Cálculos Parcial Abastecimiento
Cálculos Parcial Abastecimiento
Cálculos Parcial Abastecimiento
Hora
0:00 0.73 % Acumulado %
1:00 0.87 0 0.00% 0.00% 0.00%
2:00 0.93 1 0-1 3.02% 3.02% 4.17%
3:00 0.91 2 1-2 3.64% 6.66% 4.17%
4:00 1.05 3 2-3 3.88% 10.54% 4.17%
5:00 1.29 4 3-4 3.80% 14.34% 4.17%
6:00 1.18 5 4-5 4.38% 18.72% 4.17%
7:00 1.26 6 5-6 5.39% 24.11% 4.17%
8:00 1.49 7 6-7 4.92% 29.03% 4.17%
9:00 1.04 8 7-8 5.26% 34.29% 4.17%
10:00 1.29 9 8-9 6.21% 40.51% 4.17%
11:00 1.30 10 9-10 4.35% 44.86% 4.17%
12:00 1.04 11 10-11 5.39% 50.25% 4.17%
13:00 0.81 12 11-12 5.43% 55.68% 4.17%
14:00 0.91 13 12-13 4.35% 60.02% 4.17%
15:00 0.80 14 13-14 3.39% 63.41% 4.17%
16:00 1.18 15 14-15 3.78% 67.20% 4.17%
17:00 0.81 16 15-16 3.34% 70.54% 4.17%
18:00 1.17 17 16-17 4.91% 75.45% 4.17%
19:00 1.16 18 17-18 3.37% 78.82% 4.17%
20:00 0.94 19 18-19 4.88% 83.70% 4.17%
21:00 0.71 20 19-20 4.83% 88.53% 4.17%
22:00 0.45 21 20-21 3.90% 92.43% 4.17%
23:00 0.66 22 21-22 2.94% 95.37% 4.17%
23 22-23 1.89% 97.26% 4.17%
Suma 24.00 24 23-24 2.74% 100.00% 4.17%
Suministro Cambio en almacenamiento Volumen almacenamiento
Acumulado % Acumulado %
0.00% 0.00% 0.00%
4.17% 1.14% 1.14% 7.00%
8.33% 0.53% 1.67% 7.53%
12.50% 0.28% 1.96% 7.82%
16.67% 0.37% 2.33% 8.19%
20.83% -0.21% 2.11% 7.97%
25.00% -1.22% 0.89% 6.75% Consumo acumu
29.17% -0.76% 0.13% 5.99% 120.00%
33.33% -1.09% -0.96% 4.90%
37.50% -2.05% -3.01% 2.85% 100.00%
41.67% -0.18% -3.19% 2.67%
45.83% -1.23% -4.42% 1.44% 80.00%
Capacidad de regulación
Dato Valor Unidad
Caudal máximo diario QMD 36115 m3/d
Capacidad de regulación Cregulación m3
Capacidad de diseño
Dato Valor Unidad
Capacidad de almacenamiento 12038.40 m3
Dimensionamiento
Dato Notación Valor Unidad ℎ=𝑉/3+𝑘
Altura h 5.0 m
Lado L 53.8 m 𝐿𝑎𝑑𝑜=√(𝑉𝑜𝑙𝑢𝑚𝑒𝑛/𝐴𝑙𝑡𝑢𝑟𝑎)
Borde libre B. L. 0.3 m
Tanque circular
Volumen Diametro
14447 43
ℎ=𝑉/3+𝑘
𝑎𝑑𝑜=√(𝑉𝑜𝑙𝑢𝑚𝑒𝑛/𝐴𝑙𝑡𝑢𝑟𝑎)
Área total (ha) 11800
Caudal de diseño
348
(L/s)
Caudal específico
0.03
(L/s*ha)
Consumo (L/s)
0 0.2 52.4 262 400
5 10 15 20 25
Tiempo (Hora)