;:on que 2 < IF 3 < IF 1.
L'etude se base sur le debit pour lequel la hauteur maximale de l'onde se
produit. Ce debit n'est pas connu a priori. On considere, en general, le debit maximal
comme debit de projet. Pour tous Jes autres debits, la forme du retrecissement ne sera
pas Conforme a )'equation (2.17). Le trace des ondes doit alors etre calcule suivant
Jes methodes presentees par Bagge et Herbich [4] OU dans le chapitre 2.8, en incluant
le frottement sur le mur. Des resultats preliminaires tires d'une etude sur modele
furent presentes par Cotta et Albina [7] pour Jes debits s'ecartant du debit de projet.
Exemple 2.2
Soit Jes caracteristiques de l'ecoulement entrant de l'exemple 2.1 : h 1 = 0,75 m
et IF 1 = 7,37. Quelle est !'angle optimal de convergence 8 si la largeur du canal
d'entree est b 1 = 20 met celle du canal aval b 3 = 15 m?
Avec r- 1 = b 1/b 3 = 1,333 et IF 1 = 7,37, )'equation (2.17) donne arctg 8 = 1,3°.
D'apres Hager et Bretz [10], le rapport des nombres de Froude est IF3 /IF 1 =
(l/2) (l + r) = 0,88, d'ou IF3 = 6,45 > 2. L'engorgement de l'ecoulement est ainsi
empeche.
40
Fig. 14 shows a significant improvement of flow pattern based on a correct
choice of the angle of contraction 8. If the positive cross-wave is exactly directed
to point D, wave interference occurs as previously described. The resulting tailwater
flow is then practically free from surface perturbations. As a consequence, only the
flow in domain (2) is non-axial, and Fig. 14 b) shows typical surface profiles both
along the side walls and the channel axis.
The design case as shown in Fig. 14 was further analysed by Harrison [I I] and
Sturm (32]. According to Hager and Bretz [10) an approximate expression for
contraction angles 8 < I 0° is
arctg 8 (2.17)
For larger 8, the result should be checked against choking as IF3 may be close
to critical flow. Then, a hydraulic jump occurs in the contraction. Such phenomena
must be avoided to provide a continuous transition from IF 1 to IF3 • The design should
be based on a minimum downstream Froude number IF 3 > 2, such that 2 < IF 3 <
IF1.
The design is based on the discharge with the maximum wave height. This
discharge is not known a priori. Usually, the maximum discharge is assumed as the
design discharge. For all other discharges, the contraction shape will not conform
to Eq. (2.17). The wave pattern must then be computed according to approaches
presented by Bagge and Herbich [4) or in section 2.8 by including wall friction.
Preliminary results from a model study for the off-design case were presented by
Cotta and Albina [7].
Example 2.2
Consider the approaching characteristics of example 2.1, that is h 1 = 0.75 m and
IF 1 = 7.37. What is the optimum angle of convergence 0 if the approaching width
b 1 = 20 m and the downstream width b 3 = 15 m are considered?
With r- 1 = b/b3 = l.333 and IF 1 = 7 .37, one may obtain from Eq. (2.17)
arctg 0 = l.3°. According to Hager and Bretz [I OJ, the ratio of Froude number is
IF/IF 1 = (1/2) (1 + r) = 0.88, thus IF 3 = 6.45 > 2. Choking flow is thus inhibited.
41
---• .~-rB-
~- ®
tbd
b) 1
Fig. 15
Fan-shaped contraction downstream from a spillway.
Retrecissement en forme d'eventail a /'aval d'un evacuateur de crue.
sont : une prise d'eau en forme d'eventail, un canal convergent et un coursier aval
prismatique. Le rapport de convergence est m = bd/bu et !'angle au centre y. Le
radier a l'aval de la zone d'entree est une surface plane et a generalement une pente
longitudinale Constante.
Les conditions d'ecoulement a l'entree (!) sont : la profondeur de l'ecoulement
h 1, la vitesse moyenne V1 et la charge H 1• En supposant un retrecissement entiere-
ment symetrique sans obstacles, tels que des murs guideaux, l'ecoulement tend a se
concentrer au centre de courbure M, la zone DE le long du mur lateral etant privee
d'ecoulement (Fig. 16). Cet effet est du a la composante de la force centrifuge
agissant sur Jes particules se depla9ant le long des lignes de courant courbes. La
profondeur maximale de l'ecoulement hM est situee au point C. Plus a l'aval, le profil
de surface dans !'axe diminue jusqu'au point F, puis atteint un deuxieme maximum
au point H.
L'onde transversale venant du point M intersecte lemur au point E. Sa hauteur
maximale hm se situe au point I, legerement a l'aval de E, et determine la hauteur
du mur lateral. Plus a l'aval, un ecoulement torrentiel avec surface agitee s'etablit.
42
A,
Fig. 16
Flow features in planar fan-type contraction.
Caracteristiques de /'ecoulement dans un ri!trecissement en forme d'eventai/.
a) Plan view. a) Vue en plan.
b) Axial cross-section. b) Coupe /ongitudinale dans /'axe.
c) Surface profile along the wall. c) Pro/ii de la surface le long du mur.
prismatic tailwater chute. The contraction ratio is m = bd/bu and the sector angle
y. The invert downstream from the entrance section is planar and normally of
constant longitudinal slope.
The flow conditions at the entrance section (1) are flow depth h 1, average
velocity V, and energy head H,. Assuming a fully symmetrical contraction without
any obstacles such as guiding walls, the flow tends to concentrate to the center of
curvature M, associated with a domain of zero flow along the side wall DE (Fig. 16).
This effect must be attributed to the centrifugal force component acting on particles
moving along curved streamlines. The maximum flow depth hM occurs at point C.
Further downstream, the axial surface profile decreases to a minimum at point F and
reaches a second maximum at point H.
The cross-wave from point M intersects the wall at point E. Its maximum hm is
slightly downstream at point I and determines the height of the side wall. Further
downstream the well-known and previously described tumbling surface pattern of
supercritical flow is established.
43
Les deux valeurs relatives YM = hM/H 1 et Ym = hm/H 1 dependent de IF 1 et de
la pente du radier S0 • Pour S0 "" IO% et y "" 40° ( = 0,70 rad), on obtient d'apres
Hartung et Knauss [12] :
YM = 3,66 y (2 + IF1 2)- 112 , l < IF, < 3,5 (2.18)
YM = 0,915 [I - (1,278 - y 2 (2 + IF/)- 112) 112
] IF 1 ~ 3,5 (2.19)
y etant exprimee en radian.
Pour d'autres pentes de radier, on peut ecrire Ym = a YM• OU a < l depend du
rapport de convergence m = bd/bu et du debit a l'entree. Des valeurs de m entre l/3
et 1/2 seront adoptees pour empecher la formation d'ondes transversales dans un
retrecissement en forme d'eventail. Les equations (2.18) et (2.19) peuvent etre
utilisees dans une etude preliminaire. Une etude complete devra, cependant, com-
prendre une· optimisation de la pente du coursier S0 , de !'angle au centre y et du
rapport de retrecissement m. Les resultats de Hartung et Knauss sont preliminaires
et s'appliquent exclusivement a une surface plane de radier. Le coefficient a depend
de plusieurs parametres et une etude sur modele est necessaire pour le projet final
des grands ouvrages.
Le Corps des Ingenieurs de I' Armee des Etats-Unis [35] a mis au point un
evacuateur de crue en forme d'eventail pour le barrage Genegantslet, New York. Le
projet definitif conduisait a une distribution reguliere de l'ecoulement au moyen de
!'augmentation de la longueur des murs d'entree. Les conditions d'ecoulement sur
le coursier etaient egalement ameliorees par un seuil triangulaire avec face amont
verticale, a l'entree du coursier, et par le realignement des murs lateraux. Michels [26]
a presente une etude dans laquelle un seuil avec avant busque est associe a un
coursier qui converge dans une auge.
Une surface de radier plane est une geometrie tres simple du point de vue de
la construction, mais est sujette a des restrictions en ce qui concerne l'hydraulique
de l'ecoulement. Anastasi [3] a etudie un retrecissement de coursier permettant de
supprimer, en grande partie, !es ondes transversales au moyen d'un radier ayant une
courbure transversale. La Fig. 17 represente un retrecissement de coursier, en forme
d'eventail, ayant une largeur b 0 a l'amont et une largeur bct a l'aval. La courbure du
mur a l'amont est I/Ru et la courbure varie le long du retrecissement suivant une
clotho.ide, c'est-a-dire que R- 1 = 0 a l'aval. La Fig. 17 indique egalement les lignes
de courant caracteristiques et !es lignes equipotentielles en forme d'arc circulaire de
longueur b;. ' est !'angle de convergence local et •u !'angle a l'entree.
Anastasi [2, 3] a presente une methode permettant de definir la geometrie de la
surface du radier du retrecissement; cette methode suppose une variation lineaire du
rayon de courbure transversal; au point P :
y2- S ·sm
-dz = - . (Rn;;)
0 (2.21)
dn g R
44
Both relative values YM = hM/H 1 and Ym = hm/H 1 depend on IF 1, and the
bottom slope S0 • For S0 " " 10 % and y "" 40° ( = 0.70 rad) Hartung and Knauss [ 12]
obtained :
YM = 3.66 y (2 + IF/)- 112 , 1 < IF 1 < 3.5 (2.18)
y2 .
-dz = --So·sm (Rn;;) (2.21)
dn g R
45
Fig. 17
Fan-type chute contraction. Notation.
Retrecissement de coursier en forme d'eventail. Notation.
/
I
Fig. 18
View of curved bottom geometry
of fan-type contraction (Anastasi, l 982) [3].
Vue en perspective de la geometrie courbe du radier
d'un retrecissement en forme d'eventail (d'apres Anastasi, 1982) [3]
46
a) b)
Pig. 19
Difrerences in flow surfaces - side view (lop) and plane (bouom).
Di!fere11ces de surface d'eco11/eme111 - en liaut : "" e de cote: cu bas : 1•11e e11 pla11.
a) Plane bouom. 01 Radier plan.
b) Curved bouom. h) Radier courbe.
47
Suivant !'equation (2.21), la pente transversale du radier est egale a la somme
du rapport entre l'acceleration centrifuge et !'acceleration de la pesanteur, et de la
composante de pente transversale due a la pente longitudinale S0 • La Fig. 18 donoe
une configuration caracteristique de radier.
Les vues ·de la Fig. 19 comparent des ouvrages de prise d'eau, en forme
d'eventail, pour deux geometries : a) radier plan, b) radier convexe. Les differences
de surface d'ecoulement sont significatives. Des essais ont demontre que les radiers
convexes amelioraient beaucoup l'ecoulement meme pour des debits differents du
debit de projet. Par rapport a la s uppression des ondes basee sur le principe de
!'interference (voir ci-dessus), le radier convexe peut ainsi etre considere com me une
adaptation souple a un ecoulement meme torrentiel.
Le principe de la compensation de I'acceleration centrifuge par I' acceleration de
la pesanteur fut applique par Vischer [36) aux elargissements, aux retrecissements en
forme d'eventail et aux raccordements. Actuellement, ce moyen de reduire les ondes
transversales est Jimite aux courbes de canal.
Les ecoulcments sortant d ' une conduite, d'un evacuateur de crue ou d'un
coursier a pente raide peuvent deboucher dans un canal aval de largeur plus grande.
Fig. 20
Cross-wave formation at abrupt channel expansion.
Fom101io11 d'ondes transversales dans rm elargisseme111 hn1sq11e d'un canal.
48
According to Eq. (2.21) the transverse slope of the bottom is equal to the sum
of the ratio between centrifugal to gravitational accelerations, and the transverse
slope component due to longitudinal slope S Fig. 18 shows a typical bottom
0 •
configuration.
Fig. 19 compares fan-type intake structures for the plane and the convex bottom
geometries. The differences in flow surfaces are significant. Experiments verified
that convex bottoms greatly improve flows even at non-design discharge. Compared
to the interference-type wave suppression as discussed previously in this section, the
convex bottom geometry may thus be regarded as a flexible adaptation to even
supercritical flow.
a}
-,- - -- ~~-- -- - - - - . --- - - · - - --· ---
b)
Fig. 21
Infinitely expanding channel.
Canal avec elargissement infini.
a) Plan view. a) Vue en plan.
b) Side view along channel axis. b) Profil le long de /"axe du canal.
49
Si la transition entre le canal etroit et le canal plus large est trop brusque, des ondes
transversales importantes peuvent se former comme le montre la Fig. 20. Par contre,
une transition trop progressive conduit a un ouvrage de grande longueur et couteux.
Rouse et al. [28] ont etudie des elargissements de canal dans lesquels la pente
de frottement est egale a la pente du radier. Pour un canal avec elargissement infini
(Fig. 21 ), on a demontre que la surface libre h (x, y) dependait seulement de la
profondeur h 1, de la largeur relative b 1/h 1et du nombre de Froude IF 1 = Q/(gb~hi) 112
de l'ecoulement entrant. Pour des canaux d'entree relativement larges (h/b 1 ~ I),
la distribution des pressions est presque hydrostatique sauf dans la zone laterale de
l'elargissement. La profondeur relative est donnee par
E_ = f (~. L, IF 1) (2.22)
h1 b1 b1
En outre, les deux parametres independants x/b 1 et IF 1 peuvent etre associes
lineairement sous la forme [(x/b 1)1F 1- 1]. La Fig. 22 donne une representation
graphique generale pour 2 < IF 1 < 8. Rouse et al. [28] ont determine une courbe
limite YL(x) contenant 90 % du debit, pour fe = I, et pouvant etre definie par
('equation suivante :
YL
b1
= !
2
[1 + f (-x-)112]
b1 IF1
e
(2.23)
1.5 -------~------,..-.-----------"T--------,
1 /
0.3
x
0.9 0.8 0.6 0.5 0.4 b11F1
0
0 0.5 1 1.5 2
Fig. 22
Generalized surface plot h/h 1 for 2 < IF, < 8
(Rouse et al., 1951) [28]. (- - -) Eq. (2.23).
Graphique general de la surface h/h 1 pour 2 < IF, < 8
(d'apres Rouse et al., 1951) [28]. (- - -) equation (2.23).
50
wider channel is too abrupt, large cross-waves occur as shown in Fig. 20. On the
other hand, if the transition is too gradual, the design is long and uneconomical.
Rouse et al. [28] considered the design of channel expansions in which the
friction slope equals the bottom slope. For an infinitely expanding channel (Fig. 21 ),
the free surface h (x, y) was found to be a function of the inflow depth h 1, the relative
inflow width b/h 1 and the inflow Froude number IF 1 = Q/(gbrhi) 112 • For relatively
wide approaching channels (h 1/b 1 < 1), the pressure distribution is almost
hydrostatic except for the lateral expansion area. Thus, the relative depth is given
by:
(2.22)
Further the two independent parameters x/b 1 and IF 1 may be combined linearly
into [(x/b 1)1Fj 1]. Fig. 22 shows a generalized contour plot for 2 < IF 1 < 8. Rouse,
et al. [28] determined a limit curve yJx) which enclosed 90 % of discharge,
for fe = I, and may be expressed as :
~~ ~ [I (b ~J ]
2
= + fe
1
(2.23)
y
2 b1
.
... ~ -~-·~-3 //"
-
.. ;,~/o~/ -~ bib1
1 -
-
~--/2
-
~-/
.... ··~--------
~
Fig. 23
Generalized geometry of expansion
with(. .. ) Eq. (2.23) with f, = 114 and (- - -) Eq. (2.24).
Representation geometrique generale d'un elargissement,
suivant /'equation (2.23) avec f.. = //4 (. .. )et /'e4uation (2.24) (- - -).
51
II ya lieu de noter que la Fig. 22 est seulement applicable aux faibles pentes de
radier. Pour Jes fortes pentes, l'ecoulement a tendance a moins s'etendre laterale-
ment.
Une zone de transition depuis le canal d'entree de largeur b 1 jusqu'au canal aval
de largeur b 2 est souvent necessaire. Pour des valeurs finies de b 2/b 1, on peut utiliser
!'equation (2.23) avec fe = 114 pour representer la courbe d'extension limite a
laquelle on doit ajouter une courbe convergente. La Fig. 23 presente une etude
generale. La longueur de la zone de transition L, est determinee comme suit :
(2.24)
Des etudes sur l'ecoulement torrentiel dans un elargissement ont ete egalement
effectuees par Koch [23] !ors de !'analyse de deux jets se heurtant contre un canal
horizontal, et par Herbich et Walsh [14] avec utilisation d'une methode numerique.
Cependant, leurs observations s'ecartaient beaucoup des resultats des calculs, ce qui
fut attribue au fait d'avoir neglige Jes effets du frottement sur le mur et de la
courbure. L'etude de Rouse peut servir d'approche grossiere dans un projet, bien que
la longueur de la zone de transition L, soit tres grande.
2.7. COURBES
52
Note that Fig. 22 is applicable only to small bottom slopes. For large slopes the
flow has a tendency to expand less laterally.
(2.24)
2.7. BENDS
53
IF- 1
o --
\
\
\
b/R "" " \
\
0.2
"2", CO\
\
\ \
\ \
R e \ \
\ I
t -----
IF-1
0
0
a) b) 0 0.2 0.4 0.6 0.8 1
Fig. 24
Supercritical flow in bend.
Ecoulement torrentiel dans une courbe.
a) Schematic flow pattern with • wave a) Representation schematique de /'ecoulement :
maximum and o wave minimum. • onde maximale, o onde minimale.
b) Angle 0 as a function of IF" 1
and b/R (Sinni- b) Angle e enfonction de IF;, I et de b/R (d'apres
ger and Hager, 1989) [31]. Sinniger et Hager, 1989) [31]
(2.26)
des ondes extremes peuvent s'exprimer sous la forme suivante tiree de l'eq. (2.26) :
(2.27)
Suivant I' equation (2.27), Ye est toujours du cote prudent et ne sera applique que
pour Jes faibles valeurs de b/R < 0,5.
54
3
Ye
·b/R o.os 0.2
2
0
0 0.2 0.4 0.6 0.8 1
Fig. 25
Extreme wave heights y, as a function of IF,, and b/R
(Sinniger and Hager, 1989) [31].
Hauteurs des ondes extremes y,. en fonction de IF,, et de b/R
(d'apres Sinniger et Hager, 1989) {Jlj
shown dashed in Fig. 24 b)) is a region of undular jumps. For large IF and 0
b/R < I 12, Eq. (2.25) may be approximated as :
(2.26)
The minimum and maximum (index « e »)wave heights can be computed with
Eqs. (2.16) and (2.25). In Fig. 25, Ye = ± h/h 0 are plotted as a function of
approaching Froude number IF and relative bend curvature b/R. Provided
0
Eq. (2.26) as :
(2.27)
Ye according to Eq. (2.27) is always on the safe side and should be applied only
for small values of b/R < 0.5.
55
Exemple 2.3
Soit un canal de largeur b = 15 m, de profondeur d'ecoulement h = 0,75 met
de nombre de Froude IF = 7,0. Quelles sont les caracteristiques de J'ecoulement
0
8 = 51,5°; d'ou ~ ± 112 8 = 8,2° ± 25,8°. Pour l'onde maximale, on a Ymax = 9,28
d'apres )'equation (2.16); la profondeur maximale de l'ecoulement est done dix fois
environ superieure a la profondeur de I'ecoulement a J'entree. A l'evidence, ce projet
est mauvais et on doit rechercher des moyens pour reduire J'onde maximale.
D'apres I' equation (2.27), les extremes des ondes augmentent de fa<;:on significa-
tive avec le nombre de Froude IF de I'ecoulement entrant; Jes ondes peuvent aussi
0
continuer a se manifester sur un long parcours dans le canal aval. Cela n'est pas
souhaitable des points de vue hydraulique et economique. Knapp [22] a propose un
certain nombre de moyens permettant de reduire les ondes dans des canaux courbes.
Ces moyens comprennent :
- Relevement de la courbe, en donnant au radier une pente transversale S,
pour s'opposer a la pente centrifuge. D'apres Jes principes de la mecanique, on a
St -- v~ (2.28)
gR
Le relevement doit etre progressif, en partant d'une pente transversale nulle au
debut de la courbe pour atteindre la valeur definitive a )'emplacement de la premiere
onde maximale. Le relevement presente un serieux inconvenient, a savoir que S,
depend de la vitesse V0 a I'entree et done du debit Q. Cependant, par rapport a
S, = 0, son effet pour un debit s'ecartant du debit de projet est une amelioration de
J'ecoulement.
- Ailettes courbes multiples, en inserant des elements concentriques dans Ia
courbe, ce qui conduit a une courbe plus etroite.
- Interference, comme cela est applique dans le cas des retrecissements.
Parmi ces trois methodes, le relevement s'adapte le mieux aux canaux ou la
vitesse d'entree ne varie pas beaucoup. Afin que le niveau maximal de la surface
reste bas, le mur interieur est abaisse (Fig. 26), ce qui peut conduire a un cout
d'excavation supplementaire. L'utilisation d'ailettes est restreinte a cause des trans-
ports solides. Egalement, Jes ailettes perturberont I'ecoulement et creeront une
nouvelle configuration d'ondes transversales. Un grave inconvenient des ailettes et
des seuils est le risque de cavitation pour des vitesses relativement grandes. Des
ailettes peuvent etre incorporees comme des piles de pont. Les courbes en spirale ne
sont pas recommandees du fait qu'elles n'ameliorent pas l'ecoulement. L'utilisation
de canaux non rectangulaires sera egalement evitee si possible. Les resultats
presentes s'appliquent a des nombres de Froude superieurs a 1,5 afin d'exclure Jes
ressorts ondules.
56
Example 2.3
Given a channel of width b = 15 m, flow depth h = 0.75 m and Froude number
IF = 7.0. What are the flow features in a curve of which the radius is R = 75 m and
0
According to Eq. (2.27) the wave extrema increase significantly with the
approaching Froude number IF Also, the waves may persist over a long reach in the
0
•
the tail water channel. This feature is undesirable both from hydraulic and economic
points of view. Knapp [22] suggested a number of means by which the wave pattern
in curved channels may be reduced. These include :
S t -- v; (2.28)
gR
The banking must be gradual, starting from zero transverse slope at the
beginning of curve to the final value at about the location of the first wave maximum.
A serious disadvantage of banking is that the slope S, depends on the approach
velocity V0 , and therefore on the discharge Q. Yet, its effect for off-design discharge
is improving the flow as compared to S, = 0.
57
Fig. 26
Curve banking at the " Dechargeur de Saint-Chamas ", Q = 60 m 3/s
(La Houille Blanche 3, 1966).
Relevement d'une courbe au dechargeur de Saint-Chamas, Q = 60 m 3/s
(La Houille Blanche 3, 1966).
D'autres etudes sur Jes ecoulements torrentiels dans des canaux courbes ont ete
realisees par Poggi [27J qui a compare Jes methodes de von Karman et de Ippen-
Knapp a ses experiences. Les conclusions furent les suivantes :
- Pour des courbes de faible courbure relative (b/R < 0,04) et de faible pente
de radier (S 0 < 5 %), les deux methodes indiquent de fa~on acceptable Jes ondes
extremes.
- Pour des courbures plus grandes et des pentes de radier plus fortes, la
methode de Ippen-Knapp peut etre recommandee. Ainsi, I' equation (2.16) au lieu de
!'equation (2.13) sera utilisee.
L'influence de la pente S du radier a ete analysee par Sananes et Acatey [29].
0
En se basant sur les experiences de Poggi [27], ils trouverent que la methode
d'Ippen-Knapp n'etait en accord avec les observations que si I'ecoulement le long
de la courbe etait accelere, c'est-a-dire lorsque la pente le long de la courbe etait au
moins deux fois plus grande que la pente S a I'entree. Le premier maximum d'onde
0
depasse egalement tous Jes autres maxima. Ces resultats obtenus egalement par
Krause [24] soutiennent grandement le concept de reduction des ondes par releve-
ment de la courbe.
58
rh
I I f
~ __111 _,;:;,;:;/ 3.0
=-- I 1---
l,I k
---7.5 I 0
t' -~-+~
1- 4.2-J 1@
2
Fig. 27
Combination of contraction and bend in a channel
with supercritical flow (Hartung and Knauss, 1967) [12].
Association d'un retrecissement et d'une courbe dans un canal
a ecoulement 10rrentiel (d'apres Hartung et Knauss, 1967) [12].
Further studies on supercritical flows in curved channels were due to Poggi [27]
who compared the approaches of both von Karman and Ippen-Knapp with his
experiments. He concluded that :
- For curves with small relative curvature (b/R < 0.04) and small bottom
slope (S 0 < 5 %) both approaches reasonably predict the wave extrema.
- For larger curvature and steeper bottom slope the approach of lppen-Knapp
as presented herein may be recommended. Thus, Eq. (2.16) instead of Eq. (2. 13)
should be used.
The effect of bottom slope S0 was analysed by Sananes and Acatey [29]. Based
on the experiments of Poggi [27], they found that the approach by lppen-Knapp is
in agreement with observations only if the flow along the curve is accelerated, that
is when the slope along the curve is at least two times as large as the approaching
slope S0 • Also, the first wave maximum is higher than all other maxima. These
findings which were also stated by Krause [24] greatly favour the concept of wave
reduction by curve banking.
59
Harrisson [11] a conduit des experiences sur Jes ecoulements a grande vitesse
dans des canaux de diverses formes. II constata des effets importants de la vitesse
et du rayon de la courbe sur la formation des ondes. C'est dans le canal rectangulaire
que Jes ondes sont le moins actives.
Hartung [13] a examine Jes aspects pratiques des ecoulements dans des coursiers
et a recommande des courbes equipees d'ailettes comme dispositif pour reduire Jes
concentrations d'ecoulement. La Fig. 27 donne un exemple d'association d'un
retrecissement avec une courbe dans un canal, tel que l'ont propose Hartung et
Knauss [12]. Le canal est divise en deux parties par un mur separateur, ce qui
permet de reduire de moitie l'effet de la force centrifuge. L'extremite aval du mur
separateur peut etre determinee suivant le principe des interferences d'ondes. Un tel
dispositif se limite a un certain domaine de debits au-dessous du debit de projet. Le
mur separateur peut aussi etre utilise comme support pour la couverture du canal.
La conception optimale doit etre etudiee sur modele hydraulique.
Un calcul de la surface d'un ecoulement torrentiel dans une courbe d'un canal
trapezoidal, Jes cotes lateraux ayant une pente m, a ete effectue par Lenau [25]. Le
cas h/R ~ I et IF0 > 2 fut considere, pour lequel Jes cretes des ondes deviennent
presque periodiques, comme cela est suppose dans la methode classique. La hauteur
maximale d'onde fut determinee par la formule suivante :
qui est analogue a l'equation (2.27) pour de faibles valeurs de b/R. La Fig. 28
presente des photographies d'ecoulement dans une courbe d'un canal trapezoidal,
d'apres Kleinschroth et Abelein [20]. Ils ont recommande :
- des courbes de transition, a double rayon de courbure, a l'amont et a l'aval
du coude,
un mur lateral exterieur raide (pente horiz./vert. = 0,5),
- une surface de radier rugueuse,
afin d'ameliorer l'ecoulement. L'effet de la pente transversale du radier sur la
reduction des ondes stationnaires etait faible et un canal rectangulaire devrait etre
normalement adopte. Une etude sur modele des courbes dans un canal trapezoidal
fut conduite par Kleinschroth et Siegerstetter [21]. L'equation (2.29) fut verifiee et
une revanche supplementaire se justifia pour l'entrainement d'air et Jes projections
d'eau.
Ellis et Pender [8] ont propose une solution au probleme des ecoulements
torrentiels, en se basant sur Jes observations de modeles. Ils ont resolu Jes equations
bidimensionnelles de l'ecoulement torrentiel permanent. Le programme de calcul du
systeme d'equations caracteristiques a donne des resultats satisfaisants en tenant
compte des effets de la pente, du frottement et d'autres elements relatifs a la
dissipation de l'energie. Les calculs furent appliques a des courbes simples, des
courbes en forme de S et des elargissements. II est reconnu que de tels calculs ne
peuvent remplacer les etudes sur modeles, mais on peut reduire la duree et le cout
des etudes sur modeles physiques en effectuant des etudes numeriques.
Un important developpement du calcul bidimensionnel des ecoulements a
surface libre est du a Jimenez et a Chaudhry [19], qui ont utilise des programmes de
calculs aux differences finies, explicites, concernant les ondes de choc. Si l'on tient
60
Harrisson [11] made experiments on high velocity flows in channels of various
shapes. He found appreciable effects of both velocity and curve radius on wave
generation. The lowest wave action occurred in the rectangular channel.
analogous to Eq. (2.27) for small b/R. Fig. 28 shows photographs of bend flow in
a trapezoidal channel according to Kleinschroth and Abelein [20]. They
recommended :
- transition curves of double radius of curvature both up- and downstream
from the bend,
- steep outer side wall of slope 0.5 (horizontal) to I (vertical), and
- rough outer side wall,
to improve the flow. The effect of transverse bottom slope on the reduction of the
standing wave pattern was small and a rectangular channel should be normally used.
A model study on bends in a trapezoidal channel was conducted by Kleinschroth
and Siegerstetter [21]. Eq. (2.29) was verified and an additional freeboard should
account for air entrainment and splash water.
Ellis and Pender [8] introduced an alternative to the design of supercritical flows
based on model observations. They solved the two-dimensional equations of steady
supercritical flow. The computational scheme for the system of characteristic
equations was effective in including effects of slope, friction and other energy
dissipating elements. The computations were applied to simple bends, S-shaped
bends, and expansions. Although these computations cannot replace model studies,
the time and cost of physical modelling could be reduced by performing numerical
studies.
61
a)
b)
Fig. 28
Bend flow in trapezoidal channel according
to Kleinschroth and Abelein ( 1985) [20].
Ecoulement dans une courbe d'un canal trapezofdal
(d'apres Kleinschroth et Abelein, 1985) [20}.
a) Smooth outer side wall. a) Mur lateral exterieur /isse
b) Rough outer side wall. b) Mur lateral exterieur rugueux.
62
2.5
2.0
1.5
1.0
0.5
9. 87
Y/Ho
a) 2. 5 0. 00
2 10
b)
X/HO -------- 59.61
-10
Fig. 29
Supercritical free-surface flow, flow direction left to right
(Jimenez and Chaudhry, 1988) (19].
Ecoulement torrentiel a surface fibre, direction de /'ecoulement
de la gauche vers la droite (d'apres Jimenez et Chaudhry, 1988) {19]
a) Computation of shock-reflection. a) Ca/cul de la reflexion de /'onde de choc.
b) 3 D-plot of water surface in circular-arc b) Representation tridimensionnelle de la surface
contraction - both for IF 4 and de /'ecoulement dans un retrecissement
Maccormack number v = 0.98. presentant une courbe circulaire - pour IF = 4
et une valeur v (nombre de MacCormack)
0,98.
63
compte correctement des conditions aux limites, on peut obtenir des resultats
satisfaisants. On a constate que l'hypothese de repartition hydrostatique des pres-
sions imposait des restrictions pour Jes ecoulements presque critiques.
La Fig. 29 donne deux solutions caracteristiques : calcul de la reflexion de
l'onde de choc et surface de l'ecoulement dans un retrecissement ayant une courbe
circulaire. Le rapport presente egalement en detail Jes techniques de calculs des
ecoulements a surface libre, dans le domaine bidimensionnel.
Actuellement, Jes modeles mathematiques relatifs aux ecoulements torrentiels
dans Jes canaux evoluent rapidement. Ence qui concerne l'ecriture des programmes,
ii semble important que des systemes explicites, avec une operation courante de
prevision-correction, fonctionnent avec succes. La definition des conditions aux
limites, la modelisation des sommets des ondes relativement raides et des effets du
frottement, posent encore quelques problemes.
Un excellent compte rendu des calculs numeriques des ecoulements a surface
libre est donne par Chaudhry [5].
64
for, favorable results may be obtained. The assumption of hydrostatic pressure
distribution was found to impose restrictions for nearly critical flows.
65
st (-] pente transversale du radier.
't (-] angle de convergence.
v [ms- 1] vitesse dans une section transversale.
x [m] coordonnee longitudinale.
c; [-] angle de la courbe.
y (-] rapport de profondeurs d'ecoulement.
y [m] coordonnee cartesienne transversale.
Ye [-] valeur relative de he.
z [m] cote du radier (du fond).
Indices
ecoulement a l'entree (amont).
2 ecoulement a la sortie (aval).
d a val.
u amont.
2.10. REFERENCES
66
st [-] transverse bottom slope.
't [-] convergence angle.
v [ms-'] cross-sectional velocity.
x [m] longitudinal coordinate.
~ [-] bend angle.
y [-] ratio of flow depths.
y [m] transverse cartesian coordinate.
Ye [-] relative value of he.
z [m] bottom elevation.
Suscripts
approaching flow.
2 tailwater flow.
d downstream.
u upstream.
11. HARRISON A. J.M. (1966) : " Design of channels for supercritical flow ". Proc.
Institution Civil Engineers (London) 35, 475-490; 36, 557-565.
12. HARTUNG F. and KNAUSS J. (1967) : " Developments to improve economy,
capacity and efficiency of structures controlling the passage of flood water
through reservoirs ". International Commission on Large Dams ICOLD, IX
Congress (Istanbul); Q. 33, R. 14, 227-249.
13. HARTUNG F. (1972) : " Gestaltung von Hochwasserentlastungsanlagen bei
Talsperrendammen ". Wasserwirtschaft 62 (1/2), 39-51.
14. HERBICH J.B. and WALSH P. (1972) : " Supercritical flow in rectangular
expansions ". Journal of Hydraulics Division ASCE, 98 (9), 1691-1700; 99 (8),
1276-1277.
15. IPPEN A. T. (1951) : "Mechanics of supercritical flow - a symposium". Part 1,
Trans. ASCE 116, 268-295.
16. IPPEN A. T. and DAWSON J. H. (1951):" Design of channel contractions". Trans.
ASCE 116, 326-346.
17. IPPEN A. T. and HARLEMAN D.R. F. (1956): "Verification of theory for oblique
standing waves ". Trans. ASCE 121, 678-694.
18. IPPEN A. T. and KNAPP R. T. (1936) : "A study of high-velocity flow in curved
channels of rectangular cross-section ". Trans. American Geophysical Union VII
Annual Meeting, 516-521.
19. JIMENEZ 0. F. and CHAUDHRY M. H. (1988) : " Computation of supercritical
free-surface flows ". Journal of Hydraulic Engineering ASCE, 114 (4), 377-395.
20. KLEINSCHROTH A. and ABELEIN R. (1985) : " Modelluntersuchungen iiber die
Wasserspiegellage in der Kriimmung einer Schu13rinne ". Mitteilung No. 44, Inst.
Hydraulik und Gewasserkunde, TU Munchen, P.-G. Franke ed., Munchen.
67
21. KLEINSCHROTH A. and SIEGERSTETTER L.A. (1986) : " Investigations of
supercritical flow in a curved section of an extremely rough channel ". XX
Convegno di Idraulica e Costruzioni Idrauliche (Padova) 873-884.
22. KNAPP R. T. (1951) : "Design of channel curves for supercritical flow". Trans.
ASCE, 116, 296-325.
23. KocH K. (1968) : " Die gegenseitige Strahlablenkung auf horizontaler Soble ".
Bericht Nr. 15, Versuchsanstalt fiir Wasserbau, Oscar v. Miller lnstitut, ed. F.
Hartung, Munich/Obernach.
24. KRAUSE D. ( 1970) : " EinfluB der Trassierungselemente auf den Spiegelverlauf
in gekriimmten SchuBrinnen ". Technischer Bericht No. 6, Institut Hydraulik und
Hydrologie, TH Darmstadt, R. Schroder ed., Darmstadt.
25. LENAU C. W. (1979) : " Supercritical flow in bends of trapezoidal section ".
Journal of Engineering Mechanics Division ASCE, 105 (EM I), 43-54.
26. MICHELS V. (1985) : " Rosslynne spillway : mitre-prowed overfall weir with
sharply convergent walls and skew-impact trough apron". XX/ /AHR Congress
(Melbourne) 3, 628-632.
27. POGGI B. (1956): "Correnti veloce nei canali in curva ". L'Energia Elettrica 34,
465-480.
28. ROUSE H., BHOOTHA, B. V. and Hsu E. Y. (1951) : " Design of channel
expansions ". Trans. ASCE 116, 1369-1385.
29. SANANES F. and ACATAY T. (1962) : " Contribution a l'etude des ecoulements
68
supercritiques dans des canaux coudes ". Comptes Rendus de l'Academie des
Sciences (Paris), 255, 1-3.
30. SANANES F. and XANTHOPOULOS T. (1965) : " Amelioration des conditions
d'ecoulement dans un canal courbe de section rectangulaire a forte pente ''.
Comptes Rendus de l'Academie des Sciences (Paris) 260, 801-803.
31. SINNIGER R. 0. and HAGER W. H. (1989) : " Constructions Hydrauliques -
Ecoulements Stationnaires ". Presses Polytechniques Romandes, Lausanne.
32. STURM T. W. (1984) : "Simplified design of contractions in supercritical flow".
Journal of Hydraulic Engineering ASCE, 111 (5), 871-875.
33. TAUBERT U. (1971) : " Der Abflul3 in Schu13rinnen-Verengungen ''. Der
Bauingenieur 46 (11), 385-392.
34. TAUBERT U. (1974) : " The design of spillway contractions using computer
simulation ". Water Power 26 (8), 282-287.
35. United States Army, Corps of Engineers ( 1952) : " Spillway for Genegantslet
dam Genegantslet creek, New York". Technical Memorandum 2-351. Waterways
Experiment Station, Vicksburg.
36. VISCHER D. L. (1988) : "A design principle to avoid shockwaves in chutes". The
International Symposium on Hydraulics for High Dams (Beijing), 391-396.
37. VON KARMAN T. (1938) : "Eine praktische Anwendung der Analogie zwischen
Oberschallstromung in Gasen und iiberkritischer Stromung in offenen
Gerinnen ''. Zeitschrift far Angewandte Mathematik und Mechanik 18, 49-56.
69
3. ENTRAINEMENT D'AIR NATUREL
3.1. INTRODUCTION
Le phenomene des ecoulements aeres revet un grand inten~t dans le projet des
canaux a forte pente, appeles aussi coursiers. L'entrainement d'air dans J'ecoulement
conduit a un melange air-eau et le gonflement de J'ecoulement aere necessite des
murs lateraux plus hauts que dans le cas d'un ecoulement non aere. L'inconvenient
du gonflement est compense par une suppression des degats par cavitation.
L'entrainement d'air dans un ecoulement sur un coursier concerne toujours un
ecoulement a grande vitesse, sous reserve que la rugosite aux parois presente les
caracteristiques habituelles. L'entrainement d'air dans un ecoulement sur coursier
est qualifie de nature), etant donne qu'aucun appareil externe, tel qu'un ventilateur,
n'est necessaire pour l'alimentation en air. Le processus d'entrainement d'air est lie
aux caracteristiques de turbulence. La presence d'air sous forme de bulles dans le
melange air-eau influe sur la turbulence. Comme Jes bulles montent vers la surface
libre, le melange est influence par Jes composantes longitudinale et transversale.
L'entrainement d'air a la surface sur Jes coursiers peut s'expliquer en se
reportant a la Fig. 30. A la sortie de la retenue, sur la crete de l'evacuateur de crue,
J'ecoulement s'accelere. Lorsque le niveau de turbulence a la surface libre est
suffisamment eleve, de l'air commence a etre entraine. Dans la zone d'acceleration,
l'ecoulement est designe sous le nom d'ecoulement non uniforme. Si la geometrie et
la rugosite du canal ne varient pas a I'aval, un ecoulement aere uniforme peut
s'etablir, ressemblant beaucoup a un ecoulement uniforme classique. Dans cette
zone, Jes distributions de la vitesse et de la teneur en air ne varient pas. Cet etat
d'equiJibre peut etre perturbe par des Variations de Ja pente du radier OU de )a Jargeur
du canal. II en resulte qu'un ecoulement aere graduellement varie se forme jusqu'a
ce qu'un etat d'equilibre soit retabli. L'ouvrage de sortie, tel que le saut de ski sur
la Fig. 30, ne sera pas decrit ici. Sauf indication contraire, tous Jes resultats presentes
concernent un coursier rectiligne.
---@---
70
3. NATURAL AIR ENTRAINMENT
3.1. INTRODUCTION
Air entrainment in chute flow is always related to high velocity flow, provided
the usual boundary roughness is considered. The air entrainment in chute flow is
said to be natural, as no external mechanism such as a fan is needed for the air
supply. The process of air entrainment is associated with the turbulence
characteristics. The presence of air in the form of bubbles in the air-water mixture
affects the turbulent structure. As the bubbles rise to the free surface, the mixture is
influenced by a combination of longitudinal and transverse components.
The surface air entrainment in chutes can be understood by referring to Fig. 30.
As water leaves the reservoir over the spillway crest, the flow accelerates. When the
turbulence level at the free surface is sufficiently high, air begins to be entrained. In
the accelerating region, the flow is referred to as non-uniform. If the channel
geometry and roughness do not vary further downstream, a uniform aerated flow
may be established, much in the manner of conventional uniform flow. In this
domain, both the velocity and air concentration distributions remain invariant. This
state of equilibrium may be perturbed by changes of bottom slope, or channel width.
As a result, gradually varied aerated flow occurs until a state of equilibrium is
re-established. The terminal structure such as the ski jump in Fig. 30 will not be
described herein. All results to be developed refer to a straight chute unless otherwise
stated.
Fig. 30
Schematic spillway with reservoir (left)
and ski jump (right).
Representation schematique d'un evacuateur de crue avec retenue (a gauche)
et saut de ski (a droite).
@ Regions of uniform flow. @ Zones d'ecoulement uniforme.
@ Regions of non-uniform flow. @ Zones d'ecoulement non uniforme.
@ Aerated flow (right). 0 Ecoulement aere (a droite).
(vj) Non-aerated flow (downstream from reser- (vj) Ecoulement non aere (a l'aval de la retenue).
voir).
71
Les paragraphes 3.2 et 3.3 traitent respectivement du mecanisme de l'entraine-
ment d'air et de !'emplacement de la formation de l'entrainement d'air. Dans le
paragraphe 3.4, l'ecoulement aere uniforme sera examine, tandis que le paragraphe
3.5 concerne l'ecoulement aere non uniforme. Un apen;:u historique sur Jes dudes
d'ecoulement accelere dans Jes coursiers termine le chapitre.
72
Sections 3.2 and 3.3 refer to the mechanism of air entrainment and the location
of incipient air entrainment. In 3.4, the uniform aerated flow will be discussed,
whereas section ;LS refers to non-uniform aerated flow. A historical account on the
development of accelerated chute flow concludes the chapter.
Volkart [57] postulated that air is entrained by droplets of water ejected from the
flow which, when falling back, entrain air bubbles (Fig. 31 ). Falvey and Ervine [ 13]
attributed the air entrainment on chutes to turbulence being continuously generated
within the flow along a chute.
The transport of bubbles into the flow requires a turbulent downward velocity
component larger than the bubble rise velocity. For typical air bubbles of I to I 0 mm
diameter, the rise velocity is about 0.30 ms- 1• Falvey and Ervine [13] were also able
to show that bubbles larger than 10 mm have a high probability of being entrained
but a small probability of being transported down into the flow. The opposite was
found for bubbles smaller than I mm in diameter. Bubbles of diameter between I
Fig. 31
Droplets above the water surface
(Volkart, 1980) [57].
Surface velocity 4.67 ms ',height of water column 40 mm.
Projection de goulles d'eau au-dessus de la sw:face de l'i!coulement
(d'apres Vo/kart, 1980) [57].
Vitesse a la surface 4,67 m/s, hauteur de colonne d'eau 40 mm.
73
!es bull es de diametre inferieur a 1 mm. Ce sont done !es bull es de 1 a I 0 mm que
!'on trouve le plus souvent, !es bulles de petit diametre etant reparties au-dessous de
celles de grand diametre.
Le depart de l'ecoulement aere peut facilement etre mis en evidence par I' « eau
blanche », tel que le montre Ia Fig. 5. Pour que l'entrainement d'air se produise,
Gangadharaiah et al. [ 15] donnent deux conditions : 1) I' energie cinetique des
remous en surface doit etre plus grande que l'energie de tension en surface, 2)
l'ecoulement doit avoir atteint un etat entierement turbulent.
Le niveau de turbulence minimal pour que l'entrainement d'air prenne nais-
sance peut s'exprimer sous la forme d'une vitesse de courant V [ms- 1) > 0,24/lf
pour des bulles de 5 mm de diametre, lf etant le coefficient de turbulence [13]. Le
coefficient de turbulence lr est defini comme le rapport de la racine carree
moyenne des variations des vitesses transversales a la vitesse moyenne de
l'ecoulement. La condition 1) pour qu'il y ait entrainement d'air est normalement
satisfaite sur Jes ouvrages reels.
Wood et al. [60) ont etabli la formule suivante pour l'epaisseur o de Ia couche
limite :
0
- = 00212 ( -x.)0.11 (x.)-0.10
- (3.1)
x ' H, k,
cette epaisseur etant independante de la forme de l'evacuateur pour des coursiers a
peu pres rectangulaires. Dans cette formule, H, est la difference de niveau d'eau
entre le niveau du reservoir et le point de depart de l'entrainement d'air, x la distance
par rapport a la crete de l'evacuateur, k, la hauteur de rugosite d'apres Nikuradse
(Fig. 32). L'equation (3.1.) indique que o augmente presque lineairement avec x, et
tres peu avec k,, mais cette acceleration (exprimee par HJ a un effet retardateur.
Le point de depart x = xi survient Iorsque la profondeur de l'ecoulement h est
egale a l'epaisseur de la Couche limite 0 (h = hi) = oi. II en resulte que le profil de
la surface libre doit etre defini par un calcul de ligne de remous et I' equation (3.1)
donnera o; (x;). Une autre methode par approximations successives fut egalement
presentee par Falvey [12] pour la localisation du point de depart de !'aeration.
74
to 10 mm are thus most commonly found, with small diameter bubbles distributed
below large diameter bubbles.
The onset of aerated flow may easily be visualised by the so-called white water
as shown in Fig. 5. Gangadharaiah et al. [15] quoted two conditions for inception :
I) the kinetic energy of the surface eddies must be greater than the surface tension
energy; and 2) the flow must have become fully turbulent.
1]
The minimum turbulence level for incipient air entrainment may be expressed
as streamwise velocity V [ms- > 0.24/ lf for bubbles of 5 mm diameter, with
lf as turbulence number [13]. The turbulence number lf is defined as the ratio of
root-mean square (rms) value of the transverse velocity fluctuations to the mean
flow velocity. Condition l) for incipient air entrainment is normally satisfied
for prototype structures.
The point of inception x = X; occurs if the flow depth h is equal to the boundary
layer thickness o(h = h;) = o;. As a result, the free surface profile must be computed
by a backwater procedure and Eq. (3. l) must be applied to determine o; (x;). An
alternative trial and error method for locating the point of incipient aeration was also
presented by Falvey [12].
Fig. 32
Occurrence of white water in chute.
Formation d"eau blanche sur un coursier.
75
Exemple 3.1
Soit un evacuateur de forme prismatique de pente 8 = 15° (S = 0,259) et de 0
hw = Joo (1 -
0
C) dy (3.2)
(3.3)
76
Example 3.1
Given a wide prismatic spillway of bottom slope 8 = 15° (S 0 = 0.259) and
equivalent roughness k, = 0.8 mm. Find the point of inception for a unit discharge
q = 25m 2 s- 1•
The energy head on the crest is H = 312 (q/g 112) 213 = 6 m according to the
critical flow formula. Based on a backwater computation, the free surface profile
may be given as indicated in the Table below. The longitudinal coordinate x has its
origin at the spillway crest. Also included are the location z of chute bottom below
the crest, the difference head H, = H-z-h and the thickness of boundary layer o
(Fig. 32) according to Eq. (3.1). The point of inception is located at xi = 120 m where
hi = 1.05 m.
In uniform aerated flow an equilibrium between body and retarding forces has
become established. Equilibrium flow may occur asymptotically at the end of long
prismatic chutes of constant bottom slope, but is physically more relevant as a
normalising quantity.
Let C be the local time-averaged air concentration defined as volume of air per
volume mixture. The equivalent clear water depth is then :
hw = f~0
(J - C) dy (3.2)
with y as coordinate perpendicular to the channel axis and with q as water discharge
per unit width. The average water (index " w ") velocity is :
Yw = _9_ (3.3)
hw
A characteristic depth of the air-water mixture is the depth h 90 where the average
air concentration is 90 %. The depth-averaged mean air concentration C may then
be defined as :
(3.4)
77
Rao et al. [35] ont etabli la relation suivante entre le rapport de la densite du
melange a la densite de l'eau, et la concentration moyenne d'air c :
(3.6)
Cain et Wood (5, 6] ont demontre que !'air entraine n'influern;:ait pas la
repartition des vitesses de l'ecoulement aere uniforme. Avec µ = v/V90, OU V90
q/h 90 , le profil des vitesses suivait la relation [7] :
µ = Y90116
(3.7)
independante de Ce. La profondeur relative d'ecoulement est Y90 = y/h 90 , comme
defini precedemment.
0.2
78
Rao et al. [35] correlated the density ratio of mixture to water flow and the mean
air concentration C as follows :
2-=l-l.lC (3.5)
Pw
Wood [61] was able to show that the air concentration profile and the velocity
distribution depend exclusively on the coordinate Y90 = y/h 90 and on the chute
slope 8. Fig. 33 shows the concentration profiles Ce (Y90 ) for various values 8. Index
" e " accounts for equilibrium flow.
Wood [61] also showed that the friction factor fe of equilibrium flow depends
on the relative roughness k/h, the hydraulic radius Rh and the mean air
concentration Ce. Using Straub and Anderson's data, the ratio f/fw depends only on
Ce. Herein, fw is the friction factor for pure water flow. For Ce < 20 %, the effect
of air-water mixture is negligible. For larger mean air concentrations Ce, the ratio
fe/fw decreases with increasing Ce. Wood presented a curve fe/fw as a function of Ce
for typical chute roughness (Fig. 34 a). It may be approximated as
(3.6)
Cain and Wood [5, 6] demonstrated that entrained air does not affect the
velocity distribution of uniform aerated flow. With µ = V/V90 where V90 = q/h 90 ,
the velocity profile followed the relation [7] :
(3.7)
independent of Ce. The relative flow depth is Y90 = y/h 90 , as previously defined.
Fig. 33
Concentration profiles C, (Y,,,) for uniform aerated flow
and various bottom slopes 8 according to Wood (1985) [61]
based on the data of Straub and Anderson ( 1960) [49].
Profils de concentration d"air C,. (Y",) dans un ecoulement aere uniforme
pour differentes pentes de radier e
(d'apres Wood, 1985 {61} et /es resu/tats obtenus par Straub et Anderson, 1960 [49}).
79
Le profil de concentration d'air d'un ecoulement aere uniforme peut etre
analyse en se referant aux etudes de Wood [59] et de Hager [17]. La Fig. 33 montre
que Ce (Y90) depend seulement de la pente du fond 8, en considerant la rugosite aux
limites du canal d'essai de Straub et d'Anderson. En designant par C 0 Ia concentra-
tion asymptotique au fond avec :
(3. 11)
Le parametre de coursier Q tient compte de la forme du canal et de la hauteur
de rugosite, et IFw = Vw/(ghw 3 ) 112 est le nombre de Froude de l'ecoulement d'eau
pure. Pour des canaux rectangulaires, on a obtenu le resultat - qui est inexact du
point de vue dimensionnel - n = 1,35 n, n etant le coefficient de rugosite de
Manning.
Avec hw = (l - Ce) h 99 , le rapport Y99 = h 99 /hw peut s'ecrire [44] :
y 99 = I + __l_,3_5_TJ~ (3. 12)
I + 2 (hwlb)
1 I 1
c
0.5 - 0.5
y*
I I
0
0.2 0.4 0.6 0.5 1 1.5
b) 0
80
The concentration profile of uniform aerated flow may further be analyzed
when following Wood [591 and Hager [17]. According to Fig. 33, Ce (Y90 ) depends
only on the bottom slope 0 for the boundary roughness existing in Straub and
Anderson's test channel. If C 0 is the asymptotic bottom concentration with
3
C0 = 1.25 0 [rad], 0° < 0 <40°
(3.11)
The chute parameter Q accounts for the channel shape and roughness height,
and IFw = Vw/(gh/) 112 is the Froude number of pure water flow. For rectangular
channels, the dimensionally incorrect result Q = 1.35 n with n as Manning's
roughness coefficient was found.
With hw = (l - C.) h 99 , the ratio Y 99 = h 99 /hw obtains [441 :
Y99 = I + t. 35 TJ (3.12)
I + 2 (hwlb)
Fig. 34
Uniform aerated flow.
Ecoulement aere uniforme.
a) Effect of mean air concentration on friction a) Effet de la concentration moyenne d'air sur le
factor. coefficient de frottement.
b) Air concentration distribution c (y*). h) Repartition de la concentration d"air c (r*).
81
ou T] = [hw sin 3 8/(g3 n 2)] 114 represente la caracteristique de rugosite dimensionnelle
du coursier. Pour les coursiers larges, la surface moyenne du melange eau-air Y 99
augmente lineairement avec T], c'est-a-dire essentiellement avec la pente e du
coursier, et tres peu avec le coefficient de rugosite. L'effet de la profondeur
d'ecoulement est tres faible. L'equation (3.12) est une base simple pour le calcul de
la profondeur h 99 de l'ecoulement aere uniforme sur le coursier, en considerant la
profondeur h" de l'ecoulement d'eau pure.
Les equations (3.11) et (3.12) peuvent etre transformees en rempla~ant le debit
par la formule de Manning. En se limitant aux coursiers larges (hw/b ~ I), la
concentration moyenne d'air Ce peut s'exprimer comme suit [17]
ce = 1,35 ri (3.13)
La concentration moyenne d'air a l'equilibre Ce depend principalement de la
pente e du coursier, comme l'indiquait aussi !'equation (3.10), et egalement du
coefficient de rugosite de Manning.
Exemple 3.2
Quelles sont Jes caracteristiques de l'ecoulement aere uniforme de l'exemple
precedent 3.1? Avec ks 116 /(ng 112 ) = 8,2 selon Strickler pour un ecoulement rugueux
turbulent, on obtient pour la rugosite de Manning la valeur n = 0,0119. En
outre, avec Q = 1,35 n = 0,016 et le nombre de Froude IFw = q/(ghw 3 ) 112 =
25/(9,81 x 0,72 3 ) 112 = 13,06, I' equation (3.11) donne pour Ce, concentration
moyenne d'air, la valeur de 43 % . L'equation (3.8) donne comme concentration au
fond la valeur approximative de 2,2 %. De plus, avec T] = 0,55 et hw/b ~ I, on obtient
pour la profondeur de l'ecoulement du melange air-eau Y99 = 1,75, et done h 99 =
1,28 m.
dh
sin e- Sr - h sin e (~)
(3.14)
2
dx cos 8 - IF
ou d8/dx correspond a la variation de la pente du fond et IF q/(gh 3) 112 est le
2
nombre de Froude. La pente de frottement Sr = (fa/ 4 Rh) (V /2 g) est calculee a
partir de !'equation (3.6) en tenant compte de la concentration d'air comme indique
precedemment.
82
in which TJ = [hw sin 3 E>/(g 3 n 2)] 114 is the dimensional chute roughness characteristics.
For wide chutes the mean surface of the air-water mixture Y99 increases linearly with
TJ, that is mainly with the chute slope E> and moderately with the roughness
coefficient. The effect of flow depth is very small. Eq. (3.12) is a simple basis for
computing the uniform aerated flow depth h 99 in chute flow when accounting for the
pure water flow depth hw.
Eqs. (3.11) and (3.12) may be developed further when substituting Manning's
formula for discharge. Restricting considerations to wide chutes (hJb < 1), the
mean air concentration Ce may be expressed as [17]
(3.13)
The average equilibrium air concentration Ce depends mainly on the chute slope
E> as was also predicted with Eq. (3 .10) and also on the Manning roughness
coefficient.
Example 3.2
What are the uniform aerated flow characteristics of example 3.1? With
k, 116 /(ng 112 ) = 8.2 according to Strickler for turbulent rough flow, Manning's
roughness value obtains n = 0.0119. Further, with Q = 1.35 n = 0.016 and the
Froude number IFw = q/(ghw 3) 112 = 25/(9.81 x 0.72 3) 112 = 13.06, the average air
concentration is Ce = 43 % according to Eq. (3.11 ). The bottom concentration C 0 is
2.2 %, roughly, from Eq. (3.8). Further, with T] = 0.55 and hw/b < 1 the mixture flow
depth obtains Y 99 = 1.75, thus h 99 = 1.28 m.
The region between the inception point and the uniform aerated flow is
gradually varied, and is referred to as gradually varied, aerated flow zone (Fig. 30).
This domain is characterized by a local variation of air concentration, velocity and
flow depth. The region is similar to gradually varied channel flow, except that both
air concentration C and density p are additional unknowns. Based on the similarity
of gradually varied and uniform flow as regards the friction slope [8] the concept of
similarity for air concentration profiles in aerated flow was stipulated [61]. The
equation for the surface profile then obtains :
dh
sin E> - Sr - h sin E> (~)
dx cos E> - IF2 (3.14)
where dE>/dx corresponds to the change of bottom slope and IF = q/(gh 3) 112 is the
Froude number. The friction slope Sr = (f/ 4 Rh) (V 2/2 g) is computed from Eq. (3.6)
by accounting for the effect of air concentration as previously discussed.
83
Une methode approchee considere la profondeur hum de l'ecoulement aere
uniforme comme la profondeur d'ecoulement asymptotique, mais utilise !'equation
relative a l'ecoulement non aere graduellement varie. lei, l'indice (( u » correspond
a « uniforme » et « m » au « melange air-eau ». Avec Jes parametres non
dimensionnels :
x = sin e. x/hum•
on obtient [44] :
(3.15)
84
An approximate procedure accounts for the uniform aerated flow depth hum as
the asymptotic flow depth but the equation for non-aerated gradually varied flow.
Index " u " refers to uniform and " m " to the air-water mixture. With the
nondimensional parameters :
x I
= sin e. x/hum,
the result obtains [44) :
dhm sin 0 - Srm
(3.15)
dx 1 - IF,;
Fig. 35 shows the solution Ym (X) for various values of Ye. Starting at the
inception point (xi; h) and with known uniform aerated flow depth hum and aerated
critical flow depth hem, the nondimensional inception point (Xi = sin 0 · x/hum;
y mi = h/hum) may be located on the plot.
Also, the curve with the desired Ye value is selected. Then one may proceed
downstream along the chute that is from left to right in the diagram to obtain the
... . . . 5
x..__ ym
4
Fig. 35 b)
Free surface profile Y m(X) for gradually varied aerated flow.
Profil de la surface fibre Y"' (X) pour un ecoulement aere graduellement varie.
( ... ) Critical flow. (. ..) Ecoulement critique.
b) - 100 ,,;;; x , ; ; - 20. b) - JOO ,,;;; X,,;;; - 20.
85
du graphique, a l'obtention du profil de la surface de transition aux points x choisis,
OU Jes profondeurs du melange sont hm = y mhum·
D'autres etudes relatives a la zone OU se developpe l'entrainement d'air ont ete
presentees par Keller et al. [28], et par Thandaveswara et Rao [51]. Leurs resultats
experimentaux peuvent etre utilises pour l'etalonnage des modeles numeriques.
86
transition surface profile at selected locations x, where the mixture depths are hm =
Ymhum·
Further contributions to the developing region were offered by Keller et al. [28],
as well as Thandaveswara and Rao [51 ]. Their experimental data may be used for
calibration of numerical models.
Apart from lab studies by Annemiiller ( 1961) [3], Rajaratnam ( 1962) [43],
Anderson (1965) [2], Killen and Anderson ( 1969) [31 ], and Lai (1968) [33], and field
observations by Okada et al. (1959) [42], Harrison and Owen (1967) [23] and Aki
(1969) [l], a second intense period of experimentation started in the Seventies.
Lakshmana Rao et al. (1968, 1970 and 1971) [34, 35, 36] developed a theoretical
approach for the concentration and velocity distributions in the free turbulent and
the wall turbulent zones. Incipient air entrainment and expressions for the average
entrainment coefficient were analysed by Gangadharaiah et al. ( 1968, 1970) [14, 15].
The developing region was investigated by Keller et al. (1974) [28] and Keller and
Rastogi (1975, 1977) [29, 30] applied further results on spillways. In parallel,
Thandaveswara and Lakshmana Rao (1978) [51] conducted an experimental study
on the developing region. Vol kart ( 1980, 1982) [57, 58] explained the mechanism of
air entrainment, and extended the results on partially filled pipes, whereas Falvey
( 1979) [ 11] proposed a relation for the average cross-sectional air concentration in
uniform aerated flow. Cain and Wood (1981 a, b) [5, 6] presented a novel
instrumentation and continued the experiments on the Aviemore dam. Wood et al.
(1983) [60] introduced a modified procedure for locating the incipient air
entrainment, and Wood (1983) [59] re-examined the uniform aerated flow and
presented a state-of-the-art report in I 985 [61], as did Rao and Kobus (1975) [37] and
Kobus (1985) [32], as well as Falvey (1980) [12] and Falvey and Ervine (1988) [13].
87
I'etat de la question en 1985 [61], ainsi que le firent egalement Rao et Kobus (1975)
[37], Kobus (1985) [32], Falvey (1980) [12], Falvey et Ervine (1988) [13]. Vers la fin des
annees 80, l'etude, sur modele mathematique, de l'ecoulement aere dans un canal a
surface libre fut entreprise. Des rapports furent etablis par Hopping et Hoopes
( 1988) [26) et par Chanson ( 1989) [7].
88
In the late 1980s, the numerical modelling of aerated open channel flow was
initiated. Contributions were made by Hopping and Hoopes (1988) [26] and
Chanson ( 1989) [7].
89
Indices
a air.
c ecoulement critique.
e equilibre.
naissance (debut).
m melange.
u ecoulement uniforme.
w eau.
3.8 REFERENCES
1. AKI S. (1969) : " Field measurements of velocity and pressure on spillway
chute ". XI II /AHR Congress Kyoto, 5 ( 1), 167-172.
2. ANDERSON A. G. ( 1965) : " Influence of channel roughness on the aeration of
high-velocity open-channel flow". XI JAHR Congress Leningrad, I (37), 1-13.
3. ANNEMULLER H. (1961) : "Die Berechnung der Abfluptiefen in Schuprinnen ".
Der Bauingenieur 36, 222-226.
4. BAUER W. J. (1954) : "Turbulent boundary layer on steep slopes". Trans. ASCE
119, 1212-1242.
5. CAIN P. and WOOD I. R. (l 981 a) : " Instrumentation for aerated flow on
spillways ". Proc. ASCE, J. Hydraulics Division 107 (l 1), 1407-1424.
6. CAIN P. and WooD I. R. ( 1981 b) : " Measurement of self-aerated flow on a
spillway ". Proc. ASCE, J. Hydraulics Division 107 (11), 1425-1444; 109 (I),
145-146.
7. CHANSON H. (1989) : " Flow downstream of an aerator - aerator spacing ".
J. Hydraulic Research 27 (4), 519-536.
8. CHOW V. T. (1959) : "Open channel hydraulics ".McGraw-Hill Book Company,
New York.
9. EHRENBERGER R. (1926) : "Wasserbewegung in steilen Rinnen mit besonderer
Beriicksichtigung der Selbstbeli.iftung ". Oesterreichischer Ingenieur- und Archi-
tektenverein 78 (15/16), 155-160; 78 (17/18), 175-179.
10. EHRENBERG ER R. ( 1930) : " Eine neue Geschwindigkeitsformel fiir kilnstliche
Gerinne mit starken Neigungen (Schusstennen) und Berechnung der
Selbstbelilftung des Wassers ". Die Wasserwirtschaft 23 (28), 573-575; 23 (29),
595-598.
11. FALVEY H. T (1979) : " Mean air concentration of self-aerated flows ". Proc.
ASCE, J. Hydraulics Division 105 (I), 91-96; 105 (11), 1469; 106 (8), 1407-1408.
12. FALVEY H. T (1980) : " Air-water flows in hydraulic structures ". US Dept.
Interior, Water Resources Technical Publication, Engineering Monograph 41. US
Printing Office, Denver Col.
13. FALVEY H. T. and ERVINE D. A. (1988) : " Aeration in jets and high velocity
flows ". Model - prototype correlation ofhydraulic structures Colorado Springs, ed.
P. H. Burgi, 25-55.
90
Subcripts
a air.
c critical flow.
e equilibrium.
inception.
m mixture.
u uniform flow.
w water.
91
27. HOUK I.E. (1927) : " New design features in Willwood diversion dam ".
Engineering News-Record 99 (17), 660-664.
28. KELLER R. J., LAI K. K. and WOOD I. R. (1974) : .. Developing region in
self-aerated flow ". Proc. ASCE, J. Hydraulics Division l 00 (4), 553-568; 100 (I I),
1729-I730; 101 (2), 319-320; 101 (9), 1278-I280; 102 (4), 529-530.
29. KELLER R. J. and RASTOGI A K. (1975) : " Prediction of flow development on
spillways ". Proc. ASCE, J. Hydraulics Division I 0 I (9), 1171-1184; I 02 (9),
I401-1404; 103 (6), 664.
30. KELLER R. J. and RASTOGI AK. (I977) : " Design chart of predicting critical
point on spillways". Proc. ASCE, J. Hydraulics Division 103 (12), 1417-1429;
104 (12), 1678.
31. KILLEN J.M. and ANDERSON A.G. (1969) : "A study of the air-entrained flow
in open channels ". XIII JAHR-Congress (Kyoto) 2, 339-347.
32. KoBus H. E. (1985) : " An introduction to air-water flows in hydraulics ".
Mittei/ung Nr. 61, Institut fiir Wasserbau, Universitat Stuttgart, Eigenverlag des
Instituts.
33. LAI K. K. (1968) : " A study of air entrainment in steep open channels ".
Conference on Hydraulics and Fluid Mechanics, The Institution of Engineers,
Australia, 41-44; 241-242.
34. LAKSHMANA RAO N. s., SEETHARAMIAH K. and GANGADHARIAH T. (1968) : "A
new electrical probe for measurement of air concentration in air-water flows ".
J. Institution of Engineers (India) 48 (11), 1677-1693.
35. LAKSHMANA RAO N. s., SEETHARAMIAH K. and GANGADHARAIAH T. (1970) :
" Characteristics of self-aerated flow". Proc. ASCE, J. Hydraulics Division 96 (2),
331-355; 96 (12), 2622-2627; 97 (12), 2077.
36. LAKSHMANA RAO N. s. and GANGADHARAIAH T. (1971) : " Self-aerated flow
characteristics in wall region ". Proc. ASCE, J. Hydraulics Division 97 (9),
1285-1303.
37. LAKSHMANA RAo N. S. and KOBUS H. E. (1975): "Characteristics of self-aerated
free-surface flows ". Water and wastewater current research and practise Nr. I 0,
Erich Schmidt-Verlag, Berlin-Bielefeld-Miinchen.
38. LANE E. W. (1936) : " Recent studies on flow conditions in steep chutes ".
Engineering News-Record 116 (I), 5-7.
39. LANE E.W. (1939) : " Entrainment of air in swiftly flowing water ". Civil
Engineering 9 (2), 89-91; 9 (6), 371.
40. LEVIN L. (1955) : " Quelques reflexions sur la mecanique de l'ecoulement des
melanges d'eau et d'air ". La Houi/le Blanche l l (8), 555-558.
41. LUDIN A (1928) Modellversuche fiir die Schussrinne des
Shannon-Kraftwerkes ". Der Bauingenieur 9 (11 ), J 79-184.
42. OKADA A, KUDO M. and FUKUHARA K. (1959) : " Field tests of high velocity
flow and its air context ». VIII JAHR-Congress Montreal, 1D, l-20.
43. RAJARATNAM N. (1962):" Energy loss in a short-smooth-steep chute". J. Central
Board of Irrigation and Power, 19 (9) 725-730.
92
44. SINNIGER R. 0. and HAGER W. H. ( 1989) : " Constructions Hydrauliques -
Ecoulements stationnaires ". Presses Polytechniques Romandes, Lausanne.
45. STEVENS J.C. (1938) : "Hydraulic knowledge". Engineering News-Record, 120,
236-238.
46. STRAUB L. G., KILLEN J. M. and LAMB 0. P. (1954) : " Velocity measurement of
air-water mixtures". Trans. ASCE 119, 207-220.
47. STRAUB L. G. and LAMB 0. P. (1953) : " Experimental studies of the air
entrainment in open channel flow ". V /AHR-Congress Minneapolis, 425-437.
48. STRAUB L. G. and LAMB 0. P. (1956) : " Studies of air entrainment in
open-channel flow ". Trans. ASCE 121, 30-44.
49. STRAUB L. G. and ANDERSON A.G. (1960) : "Experiments on self-aerated flow
in open channels". Trans. ASCE 125, 456-486.
50. Task Committee on Air Entrainment in Open Channels (1961) : " Aerated flows
in open channels ". Proc. ASCE, J. Hydraulics Division 87 (3), 73-86; 87 (6),
221-231.
51. THANDAVESWARA B. S. and LAKSHMANA RAo N. S. (1978) : " Developing zone
characteristics in aerated flows ". Proc. ASCE, J. Hydraulics Division 104 (3),
385-396; 105 (3), 279-281; 105 (11), 1451-1452.
52. VIPARELLI M. (1951) : " Premessa ad una ricerca sulle correnti rapide ".
L'Energia Elettrica 28 (1), 13-22.
53. VIPARELLI M. (1953): "The flow in a flume with 1 : l slope". V /AHR-Congress
Minneapolis, 415-423.
54. VIPARELLI M. (1954) : "Correnti rapide - risultati in canaletta a 450 ". L 'Energia
Elettrica 31(6),393-405.
55. VIPARELLI M. (1957):" Fast water flow in steep channels". VI /AHR Congress
Lisbon, 039, 1-12.
56. VIPARELLI M. (1958) : " Correnti rapide ". L'Energia Elettrica 35 (7), 633-649.
57. VoLKART P. ( 1980) : " The mechanism of air bubble entrainment in self-aerated
flow ". International J. Multiphase Flow 6, 411-423.
58. VoLKART P. U. (1982):" Self-aerated flow in steep, partially filled pipes". Proc.
ASCE, J. Hydraulics Division l 08 (9), l 029-1046.
59. WooD I. R. (1983) : " Uniform region of self-aerated flow ". Proc. ASCE,
J. Hydraulic Engineering I 09 (3), 447-461.
60. WooD I. R., ACKERS, P. and LOVELESS J. (1983) : " General method of critical
point on spillways ". Proc. ASCE, J. Hydraulic Engineering 109 (2), 308-312.
61. WOOD I. R. (1985) : "Air water flows". Keynote Address XX/ /AHR Congress
Melbourne, 18-29.
62. YEVDJEVICH V. and LEVIN L. (1953) : " Entrainment of air in flowing water and
technical problems connected with it". V JAHR Congress Minneapolis, 439-454.
93
4. AERATEURS D'EVACUATEURS DE CRUE
4.1. INTRODUCTION
Tous les evacuateurs de crue presentent des defauts de construction, le plus
souvent de faible importance, tels que irregularites aux joints de beton, ou decro-
chements dus a des tassements locaux (Fig. 36). De telles irregularites peuvent
provoquer une separation de l'ecoulement, associee a une reduction de pression
locale derriere l'irregularite [2, 38]. Les ecoulements sur Jes evacuateurs de crue ont
des vitesses de 20 a 40 ms- 1• Comme la reduction depression peut s'exprimer sous
la forme d'un multiple de la charge cinetique a l'approche, la pression dans la zone
de separation peut tomber au-dessous de la pression locale de vapeur Pv·
Le phenomene de vaporisation resultant d'une baisse de pression - au lieu
d'une augmentation de temperature jusqu'a la temperature d'ebullition - est appele
« cavitation ». Lorsque la pression augmente de nouveau au-dessus de la pression
de vapeur, Jes bulles de vapeur deviennent instables et eclatent, produisant ainsi des
micro-jets de vitesse elevee avec des pointes de pression tres fortes et de tres courte
duree. La cavitation en elle-meme n'est pas souvent dangereuse, a moins qu'elle ne
se produise pres des parois de I'ecoulement. Ces pointes depression, atteignant des
charges de IO 000 m de hauteur d'eau, peuvent alors endommager la surface par Jes
phenomenes de fatigue et d'impact [12]. Le beton ou I'acier qui a subi une cavitation
presente I'aspect d'un materiau soumis a une erosion. Les degiits par cavitation
resultent essentiellement d'un processus de fracturation dans des ecoulements d'eau
claire a partir de vitesses comprises entre 12 et 15 ms- 1, en fonction de la geometrie
de l'ecoulement.
On doit empecher par tous Jes moyens Jes degiits par cavitation, car ceux-ci
deteriorent progressivement l'ouvrage. On peut le faire en eloignant Jes zones de
cavitation des parois, en profilant Jes surfaces pour empecher Jes separations dans
J'ecouJement, OU en utiJisant des materiaux resistant a )a cavitation [39, 40).
Cependant, de tels procedes peuvent ne pas etre applicables aux evacuateurs de crue
ayant de grandes surfaces de contact.
L'adjonction d'air dans l'ecoulement a grande vitesse peut constituer un moyen
efficace et economique d'empecher Jes degiits par cavitation. La presence d'air pres
des parois de l'ecoulement agit comme un coussin permettant de reduire l'effet de
l'eclatement des bulles d'air. Cet effet resulte de la diminution de la vitesse sonique
de l'eau due a la presence d'air. Pour des vitesses d'ecoulement atteignant 35 ms- 1,
une teneur en air entre 6 et 8 % peut empecher l'erosion par cavitation [21].
a)
94
4. SPILLWAY AERATORS
4.1. INTRODUCTION
All spillways contain minor construction defects, such as irregularities at
concrete joints or changes due to local settlements (Fig. 36). Such irregularities may
cause separation of flow, associated with a local pressure reduction behind the
irregularity [2, 38]. For spillway flow, the velocities are typically in the range of 20
ms-I to 40 ms- 1• As the pressure reduction may be expressed as a multiple of the
approaching velocity head, the pressure in the separation zone may fall below the
local vapor pressure Pv·
Fig. 36
Local low pressure zones due to surface irregularities
and typical surface damage.
Zones de basse pression dues a des irregularites de surface
et degats de surface caracteristiques.
(· • ·) Separating streamline. (· • ·) Ligne de courant de separation.
95
Lorsque l'entrainement d'air nature! ne suffit pas a assurer la concentration
d'air necessaire au fond, on peut installer le long du coursier des dispositifs speciaux
d'entrainement d'air, appeles aerateurs de coursier.
Parmi Jes premiers rapports consacres aux aerateurs de coursier, on peut citer
Jes Russes (Galperin, Semenkov et autres) et Jes Bresiliens (Pinto). Eccher et
Siegenthaler [9] presenterent un compte rendu des rapports publies au cours des
annees 70 sur cette question. Des details sur la cavitation dans Jes ouvrages
hydrauliques furent fournis par Hamilton [14]. Les effets d'echelle furent examines
au Symposium d'Esslingen en 1984 (Marcano et Castillejo [17]; Pan et Shao [20];
Wood [43)). Michel [l 8] ainsi que Laali et Michel [16] ont analyse le mecanisme
d'entrainement d'air. L'attention fut attiree sur la pulsation dans la cavite et ses
caracteristiques physiques. En ce qui concerne l'entrainement d'air, on indiqua le
role important du nombre de Froude et du coefficient de cavitation. Des etudes sur
modeles furent effectuees par de Fazio et Wei [8], Wood [43] et Pinto et al. [22, 23,
24, 25, 26, 27], avec comparaison des resultats avec Jes observations sur les ouvrages
reels. Une attention particuliere fut portee aux dispositifs d'aeration du barrage de
Guri (Marcano et al. [17]; Castillejo et al. [3]; Zagustin et al. [46, 47)), du barrage
d'Alicura (Vernet et al. [35)) et du barrage d'Uribante (Coleman et al. [6]). Aksoy et
al. [I], Prusza et al. [28] et Vischer [37) examinerent les aspects pratiques de projet,
tandis que Wood [44) resuma les connaissances actuelles en matiere d'aerateurs de
coursier.
96
insufficient for the bottom air concentration required, special a1r entraining
structures called chute aerators must be provided along the chute.
Along the cavity downstream from the aerator, a highly turbulent spray-air
mixture exists. As the cavity pressure is subatmospheric, air is supplied by the
aeration system and entrained in the flow due to a pressure difference ~p between
the atmosphere and the cavity. Thus, the cavity air concentration at zone is ®
97
cavite de la zone Q) est done constante pour une valeur ~p au-dessous de la pression
atmospherique (Fig. 37). Dans la zone d'impact du jet (zone de transition entre la
zone Q) et la zone @), la pression au fond augmente nettement jusqu'a une valeur
maximale. Plus a l'aval, la pression en radier tend asymptotiquement vers la
profondeur de l'ecoulement, et la concentration d'air au fond diminue progressive-
ment par suite de depart d'air.
A partir d'etudes sur modeles et sur ouvrages reels en Russie et au Bresil,
Vischer et al. [36) et Volkart [39) ont propose trois types de dispositif d'entrainement
d'air : le deflecteur, le decrochement et la rainure. Le dernier type n'a pas ete retenu,
etant donne que les rainures sont sujettes a submersion, ce qui entraine une rupture
de l'entrainement d'air par suite de penetration d'eau a l'interieur des tuyaux
d'alimentation en air.
Un aerateur doit conduire a un entrainement d'air tres uniforme sur la largeur
du coursier et avec le moins de perturbation possible dans l'ecoulement sur le
coursier. Comme dispositif optimal d'entrainement d'air, on peut recommander une
combinaison du deflecteur et du decrochement. Des dispositifs d'alimentation en
air, tels que ceux representes sur la Fig. 38, ont ete proposes par Volkart et
Rutschmann [40). Ces dispositifs ne provoquent que de petites ondes transversales
et permettent une distribution d'air sur toute la section transversale du coursier.
Rutschmann [27), Rutschmann et Volkart [32] ont propose une methode pour
determiner l'ecoulement d'air dans un conduit de distribution (Fig. 38 b)). L'ecoule-
ment sur le coursier, a l'aval de l'aerateur, reste a peu pres plan.
Le fonctionnement hydraulique d'un aerateur de coursier peut etre decrit
comme suit. Une difference de pression ~p entre !'atmosphere et la cavite entraine
un ecoulement d'air Qa dans le dispositif d'alimentation en air. Le debit d'air depend
principalement de ~p et de la geometrie du dispositif d'alimentation en air. Le debit
Qa peut etre calcule par extension de !'equation de Bernoulli, tenant compte de la
somme des pertes de charge depuis !'atmosphere a travers le conduit d'alimentation
et le dispositif eventuel de distribution jusqu'a la cavite sous le jet.
L'entrainement d'air dans l'ecoulement sur le coursier depend principalement
de la difference de pression ~p dans la cavite, des caracteristiques du jet et de la
geometrie de l'aerateur. Dans ce qui suit, seul le dernier phenomene sera examine,
etant donne que le dispositif d'alimentation en air depend beaucoup des caracteris-
tiques geometriques du canal d'approche [29, 31).
98
constant at a value ~p below atmospheric pressure (Fig. 37). At the jet impact zone
(transition from zone ® to @)) the bottom pressure significantly increases to a
maximum value. Further downstream, the bottom pressure head tends
asymptotically to the flow depth, and the bottom air concentration decreases
gradually due to air detrainment.
Based on both model and prototype analyses in Russia and Brazil, Vischer et
al. [36] and Volkart [39] proposed three types of air entrainment devices, namely the
deflector, the offset and the groove. Since the latter are susceptible to submergence,
that is the breakdown of the air entrainment as water is flowing back into the air
supply conduit, grooves are excluded.
An aerator should entrain the air most uniformly over the width of chute and
with the least disturbance in the chute flow. The combination of deflector and offset
may be recommended as the optimum air entrainment device. Air supply systems,
such as shown in Fig. 38, were proposed by Volkart and Rutschmann [40]. These
involve only a small development of cross-waves and are particularly able to
distribute the air across the entire chute. Rutschmann [27] and Rutschmann and
Volkart [32] presented an approach for the determination of air flow in a distribution
duct as shown in Fig. 38 b). The chute flow downstream from this aerator remains
nearly plane.
The air entrainment in the chute flow, on the other hand, depends mainly on
cavity pressure difference ~p, the characteristics of the mixture jet and the aerator
geometry. In the following, only the latter phenomenon will be studied, as the air
supply supply system depends strongly on the entrance geometry [29, 31].
Fig. 39 shows schematically the flow at a chute aerator. The chute axis is
Fig. 37
Schematic flow in the vicinity of aerator.
Representation schematique d'un ecoulement a proximite d'un aerateur.
(... ) Bottom pressure head curve. (. ..) Courbe de la hauteur piezometrique en radier.
(For details see text.) (Se reporter au texte pour /es details.)
99
•·>·,:::: . ·•·•••:ta·.·.·.·.Eit·u ,,,,.
100
e
a)
Fig. 39
Schematic side view at chute aerator.
Vue laterale schematique d'un aerateur de coursier.
a) Detail. a) Detail.
b) Overall view. b) Vue generale.
assumed straight both in the longitudinal section and in plan view. h and V are the
approaching flow depth and average velocity, 8 the slope of chute, a the deflector
angle, t, and ts the height of deflector and offset (« step ») and Lj the length of jet
from aerator to the point of maximum bottom pressure (Fig. 37).
Herein, IF
= V (gh)- 112 is the approaching Froude number and
IE = V (~p/p)- the cavity Euler number. Rutschmann and Hager [33, 44] were able
2 1
101
IEmin = IE (~ = 0). La derniere expression correspond a la pression relative de la
cavite pour laquelle l'entrainement d'air disparait. Emin peut etre ajuste par un
ensemble limite de donnees :
1
10- 3 IE min= - -(tg a) 1•15 exp [l,15 (tg 8)2] + _!_T 2 (4.3)
2,3 3 s
ou T, = t/h. Pour une geometrie donnee d'aerateur, on peut calculer IEmin et I'effet
de la sous-pression lip de la cavite depend exclusivement de ~max-
Suivant que le coursier a l'amont de l'aerateur est court (comme c'est le cas dans
Jes laboratoires d'hydraulique) ou long (comme sur Jes ouvrages reels), on peut faire
une distinction entre l'ecoulement d'approche en cours d'evolution et l'ecoulement
d'approche etabli. Dans le dernier cas, l'ecoulement graduellement varie (aere)
domine et on peut appliquer ce qui suit.
A partir des etudes faites par Pinto et al. [22, 23], Minor [ 19], Pinto [27], et des
resultats experimentaux obtenus par Rutschmann [30, 31], le coefficient maximal
d'entrainement d'air ~max peut etre relie a la longueur relative du jet \ = L/h sous
la forme suivante [33, 34] :
~max = 0,030 (Ai - 5) pour IF > 6 (4.4)
Ce resultat est interessant dans la mesure OU le taux maximal d'entrainement
d'air depend lineairement de la longueur de la surface de separation entre l'eau et
!'air. L'entrainement d'air depuis un aerateur est done un phenomene avec domi-
nance de cisaillement, ainsi que cela peut etre demontre par d'autres analyses
(Fig. 40).
Dans le cas d'un ecoulement d'approche etabli, la longueur relative du
jet A,i = L/h pour un aerateur en forme de rampe peut etre calculee comme suit [33] :
:~s": [1 (1 + 2~~;;2 8)
112
A,i = + ] (4.5)
a
(4.7)
a
102
IEmin = IE (~ = 0) as the relative cavity pressure at which the air entrainment
vanishes. Emin was adjusted by a limited set of data as :
1
10- 3 IE min = - -(tg a) 115 exp [l.15 (tg 8)2) + ! T s2 (4.3)
2.3 3
where Ts= t/h. For any given aerator geometry, IEmin may be computed, and the
effect of cavity subpressure ~p depends exclusively on the maximum air entrainment
rate ~max-
Depending on whether the aerator approaching chute is short (as typically in
hydraulic labs) or long (as in prototypes), a distinction between so-called developing
and developed approaching flow may be made. In the latter case, gradually varied
(aerated) flow prevails and the following may be applied.
Based on considerations by Pinto et al. [22, 23), Minor [19), Pinto [27) and
experimental data by Rutschmann [30, 31), the maximum air entrainment coefficient
~max may be related to the relative length of jet, Ai = L/h as [33, 34] :
For developed approaching flow, the relative length of jet Ai = L/h for ramp
aerators may be computed as [33) :
A_ <i·IF
J - cos e
2
[i + (i + 2T·cos8)
(aIF)2
112
] (4.5)
a (4.7)
a
Fig. 40
Bottom aerator with shear-dominated air-water interface.
Aerateur de fond avec inteiface de cisaillement air-eau.
103
ou Tr= t/h est la hauteur de la rampe et Tgh est la fonction tangente hyperbolique.
Le calcul du taux d'entrainement d'air devient ainsi direct si Jes conditions suivantes
sont satisfaites : T < I, tga < 0, 15 et 6 < IF < 12. Le coursier ne devra pas
egalement avoir une pente transversale importante, son axe sera rectiligne, et un
ecoulement a peu pres bi-dimensionnel devra s'etre etabli. A ce jour, aucune etude
experimentale systematique n'a ete effectuee pour verifier le present modele
mathematique. Rutschmann et Hager [34] ont pu verifier la presente methode a partir
de resultats obtenus sur des ouvrages reels.
Une autre methode d'etude, faisant intervenir le niveau de turbulence sur la
rampe, !'angle de sortie du jet et Jes pertes a travers Jes orifices d'aeration, a ete
proposee par Glazov [13].
Exemple 4.1.
Soit un coursier de pente de radier 8 = 28°, avec un ecoulement de profondeur
h = 1,2 m et de vitesse V = 27 ms- 1 a l'approche. Que! est le taux maximal
d'entrainement d'air Pmax pour un aerateur de pente a= 4°, de hauteur tr= 0,2 m et
de hauteur de decrochement ts= 0,2 m?
Le nombre de Froude de l'ecoulement d'eau pure a l'approche est
IF= 27/(9,81 x 1,2) 112 = 7,9 et l'aerateur peut etre caracterise geometriquement
par a = 0,070, T = 0,333 et Tr = 0, 167. On a done a = 0,983 x 0,070 = 0,069
d'apres !'equation (4.7). De plus, \ = 13,3 d'apres !'equation (4.5) et, done,
Pmax = 0,25. On a done pour l'entrainement maximal d'air par unite de Jargeur
qa = 0,25 x 27 x 1,2 = 8,1 m3 s- 1•
Exemple 4.2.
Que! est l'effet d'une difference depression ~p/(pg) = 0,3 m de hauteur d'eau
sur l'entrainement d'air?
Le nombre d'Euler est egal a IE = (V2 /g)/(~p/pg) = 247,7. En outre, avec
a = 4°, 8 = 28° et T, = 0,167, on obtient : IEmin = 65,2 (eq. 4.3). II en resulte :
~IE = 247,7 - 65,2 = 182,5 et PIPmax = 0,449. Le coefficient d'entrainement d'air
est done (eq. 4.2) : p = 0,449 x 0,25 = 0,112.
D'autres recommandations pour le projet d'aerateur ont ete donnees par
Rutschmann et Hager [34]. La pente de l'aerateur devrait etre comprise entre 5° et
10°. De plus, on a demontre que l'efficacite optimale de l'aerateur etait atteinte pour
1 1
W~max a/a
0.5 0.5
104
where T, = t,/h is the height of ramp and « Tgh » the hyberbolic tangent function.
Computation of the air entrainment rate thus becomes straightforward if the
following conditions are satisfied : T < 1, tga < 0.15 and 6 < IF < 12. Also, the
chute should have no significant transverse slope, its axis is straight and nearly
two-dimensional flow should have established. Actually, no systematic experimental
studies were conducted to verify the present computational model. Rutschmann and
Hager [34] were able to verify the present approach by prototype data.
An alternative design procedure involving the turbulence level at the ramp, the
exit angle of jet and the losses through the air vent was proposed by Glazov [13].
Example 4.1.
Given a chute with approach flow depth h = 1.2 m, velocity V = 27 ms - 1 and
bottom slope 8 = 28°. What is the maximum air entrainment rate Pmax for an aerator
of slope a= 4°, height t,= 0.2 m and height of step t, = 0.2 m?
The approach Froude number is IF = 27 /(9.81 x l.2) 112 = 7.9 and the aerator
geometry may be described by a = 0.070, T = 0.333 and T, = 0.167. Thus
a = 0.983 x 0.070 = 0.069 according to Eq. (4.7). Further, \ = 13.3 according to
Eq. (4.5) and thus Pmax = 0.25. The maximum air entrainment per unit width is thus
qa = 0.25 X 27 x 1.2 = 8.1 m 3 s- 1•
Example 4.2.
What is the effect of a pressure difference ~p/(pg) = 0.3 m water column on the
air entrainment?
The Euler number obtains : IE = (V2 /g)/(~p/pg) = 247.7. Further, with
a = 4°, 8 = 28° and T, = 0.167, one obtains : IEmin = 65.2 from Eq. (4.3). As a
result, ~IE = 247.7 - 65.2 = 182.5 and PIPmax = 0.449. The air entrainment
coefficient thus is from Eq. (4.2) : p = 0.449 x 0.25 = 0.112.
Additional guidelines for aerator design were given by Rutschmann and
Hager [34]. Regarding the slope of aerator, values between 5° and I 0° should be
adopted. It was further shown that the optimum aerator efficiency occurs for
Fig. 41
Graphical Display.
Representation graphique.
a) Of Eq. (4.2). a) De /'equation (4.2).
b) Of Eq. (4.7). b) De /'equation (4. 7).
105
~opt = (1/3) ~max· Cette relation permet d'estimer la surface de la section des conduits
d'alimentation en air. Rutschmann et Hager [34] ont egalement etabli une relation
entre la hauteur optimale de l'aerateur et le nombre de Froude a l'entree, et Jes pentes
du coursier et de l'aerateur. Avec ces indications et une verification de projets
d'aerateurs existants [45], le projet d'aerateur standard ne doit pas poser de proble-
mes.
c* = -~- ( 4.10)
1+ ~
J_ J- Ce
I -- C (4.11)
c= - '
1 _1--Ce
I - C*
a la relation suivante :
x* = - [I - c+ Inc] (4.12)
106
Popt = (1/3) Pmax· This relation provides an estimate for the area of air supply
conduits. Rutschmann and Hager [34) also related the optimum height of aerator to
the approach Froude number, and the slopes of chute and aerator. With these
indications, and a check on existing aerator designs [45], the design of the standard
aerator becomes straightforward.
Based on Wood's [43) approach, Chanson [5] assumed that beyond the jet
impact point, that is in the gradually varied aerated flow zone (Fig. 37), the rate of
air entrainment is constant and equal to the equilibrium rate Ce. Further, the rate of
air escape was assumed proportional to the local air concentration C = C (x).
Therefore, the local change of air flow qa is with u, as the bubble rise velocity
dq.
_a= - -C)
(Ce - Ur COS
e
H (4.8)
dx
(4.10)
I_ I - Ce
1-C (4.11)
x* = - [I - c + Inc] (4.12)
where X = (u, cos8/qw) x. The bubble rise velocity was found as u, = 0.16 ms- 1
for scale models and 0.40 ms- 1 for prototypes. The difference in u, may be explained
107
difference de u, peut s'expliquer par la difference de diametre db des bulles d'air [7].
En general, on peut admettre que la vitesse d'ascension des bulles d'air est constante.
A I'aval du point d'impact du jet, Jes bulles d'air soot redistribuees et tendent
asymptotiquement vers la concentration d'air a l'equilibre, telle qu'elle est definie
par )'equation (3.9). Une fois u, defini, le profil de la concentration d'air C (x) dans
la zone de transition peut etre calcule suivant )'equation (4.12). De plus, en suppo-
sant un profil de teneur en air C (y) defini suivant )'equation (3.9), une teneur
moyenne minimale cmin = 30 % est necessaire pour assurer une teneur en air de 5 %
a 10 % pres du fond. II en resulte que Jes aerateurs de fond soot absolument
necessaires pour Jes coursiers de pente 8 < 20°, comme deja vu au chapitre 3, a
condition que l'ecoulement soit presque uniformement aere. Pour Jes evacuateurs OU
8 est superieur a 30°, avec un ecoulement aere presque uniforme, aucun aerateur ne
sera necessaire puisque l'entrainement d'air nature! est suffisant pour le proteger le
fond contre l'erosion par cavitation.
Exemple 4.3
Considerons I'exemple 4.2. Quel est le profil longitudinal de la concentration
moyenne d'air C (x) si l'ecoulement a l'amont de l'aerateur ne contient pas d'air et
si la vitesse d'ascension des bulles d'air est u, = 0,40 ms- 1 ?
Avec ~ = 0,112, la concentration d'air initiale correspondante est C* = 0,101
d'apres )'equation (4.10) si l'ecoulement d'approche n'est pas aere. L'equation (3.11)
donne pour la concentration d'air a l'equilibre Ce = 0,259. Le Tableau ci-dessous
indique !'evolution de la concentration moyenne d'air C dans la section transversale.
On constate que la concentration d'air Ce est atteinte asymptotiquement au bout de
I 00 m environ.
x [m] 0 10 20 40 60 100
108
by the various sizes of bubble diameter d 0 [7]. Normally, the bubble rise velocity is
assumed constant.
Downstream from the jet impact point, the air bubbles are redistributed and
tend asymptotically to the equilibrium air concentration as given in Eq. (3.9). The
transition concentration profile C (x) may be computed with Eq. (4.12) once u, is
determined. Further, upon assuming an air concentration profile C (y) according to
Eq. (3.9), a minimum average concentration Cmin = 30 % is needed to secure a near
bottom air concentration of 5 % to I 0 %. This is to say that bottom aerators are
definitely needed for chutes with slopes 8 < 20° as already discussed in chapter 3
provided the flow is almost uniformly aerated. For spillways where 8 > 30° with
almost uniform aerated flow, no aerator will be required since the natural air
entrainment is sufficient to protect the bottom from cavitational erosion.
Example 4.3
Consider example 4.2. What is the longitudinal profile of mean air
concentration C (x) if no air is contained upstream from the aerator, and the air
bubble rise velocity is u, = 0.40 ms - i?
With r) = 0.112, the corresponding initial air concentration is C* = 0.1 OI
according to Eq. (4.10) if the approaching flow is not aerated. From Eq. (3.11) the
equilibrium air concentration obtains Ce = 0.259. The Table below gives the
development of cross-sectional mean air concentration C. The asymptotic air
concentration Ce is reached within 100 m, roughly.
x [m] 0 JO 20 40 60 JOO
109
,. 152
(mJ
Fig. 42
Longitudinal chute profile with adaptation
to topography (Rutschmann, 1988) [30, 31].
Pro/ii en long d'un coursier s'adaptant a la topographie
(d'apres Rutschmann, 1988) [30, 31]
Exemple 4.4
La Fig. 42 donne un exemple OU )'emplacement des aerateurs a ete determine
uniquement par rapport a la topographie du coursier. Dans cet exemple, un plus
petit nombre d'aerateurs aurait suffi pour la protection du coursier, mais cela aurait
110
26.3°
~
oy
-+----------------~~----~- ---
Fig. 43
Aerator for concave bottom geometry.
Aerateur pour une forme concave de radier.
- Based on a backwater curve for pure water flow along the entire chute, the
cavitation number :
Example 4.4
Fig. 42 shows an example in which the location of aerators was chosen only
relative to the topography of chute. In this example, less aerators would have been
sufficient for chute protection, but this would have required relatively costly
111
necessite des ouyrages de transition relativement couteux. L'aerateur@a une forme
tres particuliere, etant situe dans une auge, et une submersion pouvant se produire
pour un deflecteur trop petit. Dans ce cas, ii y aurait penetration d'eau dans le
dispositif d'alimentation en air et coupure du circuit d'air. D'autre part, le detlecteur
ne doit pas avoir une pente trop raide, ni etre trop long, car ii pourrait caviter a son
extremite aval; l'ecoulement pourrait egalement etre rejete trop loin du coursier et
des murs de grande hauteur seraient necessaires. La Fig. 43 donne une solution pour
l'exemple considere. Elle consiste en un deflecteur courbe ressemblant a une cuillere
de dissipation.
L'aeration en radier est tres sensible a un exces d'aeration conduisant a des murs
lateraux du coursier de hauteur excessive et a une augmentation de la vitesse due a
la diminution du frottement sur Jes parois (Fig. 34 a). Le bassin de dissipation
d'energie peut se comporter differemment de ce qui a ete prevu, par suite d'une
insuffisance d'eau a l'aval, ou meme de la chasse du ressaut. En conclusion, on peut
indiquer que le projet d'aerateurs doit comprendre des etudes sur modele a une
echelle appropriee.
Ce qui precede concerne exclusivement Jes canaux rectilignes dont la pente
transversale du radier est nulle. Pour Jes canaux presentant une courbe, le projet des
aerateurs est beaucoup plus complique et des effets nuisibles causes par des ondes
transversales peuvent se produire. Actuellement, la plupart de tels organes soot
etudies sur modeles reduits. Une importante contribution a ete presentee par Wei et
de Fazio [42] qui ont resolu Jes equations regissant l'ecoulement potentiel par la
methode des elements finis. Les projets futurs pourraient s'appuyer sur cette
approche lorsque Jes conditions aux limites soot correctement prises en compte. Le
modele reduit restera le moyen le plus commode pour etudier Jes ecoulements sur
Jes coursiers, a condition que l'echelle du modele soit bien choisie pour permettre
une transposition acceptable des resultats a l'ouvrage reel.
112
trans1t10n structures. Aerator @ has a quite specific shape as it is located in a
trough and submergence might occur for a too small deflector. Then, water would
run back into the air supply system and cut the air stream. On the other hand. the
deflector must not be too steep and long as it could cavitate at its downstream
extremity. Also, the flow could be deflected too far from the chute and impose high
chute walls. Fig. 43 shows a solution as proposed for the example considered. It
consists of a curved deflector and resembles a flip bucket.
The previous discussion was limited to straight channels with zero transverse
bottom slope. For curved channels, the aerator design is much more involved and
adverse effects from cross-waves may occur. Actually, most of such elements are
analysed by scale models. An outstanding contribution was forwarded by Wei and
de Fazio [42], who solved the governing equations for potential flow numerically by
the finite element method. Future designs could be based on this approach when
correctly incorporating the boundary conditions. The scale model will remain the
most convenient means to design chute flows provided its scale permits a reasonable
up-scaling to the prototype.
l 13
h [m] profondeur de l'ecoulement.
Li [m] longueur du jet.
\ [-] longueur relative du jet.
p/(pg) [m] charge piezometrique.
Q [m3s-1] debit.
q [m2s-1] debit unitaire.
p [kgm- 3] densite.
(J [-] coefficient de cavitation.
(Ji [-] coefficient de debut de cavitation.
T [-] hauteur relative de l'aerateur.
T, [-] hauteur relative du deflecteur.
T, [-] hauteur relative du decrochement.
t, [m] hauteur du deflecteur.
ts [m] hauteur du decrochement.
u, [ms- 1] vitesse d'ascension des bulles d'air.
v [ms- 1] vitesse.
x [-] coordonnee normalisee.
x* [-] coordonnee longitudinale normalisee.
Indices
a air.
e equilibre.
max maximum.
min minimum.
v vapeur.
w eau.
4.6. REFERENCES
114
h [m] flow depth.
Lj [m] jet length.
A,j [-] normalised jet length.
p/(pg) [m] pressure head.
Q [m3s .. 1] discharge.
q [m2s-1] unit discharge.
p [kgm- 3] density.
(J [-] cavitation number.
CT; [-] incipient cavitation number.
T [-] relative aerator height.
T, [-] relative deflector height.
T, [-] relative offset height.
t, [m] deflector height.
ts [m] offset height.
u, [ms- 1] bubble rise velocity.
v [ms- 1] velocity.
x [-] normalised coordinate.
x* [-] normalised length coordinate.
Subscripts
a air.
e equilibrium.
max maximum.
mm mm1mum.
v vapor.
w water.
115
12. FALVEY H. T (1990) : "Cavitation in chutes and spillways". Water Resources
Technical Publication. US Printing Office, Engineering Monograph 42, US Dept.
of Interior, Bureau of Reclamation, Denver, Col.
13. GLAZOV A. I. ( 1985) : " Calculation of the air-capturing ability of a flow behind
an aerator ledge ". Hydrotechnical Construction 18 (11), 554-558.
14. HAMILTON W. S. (1983) : " Preventing cavitation damage to hydraulic
structures". Water Power 35 (11), 40-43; 35 (12), 48-53; 36 (1), 42-45.
15. KOSCHITZKY H.P. and KOBUS H. (1988) : " Hydraulics and design of spillway
aerators for cavitation prevention in high speed flows ". International
Symposium on Hydraulics for High Dams Beijing, 724-733.
16. LAALI A. R. and MICHEL J.M. (1984) : "Air entrainment in ventilated cavities :
case of a fully developed half-cavity. ". J. Fluids Engineering 106 (9), 327-335.
17. MARCANO A. and CASTILLEJO N. (1984) : " Model-prototype comparison of
aeration devices of Guri dam spillway ". Symp. Scale Effects in Modelling
Hydraulic Structures (Esslingen) 4.6, 1-5.
18. MICHEL J.M. (1984) : "Some features of water flows with ventilated cavities".
J. Fluids Engineering I 06 (9), 319-326.
19. MINOR H.-E. (1984) Erfahrungen mit Schussrinnenbeliiftung ".
Wasserwirtschaft 77 (6), 292-295.
20. PANS. and SHAO Y. (1984) : "Scale effects in modelling air demand by a ramp
slot". Symp. on Scale Effects in Modelling Hydraulic Structures (Esslingen), 4.7,
1-5.
21. PETERKA A. J. ( 1955) : " The effect of entrained air on cavitation pitting ".
V. !AHR Congress Minnesota, 507-518.
22. PINTO N. L. de S. and NEIDERT S. H. (1982):" Model - prototype conformity in
aerated spillway flow ". Hydraulic Modelling of Civil Engineering Structures
Coventry (England), 273-284.
23. PINTO N. L. de S., NEIDERT S. H. and OTA J. J. (1982): "Aeration at high velocity
flows ". Water Power and Dam Construction 33 (2) : 34-44.
24. PINTO N. L. de S. and NEIDERT S. H. (1983) : " Evaluation entrained air flow
through aerators ". Water Power and Dam Construction 34 (8), 40-42.
25. PINTO N. L. de S. (1984) : " Model evaluation of aerators in shooting flow".
Symp. on Scale Effects in Modelling Hydraulic Structures 4.2, 1-6.
26. PINTO N. L. de S. (1986):" Basic hydraulics of shooting flows over aerators".
ASCE Specialty Conf. Advancements in Aerodynamics, Fluid Mechanics and
Hydraulics I 007-1017.
27. PINTO N. L. de S. (1989) : " Designing aerators for high velocity flow". Water
Power & Dam Construction 40 (7), 44-48.
28. PRUSZA Z. V., MANTELLINI T. P. and SEMENKOV v. ( 1983) : " Remedial measures
against spillway cavitation ". XX !AHR Congress (Moscow) 3, 468-476.
29. RUTSCHMANN P. (1987) Die transversale Druckverteilung unter
Sprungstrahlen von Schussrinnenbeliiftern - Folgen filr den Lufteintrag ".
Wasserwirtschaft 77 (5), 219-223.
30. RUTSCHMANN P. (1988a) : "Calculation and optimum shape of spillway chute
116
aerators ". Model - Prototype Correlation of Hydraulic Structures Colorado
Springs (Col.), 118-127.
31. RuTSCHMANN P. ( l 988b) : " Beliiftung von Schu~rinnen - Ausfilhrung und
Bemessung ". Internat. Symposium Erosion, Abrasion und Kavitation.
Mitteilung No. 99, 149-169, Versuchsanstalt filr Wasserbau, Hydrologie und
Glaziologie, ETH-Zurich, ed. D. Vischer, Zurich.
32. RUTSCHMANN P. and VOLKART P. (1988) : " Spillway chute aeration ". Water
Power and Dam Construction 40 ( 1), l 0-15.
33. RUTSCHMANN P. and HAGER w. H. (1990a) : " Air entrainment by spillway
aerators". J. Hydraulic Engineering ASCE, 116 (6), 765-782; 117 (4), 545.
34. RUTSCHMANN P. and HAGER w. H. (1990b) : " Design and performance of
spillway chute aerators ". Water Power and Dam Construction, 42 (1), 36-42.
35. VERNET G. F., ANGELACCIO C. M. and CHIVIDINI M. F. (1988)
" Model-prototype comparison in the Alicura chute spillway air system "
Model-Prototype Correlation of Hydraulic Structures Colorado Springs (Col.)
110-117.
36. V1sCHER D., VoLKART P. and SJEGENTHALER A. (1982) : " Hydraulic modelling
of air slots in open chute spillways ". Hydraulic Modelling of Civil Engineering
Structures Coventry (England), 239-252.
37. VISCHER D. ( 1985) : " Die Schussrinnenbeliiftung als Ma~nahme gegen
Kavitationserosion ". Oesterr. Wasserwirtschaft 37 (3/4), 117-123.
38. VISCHER D. (1987) : " Kavitation an Schussrinnen ". Wasserwirtschaft 77 (6),
288-291.
39. VOLKART P. (1983) : " Air slots for flow aeration ". Mitteilung No. 66,
Versuchsanstalt filr Wasserbau, Hydrologie und Glaziologie, Swiss Federal
Institute of Technology, Zurich, ed. D. Vischer, Zurich.
40. VoLKART P. and RuTSCHMANN P. (1984):" Air entrainment devices". Mitteilung
No. 72, Versuchsanstalt filr Wasserbau, Hydrologie und Glaziologie, Swiss
Federal Institute of Technology, Zurich, ed. D. Vischer, Zurich.
41. VOLKART P. and RUTSCHMANN P. (1986) : " Aerators on spillway chutes :
fundamentals and applications ". Advancements in Aerodynamics, Fluid
Mechanics and Hydraulics Minneapolis (Minnesota), 15 pages.
42. WEI C. Y. and DE FAZIO F. G. ( 1982) : " Simulation of free jet trajectories for the
design of aeration devices on hydraulic structures ". Finite Elements in Water
Resources Proc. IV Int. Conference, Hannover. Springer, Wien-Berlin.
43. WooD I. R. (1984) : " Air entrainment in high speed flows ". Symp. on Scale
Effects on Modelling Hydraulic Structures (Esslingen), 4.1, 1-7.
44. WOOD I. R. (1988) : " Aerators - the interaction of nappe and duct air
entrainment ". Int. Symp. on Hydraulics for High Dams (Beijing) 611-618.
45. WooD I. R. (1991) : "Air entrainment in free-surface flows". JAHR Hydraulic
Structures and Design Manual, 4. A. A. Balkema : Rotterdam/Brookfield.
46. ZAGUSTIN K. and CASTILLEJO N. (1983) : " Model-prototype correlation for flow
aeration in the Guri dam spillway ". XX JAHR-Congress (Moscow) 3, 443-452.
47. ZAGUSTIN K., MANTELLINI T. and CASTILLEJO N. (1982) : "Some experience on
the relationship between a model and prototype for flow aeration in spillways".
Hydraulic Modelling of Civil Engineering Structures Coventry (England), 285-295.
117
Imprimerie de Montligeon
61400 La Chapelle Montligeon
Depot legal : janvier 1992
No 15833
ISSN 0534-8293
Couverture : Olivier Magna
Copyright © ICOLD - CIGB
_______________________________________________________________
International Commission on Large Dams
Commission Internationale des Grands Barrages
151 Bd Haussmann -PARIS –75008