Curva de calibración

Abs 500 nm
Conc (ppm)
Medida 1 Medida 2 Promedio 1
50 0.0026 0.0015 0.0020
0.1
100 0.0063 0.0092 0.0078
0.09
200 0.0182 0.0182
0.08
300 0.0315 0.0176 0.0246 0.07
400 0.0321 0.0321 0.06
500 0.0496 0.0439 0.0468 0.05
600 0.0536 0.0573 0.0555 0.04
700 0.0591 0.0591 0.03
r2 0.9738 0.9708 0.9891 0.02
0.01
0
0 100 200 300 400 500 600

1 Linear (1)

Pendiente 0.00009
intercepto 0.0016

0.1000
Matriz Abs 500 nm 0.0900
Medida 1 Medida 2 0.0800
Hígado 0.1293 0.092 0.11065 0.0700
Molleja 0.1024 0.0726 0.0875 0.0600
f(x) = 9.0699

Axis Title
Corazón 0.0707 0.0483 0.0595 0.0500 R² = 0.98910
0.0400

Curva PROM 0.0300


0.0200
Concentración
Muestra PROM 0.0100
(ppm)
0.0000
Higado 1 1454.4 0 100 20
1247.22
Higado 2 1040.0
Molleja 1 1155.6
990.00
Molleja 2 824.4
Corazón 1 803.3
678.89
Corazón 2 554.4
1
2
0.1
0.09
0.08
0.07
0.06
0.05
0.04
0.03
0.02
0.01
400 500 600 700 800 0
0 100 200 300 400 500 600 700 800
Linear (1)
2 Linear (2)

PROM
0.1000
0.0900
0.0800
0.0700
0.0600
f(x) = 9.06997578692494E-05 x − 0.0015680387409201
0.0500 R² = 0.989103358569591
0.0400
0.0300
0.0200
0.0100
0.0000
0 100 200 300 400 500 600 700 800
Axis Title
700 800
Curva de calibración
Abs 490 nm
Conc (ppm)
Medida 1 Medida 2 Promedio 1
10 0.0004 0.0750 0.0377
20 0.0510 0.0835 0.6
0.0673
30 0.1277 0.1410 0.1344
40 0.2050 0.1735 0.5
0.1892
50 0.2168 0.3081 0.2624
60 0.3113 0.2690 0.2902 0.4

70 0.3733 0.3364 0.3549


80 0.3848 0.3848 0.3

90 0.3994 0.4748 0.4371


100 0.5330 0.5474 0.5402 0.2

r2 0.9736 0.9635 0.9902 0.1

0
0 20 40 60 80
Pendiente 0.0054
intercepto 0.0265 1 Linear (1)

Matriz Abs 490 nm


Medida 1 Medida 2

Piña 0.2250 0.22643 0.2257


Coca cola 0.3700 0.2540 0.3120

Curva PROM

Muestra Concentración (ppm) PROM

P1 46.6
46.71
P2 46.8
C1 73.4
62.69
C2 51.9
1
2
0.6000

0.5000

0.4000

0.3000

0.2000

0.1000

40 60 80 100 120 0.0000


0 20 40 60 80 100 120
1 Linear (1)
2 Linear (2)

PROM
0.6000

0.5000
f(x) = 0.00538678787878788 x − 0.0264633333333333
R² = 0.990197987535118
0.4000
Axis Title

0.3000

0.2000

0.1000

0.0000
0 20 40 60 80 100 120
Axis Title
80 100 120

ear (2)
Curva de calibración
Abs 790 nm
Conc (ppm)
Medida 1 Cálculo
1
0 0 0
50 0.0037 0.00185 0.0600
25
f(x) = 0.000163285714285714 x + 0.000921428571428573
100 0.0094 0.0047 50 R² = 0.970892884745722
0.0500
150 0.0110 0.0055 75
200 0.0276 0.0138 100
0.0400
250 0.0343 0.01715 125
300 0.0405 0.02025 150 0.0300
350 0.0514 0.0257 175
0.0200

0.0100
r2 0.9709 0.9709
0.0000
0 50 100 150 200 250 300

Medida 1 1 Linear (1) Linea


Pendiente 0.0002 Linear (1) Linear (1)

intercepto 0.0009
Cálculo
Pendiente 0.00008
intercepto 0.0005
Matriz Abs 790 nm
Medida 1 Medida 2 Curva 1
Concentración
Muestra
(ppm)
Tomate 0.0034 0.0045 0.0039 C1 10.5
Café 0.0030 0.0037 0.0034 C2 14.0
T1 12.5
T2 18.0
Cálculo
0.03
28571428573
0.025
f(x) = 0.000163285714285714 x − 0.00362142857142857
R² = 0.970892884745722
0.02

0.015

0.01

0.005

0
00 250 300 350 400 0 20 40 60 80 100 120 140 160 180 200

Linear (1) Linear (1) 1 Linear (1) Linear (1)


Linear (1) Linear (1) Linear (1)

rva 1 Cálculo

PROM Muestra Concentración (ppm) PROM

C1 31.2
12.25 35.625
C2 40.0
T1 36.2
15.25 43.125
T2 50.0
7142857