XT1B 160 TMD 160-1600 4p F F InN=100%


XT1B 160 TMD 160-1600 4p F F InN=100%

Informations générales
Extension du type de produit XT1B 160 TMD 160-1600 4p F F InN=100%

Code de produit 1SDA066821R1

EAN 8015644007287

Description courte XT1B 160 TMD 160-1600 4p F F InN=100%

DISJONCTEUR TMAX XT1B 160 FIXE TETRAPOLAIRE AVEC PRISES AVANT ET


Description longue
DECLANCHEURS THERMOMAGNETIQUES TMD R 160-1600 A NEUTRE = FASES

Ordering
EAN 8015644007287

Quantité minimum 1 pièce

Nombre des douanes tarif 85362090

Dimensions
Product Net Width 101.6 mm

Product Net Height 130 mm

Product Net Depth / 70 mm


Length

Poids net 1,381 kg


XT1B 160 TMD 160-1600 4p F F InN=100% 2

Container Information
Niveau de l'unité 1 pièce
d'emballage 1

Package Level 1 Width 128 mm

Package Level 1 Height 135 mm

Package Level 1 Depth / 143 mm


Length

Package Level 1 Gross 1,454 kg


Weight

Package Level 1 EAN 8015644007287

Additional Information
Circuit Breaker Type to be Power Distribution
Associated

Current Type AC/DC

Electrical Durability 120 cycles per hour


8000 cycle

Durabilite mecanique Nr. Operations 240 cycles per hour


Nr. Operations 25000 cycle

Nombre de pôles 4

Opening Time CB with SOR 15 ms


CB with UVR 15 ms

Quantité 1 pièce

Power Loss at Rated Operating Conditions per Pole 15 W

Product Main Type SACE Tmax XT

Nom du produit Moulded Case Circuit Breaker

Type de produit CB

Rated Current (I n ) 160 A

Fréquence assignée (f) 50 / 60 Hz

Rated Voltage (U r ) 690 V

Tension assignée de 8 kV
tenue aux chocs (U imp )

Courant assigné 1600 A


instantané de réglage de
court-circuit (I i )

Tension assignée d’ 800 V


isolement (U i )

Tension assigné d’emploi 690 V AC


500 V DC

Pourvoir assigné de (220 V AC) 25 kA


coupure de service en (230 V AC) 25 kA
court-circuit (I cs ) (240 V AC) 25 kA
(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 11.25 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA

Pouvoir assigné de (220 V AC) 25 kA


coupure ultime en court- (230 V AC) 25 kA
XT1B 160 TMD 160-1600 4p F F InN=100% 3

circuit (I cu ) (240 V AC) 25 kA


(380 V AC) 18 kA
(415 V AC) 18 kA
(440 V AC) 15 kA
(500 V AC) 8 kA
(525 V AC) 6 kA
(690 V AC) 3 kA
(250 V DC) 2 Poles in Series 18 kA
(500 V DC) 3 Poles in Series 18 kA

Courant assigné 160 A


ininterromptu (I u )

Release Type TM

Setting Range 112...160 A

Normes et standards IEC

Sub-type XT1

Terminal Connection Type Fixed Circuit-Breakers


Front

Version F

Certificates and Declarations (Document Number)


Data Sheet, Technical 1SDC210033D0204
Information

Declaration of Conformity 9AKK106713A5532


- CE

Environmental Information 1SDL000190R0001

GL Certificate 1SDL000163R0103

Instructions and Manuals 1SDH000719R0001

LR Certificate 1SDL000163R0100

Classifications
ETIM 4 EC000228 - Power circuit-breaker for trafo/generator/installation prot.

ETIM 5 EC000228 - Power circuit-breaker for trafo/generator/installation prot.

ETIM 6 EC000228 - disjoncteur pour transformateur, générateur et protection


d'installation

ETIM 7 EC000228 - Power circuit-breaker for trafo/generator/installation protection

Object Classification Code Q

UNSPSC 39120000

WEEE Category 5. Small Equipment (No External Dimension More Than 50 cm)

Catégories

Produits basse tension  → Disjoncteurs de puissance  → Disjoncteurs Boîtier Moulé  → Tmax XT


XT1B 160 TMD 160-1600 4p F F InN=100% 4