Series :
DS3 - *
Symbol Symbol
Voltage Model Voltage Model
pcs kg
Accessories Description per per Order Coder ( 1 Box )
box box
Black CN KA132000B9-100
Standard
Connector
Grey CN KA132000A9-100
Poles : 2 + 100 2.5
PG9 Bipolar LED 24 VDC
Overvoltage Protection CN KA132V54T9-100
Transparent Housing
12 V DU C22-D12K1/10
24 V DU C22-D24K1/10
DC Coil 1 0.5
110 V DU C22-D110K1/10
220 V DU C22-D220K1/10
24 V - 50 Hz DU C20.6 - A24K1/10
AC Coil 110 V - 50 Hz / 120 V - 60 Hz 1 0.35 DU C20.6 - A110K1/10
230 V - 50 Hz / 240 V - 60 Hz DU C20.6 - A230K1/10
DS3 : Pmax. = 350 bar, Port T : Pmax. = 210 bar ( DC ) / 160 bar ( AC ), Qmax. = 100 l/min ( DC ) / 90 I/min ( AC )
Hand Valves
Lever Actuated Control Valves
NG 6 / Cetop 3
Series :
DSH3 - *
Ordering Code :
DU DSH3-S1/10N
DU DSH3-S2/10N
DU DSH3-TA002/10N
2.1 kg
DU DSH3-SK1/10N
DU DSH3-SK2/10N
DU DSH3-SK3/10N
Locking Type
DU DSH3-SK4/10N
DU DSH3-TAK/10N
DU DSH3-TAK002/10N
Specification :
Maximum Flow : From P Port To A - B - T 75 l/min
Working Temperature : - 20 oC To + 70 oC
Working Pressure : Port P - A - B, 350 bar
: Port T, 320 bar
Series :
DS5 - *
Symbol Symbol
Voltage Model Voltage Model
pcs kg
Accessories Description per per Order Coder ( 1 Box )
box box
12 V DU C31-D12K1/10
24 V DU C31-D24K1/10
DC Coil 1 0.5
110 V DU C31-D110K1/10
220 V DU C31-D220K1/10
24 V - 50 Hz DU C25.4-A24K1/10
AC Coil 110 V - 50 Hz / 120 V - 60 Hz 1 0.35 DU C25.4-A110K1/10
230 V - 50 Hz / 240 V - 60 Hz DU C25.4-A230K1/10
DS3 : Pmax. = 350 bar, Port T : Pmax. = 210 bar ( DC ) / 160 bar ( AC ), Qmax. = 100 l/min ( DC ) / 90 I/min ( AC )
Hand Valves
Directional Valve Lever Actuated
NG10 / Cetop 5
Series :
DSH5-S*/10, DSH5-*TA*/10
Ordering Code :
DU DSH5-S1/10N
DU DSH5-S2/10N
DU DSH5-TA002/10N
4.2 kg
DU DSH5-SK1/10N
DU DSH5-SK2/10N
DU DSH5-SK3/10N
Locking Type
DU DSH5-SK4/10N
DU DSH5-TAK/10N
DU DSH5-TAK002/10N
Specification :
Maximum Flow : From P Port To A - B - T 120 l/min
Working Temperature : - 20 oC To + 70 oC
Working Pressure : Port P - A - B, 350 bar
: Port T, 320 bar
Series :
CE4, DS07, CE5, DSO10
Symbol NG 10 NG 16 NG 25 NG 32
DU CE4- ①/E/43 DU DS07- ①/10 NEE DU CE5- ①/E/34 DU DS10- ①/10 NEE
① ① ① ①
3)
S1 S1 S1 S13)
S2 S23) S2 S23)
S3 S33) S3 S33)
S4 S43) S4 S43)
S5 - S5 -
3)
S6 S6 S6 -
S7 S73) S7 -
S8 S83) S8 -
3)
S9 S9 S9 -
S18 - S18 -
- S20 - -
- S21 - -
- SA2 - SA2
- SA3 - SA3
- SA4 - SA4
- SB2 - SB2
- SB3 - SB3
- SB4 - SB4
TA TA3) TA TA3)
TA002 TA023) TA002 TA023)
23TC TA23 23TC -
Symbol NG 10 NG 16 NG 25 NG 32
DU CE4- ①/E/43 DU DS07- ①/10 NEE DU CES- ①/E/34 DU DS10- ①/10 NEE
① ① ① ①
- TB - TB
- TB02 - TB02
TC - TC -
TC002 - TC002 -
RK RK3) RK RK3)
RK002 RK023) Rk002 RK023)
1) For Piloting Please Use The Following NG6 Valves : 4/3 : DU DS3-S3…
4/2 ( RK ) : DU DS3-RK…
2) Different Transition Position As Shown, See Main Catalogue Of DUPLOMATIC For Reference .
Pmax. = 320 bar, Weight : NG 10 = 6.6 kg, Weight : NG 16 = 8.6 kg, Weight : NG 25 = 13.6 kg, Weight : NG 32 = 48.0 kg
A Check Valve In Port P Is Required For Internal Piloting Of Symbols S 2, S4, S7, S8, SA2, SA4, SB2, SB4. Order Codes On Reque
All Above Listed Valves Are Coming With 2 Plugs ( Extenal Piloting + External Drain ).
If Required Remove Plugs According To Your Application, Following The Instructions In The Main Catalogue Of DUPLOMATIC.
pcs kg
Accessories Description Order Coder ( 1 Box )
per box per box
Subplates NG 16
Side Entry 1" BSP
Pmax. = 320 bar 1 11.5 DU 1961111
Series :
MCD
Series :
MRQ
Series :
MZD
P Adj. Weight DU MZD ①/②/③/50
Symbol
( bar ) ( kg ) ① ②
3 - 35 2
10 - 70 3
1.4 -
30 - 140 4
50 - 280 5
3 - 35 2
10 - 70 3
1.4 /A
30 - 140 4
50 - 280 5
3 - 35 2
10 - 70 3
1.4 /B
30 - 140 4
50 - 280 5
③ : Omit For Hex Screw, " / M " For SICBLOCK Knob. Control On Otherside On Request.
Pmax. = 350 bar, Port T : Pmax. = 10 bar, Qmax. = 100 l/min ( Controlled Lines, Others 75 l/min ), P = 7 bar At 25 l/min
Series :
MSD
P Adj. Weight DU MSD ①/②/50
Symbol
( bar ) ( kg ) ①
10 - 70 3
30 - 140 1.4 4
50 - 280 5
Series :
PCM3
P Adj. Weight DU PCM3 - PTV/10N/①
Symbol
( bar ) ( kg ) ①
Series :
PBM3
25 2
S = Hex. Screw
70 1.6 3
K1 = Hand Knob
140 4
Series :
MERS
1.3 SA 1.3 D
1.3 SB 1.3 RD
② : Omit For Hex Screw Use " / M " For SICBLOC Knob
Pmax. = 350 bar, Check Valves Cracking Pressure : 0.5 bar
Qmax. = 50 l/min ( Controled Lines, Others 75 l/min )
Qmin. < = 0.060 l/min At P = 10 bar
Check Valves
With Flow Restrictor
NG 6 / Cetop 3
Series :
MVR - RS/P
Weight
Symbol Model
( kg )
Series :
RPC1*/M
Flow ① Weight DU RPC1- ①/M/②③/10 Flow ① Weight DU RPC1- ①/M/②③/10
Symbol Symbol
( l/min ) ( kg ) ② ( l/min ) ( kg ) ②
1 1
4 4
10 10
3.0 P 4.1 D
16 16
22 22
30 30
1 1
4 4
10 10
3.0 A 3.0 T
16 16
22 22
30 30
1 1
4 4
10 10
3.0 B 3.7 PCT3
16 16
22 22
30 30
③ : Omit For Hex Screw Use " / M1 " For Hand Knob
Pmax. = 250 bar, Qmax. As Per 1 ( Controled Lines, Free 65 l/min, Check Valve Lines 40 l/min )
Fast - Slow
Electric Control Valves
NG 6 / Cetop 3
Series :
RL1M
DU RL1M①-②/③/21/④/⑤ DU RL1M①-②/③/21/④/⑤
Flow Weight Voltage Flow Weight Voltage
Symbol ( l/min ) ( kg ) ④ Symbol ( l/min ) ( kg ) ④
② = -50 Hz ② = -50 Hz
① ③ 12 VDC 110 VAC ① ③ 12 VDC 110 VAC
24 VDC 230 VAC 24 VDC 230 VAC
1 1
4 D12 A110 4 D12 A110
10 10
3.0 A A 3.0 A A
16 16
22 D24 A230 22 D24 A230
30 30
1 1
4 D12 A110 4 D12 A110
10 10
3.0 T A 3.0 T A
16 16
22 D24 A230 22 D24 A230
30 30
⑤ : Omit For Standard, Use " CM " For Manual Override Protection
Pmax. = 250 bar, Qmax. As Per 2 ( For Controled Lines 65 l/min ) Qmin. < = 0.08 l/min
Check Valves
Direct Operated
NG 6 / Cetop 3
Series :
MVR
Cracking Cracking
DU MVR ①②/51 DU MVR ①②/51
( bar ) Weight ( bar ) Weight
Symbol Symbol
( kg ) ( kg )
① ② ① ②
SP SB
1 = 0.5
1
1 = 0.5 3 = 5.2
1 SA SPT
3 = 5.2
ST
Check Valves
Pilot Operated
NG 6 / Cetop 3
Series :
MVPP
Weight DU MVPP①/50
Symbol
( kg ) ①
SA
1.3 SB
Series :
RQ4M
Series :
Z4M
Sequence Valves
Direct Operated
NG 10 / Cetop 5
Series :
SD4M
Series :
ERS4M
3.1 SA 3.1 D
3.1 SB 3.1 RD
② : Omit For SICBLOC Knob, Use " S " For Hex Screw
Pmax. = 320 bar
Check Valve Cracking Pressure 0.5 bar
Qmax. = 80 l/min ( Controlled Lines, Others 100 l/min )
P ( " RD " At 50 l/min ) = 5.5 bar ( A - > A1, B - > B1 ) ; ( RD = Mer In )
Note : Rotate Clockwise To Increase Flow
Series :
RPC1*/4M
Pmax. = 250 bar, Qmax. As Per ( Controlled Lines, Free Lines : 100 l/min, Check Valve Lines 40 l/min )
Check Valves
Direct Operated
NG 10 / Cetop 5
Series :
VR4M
2.3 SP
1 = 0.5 bar
4 = 0.8 bar
2.3 ST
Check Valves
Pilot Operated
NG 10 / Cetop 5
Series :
VPP4M
Weight DU VPP4M - ① / 40
Symbol
( kg ) ①
7.2 SA
7.2 SB
7.3 D
Pmax. = 320 bar, Qmax. = 65 l/min ( Check Valve Others 100 l/min )
P ( " D " At 50 l/min ) = 4 bar ( A1 - > A, B1 - > B ), P = 8 bar ( A1, B - > B1 ), Area Ratio : 5.8 : 1
Series :
PRM7
15 - 160 4
15 - 250 8.5 5
15 - 350 6
Series :
PZM7
15 - 100 3
8.65 P
15 - 250 5
15 - 100 3
8.65 PA
15 - 250 5
③ : " S " For Hex Screw, " K " For Hand Knob
Pmax. = 350 bar, Qmax. = 250 l/min ( All Lines ), P = 17 bar At 200 l/min
Series :
QTM7
7.35 SA
7.7 D
Check Valves
Pilot Operated
NG 16 / Cetop 07
Series :
CHM7
7.2 SA
7.2 SB
7.3 D
Series :
PRED3
P Max Weight DU PRED3-①/10N - D24/K1
Symbol
( bar ) ( kg ) ①
20 V ( Nom. ) 070 = 0.7 - 70 bar
Pmax. = 350 bar ( 2 bar In " T " ), Qmin. = 1 l/min, Qmax. = 3 l/min
Hysteresis : < 5% Of Prange, Repeatability : < + 2% Of Prange
Series :
MZE
- - - 0.25 DU 1950751
Pmax. = 320 bar, Qmax. = 30 l/min ( Controlled Line, Others 50 l/min ), Qmax. = 0.6 l/min
Hysteresis : < 6% Of Prange, Repeatability : < + 2.5% Of Prange
Series :
RPCED1
Pmax. = 250 bar, Qmax. As Per ① ( Controled Line, Check Valve 40 l/min )
Pmin. = 10 bar
Hysteresis : < 6% Of Qrange, Repeatability : < + 2.5% Of Qrange
Series :
RPCED1-*-1T3
Pmax. = 250 bar, Qmax. As Per ① ( Controled Line, Check Valve 40 l/min )
Pmin. = 8 bar
Hysteresis : < 6% Qrange, Repeatability : < + 2.5% Of Qrange
Series :
RPCER1
1.5 1
4 4
20 V ( Nom. )
2.9
18.5 ( At 20 oC )
8 8
0.7 A ( Nom. )
16 16
Pmax. = 250 bar, Qmax. As Per ( Controled Line, Check Valve 40 l/min )
Pmin. = 10 bar
Hysteresis : < 2.5% Of Qrange, Repeatability : < + 1% Of Qrange
Series :
DSE3
C26
26 l/min 2 24 VDC
A26
Series :
DSE3G
26 l/min 2.4
Series :
PRED3G
Series :
DSE3F
16 l/min C16
1.9
26 l/min C26
Series :
D4E
Flow Rate ②
DU D4E①/41 - 24
P = 10 bar Weight
Symbol
(P-T) ( kg )
①
At
6.2 S12②
1 = 30 l/min
6.2 S9②
2 = 40 l/min
4.4 12②TA
3 = 50 l/min
4.4 12②TC
Series :
DSPE5
7.5 A80
80 l/min
7.1 C80SA
7.1 A80SB
Series :
DSPE7
9.7 A80
150 l/min
9.3 C80SA
9.3 A80SB
Series :
DSPE8
16 A80
300 l/min
15.6 C80SA
15.6 A80SB
Series :
DXJ3
Flow Rate
DU DXJ3 - D0L①/10N/E0K11
P = 10 bar Weight
Symbol
(P-T)
( kg ) ①
At
5 l/min 5
10 l/min 10
2.5
20 l/min 20
40 l/min 40
Series :
DXJ5
Flow Rate
DU DXJ3-D0L①/10N/E0K11
P = 10 bar Weight
Symbol
(P-T) ( kg )
①
At
60 l/min 60
6.3
100 l/min 100
Series :
EPC, EPA, EPR, UEIK EPC EPA , EPR UEIK
RPCED1, RPCED1*-*,
1 0.82 - DU EPC-110 DU EPA-M110/20 DU UEIK-11/51-24
RPCE2-*, RPCE3-*
Series :
EPR-P1, UEIK-PID
UEIK - PID
UFIK-2*RL
Function For Valve Types Order Code System Requirements
RPED DU EPR-P153/10E0
Closed Loop Pressure Control Pressure Valve, As Listed Pressure
MZE DU EPR P-154/10E0
Amplifier Transducer DU PT*/10E1-K10
RQE DU EPR-P152/10E0
DSE3 -
4/3 Prop. Dir. Contr. Valve Without
4 Speeds + Ramps Amplifier E4E-S*, E07E-S*, E5E-S* DU UEIK-21RL/51-24
Pos. Feedback As Listed
D4E-S* DU UEIK-22RL/51-24
4/3 Prop. Dir. Control Valve, Any
Analog Position Control All 4/3 Proportional Valves DU UEIK-PID/10-24 Type Position Transducer Valve
Amplifier
Plug Types
For Prop. Valves
Without Pos. Feedback
Series :
EPC
Power Supply : 10 VDC To 30 VDC, Input : 0 V To 10 V At 100, Electrical Connection : DIN 43650, Protection Class IP67
Series :
EPA
1 = 0.8 A 0 = 200 Hz
2 = 1.2 A
1 = 100 Hz 0.15 2
3 = 1.6 A
4 = 2.0 A 4 = 400 Hz
Series :
EPR
50 = RPCER1
52 = MD1ER-**T*
51 = MD1ER-S* 0.15 2
52 = RQE P1
53 = CDE For Closed Loop Pressure Control
54 = MZE ( Pessure Transducer
PT*/10E1 - K10 Required )
Eurocard Holders
Phoenix Contacts
Series :
SKBI32
Weight
Symbol DU SKBI32/D
( kg )
Weight
Symbol DU SKBI32/D
( kg )
Eurocared Types
For Proportional Valves
Series :
UEIK
1 Or 0.2
0 V To + 10 V
11 RSQ = With Valve Feedback
-
100 x 160 x 35 mm
Or 0.27
0 V To + 10 V
21 RSD = With Feedback
2 -
100 x 160 x 35 mm
4 mA To 20 mA Analog Position
Pressure Transducers
Series :
PTH
40 40
12 - 35 0 =0 V To 10 V
100 100
400 0.13
250 200
8 - 36 1 = 4 mA To 20 mA
400 400
Stainless Steel, IP65, Typical Total Error : < = + - 0.4% Of Range, Zero Adjustment
Connection : 1/4" BSP With Integrated Seal, Response Time 10 ms, Working Temperature Range : - 20 oC To + 180 oC
Pressure Switchs
Piston Types
Series :
PS
3 - 35 2 350 2.5
P = Subplate Or NG6 - Modular
Valve Block
6 - 140 6 350 4
0.67
10 - 350 4 650 9
20 - 630 8 650 20
Series :
CR
② : Omit For Hex Screw, For Handknob Use " K " Pmax. = 350 bar
Series :
CRQ
② : Omit For Hex Screw, For Handknob Use " M1 " Pmax. = 350 bar
Series :
PCK06
Series :
RM*-W
Flow Size DU RM① - ②/③/④ Adjustment
Symbol
( l/min ) ① P Adj. ② ③ ④
3 = 5 - 70 bar K = Adjustment Knob
50 2 = 3/8"
4 = 10 - 140 bar 31 = Size 2 For RM2-W
5 = 20 - 210 bar 30 = Size 3 M1 = Adjustment Knob
70 3 = 1/2"
6 = 10 - 350 bar For RM3-W
② : Omit For Hex Screw, For Handknob Use " M1 " Pmax. = 350 bar
Series :
RQ5-W
Flow Weight DU RQ5 - W①/②/41 Port Size
Symbol
( l/min ) ( kg ) P Adj. ① ② Inlet ( P ) Outlet ( T ) Remote ( X )
3 = 35 - 70 bar
250 4.1 5 = 35 - 210 bar M 3/4" BSP 1" BSP 1/4" BSP
6 = 35 - 350 bar
② : Omit For Hex Screw, For Handknob Use " M " Pmax. = 350 bar
Series :
RQM5-W
Flow DU RQM5 - W①/②/51- * Port Size
Symbol
( l/min ) P Adj. ( bar ) ① ② Inlet ( P ) Outlet ( T ) Remote ( X )
RQM5-W*/A
A
RQM5-W*/B 3 = 35 - 70
250 5 = 35 - 210 B 3/4" BSP 1" BSP 1/4" BSP
6 = 35 - 350
RQM5-W*/C
C
Series :
RQ*-P
③ : Omit For Hex Screw, For SICBLOCK Knob Use " M ", Pmax. = 350 bar
Series :
RQM*-P
④ : Omit For Hex Screw, For SICBLOCK Knob Use " M ", Pmax. = 350 bar
" * " For Electrical Supply Features 24 VDC Or 230 VAC
Series :
MRQA
③ : Omit For Hex Screw, For SICBLOCK Knob Use " M ", Pmax. = 350 bar, ④ = Check Valve Use " C ", Omit If Not Required
Series :
Z*P
Pressure Valves
Subplate Mounting
Series :
S*-P, U*-P, T*-P, X*-P
3 = NG 16 60 5.8
U*-P
S 4 = 10 - 35 bar
U
5 = 15 - 70 bar C
T*-P T
X 6 = 35 - 140 bar
5 = NG 25 150 6.7
X*-P
Remark :
S = Sequence Valve
U = Unloading Valve
T = Backpressure Valve
X = Balancing Valve
Maximum Operating Pressure 320 bar
④ = " C " Check Valve For Free Flow From U To E Cracking Pressure 0.5 bar ( Omit For Version Without Check Valve )
Unloading Valves
( For Circuit With Accumulator )
Subplate Mounting
Series :
RQR*- P, RQA*- P
Series :
RS*
Series :
RSN*
Series :
RPC1
Series :
RPC1-T3
Series :
RPC*
Cetop 06 Cetop 07
31
Size 2 Size 3 M = Single - Turn
2 = NG10 N = 22 N = 100 Adjustment Knob
C RC
3 = NG25 S = 38 S = 150 ( Omit For Six - Turn
70 = 70 Adjustment )
43
Remark :
② : Omit If Not Required, For Check Valve Use " C "
④ : RC = Compensating Stroke Governor ( Omit For Not Required )
⑥ : Series No. 31 For Size 2, Series No. 43 For Size 3
Check Valves
Threaded Type
Series :
VD*-W*
Check Valves
Subplate Mounting
Series :
VR*-P
Series :
VP*-W*-MU
Series :
VP*-P*-MU
Check Valves
Cartridge Type
Series :
VR*-I
Series :
GP
Remark :
SAE Flang Mounting GP1, GP2, GP3
" * " SAE Not Available
F : For Flange Connection
① ①
Pump Size Flange Code Flange Description Pmax. A Port B Port D
3 Bolt O - Ring
0771048 RPA1 - 038 3/8" BSP 30 12
GP1 M6 x 20 OR 121
0771049 RPA1 - 12 1/2" BSP 30 12
0771050 RPA2 - 12 1/2" BSP 40 20
GP2 M8 x 25 OR 132
0770615 RPA2 - 34 3/4" BSP 40 20
315
0771051 RPA3 - 34A 3/4" BSP 51 24
0770617 RPA3 - 100A 1" BSP 51 24
GP3 M10 x 30 OR 4118
0770618 RPA3 - 34B 3/4" BSP 56 24
0770619 RPA3 - 100B 1" BSP 56 24
Series :
DFP
R : Rotation Clockwise
① ②
Flange Code Flange Description A Port B Port Bolt Code
4 Bolt O - Ring Code
0610719 SAE - 3/4" 3/4" BSP 19 OR 4100
3/8" UNC x 1-1/2" 0530612
0610713 SAE - 1" 1" BSP 25 OR 4131
0610720 SAE - 1-1/4" 1-1/4" BSP 32 7/16" UNC x 1-1/2" 0530613 OR 4150
0610714 SAE - 1-1/2" 1-1/2" BSP 38 OR 4187
0610721 SAE - 2" 2" BSP 51 1/2" UNC x 1-3/4" 0530638 OR 4225
0610722 SAE - 2-1/2" 2-1/2" BSP 63 OR 4275
0610723 SAE - 3" 3" BSP 73 OR 4337
5/8" UNC x 2" 0530658
0610724 SAE - 3-1/2" 3-1/2" BSP 89 OR 4387
Variable Displacement
Vane Pumps Series 20
Series :
PVD
K : For Pressure Range 80 bar To 150 bar ( Only For PVD 9/13/17 )
Variable Displacement
Vane Pumps Series 30
Series :
PVA
Variable Displacement
Axial - Piston Pumps
Series :
VPPM
Max. Operated Pressure 280 bar And Peak Pressure 350 bar
Connection Flanges
SAE 3000
SAE 6000